HomeMy WebLinkAboutOrdinance 310 Adoption of 2013 CA Building CodeOrdinance No. 310
An Ordinance Adopting the 2013 California Building, Residential Building,
Electrical, Mechanical, Plumbing, Fire, Energy, and Green Building Standards Codes
with Modifications for Local Conditions and Making Certain Other Amendments to
Chapter 16 (Building Regulations) of the City Code
THE CITY COUNCIL OF THE CITY OF SARATOGA DOES ORDAIN AS
FOLLOWS:
Section 1. Findings.
The City Council finds and declares as follows:
A. The State of California has adopted the 2013 California Building Standards Code
(California Code of Regulations, Title 24, Part 2, Volumes 1 and 2, based upon the
2012 International Building Code as published by the International Code Council);
the 2013 California Residential Building Code (California Code of Regulations,
Title 24, Part 2.5, based upon the 2012 International Residential Code as
published by the International Code Council); the 2013 California Electrical Code
(California Code of Regulations, Title 24, Part 3, based on the 2011 National
Electrical Code as published by the National Fire Protection Association); the
2013 California Mechanical Code (California Code of Regulations, Title 24, Part
4, based on the American National Standard 2012 Uniform Mechanical Code); the
2013 California Plumbing Code (California Code of Regulations, Title 24, Part 5,
based on the American National Standard 2012 Uniform Plumbing Code); the 2013
California Energy code (California Code of Regulations, Title 24, Part 6); the 2013
California Fire Code (California Code of Regulations, Title 24, Part 9, based on
the 2012 International Fire Code as published by the International Code Council);
and the 2013 California Green Building Standards Code (California Code of
Regulations, Title 24, Part 11). These Codes shall hereinafter be referred to
collectively as the "Building Codes."
B. On November 20, 2013, pursuant to California Government Code Section
50022.3, the City Council of Saratoga conducted a first reading of the title of the
ordinance adopting the Building Codes and of the codes to be adopted thereby
and scheduled a public hearing on the adoption of the Building Codes, to be held
December 4, 2013.
C. On November 19, 2013, pursuant to California Government Code Section
50022.6, at least one copy of the primary codes certified as true copies by the
legislative clerk were filed with the legislative clerk for public inspection.
1
D. On November 20, 2013, pursuant to California Government Code Sections
50022.3 and 6066, a notice was published in a newspaper of general circulation
stating the time and place of the December 4, 2013, public hearing and including
a description the legislative body deemed sufficient to give notice of the purpose
and subject matter of said ordinance. The notice informed the public that copies
of the primary codes considered for adoption were on file with the clerk of the
legislative body and open for public inspection.
E. On November 27, 2013, pursuant to California Government Code Sections
50022.3 and 6066, a second notice identical to the first was filed in a newspaper
of general circulation.
F. On December 4, 2013, pursuant to California Government Code Section 50022.4, a
public hearing was held. Following public testimony and consideration, the City
Council of Saratoga found that adoption of the Building Codes was in the public
interest. Except as to the additions, deletions, and amendments hereinafter noted,
the Building Codes are hereby adopted and made a part hereof, the same as if fully
set forth in this Article, and shall be the Building Regulations of the City.
G. Additions, deletions, and amendments similar to those adopted in the City of
Saratoga's 2010 Building Regulations were and are deemed reasonably necessary
because of local climatic, geological, or topographical conditions pursuant to
Government Code Section 17958.5. Express findings that these modifications to
the Building Code were reasonably necessary were filed upon the adoption of the
City of Saratoga's 2010 Building Regulations with the California Building
Standards Commission in accordance with California Health and Safety Code
Section 17958.7 and are available as a public record.
H. The new additions, deletions, and amendments hereinafter noted are deemed
reasonably necessary because of local climatic, geological, or topographical
conditions pursuant to Government Code Section 17958.5. Express findings that
these modifications to the Building Code are reasonably necessary will be filed
with the California Building Standards Commission in accordance with California
Health and Safety Code Section 17958.7 before this ordinance takes effect.
I. While the ordinance codified in this Article is in force, a true copy of the Building
Codes shall be kept for public inspection in the office of the Building Official and
a reasonable supply of the Building Code shall be available for public purchase in
the office of the City Clerk in accordance with Government Code Section 50022.6.
E
Section 2. Adoption.
Article 16 -15 of the Saratoga City Code concerning the Building Code is hereby
deleted in its entirety and replaced with Article 16 -15 attached in Appendix A.
Article 16 -18 of the Saratoga City Code concerning the Residential Building Code
is hereby adopted as attached in Appendix A.
Article 16 -20 of the Saratoga City Code concerning the Fire Code is hereby deleted
in its entirety and replaced with Article 16 -20 attached in Appendix A.
Article 16 -25 of the Saratoga City Code concerning the Plumbing Code is hereby
deleted in its entirety and replaced with Article 16 -25 attached in Appendix A.
Article 16 -30 of the Saratoga City Code concerning the Mechanical Code is hereby
deleted in its entirety and replaced with Article 16 -30 attached in Appendix A.
Article 16 -35 of the Saratoga City Code concerning the Electrical Code is hereby
deleted in its entirety and replaced with Article 16 -35 attached in Appendix A.
Article 16 -49 of the Saratoga City Code concerning the Green Building Standards
Code is hereby adopted as shown in Article 16 -49 attached in Appendix A.
Article 16 -51 of the Saratoga City Code concerning the Energy Code is hereby adopted
as shown in Article 16 -51 attached in Appendix A.
Section 16- 60.030 of the Saratoga City Code concerning the Early Warning Alarm
System alarm system requirement is amended to include the bold underlined exam le
text below:
16- 60.030 Plan check by Fire District.
(a) All documentation relative to the proposed installation shall be submitted to
the Fire District for approval. Where property is located within the jurisdiction of
the Central Fire District, one copy of such documentation shall be furnished to the
Chief of such District and one copy of such documentation shall also be furnished
to the Chief of the Saratoga Fire District who shall determine whether the
installation will comply with the applicable standards for the proposed system. The
documentation shall include all plans, specifications, diagrams, data sheets,
manufacturer's recommendations, and other information and documents listed in
the standards and requirements adopted by the Saratoga Fire District, and such
additional items pertaining to the proposed system as may be requested by the
District. Notwithstanding any other provisions of this Code, alternatives to the
adopted standards and requirements may be approved if the Chief of the Fire
District having jurisdiction over the property where an alternative is to be
installed determines that such alternative will perform the early warning
notification function as well or better than the adopted standards. The
3
Saratoga sire District shall be furnis ied a CORY of documentation f01- all
approved alternate installations.
(I b) The Fire Districts may establish a fee for the plan checking services
rendered pursuant to this Section.
Section 16- 75.010 of the Saratoga City Code concerning swimming pool fencing is
deleted as shown below:
Section 16- 75.030 of the Saratoga City Code concerning water conservation devices is
deleted as shown below:
:• :-
:
Lan FA :•
:• :
Ell
:
Mr. Mom I EM.".
:
-
-
.
:-
:
:
-:
•:
MAO.
-
:-
•:
:
•:
•:
-:
:•
:::
:.
Section 16- 75.030 of the Saratoga City Code concerning water conservation devices is
deleted as shown below:
Section 3. California Environmental Quality Act.
Pursuant to the California Environmental Quality Act ( "CEQA "), this action is
:• :-
:
Lan FA :•
:• :
WA
Section 3. California Environmental Quality Act.
Pursuant to the California Environmental Quality Act ( "CEQA "), this action is
exempt under California Code of Regulations, Title 14, Section 15308 (the amendments are
exempt because they assure maintenance, restoration, enhancement, or protection of the
environment) and Section 15061(b)(3) (the amendments are exempt because it can be seen
with certainty that there is no possibility that the activity in question may have a significant
effect on the environment).
Section 4. Severance Clause.
The City Council declares that each section, sub - section, paragraph, sub - paragraph,
sentence, clause, and phrase of this ordinance is severable and independent of every other
section, sub - section, sentence, clause, and phrase of this ordinance. If any section, sub-
section, paragraph, sub - paragraph, sentence, clause, or phrase is held invalid, the City
Council declares that it would have adopted the remaining provisions of this ordinance
irrespective of the portion held invalid and further declares its express intent that the
remaining portions of this ordinance should remain in effect after the invalid portion has
been eliminated.
M
Section 5. Publication.
This ordinance or a comprehensive summary thereof shall be published in a
newspaper of general circulation of the City of Saratoga within fifteen days after its
adoption.
- Continued Next Page -
4
The foregoing ordinance was introduced and read at the regular meeting of the City- Council
of the City of Saratoga held on the 20(h day of November, 2013, and was adopted by the
following vote following a second reading on the 4th day of December, 2013:
COUNCIL MEMBERS:
AYES: Mayor Emily Lo, Vice Mayor Howard Miller, Council Member Manny
Cappello, Chuck Page, Jill Hunter
NOES: None
ABSENT: None
ABSTAIN: None
Emily Lo
MAYOR, CITY OF SARATOGA, CALIFORNIA
ATTEST:
c DATE: i
ryst 1 Bothelio
C� CLERK
APPROVED AS TO FORM:
Richard Taylor
CITY ATTORNEY
DATE:
5
t216) [3
APPENDIX A
The City of Saratoga Municipal Code Chapter 16 Building Regulations is amended as follows.
Only the sections of Chanter 16 listed below are modified. All other sections not modified with
this ordinance shall remain in effect:
16- 15.010 Adoption of 2013 California Building Code.
(a) The 2013 California Building Code, Title 24, Part 2, Volume 1 and 2, including
appendices F and I, referred to throughout this Chapter as the "Building Code," is
hereby referred to and, except as to additions, deletions and amendments hereinafter
noted, such code is hereby adopted and made a part hereof, the same as if fully set forth
in this Article, and shall be the Building Code of the City. However, in accordance with
California Government. Code Section 50222.4, no penalty clauses are adopted by
reference. In accordance with California Health and Safety Code Section 17958.7,
express findings that modifications to the Building Code are reasonably necessary
because of local climatic, geological, or topographical conditions are either already on file
with the California Building Standards Commission or will be filed prior to the effective
date of the ordinance codified in this Article.
(b) In accordance with California Government Code Section 50022.6, at least one true
copy of the Building Code has been on file with the City Clerk since fifteen days prior to
enactment of the ordinance codified in this Article. While the ordinance codified in this
Article is in force, a true copy of the Building Code shall be kept for public inspection in
the office of the Building Official. A reasonable supply of the Building Code shall be
available in the office of the City Clerk for public purchase.
(c) The additions, deletions and amendments set forth in this Article are made to the
Building Code, as adopted by reference in Section 16- 15.010(a).
16- 15.020 Enforcement of Title 24 of the California Code of Regulations.
Pursuant to the laws of the State of California, Title 24 of the California Code of
Regulations, also known as the California Building Standards Code, applies to all
construction in the State of California and is enforced by the City of Saratoga in
accordance with State law. This and other Articles of Chapter 16 of the Saratoga Code
adopt certain provisions of Title 24 by reference and make revisions to reflect local
climatic, geological, or topographical conditions. The provisions of Title 24 that are not
adopted by reference or amended by this Article remain in effect as laws of the State.
16- 15.025 Retention of plans.
(a) Section 107.5 of the Building Code is amended to read:
107.5 Retention of plans. One set of reviewed plans and specifications shall be
returned to the applicant and shall be kept on the site of the building or work at all times
during which the work authorized thereby is in progress. One set of reviewed plans,
specifications, and computations shall be retained by the building official as part of his
permanent records.
16.15 -030 Expiration of permits.
(a) Subsection 105.5 of the Building Code is amended to read:
105.5 Expiration of Permits.
(a) Every permit issued by the building official under the provisions of the Building
Code shall expire by limitation and become null and void if any one of the
following occurs:
(1) The building or work authorized by such permit is not commenced within
180 days from the date of such permit; or
(2) The building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days;
or
(3) The permittee fails or refuses to request an inspection required by Section
110 of the Building Code within any period of 180 consecutive days after the
work authorized by the permit is commenced. If the building official conducts
such inspection within such 180 -day period, but declines to approve such
inspection without correction of specified items and subsequent re- inspection,
then the building permit shall not expire if such correction is made and passes
re- inspection within 30 days after the end of the 180 -day period described in
this subsection.
(b) After such expiration, such work can be recommenced only upon reinstatement or
issuance of a new permit to do so. The plans and specifications for a reinstated permit or
new permit shall comply with all provisions of the City building code in effect at the time
of reinstatement or issuance of a new permit. A reinstatement or new permit may be
issued as follows:
(1) Reinstatement. Expired Permits may be reinstated if an application for permit
reinstatement within 180 days of expiration, provided no changes have been
made or will be made in the original plans and specifications for such work,
and provided further that such suspension or abandonment under
(a)(2) above has not exceeded one year. The fee for issuance of a renewed
permit shall be one -half of the full permit fees (based upon the fee schedule
adopted by the City Council as of the time the reinstated permit is issued) if
the reinstated permit is applied for within 180 days after expiration of the prior
permit.
(2) New Permit. A new permit may be issued following expiration of a building
permit as follows. An applicant may apply for a new permit at any time so long
as any underlying Design Review Approval, Use Permit, or other required
planning approval remains effective. The full permit fee shall apply to the new
permit (based upon the fee schedule adopted by the City Council as of the
time the new permit is issued).
(c) Notwithstanding the foregoing provisions, upon written request by the applicant
showing, to the satisfaction of the building official, that the prior permit expired as a
result of exceptional circumstances beyond the reasonable control of the applicant, the
building official may waive or reduce the payment of a fee for issuance of the reinstated
or new permit.
(d) The building official may decline to issue more than one reinstatement of a building
permit if in the judgment of the building official the work authorized by the original permit
is not being diligently prosecuted to completion. The building official may also condition
any reinstatement to assure diligent prosecution to completion or to prevent a nuisance.
The building official may approve no more than two reinstatements of a building permit.
(e) The building official may at any time exercise discretion to find that a building, structure,
or work for which a building permit has expired qualifies as an unsafe building,
structure, or work and proceed to abate any nuisance associated therewith.
(f) Where: (i) a building permit has expired; and (ii) the building, structure, or other work
authorized by such permit has not been completed; and (iii) no reinstated permit has
been obtained within 180 days after expiration, then said building, structure, or work
shall be conclusively presumed to be unsafe; abandoned; a hazard to the public health,
safety, and welfare; and a public nuisance.
(g) The building official is authorized to exercise discretion to abate any public nuisance
regarding any unsafe building, structure, or work (including but not limited to one
resulting under the preceding paragraph) by repair, rehabilitation, demolition, or removal
thereof by:
(1) Proceeding under the Building Code for the Abatement of Dangerous
Buildings (Article 16 -45); or
(2) Proceeding under the following alternative method of enforcement where a
building, structure, or other work authorized by a building permit has not been
completed within 36 months of the date of issuance of the original permit, the
building official may abate such public nuisance by ordering and duly
enforcing repair, rehabilitation, demolition, or removal of the building,
structure, or other work; or construction of a fence or wall around the building,
structure, or work so as to obscure it from view; or construction of other
structures or blockades to prevent access to the building, structure, or other
work by animals or humans.
16.15 -040. Fees.
(a) Subsection 109.2 of the Building Code is amended to read:
109.2 Fees. The City of Saratoga may prescribe fees to defray the cost of enforcement of
rules and regulations promulgated by the Department of Housing and Community
Development or set forth in the Building Code. The amount of such fees shall not exceed
the amount reasonably necessary to administer or process permits, certificates, forms, or
other documents or to defray the costs of enforcement and shall be established by
resolution of the City Council. The payment of any fee shall not exempt any person from
compliance with all other provisions of this code or the technical codes nor from any
penalty prescribed by law.
Permit Fees. The amount of the fees to be paid for each permit shall be
established by resolution of the City Council.
Investigation Fees. Whenever any work for which a permit is required by this
code has been commenced without first obtaining said permit, a special
investigation shall be made before a permit may be issued for such work. An
investigation fee, in addition to the permit fee, shall be collected whether or not a
permit is then or subsequently issued. The investigation fee shall be established
by resolution of the City Council.
Plan Review Fees. When a plan or other data are required to be submitted by
Section 107.1 of the Building Code, a plan review fee shall be paid at the time
of submitting plans and specifications for review. Said plan review fee shall be
established by resolution of the City Council. Where plans are incomplete or
changed so as to require additional plan review, an additional plan review fee
shall be charged as established by resolution of the City Council.
Expiration of Plan Review. Applications for which no permit is issued within 180
days following the date of application shall expire by limitation, and plans and
other data submitted for review may thereafter be returned to the applicant or
destroyed by the building official. The building official may extend the time for
action by the applicant for a period not exceeding 180 days on request by the
applicant showing that circumstances beyond the control of the applicant have
prevented action from being taken. No application shall be extended more than
once. In order to renew action on an application after expiration, the applicant
shall resubmit plans and pay a new plan review fee.
Additional Fees. The City of Saratoga may prescribe any additional fees
reasonably necessary to cover the cost of administering this Article. Such fees
shall be set forth in the City of Saratoga Master Fee Schedule adopted by the
City Council.
16.15 -045. Roof coverings.
(a) Section 1505.1.3 of the Building Code is amended to read:
Roof coverings within all other areas. The entire roof covering of every
existing structure where more than 50 percent of the total roof area is replaced within
any one -year period; the entire roof covering of every new structure; and any roof
covering applied in the alteration, repair, or replacement of the roof of every existing
structure shall be a fire - retardant roof covering that is at least Class A.
(b) Section 1505.1.4 of the 2010 California Building Code is amended to read:
Roofing coverings within the Wildland -Urban Interface Fire Area. The
entire roof covering of every existing structure where more than 50 percent of the total
roof area is replaced within any one -year period; the entire roof covering of every new
structure; and any roof covering applied in the alteration, repair, or replacement of the
roof of every existing structure shall be a fire - retardant roof covering that is at least
Class A and must also comply with section 705A of the Building Code.
16- 15.050 Underside of appendages.
(a) Section 707A.8 of the Building Code is amended to read:
707A.8 Underside of appendages. The underside of overhanging appendages shall be
enclosed to grade in accordance with the requirements of Chapter 7 of the Building Code
or the underside of the exposed underfloor shall consist of one of the following:
1. Noncombustible material;
2. Ignition- resistant material;
3. One layer of 5/8 -inch Type X gypsum sheathing applied behind an exterior
covering on the underside of the floor projection;
4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to
the underside of the floor including assemblies using the gypsum panel and
sheathing products listed in the Gypsum Association Fire Resistance Design
Manual; or
5. The underside of a floor assembly that meets the performance criteria in
accordance with the test procedures set forth in SFM Standard 12 -7A -3.
Exception: Heavy timber structural columns and beams do not require protection.
16- 15.055 Accessory structures.
(a) Sections 710A.3.1 and 710A.3.2 of the Building Code are deleted in their entirety.
(b) Section 710AA of the Building Code is amended to read:
710A.4 Requirements. Accessory structures shall be constructed of noncombustible or
ignition- resistant materials.
16 -15 -060 Automatic Sprinkler Systems
Section 903.2 of the Building Code is amended to read:
903.2 Where required. Approved automatic sprinkler systems in new and existing
buildings and structures shall be provided in the locations described in this Section or in
Sections 903.2.1 through 903.2.18 of the Building Code, whichever is the more
restrictive. For the purposes of
this section, firewalls and fire barriers used to separate building areas shall be
constructed in accordance with the California Building Code and shall be without
openings or penetrations.
1. In buildings other than residential buildings, which require the installation of fire
sprinklers for all new buildings according to the California Residential Code, an
automatic sprinkler system shall be provided throughout all new non - residential
buildings and structures.
Exceptions:
a. Buildings and structures that do not exceed 1,000 square feet of building area and
that are not located in the Wildland -Urban Interface Fire Area.
b. Buildings and structures that are located in the Wildland -Urban Interface Fire Area
and do not exceed 500 square feet of building area.
c. Group S -2 or U occupancies that are not located in the Wildland -Urban
Interface and are used exclusively for vehicle parking and that meet all of the
following conditions:
i. Noncombustible construction;
ii. Maximum building area does not exceed 5,000 square feet;
iii. Structure is open on three (3) or more sides; and
iv. Minimum of 10 feet separation from existing buildings unless area
is separated by fire walls complying with Section 706 of the Building
Code.
2. An automatic sprinkler system shall be provided throughout existing buildings and
structures when alterations or additions are made that create conditions described in
Sections 903.2.1 through 903.2.18 of the Building Code.
3. An automatic sprinkler system shall be provided throughout existing buildings and
structures when additions are made that increase the building area to more than 3,600
square feet.
Exception:
One or more additions made to a building after January 1, 2011, that do not total more
than 1,000 square feet of building area.
4. An automatic sprinkler system shall be provided throughout all new basements
regardless of size and throughout existing basements that are expanded by more than
50 %.
5. Any change in the character of occupancy or in use of any building with a building
area equal to or greater than 3,600 square feet that, in the opinion of the fire code official
or building official, would place the building into a more hazardous division of the same
occupancy group or into a different group of occupancies and constitutes a greater
degree of life safety or increased fire risk, as defined herein, shall require the installation
of an approved fire automatic fire sprinkler system.
a. Life Safety — Increased occupant load, public assembly areas, public meeting areas,
churches, indoor amusement attractions, buildings with complex exiting systems due to
increased occupant loads, large schools /day -care facilities, large residential care
facilities with non - ambulatory patients.
b. Fire Risks — High -piled combustible storage, woodworking operations, hazardous
operations using hazardous materials, increased fuel loads (storage of moderate to
highly combustible materials), increased sources of ignition (welding, automotive repair
with the use of flammable liquids and open flames).
16- 18.010 Adoption of 2013 California Residential Building Code.
(a) The 2013 California Residential Building Code, Title 24 part 2.5, , referred to
throughout this Chapter as the "Residential Building Code," is hereby referred to and,
except as to additions, deletions, and amendments hereinafter noted, such code is
hereby adopted and made a part hereof, the same as if fully set forth in this article, and
shall be the Residential Building Code of the City. However, in accordance with
California Government Code Section 50222.4, no penalty clauses are adopted by
reference. In accordance with California Health and Safety Code Section 17958.7,
express findings that modifications to the California Building Standards Code are
reasonably necessary because of local climatic, geological, or topographical conditions
are either already on file with the California Building Standards Commission or will be
filed prior to the effective date of the ordinance codified in this Article.
(b) In accordance with California Government Code Section 50022.6, at least one true
copy of the Residential Building Code has been on file with the City Clerk since fifteen
days prior to enactment of the ordinance codified in this Article. While the ordinance
codified in this Article is in force, a true copy of the Residential Building Code shall be
kept for public inspection in the office of the Residential Building Official. A reasonable
supply of the Residential Building Code shall be available in the office of the City Clerk
for public purchase.
(c) The additions, deletions, and amendments set forth in this Article are made to
the Residential Building Code, as adopted by reference in Section 16- 18.010(a).
16- 18.020 Enforcement of Title 24 of the California Code of Regulations.
(a) Title 24 of the California Code of Regulations, also known as the California Building
Standards Code, is in effect in the City of Saratoga as amended by this Article. The
provisions of Title 24 that are not adopted by reference or amended by this Article are
enforced by the City of Saratoga as laws of the State.
16- 18.025 Automatic sprinklers.
(a) Section R313.1 is amended to read:
R313.1 Townhouse automatic fire sprinkler systems. An automatic residential fire
sprinkler system shall be installed in all new townhouses and in existing townhouses
when additions are made that increase the building area to more than 3,600 square feet.
Exception: One or more additions made to a building after January 1, 2011, that do not
total more than 1,000 square feet of building area.
(b) Section R313.2 is amended to read:
R313.2 One- and two- family dwellings automatic fire sprinkler systems. An
automatic residential fire sprinkler system shall be installed in one- and two - family
dwellings as follows:
1. In all new one- and two - family dwellings and in existing one- and two - family dwellings
when additions are made that increase the building area to more than 3,600 square feet.
Exception: One or more additions made to a building after January 1, 2011, that do not
total more than 1,000 square feet of building area.
2. In all new basements and in existing basements that are expanded.
Exception: Existing basements that are expanded by not more than 50 %.
16- 18.030 Material and construction methods for exterior wildfire exposure.
(a) Section R327.7.9 "Underside of appendages" is amended as follows: Delete "When
required by the enforcing agency."
(b) Section R327.10.3.2 is deleted in its entirety.
(c) Section R327.10.4 is amended as follows: Delete "When required by the enforcing
agency."
16- 18.035 Seismic reinforcing.
(a) Section R403.1.3 is amended to read:
R403.1.3 Seismic reinforcing. Concrete footings located in Seismic Design Categories
D0, D1, and D2, as established in Table R301.2(1) of the Residential Building Code,
shall have minimum reinforcement of at least two continuous longitudinal reinforcing
bars, one top and one bottom and not smaller than No. 4 bars. Bottom reinforcement
shall be located a minimum of 3 inches (76 mm) clear from the bottom of the footing.
In Seismic Design Categories D0, D1, and D2, where a construction joint is created
between a concrete footing and a stem wall, a minimum of one No. 4 bar shall be
installed at not more than 4 feet (1,219 mm) on center. The vertical bar shall extend to 3
inches (76 mm) clear of the bottom of the footing, have a standard hook, and extend a
minimum of 14 inches (357 mm) into the stem wall.
In Seismic Design Categories D0, D1, and D2, where a grouted masonry stem wall is
supported on a concrete footing and stem wall, a minimum of one No. 4 bar shall be
installed at not more than 4 feet (1,219 mm) on center. The vertical bar shall extend to 3
inches (76 mm) clear of the bottom of the footing and have a standard hook.
In Seismic Design Categories D0, D1, and D2 masonry stem walls without solid
grout and vertical reinforcing are not permitted.
Exception: In detached one- and two - family dwellings that are three stories or less in
height and constructed with stud bearing walls, isolated plain concrete footings
supporting columns or pedestals are permitted.
16- 18.040 Limits on methods Gypsum Board (GB) and Portland Cement Plaster (PCP).
(a) Table R602.10.3 (3) is amended as follows:
Add a new footnote "e" to the end of Table R602.10.3 (3), to read:
e. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted and
the use of Method PCP is limited to one -story single family dwellings and accessory
structures.
Add the "e" footnote notation in the title of Table R602.10.3 (3) to read:
TABLE R602.10.3 (3)e
(b) Section R602.10.4.4 is added to read:
R602.10.4.4 Limits on methods GB and PCP. In Seismic Design Categories D0, D1,
and D2, Method GB is not permitted for use as intermittent braced wall panels, but
gypsum board is permitted to be installed when required by this Section to be placed on
the opposite side of the studs from other types of braced wall panel sheathing. In
Seismic Design Categories D0, D1, and D2, the use of Method PCP is limited to one-
story single family dwellings and accessory structures.
16- 18.045 Roof classification.
(a) Section R902.1.3 is amended to read:
R902.1.3 Roof coverings in all other areas. The entire roof covering of every existing
structure where more than 50 percent of the total roof area is replaced within any one -
year period; the entire roof covering of every new structure; and any roof covering
applied in the alteration, repair, or replacement of the roof of every existing structure
shall be a fire - retardant roof covering that is at least Class A.
(b) Section R902.1.4. is amended to read:
R902.1.4.1 Roofing coverings within the Wildland -Urban Interface Fire Area. The
entire roof covering of every existing structure where more than 50 percent of the total
roof area is replaced within any one -year period; the entire roof covering of every new
structure; and any roof covering applied in the alteration, repair, or replacement of the
roof of every existing structure shall be a fire - retardant roof covering that is at least
Class A.
16- 20.010 - Adoption of the California Fire Code and International Fire Code.
The 2013 California Fire Code, Title 24 part 9, and the 2012 International Fire Code,
including Appendix
Chapters B, C, and K are referred to and, except as to additions, deletions, and
amendments hereinafter noted, are adopted and made a part hereof, the same as if fully
set forth in this Article. The California Fire Code and the International Fire Code as
adopted herein are hereinafter referred to collectively as the "Fire Code." However, in
accordance with California Government Code Section 50222.4, no penalty clauses are
adopted by reference. In accordance with California Health and Safety Code Section
17958.7, express findings that modifications to the California Building Standards Code
are reasonably necessary because of local climatic, geological or topographical
conditions are either already on file with the California Building Standards Commission,
or will be filed prior to the effective date of the ordinance codified in this Article. In
accordance with California Government Code Section 50022.6, at least one true copy of
the Fire Code has been on file with the City Clerk since fifteen days prior to enactment of
the ordinance codified in this Article. While the ordinance codified in this Article is in
force, a true copy of the Fire Code shall be kept for public inspection in the office of the
City Building Official and the Chief. A reasonable supply of the Fire Code shall be
available in the office of the City Clerk for public purchase.
16- 20.015 Enforcement of Title 24 of the California Code of Regulations.
Pursuant to the laws of the State of California, Title 24 of the California Code of
Regulations, also known as the California Building Standards Code, applies to all
construction in the State of California and is enforced by the City of Saratoga in
accordance with State law. This and other Articles of Chapter 16 of the Saratoga Code
adopt certain provisions of Title 24 by reference and make revisions to reflect local
climatic, geological, or topographical conditions. The provisions of Title 24 that are not
adopted by reference or amended by this Article remain in effect as laws of the State.
16- 20.020 - Fire Department and Chief.
Fire protection is provided in the City of Saratoga by the Santa Clara County Fire
Department and the Saratoga Fire District. As used in the Fire Code, "Fire Department"
refers to the Fire Department that provides fire protection to the relevant location, and
"Chief" or "Fire Code Official" refers to the Chief of that Fire Department.
16- 20.025 - Amendments to Chapter 57 of the Fire Code; Class I and Class II liquids.
Flammable and Combustible Liquids.
(a) Establishment of limits of districts in which storage of flammable or
combustible liquids in outside aboveground tanks is prohibited.
The limits referred to in Section 5704.2.9.6.1 of said Fire Code, in which the storage of
flammable or combustible liquids in aboveground tanks is prohibited, are established as
to all locations within the City of Saratoga that are residential or congested commercial
areas as determined by the Fire Code Official.
(b) Establishment of limits of districts in which storage of flammable or
combustible liquids in aboveground tanks is prohibited.
The limits referred to in Section 5706.2.4.4 of said Fire Code, in which the storage of
flammable or combustible liquids in aboveground tanks is prohibited, are established as
to all locations of the City of Saratoga that are residential or other locations as
determined by the Fire Code Official.
16- 20.030 - Amendments to Chapter 58 of the Fire Code; Cryogenic Fluids.
(a) Establishment of limits of districts in which the storage of stationary tanks of
flammable cryogenic fluids are to be prohibited.
The limits referred to in Section 5806.2 of said Fire Code, in which the storage of
flammable cryogenic fluids in stationary containers is prohibited, are established as to
all
locations of the City of Saratoga that are residential and congested commercial areas
as determined by the Fire Code Official.
16- 20.040 - Amendments to Chapter 61 of the Fire Code; Liquefied Petroleum Gases.
(a) Establishment of limits in which storage of liquefied petroleum gases is
prohibited.
The limits referred to in Section 6104.2 of said Fire Code, in which storage of liquefied
petroleum gas (LPG) is restricted, are established as to all locations within the City of
Saratoga that are residential or congested commercial areas as determined by the Fire
Code Official.
Exceptions: LPG may be used for industrial operations or when natural gas would not
provide a viable substitute for LPG. Portable containers for temporary heating and /or
cooking uses may be permitted if stored and handled in accordance with this Code.
Facilities in commercial areas for refueling portable or mobile LPG containers may be
approved by the Fire Code Official on a case by case basis.
16- 20.050 - Amendments to Chapter 1, Division II of the Fire Code; Administration.
Section [A] 105.1.4 is added as follows:
[A] 105.1.4 Construction permit fees.
Construction permit fees and plan review fees for fire hydrant systems, fire extinguishing
systems and fire alarm systems shall be paid to the Fire Department in accordance with the
following table based on valuation. The valuation shall be limited to the value of the system for
which the permit is being issued. Plan review fees are 65% of the Permit Fee amount. For the
purposes of determining the total fee amount for each permit, the plan review fee shall be added
to the Permit Fee.
TOTAL VALUATIONS
PERMIT FEE
$1.00 TO $500.00
$23.50
$501.00 TO $2,000.00
$23.50 for the first $500.00 plus $3.05
for each additional $100.00, or fraction thereof,
to and including $2,000.00
$2001.00 TO $25,000.00
$69.25 for the first $2,000.00 plus
$14.00 for each additional $1,000.00 or
fraction thereof, to and including $25,000.00
$25,001.00 TO $50,000.00
$391.25 for the first $25,000.00 plus
$10.10 for each additional$1,000.00, or
fraction thereof, to and including $50,000.00
$50,001.00 TO $100,000.00
$643.75 for the first $50,000.00 plus
$7.00 for each additional$ 1, 000. 00, or fraction
thereof, to and including $100,000.00
$100,001.00 to $500,000.00
$993.75 for the first $100,000.00 plus
$5.60 for each additional$ 1, 000.00, or fraction
Additional re- inspections, in connection with the permits above, are to be paid at $50.00 for
each occurrence at the discretion of the fire code official.
Section [A] 105.1.5 is added as follows:
[A] 105.1.5 Operational permit fees. Operational permit fees shall be paid to the
Fire Department as follows:
FACILITY TYPE
thereof, to and including $500,000.00
$500,001 to $1,000,000.00
$3,233.75 for the first $500,000.00 plus
A. More than 6 persons
$4.75 for each additional$1,000.00, or fraction
B. Over 50 persons
thereof. to and includinq $1,000,000.00
$1,000,001 and up
$5,608.75 for the first
More than 6 clients
$1,000,000.00 plus $3.15 for each
3. Places of Assembly
additional$1,000.00, or fraction thereof
Additional re- inspections, in connection with the permits above, are to be paid at $50.00 for
each occurrence at the discretion of the fire code official.
Section [A] 105.1.5 is added as follows:
[A] 105.1.5 Operational permit fees. Operational permit fees shall be paid to the
Fire Department as follows:
FACILITY TYPE
PERMIT FEE
1. Institutional
A. More than 6 persons
$75.00 - Annually
B. Over 50 persons
$100.00 - Annually
2. Day Care Facilities
More than 6 clients
$35.00 - Annually
3. Places of Assembly
A. 50 -300 persons
$50.00 - Annually
B. Over 300 persons
$85.00 - Annually
4. Temporary Membrane Structures, Tents
and Canopies(Only those requiring permits in
accordance with Section 105.6.43)
$85.00 — Each occurrence
Section [A] 105.6.48 is added as follows:
[A] 105.6.48 Day care facility. An operational permit is required to operate a business as a day
care facility for more than 6 people.
Section [A] 105.6.49 is added as follows:
[A] 105.6.49: Institutional. A permit is required to operate, maintain, or use any institutional
type occupancy. For the purpose of this Section, an institution shall be, but is not limited to:
hospitals, children's homes, homes or institutions for insane or mentally retarded persons,
homes or institutions for the care of aged or senile persons, sanitariums, nursing or
convalescent homes, certified family care homes, residential care homes for the elderly, out of
home placement facilities, halfway houses, and day care nurseries or similar facilities of any
capacity.
Section [A] 106.5 is added as follows:
[A] 106.5 Final Inspection. No final inspection as to all or any portion of a development shall
be deemed completed until the installation of the required fire protection facilities and access
ways have been completed and approved. No final certificate of occupancy may be granted until
the Fire Department issues notice of final clearance of such fire protection facilities and access
ways to the Building Department.
Section [A] 109.4 is amended to read as follows:
[A] 109.4 Violation Penalties. Persons who shall violate a provision of this code or shall fail to
comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in
violation of the approved construction documents or directive of the fire code official, or of a
permit or certificate used under provisions of this code, shall be guilty of a misdemeanor
punishable by a fine of not more than $1,000.00 or by imprisonment not exceeding 365 days or
both such fine and imprisonment. Each day that a violation continues after due notice has been
served shall be deemed a separate offense.
[A] 109.4.1 Abatement of Violation. In addition to the imposition of the penalties herein
described, the fire code official is authorized to institute appropriate action to prevent unlawful
construction or to restrain, correct, or abate a violation; or to prevent illegal occupancy of a
structure or premises; or to stop an illegal act, conduct of business, or occupancy of a structure
on or about any premises.
[A] 109.4.2 Abatement of Hazard. (a) The maintenance of real property in violation of this
code, or of any order of the Fire Department pursuant hereto, is declared to be a public
nuisance and is subject to abatement in accordance with Article 3 -15 of the Saratoga Municipal
Code.
(b) Notwithstanding paragraph (a) of this Section, if real property is maintained in violation of this
code or any order of the Fire Department pursuant hereto and such violation constitutes, in the
opinion of the Fire Chief, a fire hazard of such a nature that immediate action is required to
protect the public health, safety, and welfare, the Fire Department may apply the emergency
nuisance abatement procedure set forth in Article 3 -20 of the Saratoga Municipal Code and take
all necessary and immediate
steps to abate the hazard without prior notice to the owner or occupant of the property. In such
an event, the Fire Chief shall perform the duties of the City Manager as described in Article 3 -20.
(c) The cost of any abatement may be collected through the levy of a special assessment in
accordance with the applicable provisions of Article 3 -15 or Article 3 -20 of the Saratoga
Municipal Code. Such procedure is not intended to be exclusive, and the City or the Fire
Department may simultaneously or successively exercise any other rights and remedies
provided by law.
16- 20.060 - Amendments to Chapter 2 of the Fire Code; Definitions
Chapter 2
DEFINITIONS
SECTION 202 GENERAL DEFINITIONS
Amend the following definition to read:
CONTINUOUS GAS DETECTION SYSTEM. An approved gas detection system where the
analytical inctri imant is maintainPri in rnntinl Inl IC nnpratinn and sampling is performed without
�,,u,y,, u, ,,.,. __ -- - _ ._.. _... -. - -. -
..+..... �.. +�..., A r..,l.. "IL. orl 4n ko r.orfnrmnA nn n rryrliral hacic at intanialc not to PrrPPrl m
ii Re i uptio i. �i ialysis is allowed w uc Nei I v' I VI , u vy.,,,. �.. .
minutes. In occupied areas where air is re- circulated and not exhausted to a treatment system
(e.g. breathing zone), the Chief may require a cyclical basis at intervals not to exceed 5
minutes. The gas detection system shall be able to detect the presence of a gas at or below the
permissible exposure limit in occupiable areas and at or below 1/2 IDLH (or 0.05 LC 50 if no
established IDLH) in unoccupiable areas.
16- 20.070 - Amendments to Chapter 3 of the Fire Code; General Precautions Against Fire.
SECTION 311 VACANT PREMISES
Section 311.1 is amended to read:
311.1 General. Temporarily unoccupied buildings, structures, premises or portions thereof,
including tenant spaces, shall be safeguarded and maintained in accordance with Sections
311.1 through 311.4
SECTION 316 HAZARDS TO FIRE FIGHTERS
Section 316.7 is added as follows:
316.7 Roof Guardrails At Interior Courts.
Roof openings into interior courts that are bounded on all sides by building walls shall be
protected with guardrails. The top of the guardrail shall not be less than 42 inches in
height above the adjacent roof surface that can be walked on. Intermediate rails shall be
designed and spaced such that a 12 -inch diameter sphere cannot pass through.
Exception:
Where the roof opening is greater than 600 square feet in area
16- 20.090 a Amendments to Chapter 5 of the Fire Code; Fire Service Features.
SECTION 503 FIRE APPARATUS ACCESS ROADS
Section 503.1 is amended to read:
503.1 Where required.
Fire apparatus access roads shall be provided and maintained in accordance with
Sections 503.1.1 through 503.1.2 and as per Fire Department Access Road Standards.
Section 503.2.1 is amended to read:
503.2.1 Dimensions.
Fire apparatus access roads shall have an unobstructed width of not less than 20 feet
(6096 mm), exclusive of shoulders, except for approved security gates in accordance
with Section 503.6, and an unobstructed vertical clearance of 13 feet 6 inches (4115
mm).
Exception:
Where there are not more than two Group R, Division 3, or Group U occupancies,
the access road width may be modified by the Fire Code Official.
SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
Section 504.5 is added as follows:
504.5 Access Control Devices.
When access control devices including bars, grates, gates, electric or magnetic locks or
similar devices, which would inhibit rapid fire department emergency access to or within
the building, are installed, such devices shall be approved by the Fire Code Official. All
electrically powered access control devices shall be provided with an approved means
for deactivation or unlocking from a single location or otherwise approved by the Fire
Department. Access control devices shall also comply with Chapter 10 Egress.
SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE
Section 510. 1.1 is added as follows:
510.1.1 Obstruction by new buildings.
When it is determined that a new structure obstructs the line of sight emergency
radio communications to existing buildings or to any other locations, the developer of
the structure shall provide and install the radio retransmission equipment necessary
to restore communications capabilities. The equipment shall be located in an
approved space or area within the new structure.
16- 20.100 - Amendments to Chapter 6 of the Fire Code; Building Services and Systems.
Section 605.12 is added :
605.12 Immersion Heaters.
All electrical immersion heaters used in dip tanks, sinks, vats and similar operations shall
be provided with approved over - temperature controls and low liquid level electrical
disconnects. Manual reset of required protection devices shall be provided.
Section 608.6.4 is added as
follows:
608.6.4 Failure of Ventilation System.
Failure of the ventilation system shall automatically disengage the charging system.
16- 20.110 - Amendments to Chapter 8 of the Fire Code; Interior Finish, Decorative
Materials and Furnishings.
Section 806.1.1 is amended to
readas follows:
Display inside buildings.
The display of Christmas trees and other decorative vegetation shall be in accordance
with the California Code of Regulations, Title 19, Division 1, §3.08 and Sections 806.1
through 806.5.
Exceptions:
Trees located in areas protected by an approved automatic sprinkler system in
accordance Section 903.1.1 or 903.3.1.2 shall not be prohibited in Groups A, E, M, R -1
and R -2.
2. Trees shall be allowed within dwelling units in Group R -2 occupancies.
16- 20.120 - Amendments to Chapter 9 of the Fire Code; Fire Protection Systems.
Section 903.2 is amended to read:
903.2 Where required.
Approved automatic sprinkler systems in new and existing buildings and structures shall
be provided in the locations described in this Section or in Sections 903.2.1 through
903.2.18, whichever is the more restrictive. For the purposes of this section, firewalls and
fire barriers used to separate building areas shall be constructed in accordance with the
California Building Code and shall be without openings or penetrations.
1. In buildings other than residential buildings, which require the installation of fire sprinklers for
all new buildings according to the California Residential Code, an automatic sprinkler system
shall be provided throughout all new buildings and structures.
Exceptions:
a. Buildings and structures that do not exceed 1,000 square feet of building area and
that are not located in the Wildland -Urban Interface Fire Area.
b. Buildings and structures that are located in the Wildland -Urban Interface Fire Area
and do not exceed 500 square feet of building area.
c. Group S -2 or U occupancies that are not located in the Wildland -Urban Interface and
used exclusively for vehicle parking and meeting all of the following conditions:
i. Noncombustible construction;
ii. Maximum building area not to exceed 5,000 square feet;
iii. Structure is open on three (3) or more sides; and
iv. Minimum of 10 feet separation from existing buildings unless area
is separated by fire walls complying with CBC 706.
2. An automatic sprinkler system shall be provided throughout existing buildings and structures
when alterations or additions are made that create conditions described in Sections 903.2.1
through 903.2.18.
3. An automatic sprinkler system shall be provided throughout existing buildings and structures,
when additions are made that increase the building area to more than 3,600 square feet.
Exception:
One or more additions made to a building after January 1, 2011, that do not total more than
1,000 square feet of building area.
4. An automatic sprinkler system shall be provided throughout all new basements regardless of
size and throughout existing basements that are expanded by more than 50 %.
5. Any change in the character of occupancy or in use of any building with a building area equal to
or greater than 3,600 square feet that, in the opinion of the fire code official or building official,
would place the building into a more hazardous division of the same occupancy group or into a
different group of occupancies and constitutes a greater degree of life safety or increased fire
risk, as defined herein, shall require the installation of an approved fire automatic fire sprinkler
system.
a. Life Safety — Increased occupant load, public assembly areas, public meeting areas,
churches, indoor amusement attractions, buildings with complex exiting systems due to
increased occupant loads, large schools /day -care facilities, large residential care facilities with
non - ambulatory
b. Fire Risks — High -piled combustible storage, woodworking operations, hazardous operations
using hazardous materials, increased fuel loads (storage of moderate to highly combustible
materials), increased sources of ignition (welding, automotive repair with the use of flammable
liquids and open flames).
16- 20.130 — Amendments to Chapter 28 of the Fire Code; Lumber Yards and
Woodworking Facilities.
SECTION 2803 GENERAL REQUIREMENTS
Section 2803.8 is added as follows:
2803.8 Fire Protection Water Supply System.
A J t'..., a....a'..... a...- 1.. .J h...Jr.....f hl.�, Fr�r Oho firs kn,� �l
/111 appr oven lit a pr otectio I Water supply aI d 11yu1 al t system suitaAnc 110 a is ii e I IQI�01I u
involved shall be provided for open storage yards and processing areas. Hydrant
systems shall be installed in accordance with National Fire Protection Association
Standard 24.
1620.140 a Amendments to Chapter 33 of the Fire Code; Fire Safety During Construction
and Demolition.
SECTION 3304 PRECAUTIONS AGAINST FIRE
Section 3304.8 is added as follows:
3304.8 Fire Walls.
When firewalls are required, the wall construction shall be completed (with all openings
protected) immediately after the building is sufficiently weather - protected at the location
of the wall(s).
SECTION 3311 MEANS OF EGRESS
Section 3311.1 is amended to read:
[B] 3311.1 Stairways Required.
Each level above the first story in multi -story buildings that require two exit stairways
shall be provided with at least two usable exit stairways after the floor decking is
installed. The stairways shall be continuous and discharge to grade level. Stairways
serving more than two floor levels shall be enclosed (with openings adequately
protected) after exterior walls /windows are in place. Exit stairs in new and in existing,
occupied buildings shall be lighted and maintained clear of debris and construction
materials at all times.
Exception:
For multi -story buildings, one of the required exit stairs may be obstructed on not more
than two contiguous floor levels for the purposes of stairway construction (i.e.,
installation of gypsum board, painting, flooring, etc.).
Section 3311. 1.1 is added as follows:
Section 3311.1.1 Required Means Of Egress.
All buildings under construction shall have at least one unobstructed means of egress.
All means of egress shall be identified in the prefire plan as set forth in Section 3308.2
of the Fire Code.
16- 20.150 - Amendments to Chapter 49 of the Fire Code; Requirements For Wildland-
Urban Interface Fire Areas.
Section 4902 as followsis amended to read:
SECTION 4902 DEFINITIONS
Amend definition of Wildland -Urban Interface Fire Area as follows:
Wildland -Urban Interface Fire Area is a geographical area identified by the state as a "Fire
Hazard Severity Zone" in accordance with the Public Resources Code Sections 4201 through
4204 and Government Code Sections 51175 through 51189 or other areas designated by the
enforcing agency to be at a significant risk from wildfires. The Wildland -Urban Interface Fire
Area shall be defined as all areas within the City of Saratoga as set forth and delineated on the
map entitled "Wildland -Urban Interface Fire Area," which map and all notations, references,
data, and other information shown thereon are hereby adopted and made a part of this chapter.
The map properly attested, shall be on file in the Office of the City Clerk of the City of Saratoga.
SECTION 4906 HAZARDOUS VEGETATION AND FUEL MANAGEMENT
Section 4906.2 is amended to read:
Application.
Buildings and structures located in the following areas shall maintain the required
hazardous vegetation and fuel management:
1. All unincorporated lands designated by the State Board of Forestry and Fire
Protection as State Responsibility Areas (SRA) including:
1.1. Moderate Fire Hazard Severity Zones
1.2. High Fire Hazard Severity Zones
1.3. Very-high Fire Hazard Severity Zones
2. Land designated as a Very-high Fire Hazard Severity Zone or as a Wildland
Urban Interface Fire Area by the City of Saratoga.
SECTION 4907 DEFENSIBLE SPACE
Amend Section 4907.1 to read:
4907.1 General. Defensible space will be maintained around all buildings and
structures in Sate Responsibility Area (SRA) as required in Public Resources Code
4290 and "SRA Fire Safe Regulations" California Code of Regulations, Title 14, Division
1.5, Chapter 7, Subchapter 2, Section 1270.
Buildings and structures within the Very-High Fire Hazard Severity Zones of a Local
Responsibility Area (LRA) shall maintain defensible space as outlined in Government
Code 51175 — 51189 and any local ordinance of the authority having jurisdiction.
Defensible space shall also be provided around water tank structures, water supply
pumps and pump houses.
Persons owning, leasing, controlling, operating or maintaining buildings or structures in
the locally adopted Wildland -Urban Interface Fire Area but that are not within the Very-
High Fire Hazard Severity Zone and persons owning, leasing or controlling land
adjacent to such buildings or structures, shall at all times:
1. Maintain an effective defensible space by removing and clearing away flammable
vegetation and combustible growth from areas within 30 feet (9144 mm) of such
buildings or structures.
Exception: Single specimens of trees, ornamental shrubbery or similar plants
used as ground covers, provided that they do not form a means of rapidly
transmitting fire from the native growth to any structure.
2. Maintain additional effective defensible space by removing brush, flammable
vegetation and combustible growth located 30 feet to 100 feet (9144 mm to 30480
mm) when required by the fire code official due to steepness of terrain or other
conditions that would cause a defensible space of only 30 feet (9144 mm) to be
insufficient.
Exception: Grass and other vegetation located more than 30 feet (9144 mm)
from buildings or structures and less than 18 inches (457 mm) in height above
the ground need not be removed where necessary to stabilize the soil and
prevent erosion.
3. Remove portions of trees, which extend within 10 feet (3048 mm) of the outlet of a
chimney.
4. Maintain trees adjacent to or overhanging a building free of deadwood; and
5. Maintain the roof of a structure free of leaves, needles or other dead vegetative
growth.
6. Remove flammable vegetation a minimum of 30 feet around liquefied petroleum gas
tanks /containers.
7. Firewood and combustible materials shall not be stored in unenclosed spaces
beneath buildings or structures, or on decks or under eaves, canopies or other
projections or overhangs. The storage of firewood and combustible material within
19
the defensible space shall be located a minimum of 30 feet (6096 mm) from
structures and separated from the crown of trees by a minimum horizontal distance
of 15 feet (4572 mm).
Exception: Firewood and combustible materials not for consumption on the
premises shall be stored as approved by the fire code official.
8. Clear areas within 10 feet (3048 mm) of fire apparatus access roads and driveways
of non - fire - resistive vegetation growth.
Exception: Single specimens of trees, ornamental vegetative fuels or cultivated
ground cover, such as greengrass, ivy, succulents or similar plants used as
ground cover, provided they do not form a means of readily transmitting fire.
Section 4907.2 is added as follows:
Corrective Actions.
The executive body is authorized to instruct the Fire Code Official to give notice to the
owner of the property upon which conditions regulated by Section 4907.1 of the Fire
Code exist to correct such conditions. If the owner fails to correct such conditions, the
executive body is authorized to cause the same to be done and make the expense of
such correction a lien upon the property where such conditions exist.
Section 4908 is added as follows:
SECTION 4908 FIRE PROTECTION PLAN
General.
When required by the code official, a fire protection plan shall be prepared.
Content.
The plan shall be based upon a site - specific wildfire risk assessment that includes
considerations of location, topography, aspect, flammable vegetation, climatic conditions,
and fire history. The plan shall address water supply, access, building ignition and fire -
resistance factors, fire protection systems and equipment, defensible space, and
vegetation management.
Cost.
The cost of fire protection plan preparation and review shall be the responsibility of the
applicant.
Plan Retention.
The fire protection plan shall be retained by the Fire Code Official .
Section 4909 is added as follows:
SECTION 4909 WATER SUPPLY
General.
Buildings and structures, or portions thereof, hereafter constructed or relocated into or
within the Wildland -Urban Interface Fire Area shall be provided with fire protection water
supplies in accordance with Chapter 5 and Section 4909.2 of the Fire Code.
Exception:
Agricultural buildings and buildings containing only private garages, carports, or sheds
with a building area of not more than 500 square feet (56 m2).
Standby Power.
Stationary water supply facilities within the wildland -urban interface area that are
dependent on electrical power to meet adequate water supply demands shall provide
standby power systems in accordance with the Electrical Code to ensure that an
uninterrupted water supply is maintained. The standby power source shall be capable of
providing power for a minimum of two hours.
Exceptions:
1. When approved by the Fire Code Official , a standby power supply is not required where
the primary power service to the stationary water supply facility is underground.
2. A standby power supply is not required where the stationary water supply facility
serves no more than one single - family dwelling.
Section 4910 is added as follows:
SECTION 4910 IGNITION SOURCE CONTROL
4910.1 Fireworks.
Fireworks shall not be used or possessed in the Wildland -Urban
I I l f a C-0 F ir a A
te r ea.
16- 20.160 - Amendments to Chapter 50 of the Fire Code; Hazardous Materials - General
Provisions.
Section 5003.9.11 is added to the Fire Code as follows:
5003.9.11 Fire Extinguishing Systems for Workstations Dispensing, Handling, or Using
Hazardous Materials.
Combustible and non - combustible workstations, which dispense, handle, or use
hazardous materials, shall be protected by an approved automatic fire extinguishing
system in accordance with Section 2703.10.
Exception: Internal fire protection is not required for Biological Safety Cabinets that
carry NSF /ANSI certification where quantities of flammable liquids in use or storage
within the cabinet do not exceed 500 ml.
16- 20.170 - Amendments to Chapter 56 of the Fire Code; Explosives and Fireworks.
Chapter 56 of the 2013 California Fire Code is not adopted with the exception of the following
Sections:
Section 5601.1 is adopted and amended to read:
Scope.
For explosives requirements, see California Code of Regulations, Title 19, Division 1,
Chapter 10 and section 5601.2 of this chapter. For fireworks requirements, see
California Code of Regulations, Title 19, Division 1, Chapter 6 and section 5601.3 of this
chapter. For small arms ammunition, see Section 5601.5 of this chapter.
Exceptions:
1. The Armed Forces of the United States, Coast Guard, or National Guard.
2. Explosives in forms prescribed by the official United States Pharmacopoeia.
3. The use of explosive materials by federal, state, and local regulatory, law
enforcement, and fire agencies acting in their official capacities.
4. Items preempted by federal regulations.
Section 5601.2 is added as follows:
Explosives.
The possession, manufacture, storage, sale, handling, and use of explosives are
prohibited.
Section 5601.3 is added as follows:
Fireworks.
The possession, manufacture, storage, sale, handling, and use of fireworks, including
those fireworks classified as Safe and Sane by the California State Fire Marshal, are
prohibited.
Exceptions:
1. Storage, handling and use of fireworks and pyrotechnic special effects outside of
buildings when used for public or proximate audience displays, motion picture, television,
theatrical and group entertainment productions and when in accordance with Title 19 of
the California Code of Regulations.
2. Storage, handling and use of pyrotechnic special effects fireworks inside of buildings
when used for proximate audience displays or special effects in theatrical, television,
motion picture and group entertainment productions when in accordance with Title 19 of
the California Code of Regulations and when in buildings equipped throughout with an
approved fire sprinkler system.
Section 5601.4 is added as follows:
Rocketry.
The storage, handling, and use of model rockets shall be in accordance with Title 19 of
the California Code of Regulations and as approved by the fire code official.
Add Sections 5601.5 through 5601.5.3.2.3 to read:
5601.5 Small Arms Ammunition - General. Indoor storage and display of black powder,
smokeless propellants and small arms ammunition shall comply with Sections 5601.5.1
through 5601.5.4.2.3.
5601.5.1 Packages. Smokeless propellants shall be stored in approved shipping
containers conforming to DOTn 49 CFR, Part 173.
5601.5.1.1 Repackaging. The bulk repackaging of smokeless propellants, black
powder and small arms primers shall not be performed in retail establishments.
5601.5.1.2 Damaged packages. Damaged containers shall not be repackaged.
Exception: Approved repackaging of damaged containers of smokeless propellant into
containers of the same type and size as the original container.
5601.5.2 Storage in Group R occupancies. The storage of small arms ammunition in
Group R occupancies shall comply with Sections 5601.5.2.1 through 5601.5.2.3.
5601.5.2.1 Smokeless propellants. Smokeless propellants intended for personal use
in quantities not exceet?Ing 20 pounds (9 kg) are permitted tU be staled iii Group R -3
occupancies where kept in original containers. Smokeless powder in quantities
Pxceedina 20 pounds (9 ka) but not exceeding 50 pounds (23 ka) are Permitted to be
stored in Group R -3 occupancies where kept in a wooden box or cabinet having walls of
at least 1 inch (25 mm) nominal thickness.
5601.5.2.2 Black powder. Black powder intended for personal use in quantities not
exceeding 20 pounds (9 kg) are permitted to be stored in Group R -3 occupancies where
kept in original containers and stored in a wooden box or cabinet having walls of at least
1 inch (25 mm) nominal thickness
5601.5.2.3 Small arms primers. No more than 10,000 small arms primers shall be
stored in Group R -3 occupancies.
5601.5.3 Display and storage in Group M occupancies. The display and storage of
small arms ammunition in Group M occupancies shall comply with Sections 5601.5.3.1
through 5601.5.3.2.3.
5601.5.3.1 Display. The display of small arms ammunition in Group M occupancies
shall comply with Sections 5601.5.3.1.1 through 5601.5.3.1.3.
5601.5.3.1.1 Smokeless propellant. No more than 20 pounds (9 kg) of smokeless
propellants, each in containers of 1 pound (0.454 kg) or less capacity, shall be
displayed in Group M occupancies.
5601.5.3.1.2 Black powder. No more than 1 pound (0.454 kg) of black powder shall be
displayed in Group M occupancies.
5601.5.3.1.3 Small arms primers. No more than 10,000 small arms primers shall be
displayed in Group M occupancies.
5601.5.3.2 Storage. The storage of small arms ammunition in Group M occupancies
shall comply with Sections 5601.5.3.2.1 through 5601.5.3.2.3.
5601.5.3.2.1 Storage of Smokeless propellant. Commercial stocks of smokeless
propellants not on display shall not exceed 100 pounds (45 kg). Quantities exceeding
20 pounds (9 kg), but not exceeding 100 pounds (45 kg) shall be stored in portable
wooden boxes having wails of at least 1 inch (25 mm) nominal thickness.
5601.5.3.2.2 Black powder. Commercial stocks of black powder not on display shall
not exceed 50 pounds (23 kg) and shall be stored in a type 4 indoor magazine. When
black powder and smokeless propellants are stored together in the same magazine, the
total quantity shall not exceed that permitted for black powder.
5601.5.3.2.3 Small arms primers. Commercial stocks of small arms primers not on
display shall not exceed 750,000. Storage shall be arranged such that not more than
100,000 small arms primers are stored in any one pile and piles are at least 15 feet
(4572 mm) apart.
16- 20.180 - Amendments to Chapter 57 of the Fire Code; Flammable and Combustible
Liquids.
SECTION 5704 STORAGE
Section 5704.2.7.5.8 is amended to read:
Overfill Prevention.
An approved means or method in accordance with Section 5704.2.9.7.6 shall be
provided to prevent the overfill of all Class I, 11, and IIIA liquid storage tanks. Storage
tanks in refineries, bulk plants, or terminals regulated by Sections 5706.4 or 5706.7
shall have overfill protection in accordance with API 2350. An approved means or
method in accordance with Section 5704.2.9.7.6 shall be provided to prevent the
overfilling of Class 1116 liquid storage tanks connected to fuel burning equipment inside
buildings.
Section 5704.2.7.5.9 is added as follows:
Automatic Filling of Tanks.
Systems that automatically fill flammable or combustible liquid tanks shall be equipped
with overfill protection, approved by the Fire Code Official, which sends an alarm signal
to
a constantly attended location and immediately stops the filling of the tank. The alarm
signal and automatic shutoff shall be tested on an annual basis and records of such
testing shall be maintained on -site for a period of five (5) years.
16- 25.010. Adoption of California Plumbing Code.
The 2013 California Plumbing Code, Title 24; Part 5; including Appendix Chapters A, B,
C, D, H, and I only, hereinafter referred to as the "Plumbing Code," is referred to and
such code is adopted and made a part hereof, the same as if fully set forth in this Article,
and shall be the Plumbing Code of the City. However, in accordance with California
Government Code Section 50222.4, no penalty clauses are adopted by reference. In
accordance with California Government Code Section 50022.6, at least one true copy of
the Plumbing Code has been on file with the City Clerk since fifteen days prior to
enactment of the ordinance codified in this Article. While the ordinance codified in this
Article is in force, a true copy of the Plumbing Code shall be kept for public inspection in
the office of the Building Official. A reasonable supply of the Plumbing Code shall be
available in the office of the City Clerk for public purchase.
16- 30.010 Adoption of California Mechanical Code.
The 2013 California Mechanical Code, Title 24, Part 4, including all appendices,
hereinafter referred to as the "Mechanical Code," is referred to and such code is adopted
and made a part hereof, the same as if fully set forth in this Article, and shall be the
Mechanical Code of the City. However, in accordance with California Government Code
Section 50222.4, no penalty clauses are adopted by reference. In accordance with
California Government Code Section 50022.6, at least one true copy of the Mechanical
Code has been on file with the City Clerk since fifteen days prior to enactment of the
ordinance codified in this Article. While the ordinance codified in this Article is in force, a
true copy of the Mechanical Code shall be kept for public inspection in the office of the
Building Official. A reasonable supply of the Mechanical Code shall be available in the
office of the City Clerk for public purchase.
16- 35.010 Adoption of California Electrical Code.
The 2013 California Electrical Code, Title 24, Part 3, hereinafter referred to as the
"Electrical Code," is referred to and such code is adopted and made a part hereof, the
same as if fully set forth in this Article, and shall be the Electrical Code of the City.
However, in accordance with California Government Code Section 50222.4, no penalty
clauses are adopted by reference. In accordance with California Government Code
Section 50022.6, at least one true copy of the Electrical Code has been on file with the
Citv Clerk since fifteen days prior to enactment of the ordinance codified in this Article.
While the ordinance codified in this Article is in force, a true copy of the Electrical
Code shall be kept for public inspection in the office of the Building Official. A
reasonable supply of the Electrical Code shall be available in the office of the City
Clerk for public purchase.
16- 49.010 Adoption of California Green Building Standards Code.
The 2013 California Green Building Standards Code , Title 24, Part 11, hereinafter
referred to as the "Green Building Standards Code," is referred to and such code is
adopted and made a part hereof, the same as if fully set forth in this Article, and shall
be the Green Building Standards Code of the City. However, in accordance with
California Government Code Section 50222.4, no penalty clauses are adopted by
reference. In accordance with California Government Code Section 50022.6, at least
one true copy of the Green Building Standards Code has been on file with the City
Clerk since fifteen days prior to enactment of the ordinance codified in this Article.
While the ordinance codified in this Article is in force, a true copy of the Green Building
Standards Code shall be kept for public inspection in the office of the Building Official.
A reasonable supply of the Green Building Standards Code shall be available in the
office of the City Clerk for public purchase.
Add Section:
16- 51.010 Adoption of California Energy Code.
The 2013 California Energy Code ,Title 24, Part 6, hereinafter referred to as
the Energy Code," is referred to and such code is adopted and made a part hereof,
the same as if fully set forth in this Article, and shall be the Energy Code of the City.
However, in accordance with California Government Code Section 50222.4, no
penalty clauses are adopted by reference. In accordance with California Government
Code Section 50022.6, at least one true copy of the Energy Code has been on file
with the City Clerk since fifteen days prior to enactment of the ordinance codified in
this Article. While the ordinance codified in this Article is in force, a true copy of the
Energy Code shall be kept for public inspection in the office of the Building Official. A
reasonable supply of the Energy Code shall be available in the office of the City Clerk
for public purchase.