Loading...
HomeMy WebLinkAbout02-08-17 Planning Commission Agenda PacketSaratoga Planning Commission Agenda – Page 1 of 3 SARATOGA PLANNING COMMISSION REGULAR MEETING FEBRUARY 08, 2017 7:00 PM PLANNING COMMISSION REGULAR MEETING Civic Theater | 13777 Fruitvale Avenue, Saratoga CA 95070 PLEDGE OF ALLEGIANCE ROLL CALL APPROVAL OF MINUTES Action Minutes from the Regular Planning Commission Meeting of January 11, 2017. ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS Any member of the public will be allowed to address the Planning Commission for up to three (3) minutes on matters not on this agenda. This law generally prohibits the Planning Commission from discussing or taking action on such items. However, the Planning Commission may instruct staff accordingly regarding Oral Communications. REPORT ON APPEAL RIGHTS If you wish to appeal any decision on this Agenda, you may file an Appeal Application with the City Clerk within fifteen (15) calendar days of the date of the decision. 1. NEW BUSINESS 2. PUBLIC HEARING Applicants and/or their representatives have a total of ten (10) minutes maximum for opening statements. All interested persons may appear and be heard during this meeting regarding the items on this agenda. If items on this agenda are challenged in court, members of the public may be limited to raising only issues raised at the Public Hearing or in written correspondence delivered to the Planning Commission at, or prior to the close of the Public Hearing. Members of the public may comment on any item for up to three (3) minutes. Applicants and/or their representatives have a total of five (5) minutes maximum for closing statements. 2.1 Application PDR 16-0011 & ARB 16-0023; 14918 Three Oaks Court (397-18-098); Mike & Patti Workman – The applicant is requesting design review approval to construct a single story detached second unit. This application includes a 10% floor area increase request for deed restricted second units. Planning Commission Design Review approval is required because the total square footage of all structures on the property would exceed 6,000 sq. ft. A 24 inch Black Walnut Tree is proposed for removal. Staff contact: Sung H. Kwon (408) 868-1212 or skwon@saratoga.ca.us. Saratoga Planning Commission Agenda – Page 2 of 3 Recommended Action: Adopt Resolution No. 17-001 approving the project subject to recommended conditions of approval. Staff Report - 14918 Three Oaks Court Att 1 - Resolution of Approval Att 2 -Arborist Report dated October 31, 2016 Att 3 - Neighbor Notification Forms and Neighbor Comment Att 4 - Story Pole Certification Letter Att 5 - Existing Plans Att 6 - Proposed Plans 2.2 Application PDR16-0017 & ARB16-0035; 19421 San Marcos Road (397-13-017); Naga & Padmaja Kataru / ARCHevon, Inc. - The project applicant is requesting Design Review approval to construct a new 6,773 square foot two story single-family home which includes a 612 square foot attached secondary dwelling unit. Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 17-003 approving the project subject to conditions of approval included in Attachment 1. Staff Report-19421 San Marcos Rd Attachment 1 - Resolution of Approval for Design Review Attachment 2 - Arborist Report dated January 20, 2017 Attachment 3 - Neighbor Notification Forms Attachment 4 - Development Plans (Exhibit A) 2.3 Application PDR16-0028 & VAR16-0001; 14253 Worden Way (397-26-062); Rajat Monga & Sonu Durgia/ Rockwood Design Associates, Inc. - The applicant is requesting design review and variance approval to exceed the maximum allowable floor area. The existing residence has a floor area of 4,507 square feet and the project would add an additional 215 square feet for a total of 4,722 square feet. Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 17-004 approving the project subject to conditions of approval included in Attachment 1. Staff Report - 14253 Worden Way Attachment 1 - 1 Resolution of Denial of Variance Attachment 2 - 2 Neighbor Notification form Attachment 3 - Written Project Description (submitted by applicant) Attachment 4 - Easement Exhibit (submitted by applicant) Attachment 5 - Development Plans DIRECTOR ITEMS COMMISSION ITEMS Saratoga Planning Commission Agenda – Page 3 of 3 ADJOURNMENT CERTIFICATE OF POSTING OF THE AGENDA I, Janet Costa, Office Specialist III for the City of Saratoga, declare that the foregoing agenda for the meeting of the Planning Commission was posted and available for public review on February 2, 2017 at the City of Saratoga, 13777 Fruitvale Avenue, Saratoga, CA 95070 and on the City’s website at www.saratoga.ca.us. Signed this 2nd day of February 2017 at Saratoga, California. Janet Costa, Office Specialist III In Compliance with the Americans with Disabilities Act, if you need assistance to participate in this meeting, please contact the City Clerk at 408/868-1269. Notification 24 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility to this meeting. [28 CFR 35.102-35.104 ADA title II] You can also sign up to receive email notifications when Commission agendas and minutes have been added to the City at website http://www.saratoga.ca.us/contact/email_subscriptions.asp. NOTE: To view previous Planning Commission meetings anytime, go the City Video Archives at www.saratoga.ca.us REPORT TO THE PLANNING COMMISSION Meeting Date:February 8, 2017 Application:PDR 16-0011 & ARB 16-0023 Location / APN:14918 Three Oaks Court / 397-18-098 Owner / Applicant:Mike & Patti Workman/Louie Leu Staff Planner:Sung H. Kwon, Senior Planner 14918 Three Oaks Court 4 2 | P a g e SUMMARY Project Description:The applicant is requesting design review approval to construct a single story detached 600 sq. ft. second unit. This application includes the 10% floor area increase request for second units. A 24-inch Black Walnut tree is proposed for removal. The slope of the site is approximately 5.2%. Staff Recommendation:Adopt Resolution No. 17-001 approving the project subject to recommended conditions of approval. Planning Commission Design Review approval is required because the total square footage of structures would exceed 6,000 sq. ft. (Saratoga Municipal Code Section 15-45.060a(6).) Project Data: Site Area: 40,981sf net 56,427 sf gross Slope:5.2% Grading: 55 cy of cut, 0 cy of fil, 55 cy of export General Plan Designation: Residential Very Low Density (RVLD) Zoning:Single-Family Residential (R1-40,000) Proposed Allowed/Required Proposed Site Coverage House (N) Secondary Unit Driveway Pool, Patio, Walkways (N) Covered Patio (N) Pervious Concrete Walks Total Site Coverage Front Yard Impervious 5,966 sf 600 sf 2,125 sf 4,582 sf 806 233 sf 14,312 sf (35%) 0 sq. ft. (No change) 15,743 sf (38.5%) [14,312 sq. ft.(35%) + 10% 1,431 sq. ft. (10%) increase for a deed restricted secondary dwelling unit] Floor Area House Garage Enclosed Porch (N) Second Unit Total Floor Area 4,990 sf 878 sf 98 sf 600 sf 6,566 sf [6,020 sq. ft. + 10% (602 sq. ft.) increase for a deed restricted secondary dwelling unit] 6,622 sf Height of Main House (Existing)27 Feet 26 Feet Height of Second Unit Lowest Elevation Point: Highest Elevation Point: Average Elevation Point: Proposed Topmost Point: 535.50’ 536.80’ 536.15’ 552.00’ (15’ - 9”)26 Feet Setbacks of Main House (Existing) Front: Interior side: 43’ 54’ 30 ft. 20 ft. 5 3 | P a g e Exterior side: Rear: 30’ 48’ 25 ft. 20 ft. Setbacks of Second Unit Front: Interior side: Exterior side: Rear: 200’ 28’ 60’ 6” 20’ 30 ft. 20 ft. 25 ft. 20 ft. PROJECT DESCRIPTION/DISCUSSION Secondary Dwelling Unit: The 600 square foot, one story, 15’ – 9” feet tall secondary dwelling unit would be located to the east of the main residence. This one bedroom structure with a living room and full kitchen would have the same architectural style and exterior materials of the main residence. The secondary dwelling unit would be deed restricted. The Saratoga City Code allows a one-time ten percent increase in site coverage and allowable floor area if an applicant agrees to a deed restriction that would restrict the rental of a second unit to below market rate (BMR) households. A condition has been added to the project requiring this deed restriction be recorded prior to issuance of a building permit. The provision of the BMR second unit would allow the applicant to construct an additional 602 square feet of floor area on the site above the maximum allowable floor area of 6,020 square feet for a total allowable floor area of 6,622 square feet. The total proposed floor area for the entire site is 6,566 square feet. In addition, the 14,312 square foot (35%) maximum site coverage would also be increased by ten percent for a total allowed site coverage of 15,743 square feet. The total proposed site coverage is 14,312 square feet. Use of Secondary Unit: This application is only for a secondary dwelling unit. The applicant has not submitted a home occupation or business license request. Background:At the request of the applicant, the Planning Commission continued this project to a date uncertain on January 11, 2017. Thee next door neighbor (14870 Three Oaks Court) expressed concerns about the proximity of the second unit to their property and the covered patio. Staff facilitated conversations between the applicant and the next door neighbor to review potential options after the initial public hearing notices and erection of story poles but the adjacent neighbors’ concerns remain. Some of the items discussed by the applicant and the neighbor as part of these efforts include: Moving the second unit closer to the existing house. Removal of gable ends of the patio cover along the East and South Elevations. Provision of additional landscaping along the fence line to screen the second unit and/or the patio cover. 6 4 | P a g e Elimination of the patio cover. Moving the BBQ away from the neighbor. Relocation of the project to another side of the property. The applicant and the neighbor have also discussed with staff the Home Owner Association CCRs. These CCR’s are a civil matter and are independent of the Planning Commission Decision. Existing House:According to the plans for the existing house, the main house was built around 1990. No changes to the main house are proposed. Site & Neighborhood Description: The existing 5,966 square foot residence is located at 14918 Three Oaks Court. The residential neighborhood consists of a mix of single-storyand two-storyhouses with various architectural styles. Architectural Design:The existing house is of a contemporary style with traditional 6:12 sloping roof forms. The existing exterior materials include stucco, stucco quoins, wood shutters, and a wood shake roof. Precast concrete windows sills are provided under the larger prominent windows facing the street. The proposed second unit mirrors the contemporary architecture with stucco quoins and wood shake roof. The double door entryway of the second unit matches the entry to the main house. The applicant has provided a color and materials board, which is on file with the Community Development Department and available for review. Below is a list of the proposed exterior materials. Landscaping:A 24-inch (dbh) Walnut tree (protected tree) is proposed for removal. The City Arborist noted that the removal of the tree meets the criteria for removal because it is conflict with the proposed covered patio. A 4-inch (dbh) tree (non-protected) located in the front of the proposed second unit will also be removed. In addition to the existing trees located along the South and East property lines, two Japanese Maple trees are proposed along the rear (East property line) and two Japanese Maple trees are proposed along the interior side (South property line) of the property. A Live Oak tree is also proposed in the front yard (West property line). Detail Colors and Materials Exterior Grey Doors White Windows White Trim White Wood Fascia Roof Brown Wood Shingle 7 5 | P a g e The two new trees along the East property line will provide additional screening of the second unit from the neighboring residence. CalGreen Standards/Sustainable Features: The project as submitted, proposes to comply with the required CalGreen standards. Neighbor Notification and Correspondence: The applicant submitted neighbor notification forms. Public notices were sent to property owners within 500 feet of the site. The Neighbor at 14870 Three Oaks Court has provided comments. In addition, the applicant has provided letters of support for the proposed project. See Attachment 3. The applicant provides support letters from 6 neighbors. The neighbor at 14870 Three Oaks Court expressed concerns about: 1) Height, mass, privacy, 2) views, 3) Noise and Privacy, 4) Protected Trees. This neighbor proposes relocation of the project or to move the second unit as close to the garage as possible and the elimination of the covered patio. DESIGNREVIEWFINDINGS The findings required for issuance of a Design Review Approval pursuant to City Code Section 15-45.080 are set forth below and the applicant has met the burden of proof to support making all of those required findings: (a)Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property's natural constraints.The project meets this finding because the second unit is located on a relatively flat lot. The amount of grading is minimal. (b)All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080.The neighbor at 14870 Three Oaks Court has expressed concerns about the removal of the protected tree. The Arborist Report notes that the 24-inch Black Walnut tree is in conflict with the proposed patio cover and therefore meets the criteria for removal. As such, the project meets this finding. (c)The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds.The neighbor at 14870 Three Oaks Court has expressed concerns about noise and privacy. The City of Saratoga currently has noise regulations that apply to all residential uses. 8 6 | P a g e 7-30.040 - Noise standards Daytime (7:00 am to 7:00 pm) Evening (7:00 pm to 10:00 pm) Nighttime (10:00 pm to 7:00 am) Average L eq Maximum L max Average L eq Maximum L max Average L eq Maximum L max Residential (single & multi-family)55 65 45 55 40 50 All residential property owners would have to abide by the noise ordinance regardless of whether there is a covered patio or not. Having a covered patio would not necessarily create noise impacts. In terms of privacy, the residential design guidelines focus mostly on window privacy toward other windows and enclosed yards. The second unit is one story with a maximum height of 15 feet 9 inches. The East facade includes two windows (a bathroom window and a kitchen window) that face the adjacent neighbor’s garage and driveway. Existing landscaping and two proposed trees would partially screen the second unit from the neighboring residence. The proposed covered patio is screened from the neighbor’s back yard by an existing 6 foot high wood fence. The proposed project is not located on top of a ridgeline and thus would not impact a community viewshed. The project meets this finding as privacy impacts are limited and a community viewshed would not be impacted. (d)The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood.The neighbor at 14870 Three Oaks Court has expressed concerns about height and massing. The project meets this finding because the second unit incorporates design elements are in scale with the main house. There are a number of two story homes in the neighborhood including the house across the street. The proposed second unit is single story with a height of 15 feet 9 inches. The eave line of the second unit matches the eave line of the existing house. In addition the roof slope of the second unit is 5:12 which is lower but similar to the slope of the roof the main residence at 6:12. These design elements limit the height of the second unit. The second unit will include similar materials and exterior finishes of the existing house including grey plaster, quoins on edges of the structure, wood shingle roof, and white wood facia under the eaves. These architectural elements assist in keeping the structure in scale with the main house and the neighboring residences. (e)The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape.The project meets this finding because front yard landscape will remain intact and unharmed throughout the life of the project. The proposed project would be completed completely outside of the front setback area. 9 7 | P a g e (f)Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. The project meets this finding because, due to the location and single story height of the second unit and covered patio, the development will not unreasonably impair the ability of adjoining properties to utilize solar energy. (g)The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055.The project meets this finding because the project has managed mass through appropriate building design rather than landscaping, minimized the use of excessive colors and materials, and maintained the generally established exterior corner side yard setbacks along the street. The protected tree proposed for removal would not impact privacy due to its location. In terms of location, the second unit would be approximately 60 feet from the adjacent structure. The neighbor at 14870 Three Oaks Court has expressed concerns about views. The zoning code and the residential design guidelines do not include view protection standards. (h)On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100.The project is not applicable as it is not on a hillside lot. Environmental Determination:The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction or conversion of up to three single-family residences. Attachments: 1. Resolution of Approval 2. Arborist Report dated October 31, 2016 3. Neighbor Notification Forms and Neighbor Comments 4. Story Pole Certification Letter 5. Existing Plans 6. Proposed Plans 10 1 RESOLUTION NO: 17-001 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR 16-0011 & ARB 16-0023 LOCATED AT 14918 THREE OAKS COURT WHEREAS, on June 15, 2016, an application was submitted by Louie Leu requesting Design Review approval to construct a single story detached 600 sq. ft. second unit and related site improvements located at 14918 Three Oaks Court. The height of the proposed second unit is approximately 16.35 feet. The site is located within the R-1-40,000 Zoning District (APN: 397-18- 098). WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA), and recommends that the Planning Commission determine this project exempt. WHEREAS, on January 11, 2017, the Planning Commission continued this project to a date uncertain at the request of the applicant. WHEREAS, on February 8, 2017, the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of a second dwelling unit in a residential area. Section 3: The project is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The project is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings in that the project follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints; preserves protected trees; is designed to avoid unreasonable impacts to the privacy of adjoining Attachment 1 11 2 properties and to community viewsheds; the mass and height of the structure and its architectural elements are in scale with the structure itself and with the neighborhood; landscaping minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape; does not unreasonably impair the ability of adjoining properties to utilize solar energy; and is consistent with the Residential Design Review Handbook. Section 5: The City of Saratoga Planning Commission hereby approves PDR16-0011 & ARB 16-0023 located at 14918 Three Oaks Court, subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 8th day of February 2017 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ DeDe Smullen Chair, Planning Commission 12 3 Exhibit 1 CONDITIONS OF APPROVAL PDR 16-0011 & ARB 16-0023 14918 THREE OAKS COURT (APN: 397-18-098) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. 13 4 COMMUNITY DEVELOPMENT 5. Site Drainage. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 6. Construction must be commenced within 36 months from the date of this approval (January 11, 2019), or this resolution will expire. 7. Compliance with Plans. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Plans denominated Exhibit "A" dated January 30, 2017. All proposed changes to the Approved Plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 8. Lighting. Exterior lighting shall be shielded so as not to shine on adjacent properties or public right-of-way. 9. Maintenance of Construction Project Sites. Because this Design Review Approval authorizes a project which requires a Building Permit, compliance with City Code Section 16- 75.050 governing maintenance of construction project sites is required. 10. Construction Management Plan. Prior to Building Permit issuance the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 11. Fences, Walls and Hedges. All fences, walls and hedges not in connection with the proposed fence exception shall conform to height requirements provided in City Code Section 15-29. 12. Final Landscaping and Irrigation Plan. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall take into account the following: 14 5 a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency and plant interactions to ensure successful establishment. d. Any proposed or required under grounding of utilities shall take into account potential damage to roots of protected trees. 13. Noise and Construction Hours. In order to comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 14. Building Division Submittal. Four (4) sets of complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. d. The site plan shall contain a note with the following language: “Prior to foundation inspection by the City, the Licensed Land Surveyor of record shall provide a written certification that all building setbacks comply with the Approved Plans,” which note shall represent a condition which must be satisfied to remain in compliance with this Design Review Approval. 15. Deed Restriction. The owner shall restrict the rental of the second unit to only households that qualify as low, very-low, or extremely-low income households as those terms are defined in the most recent Santa Clara County Housing and Urban Development Program Income Limits or, in the event that the most recent such report is more than five years old, in accordance with the definitions set forth in Health and Safety Code section 50079.5, 50105, and 50106 as those sections exist as of the effective date of this restriction. “Rental” means any agreement whereby the occupant(s) of the second unit make any payment in consideration of said occupancy. This restriction shall be recorded prior to final inspection. ARBORIST 16. Arborist Report. All requirements in the City Arborist Report dated October 31, 2016 are hereby adopted as conditions of approval and shall be implemented as part of the approved plans. 15 6 PUBLIC WORKS 17. Applicant/Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including but not limited to approach/apron and driveway prior to commencement of the work. 18. Site Grading plan are adequate as indicated on Sheet 1 and Sheet 2 of 2. Plan shall be stamped by Westfall Engineers. 19. Applicant/Owner shall implement a construction site inspection and control program to prevent construction site discharges of pollutants into the storm drains. Provide perimeter silt fences and straw wattles around the new addition during construction at all times as redlined on the Civil Plans 2 of 2. 20. Provide/show utilities (including gas, electricity, and etc.) to new addition. All utilities shall be grounded. 21. Prior to final, area drain, bubbler and site grading shall be completed. FIRE DEPARTMENT 22. Review of this Developmental proposal is limited to acceptability of site access and water supply as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 23. Fire Sprinklers Required: An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings as follows: In all new one- and two-family dwellings and in existing one- and two-family dwellings when additions are made that increase the building area to more than 3,600 square feet. Exception: A one-time addition to an existing building that does not total more than 1,000 square feet of building area. NOTE: The owner(s), occupant(s) and any contractor(s) or subcontractor(s) are responsible for consulting with the water purveyor of record in order to determine if any modification or upgrade of the existing water service is required. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. CRC Sec. 313.2 as adopted and amended by SMC. 24. Water Supply Requirements: Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be 16 7 granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2010 CFC Sec. 903.3.5 and Health and Safety Code 13114.7. 25. Construction Site Fire Safety: All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification SI-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chp. 33. 26. Address identification. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained. CFC Sec. 505.1. ****************** END OF CONDITIONS OF APPROVAL ****************** 17 Community Development Department City of Saratoga 13777 Fruitvale Avenue Saratoga, California 95070 ARBORIST REPORT Application No. ARB16-0004 Prepared by Kate Bear, City Arborist Site: 14918 Three Oaks Way Phone: (408) 868-1276 Owner: Mike and Patti Workman Email: kbear@saratoga.ca.us APN: 397-18-098 Email:pattiko57@gmail.com Report History: Final report Date:October 31, 2016 PROJECT SCOPE: The applicant has submitted plans to build a second unit. One black walnut tree is requested for removal to construct the project. STATUS: Approved by City Arborist, with attached conditions. PROJECT DATA IN BRIEF: Tree bond – Required - $38,470 For trees 1 – 9 Tree fencing – Required – See Conditions of Approval and Site Plan. Tree removals – Tree 1 is approved for removal and replacement once building permits have been issued. Replacement trees – Required = $8,000 ATTACHMENTS: 1 – Findings 2 – Tree Removal Criteria 3 – Tree Information 4 – Map Showing Tree Protection 5 – Conditions of Approval Attachment 2 18 14918 Three Oaks Court Attachment 1 FINDINGS: Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. One California black walnut, tree 1, is in conflict with the covered patio, and meets the City’s criteria allowing it to be removed and replaced as part of the project, once building division permits have been obtained. Attachment 2 contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No. Criteria met 1 1, 4, 7, 9 New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15- 50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1) The Recommendations, Project Map (Appendix 1), and Tree Table (Appendix 2) from the submitted arborist report dated October 10, 2016; 2) The Project Data in Brief and the Conditions of Approval from this report dated October 31, 2016. 19 14918 Three Oaks Court Attachment 2 TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2) The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. (3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. (4) The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. (5) The age and number of healthy trees the property is able to support according to good forestry practices. (6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7) Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8) Any other information relevant to the public health, safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9) The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. (10) The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. 20 14918 Three Oaks Court Attachment 3 TREE INFORMATION: Arborist Report reviewed: Preparer: Katherine Naegele, Anderson Tree Care Specialists, Inc. Date of Report: October 10, 2016 An arborist report was submitted for this project that inventoried nine trees protected by Saratoga City Code. Information on the condition of each tree, potential impacts from construction, suitability for preservation, appraised values and tree protection recommendations was provided. Appendix 2 from the submitted report is below. One black walnut (tree 1) protected by Saratoga City Code is requested for removal to construct this project. 21 Attachment 4 14918 Three Oaks Court Legend Tree Canopy Tree Protection Fencing 1 6 5 7 3 4 2 8 9 22 14918 Three Oaks Court Attachment 5 CONDITIONS OF APPROVAL 1. It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2. All recommendations in the arborist report dated October 10, 2016 prepared by Katherine Naegele shall become conditions of approval. 3. The recommendations, list of trees and map from the arborist report dated October 10, 2016 shall be copied on to a plan sheet, titled “Tree Preservation” and included in the final job copy set of plans. 4. The Project Data in Brief and Conditions of Approval from this report dated October 31, 2016, shall be included in the final set of plans. 5. The designated Project Arborist shall be Katherine Naegele, unless otherwise approved by the City Arborist. 6. Tree Protection Security Deposit a. Is required per City Ordinance 15-50.080. b. Shall $38,470 be for tree(s) 1 – 9. c. Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d. May be in the form of cash, check, credit card payment or a bond. e. Shall remain in place for the duration of construction of the project. f. May be released once the project has been completed, inspected and approved by the City Arborist. 7. Tree Protection Fencing: a. Shall be installed as shown on the attached map. b. Shall be shown on the Site Plan. c. Shall be established prior to the arrival of construction equipment or materials on site. d. Shall be comprised of six-foot high chain link fencing mounted on eight-foot tall, 2-inch diameter galvanized posts, driven 24 inches into the ground and spaced no more than 10 feet apart. e. Shall be posted with signs saying “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, KATE BEAR (408) 868-1276”. f. Call City Arborist, Kate Bear at (408) 868-1276 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. g. Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 8. If contractor feels that work must be done inside the fenced area, call City Arborist to arrange a field meeting before performing work. 23 14918 Three Oaks Court Attachment 5 9. The Project Arborist shall visit the site every eight weeks during construction. Following visits to the site, the Project Arborist shall provide the City with a report including photos documenting the progress of the project and noting any tree issues. 10. No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 11. Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. 12. All construction activities shall be conducted outside tree protection fencing. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 13. Trenching to install utilities is not permitted inside tree protection fencing. 14. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. Roots measuring less than two inches in diameter may be cut using a sharp pruning tool. 15. Any permitted pruning or root pruning of trees on site shall be performed under the supervision of the Project Arborist and according to ISA standards. 16. Tree 1 meets the criteria for removal and may be removed and replaced once Building Division permits have been obtained. 17. Trees permitted for removal shall be replaced on or off site according to good forestry practices, and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. The value of the removed trees shall be calculated in accordance with the ISA Guide for Plant Appraisal. 18. New trees equal to $8,000 shall be planted as part of the project before final inspection and occupancy of the new home. 19. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 20. New trees may be of any species. 21. Should any tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant new trees, some or all of the replacement value for trees shall be paid into the City’s Tree Fund. 24 14918 Three Oaks Court Attachment 5 22. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 23. Following completion of the work around trees, and before a final inspection of the project, the applicant shall provide a letter to the City from the Project Arborist. That letter shall document the work performed around trees, include photos of the work in progress, and provide information on the condition of the trees. 24. At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call City Arborist for a final inspection. 25 Attachment 3 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Attachment for planning commission. Subject: 14918 Three Oaks Court Saratoga, Workman Secondary Dwelling – Tract 8100 HOA Approval HOA CC&R’s: 7 Lot Owners. 5/7 vote “for” constitutes approval of a proposal to build on the property, we have 6/7 “for” votes, and one we believe is against. But we exceed the required 5. So in summary then we have the following votes for Tract 8100 HOA: Lot Owner For Against Notes Ngyuen  Guercio  Langoulant  Gong  McCaskey  Workman  Paisley  Not sure of this vote. Total 6 1 6 of 7: Approved The CC&R’s require a vote of 5 out of the 7 homeowners to carry approval. We have exceed the votes required by at least 1 for this project. There is an ACC – Architectural Control Committee of three reps from 3 lots. The HOA level vote overrides the ACC by the Tract 8100 CC&R’s – although in this case a majority of the ACC have approved the project as well (2/3). Here are the approval emails from the 5 homeowners in addition to ourselves: 1. Kevin (Jiantang) Gong. Referred to as a pool house as it is similar to the one he has on his Three Oaks Ct Property – which they refer to as a “pool house”. 41 The plans included this mock up from Louie Lue: 2. David Guercio I apologize for the small print. Regarding the Secondary Dwelling (Dave has one as well), he writes (item 3 above): “By all means I can give you my thoughts and plans…frankly, I will agree with any version that you want…it is your property and I am confident that you will go with something that looks good and ties to your home’s design.” [Ellipses are his]. 42 Helen Ngyuen: “Sure, we do not have any problem with your new building. Please go ahead. “ 3. Brendan Langoulant: His note says “Approved”. The images they reviewed include: 43 44 North Elevation – View from the street (Three Oaks Ct). East Elevation – view looking toward Highway 9 from inside Workman’s backyard. 5.5 foot high fence and trees will cover most of this view (but are not shown). South Elevation – View from back of Workman’s Lot – Trees, shrubs and Tract 8100 fence will hide most of this from neighbors view. West Elevation – View from Workman’s backyard – Pool area. Half of this will be obscured from view by the rest of the house. The only people that can see this are the Workman’s. 45 Placement of the building (bright green) and covered patio (yellow) on the lot: 4. Char McCaskey: Her email which contained the above plans, drawings and elevations says: Hi Patti, I just returned home tonight. Yes I approve your planned structure. Char 46 Char McCaskey’s email: 47 Attachment 4 48 49 50 51 52 53 54 55 56 57 58 59 REPORT TO THE PLANNING COMMISSION Meeting Date: February 8, 2017 Application: PDR16-0017, ARB16-0035 Location / APN: 19421 San Marcos Road / 397-13-017 Owner/Applicant: Naga & Padmaja Kataru / ARCHevon, Inc. Staff Planner: Christopher Riordan 19421 San Marcos Road SITE 60 Page 2 of 7 Summary PROJECT DESCRIPTION: The applicant is requesting Design Review approval to construct a new 6,773 square foot two-story single-family home which includes a 612 square foot attached secondary dwelling unit. The City Arborist has made the required findings for the removal of nine protected trees. The net lot size area is 48,007 square feet and is zoned R-1-40,000. STAFF RECOMMENDATION: Adopt Resolution No. 17-003 approving the project subject to conditions of approval. Design Review Approval by the Planning Commission is required pursuant to City Code Section 15-45.060(a)(3). PROJECT DATA: Gross/Net Site Area: 48,007 SF Average Site Slope: 3.4% General Plan Designation: RVLD (Very Low Density Residential) Zoning: R-1-40,000 Grading: 675 cubic yards (425 cut and 250 fill) Data Proposed Allowed/Required Conformance Site Coverage Residential Footprint Covered Porches Walks/Decks/Patios Permeable Surfaces Total Proposed Site Coverage 3,877 sq. ft. 2,278 sq. ft. 2,323 sq. ft. 3,104 sq. ft. 11,582 sq. ft. (24.1%) 18,482 sq. ft. [16,802 sq. ft. + 10% (1,680 sq. ft.) increase for a deed restricted secondary dwelling unit] Conforms Floor Area Main House First Floor / Secondary Unit Second Story Garage Total Floor Area 3,363 sq. ft. 2,896 sq. ft. 514 sq. ft. 6,773 sq. ft. 6,798 sq. ft. [6,180 sq. ft. + 10% (618 sq. ft.) increase for a deed restricted secondary dwelling unit] Conforms Height (Residence) Lowest Elevation Point: Highest Elevation Point: Average Elevation Point: Proposed Topmost Point: Total Proposed Height 98.50 101.00 99.75 125.50 (25.75 ft.) 26 Feet Conforms Setbacks Front Left (First Floor) Left (Second Floor) Right (First Floor) Right (Second Floor) Rear (First Floor) Rear (Second Floor) 70’-7” 60’-7” 60’-7” 82’-11” 90’-10” 68’-9” 73”-4” 30’ 20’ 25’ 20’ 25’ 50’ 60’ Conforms 61 Page 3 of 7 PROJECT DESCRIPTION AND SITE CHARACTERISTICS Site Background: The 48,007 square foot site is located at 19421 San Marcos Road. The average site slope is 3.4% with a grade change of five feet from the southeast corner to its northeast corner. Surrounding uses include a driveway, parking lot and tennis courts of West Valley College to the north and single-family ranch style homes on the remaining three sides located on sites of similar size as the subject site. Site access is provided by a private driveway that connects to San Marcos Road. A combination of wood and chain link fencing surrounds the project site. Existing mature landscaping screens the site from adjacent properties and the site is not visible from any public streets. Currently located on the site are an existing 3,260 square foot one-story single-family home and an 888 square foot detached garage. An existing swimming pool and equipment shed are located to the south of the existing residence. An additional shed is located to the south of the swimming pool. A putting green is located near the front of the driveway. All existing structures are proposed to be demolished. A total of 38 protected trees would be potentially impacted by the project. These include Coast live oaks, Coast redwoods, California black walnut, and Mexican fan palms. All trees are in fair or good condition with the exception of two Black walnuts in poor condition. On November 12, 2014, the Planning Commission reviewed and approved a Design Review application (Resolution No. 14-051) for the site to construct a 5,187 square foot two story-single family residence and a 817 square foot detached secondary dwelling unit. The project included a 1,172 square foot basement. This approved project had a Mediterranean influenced design with a wide asymmetrical building footprint with the second story centered in the center of the building footprint with one story projections on opposite sides. Exterior materials included smooth stucco, stone columns, wrought iron railings, and copper gutters and downspouts. Elevations of the approved design are located on Sheet A8.0 (Comparative Analysis) of the proposed Development Plans (Attachment #4). A building permit for the project was applied for but not issued and subsequently there was a transfer of site ownership. The current owners submitted a new Design Review application which includes revised architectural plans with a completely different design than that was approved. This new proposal is described in the following paragraphs. Project Description and Architectural Style: The project would include the construction of a two-story single-family main residence which includes an attached secondary dwelling unit. The 6,259 square feet main residence would be 25.75’ feet tall with a 514 square foot attached garage. The proposed residence would have a “Contemporary” architectural style. Contemporary homes are characterized by open floor plans with minimal doors and walls with an emphasis on a direct connection between indoors and outdoors. Architectural features often include movable exterior walls with access to outdoor “rooms” with fireplaces and fully equipped outdoor kitchens and barbecues. Almost all Contemporary houses share common design elements such as tall, often irregularly shaped windows; bold geometric shapes; and asymmetrical façades and floor plans. 62 Page 4 of 7 The proposed materials and architectural forms to support the “Contemporary” style include geometric wall planes with simple massing lacking superfluous architectural detailing. Exterior finishes would include a stucco exterior, tile cladding at the front entrance and columns of the lower level loggia at the rear of the building, glass guardrails at the second story balconies, square shaped windows with aluminum frames, and a metal roof with both flat and hipped roof forms. No fireplaces are proposed. Secondary Dwelling Unit: The 612 square foot one bedroom attached secondary dwelling unit would be located on the first story. The secondary dwelling unit would be deed restricted. The Saratoga City Code allows a one-time ten percent increase in site coverage and allowable floor area if an applicant agrees to a deed restriction restricting the rental of a second unit to below market rate (BMR) households. A condition has been added to the project requiring this deed restriction be recorded prior to issuance of a building permit. The provision of the BMR second unit would allow the applicant to construct an additional 618 square feet of floor area on the site above the maximum allowable floor area of 6,180 square feet for a total allowable floor area of 6,798 square feet. The total proposed floor area for the entire site is 6,773 square feet. In addition, the 16,802 square foot (35%) maximum site coverage would also be increased by ten percent for total allowed site coverage of 18,482 square feet. The total proposed site coverage is 11,582 square feet. Projects with secondary dwelling units are required to provide parking for one vehicle within an enclosed garage that is in addition to the required parking for the main residence. The enclosed parking requirement for the second dwelling unit can be waived if it is deed restricted. A carport for one vehicle would be constructed adjacent to the two car garage. Landscaping: The proposed landscape plan (pages L1 – L10 of the Development Plans) illustrates that the project will feature drought resistant flowering plants, groundcover, and grasses. The driveway would be composed of permeable pavers. The outdoor entertainment area located at the rear of the residence would feature an outdoor bar, bbq area, and a sunken outdoor gas fire pit with seating. Materials and Colors: Detail Colors and Materials Exterior Two-tone tan colored stucco Windows Aluminum Deck Guardrails Glass Garage Door Off white colored metal door Roof Tan colored metal Trees: A total of 38 protected trees potentially impacted by the project were reviewed by the City Arborist. These include Coast live oaks, Coast redwoods, California black walnut, and Mexican fan palms. All trees are in fair or good condition with the exception of two Black walnut trees in poor condition. 63 Page 5 of 7 Nine of the protected trees are requested for removal to construct the project. These include four Mexican fan palms, two black walnuts, two crape myrtles, and one Hollywood juniper. The City Arborist has determined that all the trees proposed for removal meet the criteria allowing removal and replacement as listed in the arborist report. Remaining protected trees in the vicinity of the project will be protected during its duration. Details of the arborist findings and descriptions of the tree to be removed are included in the Arborist report which is included as Attachment #2. Neighbor Notification and Correspondence: The applicant submitted two (2) Neighbor Notification Forms signed by adjacent property owners. None of the forms included negative comments related to the project. Copies of the neighbor notification forms are included as Attachment #3. The adjacent neighbor to the south at 19431 San Marcos Road met with staff during review of the previously approved project to express their concerns related to possible construction related impacts to the shared common driveway. To ensure maintenance of the driveway, staff is continuing to recommend a condition of approval that the applicant videotape the surface of the shared driveway prior to the start of construction and would be required to make any construction related repairs prior to building permit final. A Public Notice was also sent to property owners within 500 feet of the site. No additional concerns have been brought to the City’s attention as of the writing of this staff report. FINDINGS Design Review Findings - The Planning Commission shall not grant design review approval unless it is able to make the following findings. These findings are in addition to and not a substitute for compliance with all other Zoning Regulations (which constitute the minimum requirements, as provided in City Code Section 15-05.050). 1. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative because the proposed development and grading are located in a predominantly level area and is concentrated towards the center of the site thereby preserving the sites existing contours. Grading for the site will be primarily limited to constructing the building pad and site landscaping and contouring the site to direct drainage to landscaped areas and detention facilities. 2. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in go od health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the project has been designed to reduce impacts to a minimum number of protected trees. The 38 trees that were inventoried as being potentially impacted include 64 Page 6 of 7 Coast live oaks, Coast redwoods, California black walnut, and Mexican fan palms. The City Arborist has determined that all the trees proposed for removal meet the criteria allowing removal and replacement as listed in the arborist report. The remaining protected trees in the vicinity of the project will be preserved and protected during the duration of the project. 3. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the 1.1 acre size of the parcel, the distance from the subject project to adjacent structures, and existing and proposed vegetation and trees would screen views from adjacent properties. Privacy impacts associated with the second story balconies would be reduced by the distance of the front setback and existing and proposed landscaping along the southern and western property lines. The project would not impact any identified community viewsheds. 4. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the overall design, height, materials, and location of building will avoid the perception of excessive bulk and the Contemporary architectural theme of the project and the use of architecturally true elements helps unify the building façades. The facades of the buildings are well articulated with jogs in the building lines with varying height of roof elements, architectural projections, and rooflines. The views from homes on adjacent sites are screened by existing and proposed landscaping. 5. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the hardscape for driveway in the front setback area is limited to 13% of the 6,260 square feet front setback area. The remaining area of the front setback composing 87% of the area will be landscaped with flowering plants and trees. 6. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the location of the nearest existing residence is located at a distance of more than 100 feet and that all proposed landscaping would be located in close proximity to the development so there would be no shadowing that could impair the ability of adjoining properties to utilize solar energy. Mature trees surround the development but because adjacent properties are of similar square footage and have large setbacks there would not be an unreasonable impact on adjoining properties. 7. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk, and avoiding unreasonable interference with privacy and views as detailed in the findings above. 8. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance 65 Page 7 of 7 with Section 15-13.100. This finding is not applicable to the project as the site is not classified as a hillside lot. Environmental Determination: The project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New Construction or Conversion of Small Structures”, of the Public Resources Code (CEQA). This exemption allows for the construction of up to three single-family residences and no exception to that exemption applies. STAFF RECOMMENDATION: Adopt Resolution No. 17-003 approving the project subject to conditions of approval. ATTACHMENTS: 1. Resolution of Approval for Design Review 2. Arborist Report dated January 20, 2017 3. Neighbor Notification Forms 4. Development Plans (Exhibit A) 66 RESOLUTION NO: 17-003 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING A NEW TWO STORY SINGLE FAMILY RESIDENCE LOCATED AT 19421 SAN MARCOS ROAD WHEREAS, on August 3, 2016, an application was submitted by ARCHevon, Inc. on behalf of Naga & Padmaja Kataru requesting Design Review approval to construct a new two story home located at 19421 San Marcos Road. The project has a total floor area of 6,773 square feet. The height of the proposed residence would be 25.75 feet. The site is located within the R-1-40,000 zoning district (APN 397-13-017). WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA), and recommends that the Planning Commission determine this project exempt. WHEREAS, on February 8, 2017, the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New Construction or Conversion of Small Structures”, of the Public Resources Code (CEQA). This exemption allows for the construction of up to three single-family residences and no exception to that exemption applies. Section 3: The project is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; Land Use Element Goal 10 which minimizes the impact of development proposals in hillside areas by requiring visual analyses and imposition of conditions to prevent or reduce significant visual impacts; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The project is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings in that the project follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints; preserves protected trees; is designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds; the mass and height of the structure and its architectural elements are in scale with the structure itself and with the neighborhood; landscaping minimizes Attachment 1 67 hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape; does not unreasonably impair the ability of adjoining properties to utilize solar energy; is consistent with the Residential Design Review Handbook; and in the case of hillside lots, avoids unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13-100. Section 5: The project is consistent with the Saratoga City Code in that the removal of nine protected tree meets the criteria established in Section 15-50.080(a). Section 6: The City of Saratoga Planning Commission hereby approves PDR16-0017 and ARB16-0035 located at 19421 San Marcos Road subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 8th day of February 2017 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ DeDe Smullen Chair, Planning Commission 68 Exhibit 1 CONDITIONS OF APPROVAL PDR16-0017 and ARB16-0035 19421 San Marcos Road (APN 397-13-017) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. 5. Construction must be commenced within 36 months from the date of this approval (February 8 11, 2020), or this resolution will expire. 69 COMMUNITY DEVELOPMENT 6. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 7. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Plans dated November 23, 2016. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 8. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full-cut off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 9. In order to comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 10. Prior to issuance of Building Permits the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 11. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. The proposed solid property line fence shall not exceed a height of 6’ with 2’ of lattice. 12. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall take into account the following: 70 a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall take into account potential damage to roots of protected trees 13. This Condition is Permanent: The owner shall record a deed restriction satisfactory to the Community Development Director restricting the rental of the second unit to only households that qualify as low, very-low, or extremely-low income households as those terms are defined in the most recent Santa Clara County Housing and Urban Development Program Income Limits. In the event that the most recent such report is more than five years old, in accordance with the definitions set forth in Health and Safety Code section 50079.5, 50105, and 50106 as those sections exist as of the effective date of this restriction. “Rental” means any agreement whereby the occupant(s) of the second unit make any payment in consideration of said occupancy. 14. Prior to building permit issuance, the applicant shall videotape the surface of the shared driveway that provides access from the site to San Marcos Road. A copy of the tape shall be retained by the Community Development Department. Any damage to the shared driveway caused by project related construction shall be repaired by the applicant prior to building permit final. ARBORIST 15. All requirements in the City Arborist Report dated January 20, 2017 are hereby adopted as conditions of approval and shall be implemented as part of the approved plans. PUBLIC WORKS 16. Applicant (owner) shall obtain an encroachment permit from the City for any and all improvements in any City right-of-way or City easement prior to commencement of the work to implement this Design Review. 17. Prior to issuance of Zoning approval, the applicant shall submit a site plan and associated calculations for stormwater treatment measures in compliance with NPDES Permit No. CAS612008, November 19, 2015 Provision C.3.i. Required Site Design Measures for Small Projects and Detached Single-Family Home Projects. 71 FIRE DEPARTMENT 18. The owner/applicant shall comply with all Fire Department requirements. BUILDING DEPARTMENT SUBMITTAL 19. Four (4) sets of complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. d. The site plan shall contain a note with the following language: “Prior to foundation inspection by the City, the Licensed Land Surveyor of record shall provide a written certification that all building setbacks and elevations comply with the Approved Plans,” which note shall represent a condition which must be satisfied to remain in compliance with this Design Review Approval. 72 Community Development Department City of Saratoga 13777 Fruitvale Avenue Saratoga, California 95070 ARBORIST REPORT Application No. ARB16-0038 Prepared by Kate Bear, City Arborist Site: 19421 San Marcos Road Phone: (408) 868-1276 Owner: Naga Kataru Email: kbear@saratoga.ca.us APN: 397-13-017 Email: kataru@stanford.edu Report History: Final report Date: January 20, 2017 PROJECT SCOPE: The applicant has submitted plans to demolish the existing house and build a new two stor y house with an attached two-car garage. Nine trees (332, 335, 337, 338, 340, 341, 343, 349 and 356) protected by Saratoga Cit y Code are requested for removal to construct the project. They consist of 4 palms, 2 black walnuts, 2 crape myrtles and 1 juniper. STATUS: Approved by City Arborist, with attached conditions. PROJECT DATA IN BRIEF: Tree bond – Required - $49,770 Tree fencing – Required – See Conditions of Approval and attached map. Tree removals – Trees 332, 335, 337, 338, 340, 341, 343, 349 and 356 are approved for removal once building permits have been issued. Replacement trees – Required = $7,590 ATTACHMENTS: 1 – Findings 2 – Tree Removal Criteria 3 – Tree Information 4 – Conditions of Approval 5 – Map Showing Tree Protection 1 73 19421 San Marcos Road Attachment 1 FINDINGS: Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. Nine trees (332, 335, 337, 338, 340, 341, 343, 349 and 356) protected by the City Code meet the City’s criteria allowing them to be removed and replaced as part of the project, once building division permits have been obtained. Attachment 2 contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No. Species Criteria met 332 Hollywood juniper 1, 4, 6, 7, 9 335, 337, 338, 343 Mexican fan palms 1, 4, 6, 7, 9 340, 341, Crape myrtles 1, 4, 6, 7, 9 349, 356 Black walnuts 1, 4, 6, 7, 9 New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15- 50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1)The submitted arborist reports dated September 1, October 6, and November 11, 2016 by Robert Booty; and 2)Appraised values prepared by Walter Levison for Rober Booty; and 3)The Project Data in Brief, the List of Trees, Appraised Values, the Conditions of Approval, and the map showing tree protection from this report. 2 74 19421 San Marcos Road Attachment 1 TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2) The necessit y to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the propert y. (3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularl y on steep slopes. (4) The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beaut y, property values, erosion control, and the general welfare of residents in the area. (5) The age and number of healthy trees the property is able to support according to good forestry practices. (6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7) Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8) Any other information relevant to the public health, safet y, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9) The necessit y to remove the tree for economic or other enjoyment of the propert y when there is no other feasible alternative to the removal. (10) The necessit y to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. 3 75 19421 San Marcos Road Attachment 3 TREE INFORMATION: Arborist Report reviewed: Preparer: Robert Booty, Consulting Arborist Dates of Reports: September 1, October 6 and November 11, 2016 Appraised Values: Walter Levison, November 11, 2016 Arborist reports were submitted to the City for this project that inventoried 38 trees protected by Saratoga City Code. Information on the condition of each tree, potential impacts from construction, suitability for preservation, appraised values and tree protection recommendations was provided. A table summarizing information about each tree is below. Nine trees (332, 335, 337, 338, 340, 341, 343, 349 and 356) protected by Saratoga Cit y Code are requested for removal to construct this project. They include four Mexican fan palms, two black walnuts, two crape m yrtles, and one Hollywood juniper. Table 2: Tree Information taken from the November 11, 2016 arborist report. 4 76 19421 San Marcos Road Attachment 3 Table 2: Tree Information continued. 5 77 19421 San Marcos Road Attachment 3 Table 3: Appraised Values from Walter Levison. 6 78 19421 San Marcos Road Attachment 3 7 79 19421 San Marcos Road Attachment 3 8 80 19421 San Marcos Road Attachment 4 CONDITIONS OF APPROVAL 1. It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2. All recommendations in the arborist report dated November 11, 2016 prepared by Robert Booty shall become conditions of approval. 3. The arborist report dated November 11, 2016 shall be copied on to a plan sheet, titled “Tree Preservation” and included in the final job copy set of plans. 4. The Project Data in Brief, the List of Trees and Appraised Values, the Conditions of Approval, and the map showing tree protection from this report dated January 20, 2017 shall be copied onto a plan sheet and included in the final set of plans. 5. The designated Project Arborist shall be Robert Booty, unless otherwise approved by the City Arborist. 6. Tree Protection Security Deposit a. Is required per City Ordinance 15-50.080. b. Shall be $49,770. c. Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d. May be in the form of cash, check, credit card payment or a bond. e. Shall remain in place for the duration of construction of the project. f. May be released once the project has been completed, inspected and approved by the City Arborist. 7. Tree Protection Fencing: a. Shall be installed as shown on the attached map. b. Shall be shown on the Site Plan. c. Shall be established prior to the arrival of construction equipment or materials on site. d. Shall be comprised of six-foot high chain link fencing mounted on eight-foot tall, 2-inch diameter galvanized posts, driven 24 inches into the ground and spaced no more than 10 feet apart. e. Shall be posted with signs saying “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, KATE BEAR (408) 868-1276”. f. Call City Arborist, Kate Bear at (408) 868-1276 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. g. Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 8. If contractor feels that work must be done inside the fenced area, call City Arborist to arrange a field meeting before performing work. 9 81 19421 San Marcos Road Attachment 4 9. The Project Arborist shall visit the site every two weeks during grading activities and every six weeks thereafter. Following visits to the site, the Project Arborist shall provide the City with a report including photos documenting the progress of the project and noting an y tree issues. 10. The Project Arborist shall be on site to monitor all work within: a. 15 feet of tree 329. b. 20 feet of tree 342. c. 25 feet of trees 325, 328, 344 and 361. 11. The Project Arborist shall supervise: a. Installation of house, walkway and patio by oak trees 325 and 329. b. Capping and/or removal of sewer line by tree 342. c. Installation of wall by tree 342. d. Installation of driveway by trees 361, 342 and 353. 12. No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 13. Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. 14. All construction activities shall be conducted outside tree protection fencing. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 15. Trenching to install utilities is not permitted inside tree protection fencing. 16. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. Roots measuring less than two inches in diameter may be cut using a sharp pruning tool. 17. Any permitted pruning or root pruning of trees on site shall be performed under the supervision of the Project Arborist and according to ISA standards. 18. Trees 332, 335, 337, 338, 340, 341, 343, 349 and 356 meet the criteria for removal and may be removed and replaced once Building Division permits have been obtained. 19. Trees permitted for removal shall be replaced on or off site according to good forestry practices, and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. The value of the removed trees shall be calculated in accordance with the ISA Guide for Plant Appraisal. 10 82 19421 San Marcos Road Attachment 4 20.New trees equal to $0 shall be planted as part of the project before final inspection and occupancy of the new home. New trees may be of any species. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 21.Replacement trees may be planted an ywhere on the propert y as long as they do not encroach on retained trees. 22.Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 23.Water loving plants and lawns are not permitted under oak tree canopies. 24.Should any tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessar y number of new trees, some of the value for trees may be paid into the City’s Tree Fund. 25.Following completion of the work around trees, and before a final inspection of the project, the applicant shall provide a letter to the City from the Project Arborist. That letter shall document the work performed around trees, include photos of the work in progress, and provide information on the condition of the trees. 26.At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call City Arborist for a final inspection. 11 83 $WWDFKPHQW >P v d W }}v&v ]vP ı ^v D }Z } 12 84 Attachment 3 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 09898999998 98103 103 103 102 102101 101100 100 10099 99 98 98979797 979696K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &NO! 1comments &&!$$!&’NORTHSOUTH COLLEGE CIRCLE ~~GASMETERNEW O/HELEC/TEL SVC.NEW O/HELEC/TEL SVC.NEW DOMESTIC WATER SVC.FROM EX. METERNEW DOMESTIC WATER SVC.FROM EX. METERWATER SVC.3030303030303030303029(E) TREES TO BE REMOVED OR RELOCATED. (REFER TO ARCHITECT)30TREE PROTECTION FENCING (TYP.)TREE LEGEND2'-8" HIGH LANDSCAPE WALL. CONCRETE BLOCK WITH STUCCO FINISHH A R D S C A P EL A Y O U TSCALE: 10" = 10'-0"05'10'20'30'MOTORIZED GATEGUYANCHORSCHAIN LINK FENCECHAIN LINK FENCEROLLED CURB & GUTTER L-1LAWNGARDEN PATIOINTERLOCKING PERMEABLE PAVERSMOTORCOURTINTERLOCKING PERMEABLE PAVERSGARBAGEGENERAL NOTESCONTRACTORS MUST BE PROPERLY AND CURRENTLY LICENSED BY THE CALIFORNIA CONTRACTORS STATE LICENSED BOARD PRIOR TO ENTERING INTO AN AGREEMENT TO PERFORM WORK AND MAY PERFORM ONLY SUCH WORK AS IS WITHIN THE SCOPE OF SAID LICENSED SPECIALTY.CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR COST INCURRED DUE TO DAMAGE AND REPLACEMENT OF SAID UTILITIES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION CONTRACTOR SHALL NOTIFY USA UNDERGROUND ALERT @ (800) 277-2600.NO MOW GRASSESNO MOW GRASSESBOULDERS AT TERMINUS OF WALLSUNKEN FIREPITGRAVEL PAVING AND WALKWAYTREE #325 PROTECTION NOTES: A.THE WALKWAY MUST BE INSTALLED ENTIRELY ON TOP OF GRADE AND OF PERVIOUS MATERIALS. B.THE STORM DRAIN NEEDS TO BE 15 FEET FROM THE TREE AND DUG BY HAND OR WITH AN AIR SPADE, LEAVING ALL ROOTS MEASURING TWO INCHES OR MORE INTACT. THE CONDUIT FOR THE DRAIN LINE CAN BE PLACED UNDER INTACT ROOTS. C.STEPPING STONES ARE TO BE PLACED ON TOP OF GRADE. D.ELECTRICAL WIRING FOR LIGHTING IS TO BE PLACED UNDER MULCH ON TOP OF GRADE OR UNDER INTACT ROOTS.WALKWAY INTERLOCKING PERMEABLE PAVERS4'-0" HIGH LANDSCAPE WALL. CONCRETE BLOCK WITH STUCCO FINISHSEAT BENCH / GARDEN WALLSINTERLOCKING PERMEABLE PAVERSART- TO BE SELECTEDPLANTING ISLAND AND BOULDERSPOURED IN PLACE CONCRETE STEPPING STONES WITH GRAVEL DEVIDERSDWNGRAVEL PAVING AND WALKWAYGARDEN CIRCLEP.A.P.A.P.A.P.A.P.A.P.A.MULCH ONLYP.A.METAL HEADER (TYP)P.A.P.A.P.A.P.A.P.A.P.A.3 STEPS DOWNP.A.STONE PAVINGPOTSBASIN-LESS FOUNTAIN URNP.A.P.A.P.A.BUILT IN BARBEQUE AND BARBAGE3114013163443473483493533523513503423553563583593613283273293263253233243763002014028" LOAK 9" LOAK 11" LOAK 24" PINE24" PINE 20" LOAK TWIN 12"30" OAK 12" LOAK 6"+8" PEPPER12" RDWD 8" LOAK 25" WALNUT8' RDWD24" OAK 36" WALNUT21" VOAK 18" LOAK 14" LOAK 18" RDWD 18" RDWD 14" LOAK 12" LOAK 14" OAK29" OAK 9" LOAK 17" OAK 24" LOAK 10' LOAK2929319338337335332330343292929292929345346REMOVEREMOVED R A I N A G E L E G E N D : S Y M B O L D E S C R I P T I O N 3" NDS ATRIUM GRATE 4" NDS ROUND GRATE 3" NDS BRASS DECK DRAIN 100 K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &NO! 1comments &&!$$!&’NORTHSCALE: 10" = 10'-0"05'10'20'30'18'-0"4'-0"13'-9"4'-9"9'-4"9'-4"5'-4"5'-4"4'-9"16'-9"33'-2"19'-0"20'-6"13'-6"2'-3"9'-0"2'-6"1'-2"15'-6"18'-0"19'-0"14'-6"3'-8"35'-8"16'-6"35'-8"16'-6"54'-4"3'-8"2'-6"11'-0"3'-2"54'-0"58'-8"31'-6"15'-2"14'-9"22'-3"42'-6"1'-0"34'-6"17'-6"4'-8"6'-6"30'-0"2'-6"10'-0"30'-8"2'-8"23'-6"19'-6"55'-3"7'-0"6'-9"14'-0"TYP.TYP.16'-0"DIMENSIONINGPLANL-2GENERAL NOTESCONTRACTORS MUST BE PROPERLY AND CURRENTLY LICENSED BY THE CALIFORNIA CONTRACTORS STATE LICENSED BOARD PRIOR TO ENTERING INTO AN AGREEMENT TO PERFORM WORK AND MAY PERFORM ONLY SUCH WORK AS IS WITHIN THE SCOPE OF SAID LICENSED SPECIALTY.CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR COST INCURRED DUE TO DAMAGE AND REPLACEMENT OF SAID UTILITIES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION CONTRACTOR SHALL NOTIFY USA UNDERGROUND ALERT @ (800) 277-2600.101 LAWNLAWNBUFFALO GRASSBUFFALO GRASSBUFFALO GRASSK A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &NO! 1comments &&!$$!&’NORTHSCALE: 10" = 10'-0"05'10'20'30'GENERAL NOTESCONTRACTORS MUST BE PROPERLY AND CURRENTLY LICENSED BY THE CALIFORNIA CONTRACTORS STATE LICENSED BOARD PRIOR TO ENTERING INTO AN AGREEMENT TO PERFORM WORK AND MAY PERFORM ONLY SUCH WORK AS IS WITHIN THE SCOPE OF SAID LICENSED SPECIALTY.CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR COST INCURRED DUE TO DAMAGE AND REPLACEMENT OF SAID UTILITIES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION CONTRACTOR SHALL NOTIFY USA UNDERGROUND ALERT @ (800) 277-2600.3 M I M - A U R 5 G A L5 A G A - D E S 5 G A L1 V I T - A N G 15 G A L35 C A R - T U M 1 G A L10 P E N - F A I 1 G A L2 A R B - M A R 15 G A L1 A C E - M A C 24" BOXP L A N T I N GP L A NL-336 P A N - V I R 1 G A L1 M E L - N E S 15 G A L12 M Y R - C A L 15 G A L3 L Y O - F L O 15 G A L3 A R B - M A R 15 G A L2 B R A - P O P 24" BOX2 A G A - V I L 5 G A L33 L O M - L I M 1 G A L3 D U D - B R I 5 G A L9 D I A - R E V 1 G A L1 Y U C - R O S 5 G A L1 C H O - T E R 5 G A L3 E R E - B L U 1 G A L9 C O N - M A U 1 G A L12 H E U - M A X 1 G A L4 X Y L - C O N 5 G A L46 L O M - L I M 1 G A L34 L O M - L I M 1 G A L3 A E S - C U R 1 G A L13 A N A - P I N 1 G A L2 T E C - O R A 5 G A L5 A R B - M A R 15 G A L6 D E S - C E S 1 G A L6 C H I - B U B 15 G A L9 C O T - O B L 5 G A L1 C H R - T E C 5 G A L9 B U L - H A R 1 G A L13 F E S - C A L 1 G A L6 A C A - C O U 5 G A L8" LOAK 9" LOAK 11" LOAK 24" PINE24" PINE 20" LOAK 12" LOAK 6"+8" PEPPER12" RDWD 8" LOAK 8' RDWD24" OAK 36" WALNUT21" VOAK 18" LOAK 14" LOAK 18" RDWD 18" RDWD 14" LOAK 12" LOAK 14" OAK29" OAK 9" LOAK 17" OAK 24" LOAK 10' LOAK3114013163443473483533523513503423403413553583593613283273293263253233243763002014023" THICK MULCH ONLY UNDER OAK TREES3" THICK MULCH ONLY UNDER OAK TREES3" THICK MULCH ONLY UNDER OAK TREES3" THICK MULCH ONLY UNDER OAK TREES3" THICK MULCH ONLY UNDER OAK TREES3" THICK MULCH ONLY UNDER OAK TREES3" THICK MULCH ONLY UNDER OAK TREES5 C I S - G R A 5 G A L22 S E S - A U T 1 G A L16 R H U - O V A 5 G A L5 E C H - F A S 5 G A L5 C O T - O B L 1 G A L4 S A L - E L E 1 G A L3 C E A - D A R 5 G A L5 A R C - D E N 5 G A L6 X Y L - C O N 5 G A L3 E N C - L O N 15 G A L2 L A G - S T D 24" B O X 16 P E N - K A R 1 G A L68 S E S - A U T 1 G A L10 R H A - C A L 5 G A L5 A C A - C O U 5 G A L3 L A U - N O B 24" B O X5 M I M - A U R 5 G A L36 D I A - R E V 1 G A L7 C H R - T E C 5 G A L6 C I T R U S sp. 15 G A L4 A G A - V I L 5 G A L1 C O T - M A C 1 G A L1 1 A G A - D E S 5 G A LTRANSPLANT (2) JAPANESE MAPLES FROM ON SITE 102 K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &PLANTING NOTESAND LEGENDSL-4P L A N T I N G N O T E S:GENERAL NOTATION: THE LANDSCAPE CONTRACTOR SHALL INSPECT THE SITE AND BE FAMILIAR WITH ALL EXISTING SITE CONDITIONS PRIOR TO BIDDING THE JOB. CONTRACTOR SHALL NOT WILLFULLY PROCEED WITH CONSTRUCTION AS SHOWN WHEN IT IS OBVIOUS THAT OBSTRUCTIONS, UTILITIES, LANDSCAPE GRADE DIFFERENCES, OR LANDSCAPE AREA DISCREPENCIES OCCUR ON SITE THAT HAVE NOT BEEN REPRESENTED ON THE DESIGN. SUCH CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE DESIGNER. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ALL NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCH NOTIFICATION. ALL LOCAL CODES AND ORDINANCES SHALL BE OBSERVED. PLANTING SHALL BE INSTALLED IN CONFORMANCE WITH ALL APPLICABLE LOCAL CODES AND ORDINANCES BY EXPERIENCED WORKMEN AND A LICENSED LANDSCAPE CONTRACTOR WHO SHALL OBTAIN ALL NECESSARY PERMITS AND PAY ALL REQUIRED FEES. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION BETWEEN TRADES AND SUBCONTRACTORS AS REQUIRED TO COMPLETE LANDSCAPE OPERATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES CAUSED BY OR DURING THE PERFORMANCE OF HIS/ HER WORK. ALL REPAIRS SHALL BE MADE AT NO COST TO THE OWNER. SOIL PREPARATION:THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR FINISH GRADING AND ALL PLANTING AREA DRAINAGE. POSITIVE DRAINAGE AWAY FROM HOUSE (2 % MIN.) SHALL BE MAINTAINED. NO LOW SPOTS WHICH HOLD STANDING WATER WILL BE ACCEPTED. THE LANDSCAPE CONTRACTOR SHALL INCORPORATE BACKFILL SOIL MIXES IN PLANTING AREAS AS NOTED BELOW. WHERE ROTOTILLING IS NOT POSSIBLE, WORK IN AMENDMENT WITH HAND TOOLS. AFTER INSTALLATION OF IRRIGATION SYSTEM, ALL PLANTING AREAS ARE TO BE FINE GRADED TO WITHIN 2 INCHES AND SLIGHTLY MOUNDED AWAY FROM EDGES OF TOP OF HEADER, CURB, WALK, PLANTER, ETC... AND RAKED SMOOTH WITH ALL ROCK AND DEBRIS OVER 1 INCH IN DIAMETER REMOVED.SOIL AMENDMENTS:THE LANDSCAPE CONTRACTOR SHALL INCORPORATE, BY MEANS OF ROTOTILLING, 6 CUBIC YARDS OF 'NITROFIED' SOIL CONDITIONER (WITH A PH OF 6.5 TO 7.5) AND 15 LBS. OF GRANULAR FERTILIZER (12-12-12) PER 1,000 SQUARE FEET OF PLANTING AREA INTO THE TOP 6" OF SOIL FOR ALL PLANTING AREAS EXCEPT AS NOTED BELOW: BACKFILL SOIL MIXES: PLANTING PIT MIX FOR TREES AND SHRUBS TO CONSIST OF 1/3 ORGANIC AMENDMENT AND 2/3 AMENDED TOPSOIL AS NOTED ABOVE.SHRUB PLANTING:THE SHRUBS SHALL BE SPOTTED AS PER PLAN. NO SUBSTITUTIONS UNLESS AUTHORIZED BY LANDSCAPE DESIGNER OR OWNER. ALL SHRUBS SHALL RECIEVE TURFGRO 20-10-5 PACKETS AT THE FOLLOWING RATIOS:(1) TABLET PER 1 GALLON, (2) TABLETS FOR 5 GALLON, AND (4) TABLETS FOR 15 GALLON.TREE PLANTING:THE TREES SHALL BE SPOTTED AS PER PLAN. TREES SHALL TYPICALLY BE LOCATED A MINIMUM OF FOUR (4') FEET FROM ALL CURBS, WALKS, HEADERS, BUILDINGS, OR OVERHANGS, AND OTHER TREES WITHIN THE PROJECT. TREE BACKFILL SHALL BE THE ‘PIT PLANTING MIX’ AS NOTED ABOVE. STD. TRUNK INDICATES A SINGLE TRUNK, AND A MULTI TRUNK INDICATES (3) TRUNKS FROM THE BASE OF TREE. DOUBLE STAKE ALL STANDARD TRUNK TREES. ALL TREES SHALL RECIEVE TURFGRO 20-10-5 PACKETS AT THE FOLLOWING RATIOS: (4) TABLET PER 15 GALLON, (5) TABLETS FOR 24" BOX, AND (6) TABLETS FOR 36" BOX AND LARGER. THOROUGHLY WATER ALL TREES IMMEDIATELY FOLLOWING PLANTING.TOP DRESSING:TOP DRESSING TO CONSIST OF 3" LAYER MEDIUM FIR BARK CHIPS FOR ALL PLANTING AREAS EXCEPT LAWN AND MEADOW GRASS. APPLY 'RONSTAR' PRE EMERGENT PRIOR TO TOP DRESS AT MANUFACTURER'S RECOMMENDED RATE. SODDED LAWN:SOD SHALL BE AS SPECIFIED ON DRAWINGS AND INSTALLED AS PER SUPPLIER'S SPECIFICATIONS. REMOVE FROM ALL TURF AREAS ALL STONES (1/2" AND LARGER), CONCRETE, MORTAR DEBRIS, ASPHALT, RUBBISH, DEBRIS, AND ANY MATERIALS HARMFULL TO PLANT LIFE. REMOVE AND/OR SPRAY TO ERADICATE NOXIOUS WEED GROWTH AND ROOTS. THOROUGHLY MIX AND PULVERIZE THE FOLLOWING MIX OF MATERIALS (LIGHTLY COMPACTED MEASUREMENTS) TO A MINIMUM DEPTH OF 6" WHILE IN A MOIST, FRIABLE CONDITION: 2" OF TOPSOIL 6 CUBIC YARDS NITROGEN STABILIZED SOIL AMENDMENT PER 1000 SQ. FT. 15 LBS. (16-16-8) FERTILIZER PER 1000 SQUARE FEETLAWN MAINTENANCE:PROTECT AND MAINTAIN EACH AREA BY WATERING, MOWING, RESODDING, ROLLING, OR RESEEDING AS NECESSARY FOR A MINIMUM OF 60 DAYS AFTER TURF INSTALLATION OR TO THE END OF THE 90 DAY MAINTENANCE PERIOD. ESTABLISH A THICK, WEED FREE, UNIFORM STAND OF TURF. APPLY WEED KILLER AT MANUFACTURER'S SPECIFIED RATE IF NECESSARY.MAINTANENCE:THE CONTRACTOR SHALL MAINTAIN THE PROJECT FOR 90 DAYS ( OR AS APPROVED BY OWNER ) UPON COMPLETION AND APPROVAL OF THE PROJECT. DURING THE ENTIRE MAINTENANCE PERIOD, WATERING, CULTIVATING, WEEDING, REPAIR OF STAKES AND TIES, AND SPRAYING FOR INSECTS AND DISEASES SHALL BE PERFORMED. AT THE END OF MAINTENANCE PERIOD, ALL AREAS SHALL BE FREE OF WEEDS AND ALL PLANT MATERIAL SHALL BE IN A HEALTHY, THRIVING CONDITION. SUBSTITUTIONS:REQUESTS FOR SUBSTITUTIONS OF PLANT MATERIAL TO BE MADE (5) DAYS PRIOR TO PLANTING.GUARANTEE: ALL CONSTRUCTION, TREES, SHRUBS, AND IRRIGATION BY LANDSCAPE CONTRACTOR AND/OR HIS SUBCONTRACTORS SHALL BE GUARANTEED FOR ONE (1) FULL YEAR AFTER THE BEGINNING OF THE MAINTENANCE PERIOD. THE CONTRACTOR SHALL REPLACE ANY AND ALL LANDSCAPE MATERIALS THAT ARE IN AN UNACCEPTABLE CONDITION FOR THE TIME OF USE, AND ANY PLANT MATERIAL THAT ARE NOT IN A VIGOROUS STATE OF GROWTH. THE CONTRACTOR SHALL NOT BE HELD LIABLE FOR LOSS OF PLANT MATERIAL DUE TO VANDALISM, ACCIDENTAL CAUSES, OR ACTS OF NEGLECT BY OTHERS THAN THE CONTRACTOR, HIS AGENTS, OR EMPLOYEES. PLANTING LEGEND :SYMBOLBOTANICAL NAMECOMMON NAME WUCOLS(water use rating)TREES:ACE MACAcer macrophyllumBig Leaf MaplemediumARB MARArbutus unedo ‘Marina’ (multi trunk)Strawberry TreelowBRA POPBrachychiton populneusKurrajonglowCHI BUBChilopsis linearis BubbaDesert WillowlowCOT GOLCotinus coggygria 'Golden Spirit'Smoke Tree VarietylowLAG STDLagerstroemia x fauerii 'Natchez' (standard trunk)Crape Myrtle (white)lowLAU NOBLaurus nobilis (multi trunk)Bay Tree lowLYO FLOLyonothamnus floribundusCatalina IronwoodlowMEL NESMelaleuca nesophilaPink MelaleucalowVIT MONVitex Montrose PurpleChaste TreelowSedum hispanicum 'Minus'by house at spaSUCCULENTS AND YUCCAS:AGA VILAgave vilmorinianaOctopus AgavelowAGA REGAgave victoriae reginaeAgave VarietylowAGA DESAgave desmentianano common namelowCIS GRACistanthe grandifloraRock PurslanelowCOT MACCotyledon macranthaPig's EarslowCOT OBLCotyledon orbiculata 'Oblonga'Pig's EarslowCOT ORBCotyledon orbiculata 'Lighthouse Road'Pig's EarslowDUD BRIDudleya brittoniiGiant Chalk DudleyalowENC LONEncephalartos longifoliaCycad VarietylowYUC ROSYucca rostrataBig Bend YuccalowEncephalartos altensteiniiinside courtFRUIT TREES:CIT TANCitrus 'Tango'Tango MandarinmediumFOR MARFortunella margarita 'Fukushu' (standard trunk)Tree Form KumquatmediumCIT BEACitrus aurantifolia 'Bears'Mexican LimemediumCIT VALCitrus sinensis 'Valencia'OrangemediumCIT MEYCitrus limon ‘Meyer’s Improved’LemonmediumCIT MORCitrus sinensis 'Moro'Blood OrangemediumCIT HYSCitrus hystrixKaffir LimemediumFIGFig ‘Brown Turkey’Fig TreemediumSHRUBS:ACA COUAcacia cognata 'Cousin It'Little River WattlelowARC DENArctostaphylos densiflora 'Howard McMinn'Manzanita VarietylowCEA DARCeanothus ‘Dark Star’Wild Lilacvery lowCHO TERChoisya ternataMexican OrangemediumECH FASEchium fastuosumPride Of MadieralowRHA OVARhapheolepis ovata ‘Minor’Dwarf Yeddo HawthornelowRHU OVARhus ovataSugar BushlowTEC ORATecoma Orange JubileeEsperanzalowXYL CONXylosma congestumShiny XylosmalowRosmarinus officinalis ‘Blue Spires’front entrylowGRASSES AND GRASSLIKE:ANA PINAnigozanthos 'Pink Beauty'Kangaroo PawmediumCAR TUMCarex tumulicolaBerkeley Sedge mediumCHR TECChrondropetalum tectorumGrass VarietymediumDIA REVDianella revoluta 'Little Rev'Little Rev Flax LilylowFES CALFestuca californicaFescue VarietymediumLOM LIMLomandra 'Lime Tuff'Mat RushlowPAN VIRPanicum virgatum 'Heavy Metal'Switch GrassmediumPEN FAIPennisetum 'Fairy Tails'Evergreen Fountain GrasslowPEN KARPennisetum orientale 'Karley Rose'Red Fountain GrasslowSES AUTSesleria autumnalisAutumn Moor GrassmediumPERENNIALS:AES CURAsclepias curassavicaBlood-flowermediumBUL HALBulbine frutescens 'Hallmark' Orange Stalked BulbinelowCON MAUConvolvulus mauritanicusGround Morning GlorylowERE BLUEremophila hygrophana Blue BellsBlue BellslowHEU MAXHeuchera maximaIsland Alum RootmediumMIM AURMimulus aurantiacus ‘Pumpkin’ Monkey FlowerlowPEN BOPPenstemon 'Margarita Bop'Beard TonguelowSAL CLESalvia clevelandii 'Winifred Gilman'Sage VarietylowSAL ELESalvia elegance ‘Pinapple Sage’Sage Varietylow* available at Devil Mountain Wholesale phone (925) 829 6006GROUND COVERS:Arctostaphylos 'Emerald Carpet' from Manzanita Varietylow1 gallon at 36" o.c. Triangular SpacingTeucrium chamaedrys 'prostratum'Germander Varietylowfrom 4" pots at 24" o.c. Triangular Spacing.Rosmarinus officinalis ‘Irene’ fromRosemarylowfrom 1 gallon at 24" o.c. Triangular Spacing.Scaveola 'Mauve Clusters' from flatsno common name low@ 12" o.c. Triangular SpacingLantana ‘Radiation’ from 4" pots atLantana Varietylow24" o.c. Triangular Spacing.Bouteloua dactyloides 'UC VERDE' UC Verde Buffalo Grasslowfrom plugs at 10" on centerPerennial bedding areaVaries mediumPROVIDE 4" DEEP PLANTING MIX No top dressing Bolero' dwarf fescue sodLawnhigh(dwarf fescue blend)BUFFALO GRASSLAWN12" DEEPER THANCONTAINER MINIMUM2 X DIAMETEROF ROOTBALLCINCH TIE OR APPROVED EQUAL10' LODGE POLE STAKESPLACED ON WINDWARDSIDE OF TREEROOT BALLA SHALLOW BASIN 2" DEEP SHALL BE FORMED AROUND ROOTBALL BELOW FINISH GRADE. TREES PLANTED IN LAWN SHALL NOT HAVE BASINAPPROVED BACKFILL THROUGHLY MIXED PRIOR TO INSTALLATIONNATIVE GRADE OR CERTIFIEDCOMPACTED BACKFILL.S T A N D A R D T R U N K T R E E P L A N T I N GTURFGRO 20-10-5 PACKETSPER SPECIFICATIONSWINDDIRECTIONPREVAILING3'' DIAMETER LODGPOLE PINE TREE STAKES (2) - LOCATE OUTSIDE OF ROOTBALL AND PERPENDICULAR TO PREVAILING WIND (SEE PLAN VIEW)ROOTBALLTRUNKTIESPITNOTES:1. APPROVED TREE TIES TO RUBBER STRAPS NAILED TO STAKES. NO WIRE CONNECTIONS ALLOWED.2. REMOVE ALL NURSERY STAKES FROM ROOTBALL. SIDES OF PLANT PIT TO BE VERTICAL. SCARIFY SIDES AND BOTTOM.3. DO NOT PLANT TREES WITHIN 10' OF SEWER OR DOMESTIC WATER LINES. DEPTH OF CONTAINER2 X D I A M E T E R O F R O O T B A L LA SHALLOW BASIN 2" DEEP SHALL BE FORMED AROUNDROOT BALL BELOW FINISH GRADE.ROOT BALL FINISH GRADE.APPROVED BACKFILL THROUGHLY MIXED PRIOR TO INSTALLATIONNATIVE GRADE OR CERTIFIED COMPACTED BACKFILLS H R U B P L A N T I N G D E T A I LTURFGRO 20-10-5 PACKETSPER SPECIFICATIONSS P E C I A L T Y P L A N T I N G D E T A I LBOULDERS (BUIRED 1/3RD DEEP)USE 3" THICK GRAVEL TOP DRESSING AROUND BOULDER PLANTINGSCACTUS OR AGAVENOTE: MAKE SURE THAT SPECIALTY PLANTS ARE AT A HIGH POINTSPECIALTY BLENDED BACKFILL(SEE PLANTING NOTES) PROPOSEDNATURAL FORM MULTI TRUNK TREE(NO STAKING)FINISH GRADELATERAL LINEPLANTING PITIS 3 TIMESDIAMETER OFROOTBALL2" WATERING BASINRAINBIRD RWS-BG ROOT WATERING SYSTEMBACKFILLN O S C A L E M U L T I T R U N K T R E E 103 09898999998 98103 103 103 102 102101 101100 100 10099 99 98 98979797 979696K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &NO! 1comments &&!$$!&’NORTHSCALE: 10" = 10'-0"05'10'20'30'GENERAL NOTESCONTRACTORS MUST BE PROPERLY AND CURRENTLY LICENSED BY THE CALIFORNIA CONTRACTORS STATE LICENSED BOARD PRIOR TO ENTERING INTO AN AGREEMENT TO PERFORM WORK AND MAY PERFORM ONLY SUCH WORK AS IS WITHIN THE SCOPE OF SAID LICENSED SPECIALTY.CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR COST INCURRED DUE TO DAMAGE AND REPLACEMENT OF SAID UTILITIES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION CONTRACTOR SHALL NOTIFY USA UNDERGROUND ALERT @ (800) 277-2600.I R R I G A T I O NP L A NL-5POINT OF CONNECTION TO WATER SUPPLY: VERIFY LOCATION IN FIELDINSTALL COMPRESSION TEE ON DOMESTIC WATER LINE AND CONNECT TO NEW 1 1/4" PVC MAINLINE. VERIFY A MINIMUM STATIC WATER PRESSURE OF 55 PSI. IF EXCEEDS 75 PSI, INSTALL PRESSURE REDUCING VALVE (SEE LEGEND) VERIFY A MINIMUM AVAILABLE FLOW OF 18 GPM.15'SERIES1" V / 23.14GPM12'SERIES3/4" V - 19.00GPMCO 1 1" 5.0 2 3/4" 1.7 3 3/4" 1.4 L-1 1" 5.6 4 1" 5.5 5 3/4" 1.4 8 3/4" 2.7 9 3/4" 3.4 L-2A 1" 5.2 L-2B 1" 4.8 6 3/4" 2.312'Q12'Q12'H12'Q12'H 12'H12'Q12'Q12'H 12'H12'Q12'H12'H12'Q12'H10'F10'F10'F10'F10'F 10'F 10'F8'F12'H12'Q12'H12'H12'H12'Q12'H 12'H12'H12'Q12'H12'-2708'H8'Q8'H8'Q12'H8'Q8'Q12'HL-3C 1" 2012'F12'F12'F12'F12'F12'F12'F12'F15'Q15'H15'F15'Q15'H15'Q15'F15'H15'H15'F15'H2.78L-3D 1" 20L-3E1" 24 10 3/4" 2.1 1 1 3/4" 1.7 15 3/4" 3.7 14 3/4" 2.0 13 3/4" 3.9L-3B 1" 19L-3A 1" 23 12 3/4" 4.4 7 3/4" 2.7 17 1" 7.2 16 3/4" 3.3WALL MOUNT CONTROLLER LOCATION:PROVIDE CONNECTION TO 120 VOLT POWER WITHIN RIGID STEEL CONDUIT FROM SOURCE WITHIN GARAGE. ALL ABOVE GRADE CONTROL WIRES SHALL BE CONTAINED WITHIN PVC ELECTRICAL CONDUIT SECURELY FASTENED TO WALL. FINAL CONTROLLER LOCATION TO BE COORDINATED WITH OWNER.NOTE; THIS PLAN IS DIAGRAMMATIC LOCATE ALL LATERAL LINES AND MAINLINES IN PLANTING AREAS AS POSSIBLE.AVOID TRENCHING UNDER DRIPLINES OF TREES~~GASMETERNEW O/HELEC/TEL SVC.NEW O/HELEC/TEL SVC.NEW DOMESTIC WATER SVC.FROM EX. METERNEW DOMESTIC WATER SVC.FROM EX. METERWATER SVC.104 105 K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &I R R I G A T I O ND E T A I L SL-7DRIP SYSTEM OPERATION INDICATOR(INSTALL INDICATORFLUSH WITH FINISHED GRADE)6" POP UP OPERATIONINDICATORXFS DRIPLINEN O S C A L E DRIPLINEP I P E T R E N C H I N GN O S C A L E 12" MIN.18" MIN.FINISH GRADECLEAN COMPACTED BACKFILLCONTROL WIRESUNDISTURBED SOIL PRESSURIZED MAINLINESEE SPECIFICATIONSLATERAL LINESSEE SPECIFICATIONSXFS SUB-SURFACE DRIPLINE AROUND TREEN O S C A L E 45321PVC DRIP MANIFOLD PIPEPVC SCH 40 TEE OR ELRAIN BIRD XF SERIES BLANK TUBINGBARB CROSS INSERT FITTING: RAIN BIRD XFD-CROSSBARB TEE INSERT FITTING: RAIN BIRD XFF-TEEPROJECTED CANOPY LINE OF TREESUB-SURFACE DRIPLINE: RAIN BIRD XF SERIES DRIPLINE POTABLE: XFS DRIPLINE NON-POTABLE: XFSP DRIPLINE PLACE AS SHOWN (LENGTH AS REQUIRED)ROOT BALL TIE DOWN STAKE: RAIN BIRD TDS-050 WITH BEND (QUANTITY AS REQUIRED, SEE NOTES 2-3 BELOW)61352347853596789NOTES:1. DISTANCE BETWEEN LATERAL RINGS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, AND TREE CANOPY. SEE RAIN BIRD XF-SDI DRIPLINE INSTALLATION GUIDE FOR SUGGESTED SPACINGS. 2. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN LOAM, AND FIVE FEET IN CLAY.3. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION. 4531/2" AIR RELIEF VALVE IN PVC HEADER21FINISH GRADESUBTERRANEAN EMITTER BOX: RAIN BIRD SEB 7XB1/2" AIR RELIEF VALVE: RAIN BIRD ARV050 TO BE INSTALLED AT HIGH POINTS IN DRIP ZONEPVC SCH 40 FEMALE ADAPTERPVC SCH 80 RISERBRICK (1 OF 2)PVC HEADER PIPEPVC SCH 40 TEE3" MINIMUM DEPTH OF 3#4" WASHED GRAVEL1263597864789N O S C A L E NOTE:1. ALLOW A MINIMUM OF 6-INCHES OF DRIPLINE TUBING IN VALVE BOX IN ORDER TO DIRECT FLUSHED WATER OUTSIDE VALVE BOX.2345167FLUSHING END CAPN O S C A L E FINISH GRADEFLUSH CAP FOR EASY FIT COMPRESSION FITTINGS: POTABLE:RAIN BIRD MDCFCAP NON-POTABLE: RAIN BIRD MDCFPCAPEASY FIT COUPLING: RAIN BIRD MDCFCOUPSUBTERRANEAN EMITTER BOX: RAIN BIRD SEB 7XBSUB-SURFACE DRIPLINE: RAIN BIRD XF SERIES DRIPLINE POTABLE: XFS DRIPLINE NON-POTABLE: XFSP DRIPLINE3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVELBRICK (1 OF 2) 3754216XFS SUB-SURFACE DRIPLINE N O S C A L E 4321EASY FIT COMPRESSION TEE: RAIN BIRD MDCFTEESUB-SURFACE DRIPLINE: RAIN BIRD XF SERIES DRIPLINE POTABLE: XFS DRIPLINE NON-POTABLE: XFSP DRIPLINEINLINE DRIP EMITTERTIE DOWN STAKE: RAIN BIRD TDS-050 WITH BEND (TYPICAL)TURF/FINISH GRADE OR SHRUB BED WITH MULCH124"-6"NOTES:1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, F0UR FEET IN LOAM, AND FIVE FEET IN CLAY.2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION SUCH AS TEES OR ELBOWS, USE TIE-DOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION. 3. INSERTION PLOW AND TRENCHED INSTALLATIONS DO NOT REQUIRE TIE DOWN STAKES.3455B A C K F L O W P R E V E N TI O N D E V I C E N O S C A L E 12" min, 24" max18"CONCRETE SUPPORT BLOCK 8" X 8" LENGTH BETWEEN ELBOWS MINIMUMSCH. 40 PVC MAIN LINE TO VALVESPVC MALE ADAPTER(TYP. BOTH SIDES)SCH. 40 PVC MAIN LINETO POINT OF CONNECTIONG.I. FITTING AS REQUIREDEVENLY COAT ALL GALVINIZEDFITTINGS EXPOSED TO SOIL AND CONCRETE WITH 3M PVC TAPE OR EQUAL.(1" OVERLAP)BRASS UNION (2) TOTALFINISH GRADEREDUCED PRESSURE BACKFLOWASSEMBLE AS SPECIFIED.INSTALL PER MANUFACTURER'SINSTRUCTIONSLOW-VOLUME CONTROL SYSTEM (RAINBIRD XCZ-SERIES ; 075 AND 100)N O S C A L E FLOW3/4" PRV45 PSI LFREMOTE CONTROLVALVE PVC MAINLINE2" MINIMUMCLEARANCEPVC OR POLYLATERAL LINEVALVE BOX12" X 18"1 CU. FT. PEAGRAVEL SUMPBRICK SUPPORT(1- EA. CORNER)200 MESS FILTER3/4" SCH 40RED BUSHING TXTN O S C A L E XFS SUB-SURFACE DRIPLINE LAYOUT45321PVC SUPPLY HEADERPVC SCH 40 TEE OR EL (TYPICAL)BARB X MALE FITTING: RAIN BIRD XFF-MA FITTING (TYPICAL)PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL ZONE VALVE KIT (SIZED TO MEET LATERAL FLOW DEMAND)SUB-SURFACE DRIPLINE: RAIN BIRD XF SERIES DRIPLINE (TYPICAL) POTABLE: XFS DRIPLINE NON-POTABLE: XFSP DRIPLINEPERIMETER OF AREAPERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4" FROM PERIMETER OF AREAFLUSH POINT (TYPICAL) - SEE RAIN BIRD XFS DETAILS FOR FLUSH POINT INSTALLATIONBARB X BARB INSERT TEE OR EL: RAIN BIRD XFF-TEE OR RAIN BIRD XFF-ELBOW (TYPICAL)PVC RISER PIPEPVC SUPPLY MANIFOLDPVC SCH 40 SLEEVE PIPE SIZED TWICE THE SIZE OF MANIFOLD PIPE SIZEPAVEMENT AND CURBTURF OR MULCHFINISH GRADE1#2" AIR RELIEF VALVE: RAIN BIRD MODEL: ARV050 SEE RAIN BIRD XFS DETAILS FOR AIR RELIEF INSTALLATION678910NOTES:1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND CHANGES IN ELEVATION. SEE INSTALLATION SPECIFICATIONS ON RAIN BIRD WEB SITE (WWW.RAINBIRD.COM) FOR SUGGESTED SPACING. 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED THE MAXIMUM SPACING SHOWN IN THE ACCOMPANYING TABLE. 3. INSTALL AIR RELIEF VALVE AT HIGH POINTS IN DRIP LATERAL.4. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50PSI, IT IS RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. 11121314151621397INSET B458INSET AINSET B6FP2"-4"FPFP4-6"DRIP MANIFOLD BURIAL DEPTH4421210INSET A42101213AR16151415DRIP CONNECTION: PVC TO POLYTUBE ON GRADECXCXFPT SCH. 40 PVC FITTING CONNECTION.580 POLYTUBE DRIPLINE3/4" MALE ADAPTERP.V.C. TEEP.V.C. PIPING (LATERAL LINE)USE FIR BARK MULCH COVER- SEE PLANTING SPECIFICATIONS FOR TYPE AND DEPTH12" MIN.F I L T E R / P R E S S U R E R E G U L A T O R PRESSURE REDUCING VALVE (PRE SET TO 40 PSI)TO VALVEUSE A STANDARD BRICK OR FLAT STONE UNDER EACH CORNER OF VALVE BOX TO LEVELFILTER WITH SCREEN(ROTATE FILTER TO BELOW HORIZONTAL POSITION)FINISH GRADESCH. 40 PVCMAIN LINECARSON 1419 PLASTIC VALVE BOX OR EQUAL APPLY 3" GRAVEL PEA GRAVELAT BASE OF BOX TO PREVENT SILTATIONN O S C A L E 106 K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &NO! 1comments &&!$$!&’NORTHSCALE: 10" = 10'-0"05'10'20'30'GENERAL NOTESCONTRACTORS MUST BE PROPERLY AND CURRENTLY LICENSED BY THE CALIFORNIA CONTRACTORS STATE LICENSED BOARD PRIOR TO ENTERING INTO AN AGREEMENT TO PERFORM WORK AND MAY PERFORM ONLY SUCH WORK AS IS WITHIN THE SCOPE OF SAID LICENSED SPECIALTY.CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR COST INCURRED DUE TO DAMAGE AND REPLACEMENT OF SAID UTILITIES PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION CONTRACTOR SHALL NOTIFY USA UNDERGROUND ALERT @ (800) 277-2600.L I G H T I N GP L A NL-8ttL I G H T I N G L E G E N D :S Y M B O L D E S C R I P T I O N UNIQUE LIGHTING GEMINI SURFACE MOUNT NICHELIGHTGEMI-12-L2 (WEATHERED BRASS) UNIQUE LIGHTING VOYAGER SURFACE MOUNT STEPLIGHTVO8L-12-L2 (WEATHERED BRASS) UNIQUE LIGHTING SOLARIS PATHLIGHT SOLA-12-L2 (WEATHERED BRASS)UNIQUE LIGHTING VENUS PATHLIGHT VENU-12-L2 (WEATHERED BRASS) UNIQUE LIGHTING STELLAR WALL LIGHTSTEL-12-L2 (WEATHERED BRASS)UNIQUE LIGHTING LEDGE LIGHT ISO IS6-27K-BZ-L2 (WEATHERED BRASS)UNIQUE LIGHTING HANGING DOWNLIGHTOBSE-12-L2 (WEATHERED BRASS)UNIQUE LIGHTING NORTHSTAR DOWN LIGHT (TREE MOUNT) NSOS-12-L427 (WEATHERED BRASS)UNIQUE LIGHTING ORBITAL HANGING DOWN LIGHT ORBI-NL-BZ (BRONZE) (WITH LED-2W-M1FL27K-12 LAMP)UNIQUE LIGHTING TRANSFORMER500SS-SL - ( SWITCHING BY OTHERS)t107 K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &NO! 1comments &&!$$!&’3114013163443473483493533523513503423553563583593613283273293263253233243763002014028" LOAK 9" LOAK 11" LOAK 24" PINE24" PINE 20" LOAK TWIN 12"30" OAK 12" LOAK 6"+8" PEPPER12" RDWD 8" LOAK 25" WALNUT8' RDWD24" OAK 36" WALNUT21" VOAK 18" LOAK 14" LOAK 18" RDWD 18" RDWD 14" LOAK 12" LOAK 14" OAK29" OAK 9" LOAK 17" OAK 24" LOAK 10' LOAKSOUTH COLLEGE CIRCLE 6"+8" TREE TAG 31918" PALM TAG 343REMOVE TREE6" MAPLETAG 3306"+8" CYP. TAG 33214" PALM TAG 33714" PALM TAG 33814" PALM TAG 335343332338335REMOVE TREEREMOVE TREES6" FRUIT TAG 336REMOVE TREERELOCATE TREESEE PLANTING PLAN337TREE REMOVALPLANL-9REMOVE TREESRELOCATE TREESEE PLANTING PLAN6' HIGH CHAIN LINK TREE PROTECTION FENCING FENCING TO REMAIN IN PLACE FOR DURATION OF PROJECT6' HIGH CHAIN LINK TREE PROTECTION FENCING FENCING TO REMAIN IN PLACE FOR DURATION OF PROJECT6' HIGH CHAIN LINK TREE PROTECTION FENCING FENCING TO REMAIN IN PLACE FOR DURATION OF PROJECTTREE PROTECTION NOTES1. TREE BRANCHES THAT WILL INTERFERE WITH CONSTRUCTION EQUIPMENT SHALL BE PROPERLY PRUNED PRIOR TO BEGINNING CONSTRUCTION. PRUNING SHALL BE AS APPROVED BY THE CITY AND SHALL COMPLY WITH CITY APPROVED PRACTICES.2. A PROTECTIVE FENCE SHALL BE PLACED AT THE DRIPLINE OF THE EXISTING TREES DURING THE ENTIRE CONSTRUCTION PERIOD. NO WORK SHALL OCCUR WITHIN THE DRIPLINE EXCEPT UNDER THE DIRECT SUPERVISION OF A CERTIFIED ARBORIST APPROVED BY THE CITY.3. SOIL COMPACTION AND GRADING SHALL BE AVOIDED UNDER THE DRIPLINE OF THE TREES. MAINTAIN A POSITIVE DRAINAGE AWAY FROM TREE TRUNK. IRRIGATION SHOULD BE AVOIDED UNDER NATIVE OAK TREES.4. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL OCCUR WITHIN 25 FEET OF THE DRIPLINE OF THE TREES.5. ALL ROOTS 1" OR LARGER THAT MUST BE SEVERED SHALL BE CUT MANUALLY TO PRODUCE A CLEAN CUT AND TREATED WITH A TREE SEALANT. BORING, RATHER THAN TRENCHING, SHALL BE REQUIRED WHERE IT IS UNAVOIDABLE FOR PIPING TO CROSS THROUGH THE DRIPLINE OF A TREE. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING COMPARABLE REPLACEMENT TREES FOR ANY EXISTING TREES THAT ARE FOUND BY THE CITY TO BE IRREPARABLY DAMAGED DUE TO CONSTRUCTION ACTIVITY.REMOVE REMOVE 345346108 K A T A R Ur e s i d e n c e19421SAN MARCOS ROADSARATOGA, CA.REV! NO!commentsJob No:Date: "#$%#&’Drawn:Scale: &( ) &*+,*(mfhNOTE:This plan is diagrammatic in nature! It is meant as a general guide to construction only! It is not fully detailed nor exhaustively speci-ed!It is the responsibility of the contractor to become familiar with the site prior to starting work! Notify landscape designer promptly with any -eld discrepancies! It is the responsibility of the contractor and# or owner to verify. select. and resolve all structures. water features. and planting materials! The contractor and owner are soley responsible for quality control. construction standards and for maintaining compliance with local andcounty codes on this project!LICENSEDARC H IT E C T LA /"&"REN! *0,1*,&’MARTINHOFFMANNS OFCIOALRNIAFT A TELANDSCAPEhM a r t i n H o f f m a n n LANDSCAPE ARCHITECT4713 First StreetSuite 205Pleasanton, Ca94566925 462 2190NO! $comments &*!&&!&’NO! &D.G. P A V I N GNOT TO SCALESTABILIZED DECOMPOSED GRANITE(INSTALL IN 1" LIFTS)CLASS II AGGREGATE BASE(COMPACT TO 90 %)METAL HEADER TO BE SELECTEDMETAL STAKESHOLD FINISH GRADE OF ADJACENT PLANTING AREA TO 1 1/2" BELOW TOP OF HEADER (TYP)3"2"COMPACTED SUBGRADE(COMPACT TO 88 %)GD E T A I L SL-10LIMESTONE BACKSPLASHS C R E E N F E N C E E L E V A T I O N SCALE: 1/2" = 1'-0"EHORIZONTAL WOOD FENCE (STAINED WESTERN RED CEDAR)GATE6'-0"3'-6"6'-9"3'-6"11'-0"3'-8"1'-1"2'-2"2'-8"SINK TO BE SELECTEDREFRIGERATORBUILT IN BARBEQUEGRANITE COUNTERTOPB A R B E Q U E L A Y O U TSCALE: 1/4" = 1'-0"LIMESTONE VENEER ON BACKSPLASH AND OUTER WALLSSTUCCO VENEER INERIOR WALLSB B E N C H S E A T A N D F I R E P I T S E C T I O NSCALE: 1/4" = 1'-0"CONCRETE BLOCK BENCH SEAT WITH STUCCO VENEER1'-6"3"10"1'-2"TAPERED SURFACE2'-2"3"1'-2"2'-0"2'-4"FINISH GRADEA 2'-0"F I R E P I T E L E V A T I O NSCALE: 1/4" = 1'-0"CONCRETE BLOCK STEM WALL WITH STUCCO VENEER3'-0"1'-9"1'-6"2'-4"1'-2"6'-0"STUCCO VENEERLIMESTONE VENEERCUSHIONS7"3'-0"1'-4"FINISH GRADEA 3'-6"LIMESTONE VENEERSTUCCO VENEERMETAL DOORSGRANITE COUNTERTOPB A R B E Q U E E L E V A T I O N SCALE: 1/4" = 1'-0"B 3'-6"1'-1"2'-10"3'-4"B A R B E Q U E I N T E R I O R SCALE: 1/4" = 1'-0"B 109 REPORT TO THE PLANNING COMMISSION Meeting Date: February 8, 2017 Application: PDR16-0028 & VAR16-0001 Location / APN: 14253 Worden Way / 397-26-062 Owner/Applicant: Rajat Monga & Sonu Durgia / Rockwood Design Associates Staff Planner: Christopher Riordan 14253 Worden Way SITE 110 Page 2 of 6 Summary PROJECT DESCRIPTION: The applicant requests Design Review and Variance approval for a 262 square foot second-story addition to an existing 4,497 square foot two-story single-family residence. The total proposed square footage is 4,759 square feet. A Variance is requested to exceed the 4,128 square feet maximum floor area allowed by the net lot area. The site has a net lot size area of 23,671 square feet and is zoned R-1-12,500. STAFF RECOMMENDATION: Adopt Resolution No. 17-004 denying the project. Variance Approval by the Planning Commission is required pursuant to Code Section 15-70.050. Design Review Approval by the Planning Commission is required pursuant to Code Section 15- 45.065(a)(3). PROJECT DATA: Site Area: 42,878 sq. ft. gross - 18,839 sq. ft. Santa Clara Water District easement - 368 sq. ft. Street Right of Way easement 23,671 sq. ft. net lot area Average Site Slope: 21% General Plan Designation: M-12.5 Zoning: R-1-12,500 Proposed Allowed/Required Conformance Proposed Site Coverage Residential Footprint Concrete Driveway / Patio Deck Swimming Pool Total Proposed Site Coverage 2,882 sq. ft. 3,117 sq. ft. 305 sq. ft. 1,000 sq. ft. 7,304 sq. ft. (30.9%) 13,010 sq. ft. Conforms Floor Area First Floor Second Floor (Existing) Second Floor (Addition) Total Floor Area 3,428 sq. ft. 1,069 sq. ft. 262 sq. ft. 4,759 sq. ft. 4,128 sq. ft. Variance Requested Height (Residence) Lowest Elevation Point: Highest Elevation Point: Average Elevation Point: Proposed Topmost Point: Total Proposed Height 448.13 450.89 449.51 475.42 (25.11 Ft.) 26 Feet Conforms 111 Page 3 of 6 Setbacks Front Left (First Floor) Left (Second Floor) Right (First Floor) Right (Second Floor) Rear (First Floor) Rear (Second Floor) 22’-6” 49’-1” 49’-1” 12’-6” 47’-2” >50 >50 25’ 10’ 15’ 10’ 15’ 25’ 35’ No change to existing setbacks PROJECT DESCRIPTION Background: On October 25, 2016, the Planning Commission visited the project site and held a Study Session to provide a preliminary review of the project. The Commission discussed the application with staff and the applicant at the Study Session and provided comments. Site Description: The project site is located at 14253 Worden Way. Existing on the site is a 4,497 square foot two-story ranch style single-family residence, swimming pool, and related site improvements. The sites gross square footage is 42,878 square feet. However, the site is constrained by two easements including an 18,839 square foot easement to the Santa Clara Valley Water District (SCVWD) and a smaller 368 right-of-way easement for Worden Way. The calculated net site area after subtracting the area of the two easements is 23,671 square feet. Total allowable floor area for structures is required by the Zoning Ordinance to be based on a sites net lot size. Subtracting the area of the easements from the gross lot size results in a maximum allowable floor area of 4,128 square feet. The existing residence exceeds the allowable floor area by 369 square feet. Other easements on the site which limits its development potential include an open space easement and a storm drain easement. These easements do restrict the location of structures but are not subtracted from gross lot size. Saratoga Creek borders the site to the west. Single-family residences are located on adjacent sites from the north to the south. Project Description: The floor area of the residence includes a 2,882 square foot first story and a 1,069 sq. ft. second story. The second floor does not extend the entire width of the structure creating 546 square feet of interior area spaces which exceed 15 feet in height. The Zoning Ordinance requires that any area with an interior height of 15 feet or greater be double counted towards the sites maximum allowable floor area. The proposed project would horizontally enlarge the size of the second floor by 455 feet into the larger volume open area that is required to be double counted as floor area. This expansion would add additional interior second story space but would not count as new floor area because it would be filling in the area that was already double counted. The footprint of the building would not be enlarged. Due to the pitch of the existing roof, enlarging the second floor would result in second floor areas with ceiling heights of less than five feet. The Zoning Ordinance states that interior areas 112 Page 4 of 6 with ceiling heights of less than five feet are not included in a projects overall floor area. The project would raise the height of the existing roof over the area of the expanded second floor. Raising the height of the roof would create new areas that exceed five feet thereby increasing the floor area of the structure by an additional 262 sq. ft. for a total project square footage of 4,759 sq. ft. Variance: As mentioned in preceding paragraphs, the gross lot size is 42,878 square feet and the net lot size is 23,671 square feet after deducting the area of the water district and right-of-way easements. When calculating a sites allowable floor area, the net site area (23,671 square feet) is further reduced by a slope adjustment factor of 33% based on the average slope of the site. This reduced net site area of 15,860 square feet is the number used to calculate the sites allowable floor area of 4,128 square feet. The existing house has a floor area of 4,497 square feet which currently exceeds the sites allowable floor by 369 feet. The project would increase the floor area by an additional 262 square feet resulting in a residence that exceeds the sites allowable floor area by a total of 631 feet and increasing the nonconformity of the structure To grant a variance the Planning Commission must be able to make all of the following findings provided in City Code Section 15-70.060 based on the application and the evidence submitted. Staff has evaluated the project and the applicants request for a variance for additional floor area to exceed that allowed on the site. Staff is not able to make the findings for the variance and is not recommending approval. Variance Findings (a) That because of special circumstances applicable to the property, including size, shape, topography, location or surroundings, strict enforcement of the specified regulation would deprive the applicant of privileges enjoyed by the owners of other properties in the vicinity and classified in the same zoning district. This finding cannot be made in the affirmative in that the areas of the water district easement and the right-of-way easements were depicted on the original parcel map which created the subject parcel. When the house was constructed it would have been subject to the sites floor area regulations based on the existing easements. Other properties in the vicinity as well as properties within the same zoning district which are burdened by water district easements are subject to the same restrictions which reduce gross lot size and subsequent reductions in floor area The existing house is nonconforming because it exceeds the sites allowable floor area and by granting a variance for additional floor area would increas e the degree of noncompliance. (b) That the granting of the variance will not constitute a grant of special privilege inconsistent with the limitations on other properties in the vicinity and classified in t he same zoning district. This finding cannot be made in the affirmative in that granting of the variance to increase the square footage of the residence and further exceed the sites allowable floor 113 Page 5 of 6 area could result in the granting of a special privilege t hat would be inconsistent with other properties in the vicinity and in the same zoning district. All single -family residentially zoned properties within the City are subject to floor area limitations based on lot size. It is also common for a sites allow able floor to be restricted by easement reductions (creek or right -of-way) and many lots bordering Saratoga Creek are subject to net site reductions and floor area limitations because of the existence of easements. (c) That the granting of the variance w ill not be detrimental to the public health, safety or welfare, or materially injurious to properties or improvements in the vicinity. This finding can be made in the affirmative in that the proposed project would be subject to building department review to ensure compliance with the 2016 California Building Code prior to issuance of a building permit. Materials and Colors: Detail Colors and Materials Exterior Off white colored smooth stucco Trim Off white Roof Grey colored standing seam metal roof Design Review : The residence has an existing ranch style appearance which would be modified to an updated contemporary architectural style. The horizontal wood siding would be removed and replaced with stucco. All windows would be replaced with new windows. The asphalt roof would be replaced with a standing seam metal roof. All the stone detailing would be removed and replaced with stucco. The project as proposed would add 262 square feet of floor area to the existing second story. Design Review approval is required for any addition to an existing structure that would expand the second story floor area by more than 100 square feet. With the exception of the additional square footage, all the exterior changes to the structure, including the increase in roof height, could be approved by the issuance of a building permit without public review. While staff could support the findings for Design Review as the project is minimally increasing the existing mass of the structure and there is little privacy impact to neighboring properties, the City Code requires that all structures requiring design review approval to comply with the floor area standards unless the Planning Commission grants a variance. Staff cannot make the findings for approval of the variance for additional floor area so therefore the Design Review application cannot be approved. Neighbor Notification and Correspondence: The applicant submitted one (1) Neighbor Notification Form signed by an adjacent property owner with no negative comments. A copy of the neighbor notification forms is included as Attachment #3. A Public Notice was sent by the Community Development Department to property owners within 500 feet of the site. No additional concerns have been brought to the City’s attention as of the writing of this staff report. 114 Page 6 of 6 STAFF RECOMMENDATION: Adopt Resolution No. 17-004 denying the project. ATTACHMENTS: 1. Resolution of Denial of Variance 2. Neighbor Notification form 3. Written Project Description (submitted by applicant) 4. Easement Exhibit (submitted by applicant) 5. Development Plans (Exhibit "A") 115 RESOLUTION NO. 17-004 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION DENYING AN APPLICATION FOR A FLOOR AREA VARIANCE AND DESIGN REVIEW APPLICATION FOR PROPERTY LOCATED AT 14253 WORDEN WAY. WHEREAS, an application was submitted to the City of Saratoga by Rockwood Design Associates on behalf of Rajat Monga & Sonu Durgia for Design Review and Variance approval for a 262 square foot addition to an existing 4,497 square foot single-family residence. The total proposed square footage would be 4,759 square feet. A Variance is requested for the project to exceed the sites allowable floor area of 4,128 square feet. The site has a net lot size area of 23,671 square feet and is zoned R-1-12,500. The foregoing are collectively described as the “Project” in this Resolution; and WHEREAS, On October 25, 2016 the Planning Commission visited the project site and held a Study Session to review the project. The Commission discussed the application with staff and the applicant and provided project related comments; and WHEREAS, on February 8, 2017, the Planning Commission held a duly noticed public hearing, provided all interested parties a full opportunity to be heard and to present evidence and argument, and considered all evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: After careful consideration of the architectural drawings and other exhibits and evidence submitted in connection with this matter, the findings for denial of a Variance application set forth below are hereby made, Application No. VAR16-0001 for Variance approval was voted on and is hereby denied by the Planning Commission. Section 3: The Planning Commission finds that the Project is inconsistent with the Variance findings that there does not exist special circumstances applicable to the project with respect to net lot size and that the granting of a Variance for additional floor in excess of what is allowed on the site could grant a special privilege inconsistent with the limitation on other properties in the vicinity. Section 4: Per City Code Section 15-45.020, all structures requiring design review are to comply with the floor area standards unless the Planning Commission grants a variance from the floor area regulations pursuant to City Code Article 15-70. The Planning Commission did not make the findings to approve the variance for additional floor area and Application No. PDR16-0028 the design review application is hereby denied. Section 5: Unless appealed pursuant to the requirements of Article 15-90 of the Saratoga City Code, this Resolution shall become effective fifteen (15) days from the date of its adoption on February 23, 2017. Attachment 1 116 Resolution No. 17-004 PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 8th day of February 2017 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Tina Walia Vice Chair, Planning Commission 117 Attachment 2 118 119 120 121 122 123 124 125 126 Address 14253 Worden Way Saratoga, CA 95070 You can enter notes here 25'- 0 "28'-91/2"13'-91/2"15'-0"23'-61/2"25' - 2 1/4 " 71' - 0 "17'-01/2"12' - 6 "20'-91/2"47' - 2 1/4 "17'-0"22'-81/2"NEW GATE & NEW FENCE AT PROPERTY LINE 4104104104104104124124124124124124144144144144144144164164164164164164184184184184184184204204204204204204204224224224224224224244244244244244244244264264264264264284284284284304304304304324324324324344344344344364364364364384384384384404404404404424424424424444444444464464464464484484484484484504504 5 0450 450450452452452TOP CREEKTOP CREEK TO P C R E E K TOE CREEKTOE CREEKTOP CREEKTOE CREEKTOE CREEKTOE CREEKTOP CREEKTOP CREEKTOP CREEKTOP CREEKGB TOEGB TOEGB TOEG B GB 6' CHAIN LINK FENCE6' CHAIN LINK FENCE/ GB TOP20"OAK42"TREE18"TREE14"OAK3'GATE48"OAK50"OAKDBL 38"TREE20"OAK3'GATE18"OAKAC UNIT FF20"TREE14"TREE16"TREE /DEADFFED G E O F A CEDGE OF ACGFSPG&E3/4" I .P . -OPEND/WEDGEOF AC36"OAKCREEKCREEKW O R D E N W A Y PARCEL MAP(411 M 32)PARCEL A0.984± AC. GROSS0.976± AC. NETPARCEL BPARCEL D S.C.V.W.D.EASEMENTBK. D373, PG. 615OPEN SPACEEASEMENT411 M 32CL 10' STORM DRAINEASEMENT411 M 32CL PUBLIC UTILITY, ACCESSS.S.E. EASEMENT411 M 32GATE PLANTERPLANTER (E) POOL TO BE REMODEL(N) FIRE PITPLANTERPLANTER(N) CONCRETE/ COPING (N) DECK (N) ENTRY (E) PATH (E) PATH DRIVEWAY 26.1'15.1'49. 1 '5.0'5.0'L=44.69'D=80°00'58"R=32'448.49452.43452.43451.60FF448.30448.13450.59450.89450.79426.33'N35°10'00"W191.17'N38°18'10"W44.98'N14°09'53"E115 . 7 4 ' N5 2 ° 5 8 ' 3 7 " E 171.44'N37°41'27"W193.94'N24°34'44"E25'-0" FR O N T S E T B A C K 10'-0" SIDE SETBACK FIRST F L O O R 15'-0" SIDE SETBACK SECON D F L O O R 10'-0" SIDE SETBACKFIRST FLOOR15'-0" SIDE SETBACKSECOND FLOOR10'-0" SIDE SETBACK FIRST FLOOR15'-0" SIDE SETBACK SECOND FLOORROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZG1.1SCALE 1" = 20'-0"M O N G A _ D U R G I A R E S I D E N C E1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .DESIGN FIRM: ROCKWOOD DESIGN ASSOCIATES, INC. 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 PROJECT MANAGER: ADAM ROCKWOOD AIA ASSOC. PROJECT DESIGNER: LORENA PEREZ AIA ASSOC. 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET LOCATION MAP ASSESSOR MAP 1 PROPOSED SITE PLAN Owner Rajat Monga and Sonu Durgia 14253 Worden Way Saratoga, CA. 95070 APN 397-26-062 Zoning R-1-12,500 15-12.050 Site Area Interior lot shall be 12,500 s.f. 15-12.070 Frontage, Width and Depth Frontage: 65’-0” Site Width: 90’-0” Site Depth: 120’-0” 15-12.080 Site Coverage 55% Note: Solid surface decks and compacted surfaces made of porous materials used for walkways, driveways and patios will be counted at only fifty percent of the total area of such surfaces for determining the calculation of site coverage within this Section. 15-12.090 Front, Side and Rear Setbacks Front: 25’-0” First Floor Side: 10’-0” Second Floor Side: 15’-0” Rear First Floor: 10’-0” Rear Second Floor: 10’-0” REFER TO SITE PLAN THIS SHEET FOR EXISTING SETBACKS- NO CHANGES PROPOSED. 15-80.010 Exceptions to Setback Areas (B)- Aboveground balconies, porches, decks, platforms, stairways and landing places, which are open, unenclosed, uncovered and no part of which is more than four feet above finish grade, may extend into a required setback area or space between buildings not more than four feet. 15-12.100 Height of Structures 26’-0” max. INDEX: G1.1 TITLE PAGE & SITE PLAN SUR 1 SURVEY SUR 1 SURVEY A1.0 EXISTING FLOOR PLAN A1.1 FIRST FLOOR A1.2 SECOND FLOOR & ROOF PLAN A2.1 ELEVATION EXISTING & PROPOSED A2.2 ELEVATION EXISTING & PROPOSED A2.3 SECTION EXISTING & PROPOSED A2.4 SECTION EXISTING & PROPOSED M O N G A _ D U R G I A R E S I D E N C E FLOOR AREA CALCULATION SEE SHEET 3/A2.4 FOR SQ.FT. DIAGRAM: (E) FIRST FLOOR SQ.FT. + A_976 + B_312 + C_437 + D_524 + E_633 (GARAGE) +2,882 SQ.FT. (E) FIRST FLOOR CEILING +15' SQ.FT. + F_222 + G_147 + H_177 +546 SQ.FT. (E) SECOND FLOOR SQ.FT. + J_1,069 +1,069 SQ.FT. TOTAL (E) RESIDENCE = 4,497 SQ.FT. (N) SECOND FLOOR ADDITION SQ.FT. + K_717 + 717 SQ.FT. PROPOSED DEMO (+15') CEILING SQ.FT. AT FIRST FLOOR + L_369 + M_86 - 455 SQ.FT. PROPOSED SQ.FT. TOTAL 4,759 SQ.FT. FLOOR AREA SUMMARY (E) FIRST FLOOR A+B+C+D 2,249 SQ.FT. (E) FIRST FLOOR +15' CEILING F+G+H 546 SQ.FT. (E) GARAGE +E 633 SQ.FT. (E) SECOND FLOOR +J 1,069 SQ.FT. TOTAL (E) HOUSE 4,497 SQ.FT. ALLOWABLE FLOOR AREA 4,128 SQ.FT. PROPOSED 4,759 SQ.FT. DATE: 11-22-2016 (E) SITE COVERAGE FIRST FLOOR (REFER TO DIAGRAM 3/A2.4) A+B+C+D+E 2,882 SQ.FT. (E) CONCRETE DRIVEWAY/ PATH/ PATIO 2,770 SQ.FT. (E) DECK 50% 670 335 SQ.FT. (E) POOL 1,000 SQ.FT. TOTAL 6,987 SQ.FT. PROPOSED SITE COVERAGE FIRST FLOOR (REFER TO DIAGRAM 3/A2.4) A+B+C+D+E 2,882 SQ.FT. (N) CONCRETE DRIVEWAY/ PATH/ PATIO 3,117 SQ.FT. (N) DECK 50% 610 305 SQ.FT. (E) POOL 1,000 SQ.FT. TOTAL 7,304 SQ.FT. ALLOWABLE SITE COVERAGE 55 % OF 23,654 = 13,010 SQ.FT. Gross Lot Size: 42,878 S.F./ .976 ACRES Front Yard Right of Way: 368 S.F. Santa Clara Valley Water District Easement: 18,839 S.F. Net Lot Size: 23,671 S.F. Average Slope: 20.29% = 21% 15-12.085 Allowable Floor Area Net size reduction based on slope: 30% + 3% = 33% reduction. 23,671 square feet less 7,811.4 square feet = 15,859.57 square feet adjusted Net Site Area. Round up to 16,000 square feet: For lots between 15,000 and 40,000 square feet: 4,050 square feet and 78 square feet for each 1,000 square feet over 15,000… Total =’s: 4,050 + 78 = 4,128 square feet allowable. Scope of Work: This project consists of the modernization of an existing 2-story residence including a first floor addition of 3 s.f.. and a second floor addition of 636 s.f. within the perimeter of the existing residence. There are no proposed changes to the perimeter of the residence. Removal of double height spaces to lower floor area, new hardscape at the pool area, redesigned front entry, new standing seam metal roof, stucco walls and new aluminum windows and doors, along with misc. interior improvements. 1 01-24-2017 1 1 127 6'-8" 2'-6" 6'-8" 6'-0"6'-8"8'-0"6'-8"6'-0"6'-8"2'-8"6'-8"8'-0"6'-8"2'-0"Sill 1'-11"4'-10 1/4"9'-11 1/2"Sill 1'-11"4'-10 1/4" 9'-11 1/2" Sill 1'-11"4'-10 1/4"9'-11 1/2"Sill 2'-10"3'-10 1/4" 4'-6 1/2"Sill 5'-4 1/2"5'-10 1/4" 1'-10 1/2"Sill 4'2'-11 1/4"2'-11 1/2"Sill 4'2'-11 1/4"2'-11 1/2"Sill 4'2'-11 1/4"2'-11 1/2"Sill 1'-4"5'-10 1/4"1'-10 1/2"Sill 1'-4"5'-10 1/4"1'-10 1/2"Sill 1'-4"5'-10 1/4"1'-10 1/2"Sill 11"5'-10 1/4"1'-10 1/2"Sill 11"5'-10 1/4"1'-10 1/2"Sill 11"5'-10 1/4"1'-10 1/2"LIVING ROOM LOWER MASTER SUITE LOWER MASTER SUITE BATHROOM LOWER MASTER SUITE CLOSET ENTRYSTEP UP DINING ROOM KITCHEN FAMILY ROOM STEPSTEPMECH. LAUNDRY POWDER ROOM STORAGE DN GARAGE WATER ELECGASREPLACE STAIRS NO SCOOPE OF WORK Sill 1'-10"4'-10 1/4"6'-11 1/2"Sill 1'-10"4'-10 1/4"4'-10 1/2"Sill 1'-10"4'-10 1/4"4'-10 1/2"Sill 3'-10"2'-10 1/4"4'-10 1/2"Sill 3'-10"2'-10 1/4"4'-10 1/2"Sill 3'-10"2'-10 1/4"2'-10 1/2"Sill 3'-10"2'-10 1/4"4'-10 1/2"BEDROOM 1 BEDROOM 2 MASTER OPEN TO BELOW DN D2 6'-8"2'-8"D5 6'-8"9'-6"102 Sill 3'-6"3'-2"9'-0"D6 6'-8"8'-0"Sill 4'-10"5'-4" 1'-11" D4 6'-8"8'-0"103 Sill 0"6'-8"5'-10"D3 6'-8"2'-0"ROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160AROCKWOOD@ROCKWOO DDESIGN.NET DRAWN BY: LORENA PEREZA1.0SCALE 3/16" = 1'-0"M O N G A _ D U R G I A R E S I D E N C E2 (E) SECOND FLOOR 1 (E) FIRST FLOOR SCALE 3/16" = 1'-0" SCALE 3/16" = 1'-0" 4 SECOND FLOOR DEMO PLAN DATE: 11-22-20161 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .3 SCALE 3/16" = 1'-0"FIRST FLOOR DEMO PLAN 128 D2 6'-8"2'-8"D5 6'-8"9'-6"102 Sill 3'-6"3'-2"9'-0"D6 6'-8"8'-0"101Sill 4'-10"5'-4" 1'-11" D1 8'-0"6'-0"104Sill 0"6'-8" 10'-0"107Sill 0"6'-8" 2'-6"D76'-8" 7'-6" 110 Sill 0"6'-8"8'-0"105 Sill 0"6'-8"10'-0"106 Sill 0"6'-8"6'-6"D4 6'-8"8'-0"103 Sill 0"6'-8"5'-10"D3 6'-8"2'-0"108Sill 5'-2"1'-6" 3'-0"109Sill 2'-10"3'-10" 4'-6"D96'-8" 2'-6"D86'-9" 1'-10" (E) LIVING ROOM (N) 9'-1" CEILING LOWER MASTER SUITE VAULTED CEILING LOWER MASTER SUITE BATHROOM 8'-0" CEILING LOWER MASTER SUITE CLOSET 8'-0" CEILING ENTRY VAULTED CEILINGSTEP UP (E) DINING ROOM 8'-0" CEILING (N) KITCHEN 8'-0" CEILING (E) FAMILY ROOM 8'-5" CEILING STEPSTEP(E) MECH. (E) LAUNDRY (E) POWDER ROOM (E) STORAGE DN (E) GARAGE WATER ELECGASBENCH4'GATEGATE PLANTERPLANTERSTEPPLANTER (E) FIREPLACE PLANTERPLANTER PLANTERPLANTER(N) DECK (N) CONCRETE/ COPING (N) GARAGE DOOR A AB BCC(N) SECOND FLOOR LINE (E) SINKDISH (E) COOKTOP & HOODNEWLOCATIONREF(N) PANTRY(N)MICRO.(N) OVEN (N) ISLAND ROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZA1.1 SCALE 1/4" = 1'-0" M O N G A _ D U R G I A R E S I D E N C E 1 FIRST FLOOR 1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .DATE: 11-22-2016 129 209 Sill 0"6'-8"7'-0"207 Sill 5'-2"1'-6"2'-6"208 Sill 0"6'-8"2'-6"202 Sill 5'-2"1'-6"4'-0"201 Sill 0"6'-8"7'-0"204 Sill 0"6'-8"7'-0"203 Sill 5'-2"1'-6"4'-0"206 Sill 0"6'-8"10'-0"205 Sill 0"6'-8"2'-6"8'-0"x6'-8"7'-0"x6'-8"2'-4"x6'-8"2'-8"x6'-8"2'-8"x6'-8"2'-8"x6'-8"214 Sill 0"6'-8"6'-6"212Sill 0"6'-8" 7'-6"211Sill 0"6'-8" 2'-6"215Sill 0"6'-8" 7'-6"216Sill 0"6'-8" 2'-6"217Sill 0"6'-8" 4'-0" 210 Sill 1'-6"5'-6"8'-0"2'-8"x6'-8"2'-4"x6'-8"2'-4"x6'-8"7'-0"x6'-8"2'-4"x6'-8" 2'-6"x6'-8"2'-6"x6'-8"213 Sill 0"6'-8"10'-0"31/2"12'-91/2"31/2"5'-1"31/2"5'-1"31/2"15'-111/2"31/2"31/2"4'-2"31/2"8'-0"31/2"12'-51/2"31/2"31/2"12'-51/2"31/2"12'-51/2"31/2"31/2"8'-10"31/2"31/2"10'-1"31/2"2'-1"31/2"10'-51/2"31/2"31/2"23'-10"31/2"15'-8"31/2"17'-91/2"31/2"21'-81/2"31/2"31/2"24'-81/4"31/2"31/2"3'-41/2"31/2"2'-11"31/2"5'-5"31/2"12'-1"31/2"31/2"25'-21/2"31/2"OPEN TO BELOW VAULTED CEILING BEDROOM 1 9'-0" CEILINGBEDROOM 2 9'-0" CEILING SITTING AREA 9'-0" CEILING DN NEW GUARDRAIL BATHROOM 2 8'-0" CEILING BATHROOM 1 8'-0" CEILING BEDROOM 3 9'-0" CEILING MASTER BEDROOM VAULTED CEILING MASTER CLOSET VAULTED CEILINGBATHROOMCLOSET STEPSTEPSTEPA AB BCCACCESS TO (E) ATTIC ?8'-0" CEILING LINE8'-0" CEILING LINE 8'-0" CEILING LINE 8'-0" CEILING LINE BATHROOM 3 8'-0" CEILING (N) FIREPLACE 4'-21/4"13'-83/4"(N) RAIN CHANNEL LOCATION NEW ENTRY ROOF PARAPET(N) SKYLIGHTNEW ROOF SECOND FLOOR ADDITIONSLOPE2:12SLOPE4:12SLOPE4:12SLOPE4:12SLOPE4:12SLOPE4:12(E) FIREPLACE SLOPE4:12NEW ROOFA A BCBC(N) SKYLIGHT (N) SKYLIGHT (N) SKYLIGHT (N) SKYLIGHT(N) SKYLIGHT(N) SKYLIGHTSLOPE4:12SLOPE4:12SLOPE4:12SLOPE4:12SLOPE4:12SLOPE4:12(E) FIREPLACE (E) FIREPLACE A BCBCROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZA1.2 SCALE 1/8" = 1'-0"2 (E) ROOF PLAN 1 PROPOSED SECOND FLOOR SCALE 1/8" = 1'-0" SCALE 1/4" = 1'-0" 3 PROPOSED ROOF PLAN M O N G A _ D U R G I A R E S I D E N C E 1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .DATE: 11-22-2016 130 9'-0"1'-6"26'-0"24'-4"25'-11"(N) ENTRY CEILING STOCCO SECOND FLOOR FAMILY ROOM 451.60' 201 102 202 204 103 203 D1 PROPOSED SECOND FLOOR ADDITION 110 452.00' ENTRY 452.43' LIVING/ GUEST ROOM SECOND FLOOR (E) ROOF HIGHT 450.89' (E) FINISH GRADE MAX HEIGHT PROPOSED MAX.EXISTINGGARAGE 448.49' 448.13' (E) FINISH GRADE 449.51'' AVG. GRADEMAX.(E) SIDING TO BE PAINT 104 212 448.30' (E) FINISH GRADE GARAGE 448.49' SECOND FLOOR 452.00' ENTRY9'-0"5 3/16"24'-4"26'-0"452.00' ENTRY 452.43' LIVING/ GUEST ROOM SECOND FLOOR FAMILY ROOM 451.60' GARAGE 448.49' (E) ROOF HIGHT 450.89' (E) FINISH GRADE MAX HEIGHT 448.13' (E) FINISH GRADE 449.51'' AVG. GRADE SECOND FLOOR 448.30' (E) FINISH GRADE GARAGE 448.49' 452.00' ENTRY (N) OPENING ADITTION (E) PAINT SIDING (N) NEW STUCCO W/ TROWER FINISH ALL (E) ROOF & NEW ROOF TO BE STANDING SEAM METAL ROOF/ FLAT ROOF TPO EAST ELEVATION WEST ELEVATION SOUTH ELEVATIONNORTH ELEVATIONROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZA2.1SCALE 1/4" = 1'-0"M O N G A _ D U R G I A R E S I D E N C E3 (E) SIDE NORTH ELEVATION 1 (E) FRONT EAST ELEVATION 2 PROPOSED FRONT EAST ELEVATION 4 PROPOSED SIDE NORTH ELEVATION SCALE 1/4" = 1'-0" SCALE 1/4" = 1'-0"1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .SCALE 1/4" = 1'-0" LOWEST ELEV. POINT AT BUILDING EDGE FROM N.GRADE 448.13' HIGHEST ELEV. POINT AT BUILDING EDGE FROM N.GRADE 450.89' AVERAGE ELEV. POINT 449.51' TOP MOST ELEV. POINT FROM AVERAGE GRADE TO THE ROOF EXISTING ROOF 24'-4" PROPOSED ROOF 25'-11" DATE: 11-22-2016 131 STUCCO CEILING D2 D3 D4 D5 D6 205 206 208 210 105 106 207 213 214 FAMILY ROOM 451.60' PROPOSED SECOND FLOOR ADDITION 452.00' ENTRY 452.43' LIVING/ GUEST ROOM (E) ROOF HIGHT 450.89' (E) FINISH GRADE MAX HEIGHT SECOND FLOOR 448.13' (E) FINISH GRADE 449.51'' AVG. GRADE 209 D7107 D8 D9 109 215 216 217 PROPOSED SECOND FLOOR ADDITION 452.00' ENTRY 452.43' LIVING/ GUEST ROOM SECOND FLOOR (E) ROOF HIGHT 450.89' (E) FINISH GRADE MAX HEIGHT 108 GARAGE 448.80' 452.00' ENTRY 452.43' LIVING/ GUEST ROOM (E) ROOF HIGHT 450.89' (E) FINISH GRADE SECOND FLOOR 448.13' (E) FINISH GRADE LIVING/ GUEST ROOM 452.43' (E) ROOF HIGHT (N) OPENING ADITTION (E) PAINT SIDING (N) NEW STUCCO W/ TROWER FINISH ALL (E) ROOF & NEW ROOF TO BE STANDING SEAM METAL ROOF/ FLAT ROOF TPO EAST ELEVATION WEST ELEVATION SOUTH ELEVATIONNORTH ELEVATIONROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZA2.2SCALE 1/4" = 1'-0"3 (E) SIDE SOUTH ELEVATION 1 (E) REAR WEST ELEVATION 2 PROPOSED REAR WEST ELEVATION 4 PROPOSED SIDE SOUTH ELEVATIONSCALE 1/4" = 1'-0" SCALE 1/4" = 1'-0" SCALE 1/4" = 1'-0"M O N G A _ D U R G I A R E S I D E N C E1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .DATE: 11-22-2016 132 11'-21/2"9'-0"8'-0"1'-0"(E) LIVING ROOM (E) ENTRY (E) DINING ROOM UPSTAIRS SITTING AREA BEDROOM 3 (E) FAMILY ROOM (N) MASTER BEDROOM FAMILY ROOM 451.60' PROPOSED SECOND FLOOR ADDITION 452.43' LIVING/ GUEST ROOM SECOND FLOOR (E) ROOF HIGHT 450.89' (E) FINISH GRADE 448.30' (E) FINISH GRADE GARAGE 448.49'12'-1"16'-6"4'-6"15'-0"9'-03/4"9'-03/4"12'-0"8'-0"26'-0"25'-11"11'-0"4'-10"6'-7"15' HEIGHT CEILING LINE PROPOSED SECOND FLOOR ADDITION 452.43' LIVING/ GUEST ROOM SECOND FLOOR (E) ROOF HIGHT 450.89' (E) FINISH GRADE MAX HEIGHT (E) GUEST BEDROOM (E) LIVING ROOM (N) MASTER BEDROOM(N) MASTER CLOSET 448.13' (E) FINISH GRADE 449.51'' AVG. GRADE8'-0"1'-0"8'-0"(E) ENTRY (E) DINING ROOM (E) GARAGE FAMILY ROOM 451.60' UPSTAIRS SITTING AREA 452.43' LIVING/ GUEST ROOM 450.89' (E) FINISH GRADE 448.30' (E) FINISH GRADE GARAGE 448.49'12'-1"11'-91/2"15'-0"15'-01/4"10'-23/4"9'-41/4" 15' HEIGHT CEILING LINE 452.43' LIVING/ GUEST ROOM (E) ROOF HIGHT 450.89' (E) FINISH GRADE (E) GUEST BEDROOM (E) LIVING ROOM A B C ROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZA2.3SCALE 1/4" = 1'-0"M O N G A _ D U R G I A R E S I D E N C E3 (E) CROSS SECTION B 1 (E) LONG SECTION _A 2 PROPOSED LONG SECTION _A SCALE 1/4" = 1'-0" SCALE 1/4" = 1'-0" SCALE 1/4" = 1'-0"4 PROPOSED CROSS SECTION _B 1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .DATE: 11-22-2016 133 15'-0"9'-43/4"9'-6"1'-0"8'-53/4"10'-71/2"15' HEIGHT CEILING LINE 452.00' ENTRY PROPOSED SECOND FLOOR ADDITION 452.43' LIVING/ GUEST ROOM SECOND FLOOR (E) ROOF HIGHT MAX HEIGHT ENTRY15'-81/4"16'-5"15'-0"15' HEIGHT CEILING LINE 452.00' ENTRY 452.43' LIVING/ GUEST ROOM SECOND FLOOR (E) ROOF HIGHT MAX HEIGHT ENTRY A B C A_976 SQ.FT. E_633 SQ.FT. B_312 SQ.FT. C_437 SQ.FT. D_524 SQ.FT. F_222 SQ.FT. G_147 SQ.FT. H_177 SQ.FT. CEILING +15'-0" CEILING +15'-0" CEILING +15'-0" J_1,069 SQ.FT. K_717 SQ.FT. L_(-) 369 SQ.FT. M_(-) 86 SQ.FT. FROM CEILING +15'-0" AT FIRST FLOOR FROM CEILING +15'-0" AT FIRST FLOOR ADDITION (E) SECOND FLOOR ROCKWOOD DESIGN 3 HIGH SCHOOL COURT LOS GATOS CA. 95030 408-354-2160 AROCKWOOD@ROCKWOODDESIGN.NET DRAWN BY: LORENA PEREZA2.4 SCALE 1/4" = 1'-0"1 (E) CROSS SECTION _C SCALE 1/4" = 1'-0"1 PROPOSED CROSS SECTION _C M O N G A _ D U R G I A R E S I D E N C E1 4 2 5 3 W O R D E N W A Y S A R A T O G A , C A .DATE: 11-22-2016 SCALE 3/32" = 1'-0"3 SQ.FT. DIAGRAM FIRST FLOOR SQ.FT. DIAGRAM SECOND FLOOR SQ.FT. DIAGRAM 1 01-24-2017 134