Loading...
HomeMy WebLinkAbout03-22-17 Planning Commission Agenda Packet SARATOGA PLANNING COMMISSION REGULAR MEETING MARCH 22, 2017 7:00 PM PLANNING COMMISSION REGULAR MEETING Civic Theater | 13777 Fruitvale Avenue, Saratoga CA 95070 PLEDGE OF ALLEGIANCE ROLL CALL APPROVAL OF MINUTES Action Minutes from the Regular Planning Commission Meeting of March 8, 2017. ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS Any member of the public will be allowed to address the Planning Commission for up to three (3) minutes on matters not on this agenda. This law generally prohibits the Planning Commission from discussing or taking action on such items. However, the Planning Commission may instruct staff accordingly regarding Oral Communications. REPORT ON APPEAL RIGHTS If you wish to appeal any decision on this Agenda, you may file an Appeal Application with the City Clerk within fifteen (15) calendar days of the date of the decision. 1. NEW BUSINESS 2. PUBLIC HEARING Applicants and/or their representatives have a total of ten (10) minutes maximum for opening statements. All interested persons may appear and be heard during this meeting regarding the items on this agenda. If items on this agenda are challenged in court, members of the public may be limited to raising only issues raised at the Public Hearing or in written correspondence delivered to the Planning Commission at, or prior to the close of the Public Hearing. Members of the public may comment on any item for up to three (3) minutes. Applicants and/or their representatives have a total of five (5) minutes maximum for closing statements. 2.1 Application PSP16-0001; 14410 Big Basin Way (517-09-089); Lands of Canciamilla (c/o Cal Bay Property Management). The applicant is requesting approval of a sign program for the shopping center. Staff contact: Nicole Johnson (408) 868-1209 or njohnson@saratoga.ca.us Recommended Action: Adopt Resolution No. 17-010 approving the project subject to recommended conditions of approval included in Attachment 1. Saratoga Planning Commission Agenda – Page 1 of 2 2.2 Application PDR16-0024/ARB16-0061; 20972 Saratoga Hills Road (503-29-034); Lands of Tsai The applicant is requesting Design Review approval for a Categorically Permitted Project to remodel an existing two story single-family home located at 20972 Saratoga Hills Road. The project would include an expansion of the main level and the construction of a new garage. Two protected trees are proposed for removal including a California bay and a Valley oak. Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us Recommended Action: Adopt Resolution No. 17-009 approving the project subject to conditions of approval included in Attachment 1. DIRECTOR ITEMS COMMISSION ITEMS ADJOURNMENT CERTIFICATE OF POSTING OF THE AGENDA I, Erwin Ordoñez, Community Development Director for the City of Saratoga, declare that the foregoing agenda for the meeting of the Planning Commission was posted and available for public review on March 17, 2017 at the City of Saratoga, 13777 Fruitvale Avenue, Saratoga, CA 95070 and on the City’s website at www.saratoga.ca.us. Signed this 17th day of March 2017 at Saratoga, California. Erwin Ordoñez, Community Development Director In Compliance with the Americans with Disabilities Act, if you need assistance to participate in this meeting, please contact the City Clerk at 408/868-1269. Notification 24 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility to this meeting. [28 CFR 35.102-35.104 ADA title II] You can also sign up to receive email notifications when Commission agendas and minutes have been added to the City at website http://www.saratoga.ca.us/contact/email_subscriptions.asp. NOTE: To view previous Planning Commission meetings anytime, go the City Video Archives at www.saratoga.ca.us Saratoga Planning Commission Agenda – Page 2 of 2 REPORT TO THE PLANNING COMMISSION 14410 Big Basin Way Meeting Date: March 22, 2017 Application #: PSP16-0001 Address/APN: 14410 Big Basin Way (APN 517-07-018) Property Owner: Canciamilla (c/o Cal Bay Property Management) Staff Planner: Nicole Johnson, Planner II 14410 Big Basin Wy 4 Summary PROJECT DESCRIPTION The applicant is requesting Planning Commission approval for a new Sign Program for the shopping center located at 14410 Big Basin Way (the northeast corner of Big Basin Way and Saratoga-Los Gatos Road). The lot size is approximately 5,280 square feet and the property is located in the Commercial-Historic 1 zoning district. Pursuant to SMC 15-30.160 (c), the Planning Commission shall review and approve or deny all Sign Program applications. STAFF RECOMMENDATION Staff recommends that the Planning Commission approve the application for a Sign Program with required findings and conditions by adopting the Resolution in Attachment 1. PROJECT DISCUSSION Saratoga Municipal Code (SMC) Section 15-30.160 (b) requires that a Sign Program be approved prior to the installation of any new permanent advertising signs when there are five (5) or more uses on a commercial property. The existing sign approvals for the center were approved without a sign program because there were only four tenant spaces. The four existing tenants include: Chase Bank, Starbucks Coffee, Rejuve, and Club Pilates. Prior to the departure of Minicakes by Tasha one of the existing spaces was subdivided with demising walls to create an additional tenant space. That additional space has recently been rented, which increased the number of uses to the minimum number specified by the City Code (i.e. five spaces) for requiring a Sign Program. The purpose of a Sign Program is to achieve a consistent theme and visual harmony among all permanent signs proposed for a commercial property. A Sign Program is used to create standard sign design guidelines and criteria for properties with multiple buildings or tenants. Once a Sign Program is approved by the Commission, future tenants are eligible to receive approval for their individual signs at an administrative staff level rather than through the Planning Commission process. The applicant’s proposed Sign Program includes three (3) sign types: wall signs, projecting signs, and miscellaneous signs (window and A-Frame). The location requirement of the wall signs for each suite has been provided in the Sign Program (Attachment 2). A description of the permitted signs in the proposed Sign Program can be found below. Sign Type A-Wall sign • Not to exceed 0.5 SF per 1’ of building frontage to a maximum of 40 square feet (per tenant) • All signs will be 3/4” dimensional letters constructed of a durable material (wood, metal, or acrylic) Report to the Planning Commission 14410 Big Basin Way PSP16-0001 March 22, 2017 5 Sign Type B – Projecting Signs • Suite B will be allowed to have one projecting sign which will be located on the side of suite F above the driveway entrance • The sign shall not exceed 10 square feet in size and must have a minimum clearance of 10’ from grade to the bottom of the sign • The sign cannot project above the roofline of the building Sign Type C – Miscellaneous Signs In addition to wall signs, each tenant will be allowed miscellaneous signs: • Window Signs  Window signs cannot exceed 25% of the window area • A-frame Signs  Tenants are allowed one A-frame sign which cannot exceed 6 square feet in area or 4’ in height and must be located within 10’ of the primary business entrance. The signs must be constructed of all-weather wood, metal, and/or blackboard, and can only be displayed during business hours. The signs cannot be affixed to any tree or structure. Lighting The wall lights shall be lit by the existing gooseneck light fixtures. The fixtures are down shielded and do not create additional glare onto neighboring properties/businesses. Materials The City’s sign ordinance requires that all permanent signs shall be constructed and maintained with high quality all-weather wood, metal, or durable synthetic material. The proposed Sign Program complies with this prerequisite by requiring the signs to be constructed of either wood, metal, or acrylic. Sign Area Sign area is the area of the smallest rectangle drawn to include all sign copy (e.g., letters, characters, symbols, graphics, and logos). The proposed Sign Program is consistent with SMC Section 15- 30.120 and limiting the wall sign area to forty (40) square feet. Consistency with Saratoga Village Commercial Design Guidelines Staff has reviewed the proposed Sign Program for consistently with the Village Sign District Sign Program and found it consistent with type and size of signs allowed in the adjacent area. Findings: The findings required for issuance of a Sign Program approval pursuant to City Code Section 15- 30.160 (e) are set forth below and the applicant has met the burden of proof to support making all of those required findings: 1. The total area of all permanent signs governed by the Sign Program is not greater than the total area of all permanent signs otherwise allowed on the lot by this Article. The Sign Program has been conditioned to comply with Article 15-30 and the Report to the Planning Commission 14410 Big Basin Way PSP16-0001 March 22, 2017 6 regulations in the zoning district. In accordance with City Code Section 15-30.120, the Sign Program regulates that the total wall sign (type A) area per tenant will not exceed forty (40) square feet in area. Also, in accordance with City Code Section 15-30.40 the letters will be no more than 18" in height. The other signs (type B and C) have also been designed to comply with Article 15-30. This finding can be made in the affirmative. 2. All signs in the Sign Program are consistent with the applicable specific plan and/or design guidelines for the subject district. This finding can be made in the affirmative. The signs will be compatible with the visual characteristics of the surrounding area. 3. The quantity, size, proportion, height, and spacing of signs minimize the perception of clutter. This finding can be made in the affirmative. The Sign Program requires that wall signs will be ¾” dimensional individual letters constructed of a durable material (wood, metal, or acrylic. Signs will be located along the fascia of the building and will not extend above the ridge line of a building. Window signs shall not exceed 25% of the window area, which is consistent with the City’s current sign regulations. 4. The signs governed by the Sign Program are compatible with: a) other nearby signs; b) the building and/or site upon which it is located; and c) adjacent structures and the general vicinity. Compatibility shall be determined and limited to the relationships of the elements of form, proportion, scale, color, materials, surface treatment, overall sign size and height, and the size and style of lettering. This finding can be made in the affirmative. The Sign Program regulates the location, size, design, and illumination of the signs such that they will not adversely affect the quality or character of the surrounding area. Neighbor Notification All property owners within 500 feet were notified. To date, Staff has not received any comments on this Sign Program request. Environmental Determination The proposed Master Sign Program is Categorically Exempt from the California Environmental Quality Act (CEQA) pursuant to Title 14 of the California Code of Regulations, Chapter 3, Article 19, Section 15311 (“State CEQA Guidelines”). A Class 11 exemption includes the construction or placement of on premise commercial facility signs. Staff Recommendation Staff recommends that the Planning Commission approve the application with the conditions of approval and findings in the resolution included in Attachment 1. ATTACHMENTS 1. Resolution #17-010 2. Proposed Sign Program Report to the Planning Commission 14410 Big Basin Way PSP16-0001 March 22, 2017 7 RESOLUTION NO: 17-010 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING A SIGN PROGRAM APPLICATION NO. PSP16-0001 14410 BIG BASIN WAY WHEREAS, on November 14, 2016 an application was submitted by Tony & Maria Canciamilla requesting approval for a sign program for the shopping center located at 14410 Big Basin Way. The site is located within the CH-1 Zoning District (APN 517-09-089). WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA), and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on March 22, 2017, the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The proposed Sign Program is Categorically Exempt from the California Environmental Quality Act (CEQA) pursuant to Title 14 of the California Code of Regulations, Chapter 3, Article 19, Section 15311 (“State CEQA Guidelines”). This exemption allows for the construction or placement of on premise commercial facility signs. Section 3: The findings required for issuance of a Sign Permit Approval pursuant to City Code Section 15-30.160 (e) are set forth below and the Applicant has met the burden of proof to support making all of those required findings: 1. The total area of all permanent signs governed by the sign program is not greater than the total area of all permanent signs otherwise allowed on the lot by this Article. The Sign Program has been conditioned to comply with Article 15-30 and the regulations in the zoning district. In accordance with City Code Section 15-30.120, the Sign Program regulates that the total wall sign (type A) area per tenant will not exceed forty (40) square feet in area. Also, in accordance with City Code Section 15-30.40 the letters will be no more than 18" in height. The other signs (type B and C) have also been designed to comply with Article 15-30. This finding can be made in the affirmative. 2. All signs in the sign program are consistent with the applicable specific plan and/or design guidelines for the subject district. This finding can be made in the affirmative. The signs will be compatible with the visual characteristics of the surrounding area. Attachment 1 8 3. The quantity, size, proportion, height, and spacing of signs minimize the perception of clutter. This finding can be made in the affirmative. The Sign Program requires that wall signs will be ¾” dimensional individual letters constructed of a durable material (wood, metal, or acrylic. Signs will be located along the fascia of the building and will not extend above the ridge line of a building. Window signs shall not exceed 25% of the window area, which is consistent with the City’s current sign regulations. 4. The signs governed by the sign program are compatible with: a) other nearby signs; b) the building and/or site upon which it is located; and c) adjacent structures and the general vicinity. Compatibility shall be determined and limited to the relationships of the elements of form, proportion, scale, color, materials, surface treatment, overall sign size and height, and the size and style of lettering. This finding can be made in the affirmative. The Sign Program regulates the location, size, design, and illumination of the signs such that they will not adversely affect the quality or character of the surrounding area. Section 5: The City of Saratoga Planning Commission hereby approves PSP16-0001 located at 14410 Big Basin Way, subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 22nd day of March 2017 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ DeDe Smullen Chair, Planning Commission Lands of Canciamilla 14410 Big Basin Way, Application #PSP16-0001 Resolution #17-010 Page | 2 9 Exhibit 1 CONDITIONS OF APPROVAL APPLICATION NO. PSP16-0001 14410 BIG BASIN WAY (APN 517-09-089) CONDITIONS OF APPROVAL A. GENERAL 1. Conditions may be modified only by the Planning Commission unless modification is expressly otherwise allowed by the City Code including but not limited to section 16-05.035, as applicable. 2. The Community Development Director shall mail to the Owner/Applicant a notice in writing, on or after the time this Resolution of Approval is duly executed by the City, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the Community Development Director certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The facilities shall at all times operate in compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdictional authority over the facility pertaining to, but not limited to, health, sanitation, safety, and water quality issues. The Project shall maintain compliance with all applicable requirements of the State, County, City and other governmental entities having jurisdiction. 4. Agreement to Indemnify, Hold Harmless and Defend City as to Action Challenging Approval of Application and as to Damage from Performance of Work Authorized by Design Review Approval. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. Lands of Canciamilla 14410 Big Basin Way, Application #PSP16-0001 Resolution #17-010 Page | 3 10 In addition, prior to any Zoning Clearance from the Community Development Director, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold harmless and Defend, which shall be subject to prior approval as to form and content by the Community Development Director. B. COMMUNITY DEVELOPMENT 5. Compliance with Plans. The Sign Program shall be operated, located and constructed to include those features, and only those features, as shown on the Approved Plans denominated Exhibit "A" date stamped February 28, 2017 incorporated by this reference. All proposed changes to the Approved Plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to the requisite prior City approval. 6. Municipal Code. The Sign Program shall comply with the requirements in Article 15-30 in the Saratoga Municipal Code. 7. Building Department. Applicant shall comply with all building standards including any permits necessary to comply with the building code. 8. Illuminated Signage. No existing, proposed for future sign addressed in this Sign Program shall be illuminated. Any intensification, modification, or request for illuminated signage to the Sign Program shall require approval of an amended permit by the Planning Commission. 9. Business License Requirement. Any and all businesses of shopping center that request signage per the Sign Program shall apply for and obtain approval of a Business License from the City of Saratoga prior to issuance of sign permit. 10. Owner Approval. All signage requires prior approval from the existing owner of the property prior to submittal to the City. Lands of Canciamilla 14410 Big Basin Way, Application #PSP16-0001 Resolution #17-010 Page | 4 11 MASTER SIGN PROGRAM –14410 BIG BASIN WAY 1/29/17 1 MASTER SIGN PROGRAM 14410 Big Basin Way Attachment 2 12 MASTER SIGN PROGRAM –14410 BIG BASIN WAY 1/29/17 2 OVERVIEW The purpose of this sign program is to create a uniform style of signage throughout the property, while still allowing individual tenants to properly identify their business. The sign program will insure that all tenant signage is of a consistently high quality which will assist in maintaining the visual appearance of the property. This Master Sign Program will be administered, interpreted, and approved by the landlord and City of Saratoga. Any signage approvals issued by the landlord through the use of this sign program will be subject to approval by the City of Saratoga. The sign sizes listed in this program are the minimum/maximum allowed and the City of Saratoga will not process or permit signs that fall outside of these parameters. The sign program lists the type and style of signs mandated for these properties. Any sign types not expressly listed in this program will not be allowed. GENERAL REQUIREMENTS 1.Each tenant will submit to the landlord and City of Saratoga, before installation, detailed drawings of any proposed signage. The tenant will not apply for any permits with the City of Saratoga until the landlord has provided their written approval to the tenant for the proposed signage. 2.All permits and installation of signs will be the sole responsibility of the tenant and/or their contractor. The tenant will be responsible for any expenses related to the removal of signage. 3.All bolts, anchors, fasteners, clips, etc., on the signage shall be concealed from view. 4.The tenant and/or their contractor will be responsible for repairing any damage caused by the installation or removal of signage, at the tenant’s cost. 5.Any signs installed without the approval of the landlord and City of Saratoga will be removed within 15 days of written notice from the landlord, at the tenant’s cost. 6.Tenants shall be responsible for the maintenance of their signs. 7.Signs which are not listed in this sign program but are required by law shall be allowed. 13 MASTER SIGN PROGRAM –14410 BIG BASIN WAY 1/29/17 3 PROHIBITED SIGNS 1.Sign types not listed in this sign program. 2.Flashing, animated, or moving signs. 3.Signs with raceways. 4.Off-premises signs. 5.Signs that obstruct ingress and egress or ventilation. 6.Roof mounted signs. 7.Cabinet or box signs. 8.Pole signs. 9.Signs that create traffic hazards. 10.Vehicle display signs. 11.Signs on public property. CONTACT INFORMATION Questions regarding the requirements for signage permits should be directed to the City of Saratoga Planning Division (408-868-1222) and questions regarding building permits should be directed to the City of Saratoga Building Division (408-848-1240).All other questions should be directed to the landlord. SIGN OVERVIEW Sign Type A –Wall signs Sign Type B –Projecting signs Sign Type C –Miscellaneous signs 14 MASTER SIGN PROGRAM –14410 BIG BASIN WAY 1/29/17 4 SIGN TYPE A –Wall Signs DESCRIPTION/LOCATION Each tenant will be allowed to have wall signage based on the tenant’s location as follows: Suite A –One wall sign facing Big Basin Way on the upper fascia of the building and one wall sign facing the parking lot/Saratoga-Los Gatos Road also located on the upper fascia of the building. Suite B –One wall sign over their main entrance facing the rear parking area which is located on the lower fascia area below the 2nd floor window and one wall sign on the side of Suite F above the driveway entrance to the rear parking lot which is located on the upper fascia area. Suite C –One wall sign over the main entrance facing the parking lot located on the upper fascia of the building and one wall sign on the side elevation facing Saratoga-Los Gatos Road which is also located on the upper fascia of the building. Suite D –One wall sign on the side elevation facing the parking lot on the upper fascia of the building and one wall sign facing Saratoga-Los Gatos Road on the lower fascia of the building. Suite E –One wall sign located on the lower fascia of the building facing Saratoga-Los Gatos Road. Suite F –One wall sign located on the lower fascia of the building facing Saratoga-Los Gatos Road. Wall sign area cannot exceed 0.5 SF per 1’ of building frontage to a maximum of 40 SF per tenant.All signs will be 3/4” dimensional letters constructed of a durable material (wood,metal, or acrylic). See exhibits A and B for specific locations on each tenant space. ILLUMINATION All signs will be illuminated using existing external gooseneck lighting provided by the landlord. Any proposed changes to existing lighting fixtures or locations must be approved by the landlord and City of Saratoga. FONT Tenants may select their own font for signage pending approval from landlord and City of Saratoga. COLORS/MATERIALS Sign colors may be chosen by tenant pending approval from landlord and City of Saratoga. All signs will be constructed of a either wood, metal or acrylic. SIGN DIMENSIONS All signs will be 3/4” flat cut out letters and will have a maximum height of 18” for a single line of copy, and in no case shall a sign exceed 36” in height if more than one line of copy (see Exhibit C).Signs that consist of just a logo with no separate lettering may be up to 36” in height. 15 MASTER SIGN PROGRAM –14410 BIG BASIN WAY 1/29/17 5 SIGN TYPE B –Projecting Signs Only the tenant located in Suite B will be allowed to have one projecting sign which will be located on the side of suite F above the driveway entrance (see exhibit B for specific location). The sign cannot exceed 10 SF in size and must have a minimum clearance of 10’ from grade to the bottom of the sign, and the sign cannot project above the roofline of the building. LOCATION Sign will be located on the side of suite F above the driveway (see Exhibit A). SIGN DIMENSIONS The sign cannot exceed 10 SF in area. ILLUMINATION The sign will be non-illuminated. COLORS/MATERIALS Sign colors may be chosen by tenant pending approval from landlord and City of Saratoga. All signs will be constructed of a durable material such as wood, metal, acrylic, etc., the sign support must be metal and approved by landlord and City of Saratoga. 16 MASTER SIGN PROGRAM –14410 BIG BASIN WAY 1/29/17 6 SIGN TYPE C –Miscellaneous Signs In addition to wall signs each tenant will be allowed miscellaneous signs as permitted by the City of Saratoga sign ordinance: WINDOW SIGNS Window signs cannot exceed 25% of the window area. A-FRAME SIGNS Tenants are allowed one A-Frame sign which cannot exceed 6 SF in area or 4’ in height and must be located within 10’ of the primary business entrance. The signs must be constructed of all -weather wood, metal, and/or blackboard, and can only be displayed during business hours. The signs cannot be affixed to any tree or structure. 17 18 19 20 21 REPORT TO THE PLANNING COMMISSION Meeting Date: March 22, 2017 Application: PDR16-0024 / ARB16-0061 Location / APN: 20972 Saratoga Hills Road / 503-29-034 Owner/Applicant: Kevin Tsai / Noel Cross Staff Planner: Christopher Riordan 20972 Saratoga Hills Road SITE 22 20972 Saratoga Hills Road Summary PROJECT DESCRIPTION: The applicant is requesting Design Review approval for a Categorically Permitted Project to remodel an existing 4,467 square foot two-story split level single-family home located at 20972 Saratoga Hills Road. Proposed improvements include a 1,125 square foot addition to the main level, conversion of existing lower floor area to a two car garage, retaining walls, paving, and new deer fencing. There would be no increase in building height. Two protected trees in fair condition are proposed for removal including a California bay and a Valley Oak. STAFF RECOMMENDATION: Adopt Resolution No. 17-009 approving the project subject to conditions of approval. Approval by the Planning Commission is required pursuant to City Code Sections 15-45.060(a) (9) (Planning Commission design review; public hearing) and 16-65.060 Ground Movement Regulations (Categorically permitted projects in Pmw, Pd, and Pdf areas). PROJECT DATA: Net Site Area: 76,656 square feet (1.76 acres) Average Site Slope: 26.3% General Plan Designation: RVLD (Residential Very Low Density) Zoning: R-1-40,000 Proposed Allowed/Required Conformance Proposed Site Coverage Residential Footprint Driveway Walkways Patio / Landings Permeable Paving Total Proposed Site Coverage 4,736 sq. ft. 3,766 sq. ft. 368 sq. ft. 273 sq. ft. 914 sq. ft. 10,057 sq. ft. (13%) 26,830 SF (35%) Conforms Floor Area Lower Floor Upper Floor Garage (attached) Total Floor Area 1,362 sq. ft. 3,360 sq. ft. 605 sq. ft. 5,327 sq. ft. 5,922 sq. ft. Conforms Height (Residence) Lowest Elevation Point: Highest Elevation Point: Average Elevation Point: Proposed Topmost Point: Total Proposed Height 592.67 603.50 598.09 617.87 (19.78 ft.) 26 Feet Conforms Page 2 of 8 23 20972 Saratoga Hills Road Setbacks Front: Exterior Side Interior Side Rear ** Lots with 3 sides have no rear lot line First Second First Second Conforms 65’-1” 27’-0” 88’-0” ** 65’-1” 47’-0” 56’-3” ** 30’ 25’ 20’ ** NA 30’ 25’ ** Grading Cut 106 CY Fill 113 CY Total 219 CY No Grading Limit in R-1-40,000 Conforms PROJECT DESCRIPTION AND SITE CHARACTERISTICS Site Description: The 76,656 (net) square foot project site is located at 20972 Saratoga Hills Road within the R-1-40,000 zoning district. The project site is a long, irregularly shaped triangular parcel that is bounded to the west by a private residence and two segments of Saratoga Hills Road (a private street) to the north and south. The roadway paving of Saratoga Hill Road is approximately12-18 wide and constructed within a wider 50-wide right-of-way that is located inside the property lines of the subject property. A drainage swale is located alongside the north segment of the private street that traverses the property. Private streets are not maintained by the City because they are typically owned by the residents using the street and maintained by a Home Owners Association or some other private entity. The subject property is improved with an existing 4,467 square foot two story single-family home that is located in the middle of the parcel. The existing house is characterized by vertical wood siding with a cross gable roof. An existing asphalt driveway along the western property line provides primary site access. No enclosed vehicle parking is located on site. A swimming pool and associated equipment are located to the southeast of the structure and at a lower elevation. Surrounding homes are predominantly two-story homes with a variety of architectural styles and dates of construction. The area is characterized by relatively steep slopes and dense vegetation which screen the views of neighboring properties. The adjacent residence to the west is located at a close distance and is visible due to sparse vegetation in this area. No other residential properties are visible. Two protected trees in fair condition are proposed for removal including a California bay and a Valley Oak. Project Description and Architectural Style: The applicants desire to remodel the existing home but it is located in a geologically sensitive area Pd (Potentially Deep Landslide) Geologic Hazard Zone. City Code Section 16-65.040 Ground Movement Regulations (Pmw, Pd, Pdf and Ms area restrictions) requires the preparation of a geologic and geotechnical investigation report and that a site development plan be approved by the City's Geotechnical Consultant prior to any permit approvals or issuance. The proposed remodel will modify the home’s existing architectural style. The existing house is a split level contemporary design with vertical wood siding and a cross gable roof. The front entrance is located at the upper level of the western elevation. The lower level is located at the back of the home and screened from view from the street by existing vegetation. Page 3 of 8 24 20972 Saratoga Hills Road The project would include a 960 square foot addition to the upper level and remodeling of 1,952 square feet of floor area to allow for upgraded living space in the home with a two car garage. The split level design takes advantage of the lower slope at the back of the house by locating the projects two story element and overall massing behind the front elevation. This complies with the criteria established for Categorically Permitted Projects in the City Code which limits proposed additions in geologically sensitive areas to a maximum of 25-percent of the existing square footage of the home (1,116 s.f.) or 500 square feet, whichever is greater, and also limits proposed remodeling of the remaining structure to 50-percent of the existing square footage of the home (2,223 s.f.). The design intent of the project designer was to modify the character of the home as allowed by the City’s regulations to achieve an updated contemporary architectural appearance. The existing wood siding will be removed and replaced with a combination of horizontal wood siding, stucco, and stone veneer. All the existing windows will be replaced with vinyl clad wood windows. The existing swimming pool and associated equipment would be removed and not replaced. The existing asphalt driveway would be removed and replaced with a new concrete driveway. A colors and materials board is on file with the Community Development Department and will be present at the site visit and public hearing. The following table lists the proposed exterior materials. Materials and Colors: Detail Colors and Materials Exterior Slate Grey Horizontal Wood Siding Tan Stucco Sydney Peak Azul Blend Stone Veneer Brown Fascia, Eaves, Trim Windows Dark Bronze Aluminum Clad Wood Windows Garage Door Sectional Wood Door – Match house trim color Roof Weathered Wood Color Composition Shingles Trees: Two protected trees in fair condition have been approved by the City Arborist for removal. These two trees include a 15” California bay and an 18” Valley oak. Both trees are located near the driveway approach to the new garage. Details of the arborist findings are included in the Arborist report which is included as Attachment 2. All the remaining protected trees in the vicinity of the project will be protected during construction. Page 4 of 8 25 20972 Saratoga Hills Road Geotechnical Review: In 2015 the City Council reviewed and approved an amendment to the City’s Ground Movement regulations (Article 16-65) to provide a minimum amount of flexibility for homeowners within the most constrained geologic zones to add on or remodel their homes without compromising the stringent safety requirements adopted by the City. If after the preparation of a geologic and geotechnical investigation report, project approval cannot be obtained from the City’s Geotechnical Consultant, City Code Section 16-65.060 Ground Movement Regulations (Categorically permitted projects in Pmw, Pd, and Pdf areas) also allows for as an alternative, a very limited addition to be consider by the Planning Commission as a “Categorically Permitted Project”. Such a project is limited to the following criteria: • A maximum remodel of fifty percent of the square footage of the existing building • An addition of five hundred square feet or twenty-five percent of the square footage of the existing building or structure, whichever is greater • The remodeled structure shall not exceed six thousand square feet. • May only be approved when it is clearly demonstrated to the City's Geotechnical Consultant that such categorically permitted project will improve the overall safety of existing buildings and will not unduly jeopardize human safety, property on the site, or adjoining public or private property • Use standards of practice structural/geotechnical engineering methods taking into account the underlying geology. • Limitation and control of the final project and construction process, including grading and the use of excavation equipment, drilling equipment and trucks, so as to minimize impacts on the natural characteristics of the site. • Control of drainage to minimize on-site and offsite adverse impacts. • Demonstration that the improvements do not interfere with existing, or proposed, septic tanks and/or drainfields and that the septic system complies with applicable public health standards. • Stabilization of actively moving ground when deemed necessary and feasible. • Improvement of the overall safety of a building or structure and site over the safety of the building or structure and site that existed prior to making improvements. Improvements shall address problems related to the geologic stability of the site, but may address other factors, for example, improvements in fire safety. • Avoidance of imposing a risk to adjoining properties. • Adequate demonstration that the building or structure is a legally existing building or structure • The owner of the property has executed and filed with the City Clerk a written statement and indemnity agreement All applications submitted for a Categorically Permitted Project are required to submit a geotechnical report for review by the City’s Geotechnical Consultant to specify all necessary geotechnical remediation’s for the project. Categorically Permitted Projects are required to meet all modern building and seismic code regulations. Additionally, a Categorically Permitted Page 5 of 8 26 20972 Saratoga Hills Road Project will be required to demonstrate to the City’s Geotechnical Consultant, that the design of the project will include an “Engineered Design” which will improve the overall safety of the existing building. An Engineered Design requires appropriate soil, foundation, and structural measures to provide an improved foundation and an overall safer development than the existing home on the project site. The applicant submitted a geotechnical report prepared by Murray Engineers, Inc. with an addendum dated November 16, 2016, which was reviewed by the City Geologist. The City Geologist concurred with the project geologist that the project as designed should not be subject to structural integrity/collapse and provided Geotechnical Clearance for the project. A copy of the City Geologist review report is included as Attachment 4. Residential Calgreen Measures: The project will exceed the minimum CalGreen standards. The Residential Calgreen Measures Checklist is included at Attachment 5. Neighbor Notification and Correspondence: Copies of the neighbor notification forms are included as Attachment 4. None of the notification forms included project related comments. A Public Notice was also sent to property owners within 500 feet of the site. FINDINGS Design Review Findings: The findings required for issuance of a Design Review approval pursuant to City Code Article 15- 45 are set forth below and the Applicant has met the burden of proof to support making all of those required findings: (a) Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. The project meets this finding in that the project is proposing both lower and upper story floor additions to an existing house that is already constructed as a split level that follows the natural contours of the site. Minimal grading is proposed to construct the addition to the existing lower level and the overall grading quantity for the entire site is limited to a combined total of 219 cubic yards. No grading material will be exported off site. (b) All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. The project meets this finding in that the project site is characterized by lush vegetation that screens adjacent properties. A total of 48 protected trees are located in the vicinity of the project which was reviewed by the City Arborist. With the exception of one California bay and one Valley oak in fair condition that would be removed to construct the approach to the garage, all remaining trees will be preserved and protected during construction. No heritage trees are located onsite. Page 6 of 8 27 20972 Saratoga Hills Road (c) The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the 3.9 acre size of the parcel, the distance from the subject project to adjacent structures, and existing and proposed vegetation and trees would screen views from adjacent properties. Views from second story windows would be towards vegetated area where not homes are visible. The project would not impact any identified community viewsheds. (d) The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. The project meets this finding in that the project would include a modest addition to the main level and remodeling of approximately 50- percent of the existing structure. The split level design takes advantage of the lower slope at the back of the house by locating the projects two story element and overall massing behind the front elevation. The impression of building height as viewed from the street is reduced as the building has wide horizontal proportions; there are consistent gable roof forms with sufficient architectural articulation and projections to reduce the impression of bulk. The neutral color pallet would aid in blending the home with the proposed landscaping. Existing trees and mature landscaping help screen the building as viewed from offsite. (e) The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood streetscape. The projects meet this finding in that the existing landscape located within the front setback is characterized by native plants and trees. The applicant will maintain the existing landscaping and no new landscaping within the front setback is proposed. The neighborhood streetscape is dominated by landscaping that is native to the area and the projects existing landscaping would be consistent. (f) Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. The project meets this finding in that due to the location of the structure, its height, and the building setbacks, the development will not unreasonably impair the ability or opportunity of adjoining properties to utilize solar energy. (g) The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. The project meets this finding in that the project has managed massing through appropriate building design with the majority of the massing located toward the rear of the building footprint and not visible street. In addition, the use of excessive colors and materials has been minimized, appurtenances are designed in proportion to the overall building form and neighborhood and the exterior materials would complement the streetscape. (h) On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Sections 15-45.055. The project meets this finding in that the site is defined as a hillside lot however, its location on Saratoga Hills Road is not near any ridgelines, the project grading is limited to 219 cubic yards for the construction of the lower level addition and no significant hillside features will be impacted, no community viewsheds would be impacted, and the project Page 7 of 8 28 20972 Saratoga Hills Road is in compliance with City Code Section 15-45.055 (Single-Family Residential Design Review Guidelines). Environmental Determination: The project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New Construction or Conversion of Small Structures”, of the Public Resources Code (CEQA). This exemption allows for the construction of up to three single-family residences and no exception to that exemption applies. STAFF RECOMMENDATION: Adopt Resolution No. 17-009 approving the project, subject to conditions of approval. ATTACHMENTS: 1. Resolution of Approval for Design Review 2. Applicant’s Project Description 3. Arborist Report 4. Geotechnical Clearance Report 5. Neighbor Notification Forms 6. CalGreen Checklist 7. Development Plans (Exhibit "A") Page 8 of 8 29 RESOLUTION NO: 17-009 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR16-0024 AND ARBORIST REPORT ARB16-0061 LOCATED AT 20972 SARATOGA HILLS ROAD WHEREAS, on October 24, 2016, an application was submitted by Noel Cross (Applicant) on behalf of Kevin Tsai (Property Owner) requesting Design Review approval for a Categorically Permitted Project to remodel an existing 4,467 square foot two-story split level single- family home located at 20972 Saratoga Hills Road. Proposed improvements would include an 860 square foot addition to the main level and remodeling of 1,952 square feet of existing of the existing structure. There would be no increase in building height. Two protected trees in fair condition are proposed for removal including a California bay and a Valley Oak. The site is located within the R- 1-40,000 Zoning District (APN 503-29-034). WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA), and recommends that the Planning Commission determine this project exempt. WHEREAS, on March 22, 2017, the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of one single-family residence in a residential area. Section 3: The project is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The project is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings in that the project follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints; preserves protected trees; is designed to avoid unreasonable impacts to the privacy of adjoining Attachment 1 30 Resolution No. 17-009 properties and to community viewsheds; the mass and height of the structure and its architectural elements are in scale with the structure itself and with the neighborhood; landscaping minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape; does not unreasonably impair the ability of adjoining properties to utilize solar energy; and is consistent with the Residential Design Review Handbook. Section 5: The City of Saratoga Planning Commission hereby approves PDR16-0024 and ARB12-0061 located at 20972 Saratoga Hills Road, subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 22nd day of March 2017 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ DeDe Smullen Chair, Planning Commission 31 Resolution No. 17-009 Exhibit 1 CONDITIONS OF APPROVAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. Construction must be commenced within 36 months from the date of this approval (March 22, 2020), or the resolution will expire. 5. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. 32 Resolution No. 17-009 COMMUNITY DEVELOPMENT 6. Site Drainage. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 7. Compliance with Plans. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Plans denominated Exhibit "A" dated stamped September 19, 2016. All proposed changes to the Approved Plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 8. Exterior Lighting. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full-cut off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 9. Construction Hours & Noise. In order to comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 10. Construction Management Plan. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 11. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. The proposed deer fence shall not exceed a height of 6’ and shall be painted black. 33 Resolution No. 17-009 12. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall take into account the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency and plant interactions to ensure successful establishment. d. Any proposed or required under grounding of utilities shall take into account potential damage to roots of protected trees ARBORIST 13. All requirements in the City Arborist Reports dated March 6, 2017 are hereby adopted as conditions of approval and shall be implemented as part of the Approved Plans. This includes, but is not limited to; all tree related conditions set forth above and the following standard conditions of approval: a. Tree Bond. Prior to issuance of any Building Permit, the Project Applicant or Owner shall obtain and submit to the Community Development Department a Tree Bond in favor of the City in the amount of $10,200 to guarantee the replacement of any removed trees or rehabilitation of any damaged trees in a manner satisfactory to the City Arborist. b. Release of Tree Bond. Prior to the City’s inspection for final approval of the completed Project, the City Arborist shall inspect the site to verify compliance with all conditions of approval related to trees. The Tree Bond required above shall be released after the planting of required replacement trees, a site inspection by the City Arborist finding compliance with all tree-related conditions contained in this Resolution, and payment of any outstanding City Arborist fees. FIRE DEPARTMENT 14. The owner/applicant shall comply with all Fire Department requirements. PUBLIC WORKS 15. All requirements in the City’s Geotechnical Clearance dated December 6, 2016 are hereby adopted as conditions of approval and shall be implemented as part of the Approved Plans. 34 Resolution No. 17-009 16. The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations, retaining walls and driveway) to ensure that their recommendations have been properly incorporated. The results of the plan review shall be summarized by the geotechnical consultant in a letter and submitted to the City Engineer for review and approval prior to issuance of building permits. 17. The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections shall include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the City Engineer for review prior to final (granting of occupancy) project approval. 18. The owner (applicant) shall pay any outstanding fees associated with the City Geotechnical Consultant’s review of the project prior to Zone Clearance. 19. The owner (applicant) shall enter into an agreement holding the City of Saratoga harmless from any claims or liabilities caused by or arising out of soil or slope instability, slides, slope failure or other soil related and/or erosion related conditions. 20. Prior to building permit issuance, the applicant shall videotape the surface of Saratoga Hills Road that provides access to the site. One copy of the tape shall be retained by the Community Development Department and one copy shall be provided to the applicable Home Owners Association. Any damage to the road caused by project related construction shall be repaired by the applicant prior to building permit final inspection approvals. BUILDING DEPARTMENT 21. Building Division Submittal. Four (4) sets of complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, be of a size acceptable to the City, and at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. d. The site plan shall contain a note with the following language: “Prior to foundation inspection by the City, the Licensed Land Surveyor of record shall provide a written certification that all building setbacks comply with the Approved Plans,” which note shall represent a condition which must be satisfied to remain in compliance with this Design Review Approval. 35 Attachment 2 36 37 38 39 40 41 Community Development Department City of Saratoga 13777 Fruitvale Avenue Saratoga, California 95070 ARBORIST REPORT Application No. ARB16-0024 Prepared by Kate Bear, City Arborist Site: 20972 Saratoga Hills Road Phone: (408) 868-1276 Owner: Kevin Tsai Email: kbear@saratoga.ca.us APN: 503-29-034 Email: uclatsai@gmail.com Report History: Final report Date: March 3, 2017 PROJECT SCOPE: The applicant has submitted plans to add on to and remodel the existing house. The existing swimming pool will be demolished as part of the project. Two trees (12 and 15) protected by Cit y Code are requested for removal to construct the project. STATUS: Approved by City Arborist, with attached conditions. PROJECT DATA IN BRIEF: Tree bond – Required - $59,185 For trees 1 – 9, 11, 16 – 19, 20, 23 – 26, 33 – 37, 41 and 42 Tree fencing – Required – See Conditions of Approval and attached map. Tree removals – Trees 12 and 15 are approved for removal once building permits have been issued. Replacement trees – Required = $10,200 ATTACHMENTS: 1 – Findings 2 – Tree Removal Criteria 3 – Tree Information 4 – Conditions of Approval 5 – Map Showing Tree Protection 1 42 20972 Saratoga Hills Road Attachment 1 FINDINGS: Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. Two trees (bay tree 12 and oak tree 15) are requested for removal to construct the project. Both trees meet the City’s criteria allowing them to be removed and replaced as part of the project, once building division permits have been obtained. Attachment 2 contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No. Species Criteria met 12 California bay 4, 5, 7, 9 15 Valley oak 1, 4, 6, 7, 9 New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15- 50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1) The submitted arborist report dated February 7, 2017; and 2) This report dated March 3, 2017. 2 43 20972 Saratoga Hills Road Attachment 2 TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2) The necessit y to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the propert y. (3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularl y on steep slopes. (4) The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beaut y, property values, erosion control, and the general welfare of residents in the area. (5) The age and number of healthy trees the property is able to support according to good forestry practices. (6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7) Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8) Any other information relevant to the public health, safet y, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9) The necessit y to remove the tree for economic or other enjoyment of the propert y when there is no other feasible alternative to the removal. (10) The necessit y to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. 3 44 20972 Saratoga Hills Road Attachment 3 TREE INFORMATION: Arborist Report reviewed: Preparer: Michael Young, Urban Tree Management, Inc. Date of Report: February 7, 2017 An arborist report was submitted for this project that inventoried 46 trees protected by Saratoga City Code. Information on the condition of each tree, potential impacts from construction, suitability for preservation, appraised values and tree protection recommendations was provided. A table summarizing information about each tree is below. Two trees (12 and 15) protected by Saratoga City Code are requested for removal to construct this project. Tree 10 is not protected by City Code and may be removed at any time without a permit. Table 2: List of trees from February 7, 2017 arborist report. 4 45 20972 Saratoga Hills Road Attachment 3 Table 2 continued: List of trees from February 7, 2017 arborist report. 5 46 20972 Saratoga Hills Road Attachment 3 Table 3: Appraised values of trees from February 7, 2017 arborist report. 6 47 20972 Saratoga Hills Road Attachment 3 Table 3 continued: Appraised values of trees from February 7, 2017 arborist report. 7 48 20972 Saratoga Hills Road Attachment 4 CONDITIONS OF APPROVAL 1. It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2. All recommendations in the arborist report dated Februar y 7, 201 prepared by Michael Young shall become conditions of approval. 3. The arborist report dated Februar y 7, 2017 shall be copied on to a plan sheet, titled “Tree Preservation” and included in the final job copy set of plans. 4. This report dated March 3, 2017 shall be copied onto a plan sheet and included in the final set of plans. 5. The designated Project Arborist shall be Michael Young of Urban Tree Management, Inc., unless otherwise approved by the City Arborist. 6. Tree Protection Security Deposit a. Is required per City Ordinance 15-50.080. b. Shall be $59,185 for tree(s) 1 – 9, 11, 16 – 19, 20, 23 – 26, 33 – 37, 41 and 42. c. Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d. Ma y b e in the form of cash, check, credit card payment or a bond. e. Shall remain in place for the duration of construction of the project. f. May be released once the project has been completed, inspected and approved by the City Arborist. 7. Tree Protection Fencing: a. Shall be installed as shown on the attached map. b. Shall be shown on the Site Plan. c. Shall be established prior to the arrival of construction equipment or materials on site. d. Shall be comprised of six-foot high chain link fencing mounted on eight-foot tall, 2-inch diameter galvanized posts, driven 24 inches into the ground and spaced no more than 10 feet apart. e. Shall be posted with signs saying “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, KATE BEAR (408) 868-1276”. f. Call City Arborist, Kate Bear at (408) 868-1276 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. g. Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 8. If contractor feels that work must be done inside the fenced area, call City Arborist to arrange a field meeting before performing work. 8 49 20972 Saratoga Hills Road Attachment 4 9. The Project Arborist shall visit the site every two weeks during grading, excavation and trenching activities and every six weeks thereafter. Following visits to the site, the Project Arborist shall provide the City with a report including photos documenting the progress of the project and noting any tree issues. 10. The Project Arborist shall monitor: a. Installation of the drainage dissipaters by trees 16, 17, 31 and 32. b. Installation of the driveway and fire truck turnaround by trees 1, 2, 33 and 34. c. Construction of the driveway and retaining walls by trees 4 – 9, 11 and 16. d. Removal of the pool equipment by trees 41 and 42. e. Installation of the patio by tree 19. f. Installation of utilities near trees. 11. No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 12. Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. 13. All construction activities shall be conducted outside tree protection fencing. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 14. Trenching to install utilities is not permitted inside tree protection fencing. 15. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. Roots measuring less than two inches in diameter may be cut using a sharp pruning tool. 16. Any permitted pruning or root pruning of trees on site shall be performed under the supervision of the Project Arborist and according to ISA standards. 17. Trees 12 and 15 meet the criteria for removal and may be removed and replaced once Building Division permits have been obtained. 18. Trees permitted for removal shall be replaced on or off site according to good forestry practices, and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. The value of the removed trees shall be calculated in accordance with the ISA Guide for Plant Appraisal. 19. New trees equal to $10,200 shall be planted as part of the project before final inspection and occupancy of the new home. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 9 50 20972 Saratoga Hills Road Attachment 4 20. New trees may be of an y species and planted an ywhere on the propert y. 21. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 22. Water loving plants and lawns are not permitted under oak tree canopies. 23. Should any tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessar y number of new trees, some of the value for trees may be paid into the City’s Tree Fund. 24. Following completion of the work around trees, and before a final inspection of the project, the applicant shall provide a letter to the City from the Project Arborist. That letter shall document the work performed around trees, include photos of the work in progress, and provide information on the condition of the trees. 25. At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call City Arborist for a final inspection. 10 51 $WWDFKPHQW >P v d W }}v &v]vP ı ^}P ,]oo Z } 11 52 $WWDFKPHQW >P v d W }}v &v]vP ı ^}P ,]oo Z } 12 53 CITY of SARATOGA 13777 FRUITVALE AVENUE • SARATOGA, CALIFORNIA 95070 (408) 868-1274 MEMORANDUM TO: Iveta Harvancik, Senior Engineer DATE: December 6, 2016 FROM: Cotton Shires and Associates, Inc., City Geotechnical Consultant SUBJECT: Supplemental Geotechnical Peer Review (S5094) RE: Tsai, Residential Renovations and Additions GEO16-0026 (previously GEO14-0014) 20972 Saratoga Hills Road At your request, we have completed a supplemental geotechnical peer review of the subject application using: •Supplemental Information – Tsai Residence Improvements (letter) prepared by Murray Engineers, Inc., dated November 16, 2016; •Geotechnical Investigation (report) prepared by Murray Engineers, Inc., dated July 29, 2016; •Engineering Geologic Investigation (report) prepared by Murray Engineers, Inc., dated September 26, 2014; •Architectural Plans (9 sheets) prepared by Noel Cross Architects, dated October 19, 2016; and •Grading and Drainage Plans (7 sheets) prepared by Jakaby Engineering, dated August 26, 2016. In addition, we have reviewed pertinent technical documents from our office files and inspected a previous site geologic exploration shaft. DISCUSSION We understand that the applicant proposes to remodel and construct new additions onto the existing residence. Driveway modifications are also proposed. We have previously noted that the subject property is underlain by a mapped large Old Landslide and is mapped within the “Pd” ground movement potential category. Building and grading permits for properties within a Pd area are restricted unless a geologic and soils investigation concludes that proposed improvements, as designed, will be safe for the intended use from ground movement. Alternatively, limited Categorically Permitted Projects may be allowed if the proposed construction will improve the overall safety of the site dwelling. We understand that the proposed construction is intended to comply with the size restrictions of a Categorically Permitted Project. Attachment 4 54 Iveta Harvancik December 16, 2016 Page 2 S5094 CONCLUSIONS AND RECOMMENDED ACTION The proposed project will include significant structural upgrades to supporting walls and house foundations. The Project Geotechnical Consultant has indicated that the project will improve the performance of the house foundation system and make the residence structurally safer and less susceptible to landslide impacts. We understand that City Planning will evaluate compliance of the proposed project design with size restrictions. The applicant should be willing to accept the potential need for repairs of the structure in the event of future deep landslide movement. Given applicant acceptance of the above, we recommend approval of Project Geotechnical Clearance with the following conditions: 1. Geotechnical Plan Review - The applicant's geotechnical consultant shall review and approve all geotechnical aspects of the final building construction and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations, and retaining walls) to ensure that their recommendations have been properly incorporated. The results of the plan review shall be summarized by the geotechnical consultant in a letter and submitted to the City Engineer for review prior to issuance of building permits. 2. Geotechnical Construction Inspections - The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections shall include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The Consultant shall observe the excavation/drilling of foundation piers and verify satisfactory embedment. Final site drainage improvements shall be inspected for conformance with geotechnical recommendations. The results of these inspections and the as-built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the City Engineer for review prior to final (as- built) project approval. LIMITATIONS This supplemental geotechnical peer review has been performed to provide technical advice to assist the City in its discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. Our opinions and conclusions are made in accordance with generally accepted principles and practices of the geotechnical profession. This warranty is in lieu of all other warranties, either expressed or implied. TS:DTS:kc 55 Attachment 5 56 57 58 59 60 Attachment 6 61 62 63 64 65 66 67 68 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! m aterial or c on struc tion process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l at t enti on to lo cati n g# p ro c u ri n g# and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A0.0 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects A B B R E V I A T I O N S & and e east L angle ea each @ at elev elevation O diameter elec electrical # pounds or nu mber encl enclosure (e) existing eq equal, equivalent (n) new equip equipment cL centerlin e exp expansion ext exterior ac asphaltic c oncrete acst acous tical fa fire alarm adj adjustable fd floor drain aggr aggregate fnd foundation alum alumin um fec fire extinguisher cabinet aprox approximately fin finish arch architectural flr floor fluor fluorescent bd board foc face of concrete bitum bitumin ous fof face of finish bldg building fos face of stud blkg blocking ft foot or feet bm beam ftg footing bot bottom furr furring fut future cabt cabinet cb catch b asin ga gauge cem cement galv galvanized cer ceramic gb grab bar ci cast ir on g.i. galvanized iron clg ceiling gl/gls glass clos closet gr grade clr clear gyp gypsum co cased openi ng/clean out col column hb hose bibb conc concrete hc hollow core cont contin uous hdwe hardware contr contr actor hgt height cntr counter cy cubic yard hm hollow metal hngr hanger horiz horizontal dbl double hr hour dept department hwd hardwood det detail df douglas fir id inside diameter dia diameter inst install, installation dim dimension insul insulation disp disposal or dispenser int interior dn down dwr drawer jan janitor dr door jnt joint ds downs pou t jst joist dwg drawing d.f douglas fir kit kitchen ABBREVIATIONS lam laminate s south lav lavatory sc solid core lt light sched schedule sec section max maximum serv service mc medicine cabinet sh shelf mech mechanical sht sheet memb membrane shwr shower mtl metal sim similar manuf manufacturer specs specifications min minimum sq square misc miscellaneous ss stainless steel or sanitary sewer mntd mounted sta station std standard n north stl steel nic not in contract negl neglible stor storage sd storm drain no number struct structural nom nominal sb straw bale nts not to scale sym symmetrical obsc obscure t tread oc on center tel telephone od outside diameter ter terrazzo off office t&g tongue and groove opp opposite thk thick toc top of curb pl plate tow top of wall prtn partition tv television plywd plywood typ typical pr pair pt point or paint unf unfinished ptdf pressure treated douglas fir (use ACQ) uno unless noted otherwise ugnd underground pise pneumatically impacted stabilized earth util utility qt quarry tile vert vertical vest vestibule r riser rad radius w west rd roof drain w/with ref reference wc water closet refr refrigerator wd wood reinf reinforced w/o without reqd required wp waterproof rm room wsct wainscot ro rough opening wt weight rwd redwood re rammed earth yd yard CONSULTANT DIRECTORY Architect Noel F. Cross, AIA License C-018234 noel@nfcarchitect.com Noel Cross+Architects 148 E. Virginia Street #2 San Jose, California 95112 Phone (408) 216-0222 Cell (408) 591-5795 Interior Designer Vivian Soliemani vivian@vsoldesign.com Vivian Soliemani Design, Inc. 634 N Santa Cruz Ave., Suite 103 Los Gatos, California 95030 Phone (408) 560-9604 Landscape Designer Johnna Brooks johnna.divinenature@gmail. com Divine Nature Landscape Design 115 Alpine Avenue Los Gatos, CA 95030 Cell (408) 222-0418 Surveyor Roger Dodge L.L.S. #3295 lions4c6@msn.com Dodge & Associates, Surveying 20652 Chaparral Circle Penn Valley, California 95946 Phone (530) 432-5212 Cell (530) 575-0076 Civil Engineer J. Thomas Jakaby, S.E. CA License #S-4168 jtj@jakabyse.com Jakaby Engineering 1885 S. Winchester Blvd., Suite A Campbell, California 95008 Phone (408) 374-6149 Fax (408) 374-5911 Soils Engineer Andrew D. Murray P .E . #C -44562 andrew@murrayengineers.com Murray Engineers, Inc. 935 Fremont Avenue Los Altos, California 94024 Phone (650) 559-9980 cell (650) 533-6191 Engineering Geologist Mark F. Baumann C .E .G . #1787 mark@murrayengineers.com Murray Engineers, Inc. 935 Fremont Avenue Los Altos, California 94024 Phone (650) 559-9980 cell (650) 533-6191 Arborist Michael P. Young Certified Arborist WC ISA #623 info@UrbanTreeManagement. com Urban Tree Management, Inc. PO Box 971 Los Gatos, California 95031 Phone 650-321-0202 Fax 408-399-8063 SHEET INDEX ARCHITECTURAL DRAWINGS A -0.0 Title Sheet, Vicinity Map, General Notes, Consultant Directory, Sheet Index, Floor Area & Coverage Tabulations, Parcel Map, Abbreviations A -1.0 (N) Site Plan @ 1"=40', Tree Protection Detail A -1.1 (N) Partial Site Plan @ 1/10"=1'-0” & Notes A -1.1a Partial Site Plan @ 1/10"=1'-0”, Arborist Tree Survey/Report A -1.2 (N) Site Sections A, B & C @ 1/8” = 1’-0” A -1.3 (N) Site Sections D, E & F @ 1/8” = 1’-0” A -3.0 New Upper Floor Plan @ 1/4” = 1’-0” & Legend A -3.1 New Lower Floor Plan @ 1/4” = 1’-0” & Legend A -5 .0 New West & North Exterior Elevations @ 1/4"=1'-0" & Notes A -5 .1 New East & South Exterior Elevations @ 1/4"=1'-0" & Notes A -6 .0 New Roof Plan @ 1/4"=1'-0" A -10.0 Main Floor Demo Plan @ 1/4"=1'-0" & Legend A -10.1 Lower Floor Demo Plan @ 1/4"=1'-0" & Legend A -10.2 Existing West & North Exterior Elevations @ 1/4"=1'-0" A -10.3 Existing East & South Exterior Elevations @ 1/4"=1'-0" LANDSCAPE DRAWINGS by Nature Landscape Design DN-01 Planting Plan DN-02 Planting Plan Understory DN-03 Planting Notes DN-04 Plant Board DN-05 Lighting Plan/Boulder Layout DN-06 Deer Fence and Entry Gate CIVIL DRAWINGS by Jakaby Engineering C -1.0 Civil Notes C -1.1 Grading & Drainage Plan @ 1” = 10’-0” C -1.2 Erosion Control Plan @ 1” = 10’-0” C -2 .1 Driveway Profile Sections C -3 .1 Straw Roll Details, Infiltration Trench Detail, Energy Dissipator Detail, Site Retaining Wall Detail SURVEY DRAWINGS by Roger Dodge & Associates T -1.0 Topographic Survey @ 1” = 30’-0” T -1.1 Partial Topographic Survey @ 1” = 20’-0” FIRE SAFETY REQUIREMENTS 1.Automatic Fire Sprinkler System @ Entire Residence submit three (3) sets of shop drawings/hydraulic calcs to: Santa Clara County Fire Department 14700 Winchester Blvd. Los Gatos, CA 95032-1818 (408) 378-4010 phone (408) 378 -9342 fax Fire protection sub- contractor is responsible for verification of existing water flow, or providing new water flow meeting fire dept. requirements as follows: - flow location - static pressure, psi - residual pressure, psi - flow, gpm - date - time - test conducted by or information supplied by __________________. per NFPA Standard #13D , 2016 CBC & 2016 CFC, and all local ordinances, the contractor shall install an approved automatic fire sprinkler system throughout all portions of the new residence per the Santa Clara County Fire Department typical. a .) fast response fire sprinkler heads shall be installed throughout the garage and all contiguous areas within the structure. b .) The Santa Clara County Fire Dept. must issue a permit prior to the installation of the fire sprinkler system. c .) the sprinkler contractor must have a Town business license and worker’s comp certificate. d .) fire sprinkler water: as required by San Jose Water Co., provide new 1½” dia. water meter. provide new 2” dia. underground copper water main feed (w/ blue plastic protective jacket) where shown to house tee and check valve at fire sprinkler riser, typical. Fire sprinkler sub-contractor must be C -16 Licensed and shall submit system design, hydraulic calculations, & shop drawings for approval by The Santa Clara County Fire Dept. and in compliance with the National Fire Protection Association (NFPA) Standard #13-D , 2016 CFC. Drawings are to include locations of all new heads, risers, valves, pipe sizes, layouts, required pressures, alarms, details, etc. System shall be designed & installed per The Santa Clara County Fire Dept. Standard Details & Specs, typical, u.n .o . It shall be the responsibility of the contractor to verify that the existing water meter is at least 1 1/2” dia. if not, then upgrade the existing water meter as required for the proper operation of the new domestic water system, & the new fire sprinkler system. See note #2 below for additional information. 2.Potable Water Supplies Final approval of system(s) under consideration will not be granted by The Santa Clara County Fire Dept. until compliance with the requirements of the water purveyor of record are documented in writing by that purveyor as having been met by the applicant(s). per sec. 903.3.5, 2016 CFC & sec. 13114.7, California Health & Safety Code, all potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subs to contact the water purveyor supplying the project site, and to comply with the requirements of that purveyor. Backflow prevention requirements shall be incorporated into the design of any water based fire containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor. 3.Construction Site Fire Safety per 2016 CFC Chapter 33 All construction sites must comply w/ applicable provisions of the 2013 CFC Chapter 33, and the Santa Clara County Fire Dept. Standard Detail and Specification SI-7. provide appropriate notations on subsequent plan submittals, as appropriate to the project. 4.Early Warning Fire Alarm System (EWAS) a .) EWAS shall be installed in compliance with 2016 NFPA Standard 72A and Saratoga City Ordinance 16-60. b .) the alarm contractor shall provide (3) copies of the working drawings to the Fire District for review and approval. c .) the Fire District must issue a permit prior to the installation of the EWAS. d .) the alarm contractor must have a City of Saratoga business license and worker’s compensation certificate. HEIGHT INFORMATION TABLE HEIGHT Foot Elevation Lowest Elevation Point at building edge from natural grade. 592.67’ Highest Elevation Point at buildings edge from natural grade. 603.50’ Average Elevation Point (based on highest and lowest points above). 614.33’ Top Most Elevation Point (measured from average point (above) to top most point of the roof. 617.87’ Top Most Elevation Point (measured from average point (above) to top most point on the chimney). 620.00’ SETBACKS TABLE SETBACKS Required Proposed Front 30’-0” 65’-1” Exterior Side First Floor 25’-0” 27’-0” Exterior Side Second Floor 30’-0” 47’-0” Interior Side First Floor 20’-0” 88’-0” Interior Side Second Floor 25’-0” 56’-3” Rear First Floor No rear setback Rear Second Floor No rear setback = Gross Site Area =76,656 s.f Covergae Allowable x 0.35 =26,830 s.f Footprint of Home/Garage (including roof O.H.)=4,736 s.f. Driveway =3,766 s.f. Walkways =368 s.f. Rear Patio/Stoops =273 s.f. =9,143 s.f. Actual S.F.50% Credit Total S.F. Parking =1,026 -513 =513 s.f. Front Deck =174 -87 =87 s.f. Rear Patio =255 -128 =128 s.f. Rear Stairs =88 -44 =44 s.f. Bridges =284 -142 =142 s.f. =1,827 -914 =914 s.f. =10,057 s.f. =16,773 s.f. • IMPERVIOUS COVERAGE TABLE Max. Allowable Impervious Coverage Impervious Surfaces 35% of Gross Lot Area Allowable Impervious Coverage Pervious Surfaces (b) Subtotal Pervious (a) Subtotal Impervious Site Coverage Total (a) + (b) Wood Deck Areas counted at 50% per Saratoga Code Section 15-13.080 Site Coverage Impervious Coverage Remaining 14 FEBRUARY 2017 PLANNING RESUBMITTAL1 GENERAL NOTES 1.Verification contractor and all subcontractors shall establish all building lines, floor levels, etc., and shall verify all grades, conditions, dimensions, and data at the site prior to start of work; errors resulting from failure to verify all figures shall be the responsibility of the contractor and each subcontractor. 2.Dimensions do not scale these drawings. written dimensions take precedence over scaled drawings. the contractor shall notify the architect immediately of any conflicts or discrepancies, however minor. 3.Discrepancies minor discrepancies btwn. the drawings & actual site conditions are expected. any and all conditions requiring even minor clarification shall be brought to the attention of the architect immediately, preferably a minimum of 48 hours prior to the beginning any demolition or construction sequence. 4.Codes all work shall be in conformance with the following codes, as well as all applicable state codes & local city or county ordinances: 2016 California Building Code (C.B .C .) (based on 2012 International Building Code) 2016 California Residential Code (C.R .C .) (based on 2012 International Residential Code) 2016 California Electrical Code (C.E .C .) (based on 2011 National Electrical Code) 2016 California Plumbing Code (C.P .C .) (based on 2012 Uniform Plumbing Code) 2016 California Mechanical Code (C.M .C .) (based on 2012 Uniform Mechanical Code) 2016 California Fire Code (C.F .C .) (based on 2012 International Fire Code) 2016 California Energy Code (C.E .C .) 2016 California Green Building Standard Code (C.G .B .S .C .) 5.Manufacturer's Specifications all manuals to be compiled in an indexed binder format. contractor and all subcontractors shall install or apply, and protect all products, materials, processes, methods, coatings, equipment, appliances, hardware, software, etc. in strict accordance with the manufacturer's details, specifications, & instructions, typical. all manuals or instructions provided by these manufacturers for proper operation & maintenance of the above are to be delivered to the owner at the completion and final inspection of the project. PROJECT DESCRIPTION Project Summary The Owner plans to construct new main floor additions (860 s.f. heated and convert 605 sq. ft. to unheated garage) to the existing two story single family residence (approx. 4,467 s.f. heated). In conjunction with these new additions, some portions of the existing home will be remodeled (no more than 50%), with selected replacements of windows and exterior doors, roofing, exterior siding, decking and rails, stairways, and walkways. The new additions will include a new master bedroom suite, powder room, foyer, kitchen, dining, nook, stairs, an office, and a new exterior deck. The living area remodel will involve a remodeled master bath, powder room, mud room, and garage. The upper portion of the existing driveway will generally remain as is, with modifications as shown to add a parking area and a new driveway down to access the new two car garage at the lower floor, as well as several low retaining walls. Age of Existing Structures Main House built circa 1960 - 56 yrs. old Tree Protection Two ordinance size protected oak tree removals are required/ proposed by the project in order to insert the driveway. One Bay tree is recommended for removal to protect the remaining oaks and Sudden Oak Death. Extensive tree protection fencing will be required in order to protect numerous existing oak trees on the property. UWIC Fire Hazard Zone Requirements Given the structure is existing and is located in the Wildland-Urban Interface Fire Area, we understand that the Building Dept. will require the following: a .Automatic Fire Sprinkler System will be required. b .Building requirements for Wildland-Urban Interface Fire Areas, per Chapter 7 A , 2016 CBC WILL NOT APPLY. c .Fire Alarms will need to be connected to the Saratoga Fire Dept. EWAS system. Overall Gross Site Area 172,933 s.f.=3.970 Ac. minus 50' road R.O.W.96,277 s.f.=2.210 Ac. Net Site Area 76,656 s.f.=1.760 Ac. Average Slope 26.32%per Dodge Calcs Net Site Area 76,656 - Slope Reduction Factor =49%0.49 x 76,656 =39,095 s.f.=0.897 Ac. Allowable Floor Area Allowable Floor Area =4,050 s.f. 24,095/1000 round up =24 x 78 =1,872 s.f. Total Allowable Floor Area 5,922 s.f. Floor Area existing addition total Lower Floor =1,967 s.f.+(605)s.f.=1,362 s.f. Main Floor =2,235 s.f.+1,125 s.f.=3,360 s.f. Covered Porches (3 walls & roof)=265 s.f.+(265)s.f.=0 s.f. Garage =0 s.f.+605 s.f.=605 s.f. Total Floor Area =4,467 s.f.+860 s.f.=5,327 s.f. OK < 1,117 s.f. 25% Max. Allowed Addition 25%=1,117 s.f.19% 50% Max. Allowed Remodel 50%=2,234 s.f. Floor Area to be Remodeled existing total Lower Floor =853 s.f.853 s.f. Main Floor =834 s.f.834 s.f. Covered Porches =265 s.f.265 s.f. Total Remodeled Floor Area =1,952 s.f.1,952 s.f. OK < 2,234 s.f. 44% () AREA TABULATIONS TSAI RESIDENCE - 20972 Saratoga Hills Road MINUS THE R.O.W. ROAD EASEMENT (per Code Section 15-06.620) SITE 20972 Saratoga Hills Rd. Saratoga, CA 95070 PARCEL MAP N.T.S. TSAI REMODEL VICINITY MAP N.T.S. SITE Attachment 7 69 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A1.0 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 14 FEBRUARY 2017 PLANNING RESUBMITTAL1 150'-0"25'-0"20'-0" 590 580 575570565 560555550545540535530530535540545550555560565570575580590600610600 610RIGHT OF WAYEXT.SIDES.B.INT.SIDE S.B. SARA T O G A HI L L S R O A D 585 58559560 561559 5 605SEE SHEET A1.1 FOR ENLARGED SITE PLAN ROADHILL S SARA TOGA ( E ) SW A L E ( E ) SW A L E (E) S W A L E30'-0"FRONTSETBACKRIGHT OFWAY61 5 (MAIN FLR. ADDITIONS SHOWN SHADED) (E) TWO-STORY RESIDENCE 50'-0"(N) DRIVEWAY(N) DRI V E W A Y (E)(N)EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXISTING NEIGHBOR EXIST'G. POOL AND EQUIPMENT TO BE REMOVED SEE SHEET A1.1 FOR NOTES 15 TREE 6' HIGH CHAIN LINK FENCE 8' TALL, 2" DIA. GALVANIZED POSTS, DRIVEN 24" INTO THE GROUND, SPACED NO MORE THAN 10' APART SECTION TEXT EXISTING GRADE 8' TALL, 2" DIA. GALVANIZED POSTS, DRIVEN 24" INTO THE GROUND, SPACED NO MORE THAN 10' APART 6' HIGH CHAIN LINK FENCE PLAN (N) SITE PLAN SCALE: 1" = 40' TREE PROTECTION DETAIL SCALE: 1/8" = 1'-0" 1 NOTE:ALL TREE PROTECTION FENCING TO BE INSPECTED BY CITY ARBORIST PRIOR TO ISSUANCE OF BUILDING PERMITS, TREE PROTECTION FENCE DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST - KATE BEAR 408-868-1276 SIGN: 0 20'40'80' 70 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A1.1 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects SITE PLAN NOTES ■ 1. Existing and New Driveways grading & paving shall be per 2016 CRC sec. R300.2, and in accordance with 2016 CGBSC chapter 4, Division 4.1, typ., u.n.o. see Civil Engineering Drawings by Jakaby Engineering for more info. at end of project remove existing a.c. paving as shown to be removed, and provide erosion control measures. a . existing driveway: protect portions of existing asphalt driveway as much as is possible from damage throughout construction (use as staging/parking areas). maintain in usable condition at all times, and keep clear during construction as much as is possible and practical, typical, u.n.o. remove as shown or re-pave with new asphalt at end of project. b . new asphalt driveway: new asphalt driveway (as shown) - 3” A.C. paving o/ 12” class II baserock o/ properly compacted and pre-moistened sub-grade per soils report by Murray Engineers, Inc., typical, u.n.o. c . new pervious paver driveway: new interlocking pervious concrete paver driveway (as shown for parking), over 2” sand over 12” of compacted class II baserock over properly compacted & pre-moistened sub-grade per soils report by Murray Engineers, Inc. F IRE D EPT. TURNAROUND N OTE: paving design must be able to support fire truck traffic per Santa Clara County Fire Dept. standard details/specification D -1 . 2. Grading/Cut/Fill, General Surface Drainage, and Erosion Control Verify/locate any existing underground drainage lines prior to excavations. Storm water drainage and retention during construction shall be per sec. R300.1, 2016 CRC, and grading & paving shall be per sec. R300.2, 2016 CRC w/ both in accordance w/ 2016 CGBSC, chapter 4, Division 4.1, typical, u.n.o. a . grading/cut&fill: all grading, excavation, cut & fill, and compaction shall comply with City of Saratoga standards, and performed in strict accordance with the recommendations in soils report by Murray Engineers, Inc. and civil engineering drawings by Jakaby Engineering, typical, u.n.o. all grading shall be performed in such a manner as to be in compliance with standards established by the local Bay Area Air Quality Management District for airborne particulates. b . surface drainage: provide rough & finish grading for 5% min. slope (2% min. at paved areas) for 10' away from all structures (min.) per sec. R 401.3, 2016 C R C . provide 2% min. positive drainage swales as shown, typical, u.n.o. c . erosion control provide erosion control measures per sec. 4.106.2, 2016 CGBSC. see Erosion Control Plan by Jakaby Engineering for more info. 3. Landscaping/Irrigation See “DN- “ Landscape Drawings by Divine Nature Landscape Design. Must comply with California Public Resources Code 4291 or California Gov’t. Code 51182, and 2016 CBC sec. 701A .3.2.4, per Santa Clara County Fire Dept. protect any existing landscaping, shrubs, bushes, irrigation lines & valves during construction per landscape designer’s specs. remove any bushes and shrubs as required for new construction work. Maintain existing hose bibs and irrigation valves as much as possible, typical, u.n.o. contractor to perform walk through with owners prior to start of project to discuss landscape protection strategy, per sec. 4.106.3, 2016 CGBSC and irrigation relocation. NOTE: prior to Building Permit Final approval, property shall be in compliance with vegetation clearance requirements from all new, or existing, structures prescribed in sec. 4906 2016 CFC & sec. R327.1.5 2016 CRC, typical, u.n.o. 4. Trees remove existing trees as shown. no ordinance size tree, or street tree, shall be removed without a tree removal permit from the City of Saratoga, typical, u.n.o. see tree protection fence detail on sheet A 1.0 for more info. keep fences in places in place throughout construction. See Arborist’s Report dated 10/21/14 and revised on 12/7 /16 (sheet A1.1a) for numbered trees by Urban Tree Management for more info. protect existing trees shown to remain from damage during construction, including those trees located on adjacent properties. all ordinance protected trees as shown to remain shall be protected from damage during construction with 6’ tall chain link temporary protective fencing at drip line where shown, typical, u.n.o. Install tree protection fencing before construction, City Arborist must inspect all fences prio r to issuance of any and all building permits. no traffic, equipment, materials, or activity allowed inside fenced area, typical, u.n.o. 5 . Perimeter Fences protect all existing perimeter fences where shown to remain from damage during construction, typical, u.n.o. see Landscape drawings for new deer fence design and details. 6 . Utilities owner to pay any and all engineering and connection fees as required by new work. all utility line trenching shall be designed and installed in accordance with City of Saratoga standards and Arborist report, typical. coordinate with City of Saratoga and West Valley Sanitation District for any required changes to sewer lines. a . electrical/phone/cable: existing 200 amp elec. panel/meter to be replaced/ upgraded to 400 amp elec. panel to at location shown on plan. keep/protect existing overhead wires for all utilities from existing power pole as shown to meter location, verify with PG&E. see elec./mech. plans for more info, typical. b . domestic water: existing water meter to remain. verify adequacy of existing underground domestic water main feed from street, upgrade size of main as required for new automatic fire sprinkler system. c . sanitary sewer verify that existing sewer line is adequate (must be 4" dia.) to service proposed addition and remodel as required by City of Saratoga and the West Valley Sanitation District. contractor to verify existing accessible listed and approved type backwater valve on drainage piping per 2016 CPC sec. 710.0. Contractor to obtain and coordinate all necessary connection permits. d . natural gas existing gas meter to be relocated as shown on site plan. contractor to verify that existing gas main line from street is adequate to service proposed remodel as required by the City of Saratoga, and P .G .&E. typical. 7 . Public Works Notes Disposition & treatment of storm water will comply with the National Pollution Discharge Elimination System (NPDES) Standards & implementation standards established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. all building and construction related activities shall adhere to "New Development and Construction Best Management Practices" as adopted by the City of Saratoga for the purpose of preventing storm water pollution. provide new erosion control measures during construction per City of Saratoga Engineering requirements, as noted on site plan and as required per sec. 4.106.2, 2016 CGBSC. typical, u.n.o. 8 . Address Numbers per sec. R319.1, 2016 CRC & sec. 505, 2016 CFC. approved illuminated address numbers shall be placed on the building in such a position as to be plainly visible and legible from the street or road fronting the property, typical, u.n.o. 9 . Maintain Public Right of Way Improvements all adjacent property, public or private, shall be maintained in a clean, safe, & usable condition, typical. it shall be the responsibility of the owner & contractor to protect the existing paving in the public right of way, & maintain the streets, sidewalks, curb & gutter in a clean, safe, & usable condition. all spills of soil, rock, gravel, or construction debris shall be removed from the right of way during construction & upon completion of project. 10. New Walks, Porches, & Terraces all paving shall be per sec. R300.2, 2016 CRC and in accordance with 2016 CGBSC, chapter 4, Division 4.1, Install all concrete slabs over 12" non-expansive compacted baserock, over compacted/prepared subgrade per soils report by Murray Engineers, Inc., typical, u.n.o. a . new entry walk, front porch new broom finish poured concrete slabs 5” reinf. concrete slab per details, typical, u.n.o. b . terraces typical, u.n.o. stone pavers (color/size/pattern per architect's selection, and sloped per details) o/ 1" mortar bed o/ 5” reinf. concrete slab, typ., u.n.o. 11. Retaining Walls and Landscape Walls see geotechnical report by Murray Engineers, Inc. & grading/ drainage plan by Jakaby Engineering for more info. See landscape architect’s drawings, details, & cross sections for more details & specs, typical, u.n.o. a . concrete retaining walls new 5’-0” max. height board formed poured in place colored concrete retaining walls where shown. See exterior elevations for specs, and civil/structural engineering drawings and details for more info. typical, u.n.o. b . concrete landscape/garden walls new 3’-0” max. height board formed poured in place colored concrete landscape walls where shown. See exterior elevations for specs, and structural engineering drawings and details for more info. typical see landscape drawings for more info, typical, u.n.o. c . french drains at all retaining walls 4” dia. perforated pipe at base of retaining walls. slope @ 1% min., connect to underground tight line & connect to infiltration/detention structures as shown on Civil Engineering plans. 12. Roof Drainage System see exterior elevations and roof plan for more info. see Civil Engineering drawings by Jakaby Engineering. Install new fascia gutters w/ downspouts per exterior elevations/roof plans, and connect all downspouts to existing, or new 4” dia. HDPE tight lines (slope at 1% min.) and run to new infiltration/drainage structures as shown on site plan and sheet C1.1, typical, u.n.o. Disposition and treatment of stormwater will comply with the National Pollution Discharge Elimination System (NPDES) Standards and implementation standards established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 13. Setback Verification prior to first city inspection of foundation contractor to have licensed surveyor (R .C .E . or L .L .S . of record) verify and stake out new building corner locations, and provide written certification that all building setbacks are per the approved plans, typical. 1 4 . Topography/Contours See sheets T-1.0 and T-1.1. all existing property lines, bearings, trees, topography, contours, grade elevations, utilities, paving, drainage locations, etc. are based on Topography Maps as prepared by Dodge & Assoc. Surveying, dated February 12, 2014 through October 24, 2014. 15. Remove Existing Hardscape and Swimming Pool see landscape drawings by Divine Nature Landscape Design for more info. Remove existing wood retaining walls, concrete walkways, swimming pool, concrete patios, and equipment as shown dotted. remove/cap off existing water, gas, & electrical utilities, etc. infill pool using spoils cut from driveway work and house foundation excavations. Compact soils per geotechnical report by Murray Engineers, and provide erosion control measures per Civil Drawings by Jakaby Engineering, typical, u.n.o. 16. Construction Damage and Hardscape a . walk through protect all existing hardscape items shown to remain from damage during construction. verify in site walk through with owner the items to be removed or protected, typical, u.n.o. b . removal/salvage:: confirm with owner any items, tile, bricks, pavers, etc. to be salvaged and/or re-used. all other paving and hardscape to be removed shall be recycled and material weights documented as required by the City of Saratoga. 1 7 . New Wood Decks, and Stairs a . new wood deck new 5/4 IPE decking over p.t.d.f. deck joists per structural/architectural details, typical, u.n.o. b . new exterior stairs new 5/4 IPE decking treads over stair framing per structural/architectural details, typical, u.n.o. 14 FEBRUARY 2017 PLANNING RESUBMITTAL1 1 (E) 6" ORNAM. PROTECT (E) OAK TREES TO REMAIN, TYP. w/TREE PROTECTION FENCING 606 608 610 604 602 6005985965947%8%12%11%12½%10% 588 586 7%612 614 11½%14'-0" WIDE 12'-0" WIDE20'-0" 30'- 0"25'-0"±65'- 2" ±56'-4"±17'-0"±27'-2"AA1.2AA1.2BA1.2BA1.2CA1.2CA1.2DA1.3DA1.3EA1.3EA1.3FA1.3FA1.3610610(E) 30" OAK (E) 35" OAK (E) 32" OAK (E) 26" OAK (E) 24" OAK (E) 8" OAK (E)10" TREE 6026046066086 1 2 6 1 4 612614608(E)11" OAK (E)16" TREE (E) 8" OAK (E)10" OAK (E)14" TREE (E) 30" OAK (E) 24" OAK (E) 28" CYP. (E)18" CYP. (E) 8" TREE (E) TREE GROUP (E) 20" OAK (E)10" OAK (E)11" OAK (E) 8" TREE (E) 7" OAK (E)14" OAK (E) 32" OAK (E)16" OAK (E) 20" OAK (E)19" PINE (E)16" OAK(E)13" OAK (E)14" OAK (E)10" OAK (E) 20" OAK (E)12" OAK (E)11" OAK (E) 24" OAK (E) 25" OAK (E) 26" OAK (E) 28" OAK (E) 20" OAK (E)12" OAK (E)18" OAK (E) 22" OAK (E) 23" OAK (E) 21" OAK (E) 22" OAK(E)14" OAK (E)10" OAK(E) 7" OAK (E) 26" OAK (E) 7" OAK (E) 8" ACACIA GROUP (E)11" OAK (E) SWALE (E) INLET (E) GARDEN (E) INLET (E) SWALE (E) SWA L E ROADSAR A T O G AN 03°45'21" E 224.16'N 4 8 ° 2 2 '0 0 " W 3 6 . 9 9 'N 4 3 ° 5 6 ' 0 0 " W 6 6 . 5 0 'N 32° 10 '00" W 93.47 ' S 4 7 ° 4 1 '0 0 " E 8 3 . 7 7 ' S 81°59'00" E 119.50' (E)19" OAK NEW DRIVEWAY NEW DRIVEWAYINTERIOR SIDE SETBACK R.O .W .FRONT SETBACKR.O.W.EXTERIOR SIDESETBACK578 5755785805905925885865845825945 9 0 5 9 2 5 8 8 5 8 6 5 8 4 5 8 2 5 8 0 6005985965945925905885865845825805786026046066 0 8 6 1 0 6 1 2 6 1 4 (N) RET. WALL (N) R E T . W A L L (N) R E T . W A L L (E ) S W A L E (N) A/C (N) LOWER STOOP (R) #25 #26 #23 #24 #18 #22 #21 #20 #19 #37 #36 #35 #33 #34 #30 #31 #32 #16 #17 #15 #14#13 #11 #6#5#4 #7 #8 #9 #10 #1 #2 #3 (N) 6' HIGH D E E R F E N C E (N) 6' HI G H D E E R F E N C E(N) 6' HIGH DEER FENCE(N) 6' HI G H D E E R F E N C E (N ) 6' H I GH D E E R F EN C E (E) D.G. (SAND) 575 (R)#12 #39 #40 #41 #42 #43 (R) 50'- 0"50'-0"MATCH LINESEE A1.1a(N) MAIN FLR ADDITIONS OVER (E) LOWER FLOOR NEW ASPHALT PAVED DRIVEWAY EDGE OF EXISTING A.C. PAVING TO BE REMOVED REMOVE EXISTING SINGLE STORY WING (SHOWN DOTTED) REMOVE (E) WOOD RET. WALLS (DOTTED)604.15T.O. CONC.603.65T.O. CONC.NEW INTERLOCKING PERVIOUS PAVER DRIVEWAY (E) O.H. WIRES TO REMAIN, UPGRADE (E) ELECTRICAL METER TO REMAIN PROVIDE TREE PROTECTION FENCING TREE PROTECTION FENCING TYP. (N) WALKWAY 18"x36" CONC. PADS NEW WD. DECK FOUNDATION LINE PROVIDE NEW TREE PROTECTION FENCING TYP. NEW STONE TERRACE NEW STONE TERRACE PROTECT (E) 16" TREE NEW DOMESTIC WATER MAIN EXISTING GAS & SEWER LINES TO REMAIN AS IS (APPROX.) FIRE DEPT. TURNAROUND (E) SWIMMING POOL TO BE REMOVED (SHOWN DOTTED) PROVIDE TREE PROTECTION FENCING PROPOSED FENCE, TYP. REMOVE BY HAND (E) POOL EQUIP. ENCLOSURE REMOVE (E) CONC. PAD 9½% 10% 10%5% MAX.LINE ± (E) DRIP(E) DRI P LINE ± (E) D R I P LI N E ± (E) DRIPLINE ± (E) GAS METER TO BE RELOCATED (E) POLE (E) POLE GUY(SHOWN DASHED/HATCHED) (SHOWN SHADED) (E) LOWER FLOOR TO REMAIN (SHOWN DASHED) (E) MAIN FLOOR (N) MAIN FLR ADDITIONS (SHOWN SHADED) (SHOWN DASHED) (E) MAIN FLOOR (E)(N)EXISTING A.C. DRIVEWAY TO BE REMOVED (PROTECT DURING CONSTRUCTION) EDGE OF EXISTING A.C. PAVING - KEEP DURING CONSTRUCTION FOR STAGING - REMOVE AT END OF CONST. NEW 10" THICK & 36" TALL POURED CONC. LANDSCAPE WALL REMOVE (E) 15" OAK TREE PROTECT (E) 16" TREE F.P.594.00604.00F.P.604.40T.O. DECKT.O.W. 593.60B.O.W. 588.60592.80F.P.T.O.W. 593.00B.O.W. 588.00T.O.W. 588.50 B.O.W. 583.00 T.O.W. 583.5 0 B.O.W. 582.0 0T.O.W.586.80B.O.W.582.70T.O.W.588.25NEW LOCATION FOR GAS METER (E) PATHWAY TO REMAIN EXISTING FENCE TO REMAIN (E) TERRACE TO REMAIN (N) WOOD FRAMED STAIRS (E) STAIRS TO BE REMOVED, TYP. (SHOWN DOTTED) REMOVE (E) CONC. WALKS605.00F.P.NEW WALK 3x6 CONC. SLABS WALKWAY CONCRETE CURB - SEE CIVIL DRAWING 10 a 15 10 a 15 4 1a 1 1b 11b 1c 6a 4 1a 2c 17 a 15 1a 4 6d 16 16 16 5 16 a 17 b 16 15 4 4 4B.O.W.583.70T.O.W.587.00B.O.W. 581.60 T.O.W. 586.50 B.O.W. 592.00 T.O.W. 594.25 <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. NEW METAL VEHICLE GATE- (E) SAN. SEWER M.H. (E) W.M . 4 DW DW DW DW DW SS SS SS SS DW DW DW E E E E E GGGG6b 6d 6c 1 15 4 5 4 15 15 (N) PARTIAL SITE PLAN SCALE: 1" = 10' typical, u.n.o. stone pavers (color/size/pattern per architect's selection, and sloped per details) o/ 1" mortar bed o/ 5” reinf. concrete slab, typ., u.n.o. 11. Retaining Walls and Landscape Walls see geotechnical report by Murray Engineers, Inc. & grading/ drainage plan by Jakaby Engineering for more info. See landscape architect’s drawings, details, & cross sections for more details & specs, typical, u.n.o. a . concrete retaining walls new 5’-0” max. height board formed poured in place colored concrete retaining walls where shown. See exterior elevations for specs, and civil/structural engineering drawings and details for more info. typical, u.n.o. b . concrete landscape/garden walls new 3’-0” max. height board formed poured in place colored concrete landscape walls where shown. See exterior elevations for specs, and structural engineering drawings and details for more info. typical see landscape drawings for more info, typical, u.n.o. c . french drains at all retaining walls 4” dia. perforated pipe at base of retaining walls. slope @ 1% min., connect to underground tight line & connect to infiltration/detention structures as shown on Civil Engineering plans. 12. Roof Drainage System see exterior elevations and roof plan for more info. see Civil Engineering drawings by Jakaby Engineering. Install new fascia gutters w/ downspouts per exterior elevations/roof plans, and connect all downspouts to existing, or new 4” dia. HDPE tight lines (slope at 1% min.) and run to new infiltration/drainage structures as shown on site plan and sheet C1.1, typical, u.n.o. Disposition and treatment of stormwater will comply with the National Pollution Discharge Elimination System (NPDES) Standards and implementation standards established by the Santa Clara Valley Urban Runoff Pollution Prevention Program. 13. Setback Verification prior to first city inspection of foundation contractor to have licensed surveyor (R .C .E . or L .L .S . of record) verify and stake out new building corner locations, and provide written certification that all building setbacks are per the approved plans, typical. 1 4 . Topography/Contours See sheets T-1.0 and T-1.1. all existing property lines, bearings, trees, topography, contours, grade elevations, utilities, paving, drainage locations, etc. are based on Topography Maps as prepared by Dodge & Assoc. Surveying, dated February 12, 2014 through October 24, 2014. 15. Remove Existing Hardscape and Swimming Pool see landscape drawings by Divine Nature Landscape Design for more info. Remove existing wood retaining walls, concrete walkways, swimming pool, concrete patios, and equipment as shown dotted. remove/cap off existing water, gas, & electrical utilities, etc. infill pool using spoils cut from driveway work and house foundation excavations. Compact soils per geotechnical report by Murray Engineers, and provide erosion control measures per Civil Drawings by Jakaby Engineering, typical, u.n.o. 16. Construction Damage and Hardscape a . walk through protect all existing hardscape items shown to remain from damage during construction. verify in site walk through with owner the items to be removed or protected, typical, u.n.o. b . removal/salvage:: confirm with owner any items, tile, bricks, pavers, etc. to be salvaged and/or re-used. all other paving and hardscape to be removed shall be recycled and material weights documented as required by the City of Saratoga. 1 7 . New Wood Decks, and Stairs a . new wood deck new 5/4 IPE decking over p.t.d.f. deck joists per structural/architectural details, typical, u.n.o. b . new exterior stairs new 5/4 IPE decking treads over stair framing per structural/architectural details, typical, u.n.o. "Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans." "Disposition and treatment of stormwater will comply with the National Pollution Discharge Elimination System ("NPDES") Standards and implementation standards established by the Santa Clara Valley Urban Runoff Pollution Prevention Program" SEE SHEET A1.1a FOR MORE AREA 71 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A1.1a 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 14 FEBRUARY 2017 PLANNING RESUBMITTAL1 1 | Page Tree Survey of 20972 Saratoga Hills Road Saratoga CA 95070 12/7/2016 Prepared by: Michael P. Young Certified Arborist WC ISA #623 2 | Page 12/7/16 20972 Saratoga Hills Road Saratoga, CA 95070 To Whom It May Concern: Assignment It was our assignment to physically inspect and tag all native trees over 6” in diameter and all trees over 10’ in diameter in the survey area, and write a tree survey report. Reference materials included a site plan provided by the client. It was also our assignment to review the Plan Set dated 10/19/16 from Noel Cross Architects, meet at the site and comment as to how best protect the trees and build the project. Summary This survey provides a numbered map and complete and detailed information about each tree surveyed. There were 48 trees surveyed, with 46 of these classed as protected trees under the City of Saratoga’s tree ordinances. Most of the species are native oaks. Oak #15 needs to be removed in order to shore up a failing support wall for the home. One small bay should be removed due to proximity to coast live oaks and the bay’s status as a carrier of SOD (see Note on Oaks section in this report and referenced webpage in data table). Three protected trees are recommended for removal due to poor structure/safety concerns, but these are Arborist recommendations and at this time the owner has not directed us to pursue removal of these trees. Another tree (oak #19) is recommended for a full hazard assessment due to safety concerns. The total assessed value of all trees on site is $338,140.00. Tress #: 1-9, 11, 12, 15 – 18, 23 – 26, 39 – 48 are all near proposed construction and their value totals: $236,740.00. A 25% security deposit will be due to the city for $59,185.00. Method All the trees surveyed were examined and then rated based on their individual health and structure according to the following table. 3 | Page KEY Health Structure Good excellent/vigorous flawless Fair/good healthy very stable Fair fair routine maintenance needed Fair/poor declining mitigation needed Poor dead or near dead hazard The trunks of the trees are measured using a standard measuring tape at 4 ½ feet above soil grade (referred to as DBH or Diameter at Breast Height), except those specimens whose form does not allow for a representative measurement at this height. The measurement for multi- stem specimens is taken below the lowest fork on the trunk when possible in accordance with the International Society of Arboriculture Standards. The canopy height and spread are estimated using visual references only. The complete list of trees and all relevant information, including their ratings, their “Protected Tree” status (X = protected) and recommendations for their care, can be found in the data table that accompanies this report. Tree Valuations We were also asked to prepare a Value Assessment concerning the 48 trees on this property, which are included in an Arborist’s Report prepared by Urban Tree Management, Inc. The method used for the appraisal of the 48 trees is the Trunk Formula Method, in accordance with the International Society of Arboriculture (ISA), Guide for Plant Appraisal, 9th Edition. The ISA Western Chapter Species Classification Guide is used to provide species ratings and to provide trunk values per square inch, which is part of the trunk formula method. I have used an Excel spreadsheet, which is attached, to perform the calculations. General Issues and Recommendations Tree Structure Consistent structural pruning to reduce the number of poorly attached leaders is an industry best practice. It reduces the incidence of limbs tearing from the trunk due to weight or weather, and fewer limb tears reduces the incidence of tear-based central trunk decay. Ideally, structural pruning is done when the tree is young, because young trees respond more quickly and only smaller diameter cuts are necessary. It appears that most of the trees on this property have never been pruned for structure. This has resulted in trees that have multiple poorly attached leaders and large limb tears. Trees are also somewhat crowded together. This has resulted in many trees located under or growing through other tree canopies. Many of these subordinated trees exhibit severe leans from their efforts to grow toward available sunlight. Hard structural pruning of mature trees defeats the purpose of increasing a tree’s safety. This is 4 | Page because mature trees have difficulty healing large diameter cuts and the open cuts tend to decay into larger hollows in adjacent limbs and the trunk, making the tree more prone to failure. The primary way to improve structure in mature trees is targeted structural pruning to subordinate specific (smaller diameter) limbs and force growth to the main leader. For trees with one leaning main stem, this is not workable and the solution is to simply reduce end weight overall, thus relieving some pressure on the trunk and root system. These are a few of the techniques recommended for trees at this property. For all trees, notes on the tree’s condition and recommended health improvement techniques and/or structural corrections are recommended in the notes section of the accompanying data sheet. Specific Trees This site is surrounded by trees. There are several areas on site that it will simply be easier to have a Certified Arborist on site and/or have a Field Meeting with the contractors before each task near trees, than it is to write up specific protection measures. These areas are all noted below and shall be noted on the Plans as well. A drainage dissipater will be installed somewhat near trees #4, #6, #9 & #11. The installation of the dissipater must be done under the direct supervision of the Project Arborist. All trenching must be done in an exploratory method initially, in order to preserve anchorage roots of the tree (2” diameter +). No tree should need to be removed to install these dissipaters. A Fire Truck turnaround is mandated on this site. This will be done between trees #7 & #34. The fire truck turnaround will be approximately 18’ away from tree #7 and some fill will be added under this tree to accommodate the turnaround. Tree #24 will need a slight grade cut and only approximately 10% of its canopy will be impacted by the activity. A Field meeting must occur before grading begins so we can explain the importance of the tree roots to the crew. Tree Protection Fencing must be installed before grading and must be installed 2-3’ in from the proposed fire truck turnaround. There is a new “Breakfast Nook” planned near trees #7 & #8. This new construction will be moving the structure farther from tree #7. The new work near tree #8 will be cantilevered towards the tree (avoiding the need for extensive foundation work under this tree). The foundation of this part of the home will be built on piers with grade beams. The engineers/contractors are instructed to locate the foundation so no roots (2” diameter +) need to be removed. Careful exploratory trenching may need to be done ahead of time to determine if there is a root/foundation conflict. A Field Meeting must occur before excavation is done for this part of the building. Tree #19 has a large hollow in its base from a large cut made in the past that has decayed into the trunk. The tree is adjacent to and leaning over the home and the extent of the decay cannot be judged from the exterior or from sounding with a mallet. If the owner would like to retain the tree, a hazard assessment is recommended. This entails drilling a few targeted holes in the trunk to determine the extent of rot affecting the tree. 5 | Page Trees #20 and #26 are interlinked via tree #26 acting as a prop for a very heavy limb from tree #20. This can’t go on forever. One of the two will fail. The prop point is over a stair to the pool and this problem could be corrected by placing a (very tall) steel prop for tree 20’s limb. This prop could potentially be worked into a stairway rail or other decorative item. Another option is cutting back the limb on tree #20 severely to the next upright branch. However, because of the large diameter of this cut, it is unlikely to heal properly and may cause rot in the limb over time. The new driveway approach is actually moving farther away from trees #1 - #3. The driveway is coming closer to tree #33 (it will be about 5’ from this tree). This is a 15” DBH Valley Oak in Fair – Good Health and with a Field Meeting beforehand, this tree shall be fine. The driveway will then be demolished and rebuild between trees #7/#8 & #4/#5/#6/#9 (see images to right). A Field Meeting shall occur before demolition of the current driveway. This area has been previously impacted by the existing driveway so the likelihood of additional significant root damage is unlikely. Most of the work will be fill instead of cut, so damages are expected to be minimal. There are old failing retaining walls near trees #9, #11, #12 & #15. The Architect tells me there is no way to build these walls near tree #15 so a request for removal is being made for this tree. The City of Saratoga Criteria that are met, to justify this removal, are Criteria #4, #5 & #6. There are many trees on site and the removal of 1 tree will not negatively impact the whole forest (#4). The forest as a whole is very dense and the removal of one tree allows surrounding trees to reach a more full potential (#5). I have reviewed the failing retaining walls with the Architect. The walls are necessary. While there are several other trees in the area, the removal of one tree is needed in order to rebuild the necessary wall and there are no alternative construction techniques that allow for its retention (#6). The appraised value for this tree is $9100.00 and so $9100.00 of new trees must be planted on site as mitigation. The retaining wall near trees #9, #11 & #12 will need to be carefully excavated under our supervision. The wall shall be designed to be supported with piers that are located in a way that they do not cut any roots 2” diameter +. We shall closely monitor the proposed layout and installation of these walls. Tree #9 needs a Root Collar Excavation during this process and the root collar shall remain exposed after the walls are installed. 6 | Page The old pool, pool equipment and cement pad will be demolished. These are all surrounding tree #41 (see image to right). The demolition shall be done under our supervision. The demo equipment shall avoid repeatedly driving over the root systems. It is likely that a temporary road will need to be built to get materials out of this area. I recommend the road go between trees #18/#16 & #17. I shall advise on the least impactful way to accomplish this once I know the requirements of the machinery and the temporary road. I shall insure the trees survive this process. Tree Health The majority of trees appear to be in fair or fair/good health. Most of those trees classed as in only fair health are less vigorous primarily due to shading by larger trees. Many of the larger oaks here also appear to under significant stress due to lack of water. Dead branches and poor growth intervals are apparent. A stressed tree is an easier pathway for disease and insects. Any large Oaks that are to be retained should be watered (under the dripline area) to a depth of 12-18’ once every 6 weeks during the dry season. Many of the oaks here are at risk for ground-based fungal infections because their trunks (barked area above the buttress roots) are buried under soil and debris. It appears that the large dead Valley Oak died due to this type of infection (Oak Root Fungus). Root collar excavations (RCEs) are recommended for virtually all the trees on the property to discourage fungal pathogens and insects from entering the tree above the root system (see other techniques in section below). Note on Oaks There are two deadly fungal diseases in the local area that property owners should be aware of: Oak Root Fungus (ORF) and Sudden Oak Death (SOD). Many native oaks in Central California and in and around Silicon Valley have succumbed to these diseases and best management practices are encouraged. As mentioned above, the large dead Valley Oak at this address was likely a victim of ORF. Basic techniques to safeguard oaks and other trees include excavating the root collars of all oaks (as mentioned earlier in this report), using bubblers or drip systems that do not directly spray trunks (dry trunks discourage fungal growth); and clearing bays from areas near oaks (they are carriers of SOD). The California Oak Mortality Task Force recommends that bays be cleared if within 15’ of the trunks of SOD susceptible oaks. Tree #10, a 7” diameter bay is 15-20’ from the trunk of Coast Live Oak #4 and is recommended for removal. Coast Live Oaks are particularly vulnerable to SOD, so planting of SOD-resistant species is encouraged when planning for additional trees. Information on choosing and managing oaks in known SOD areas can be found at the California Oak Mortality Task Force website at http://www.suddenoakdeath.org/diagnosis-and-management/best-management- practices/. Any plants that are planted inside the drip-lines of oak trees must be of species that are compatible with the environmental and cultural requirements of oak trees. A publication detailing plants compatible with California native oaks can be obtained from the California Oak 7 | Page Foundation at http://www.californiaoaks.org/ExtAssets/CompatiblePlantsUnder&AroundOaks.pdf. Local Regulations Governing Trees The Saratoga Municipal Code defines a protected tree as: (a) Any native tree having a DBH of six (6) inches or greater including Big Leaf Maple, CA Buckeye, Douglas Fir, Coast Redwood, Black Oak, Blue Oak, Coast Live Oak, Valley Oak, Tan Oak and Scrub Oak. (b) Any other tree having a DBH of ten (10) inches or greater. Thirty-six of the thirty-eight trees at this site are considered “protected” trees under this ordinance. Three of these are protected trees are recommended for removal due to poor structure/safety concerns. Risks to Trees by Construction Besides the above-mentioned health and structure-related issues, the trees at this site could be at risk of damage by construction or construction procedures that are common to most construction sites. These procedures may include the dumping or the stockpiling of materials over root systems; the trenching across the root zones for utilities or for landscape irrigation; or the routing of construction traffic across the root system resulting in soil compaction and root dieback. It is therefore essential that Tree Protection Fencing be used as per the Architectural drawings. In constructing underground utilities, it is essential that the location of trenches be done outside the drip lines of trees except where approved by the Arborist. Trenching inside the drip lines of significant trees should be done by hand. Protection Recommendations Based on the existing development, planned construction and the condition and location of trees present on site, the following is recommended: 1. Any roots exposed during construction activities that are larger than 2 inches in diameter should not be cut or damaged until the project Arborist has an opportunity to assess the impact that removing these roots could have on the trees. 2. A Certified Arborist should supervise any excavation activities within the tree protection zone of trees to be retained. 8 | Page 3. The area under the drip line of trees should be thoroughly irrigated to a soil depth of 28” every 3-4 weeks during the dry months. Utility Installation There are no new utilities (near trees) proposed for the site except for perhaps the water line. This has yet to be discovered. If new utility lines are to be installed near trees, they should be routed along the edge of the paved surfaces that are farthest from trees. Any roots exposed during these construction activities that are larger than 2 inches in diameter should be left for the Arborist to see and ok, before removal. Exposed roots shall be covered with burlap and kept moist. Typically wetting the burlap in the morning and the end of the workday is sufficient. A Certified Arborist must pre-approve the cutting of roots greater than 2” in diameter. General Tree Protection Plan It is required that protective fencing is provided during the construction period to protect those trees that are planned to be preserved. This fencing must protect a sufficient portion of the root zone to be effective. In most cases, it would be essential to locate the fencing a minimum radius distance of 6 times the trunk diameter in all directions from the trunk. There are areas where we will amend this distance based upon proposed construction. In my experience, the protective fencing must: a. Consist of chain link fencing having a minimum height of 6 feet. b. Be mounted on steel posts driven approximately 2 feet into the soil. c. Fencing posts must be located a maximum of 10 feet on center. d. Protective fencing must be installed prior to the arrival of materials, vehicles, or equipment. e. Protective fencing must not be moved, even temporarily, and must remain in place until all construction is completed, unless approved be a certified arborist. There must be no grading, trenching, or surface scraping inside the driplines of protected trees, unless specifically approved by a Certified Arborist. Trenches for any underground utilities (gas, electricity, water, phone, TV cable, etc.) must be located outside the driplines of protected trees, unless approved by a Certified Arborist. Arborist –approved trenching inside the drip lines of significant trees should be done by hand. Alternative methods of installation may be suggested. Mulch should cover all bare soils within the tree protection fencing. This material must be 6-8 inches in depth after spreading, which must be done by hand. I prefer course wood chips because it is organic, and degrades naturally over time. 9 | Page Appropriate tree wells should be constructed around trees to protect against fill. Loose soil and mulch must not be allowed to slide down slope to cover the root zones or the root collars of protected trees. Materials must not be stored, stockpiled, dumped, or buried inside the driplines of protected trees. Excavated soil must not be piled or dumped, even temporarily, inside the driplines of protected trees. Any pruning must be done by a Company with an Arborist Certified by the ISA (International Society of Arboriculture) and according to ISA, Western Chapter Standards, 1998. Repair of existing, or future landscape irrigation trenches must be a minimum distance of 10 times the trunk diameter from the trunks of protected trees unless otherwise noted and approved by the Arborist. Repair of existing, or any future, landscape irrigation trenches must be designed to avoid water striking the trunks of trees, especially oak trees. Landscape materials (cobbles, decorative bark, stones, fencing, etc.) must not be installed directly in contact with the bark of trees because of the risk of serious disease infection. Any plants that are planted inside the driplines of oak trees must be of species that are compatible with the environmental and cultural requirements of oak trees. A publication detailing plants compatible with California native oaks can be obtained from the California Oak Foundation, 1212 Broadway, Suite 810, Oakland, CA 94612. ********** I certify that the information contained in this report is correct to the best of my knowledge and that this report was prepared in good faith. Please call me if you have questions or if I can be of further assistance. Respectfully, Michael P. Young & Allie Strand Site Tree Value Assessment California Prepared by Michael Bench Consulting Arborist 2014 Species Group DBH Area 1 Trunk 2 Area2 Trunk 3 Area 3 In. Sq. Replace In. Sq. Price In. Sq. BASIC VALUE Species % Condition % Location % Un-rounded Value Rounded Value Cupressus macrocarpa 2 35 928 0 0 928.1 2.24 77.04 $71,676 50%50%70%$12,543 $12,500 Cupressus macrocarpa 2 20 314 0 0 314.0 2.24 77.04 $24,363 50%50%70%$4,264 $4,260 Ligustrum japonicum 3 7 38 6 28 5 20 62.4 3.80 45.46 $3,010 30%50%70%$316 $320 Quercus agrifolia 3 28 615 0 0 615.4 3.80 45.46 $28,151 90%70%70%$12,414 $12,400 Quercus agrifolia 3 9 64 0 0 63.6 3.80 45.46 $3,063 90%60%70%$1,158 $1,160 Quercus lobata 2 27 572 0 0 572.3 2.24 77.04 $44,260 90%60%70%$16,730 $16,700 Quercus lobata 2 32 788 0 0 787.6 2.24 77.04 $60,847 90%60%70%$23,000 $23,000 Quercus lobata 2 33 835 0 0 835.1 2.24 77.04 $64,508 90%60%70%$24,384 $24,400 Quercus lobata 2 26 531 15 177 0 619.0 2.24 77.04 $47,859 90%60%70%$18,091 $18,100 Umbellularia californica 2 7 38 0 0 38.5 2.24 77.04 $3,136 70%60%70%$922 $920 Quercus lobata 2 16 201 0 0 201.0 2.24 77.04 $15,655 90%70%70%$6,904 $6,900 Umbellularia californica 2 15 177 0 0 176.6 2.24 77.04 $13,780 70%40%70%$2,701 $2,700 Quercus lobata 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%60%70%$3,357 $3,360 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%60%70%$14,353 $14,400 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%60%70%$4,546 $4,550 Quercus agrifolia 3 21 346 0 0 346.2 3.80 45.46 $15,910 90%70%70%$7,016 $7,000 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%60%70%$5,209 $5,200 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%60%70%$13,233 $13,200 Quercus agrifolia 3 23 415 0 0 415.3 3.80 45.46 $19,051 90%70%70%$8,401 $8,400 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 3 26 531 0 0 530.7 3.80 45.46 $24,297 90%70%70%$10,715 $10,700 Quercus agrifolia 3 24 452 0 0 452.2 3.80 45.46 $20,728 90%70%70%$9,141 $9,100 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%70%70%$16,745 $16,700 Quercus lobata 2 17 227 0 0 226.9 2.24 77.04 $17,651 90%70%70%$7,784 $7,800 Quercus lobata 2 34 882 0 0 881.9 2.24 77.04 $68,118 90%30%70%$12,874 $12,900 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus agrifolia 3 11 95 0 0 95.0 3.80 45.46 $4,491 90%70%70%$1,980 $1,980 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%70%70%$6,077 $6,100 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%70%70%$1,036 $1,040 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%70%70%$1,783 $1,780 Quercus kelloggii 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%70%70%$5,304 $5,300 Pinus radiata 4 9 64 0 0 63.6 4.75 36.36 $2,485 30%50%70%$261 $260 Tree is gone Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus agrifolia 2 39 1106 0 0 1106.2 2.24 77.04 $85,392 90%50%70%$26,898 $26,900 Quercus agrifolia 2 7 38 0 0 38.5 2.24 77.04 $3,136 90%60%70%$1,185 $1,190 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%60%70%$1,528 $1,530 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%30%60%$1,008 $1,010 Quercus agrifolia 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%30%60%$1,439 $1,440 Aesculus califonica 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%60%60%$761 $760 Total =$338,140.00 TREE EVALUATION DATE 7-Dec-16 NAME Kevin Tsai ADDRESS 20972 Saratoga Hills, Saratoga CA 95070 PROTECTED TREE NO.SPECIES DIAMETER WIDTH/HEIGHTHEALTH STRUCTURE STATUS (X) **NOTES 1 Monterey Cypress 35 24/30 F F X Poorly topped and pruned from power lines 2 Monterey Cypress 20 14/25 F F X Poorly topped and pruned from power lines 3 Privet 5,6,7 15/20 F F X 4 Coast Live Oak 28 36/40 FG F X Boring insects, leaning, Rec spray program, EWR, RCE 5 Coast Live Oak 9 10/30 F F X Hollow at base from old tear, growing thru canopy of tree 6, Rec REMOVAL 6 Valley Oak 27 36/60 F FP X Large deadwood, Poorly attached codominant leaders at 8' ,Rec 1 cable, DWR, RCE, 7 Valley Oak 32 32/60 F FP X Large deadwood, poorly attached leader, Rec EWR, 1 cable, RCE 8 Valley Oak 33 50/60 F FP X Poorly attached codominant leaders at 10 ', one leader leaning over house, rec 1 cable, EWR, RCE 9 Valley Oak 15,26 50/60 F F X 10 Bay 7 15/35 FG F Bays can carry SOD, Canopy is within 15' of Coast Live Oak #4, Rec REMOVAL per California Oak Mortality Task Fore rcs: http://www.suddenoakdeath.org/wp-content/uploads/2010/08/arborist-6-10.pdf 11 Valley Oak 16 30/40 FP F X Leaning, large dead wood, Rec EWR 12 Bay 15 15/30 FG F X Leaning, large dead wood, adjoined at base with oak #12, growing into canopies of adjacent oak, REC REMOVAL 13 Valley Oak 12 40/25 F FP X Leaning severely, Rec prop if tree is valued, RCE on side away from creek 14 Valley Oak 25 30/60 F F X Leaning, large deadwood, Rec DWR 15 Valley Oak 18 40/60 FP FP X Leaning, rec EWR in direction of lean, RCE, Removal of Construction debris at base to relieve pressure on root zone 16 Valley Oak 14 30/35 F FP X Leaning, rec EWR in direction of lean, RCE 17 Coast Live Oak 21 30/55 FG FP X Leaning over creek, Rec EWR on creek side. 18 Valley Oak 15 30/50 F FP X Leaning, large deadwood, Rec EWR, DWR, RCE 19 Valley Oak 24 42/75 F FP X Leaning towards home, large hollow at base where limb was removed, poorly attached leaders at 35', Rec 1cable, EWR over home REC HAZARD ASSESSMENT to deteermine if REMOVAL is warranted. 20 Coast Live Oak 23 45/55 FG FP X Very heavy limb propped on another tree, tree Leaning towards pool and over stairway, poorly attached leaders at 8', REC severe EWR, or some EWR and specialized prop. 21 Valley Oak 10 20/40 F F X 22 Valley Oak 11 16/35 F F X Superficial hollow at base 23 Valley Oak 18 25/45 F F X 24 Valley Oak 10 25/25 FG FP X Leaning strongly, Rec EWR 25 Coast Live Oak 26 40/40 FG FP X Leaning strongly , Rec prop, EWR 26 Coast Live Oak 24 36/50 FG FP X Leaning towards stairway, propping tree #20, substantial rot in leader going towards pool, Rec, remove tree #20 from this tree, EWR on leader nearest pool 27 Valley Oak 25 30/50 FG FP X Large deadwood, leaning towards home, rec DWR, RCE, EWR 28 Valley Oak 17 35/40 FG FP X Leaning strongly over patio, growing into adjacent tree canopies, Rec prop, EWR, RCE, or REMOVAL 29 Valley Oak 34 45/70 P P X Dead, suspect ORF, Rec REMOVAL 30 Valley Oak 19 20/35 FG F X Many dead branches, Broken top, Rec RCE, DWR 31 Valley Oak 19 34/30 FG FP X Leaning strongly, Rec prop, EWR, RCE 32 Coast Live Oak 11 16/30 FG F X REC RCE 33 Valley Oak 15 25/35 FG F X 34 Coast Live Oak 10 12/20 FG F X 35 Coast Live Oak 6 12/20 FG F X 36 Coast Live Oak 8 14/25 FG F X Leaning, rec EWR on lean side, develpment of balancing leader from shoots opposite lean. 37 Black oak 14 18/35 FG FP X Multiple poorly attached leaders, Rec SP, 38 Monterey Pine 9 12/35 F FP This tree has died since our 2014 visit and was removed. 39 Valley Oak 24 60/60 G FP X Codominant Leaders 40 Valley Oak 24 50/60 G FP X Codominant Leaders 41 Coast Live Oak 39 60/70 FP FP X Codominant Leaders & thin canopy 42 Coast Live Oak 7 20/15 G FG X 43 Valley Oak 11 20/20 F FP X Codominant Leaders 44 Coast Live Oak 8 20/15 F FP X Leans 45 Coast Live Oak 7,7,10 20/20 F FP X Codominant Leaders 46 Coast Live Oak 10 20/15 F P X Topped 47 Coast Live Oak 12 20/15 F P X Topped 48 Buckeye 5,6 15/15 F FP X Codominant Leader Protected Trees =46 ** Applicable Local Tree Regulations: The Saratoga MunicIpal Code defines a protected tree as 1) any native tree with a DBH of 6" or greater including: Big Leaf Maple, CA Buckeye, Douglas Fir, Black Oak, Blue Oak, Coast Live Oak, Valley Oak, Tan Oak Scrub Oak Coast Redwood 2) All other species with a DBH of 10" or greater Based on these regulations 46 trees are protected. EWR - End Weight Reduction: pruning to remove weight from limb ends, thus reducing the potential for limb failure RCE - Root Collar Excavation: excavating a small area around a tree that is currently buried by soil or refuse above buttress roots, usually done with a hand shovel. SP - Structural pruning - removal of selected non-dominant leaders in order to balance the tree RATINGS KEY health structure good excellent/vigorous flawless fair/good healthy very stable fair fair routine maintenance needed fair/poor declining mitigation needed poor dead or near dead hazard Common Name Latin Name Bay Laurus nobilis Black Oak Quercus velutina Coast Live Oak Quercus Agrifolia Monterey Cypress Hesperocyparis macrocarpa Monterey Pine Pinus radiata Privet Ligustrum sp. Valley Oak Quercus lobata Buckeye Aesculus californica TREE EVALUATION DATE 7-Dec-16NAMEKevin TsaiADDRESS20972 Saratoga Hills, Saratoga CA 95070 PROTECTEDTREE NO.SPECIES DIAMETER WIDTH/HEIGHTHEALTH STRUCTURE STATUS (X) **NOTES1Monterey Cypress 35 24/30 F F X Poorly topped and pruned from power lines2Monterey Cypress 20 14/25 F F X Poorly topped and pruned from power lines3Privet5,6,7 15/20 F F X4Coast Live Oak 28 36/40 FG F X Boring insects, leaning, Rec spray program, EWR, RCE5Coast Live Oak 9 10/30 F F X Hollow at base from old tear, growing thru canopy of tree 6, Rec REMOVAL6Valley Oak 27 36/60 F FP X Large deadwood, Poorly attached codominant leaders at 8' ,Rec 1 cable, DWR, RCE,7 Valley Oak 32 32/60 F FP X Large deadwood, poorly attached leader, Rec EWR, 1 cable, RCE8Valley Oak 33 50/60 F FP X Poorly attached codominant leaders at 10 ', one leader leaning over house, rec 1 cable, EWR, RCE9Valley Oak 15,26 50/60 F F X10Bay715/35 FG F Bays can carry SOD, Canopy is within 15' of Coast Live Oak #4, Rec REMOVAL per California Oak Mortality Task Fore rcs: http://www.suddenoakdeath.org/wp-content/uploads/2010/08/arborist-6-10.pdf11Valley Oak 16 30/40 FP F X Leaning, large dead wood, Rec EWR 12 Bay 15 15/30 FG F X Leaning, large dead wood, adjoined at base with oak #12, growing into canopies of adjacent oak, REC REMOVAL 13 Valley Oak 12 40/25 F FP X Leaning severely, Rec prop if tree is valued, RCE on side away from creek 14 Valley Oak 25 30/60 F F X Leaning, large deadwood, Rec DWR 15 Valley Oak 18 40/60 FP FP X Leaning, rec EWR in direction of lean, RCE, Removal of Construction debris at base to relieve pressure on root zone 16 Valley Oak 14 30/35 F FP X Leaning, rec EWR in direction of lean, RCE 17 Coast Live Oak 21 30/55 FG FP X Leaning over creek, Rec EWR on creek side. 18 Valley Oak 15 30/50 F FP X Leaning, large deadwood, Rec EWR, DWR, RCE 19 Valley Oak 24 42/75 F FP X Leaning towards home, large hollow at base where limb was removed, poorly attached leaders at 35', Rec 1cable, EWR over home REC HAZARD ASSESSMENT to deteermine if REMOVAL is warranted. 20 Coast Live Oak 23 45/55 FG FP X Very heavy limb propped on another tree, tree Leaning towards pool and over stairway, poorly attached leaders at 8', REC severe EWR, or some EWR and specialized prop. 21 Valley Oak 10 20/40 F F X 22 Valley Oak 11 16/35 F F X Superficial hollow at base 23 Valley Oak 18 25/45 F F X 24 Valley Oak 10 25/25 FG FP X Leaning strongly, Rec EWR 25 Coast Live Oak 26 40/40 FG FP X Leaning strongly , Rec prop, EWR 26 Coast Live Oak 24 36/50 FG FP X Leaning towards stairway, propping tree #20, substantial rot in leader going towards pool, Rec, remove tree #20 from this tree, EWR on leader nearest pool 27 Valley Oak 25 30/50 FG FP X Large deadwood, leaning towards home, rec DWR, RCE, EWR 28 Valley Oak 17 35/40 FG FP X Leaning strongly over patio, growing into adjacent tree canopies, Rec prop, EWR, RCE, or REMOVAL 29 Valley Oak 34 45/70 P P X Dead, suspect ORF, Rec REMOVAL 30 Valley Oak 19 20/35 FG F X Many dead branches, Broken top, Rec RCE, DWR 31 Valley Oak 19 34/30 FG FP X Leaning strongly, Rec prop, EWR, RCE 32 Coast Live Oak 11 16/30 FG F X REC RCE 33 Valley Oak 15 25/35 FG F X 34 Coast Live Oak 10 12/20 FG F X 35 Coast Live Oak 6 12/20 FG F X 36 Coast Live Oak 8 14/25 FG F X Leaning, rec EWR on lean side, develpment of balancing leader from shoots opposite lean. 37 Black oak 14 18/35 FG FP X Multiple poorly attached leaders, Rec SP, 38 Monterey Pine 9 12/35 F FP This tree has died since our 2014 visit and was removed. 39 Valley Oak 24 60/60 G FP X Codominant Leaders 40 Valley Oak 24 50/60 G FP X Codominant Leaders 41 Coast Live Oak 39 60/70 FP FP X Codominant Leaders & thin canopy 42 Coast Live Oak 7 20/15 G FG X 43 Valley Oak 11 20/20 F FP X Codominant Leaders 44 Coast Live Oak 8 20/15 F FP X Leans 45 Coast Live Oak 7,7,10 20/20 F FP X Codominant Leaders 46 Coast Live Oak 10 20/15 F P X Topped 47 Coast Live Oak 12 20/15 F P X Topped 48 Buckeye 5,6 15/15 F FP X Codominant Leader Protected Trees =46 ** Applicable Local Tree Regulations: The Saratoga MunicIpal Code defines a protected tree as 1) any native tree with a DBH of 6" or greater including: Big Leaf Maple, CA Buckeye, Douglas Fir, Black Oak, Blue Oak, Coast Live Oak, Valley Oak, Tan Oak Scrub Oak Coast Redwood 2) All other species with a DBH of 10" or greater Based on these regulations 46 trees are protected. EWR - End Weight Reduction: pruning to remove weight from limb ends, thus reducing the potential for limb failure RCE - Root Collar Excavation: excavating a small area around a tree that is currently buried by soil or refuse above buttress roots, usually done with a hand shovel. SP - Structural pruning - removal of selected non-dominant leaders in order to balance the tree RATINGS KEY health structure good excellent/vigorous flawless fair/good healthy very stable fair fair routine maintenance needed fair/poor declining mitigation needed poor dead or near dead hazard Common Name Latin Name Bay Laurus nobilis Black Oak Quercus velutina Coast Live Oak Quercus Agrifolia Monterey Cypress Hesperocyparis macrocarpa Monterey Pine Pinus radiata Privet Ligustrum sp. Valley Oak Quercus lobata Buckeye Aesculus californica Site Tree Value Assessment California Prepared by Michael Bench Consulting Arborist 2014 Species Group DBH Area 1 Trunk 2 Area2 Trunk 3 Area 3 In. Sq. Replace In. Sq. Price In. Sq. BASIC VALUE Species % Condition % Location % Un-rounded Value Rounded Value Cupressus macrocarpa 2 35 928 0 0 928.1 2.24 77.04 $71,676 50%50%70%$12,543 $12,500 Cupressus macrocarpa 2 20 314 0 0 314.0 2.24 77.04 $24,363 50%50%70%$4,264 $4,260 Ligustrum japonicum 3 7 38 6 28 5 20 62.4 3.80 45.46 $3,010 30%50%70%$316 $320 Quercus agrifolia 3 28 615 0 0 615.4 3.80 45.46 $28,151 90%70%70%$12,414 $12,400 Quercus agrifolia 3 9 64 0 0 63.6 3.80 45.46 $3,063 90%60%70%$1,158 $1,160 Quercus lobata 2 27 572 0 0 572.3 2.24 77.04 $44,260 90%60%70%$16,730 $16,700 Quercus lobata 2 32 788 0 0 787.6 2.24 77.04 $60,847 90%60%70%$23,000 $23,000 Quercus lobata 2 33 835 0 0 835.1 2.24 77.04 $64,508 90%60%70%$24,384 $24,400 Quercus lobata 2 26 531 15 177 0 619.0 2.24 77.04 $47,859 90%60%70%$18,091 $18,100 Umbellularia californica 2 7 38 0 0 38.5 2.24 77.04 $3,136 70%60%70%$922 $920 Quercus lobata 2 16 201 0 0 201.0 2.24 77.04 $15,655 90%70%70%$6,904 $6,900 Umbellularia californica 2 15 177 0 0 176.6 2.24 77.04 $13,780 70%40%70%$2,701 $2,700 Quercus lobata 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%60%70%$3,357 $3,360 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%60%70%$14,353 $14,400 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%60%70%$4,546 $4,550 Quercus agrifolia 3 21 346 0 0 346.2 3.80 45.46 $15,910 90%70%70%$7,016 $7,000 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%60%70%$5,209 $5,200 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%60%70%$13,233 $13,200 Quercus agrifolia 3 23 415 0 0 415.3 3.80 45.46 $19,051 90%70%70%$8,401 $8,400 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 3 26 531 0 0 530.7 3.80 45.46 $24,297 90%70%70%$10,715 $10,700 Quercus agrifolia 3 24 452 0 0 452.2 3.80 45.46 $20,728 90%70%70%$9,141 $9,100 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%70%70%$16,745 $16,700 Quercus lobata 2 17 227 0 0 226.9 2.24 77.04 $17,651 90%70%70%$7,784 $7,800 Quercus lobata 2 34 882 0 0 881.9 2.24 77.04 $68,118 90%30%70%$12,874 $12,900 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus agrifolia 3 11 95 0 0 95.0 3.80 45.46 $4,491 90%70%70%$1,980 $1,980 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%70%70%$6,077 $6,100 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%70%70%$1,036 $1,040 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%70%70%$1,783 $1,780 Quercus kelloggii 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%70%70%$5,304 $5,300 Pinus radiata 4 9 64 0 0 63.6 4.75 36.36 $2,485 30%50%70%$261 $260 Tree is gone Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus agrifolia 2 39 1106 0 0 1106.2 2.24 77.04 $85,392 90%50%70%$26,898 $26,900 Quercus agrifolia 2 7 38 0 0 38.5 2.24 77.04 $3,136 90%60%70%$1,185 $1,190 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%60%70%$1,528 $1,530 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%30%60%$1,008 $1,010 Quercus agrifolia 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%30%60%$1,439 $1,440 Aesculus califonica 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%60%60%$761 $760 Total =$338,140.00 Site Tree Value Assessment California Prepared by Michael Bench Consulting Arborist 2014 Species Group DBH Area 1 Trunk 2 Area2 Trunk 3 Area 3 In. Sq. Replace In. Sq. Price In. Sq. BASIC VALUE Species % Condition % Location % Un-rounded Value Rounded Value Cupressus macrocarpa 2 35 928 0 0 928.1 2.24 77.04 $71,676 50%50%70%$12,543 $12,500 Cupressus macrocarpa 2 20 314 0 0 314.0 2.24 77.04 $24,363 50%50%70%$4,264 $4,260 Ligustrum japonicum 3 7 38 6 28 5 20 62.4 3.80 45.46 $3,010 30%50%70%$316 $320 Quercus agrifolia 3 28 615 0 0 615.4 3.80 45.46 $28,151 90%70%70%$12,414 $12,400 Quercus agrifolia 3 9 64 0 0 63.6 3.80 45.46 $3,063 90%60%70%$1,158 $1,160 Quercus lobata 2 27 572 0 0 572.3 2.24 77.04 $44,260 90%60%70%$16,730 $16,700 Quercus lobata 2 32 788 0 0 787.6 2.24 77.04 $60,847 90%60%70%$23,000 $23,000 Quercus lobata 2 33 835 0 0 835.1 2.24 77.04 $64,508 90%60%70%$24,384 $24,400 Quercus lobata 2 26 531 15 177 0 619.0 2.24 77.04 $47,859 90%60%70%$18,091 $18,100 Umbellularia californica 2 7 38 0 0 38.5 2.24 77.04 $3,136 70%60%70%$922 $920 Quercus lobata 2 16 201 0 0 201.0 2.24 77.04 $15,655 90%70%70%$6,904 $6,900 Umbellularia californica 2 15 177 0 0 176.6 2.24 77.04 $13,780 70%40%70%$2,701 $2,700 Quercus lobata 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%60%70%$3,357 $3,360 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%60%70%$14,353 $14,400 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%60%70%$4,546 $4,550 Quercus agrifolia 3 21 346 0 0 346.2 3.80 45.46 $15,910 90%70%70%$7,016 $7,000 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%60%70%$5,209 $5,200 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%60%70%$13,233 $13,200 Quercus agrifolia 3 23 415 0 0 415.3 3.80 45.46 $19,051 90%70%70%$8,401 $8,400 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 3 26 531 0 0 530.7 3.80 45.46 $24,297 90%70%70%$10,715 $10,700 Quercus agrifolia 3 24 452 0 0 452.2 3.80 45.46 $20,728 90%70%70%$9,141 $9,100 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%70%70%$16,745 $16,700 Quercus lobata 2 17 227 0 0 226.9 2.24 77.04 $17,651 90%70%70%$7,784 $7,800 Quercus lobata 2 34 882 0 0 881.9 2.24 77.04 $68,118 90%30%70%$12,874 $12,900 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus agrifolia 3 11 95 0 0 95.0 3.80 45.46 $4,491 90%70%70%$1,980 $1,980 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%70%70%$6,077 $6,100 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%70%70%$1,036 $1,040 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%70%70%$1,783 $1,780 Quercus kelloggii 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%70%70%$5,304 $5,300 Pinus radiata 4 9 64 0 0 63.6 4.75 36.36 $2,485 30%50%70%$261 $260 Tree is gone Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus agrifolia 2 39 1106 0 0 1106.2 2.24 77.04 $85,392 90%50%70%$26,898 $26,900 Quercus agrifolia 2 7 38 0 0 38.5 2.24 77.04 $3,136 90%60%70%$1,185 $1,190 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%60%70%$1,528 $1,530 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%30%60%$1,008 $1,010 Quercus agrifolia 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%30%60%$1,439 $1,440 Aesculus califonica 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%60%60%$761 $760 Total =$338,140.00 TREE EVALUATION DATE 7-Dec-16 NAME Kevin Tsai ADDRESS 20972 Saratoga Hills, Saratoga CA 95070 PROTECTED TREE NO.SPECIES DIAMETER WIDTH/HEIGHTHEALTH STRUCTURE STATUS (X) **NOTES 1 Monterey Cypress 35 24/30 F F X Poorly topped and pruned from power lines 2 Monterey Cypress 20 14/25 F F X Poorly topped and pruned from power lines 3 Privet 5,6,7 15/20 F F X 4 Coast Live Oak 28 36/40 FG F X Boring insects, leaning, Rec spray program, EWR, RCE 5 Coast Live Oak 9 10/30 F F X Hollow at base from old tear, growing thru canopy of tree 6, Rec REMOVAL 6 Valley Oak 27 36/60 F FP X Large deadwood, Poorly attached codominant leaders at 8' ,Rec 1 cable, DWR, RCE, 7 Valley Oak 32 32/60 F FP X Large deadwood, poorly attached leader, Rec EWR, 1 cable, RCE 8 Valley Oak 33 50/60 F FP X Poorly attached codominant leaders at 10 ', one leader leaning over house, rec 1 cable, EWR, RCE 9 Valley Oak 15,26 50/60 F F X 10 Bay 7 15/35 FG F Bays can carry SOD, Canopy is within 15' of Coast Live Oak #4, Rec REMOVAL per California Oak Mortality Task Fore rcs: http://www.suddenoakdeath.org/wp-content/uploads/2010/08/arborist-6-10.pdf 11 Valley Oak 16 30/40 FP F X Leaning, large dead wood, Rec EWR 12 Bay 15 15/30 FG F X Leaning, large dead wood, adjoined at base with oak #12, growing into canopies of adjacent oak, REC REMOVAL 13 Valley Oak 12 40/25 F FP X Leaning severely, Rec prop if tree is valued, RCE on side away from creek 14 Valley Oak 25 30/60 F F X Leaning, large deadwood, Rec DWR 15 Valley Oak 18 40/60 FP FP X Leaning, rec EWR in direction of lean, RCE, Removal of Construction debris at base to relieve pressure on root zone 16 Valley Oak 14 30/35 F FP X Leaning, rec EWR in direction of lean, RCE 17 Coast Live Oak 21 30/55 FG FP X Leaning over creek, Rec EWR on creek side. 18 Valley Oak 15 30/50 F FP X Leaning, large deadwood, Rec EWR, DWR, RCE 19 Valley Oak 24 42/75 F FP X Leaning towards home, large hollow at base where limb was removed, poorly attached leaders at 35', Rec 1cable, EWR over home REC HAZARD ASSESSMENT to deteermine if REMOVAL is warranted. 20 Coast Live Oak 23 45/55 FG FP X Very heavy limb propped on another tree, tree Leaning towards pool and over stairway, poorly attached leaders at 8', REC severe EWR, or some EWR and specialized prop. 21 Valley Oak 10 20/40 F F X 22 Valley Oak 11 16/35 F F X Superficial hollow at base 23 Valley Oak 18 25/45 F F X 24 Valley Oak 10 25/25 FG FP X Leaning strongly, Rec EWR 25 Coast Live Oak 26 40/40 FG FP X Leaning strongly , Rec prop, EWR 26 Coast Live Oak 24 36/50 FG FP X Leaning towards stairway, propping tree #20, substantial rot in leader going towards pool, Rec, remove tree #20 from this tree, EWR on leader nearest pool 27 Valley Oak 25 30/50 FG FP X Large deadwood, leaning towards home, rec DWR, RCE, EWR 28 Valley Oak 17 35/40 FG FP X Leaning strongly over patio, growing into adjacent tree canopies, Rec prop, EWR, RCE, or REMOVAL 29 Valley Oak 34 45/70 P P X Dead, suspect ORF, Rec REMOVAL 30 Valley Oak 19 20/35 FG F X Many dead branches, Broken top, Rec RCE, DWR 31 Valley Oak 19 34/30 FG FP X Leaning strongly, Rec prop, EWR, RCE 32 Coast Live Oak 11 16/30 FG F X REC RCE 33 Valley Oak 15 25/35 FG F X 34 Coast Live Oak 10 12/20 FG F X 35 Coast Live Oak 6 12/20 FG F X 36 Coast Live Oak 8 14/25 FG F X Leaning, rec EWR on lean side, develpment of balancing leader from shoots opposite lean. 37 Black oak 14 18/35 FG FP X Multiple poorly attached leaders, Rec SP, 38 Monterey Pine 9 12/35 F FP This tree has died since our 2014 visit and was removed. 39 Valley Oak 24 60/60 G FP X Codominant Leaders 40 Valley Oak 24 50/60 G FP X Codominant Leaders 41 Coast Live Oak 39 60/70 FP FP X Codominant Leaders & thin canopy 42 Coast Live Oak 7 20/15 G FG X 43 Valley Oak 11 20/20 F FP X Codominant Leaders 44 Coast Live Oak 8 20/15 F FP X Leans 45 Coast Live Oak 7,7,10 20/20 F FP X Codominant Leaders 46 Coast Live Oak 10 20/15 F P X Topped 47 Coast Live Oak 12 20/15 F P X Topped 48 Buckeye 5,6 15/15 F FP X Codominant Leader Protected Trees =46 ** Applicable Local Tree Regulations: The Saratoga MunicIpal Code defines a protected tree as 1) any native tree with a DBH of 6" or greater including: Big Leaf Maple, CA Buckeye, Douglas Fir, Black Oak, Blue Oak, Coast Live Oak, Valley Oak, Tan Oak Scrub Oak Coast Redwood 2) All other species with a DBH of 10" or greater Based on these regulations 46 trees are protected. EWR - End Weight Reduction: pruning to remove weight from limb ends, thus reducing the potential for limb failure RCE - Root Collar Excavation: excavating a small area around a tree that is currently buried by soil or refuse above buttress roots, usually done with a hand shovel. SP - Structural pruning - removal of selected non-dominant leaders in order to balance the tree RATINGS KEY health structure good excellent/vigorous flawless fair/good healthy very stable fair fair routine maintenance needed fair/poor declining mitigation needed poor dead or near dead hazard Common Name Latin Name Bay Laurus nobilis Black Oak Quercus velutina Coast Live Oak Quercus Agrifolia Monterey Cypress Hesperocyparis macrocarpa Monterey Pine Pinus radiata Privet Ligustrum sp. Valley Oak Quercus lobata Buckeye Aesculus californica Site Tree Value Assessment California Prepared by Michael Bench Consulting Arborist 2014 Species Group DBH Area 1 Trunk 2 Area2 Trunk 3 Area 3 In. Sq. Replace In. Sq. Price In. Sq. BASIC VALUE Species % Condition % Location % Un-rounded Value Rounded Value Cupressus macrocarpa 2 35 928 0 0 928.1 2.24 77.04 $71,676 50%50%70%$12,543 $12,500 Cupressus macrocarpa 2 20 314 0 0 314.0 2.24 77.04 $24,363 50%50%70%$4,264 $4,260 Ligustrum japonicum 3 7 38 6 28 5 20 62.4 3.80 45.46 $3,010 30%50%70%$316 $320 Quercus agrifolia 3 28 615 0 0 615.4 3.80 45.46 $28,151 90%70%70%$12,414 $12,400 Quercus agrifolia 3 9 64 0 0 63.6 3.80 45.46 $3,063 90%60%70%$1,158 $1,160 Quercus lobata 2 27 572 0 0 572.3 2.24 77.04 $44,260 90%60%70%$16,730 $16,700 Quercus lobata 2 32 788 0 0 787.6 2.24 77.04 $60,847 90%60%70%$23,000 $23,000 Quercus lobata 2 33 835 0 0 835.1 2.24 77.04 $64,508 90%60%70%$24,384 $24,400 Quercus lobata 2 26 531 15 177 0 619.0 2.24 77.04 $47,859 90%60%70%$18,091 $18,100 Umbellularia californica 2 7 38 0 0 38.5 2.24 77.04 $3,136 70%60%70%$922 $920 Quercus lobata 2 16 201 0 0 201.0 2.24 77.04 $15,655 90%70%70%$6,904 $6,900 Umbellularia californica 2 15 177 0 0 176.6 2.24 77.04 $13,780 70%40%70%$2,701 $2,700 Quercus lobata 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%60%70%$3,357 $3,360 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%60%70%$14,353 $14,400 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%60%70%$4,546 $4,550 Quercus agrifolia 3 21 346 0 0 346.2 3.80 45.46 $15,910 90%70%70%$7,016 $7,000 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%60%70%$5,209 $5,200 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%60%70%$13,233 $13,200 Quercus agrifolia 3 23 415 0 0 415.3 3.80 45.46 $19,051 90%70%70%$8,401 $8,400 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 3 26 531 0 0 530.7 3.80 45.46 $24,297 90%70%70%$10,715 $10,700 Quercus agrifolia 3 24 452 0 0 452.2 3.80 45.46 $20,728 90%70%70%$9,141 $9,100 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%70%70%$16,745 $16,700 Quercus lobata 2 17 227 0 0 226.9 2.24 77.04 $17,651 90%70%70%$7,784 $7,800 Quercus lobata 2 34 882 0 0 881.9 2.24 77.04 $68,118 90%30%70%$12,874 $12,900 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus agrifolia 3 11 95 0 0 95.0 3.80 45.46 $4,491 90%70%70%$1,980 $1,980 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%70%70%$6,077 $6,100 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%70%70%$1,036 $1,040 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%70%70%$1,783 $1,780 Quercus kelloggii 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%70%70%$5,304 $5,300 Pinus radiata 4 9 64 0 0 63.6 4.75 36.36 $2,485 30%50%70%$261 $260 Tree is gone Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus agrifolia 2 39 1106 0 0 1106.2 2.24 77.04 $85,392 90%50%70%$26,898 $26,900 Quercus agrifolia 2 7 38 0 0 38.5 2.24 77.04 $3,136 90%60%70%$1,185 $1,190 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%60%70%$1,528 $1,530 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%30%60%$1,008 $1,010 Quercus agrifolia 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%30%60%$1,439 $1,440 Aesculus califonica 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%60%60%$761 $760 Total =$338,140.00 Site Tree Value Assessment California Prepared by Michael Bench Consulting Arborist 2014 Species Group DBH Area 1 Trunk 2 Area2 Trunk 3 Area 3 In. Sq. Replace In. Sq. Price In. Sq. BASIC VALUE Species % Condition % Location % Un-rounded Value Rounded Value Cupressus macrocarpa 2 35 928 0 0 928.1 2.24 77.04 $71,676 50%50%70%$12,543 $12,500 Cupressus macrocarpa 2 20 314 0 0 314.0 2.24 77.04 $24,363 50%50%70%$4,264 $4,260 Ligustrum japonicum 3 7 38 6 28 5 20 62.4 3.80 45.46 $3,010 30%50%70%$316 $320 Quercus agrifolia 3 28 615 0 0 615.4 3.80 45.46 $28,151 90%70%70%$12,414 $12,400 Quercus agrifolia 3 9 64 0 0 63.6 3.80 45.46 $3,063 90%60%70%$1,158 $1,160 Quercus lobata 2 27 572 0 0 572.3 2.24 77.04 $44,260 90%60%70%$16,730 $16,700 Quercus lobata 2 32 788 0 0 787.6 2.24 77.04 $60,847 90%60%70%$23,000 $23,000 Quercus lobata 2 33 835 0 0 835.1 2.24 77.04 $64,508 90%60%70%$24,384 $24,400 Quercus lobata 2 26 531 15 177 0 619.0 2.24 77.04 $47,859 90%60%70%$18,091 $18,100 Umbellularia californica 2 7 38 0 0 38.5 2.24 77.04 $3,136 70%60%70%$922 $920 Quercus lobata 2 16 201 0 0 201.0 2.24 77.04 $15,655 90%70%70%$6,904 $6,900 Umbellularia californica 2 15 177 0 0 176.6 2.24 77.04 $13,780 70%40%70%$2,701 $2,700 Quercus lobata 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%60%70%$3,357 $3,360 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%60%70%$14,353 $14,400 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%60%70%$4,546 $4,550 Quercus agrifolia 3 21 346 0 0 346.2 3.80 45.46 $15,910 90%70%70%$7,016 $7,000 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%60%70%$5,209 $5,200 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%60%70%$13,233 $13,200 Quercus agrifolia 3 23 415 0 0 415.3 3.80 45.46 $19,051 90%70%70%$8,401 $8,400 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus lobata 2 18 254 0 0 254.3 2.24 77.04 $19,767 90%60%70%$7,472 $7,500 Quercus lobata 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 3 26 531 0 0 530.7 3.80 45.46 $24,297 90%70%70%$10,715 $10,700 Quercus agrifolia 3 24 452 0 0 452.2 3.80 45.46 $20,728 90%70%70%$9,141 $9,100 Quercus lobata 2 25 491 0 0 490.6 2.24 77.04 $37,971 90%70%70%$16,745 $16,700 Quercus lobata 2 17 227 0 0 226.9 2.24 77.04 $17,651 90%70%70%$7,784 $7,800 Quercus lobata 2 34 882 0 0 881.9 2.24 77.04 $68,118 90%30%70%$12,874 $12,900 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus lobata 2 19 283 0 0 283.4 2.24 77.04 $22,005 90%70%70%$9,704 $9,700 Quercus agrifolia 3 11 95 0 0 95.0 3.80 45.46 $4,491 90%70%70%$1,980 $1,980 Quercus lobata 2 15 177 0 0 176.6 2.24 77.04 $13,780 90%70%70%$6,077 $6,100 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%70%70%$2,743 $2,740 Quercus agrifolia 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%70%70%$1,036 $1,040 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%70%70%$1,783 $1,780 Quercus kelloggii 2 14 154 0 0 153.9 2.24 77.04 $12,026 90%70%70%$5,304 $5,300 Pinus radiata 4 9 64 0 0 63.6 4.75 36.36 $2,485 30%50%70%$261 $260 Tree is gone Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus lobata 2 24 452 0 0 452.2 2.24 77.04 $35,007 90%50%70%$11,027 $11,000 Quercus agrifolia 2 39 1106 0 0 1106.2 2.24 77.04 $85,392 90%50%70%$26,898 $26,900 Quercus agrifolia 2 7 38 0 0 38.5 2.24 77.04 $3,136 90%60%70%$1,185 $1,190 Quercus lobata 2 11 95 0 0 95.0 2.24 77.04 $7,491 90%60%70%$2,831 $2,830 Quercus agrifolia 2 8 50 0 0 50.2 2.24 77.04 $4,043 90%60%70%$1,528 $1,530 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%60%70%$2,351 $2,350 Quercus agrifolia 2 10 79 0 0 78.5 2.24 77.04 $6,221 90%30%60%$1,008 $1,010 Quercus agrifolia 2 12 113 0 0 113.0 2.24 77.04 $8,881 90%30%60%$1,439 $1,440 Aesculus califonica 2 6 28 0 0 28.3 2.24 77.04 $2,350 90%60%60%$761 $760 Total =$338,140.00 TREE EVALUATION DATE 7-Dec-16NAMEKevin TsaiADDRESS20972 Saratoga Hills, Saratoga CA 95070 PROTECTEDTREE NO.SPECIES DIAMETER WIDTH/HEIGHTHEALTH STRUCTURE STATUS (X) **NOTES1Monterey Cypress 35 24/30 F F X Poorly topped and pruned from power lines2Monterey Cypress 20 14/25 F F X Poorly topped and pruned from power lines3Privet5,6,7 15/20 F F X4Coast Live Oak 28 36/40 FG F X Boring insects, leaning, Rec spray program, EWR, RCE5Coast Live Oak 9 10/30 F F X Hollow at base from old tear, growing thru canopy of tree 6, Rec REMOVAL6Valley Oak 27 36/60 F FP X Large deadwood, Poorly attached codominant leaders at 8' ,Rec 1 cable, DWR, RCE,7 Valley Oak 32 32/60 F FP X Large deadwood, poorly attached leader, Rec EWR, 1 cable, RCE8Valley Oak 33 50/60 F FP X Poorly attached codominant leaders at 10 ', one leader leaning over house, rec 1 cable, EWR, RCE9Valley Oak 15,26 50/60 F F X10Bay715/35 FG F Bays can carry SOD, Canopy is within 15' of Coast Live Oak #4, Rec REMOVAL per California Oak Mortality Task Fore rcs: http://www.suddenoakdeath.org/wp-content/uploads/2010/08/arborist-6-10.pdf11Valley Oak 16 30/40 FP F X Leaning, large dead wood, Rec EWR12Bay1515/30 FG F X Leaning, large dead wood, adjoined at base with oak #12, growing into canopies of adjacent oak, REC REMOVAL13Valley Oak 12 40/25 F FP X Leaning severely, Rec prop if tree is valued, RCE on side away from creek14Valley Oak 25 30/60 F F X Leaning, large deadwood, Rec DWR15Valley Oak 18 40/60 FP FP X Leaning, rec EWR in direction of lean, RCE, Removal of Construction debris at base to relieve pressure on root zone16Valley Oak 14 30/35 F FP X Leaning, rec EWR in direction of lean, RCE17Coast Live Oak 21 30/55 FG FP X Leaning over creek, Rec EWR on creek side.18 Valley Oak 15 30/50 F FP X Leaning, large deadwood, Rec EWR, DWR, RCE19Valley Oak 24 42/75 F FP X Leaning towards home, large hollow at base where limb was removed, poorly attached leaders at 35', Rec 1cable, EWR over home REC HAZARD ASSESSMENT to deteermine if REMOVAL is warranted. 20 Coast Live Oak 23 45/55 FG FP X Very heavy limb propped on another tree, tree Leaning towards pool and over stairway, poorly attached leaders at 8', REC severe EWR, or some EWR and specialized prop. 21 Valley Oak 10 20/40 F F X 22 Valley Oak 11 16/35 F F X Superficial hollow at base 23 Valley Oak 18 25/45 F F X 24 Valley Oak 10 25/25 FG FP X Leaning strongly, Rec EWR 25 Coast Live Oak 26 40/40 FG FP X Leaning strongly , Rec prop, EWR 26 Coast Live Oak 24 36/50 FG FP X Leaning towards stairway, propping tree #20, substantial rot in leader going towards pool, Rec, remove tree #20 from this tree, EWR on leader nearest pool 27 Valley Oak 25 30/50 FG FP X Large deadwood, leaning towards home, rec DWR, RCE, EWR 28 Valley Oak 17 35/40 FG FP X Leaning strongly over patio, growing into adjacent tree canopies, Rec prop, EWR, RCE, or REMOVAL 29 Valley Oak 34 45/70 P P X Dead, suspect ORF, Rec REMOVAL 30 Valley Oak 19 20/35 FG F X Many dead branches, Broken top, Rec RCE, DWR 31 Valley Oak 19 34/30 FG FP X Leaning strongly, Rec prop, EWR, RCE 32 Coast Live Oak 11 16/30 FG F X REC RCE 33 Valley Oak 15 25/35 FG F X 34 Coast Live Oak 10 12/20 FG F X 35 Coast Live Oak 6 12/20 FG F X 36 Coast Live Oak 8 14/25 FG F X Leaning, rec EWR on lean side, develpment of balancing leader from shoots opposite lean. 37 Black oak 14 18/35 FG FP X Multiple poorly attached leaders, Rec SP, 38 Monterey Pine 9 12/35 F FP This tree has died since our 2014 visit and was removed. 39 Valley Oak 24 60/60 G FP X Codominant Leaders 40 Valley Oak 24 50/60 G FP X Codominant Leaders 41 Coast Live Oak 39 60/70 FP FP X Codominant Leaders & thin canopy 42 Coast Live Oak 7 20/15 G FG X 43 Valley Oak 11 20/20 F FP X Codominant Leaders 44 Coast Live Oak 8 20/15 F FP X Leans 45 Coast Live Oak 7,7,10 20/20 F FP X Codominant Leaders 46 Coast Live Oak 10 20/15 F P X Topped 47 Coast Live Oak 12 20/15 F P X Topped 48 Buckeye 5,6 15/15 F FP X Codominant Leader Protected Trees =46 ** Applicable Local Tree Regulations: The Saratoga MunicIpal Code defines a protected tree as 1) any native tree with a DBH of 6" or greater including: Big Leaf Maple, CA Buckeye, Douglas Fir, Black Oak, Blue Oak, Coast Live Oak, Valley Oak, Tan Oak Scrub Oak Coast Redwood 2) All other species with a DBH of 10" or greater Based on these regulations 46 trees are protected. EWR - End Weight Reduction: pruning to remove weight from limb ends, thus reducing the potential for limb failure RCE - Root Collar Excavation: excavating a small area around a tree that is currently buried by soil or refuse above buttress roots, usually done with a hand shovel. SP - Structural pruning - removal of selected non-dominant leaders in order to balance the tree RATINGS KEY health structure good excellent/vigorous flawless fair/good healthy very stable fair fair routine maintenance needed fair/poor declining mitigation needed poor dead or near dead hazard Common Name Latin Name Bay Laurus nobilis Black Oak Quercus velutina Coast Live Oak Quercus Agrifolia Monterey Cypress Hesperocyparis macrocarpa Monterey Pine Pinus radiata Privet Ligustrum sp. Valley Oak Quercus lobata Buckeye Aesculus californica FA1.3(E) 23" OAK (E) 21" OAK (E) 24" OAK (E)10" OAK(E) 7" OAK (E) 26" OAK (E) 6" B-EYE (E) 8" B-EYE (E) 8" ACACIA GROUP (E)11" OAK (E)12" OAK (E)14" OAK (E)16" OAK (E)12" OAK(E)12" OAK (E)11" OAKS (E) BRIDGE (E ) S W A L E S 67°41'00" E 170. 5 4 '578#40 #41 #42 #43 #44 #45 #46 #47 #48 N 4 4 ° 5 2 ' 0 0 " W 11 0 . 9 2 ' S 67°41'00" E 170. 5 4 ' SEE TREE PROTECTION FENCE DETAILMATCH LINESEE A1.1(E) SWIMMING POOL TO BE REMOVED (SHOWN DOTTED) PROVIDE TREE PROTECTION FENCING PROPOSED FENCE, TYP. REMOVE BY HAND (E) POOL EQUIP. ENCLOSURE REMOVE (E) CONC. PAD LINE ± (E) DRIP (E) DRIPLINE ± 15 4 5 4 15 15 1 A1.0 PRO P ER TY L I N E PR O P E R T Y L I N E (N) PARTIAL SITE PLAN SCALE: 1" = 10' 72 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A1.2 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects620.00' 616.00' 612.00' 608.00' 604.00' 600.00' 596.00' 624.00' 618.00' 614.00' 610.00' 606.00' 602.00' 598.00' 622.00' 611.00' 607.00' 603.00' 599.00' 591.00' 587.00' 615.00' 609.00' 605.00' 601.00' 597.00' 593.00' 589.00' 613.00' 25'-0" F.F.≈595.20'8'-0"±8'-6"12'-0"±11'-3"±8'-1"NEW DRIVEWAY F.F.≈604.49'4'-6"26'-0"NEW ADDITION EXISTING TO REMAIN 5'-0"T.O. <E> SUBFLR. @ MAIN FLR. T.O. <E> SUBFLR. @ MAIN FLR. AVG. (E) GRADE (N) MASTER BDRM.(N) VESTIBULE(N) M. BATH(E) LIVING RM.(E) BEDRM. #3 (E) VESTIBULE (E) BATH #3 (N) GARAGE(N) MUD RM.(E) CELLAR STORAGE 26'-0" MAX. HEIGHT T.O. <E> PLATE @ BEDRM. #3 T.O. <N> PLATE @ M. BEDROOM T.O. <N> SUBFLR. @ MUD RM. 595.00' 617.87' 604.43' 612.51' 604.43' 616.51'12'-1"±8'-7"603.72' 595.14' 598.24' 624.24' EXTERIOR SIDE SETBACK 30'-0" FRONT SETBACK APEX OF ROOF EXISTING GRADE FINISH GRADE NEW DRIVEWAY FINISH GRADE EXISTING GRADE EXISTING ROOF LINE TO REMAIN 50'-0" R.O.W. T.O. <E> PLATE @ LOWER FLR. NEW CONC. RETAINING WALL 5'-0" TALL MAX EXISTING WALL LINE @ MAIN FLOOR EXISTING CHIMNEY OUTLINE TO BE REMOVED NEW ADDITION REMODEL (E) FAMILY MAX.620.00' 616.00' 612.00' 608.00' 604.00' 600.00' 596.00' 624.00' 618.00' 614.00' 610.00' 606.00' 602.00' 598.00' 622.00' 611.00' 607.00' 603.00' 599.00' 591.00' 587.00' 615.00' 609.00' 605.00' 601.00' 597.00' 593.00' 589.00' 613.00' 25'-0"±8'-1"NEW DRIVEWAY F.F.≈604.49'8'-0"±8'-0"10'-0"26'-0"5'-0"5'-0"3'-5"EXISTING TO T.O. <E> SUBFLR. @ MAIN FLR. T.O. <E> SUBFLR. @ MAIN FLR. AVG. (E) GRADE T.O. <E> PLATE @ BATH #2 T.O. <N> PLATE @ NOOK 26'-0" MAX. HEIGHT (N) NOOK(E) BATH #2 (N) FOYER(N) DINING RM.(E) BEDRM. #2 CLOSET 595.00' 604.43' 612.51' 604.43' 612.51'8'-1"598.24' 624.24' EXTERIOR SIDE SETBACK 30'-0" FRONT SETBACK 50'-0" R.O.W. EXISTING GRADE NEW DRIVEWAY FINISH GRADE EXISTING GRADE NEW RETAINING WALL REMOVE EXISTING WALL LINE REMOVE EXISTING ROOF LINE MAX.MAX.NEW ADDITION REMAIN 620.00' 616.00' 612.00' 608.00' 604.00' 600.00' 596.00' 624.00' 618.00' 614.00' 610.00' 606.00' 602.00' 598.00' 622.00' 611.00' 607.00' 603.00' 599.00' 591.00' 587.00' 615.00' 609.00' 605.00' 601.00' 597.00' 593.00' 589.00' 613.00' 25'-0"±8'-1"NEW DRIVEWAY F.F.≈604.49'F.F.≈604.49'±8'-0"12'-0"26'-0"NEW ADDITIONEXISTING TO 4'-4"1'-6"2'-9"T.O. <E> SUBFLR. @ MAIN FLR. T.O. <E> SUBFLR. @ MAIN FLR. AVG. (E) GRADE 26'-0" MAX. HEIGHT (N) KITCHEN(E) BEDRM. #2 T.O. <E> PLATE @ BEDRM. #2 T.O. <N> PLATE @ KITCHEN (N) DECK 595.00' 604.43' 612.51' 604.43' 616.51'12'-1"598.24' 624.24' EXTERIOR SIDE SETBACK 30'-0" FRONT SETBACK 50'-0" R.O.W. EXISTING GRADE FINISH GRADE EXISTING GRADE NEW RETAINING WALL NEW RETAINING WALL REMOVE EXISTING WALL LINE REMOVE EXISTING ROOF LINE REMAIN MAX.NEW DRIVEWAY FINISH GRADE 0 4'8'16' 0 4'8'16' 0 4'8'16' SITE SECTION "A" SCALE: 1/8" = 1'-0" SITE SECTION "B" SCALE: 1/8" = 1'-0" SITE SECTION "C" SCALE: 1/8" = 1'-0" 73 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A1.3 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects620.00' 616.00' 612.00' 608.00' 604.00' 600.00' 596.00' 624.00' 618.00' 614.00' 610.00' 606.00' 602.00' 598.00' 622.00' 611.00' 607.00' 603.00' 599.00' 591.00' 587.00' 615.00' 609.00' 605.00' 601.00' 597.00' 593.00' 589.00' 613.00'12'-0"±8'-9"12'-0"12'-1"F.F.≈595.20' F.F.≈604.49' NEW ADDITION 26'-0"T.O. <N> SUBFLR. @ MAIN FLR. T.O. <E> SUBFLR. @ MAIN FLR. AVG. (E) GRADE NEW DRIVEWAY M. BATH (E) LAUNDRY (E) BEDRM. #4MUD RM. STAIR WELLKITCHEN (E) DECK T.O. <N> PLATE @ M. BATH T.O. <E> SUBFLR. @ BEDRM. #4 T.O. <N> PLATE @ KITCHEN 26'-0" MAX. HEIGHT REMOVE EXISTING ROOF LINE EXISTING TO REMAIN & PARKING AREA 595.00'12'-1"±8'-9"604.43' 616.51' 617.87' 604.43' 616.51' 603.68' 594.93' 598.24' 624.24' T.O. <E> PLATE @ LOWER FLR. 20'-0" INTERIOR SIDE SETBACK EXISTING GRADE FINISH GRADE EXISTING GRADE APEX OF ROOF REMOVE EXISTING WALL LINE EXISTING CHIMNEY OUTLINE TO BE REMOVED 624.00' 620.00' 616.00' 612.00' 608.00' 604.00' 600.00' 628.00' 622.00' 618.00' 614.00' 610.00' 606.00' 602.00' 626.00' 611.00' 607.00' 603.00' 599.00' 591.00' 587.00' 615.00' 609.00' 605.00' 601.00' 597.00' 593.00' 589.00' 613.00'12'-1"F.F.≈595.44' F.F.≈604.49'12'-0"±8'-6"NEW ADDITION EXISTING TO REMAIN 26'-0"T.O. <N> SUBFLR. @ MAIN FLR. T.O. <E> SUBFLR. @ MAIN FLR. AVG. (E) GRADE NEW DRIVEWAY T.O. <E> PLATE @ LIVING RM. T.O. <E> SUBFLR. @ BEDRM. #4 T.O. <N> PLATE @ FOYER 26'-0" MAX. HEIGHT (E) LIVING RM. (E) BEDRM. #5 (N) FOYER (E) STOR.(E) CELLAR STORAGE REMOVE EXISTING ROOF LINE & PARKING AREA 595.00'±8'-1"±8'-9"604.43' 616.51' 617.87' 604.43' 612.51' 603.68' 594.93' 598.24' 624.24' T.O. <E> PLATE @ LOWER FLR. 20'-0" INTERIOR SIDE SETBACK APEX OF ROOF EXISTING GRADE FINISH GRADE EXISTING GRADE REMOVE EXISTING WALL LINE EXISTING CHIMNEY OUTLINE TO BE REMOVED 624.00' 620.00' 616.00' 612.00' 608.00' 604.00' 600.00' 628.00' 622.00' 618.00' 614.00' 610.00' 606.00' 602.00' 626.00' 611.00' 607.00' 603.00' 599.00' 591.00' 587.00' 615.00' 609.00' 605.00' 601.00' 597.00' 593.00' 589.00' 613.00'8'-9"±8'-0"F.F.≈604.49'±8'-1"NEW 26'-0"T.O. <N> SUBFLR. @ MAIN FLR. T.O. <E> SUBFLR. @ MAIN FLR. AVG. (E) GRADE BATH #3BEDRM. #2 M. CLOSET (N) OFFICE 26'-0" MAX. HEIGHT NEW DRIVEWAY T.O. <N> PLATE @ OFFICE T.O. <E> SUBFLR. @ BEDRM. #4 T.O. <E> PLATE @ BEDRM. #2 EXISTING TO REMAIN ADDITION 595.00' 617.87'8'-10"±8'-9"604.43' 612.51' 604.43' 613.26' 603.68' 594.93' 598.24' 624.24' 20'-0" INTERIOR SIDE SETBACK APEX OF ROOF EXISTING GRADE FINISH GRADE EXISTING GRADE T.O. <E> PLATE @ LOWER FLR. EXISTING ROOF LINE EXISTING CHIMNEY OUTLINE TO BE REMOVED 0 4'8'16' 0 4'8'16' 0 4'8'16' SITE SECTION "D" SCALE: 1/8" = 1'-0" SITE SECTION "E" SCALE: 1/8" = 1'-0" SITE SECTION "F" SCALE: 1/8" = 1'-0" 74 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A3.0 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' 598 602 (R) (E) 6" ORNAM.594592590588586584582604 602 600 598 596 (E) 35" OAK (E) 26" OAK (E)11" OAK (E)13" OAK (E) 25" OAK (E)12" OAK 25'-0" EXTERIOR SIDE SETBACKSLOPE ¼" PER FT. <E> W.C. <E> W.C. <E> TUB <N> TUB <E> 40x24F.P. w/ 8" TALLHEARTH<E> SINK <E> SINK *TEMP*DN15R@ ±7½" EA.<N>D.W.<N> 30" FRZR. <N> 30" REFR.*TEMP.**TEMP.**TEMP.*DN16R @ ±7¼" EA.±23'-6"±43'-0"16'-0"±19'-9"9'-0" ±60'-11" 12'-0"5'-10"16'-1"38'-0"9'-0" ±80'-11"10'-0"9'-6"9'-6"±22'-8" A A1.2 A A1.2 B A1.2 B A1.2 C A1.2 C A1.2 D A1.3 D A1.3 E A1.3 E A1.3 F A1.3 F A1.3 <N> SINK <N> W.C. <N> SINK <N>W.C.<N>SINK<N>SINKPANTRY <N> SINK BENCHLINEN <E> CABINETRY <E> 29x68 C.O. BATH #2 <E> 80 FLAT CLG. <E> TILE M. CLOS. <E> 80 FLAT CLG. <E> HARDWD. FLR'G. B.R. HALL <E> 80 FLAT CLG. <E> HARDWD. FLR'G.<E> PR. 28x68 SLID'G. DRS. <E> PR. 28x68 SLID'G. DRS. BATH #3 <E> 80 FLAT CLG. <E> TILE HALL <E> 80 FLAT CLG. <N> HARDWD. FLR'G. DECK F.F.≈604.20' VESTIBULE <E> 80 FLAT CLG. <N> HARDWD. FLR'G. GALLERY <N> 80 FLAT CLG. <N> HARDWD. FLR'G. NOOK <N> 80 FLAT CLG. <N> HARDWD. FLR'G. POWDER <N> 80 FLAT CLG. <N> TILE VESTIBULE <N> 80 FLAT CLG. <N> HARDWD. FLR'G. CANTILEVERED DECK F.F.≈604.40' <N> TILE <N>120 FLAT CLG. M. BATH M. CLOSET <N> 80 FLAT CLG. <N> FLR'G. <N> 80 FLAT CLG. <N> 80 FLAT CLG.<N> 80 FLAT CLG.<E> PR.30X68FR. DRS.BDRM. #2 <E> 80 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈604.49'<E>28X68DR.<E>28X68DR.<E>24X68DR.<E>24X68DR.BEDROOM #3 <E> 80 FLAT CLG. <E> HARDWD. FLR'G. <N> 26X40 CSMNT. @68 HDR. <N> 26X40 CSMNT. @68 HDR.<E>30X22CSMNT.@68 HDR.<E>16X22CSMNT.@68 HDR.<E>16X22CSMNT.@68 HDR.<E>28X68DR.<E >28X68DR.<E> PR.20X32CSMNTS.@68 HDR.<E> DR.<N> PR.30X40CSMNTS.@68 HDR.LIVING ROOM <E> VLT'D. CLG. w/ BEAMS <E> HARDWD. FLR'G.<E>28x68FR. DR.<E> 20x40 SKYLTS. DINING ROOM <N>100 FLAT CLG. <N> HARDWD. FLR'G. <E> 3x6 <E> 4x12<N> 28X68 DR. FOYER <N>120 FLAT CLG. <N> HARDWD. FLR'G. F.F.≈604.49' KITCHEN <N>120 FLAT CLG. <N> HARDWD. FLR'G. OFFICE <N> 89 FLAT CLG. <N> HARDWD. FLR'G.50x80PIVOT DR.w/32 TRANS.ABV.MASTER BEDRM. <N>120 FLAT CLG. <N> FLR'G. <N> 28X68 DR. <N> 28X68 DR.<N>28X68DR.<N> 28X56 CSMNT. @80 HDR. w/32 AWN'G. ABV. <N> 28X56 CSMNT. @80 HDR. w/32 AWN'G. ABV. <N> 28X56 FIXED @80 HDR. w/32 TRANS. ABV. <N> 28X56 FIXED @80 HDR. w/32 TRANS. ABV.<N>28X56CSMNT.@80 HDR.w/32AWN'G.ABV.<N>28X56FIXED@80 HDR.w/32TRANS.ABV.<N>28X56CSMNT.@80 HDR.w/32AWN'G.ABV.<N>36X68C.O.<N>28X36AWN'G.@80 HDR.<N>28X36AWN'G.@80 HDR.<N> 28X36 AWN'G. @80 HDR. <N> 28X36 AWN'G. @80 HDR.<N>40X56FIXED@80 HDR.w/26 AWN'G.BELOW*TEMP.*<N>40X56FIXED@80 HDR.w/26 AWN'G.BELOW*TEMP.*<N>28X46CSMNT.@80 HDR.w/32AWN'G.ABV.<N>28X46CSMNT.@80 HDR.w/32AWN'G.ABV.<N> 28X46 CSMNT. @80 HDR. w/32 TRANS. ABV. <N> 28X46 CSMNT. @80 HDR. w/32 TRANS. ABV. <N> 28X46 CSMNT. @80 HDR. w/32 TRANS. ABV. <N> 28X46 CSMNT. @80 HDR. w/32 TRANS. ABV. <N> 36X76 FIXED @100 HDR. w/26 AWN'G. BELOW <N> 36X76 FIXED @100 HDR. w/26 AWN'G. BELOW <N> 18X56 FIXED @80 HDR. w/26 FIXED BELOW & TRANS. ABV.<N>28X68DR.<N> 28X80 DR. <N> 146X68 C.O. <N> 26X60 CSMNT. @89 HDR. <N> 26X60 CSMNT. @89 HDR. <N> 26X60 FIXED @89 HDR. <N> 26X60 FIXED @89 HDR.<N>26X60CSMNT.@89 HDR.<N>26X60CSMNT.@89 HDR.<N> PR.26X68FR. DRS.*TEMP.*<N>26X60CSMNT.@89 HDR.NEW LOCATION OF GAS METER <E> ELEC. METER DN. ±1¾" DN. ±1¾" DN. 2R DN. ±4" <N> 80X80 2-PANEL SLID'G. GLS. DRS. *TEMP.* DN. ±1¾" DN. ±1" <N> OVEN/ M.W. <N> 36" RANGE & HOOD BENCH DN. ±1¾" DN. 2R @±5" EA. <N> 96x80 3-PANEL SLID'G. GLS. DRS. *TEMP.* w/32 TRANS. ABV. <N> 110x68 4-PANEL SLID'G. GLS. DRS. *TEMP.*<N>40x80BARN DR.FLAT T.V. 604.15' CONC. CONC. 603.65' EXISTING EXISTING (MATCH EXISTING)ADDITIONEXISTING (MATCH EXISTING) <R> GAS <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. HATCHED AREAS INDICATE EXISTING TO REMAIN - NO NEW WORK - EXTERIOR CAN LIGHTS- EXTERIOR CAN LIGHTS, TYP.- - <E> ATTIC ACCESS <E> ATTIC ACCESS <E> WALL HTR. <E> ATTIC ACCESS (N) MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" NEW WALL (2X STUDS @ 16" O.C.) TYPICAL, U.N.O. EXPOSED BEAM ABOVE TYPICAL, U.N.O. EXISTING WALL TO REMAIN, TYPICAL, U.N.O. D 4x4 D.F. POST W/ HTT22 (E) (N) HOLDOWN LOCATION, SEE HOLDOWN LEGEND FOR MORE INFORMATION TYPICAL, U.N.O. 1 NEW ITEMS TO BE INSTALLED AT LOCATIONS INDICATED, TYPICAL, U.N.O.26 DRDOOR DESIGNATION, TYP. U.N.O. DOOR SIZE DOOR TYPE (OPTIONAL) EXISTING ITEMS TO REMAIN, PROTECT FROM DAMAGE DURING CONSTRUCTION, TYPICAL, U.N.O. SHEARWALL DESIGNATION, SEE SHEARWALL SCHEDULE FOR MORE INFO. TYPICAL U.N.O. WINDOW SIZE (WIDTH/HEIGHT) WINDOW TYPE26x36 CSMNT CONSTRUCTION LEGEND <R>EXISTING ITEMS TO BE RELOCATED AT LOCATION INDICATED, TYPICAL, U.N.O. 75 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A3.1 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' 598 596 594 592 (R) (E) 6" ORNAM.594592590588586584582602 600 598 596 594 592 (E) 35" OAK (E) 24" OAK (E)13" OAK (E)14" OAK (E)12" OAK (E)11" OAK (E) 24" OAK (E) 25" OAK (E)12" OAK 25'-0" EXTERIOR SIDE SETBACK25'-0" EXTERIOR SIDE SETBACKSLOPE 1/4" PER FT. TO O.H. DR. <E> W.C. *TEMP *UP15R@ ±7½" EA.UP16R @ ±7¼" EA. A A1.2 A A1.2 D A1.3 D A1.3 E A1.3 E A1.3 F A1.3 F A1.3 <E>SINKBENCH CUB.CUB.<E>24 PKT.DR.LAUNDRY <E> ±83 FLAT CLG. w/ BEAMS <E> HARDWD. FLR'G. F.F.≈595.49'<E>29 C.O.STORAGE <E> ±80 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈595.74' BATH #4 <E> ±86 FLAT CLG. <E> TILE <E> W <E> D CELLAR/STORAGE <E> CONC. SLAB F.F.≈595.44'<E>80X762-PANELSLID'G.GLS. DRS.<E>80X762-PANELSLID'G.GLS. DRS.<E> 60X76 2-PANEL SLID'G. GLS. DRS. MUD ROOM <E> ±86 FLAT CLG. w/ BEAMS <N> TILE FLR'G. F.F.≈595.20' <N> ±88½ FLAT CLG. <N> CONC. F.F. ≈ 595.03' WORK SHOP (E) LOWER PATIO PROTECT EXISTING PAVING TO REMAIN <E> PR.28 DR.<E>28 DR.BEDROOM #5 <E> ±86 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈595.20' BEDROOM #4 <E> ±89 FLAT CLG. w/ BEAMS <E> STONE TILE F.F.≈594.99'<E>28 DR.<E>24 DR.<E>26 DR.<N> 30X53 CSMNT. @83 HDR. <N> 30X53 FIXED @83 HDR.<N>46X53FIXED@76 HDR.<E> 18X76 FIXED @76 HDR. <E> PR. 20X42 CSMNTS. @±70 HDR. <E> PR. 20X42 CSMNTS. @±70 HDR.<E>20X32CSMNT.NEW GARAGE <N> FLAT CEILING 5/8" ONE HR. GYP. <N> CONC. FLR'G. F.F.≈594.23' <E> 4x14 BEAM <E> 4x8 BEAMSNO WORK EXISTING TO REMAIN IN HATCHED AREAS 1,106 S.F.<N>28x68DR.<N>28x68S.C. DR.<N> ACC E S S PAN E L NEW LOCATION OF GAS METER UP ±6" UP ±2½" UP ±3" DN. ±1¼" <R> GAS DN. ±7" DN. ±3¾"DN.±3"DN.±3"DN. ±3" DN. 2" STORAGE STORAGE <N>160x80O.H. GAR. DR.(3" FUTURE) (0" FUTURE) DN ±2½" 594.00' SLAB @ DR. 594.46' SLAB DECKABOVE<N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. - HATCHED AREAS INDICATE EXISTING TO REMAIN - NO NEW WORK - <N> F.A.U. (N) LOWER FLOOR PLAN SCALE: 1/4" = 1'-0" NEW WALL (2X STUDS @ 16" O.C.) TYPICAL, U.N.O. EXPOSED BEAM ABOVE TYPICAL, U.N.O. EXISTING WALL TO REMAIN, TYPICAL, U.N.O. D 4x4 D.F. POST W/ HTT22 (E) (N) HOLDOWN LOCATION, SEE HOLDOWN LEGEND FOR MORE INFORMATION TYPICAL, U.N.O. 1 NEW ITEMS TO BE INSTALLED AT LOCATIONS INDICATED, TYPICAL, U.N.O.26 DRDOOR DESIGNATION, TYP. U.N.O. DOOR SIZE DOOR TYPE (OPTIONAL) EXISTING ITEMS TO REMAIN, PROTECT FROM DAMAGE DURING CONSTRUCTION, TYPICAL, U.N.O. SHEARWALL DESIGNATION, SEE SHEARWALL SCHEDULE FOR MORE INFO. TYPICAL U.N.O. WINDOW SIZE (WIDTH/HEIGHT) WINDOW TYPE26x36 CSMNT CONSTRUCTION LEGEND <R>EXISTING ITEMS TO BE RELOCATED AT LOCATION INDICATED, TYPICAL, U.N.O. WINDOW SCHEDULE NOTE TO GENERAL CONTRACTOR contractor to verify brand name, sizes, types, & rough openings of all windows, exterior doors, & skylights, & shall notify the architect of any discrepancies from or changes to the plans. architect and owner must review and approve all windows, exterior doors, & skylights prior to placing final window/door order. if window order is not reviewed and approved by the architect, the architect assumes absolutely no responsibility whatsoever for any mistakes, errors, or omissions! W 1. Windows see floor plan & exterior elevations for window sizes/types, typical, u.n.o. use dual insulating low e2 glass (argon filled) at all new windows, typical, u.n.o. provide multi-point locking system at all operable windows, typical, u.n.o. a . typical existing windows : Andersen Windows & Doors, or equiv., brown vinyl clad (verify exact color match prior to ordering) wood frame casement, sliding and fixed windows, w/pre-primed paint grade pine @ interior. provide multi-point locking system and aluminum frame insect screens at all operable windows, typical, u.n.o. b . option for all new windows: Kolbe “VistaLuxe Collection” or Loewen Windows & Doors, or equiv., aluminum clad (Gingersnap or Truffle- verify exact color prior to ordering) wood frame casement, awning and fixed windows, w/clear finished stain grade vertical grain douglas fir @ interior. provide fixed aluminum frame “Vivid View” insect screens at all operable windows, typical, u.n.o. b . verification: coordinate window sizes, jamb depths, hardware type/color, cladding color, screens, etc. with architect and owner prior to ordering windows and doors. W 2. Tempered Glass indicated on plan by "TEMP" provide tempered safety glass at all hazardous locations per sec. R3 08.4, 2013 CRC. W 3. Skylights see roof plan & exterior elevations for skylight sizes/types, typical, u.n.o. Velux (Uniform ES Evaluation Report #0199) flush, or curb mounted bronze anodized aluminum clad wood frame skylight w/ dual tempered argon filled “Comfort Plus” tinted glazing. install w/ flashing per the manuf. specs. typical, u.n.o. GREEN POINT R ATED NOTE The NFRC label which states the required U-value and SGHC for all fenestration products shall not be removed prior to inspection or removal by a building inspector, and shall reflect the values listed in the energy report. 76 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A5.0 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if roof & 2'-0" (min.) chimney clearance above all roofs within 10'-0" per sec. R 1003.9, 2013 CRC. Sydney Peak “Azul Blend” by GraniteRock required, contractor shall provide a copy of the manuf. U .L . Listing for any new chimney rain caps/shrouds, per sec. 2113A .9.1, 2013 CBC. typical, u.n.o. b . adhered stone veneer new thin stone veneer at chimney per exterior elevations per details. install all stone per manuf. specs – see note #5.d. above, typical, u.n.o. 13. Attic Exhaust Vents see details & cross sections for more info. a . existing attic vents existing eave & roof mounted vents to remain where occurs at existing attics to remain, typical, u.n.o. b . new attic ventilation: none required or provided at new roofs per sec. 806.4.5.1, 2013 CRC. use open cell spray polyurethane foam insulation at attic/roof. 14. Site Grading see site plan and Grading & Drainage plans by Jakaby Engineering for more info. a . existing grade to be cut and filled as shown on Grading & Drainage plan, typical u.n.o. b . finish grade to slope 5% min. away from base of building at soil and 2% min. at paving, per sec. R300.2, 2013 CRC in accordance w/ 2013 CGBSC, chapter 4, Division 4.1. typical, u.n.o. 15. New Exterior Trellises all lumber to be S4S clear cedar - see details for more info., typical, u.n.o. 1 ½” thick x 2” sq. bar spaces - GIA-200-2 aluminum I-Bar grating - as manuf. by McNichols over 6x cantilevered cedar trellis beams per details, typical, u.n.o. 16. Landscaping See landscape drawings by Johnna Brooks – Divine Nature Landscape Design, typical, u.n.o. 17. Retaining Walls and Landscape Walls see geotechnical report by Murray Engineers, Inc. & grading and drainage plan by Jakaby Engineering for more info. See landscape architect’s drawings, details, & cross sections for more details & specs, typical, u.n.o. a . board formed concrete retaining walls install new board formed poured in place colored concrete retaining walls where show. See structural engineering drawings and details for more info. typical, u.n.o. b . board formed concrete landscape walls 3’-0” max. height board formed concrete - see landscape drawings for more info, typical, u.n.o. c . french drains at all retaining walls 4” dia. perforated pipe at base of retaining walls. slope @ 1% min., connect to underground tight line & daylight at energy dissipaters as shown on grading plan. 18. Wood Decks/Stairs stoops at all exterior doors shall conform to sec. 1008.1.4 & sec. 1008.1.5, 2013 CBC. New 5/4 x 6 IPE decking, over 2x8 ACQ p.t .d .f . deck joists @ 16” o.c. with 6x8 ptdf girders per structural framing plans, typical, u.n.o. use stainless steel screws, verify attachment methods in field with Architect. 19. Rear Deck Guardrails see exterior elevations, and details for more info, typical. final design & shop drawings for exterior guardrail design to be handled as a deferred submittal by the Contractor & submitted to Bldg. Dept., owner, & architect for approval prior to fabrication, typical, u.n.o. guardrail system shall conform to 2012 IRC, sec. R 312, and sec. 1013 & sec. 1607A .7, 2013 CBC: for 200 lb. concentrated loading applied in any direction at any point along top rail, & have attachment devices & supporting structure to transfer this loading to appropriate structural elements of the building. cable-rail guardrail: stainless steel shaped guard-railing w/ 1 1/2” sq. stainless steel tube rail posts @ approx. 2’-6” o.c. see details for bolted connections, typical. with 1/4” dia. horiz. stainless steel cables @ 3" o.c. by Cable-Rail® where shown, installed per manuf. specs., typical, u.n.o. 0 2'4'8' 0 2'4'8' roof & 2'-0" (min.) chimney clearance above all roofs within 10'-0" per sec. R 1003.9, 2013 CRC. Sydney Peak “Azul Blend” by GraniteRock required, contractor shall provide a copy of the manuf. U .L . Listing for any new chimney rain caps/shrouds, per sec. 2113A .9.1, 2013 CBC. typical, u.n.o. b . adhered stone veneer new thin stone veneer at chimney per exterior elevations per details. install all stone per manuf. specs – see note #5.d. above, typical, u.n.o. 13. Attic Exhaust Vents see details & cross sections for more info. a . existing attic vents existing eave & roof mounted vents to remain where occurs at existing attics to remain, typical, u.n.o. b . new attic ventilation: none required or provided at new roofs per sec. 806.4.5.1, 2013 CRC. use open cell spray polyurethane foam insulation at attic/roof. 14. Site Grading see site plan and Grading & Drainage plans by Jakaby Engineering for more info. a . existing grade to be cut and filled as shown on Grading & Drainage plan, typical u.n.o. b . finish grade to slope 5% min. away from base of building at soil and 2% min. at paving, per sec. R300.2, 2013 CRC in accordance w/ 2013 CGBSC, chapter 4, Division 4.1. typical, u.n.o. 15. New Exterior Trellises all lumber to be S4S clear cedar - see details for more info., typical, u.n.o. 1 ½” thick x 2” sq. bar spaces - GIA-200-2 aluminum I-Bar grating - as manuf. by McNichols over 6x cantilevered cedar trellis beams per details, typical, u.n.o. 16. Landscaping See landscape drawings by Johnna Brooks – Divine Nature Landscape Design, typical, u.n.o. 17. Retaining Walls and Landscape Walls see geotechnical report by Murray Engineers, Inc. & grading and drainage plan by Jakaby Engineering for more info. See landscape architect’s drawings, details, & cross sections for more details & specs, typical, u.n.o. a . board formed concrete retaining walls install new board formed poured in place colored concrete retaining walls where show. See structural engineering drawings and details for more info. typical, u.n.o. b . board formed concrete landscape walls 3’-0” max. height board formed concrete - see landscape drawings for more info, typical, u.n.o. c . french drains at all retaining walls 4” dia. perforated pipe at base of retaining walls. slope @ 1% min., connect to underground tight line & daylight at energy dissipaters as shown on grading plan. 18. Wood Decks/Stairs stoops at all exterior doors shall conform to sec. 1008.1.4 & sec. 1008.1.5, 2013 CBC. New 5/4 x 6 IPE decking, over 2x8 ACQ p.t .d .f . deck joists @ 16” o.c. with 6x8 ptdf girders per structural framing plans, typical, u.n.o. use stainless steel screws, verify attachment methods in field with Architect. 19. Rear Deck Guardrails see exterior elevations, and details for more info, typical. final design & shop drawings for exterior guardrail design to be handled as a deferred submittal by the Contractor & submitted to Bldg. Dept., owner, & architect for approval prior to fabrication, typical, u.n.o. guardrail system shall conform to 2012 IRC, sec. R 312, and sec. 1013 & sec. 1607A .7, 2013 CBC: for 200 lb. concentrated loading applied in any direction at any point along top rail, & have attachment devices & supporting structure to transfer this loading to appropriate structural elements of the building. cable-rail guardrail: stainless steel shaped guard-railing w/ 1 1/2” sq. stainless steel tube rail posts @ approx. 2’-6” o.c. see details for bolted connections, typical. with 1/4” dia. horiz. stainless steel cables @ 3" o.c. by Cable-Rail® where shown, installed per manuf. specs., typical, u.n.o. EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if 12'-1"10'-1"4'-0"26'-0"T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> SUBFLOOR @ MAIN FLOOR AVG. EXISTING GRADE 604.43' 612.51'8'-1"616.51' 604.43' 612.51'±8'-1"614.51' 598.24' 624.24' 617.87' T.O. <N> PLATE @ NOOK T.O. <N> PLATE @ KITCHEN T.O. <E> PLATE @ BDRM. #2 T.O. <N> PLATE @ DINING ROOM 12 ±5EXIST'G. 12 ±5 EXIST'G. CANTILEVER *TEMP.* <N> <N><N> <N><N> <N><N> <N><N> <N><N>*TEMP.*<N> <N> <N><N> *TEMP.**TEMP.* <N><N> EXISTING DRIVEWAY FINISH GRADE 26'-0" MAX. HT. APEX OF (E) ROOF EXISTING GRADE FINISH DRIVEWAY 5c (N) HORIZONTAL EXTERIOR WOOD SIDING, TYPICAL 5a (N) STUCCO SIDING, TYPICAL 1 (N) CLASS A COMP. SHINGLE ROOFING SYSTEM - TYP. U.N.O. <N><N> 1b (N) FLAT ROOFING SYSTEM, TYPICAL 15 (N) METAL TRELLIS 12'-1"12'-1"±8'-9"26'-0"3'-2"4'-3"25'-0"T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> PLATE @ LOWER FLOOR AVG. EXISTING GRADE (E) GRADE 604.43' 612.51'8'-1"616.51' 604.43' 612.51'8'-1"616.51' 594.93' 603.68' 598.24' 624.24' 617.87' 12 ±5EXIST'G. T.O. <E> PLATE @ LIVING RM. T.O. <N> PLATE @ MASTER BEDRM. T.O. <N> PLATE @ NOOK T.O. <N> PLATE @ KITCHEN <N> *TEMP.* <N> *TEMP.* <N><N> <N><N> <N><N> <N><N><N> <N><N><N> <N> <E><E> <E> <N> EXISTING DRIVEWAY NEW DRIVEWAY 26'-0" MAX. HT. APEX OF (E) ROOF EXISTING GRADE <N><N> 5d (N) WOOD WINDOW TRIM @ HORIZONTAL SIDING, TYPICAL 2b (N) METAL GUTTERS & DOWNSPOUTS, TYP. 5d (N) WOOD WINDOW TRIM @ STUCCO SIDING, TYPICAL 5d (N) WOOD DOOR TRIM @ STUCCO SIDING, TYPICAL 5e (N) NATURAL STONE VENEER WALL FINISH - TYP.NEW DRIVEWAY 15 (N) METAL TRELLIS 19 (N) CABLE GUARD RAIL 18 (N) IPE DECK & FACING SLATS 17b (N) CONCRETE GARDEN WALLS 5a NEW STUCCO WALL FINISH MAX. BLDG. HT.(EXISTING & NEW)2a 5c 5b (N) WEST ELEVATION SCALE: 1/4" = 1'-0" (N) NORTH ELEVATION SCALE: 1/4" = 1'-0" 77 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A5.1 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' 0 2'4'8' EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if roof & 2'-0" (min.) chimney clearance above all roofs within 10'-0" per sec. R 1003.9, 2013 CRC. Sydney Peak “Azul Blend” by GraniteRock required, contractor shall provide a copy of the manuf. U .L . Listing for any new chimney rain caps/shrouds, per sec. 2113A .9.1, 2013 CBC. typical, u.n.o. b . adhered stone veneer new thin stone veneer at chimney per exterior elevations per details. install all stone per manuf. specs – see note #5.d. above, typical, u.n.o. 13. Attic Exhaust Vents see details & cross sections for more info. a . existing attic vents existing eave & roof mounted vents to remain where occurs at existing attics to remain, typical, u.n.o. b . new attic ventilation: none required or provided at new roofs per sec. 806.4.5.1, 2013 CRC. use open cell spray polyurethane foam insulation at attic/roof. 14. Site Grading see site plan and Grading & Drainage plans by Jakaby Engineering for more info. a . existing grade to be cut and filled as shown on Grading & Drainage plan, typical u.n.o. b . finish grade to slope 5% min. away from base of building at soil and 2% min. at paving, per sec. R300.2, 2013 CRC in accordance w/ 2013 CGBSC, chapter 4, Division 4.1. typical, u.n.o. 15. New Exterior Trellises all lumber to be S4S clear cedar - see details for more info., typical, u.n.o. 1 ½” thick x 2” sq. bar spaces - GIA-200-2 aluminum I-Bar grating - as manuf. by McNichols over 6x cantilevered cedar trellis beams per details, typical, u.n.o. 16. Landscaping See landscape drawings by Johnna Brooks – Divine Nature Landscape Design, typical, u.n.o. 17. Retaining Walls and Landscape Walls see geotechnical report by Murray Engineers, Inc. & grading and drainage plan by Jakaby Engineering for more info. See landscape architect’s drawings, details, & cross sections for more details & specs, typical, u.n.o. a . board formed concrete retaining walls install new board formed poured in place colored concrete retaining walls where show. See structural engineering drawings and details for more info. typical, u.n.o. b . board formed concrete landscape walls 3’-0” max. height board formed concrete - see landscape drawings for more info, typical, u.n.o. c . french drains at all retaining walls 4” dia. perforated pipe at base of retaining walls. slope @ 1% min., connect to underground tight line & daylight at energy dissipaters as shown on grading plan. 18. Wood Decks/Stairs stoops at all exterior doors shall conform to sec. 1008.1.4 & sec. 1008.1.5, 2013 CBC. New 5/4 x 6 IPE decking, over 2x8 ACQ p.t .d .f . deck joists @ 16” o.c. with 6x8 ptdf girders per structural framing plans, typical, u.n.o. use stainless steel screws, verify attachment methods in field with Architect. 19. Rear Deck Guardrails see exterior elevations, and details for more info, typical. final design & shop drawings for exterior guardrail design to be handled as a deferred submittal by the Contractor & submitted to Bldg. Dept., owner, & architect for approval prior to fabrication, typical, u.n.o. guardrail system shall conform to 2012 IRC, sec. R 312, and sec. 1013 & sec. 1607A .7, 2013 CBC: for 200 lb. concentrated loading applied in any direction at any point along top rail, & have attachment devices & supporting structure to transfer this loading to appropriate structural elements of the building. cable-rail guardrail: stainless steel shaped guard-railing w/ 1 1/2” sq. stainless steel tube rail posts @ approx. 2’-6” o.c. see details for bolted connections, typical. with 1/4” dia. horiz. stainless steel cables @ 3" o.c. by Cable-Rail® where shown, installed per manuf. specs., typical, u.n.o. roof & 2'-0" (min.) chimney clearance above all roofs within 10'-0" per sec. R 1003.9, 2013 CRC. Sydney Peak “Azul Blend” by GraniteRock required, contractor shall provide a copy of the manuf. U .L . Listing for any new chimney rain caps/shrouds, per sec. 2113A .9.1, 2013 CBC. typical, u.n.o. b . adhered stone veneer new thin stone veneer at chimney per exterior elevations per details. install all stone per manuf. specs – see note #5.d. above, typical, u.n.o. 13. Attic Exhaust Vents see details & cross sections for more info. a . existing attic vents existing eave & roof mounted vents to remain where occurs at existing attics to remain, typical, u.n.o. b . new attic ventilation: none required or provided at new roofs per sec. 806.4.5.1, 2013 CRC. use open cell spray polyurethane foam insulation at attic/roof. 14. Site Grading see site plan and Grading & Drainage plans by Jakaby Engineering for more info. a . existing grade to be cut and filled as shown on Grading & Drainage plan, typical u.n.o. b . finish grade to slope 5% min. away from base of building at soil and 2% min. at paving, per sec. R300.2, 2013 CRC in accordance w/ 2013 CGBSC, chapter 4, Division 4.1. typical, u.n.o. 15. New Exterior Trellises all lumber to be S4S clear cedar - see details for more info., typical, u.n.o. 1 ½” thick x 2” sq. bar spaces - GIA-200-2 aluminum I-Bar grating - as manuf. by McNichols over 6x cantilevered cedar trellis beams per details, typical, u.n.o. 16. Landscaping See landscape drawings by Johnna Brooks – Divine Nature Landscape Design, typical, u.n.o. 17. Retaining Walls and Landscape Walls see geotechnical report by Murray Engineers, Inc. & grading and drainage plan by Jakaby Engineering for more info. See landscape architect’s drawings, details, & cross sections for more details & specs, typical, u.n.o. a . board formed concrete retaining walls install new board formed poured in place colored concrete retaining walls where show. See structural engineering drawings and details for more info. typical, u.n.o. b . board formed concrete landscape walls 3’-0” max. height board formed concrete - see landscape drawings for more info, typical, u.n.o. c . french drains at all retaining walls 4” dia. perforated pipe at base of retaining walls. slope @ 1% min., connect to underground tight line & daylight at energy dissipaters as shown on grading plan. 18. Wood Decks/Stairs stoops at all exterior doors shall conform to sec. 1008.1.4 & sec. 1008.1.5, 2013 CBC. New 5/4 x 6 IPE decking, over 2x8 ACQ p.t .d .f . deck joists @ 16” o.c. with 6x8 ptdf girders per structural framing plans, typical, u.n.o. use stainless steel screws, verify attachment methods in field with Architect. 19. Rear Deck Guardrails see exterior elevations, and details for more info, typical. final design & shop drawings for exterior guardrail design to be handled as a deferred submittal by the Contractor & submitted to Bldg. Dept., owner, & architect for approval prior to fabrication, typical, u.n.o. guardrail system shall conform to 2012 IRC, sec. R 312, and sec. 1013 & sec. 1607A .7, 2013 CBC: for 200 lb. concentrated loading applied in any direction at any point along top rail, & have attachment devices & supporting structure to transfer this loading to appropriate structural elements of the building. cable-rail guardrail: stainless steel shaped guard-railing w/ 1 1/2” sq. stainless steel tube rail posts @ approx. 2’-6” o.c. see details for bolted connections, typical. with 1/4” dia. horiz. stainless steel cables @ 3" o.c. by Cable-Rail® where shown, installed per manuf. specs., typical, u.n.o. EXTERIOR ELEVATION NOTES 1. Class A Roofing System install new Class A roofing systems over 30# felt over ½” exterior grade sheathing o/ new/existing 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3 :12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1 /4 ” per ft. slope min.) installed per manuf. specs., over 1/2" exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. see roof plan, roof framing plan, details for more info., typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan & grading plans by Jakaby Engineering for more surface drainage info., typical, u.n.o. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per 2013 CMC sec. 504.5, sec. 510.8.2 & sec. 510.8.3, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per 2013 CPC sec. 510.5.2, sec. 906.1, & sec. 906.2, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per 2013 CRC sec. R905.2.8.2(2 ), typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC, typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. Exterior Siding & Trim as required by new work, remove existing batts at existing plywood siding where indicated. protect existing stud wall framing to remain as much as is possible & practical, and patch and repair existing 1x exterior siding & gypsum board finish to remain as required by new work. install gyp. bd. per sec. R702.3, 2013 CRC. use precast GFRC conc. lintel head trim at stone headers, typical, u.n.o. Sydney Peak Stone “Azul Blend” by GraniteRock a . exterior stucco siding 7/8" thick min. 3-coat stucco with smooth steel trowel finish, o/ heavy duty wire lath, o/ 2 layers class "d" building paper, o/ Tyvek®, o/ 1/2" cdx plywood sheathing per 2013 CRC sec. R 703.2 & sec. R703.6, o/ 2x d.f. studs @ 16" o.c., w/ weep screed @ base per 2013 CRC sec. R703.6.2.1, typical, u.n.o. b . horizontal wood siding (below decks): 5/4 x 5 1/2" S 4 S kiln dried clear cedar siding o/ 3/8” thick vertical spacers @ 24” o.c., o/ 4x4 posts deck assembly (see details), typical, u.n.o. c . horizontal wood siding : 3/4 x 5 1/2" S 4 S kiln dried clear cedar t&g siding o/ 3/8” thick vertical spacers @ 24” o.c., o/exterior rain-screen assembly, typical, u.n.o. d . exterior wood trim: 1x / 2x kiln-dried stain grade cedar trim (back- stained) @ new windows & doors, and misc. trim where occurs, typical, u.n.o. e . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations/ installed per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 6. Exterior Painting provide stain samples on shingle samples for approval by owner & architect, typical, u.n.o. apply all paint and stain finishes strictly per manufacturer’s specs, typical, u.n.o. back-stain all fascias and trim prior to installation. a . surface preparation: thoroughly clean exterior surfaces of all dirt, dust, grease, etc. prior to painting/staining. thoroughly caulk, spackle, fill, and sand smooth all cracks, splits, holes, etc. at all affected areas prior to painting, typical, u.n.o. b . exterior siding & trim: provide one coat primer, two coats SAFECOAT by AFM, or equiv. flat latex zero VOC at stucco siding, trim, at entire house. c . exterior wood siding: provide two coats clear stain/sealer by Cabots, or equiv. at all stain grade trim, barge board, posts/columns, window/door trim, trellises, etc. d . exterior trim: provide one coat primer, two coats semi-gloss paint or stain at all eaves, trim, soffits, barge board, posts/columns, window/door trim, etc. 7. Windows refer to window schedule for more info. typical 8. Foundation Vents crawl space 1,885 s.f. total area 150 s.f. total s.f. vents 12.60 s.f. where possible align vents at centerline of new windows, or as shown. a . new addition provide 6" x 14" g.i. screened vents @ approx. 4'-0" o.c. at perimeter (min. of 22 total vents at existing house & addition, see exterior elevs.), per sec. 1203.3, 2013 CBC, typical, u.n.o. b . existing residence contractor to verify that ventilation at existing crawl space is adequate as req’d. by 2013 CBC. 9. Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 10. New E ntry Door & Sidelites provide allowance/install new pivot hinge main entry door and tempered glass sidelites at location indicated. see door schedule for more info, typical, u.n.o. 11. New Overhead Garage Door provide/install new overhead garage doors at location indicated. see door schedule for more info, typical, u.n.o. 12. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if 8'-10"12'-1"±8'-9"±8'-9"26'-0"T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> SUBFLR. @ MAIN FLOOR T.O. <E> PLATE @ LOWER FLOOR T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> PLATE @ LOWER FLOOR AVG. EXISTING GRADE 604.43' 612.51'8'-1"613.26' 604.43' 612.51'8'-1"616.51' 594.93' 603.68' 594.93' 603.68' 598.24' 624.24' 617.87' 12 ±5EXIST'G. 12 ±5 EXIST'G. T.O. <E> PLATE @ LIVING RM. T.O. <N> PLATE @ OFFICE T.O. <E> PLATE @ MASTER BEDRM. & MASTER BATH T.O. <N> PLATE @ MASTER BEDRM. & MASTER BATH DORMER <N> <N> *TEMP.* <N> <N><N><N> <N><N><N><N><N> <N> *TEMP.* <N> <N><N><N><N> <N> <E><E> <E> <E> <E><E><E><E> <E> *TEMP.* <N> <N><N><N><N><N><N> <N><N> EXISTING GRADE EXISTING GRADE 26'-0" MAX. HT. APEX OF (E) ROOF 5a (N) STUCCO SIDING, TYPICAL 1 (N) CLASS A COMP. SHINGLE ROOFING SYSTEM - TYP. U.N.O. 5e (N) NATURAL STONE VENEER WALL FINISH - TYP. 1b (N) FLAT ROOFING SYSTEM, TYPICAL @ DORMERS 7 NEW ALUM. CLAD WOOD FRAME WINDOWS, TYP. 5a NEW STUCCO SIDING, TYP. 5c NEW STONE VENEER 8'-10"26'-0"T.O. <E> SUBFLOOR @ MAIN FLOOR T.O. <E> SUBFLOOR @ MAIN FLOOR AVG. EXISTING GRADE 604.43' 612.51'8'-1"604.43' 612.51'8'-1"613.26' 598.24' 624.24' 617.87' 12 ±5EXIST'G. 12 ±5 EXIST'G. T.O. <E> PLATE @ BEDRM. #2 T.O. <E> PLATE @ BEDRM. #3 T.O. <N> PLATE @ OFFICE <N><N> <E><E><E> <E><E> <E><E> EXISTING GRADE 26'-0" MAX. HT. APEX OF (E) ROOF 5d (N) WD. WDW. TRIM @ HORIZ. SIDING, TYPICAL 2b (N) METAL GUTTERS & DOWNSPOUTS, TYP. 5d (N) WOOD WINDOW TRIM @ STUCCO SIDING, TYPICAL 5d (N) WOOD DOOR TRIM @ STUCCO SIDING, TYPICAL 5c (N) HORIZONTAL EXTERIOR WOOD SIDING, TYPICAL 1 EXIST'G. ROOF TO REMAIN - PATCH AS REQUIRED 2b NEW G.I. GUTTERS & DOWNSPOUTS, TYP. 19 CABLE RAIL GUARDRAIL 5b IPE DECKS AND WOOD SLATS 2a 2a (N) EAST ELEVATION SCALE: 1/4" = 1'-0" (N) SOUTH ELEVATION SCALE: 1/4" = 1'-0" 78 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A6.0 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects ROOF PLAN NOTES 1. Class A Roofing System install all new Class A roofing systems over ½” exterior grade sheathing o/ new 2x d .f . rafters @ spacing per structural drawings. use LP FlameBlock®, ICC certified (ESR-1365) fire rated OSB sheathing as req.d for UWIC fire code, wall assembly. a . composition shingle roofing system Class A composition shingle roofing system CertainTeed Landmark TL “Weathered Wood”, over existing and new roof framing system at new sloped roofs, typical, u.n.o. b . Class A “flat” roofing system: < 3:12 Class A - IB Roof Systems (UL-R 15546 & ICC-ES Evaluation Report ESR-2852), “Brown” Single Ply Mechanically Attached Membrane Roofing System w/ heat welded seams o/ tapered Polyiso insulation panels (1/4” per ft. slope min.) installed per manuf. specs., over 1 /2 " exterior grade OSB or CDX Structural I sheathing, typical, u.n.o. 2. Gutters and Downspouts see eave details for more info., typical, u.n.o. see site plan for more surface drainage info., typical, u.n.o. provide option for “Green Screen” or equiv. leaf screens at all gutters. finalize all downspout locations with walk through in field with architect prior to setting underground drainage piping. a . gutters 5” fascia 24 ga. bonderized rectangular fascia gutters w/ gutter cover screen mesh as required to prevent accumulation of leaves/debris in gutters per sec. R327.5.4, 2013 CRC, typical, u.n.o. b . downspouts 3" sq. 24 ga. bonderized downspouts -connect downspouts at grade to 4” min. dia. HDPE tight drain lines and run to infiltration structures per Grading and Drainage Plan, typical, u.n.o. 3. Roof Jacks provide neoprene gaskets & g.i. roof jack/ rain cap. paint to match roof color & locate where not visible from street wherever possible, typical, u.n.o. a . exhaust vents all exhaust vents shall be located a min. of 3' from or 1' above all roof or wall openings per sec. 504.5, sec. 510.8.2 & sec. 510.8.3, 2013 CMC, typical, u.n.o. b . plumbing vents all plumbing vents to be located a min. of 10' from or 3' above roof or wall openings per sec. 510.5.2, sec. 906.1, & sec. 906.2, 2013 CPC, typical, u.n.o. 4. Flashing 26 ga. g.i. flashing per sec. R905.2.8, 2013 CRC for asphalt shingle roofing systems. see roof plan and details for more info., typical, u.n.o. a . valley flashing 26 ga. g.i. "w " flashing over cont. 36” wide (min.) extra layer of 30# felt @ all valleys, per sec. R 905.2.8.2(2 ), 2013 CRC. typical, u.n.o. b . step flashing 26 ga. g.i. step "L " flashing per details at roof & under ext. wall siding, and per sec. R905.2.8.3, 2013 CRC. typical, u.n.o. c . pitch break flashing 26 ga. g.i. "L " flashing @ all wall to pitched roofs, per sec. R905.2.8.3, 2013 CRC. typ., u.n.o. d . cricket flashing 26 ga. g.i. flashing over 1/2" cdx plywood cricket, over 2x4 d.f. framing @ 24" o.c. (as occurs), with 1/4"/ft. min. slope to drain, typical, u.n.o. e . window/door head flashing 26 ga. g.i. "Z " flashing above windows & doors, typical, u.n.o. 5. California Framing see roof plan & roof framing plan for shaded areas indicating California framing. 2x12 continuous nailer for new rafters over roof sheathing. see structural framing plan & details for more info., typical, u.n.o. 6. Raftertails/Barge Rafter/Fascia all trim lumber to be paint grade Advantage Plus treated fascia/barge board & trim by Kelleher Corp.® pre- primed fascia/trim. a . barge rafter/molding assembly continuous g.i. drip edge flashing per 2013 CRC sec. 905.2.8.5, over 1x2 pre-primed shingle strip o/ moulding per rake details, o/ 2x Clear Lam® pre-primed barge rafter (to match existing). see rake details for more info., typical, u.n.o. 7. Attic Exhaust Vents a . existing attic vents existing eave & roof mounted vents to remain where occurs at existing attics to remain, typical, u.n.o. b . new attic ventilation: none required or provided at new roofs per sec. 806.4.5.1, 2013 CRC. use open cell spray polyurethane foam insulation at attic/roof. 8. Existing Fireplace and Chimney verify existing 3’-0” (min.) chimney clearance above the highest point where the chimney passes through the roof & 2'-0" (min.) chimney clearance above all roofs within 10'-0" per sec. R 1003.9, 2013 CRC. Sydney Peak Stone “Azul Blend” by GraniteRock a . existing fireplace to remain contractor to protect existing masonry fireplace, firebox, and masonry chimney to remain from damage during construction typical, u.n.o. verify existing, or provide new & install approved spark arrestor per sec. R1003.9.1, 2013 CRC. if required, contractor shall provide a copy of the manuf. U .L . Listing for any new chimney rain caps/shrouds, per sec. 2113A .9.1, 2013 CBC. typical, u.n.o. b . adhered stone veneer new natural thin stone veneer at all new wall veneer, chimney, column bases, etc. per exterior elevations and battered per details. install all stone per manuf. specs, w/deep mortar joints (dry laid look), o/ 3/4” to 1” mortar bed over stucco wire lath, o/ Cadco J -drain #303 (or equiv.) drainage blanket, typical, u.n.o. 9 . New Trellises all lumber to be S4S clear cedar - see details for more info., typical, u.n.o. 1 ½” thick x 2” sq. bar spaces - GIA-200-2 aluminum I-Bar grating - as manuf. by McNichols over 6x cantilevered cedar trellis beams per details, typical, u.n.o. 0 2'4'8' A A1.2 A A1.2 B A1.2 B A1.2 C A1.2 C A1.2 D A1.3 D A1.3 E A1.3 E A1.3 F A1.3 F A1.3 LOW SLOPE (VERIFY) <N> LOW SLOPE (VERIFY) <N>LOW SLOPE(VERIFY)<N>LOW SLOPE (VERIFY) <N> LOW SLOPE (VERIFY) <N>LOW SLOPE(VERIFY)<N>LOW SLOPE(VERIFY)<N>LOW SLOPE (VERIFY) <N> LOW SLOPE (VERIFY) <N> LOW SLOPE (VERIFY) <N>LOW SLOPE(VERIFY)<N>LOW SLOPE(VERIFY)<N>LOW SLOPE(VERIFY)<N>LOW SLOPE (VERIFY) <N> LOW SLOPE (VERIFY) <N> LOW SLOPE (VERIFY) <N>LOW SLOPE(VERIFY)<N>LOW SLOPE (VERIFY) <N>ROOFPITCH<E> 5:12ROOFPITCH<E>5:12ROOF PITCH <E> 5:12 ROOF PITCH <E> 5:12 ROOF PITCH <E> 5:12 ROOF PITCH <E> 5:12 <N> DECK BELOW <E> DECK BELOW <N> DECK BELOW ROOFPITCH<N> 5:12ROOFPITCH<E> 5:12ROOFPITCH<E> 5:12<N> D.S. <E> ROOF LINE <E> ROOF LINE <E> ROOFLINE<E> ROOF LINE <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. <N> D.S. 1b LOW SLOPE/"FLAT" ROOFING SYSTEM 1 EXISTING COMP. SHINGLE ROOF 1 EXISTING COMP. SHINGLE ROOF 1b LOW SLOPE/"FLAT" ROOFING SYSTEM 2a NEW METAL GUTTERS, TYPICAL 2b NEW METAL DOWNSPOUT, TYPICAL (N) ROOF PLAN SCALE: 1/4" = 1'-0" 79 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A10.0 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' ALL OUTLETS, SWITCHES, FIXTURES, ETC. MARKED AS <E> ARE EXISTING TO REMAIN. THOSE MARKED AS <R> ARE TO BE RELOCATED AS SHOWN, AND PER OWNER'S SPECIFICATIONS. <E> <S> <R> NOTE: EXISTING ITEMS TO BE REMOVED, TYPICAL, U.N.O. EXISTING SALVAGED EXISTING WALL TO BE REMOVED, TYPICAL, U.N.O. EXISTING MASONRY WALL TO BE REMOVED, TYPICAL, U.N.O. EXISTING WALL TO REMAIN, TYPICAL, U.N.O. DEMOLITION LEGEND 598 596 594 592 602 (E) 6" ORNAM. (E) 30" OAK (E) 35" OAK (E) 26" OAK (E) 24" OAK (E)11" OAK (E)13" OAK (E) 25" OAK (E)12" OAK 25'-0" EXTERIOR SIDE SETBACK<E> W.C. <E> W.C. <E> TUB <E> 40x24F.P. w/ 8" TALLHEARTH<E> SINK <E> SINK *TEMP*<E> 39x23 F.P. w/ 14 TALL HEARTH DN5R @ ±7½" EA.DN10R@ ±7" EA.<E>RE F R I G .<E>D.W.<E><E> CABINETRY <E> 29x68 C.O. M. BATH <E> 80 FLAT CLG. <E> TILE M. CLOS. <E> 80 FLAT CLG. <E> HARDWD. FLR'G. B.R. HALL <E> 80 FLAT CLG. <E> HARDWD. FLR'G. <E> PR. 28x68 SLID'G. DRS. <E> PR. 28x68 SLID'G. DRS. BATH #2 <E> 80 FLAT CLG. <E> TILE <E>28x68C.O.HALL <E> 80 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈604.49' <E> CABINETRY <E>±108x68C.O.DECK F.F.≈604.20' DECK F.F.≈604.20'<E> PR.30X68FR. DRS.MASTER BDRM. <E> 80 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈604.49'<E>28X68DR.<E>28X68DR.<E>24X68DR.<E>24X68DR.BEDROOM #2 <E> 80 FLAT CLG. <E> HARDWD. FLR'G. <E> 30X42 CSMNT. @68 HDR. <E> 30X42 CSMNT. @68 HDR.<E>30X22CSMNT.@68 HDR.<E>16X22CSMNT.@68 HDR.<E>16X22CSMNT.@68 HDR.<E>28X68DR.<E >28X68DR. <E> 20X32 CSMNT. @68 HDR.<E> PR.20X32CSMNTS.@68 HDR.<E> DR.<E> PR.30X42CSMNTS.@68 HDR.<E> PR.30X42CSMNTS.@68 HDR.<E>38X42FIXED@68 HDR.<E>20X42CSMNT.@68 HDR.<E>20X42CSMNT.@68 HDR . <E> ±40X62 CSMNT. @68 HDR. < E > ±40X62CSM N T . @6 8 HDR .<E>±4 0 X 6 2 CSMNT.@6 8 HDR. LIVING ROOM <E> VLT'D. CLG. w/ BEAMS <E> HARDWD. FLR'G.<E>DR.<E> PR.24X68DR.<E>30x68DR. w/±10 S.L.<E> 40X42 CSMNT. @68 HDR. <E> 20X42 CSMNT. @68 HDR. <E> 20X42 CSMNT. @68 HDR.<E>28x68FR. DR.<E> 20x40 SKYLTS. <E> 30X44 FIXED @68 HDR.<E> PR.28X68FR. DRS.w/±10 S.L.<E> 2 8 X6 8 FR. D R.<E> PR .24X68FR. DRS .w/±13 S .L . <E> 1 4 X 5 0 CSMN T. @6 8 HDR.<E>14X50CSMNT.@68 HDR .<E> PR.20X30CSMNTS.@68 HDR.<E> P R . 20 X50CS M N T S . @68 HD R . <E> P R . 20 X50CS M N T S . @68 HD R . NOOK <E> VLT'D. CLG. w/ BEAMS <E> HARDWD. FLR'G. KITCHEN <E> 80 FLAT CLG. <E> HARDWD. FLR'G. <E> 510x45 SKYLT. WELL<E> PR.20X42CSMNTS.@68 HDR.<E>60X42FIXED@68 HDR.DINING ROOM <E> 80 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈604.49' <E> 3x6 <E> 4x12____<E>38 WIDETRAPEZOIDWDW.DN ±2½" <E> DB L . OV E N & M W <E>SINK<E> SIN K <E> DE S K <E> CA B . <E> SHELVES <E> GAS <E> ELEC. METER DN. ±4" DN. ±3½" DN. 2R DN. ±1¾" DN. ±1¾" DN. 2R DN. ±1¾" DN. ±6" <R><R><R><R><R><R><R><R><R><R><R > <R><R><R><R><R><R><R><R> <R> <R> <R> <R> <R><R><R><R><R><R> <R> <R> <R> <R><R><R><R><R> <R> <R> <R><R><R> <R><R><R> <R> <R><R><R><R><E> ATTIC ACCESS <E> <E> <E> CAR <E> <E> <E> HIG H WA L L <E> HIG H WA L L <E> <E> HIGH WALL<E> HIGH WALL <E> CAR <E> <E> <E> WALL HTR. MAIN FLR. DEMO PLAN SCALE: 1/4" = 1'-0" 80 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A10.1 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' ALL OUTLETS, SWITCHES, FIXTURES, ETC. MARKED AS <E> ARE EXISTING TO REMAIN. THOSE MARKED AS <R> ARE TO BE RELOCATED AS SHOWN, AND PER OWNER'S SPECIFICATIONS. <E> <S> <R> NOTE: EXISTING ITEMS TO BE REMOVED, TYPICAL, U.N.O. EXISTING SALVAGED EXISTING WALL TO BE REMOVED, TYPICAL, U.N.O. EXISTING MASONRY WALL TO BE REMOVED, TYPICAL, U.N.O. EXISTING WALL TO REMAIN, TYPICAL, U.N.O. DEMOLITION LEGEND <E> W.C.UP15R@ ±7¼" EA.*TEMP *<E>SINK<E>24 PKT.DR.LAUNDRY <E> ±83 FLAT CLG. w/ BEAMS <E> HARDWD. FLR'G. F.F.≈595.49'<E>29 C.O.STORAGE <E> ±80 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈595.74' BATH #2 <E> ±86 FLAT CLG. <E> TILE <E> W <E> D CELLAR/STORAGE <E> CONC. SLAB F.F.≈595.44'<E>80X762-PANELSLID'G.GLS. DRS.<E>80X762-PANELSLID'G.GLS. DRS.<E> 60X76 2-PANEL SLID'G. GLS. DRS.<E> PR.28 DR.<E>28 DR.<E> PR.20 FR.DRS.BEDROOM #4 <E> ±86 FLAT CLG. <E> HARDWD. FLR'G. F.F.≈595.20' BEDROOM #3 <E> ±89 FLAT CLG. w/ BEAMS <E> STONE TILE F.F.≈594.99'<E>28 DR.<E>24 DR.<E>26 DR.<E> 30X53 CSMNT. @83 HDR. <E> 30X53 FIXED @83 HDR. <E> 30X53 FIXED @83 HDR. <E> 30X53 FIXED @83 HDR. <E> 10X53 FIXED <E>±34X53FIXED@83 HDR.<E>±34X53FIXED@83 HDR.<E>±34X53FIXED@83 HDR.<E>±34X53FIXED@83 HDR.<E>±34X53FIXED@83 HDR.<E> 30X53 CSMNT. @83 HDR. <E> 30X53 FIXED @83 HDR. <E> 30X50 FIXED @83 HDR. <E> 30X24 FIXED @83 HDR. <E> 30X24 FIXED @83 HDR.<E>50X53FIXED@76 HDR.<E> 18X76 FIXED @76 HDR. <E> PR. 20X42 CSMNTS. @±70 HDR. <E> PR. 20X42 CSMNTS. @±70 HDR.<E>20X32CSMNT.FAMILY ROOM <E> ±96 FLAT CLG. w/ BEAMS <E> STONE TILE & CONC. SLAB F.F.≈594.11'<E> 4x14 BEAMS<E> 4x14 BEAM <E> 4x8 BEAMSREMOVE (E) BRICK REMOVE (E) BRICK (E) CONC. SLAB TO BE REMOVED UP ±6" UP ±2½" UP ±3" UP ±5" UP ±5½" DN. ±1¼" DN 2 R @± 5 ¼" E A . <E> SUB PANEL <E> GAS UP ±5½" DN. ±3¾"DN.±2½DN.±2"<R> <S> <S><R><R><R> <R><R><R><R><R><R><R><R><R><R><R><R> <S> <R><R> <R> <E> <E> HIGH WALL - - <E> HIGH WALL <E> HIGH WALL <E> LOW WALL - LOWER FLR. DEMO PLAN SCALE: 1/4" = 1'-0" 598 596 594 592 (E) 6" ORNAM. (E) 30" OAK (E) 35" OAK (E) 26" OAK (E) 24" OAK (E)11" OAK (E)13" OAK (E) 25" OAK (E)12" OAK 25'-0" EXTERIOR SIDE SETBACK81 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A10.2 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' 0 2'4'8' T.O. <E> SUBFLOOR @ MASTER BEDRM. T.O. <E> SUBFLOOR @ KITCHEN ±8'-1"612.53' 604.45'604.45' 612.53'±8'-1"T.O. <E> PLATE @ MASTER BEDRM. T.O. <E> PLATE @ KITCHEN <E> <E> <E><E> <E><E> 12 ±5EXIST'G. 12 ±5 EXIST'G.12 ±5 EXIST'G. <E><E> EXISTING GRADE <R> <R><R><R> <R><R> <R><R> T.O. <E> SUBFLOOR @ DINING ROOM T.O. <E> SUBFLOOR @ FAMILY ROOM T.O. <E> SUBFLOOR @ KITCHEN 604.45' 612.53'±8'-1"594.07' 603.64'±9'-7"±8'-1"612.53' 604.45' <E><E> <E><E><E><E> <E><E><E><E><E><E> <E><E><E><E> <E><E> 12 ±5EXIST'G. 12 ±5 EXIST'G. T.O. <E> PLATE @ DINING ROOM T.O. <E> PLATE @ FAMILY ROOM T.O. <E> PLATE @ KITCHEN EXISTING GRADE <R><R> <R><R><R><R> <R><R><R><R><R><R> <R> (E) WEST ELEVATION SCALE: 1/4" = 1'-0" (E) NORTH ELEVATION SCALE: 1/4" = 1'-0" 82 EC TTRCHAI REN._______ No. C 018234 1/1/18 NOEL F. CROSS DE L NEC SI SETAT OF C FILA O RNAI G ! this symbol calls attention to a !green! materi al or const ruction process" the g e n e r a l c o n t r a c t o r a n d a l l s u b c o n t r a c t o r s s h a l l g i v e s p e c i a l a t te nt ion to l ocati n g# p ro c u ri ng # and installing this specific material# or one t h a t i s a s e q u a l l y environmentally sustainable" in many cases vendor phone numbers have been included" call the architect in the event you cannot locate the specified material" NFC PROJECT DATA 14.01 NFC/DSK/JIF A10.3 2/16/17 Date Drawn By Checked By Project No. Sheet No. ARCHITECT The plans, ideas arrangements, and designs indicated or represented by this drawing are owned by, and are the property of the Architect and were created and developed solely for use on, and in connection with this specific project, and shall not be used, in whole or in part, for any purpose for which they were not originally intended without written permission from: NOEL F. CROSS, ARCHITECT, A.I.A. Of date printed: Occupancy Construction Property Owners Project Address Kevin Tsai Jacqueline Chow Phone (408) 218-8188 Parcel Gross Site Area Zoning 3.970 acres 172,933 sq. ft. R-3 & U R-1-40,000 Single Family Residential City of Saratoga Setbacks 20972 Saratoga Hills Rd. Saratoga, CA 95070 APN: 503-29-034 Front: 30'-0" Ext. Side: 25'-0" Int. Side: 20'-0" Max. Ht.: 26'-0" Type V-B Revisions 148 E. Virginia Street #2 San Jose, CA 95112 408-216-0222 www.nfcarchitect.com TSAI REMODEL Net Site Area 1.760 acres 76,656 sq. ft. 19 OCTOBER 2016 PLANNING SUBMITTAL +Noel Cross Architects 0 2'4'8' 0 2'4'8' T.O. <E> SUBFLOOR @ BEDROOM #2 T.O. <E> SUBFLOOR @ LIVING ROOM T.O. <E> SUBFLOOR @ BEDROOM #3 604.45' 612.53'±8'-1"±8'-1"612.53' 604.45'±8'-10"603.78' 594.95' 12 ±5EXIST'G. 12 ±5 EXIST'G. <E><E><E><E><E> <E><E><E><E> <E> <E><E> <E><E><E><E> <E> <E> <E><E><E><E><E><E> T.O. <E> PLATE @ BEDROOM #2 T.O. <E> PLATE @ LIVING ROOM T.O. <E> PLATE @ BEDROOM #3 EXISTING GRADE <R><R><R><R><R> <R><R><R><R> <R> <R><R> T.O. <E> SUBFLOOR @ LIVING ROOM T.O. <E> SUBFLOOR @ BEDROOM #4 T.O. <E> SUBFLOOR @ MASTER BEDROOM ±8'-1"612.53' 604.45'±8'-7"603.78' 595.16' 604.45' 612.53'±8'-1"<E> <E><E><E> <E><E> <E><E><E><E><E><E> 12 ±5EXIST'G.12 ±5 EXIST'G. T.O. <E> PLATE @ LIVING ROOM T.O. <E> PLATE @ BEDROOM #4 T.O. <E> PLATE @ MASTER BEDROOM EXISTING GRADE <R> <R><R><R><R> (E) EAST ELEVATION SCALE: 1/4" = 1'-0" (E) SOUTH ELEVATION SCALE: 1/4" = 1'-0" 83 84 85 86 87 88 TitleDrawing NumberCAD File NameDrawn ByDatePlant Plan Front YardDN-01Jlb9.11.16TsaiTsai and Chow Residence20972 Saratoga Hills Rd Saratoga CA, 95070Designed ByJlbPhone: .408.218.8188NATURE LANDSCAPE DESIGN 650.222.0418 Planting Plan Scale:1/8"=1'-0"606608610604602600 598 596 594 7% 8% 12% 11%12½% 10 %5885867%6126 1 4 11½% 610 600610(E ) 30"OAK(E ) 35"OAK(E ) 32"OAK(E ) 26"OAK(E ) 24"OAK(E ) 8"OAK(E )10"TREE(E ) 8"TREE(E )11"TREE(E )11"OAK(E )12"OAK598602604606608612614(E )11"OAK(E )16 "TREE(E ) 8"OAK(E )10"OAK(E )14"TREE(E )10"PINE (E ) 6"ORNAM. (E ) 30 "OAK(E ) 24"OAK(E )12"PINE (E ) 28 "CYP. (E )18 "CYP. (E ) 8"TREE(E )TREEGROUP(E ) 20"OAK(E )10"OAK(E )11"OAK(E ) 8"TREE(E ) 7"OAK(E ) 30"OAK(E ) 8"TREE(E )12"OAK(E )14"OAK(E ) 32"OAK(E )16"OAK(E ) 20 "OAK(E )13 "OAK(E ) INLET (E )GARDEN(E) SWALE(E) SWALESARATOGAN 03°4 5' 2 1 " E 224. 1 6'N 65°29'30" W 80.94'N 64°55'00" W 61.26'N 48°22'00" W36.99'S 81°59'00" E 119.50' (E ) 25 "OAK(N )DRIVEWAY 578590592588586584594590592588586584582580600 602 604606608610612614 (N) RET. WALL(N) RET. WALL(N) RET. WALL(E) SWALE(N )A/C (N )LOWERSTOOP(R )#38#37#36#35#33#34#16#15#12#13#11#6#5#4#7#8#9#10#1#2#3(N) 6' HIGH DEER FENCE(N) 6' HIGH DEER FENCE (N) 6' HIGH DEER FENCE(E) SWALE575604.15T.O. CONC.603.65T.O. CONC.9½%10%10%5% MAX. (E ) D R I P L INE ±(E) DRIPLINE ±(E )POLEGU Y (E)(N)F.P. 594. 0 0604.00F.P.604.40T.O. DECKT.O.W. 593.60B.O.W. 588.60592. 8 0 F.P. T.O. W . 593 . 0 0 B.O . W . 588 . 0 0 T .O .W . 5 8 8 . 5 0B.O .W . 5 8 3 . 0 0 T. O . W . 5 8 3 . 5 0 B. O . W . 5 8 2 . 0 0 T.O. W . 586. 8 0 B.O . W . 582. 7 0 T.O. W . 588. 2 5605.00F.P.B.O. W . 583. 7 0 T.O. W . 587. 0 0 B.O .W . 5 8 1 . 6 0 T.O .W . 5 8 6 . 5 0 B.O .W .592.00T.O .W .594.25 10-Torch Lily, Red Hot Poker 21-Festuca glauca 'Elijah Blue' (F. ovina var. glauca) 3-Cotinus coggygria 'Royal Purple' 2-Ribes sanguineum 6-Podocarpus elongatus 'Monmal' 6-Berberis thunbergii 'Rose Glow' 16-Phormium tenax BLK 4-Hosta x 'Patriot' 6-Hakonechloa macra 'Aureola' 5-Ceanothus 'Italian Skies' 6-Rhamnus californica 1-Miscanthus sinensis 'Grosse Fontaene' 1-Hydrangea aspera Villosa group 3-Miscanthus sinensis 'Grosse Fontaene' 10-Torch Lily, Red Hot Poker 1-Hydrangea aspera Villosa group 25-Spotted Dead Nettle 25-Spotted Dead Nettle 22-Spotted Dead Nettle 19-Chocolate Ruffles Coral Bells 26-Chocolate Ruffles Coral Bells 9-Foerster's Feather Reed Grass 9-Foerster's Feather Reed Grass 3-Blue Bird Rose Of Sharon 12-Fox Red Curly Sedge 1-Phormium tenax BLK 1-Ever Red Japanese Maple 1- 'RED Dragon' P P P P P P PP P 1-Ever Red Japanese Maple 89 TitleDrawing NumberCAD File NameDrawn ByDatePlant Plan Front Yard UnderstoryDN-02Jlb9.11.16TsaiTsai and Chow Residence20972 Saratoga Hills Rd Saratoga CA, 95070Designed ByJlbPhone: .408.218.8188NATURE LANDSCAPE DESIGN 650.222.0418 Planting Plan UnderstoryScale:3/32"=1'-0"16-Phormium tenax BLK 606608610604602600 598 596 594 7% 8% 12% 11%12½% 10 %5885867%6126 1 4 11½% 610 600610(E ) 30"OAK(E ) 35"OAK(E ) 32 "OAK(E ) 26"OAK(E ) 24"OAK(E ) 8"OAK(E )10"TREE(E ) 8"TREE(E )11 "TREE(E )11"OAK(E )12"OAK598602604606608612614(E )11"OAK(E )16 "TREE(E ) 8"OAK(E )10"OAK(E )14"TREE(E )10"PINE (E ) 6"ORNAM. (E ) 30 "OAK(E ) 24"OAK(E )12 "PINE (E ) 28 "CYP. (E )18 "CYP. (E ) 8"TREE(E )TREEGROUP(E ) 20"OAK(E )10"OAK(E )11"OAK(E ) 8"TREE(E ) 7"OAK(E ) 30"OAK(E ) 8"TREE(E )12"OAK(E )14"OAK(E ) 32"OAK(E )16"OAK(E ) 20 "OAK(E )13 "OAK(E ) INLET (E )GARDEN(E) SWALE(E) SWALESARATOGAN 03°4 5' 2 1 " E 224. 1 6'N 65°29'30" W 80.94'N 64°55'00" W 61.26'N 48°22'00" W36.99'S 81°59'00" E 119.50' (E ) 25 "OAK(N )DRIVEWAY 578590592588586584594590592588586584582580600 602 604606608610612614 (N) RET. WALL(N) RET. WALL(N) RET. WALL(E) SWALE(N )A/C (N )LOWERSTOOP(R )#38#37#36#35#33#34#16#15#12#13#11#6#5#4#7#8#9#10#1#2#3(N) 6' HIGH DEER FENCE(N) 6' HIGH DEER FENCE (N) 6' HIGH DEER FENCE(E) SWALE575604.15T.O. CONC.603.65T.O. CONC.9½%10%10%5% MAX. (E ) D R I P L INE ±(E) DRIPLINE ±(E )POLEGU Y (E)(N)F.P. 594. 0 0604.00F.P.604.40T.O. DECKT.O.W. 593.60B.O.W. 588.60592. 8 0 F.P. T.O. W . 593 . 0 0 B.O . W . 588 . 0 0 T .O .W . 5 8 8 . 5 0B.O .W . 5 8 3 . 0 0 T. O . W . 5 8 3 . 5 0 B. O . W . 5 8 2 . 0 0 T.O. W . 586. 8 0 B.O . W . 582. 7 0 T.O. W . 588. 2 5605.00F.P.B.O. W . 583. 7 0 T.O. W . 587. 0 0 B.O .W . 5 8 1 . 6 0 T.O .W . 5 8 6 . 5 0 B.O .W .592.00T.O .W .594.25 10-Torch Lily, Red Hot Poker 21-Festuca glauca 'Elijah Blue' (F. ovina var. glauca) 3-Cotinus coggygria 'Royal Purple' 2-Ribes sanguineum 6-Podocarpus elongatus 'Monmal' 6-Berberis thunbergii 'Rose Glow' 4-Hosta x 'Patriot' 6-Hakonechloa macra 'Aureola' 5-Ceanothus 'Italian Skies' 6-Rhamnus californica 1-Miscanthus sinensis 'Grosse Fontaene' 1-Hydrangea aspera Villosa group 3-Miscanthus sinensis 'Grosse Fontaene' 10-Torch Lily, Red Hot Poker 1-Hydrangea aspera Villosa group 25-Spotted Dead Nettle 25-Spotted Dead Nettle 22-Spotted Dead Nettle 19-Chocolate Ruffles Coral Bells 26-Chocolate Ruffles Coral Bells 9-Foerster's Feather Reed Grass 9-Foerster's Feather Reed Grass 3-Blue Bird Rose Of Sharon 12-Fox Red Curly Sedge 1-Phormium tenax BLK P P P P P P PP P 90 TitleDrawing NumberCAD File NameDrawn ByDatePlanting NotesDN-03Jlb9.11.16TsaiTsai and Chow Residence20972 Saratoga Hills Rd Saratoga CA, 95070Designed ByJlbPhone: .408.218.8188NATURE LANDSCAPE DESIGN 650.222.0418 Planting NotesScale: NONE12" 3" + THE LENGTH OF HOSE USED MUST BE LARGER THAN THE CIRCUMFERENCE OF THE TREE TRUNK. 3"BALL DIAMETER TO COMPLY WITH MIN. GUIDELINES AS SET FORTH BY THE AMERICAN STANDARDS FOR NURSERY STOCK LATEST EDITION 12" NOTES 1.PROVIDE MULCHED CIRCULAR SAUCER FOR INDIVIDUAL PLANTS. 2.PROVIDE FIRM WELL PROPORTIONED ROOTBALLS. CRACKED OR MUSHROOMED ROOTBALLS ARE NOT ACCEPTABLE. 3.THE 1ST ORDER LATERAL ROOTS ARE TO BE PARTIALLY EXPOSED PRIOR TO DIGGING. DIG PLANTS SO THAT BURLAP RESTS ON NO MORE THAN 1" OF SOIL ABOVE THE 1ST ORDER LATERAL ROOTS. NEVER CUT MAIN LEADER RUBBER HOSE GUY WIRE TREE WRAP (FALL SEASON ONLY IN THOSE AREAS SUBJECT TO FREEZING TEMPERATURES) REMOVE TOP 50% OF BURLAP & TWINE AND WIRE CAGE MULCH FORMED IN CIRCULAR SAUCER FINISH GRADE TURNBUCKLE W/ 4" MIN TAKEUP PVC SAFETY SLEEVE 1/2" DIA., 3'-0" LENGHT MIN. NOTCH OR DRILL 1/4" HOLE THRU STAKE 2" FROM TOP TO CONNECT GUY WIRE COVER TOP OF BALL WITH PLANTING MIXTURE. DO NOT COVER TRUNK. FIRM WELL PROPORTIONED BALL. CRACKED OR MUSHROOMED BALLS ARE NOT ACCEPTABLE. SCARIFY 4" DEEP AND RECOMPACT WOOD STAKES (3) AT 120 DEGREE SPACING SOIL BACKFILL DRIVE STAKE 24" INTO SOIL EDGE OF PAVEMENTEDGE OF BED12" MIN.12" MIN. NOTE: SEE PLAN FOR SPACING NOTES 1.PRIOR TO PLANTING PERENNIALS, THE BED IS TO BE SMOOTH WITHOUT DIPS OR RIDGES. AFTER PLANTING THE PERENNIALS, RAKE THE BED SURFACE SMOOTH PRIOR TO MULCHING. 2.PRIOR TO PLANTING GROUND COVERS, THE BED IS TO BE SMOOTH WITHOUT DIPS OR RIDGES. PLACE MULCH AND PLANT THE PEAT POT OR CELL PACK INTO THE SOIL THROUGH THE MULCH. HAND SMOOTH THE MULCH SURFACE. 3.VERTICALLY CUT THE PERIMETER ROOTS AROUND THE CIRCUMFERENCE WITH A KNIFE FOR ALL CONTAINER ROOT BOUND PLANTS PRIOR TO PLANTING. 2" DEEP MULCH FINISH GRADE 8" DEEP PRE-MIXED PLANTING SOILEDGE OF PAVEMENTEDGE OF BED4'-0" MIN.SPACING SEE PLAN 18" MIN. 6" MIN.6" MIN. SPREAD18" MIN. NOTES 1.PROVIDE MULCHED CIRCULAR SAUCER FOR INDIVIDUAL PLANTS. 2.PROVIDE FIRM WELL PROPORTIONED ROOTBALLS. CRACKED OR MUSHROOMED ROOTBALLS ARE NOT ACCEPTABLE. 3.THE 1ST ORDER LATERAL ROOTS ARE TO BE PARTIALLY EXPOSED PRIOR TO DIGGING. DIG PLANTS SO THAT BURLAP RESTS ON NO MORE THAN 1" OF SOIL ABOVE THE 1ST ORDER LATERAL ROOTS. MULCH FINISH GRADE SOIL BACKFILL REMOVE TOP 1/3 OF BURLAP INCLUDING TWINE OF BALLED AND BURLAP PLANTS. REMOVE COMPLETE CONTAINER OR PEAT POT FOR CONTAINER BROWN OR POTTED PLANTS. SCARIFY PERIMETER ROOTS OF CONTAINER ROOT BOUND PLANTS. 1. POINT OF CONNECTION - CONNECT TO EXISTING MAIN LINE IN FRONT YARD. 2. CONTRACTOR SHALL BECOME FAMILIAR WITH THE LOCATION OF EXISTING AND FUTURE UNDERGROUND SERVICES. CONTACT UNDERGROUND SERVICE ALERT (USA) AT (800) 642-2444 PRIOR TO BEGINNING WORK. CONTACT LANDSCAPE DESIGNER SHOULD ANY CONFLICTS ARISE. 3. THE IRRIGATION SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL LOCAL CODES AND REGULATIONS. 4.CONTRACTOR SHALL COORDINATE IRRIGATION INSTALLATION WITH OTHER TRADES. CONTRACTOR TO COORDINATE AND VERIFY ALL SLEEVING, PIPING, ELECTRICAL SUPPLY, POINT OF CONNECTION, ETC. 5. CONTRACTOR SHALL INSTALL NEW RAINBIRD ANTI-SIPHON VALVES. ALL DRIP VALVES SHALL BE LINE SIZED RAINBIRD LOW FLOW KITS WITH STATIC WYE FILTER, TO INCLUDE LOW FLOW VALVE, WYE FILTER AMD 30 PSI PRESURE REGULATOR. 6.INSTALL NEW HUNTER PRO-C 6 STATION INTERIOR WALL MOUNTED CONTROLLER. INSTALL FROM GFI OUTLET FROM 20AMP BEDROOM CIRCUIT IN GARAGE. 7. PROGRAMMING OF THE CONTROLLER IS THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT. 8. INSTALL NO. 14 UF DIRECT BURIAL IRRIGATION WIRE. USE EPOXY CONNECTORS AND BURY WIRE WITH MAINLINE, BUNDLED AND TAPED TOGETHER EVERY TEN FEET. 9. MAINLINE, LATERALS AND VALVES SHALL BE LOCATED IN PLANTING AREAS WHEN EVER POSSIBLE. NO FITTINGS SHALL BE LOCATED UNDER PAVEMENT OR IN SLEEVES. 10.CONTRACTOR SHALL ADJUST ALL PREASURE REGULATORS, VALVES, AND HEADS FOR OPTIMUM COVERAGE, AVOIDING MISTING, OVERSPRAY ONTO BUILDING, VEHICLES, FENCES, STRUCTURES OR PAVEMENT. 11. ALL EQUIPMENT INSTALLATION SHALL MEET THE REQUIREMENTS OF THESE NOTES AND THE CALIFORNIA LANDSCAPE STANDARDS, PUBLISHED BY THE CLCA (LATEST EDITION). 12. INSTALL SCHEDULE 40 LATERALS, MAINLINES, AND FITTINGS. MAINLINES SHALL BE INSTALLED AT A DEPTH OF 18". LATERALS SHALL BE INSTALLED AT A DEPTH OF 12". 13. INSTALL LINE SIZED GATE VALVES AS REQUIRED TO ISOLATE EACH GROUP OF VALVES. ALL VALVES SHALL BE LOCATED IN 10" ROUND VALVES BOXES. INSTALL 6" OF GRAVEL BELOW VALVE. 14. CONTRACTOR SHALL INSTALL DRIP IRRIGATION FOR POTS AND PLANTERS THAT IS ADJACENT TO HOUSE IF ANY ON PLAN. COMPONENTS SHALL BE RAINBIRD OR APPROVED EQUAL. 15.OMITTED 16.INSTALL RAINBIRD RWS-TREE WATERING SYSTEM. INSTALL ONE PER TREE. LOWEST FLOW AVALABLE. 17.DRIP IRRIGATION COMPONENTS TO BE RAINBIRD XERIGATION OR APPROVED EQUAL. 18.INSTALL CHECK VALVE IN HEADS AS REQUIRED TO ELIMINATE LOW HEAD DRAINAGE. 19.PROVIDE VALVES FOR THE FOLLOWING FRONT YARD PLANTING: 1: PERENNIALS DRIP 2: SHRUBS DRIP 3: TREES, BUBBLERS 20.CONTRACTOR SHALL PROVIDE LAMINATED, 81/2 X 11, AS-BUILT OF IRRIGATION, CLEARLY IDENTIFYING VALVE LOCATIONS AND STATION NUMBERS FOR EACH ZONE. AS-BUILT SHALL BE POSTED NEXT TO IRRIGATION CONTROLLER. IRRIGATION NOTES: TREE PLANTING SPECIFICATIONS SHRUB PLANTING SPECIFICATIONS PERENNIAL PLANTING SPECIFICATIONS Plant List Budget Common Name Botanical Name Qty Trees 6 1 1 6 Icee Blue® Yellow-Wood Podocarpus elongatus 'Monmal'6 Shrubs 24 6 6 24 Blue Bird Rose Of Sharon Hibiscus syriacus 'Blue Bird'3 Californian Lilac Ceanothus 'Italian Skies'9 Frangula californica Rhamnus californica 6 Red Flowering Currant Ribes sanguineum 2 Rough Leaved Hydrangea Hydrangea aspera Villosa group 1 Royal Purple Smoke Tree Cotinus coggygria 'Royal Purple'3 Perennials 131 4 4 131 Chocolate Ruffles Coral Bells Heuchera micrantha 'Chocolate Ruffles'45 Patriot Plantain Lily Hosta x 'Patriot'4 Spotted Dead Nettle Lamium maculatum 72 Torch Lily, Red Hot Poker Kniphofia uvaria 10 Ornamental Grasses 0 3 3 25 Elijah Blue Fescue Festuca glauca 'Elijah Blue' (F. ovina var. glauca)21 Large Fountain Maiden Grass Miscanthus sinensis 'Grosse Fontaene'3 Large Fountain Maiden Grass Miscanthus sinensis 'Grosse Fontaene'1 1 0 Total 0 Calamagrostis x acutiflora 'Karl Foerster'Calamagrostis x acutiflora 'Karl Foerster'18 91 TitleDrawing NumberCAD File NameDrawn ByDatePlant BoardDN-04Jlb9.11.16TsaiTsai and Chow Residence20972 Saratoga Hills Rd Saratoga CA, 95070Designed ByJlbPhone: .408.218.8188NATURE LANDSCAPE DESIGN 650.222.0418 Plant Board Acer Palmatum Dissectum 'RED Dragon'Acer Palmatum Emperor I Ever Red Ceanothus 'Italian Skies'California coffeeberry (Rhamnus californica) 'Eve Case' or 'Mound San Bruno' variety Dwarf Cornus kousa dogwood white Elijah Blue Fescue Grass Miscanthus sinensis 'Morning Light'Foerster's Feather Reed GrassPurple fountain grass Red Hot Pocker Phormium tenax 'All Black' Lambs Ears (BIG) StachysHeucheraAssorted Hosta Rose of Sharon, Blue Satin Rose Hibiscus Syriacus Podocarpus-elongatus-monmal "Icee Blue" Ribes sanguineum, Red Flowering Currant Hydrangea aspera Villosa group In Fall Cotinus coggygria, Smoke Tree Scale: NONEFox Red Curly Sage Ribes californicum, Hillside gooseberry Bush 92 TitleDrawing NumberCAD File NameDrawn ByDateLighting Plan Front YardDN-05Jlb9.11.16TsaiTsai and Chow Residence20972 Saratoga Hills Rd Saratoga CA, 95070Designed ByJlbNATURE LANDSCAPE DESIGN 650.222.0418 Scale:1/8"=1'-0"Lighting PlanPhone: .408.218.8188Boulder Layout Landscape Boulders FX-ZD-LM-Wall Light-BZ-1 LED-Driveway Light FX-ZD-TM-1 LED-BZ-Path Light FX-RW-Directional Driveway Light-3Led-BZ Fx-Luxor-ZD-300watt-Transformer LIGHTING NOTES: 1.LANDSCAPE CONTRACTOR TO INSTALL NEW FX LUMINAIRE MULTI-TAP TRANSFORMERS OR APPROVED SIMILAR MODEL. VERIFY IN FIELD IF POWER IS AVAILABLE FROM HOUSE INTERIOR TO LOCATE IN SIDEYARDS. THERE ARE NO EXISTING GFCI OUTLETS IN SIDEYARDS. AVAILABLE THROUGH EWING IRRIGATION. CONFIRM LOCATIONS WITH OWNER PRIOR TO INSTALL. DO NOT INSTALL ON WALL DIRECTLY ADJACENT TO LIVING SPACE, UNLESS TRANSFORMER IS MOUNTED ON A POST. 2.INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS AND/OR SPECIFICATIONS. 3.CONTRACTOR SHALL SLEEVE 120 VOLT SUPPLY WIRE 18" DEEP. 4.CONTRACTOR SHALL BURY ALL WIRING 6" DEEP. CONTRACTOR SHALL SIZE WIRE AS REQUIRED FOR RUN. LONG RUNS, GREATER THAN 75', SHALL BE 10-2 WIRE. 5.CABLE RUNS SHALL BE CALCULATED TO ALLOW FOR VOLTAGE DROP AT 10.5 MIN. 6.IN-GROUND FIXTURES EXCEPT FOR WELL LIGHT SHALL BE INSTALLED IN HOLES TWICE THE SIZE OF THE FIXTURE, BACKFILLED WITH PEA GRAVEL. EMBED (2) WELL LIGHTS IN CONCRETE. 7.CONTRACTOR SHALL LOCATE FIRST FIXTURE ON ALL RUNS A MINIMUM OF 25' FROM TRANSFORMER, OR ALLOW 25' OF CABLE SLACK BETWEEN FIXTURE AND TRANSFORMER. 8.FIXTURE LOCATIONS AND AIMING TO BE APPROVED IN THE FIELD BY LANDSCAPE DESIGNER. CONTRACTOR TO REVIEW FIXTURE NOTES ON PLAN PRIOR TO SITE VISIT BY LANDSCAPE DESIGNER. QTY NOTES / ACCESSORIES SYM FIXTURE: Vendor & Description Lamp LIGHTING LEGEND FX-ZD-RW-Path light-BW-3 LED-'Driveway' FX-ZD-TM-1 LED-BZ-Path Light T1 4 FX LUMINAIRE FX LUXOR ZD POWER CONTROLLER 300WATT 1 TRANSFORMER. Contactor to Locate placement Path Lights FX-ZD-LM-Wall Light-BZ-1 LED-Wall Light 8 Wall Lights Driveway Lights7606608610604602600 598 596 594 7% 8% 12% 11%12½% 10 %5885866126 1 4 11½%610(E ) 30 "OAK(E ) 35"OAK(E ) 32 "OAK(E ) 26 "OAK(E ) 24"OAK(E ) 8"OAK(E )10 "TREE612614(E )11 "OAK(E )16 "TREE(E ) 8 "OAK(E )10"OAK(E )14"TREE(E )10"PINE (E ) 6"ORNAM. (E ) 30"OAK(E )13 "OAK(E ) 25 "OAK(E ) 20"OAK(E )12 "OAK(E )GARDENS 81°59'00" E 119.50' (N )DRIVEWAY 578580590592588586584582594590592588586600 598 596 602 604606608610612 (N) RET. WALL(N) RET. WALL(N) RET. WALL(N )A/C (N )LOWERSTOOP(R )#19#38#37#36#35#33#34#31#32#16#15#6#5#4#7#8#9(N) 6' HIGH DEER FENCE(N) 6' HIGH DEER FENCE(E )D.G . (SAND )604.15T.O. CONC.603.65T.O. CONC.9½%10%10%5% MAX. (E ) D R I P L IN E ±(E) DRIPLINE ±F.P. 594. 0 0604.00F.P.604.40T.O. DECKT.O.W. 593.60B.O.W. 588.60592. 8 0 F.P. T.O. W . 593 . 0 0 B.O. W . 588 . 0 0 T .O .W . 5 8 8 . 5 0B.O .W . 5 8 3 . 0 0 T. O . W . 5 8 3 . 5 0 B. O . W . 5 8 2 . 0 0 T.O. W . 586. 8 0 B.O. W . 582. 7 0 T.O. W . 588. 2 5605.00F.P.B.O. W . 583. 7 0 T.O. W . 587. 0 0 B.O .W . 5 8 1 . 6 0B.O .W .592.00T.O .W .594.25 D P D D D D WW W W P P P P D W W W W T1 D PW P D W T1 93 TitleDrawing NumberCAD File NameDrawn ByDateFence and Entry Gate DN-06Jlb9.11.16TsaiTsai and Chow Residence20972 Saratoga Hills Rd Saratoga CA, 95070Designed ByJlbPhone: .408.218.8188NATURE LANDSCAPE DESIGN 650.222.0418 Deer Fence and Entry Gate Scale:1/8"=1'-0"6' High Deer Fence Automatic Iron Entry Gate Opener for Single Swing Gates 606608610604602600 598 596 594 7% 8% 12% 11%12½% 10 %5885867%6126 1 4 11½%590580600 610 600610(E ) 30 "OAK(E ) 35 "OAK(E ) 32 "OAK(E ) 26 "OAK(E ) 24 "OAK(E ) 8 "OAK(E )10 "TREE(E ) 8 "TREE(E )11"TREE(E )11 "OAK(E )12 "OAK598596594592602604606 608612614612 614 608 606 604 602 598 596 57 8 582584(E )11 "OAK(E )16 "TREE(E ) 8"OAK(E )10 "OAK(E )14 "TREE(E )10 "PINE (E ) 6 "ORNAM. (E ) 30 "OAK(E ) 24 "OAK(E )12 "PINE (E ) 28 "CYP. (E )18"CYP. (E ) 8 "TREE(E )TREEGROUP(E ) 20 "OAK(E )10 "OAK(E )11 "OAK(E ) 8 "TREE(E ) 7 "OAK(E ) 30 "OAK(E ) 8 "TREE(E )18 "OAK(E )11"OAK(E )12 "OAK(E )16"PINE (E )14 "OAK(E ) 32"OAK(E )16 "OAK(E ) 20 "OAK(E )18 "PINE (E )19"PINE (E )16"OAK(E )13 "OAK(E )14"OAK(E )10"OAK(E ) 20 "OAK(E )12"OAK(E )11"OAK(E ) 24 "OAK(E ) 25 "OAK(E ) 26 "OAK(E ) 28 "OAK(E ) 20 "OAK(E )12 "OAK(E )18"OAK(E ) 22 "OAK(E ) 23 "OAK(E ) 21 "OAK(E ) 22 "OAK(E )14"OAK(E )10 "OAK(E ) 7 "OAK(E ) 26 "OAK(E ) 7 "OAK(E )12 "ACACIA (E ) 24 "OAK(E ) 20 "OAK(E ) 6 "B-EYE (E ) 8 "B-EYE (E ) 8"ACACIAGROUP (E )11 "OAK(E ) SWALE (E ) INLET (E )BRIDGE (E )GARDEN(E ) INLET (E) SWALE (E) SWALE(E) SWALESARATOGAHILLSROADSARATOGAHILLSROADN 03°4 5' 2 1 " E 224.1 6'N 65°29'30" W 80.94'N 64°55'00" W 61.26'N 48°22'00" W36.99'N 43°56'00" W 66.50'N 32°10'00" W 93.47'S 47°41'00" E 83.77'S 81°59'00" E 119.50' (E ) 36 "OAK(E ) 24 "OAK(E ) BAYGROUP(E ) 25 "OAK(E )19"OAK(N )DRIVEWAY 578575578580590592588586584582594590592588586584582580600 598 596 594 592 590 588 586 584 582 580 578 602 604606608610612614 (N) RET. WALL(N) RET. WALL(N) RET. WALL(E) SWALE(N )A/C (N )LOWERSTOOP(R )#25#26#23#24#18#22#21#20#19#38#37#36#35#33#34#30#31#32#16#17#15#12#13#11#6#5#4#7#8#9#10#1#2#3(N) 6' HIGH DEER FENCE(N) 6' HIGH DEER FENCE(N) 6' HIGH DEER FENCE (N) 6' HIGH DEER FENCE(N) 6' HIGH DEER FENCE(E )D.G . (SAND )(E) SWALE575604.15T.O. CONC.603.65T.O. CONC.9½%10%10%5% MAX. LI N E ± ( E ) D R I P (E ) D R I P LI N E ±(E) DRIPLINE ±(E ) F IREHYDRANT(E )POLE(E )POLE(E )POSTGUY (E)(N)F.P. 594. 0 0604.00F.P.604.40T.O. DECKT.O.W. 593.60B.O.W. 588.60592. 8 0 F.P. T.O. W . 593 . 0 0 B.O. W . 588 . 0 0 T .O .W . 5 8 8 . 5 0B.O .W . 5 8 3 . 0 0 T. O . W . 58 3 . 5 0 B. O . W . 58 2 . 0 0 T.O. W . 586. 8 0 B.O. W . 582. 7 0 T.O. W . 588. 2 5605.00F.P.B.O. W . 583. 7 0 T.O. W . 587. 0 0 B.O .W . 5 8 1 . 6 0 T .O .W . 5 8 6 . 5 0 B.O .W .592.00T.O .W .594.25 T1 94 T1.0 1"=30' 95 T1.1 1"=20' 96