HomeMy WebLinkAbout02-11-15 Planning Commission Agenda PacketTable of Contents
Agenda 3
January 14, 2015
Draft Minutes 5
Application PDR14-0023; 0 Via Alto Ct (389-27-045); Sakai /
Shimizu - The applicant is proposing a single-story 3,638 square
foot residence that would include a two-car garage and second
dwelling unit. The project would be no taller than 19.5 feet.
There are no protected trees are being proposed for removal.
The net site is 16,146 sq. ft. and the property is zoned for R-1-
12,500. Staff Contact: Michael Fossati (408) 868-1212.
Staff Report - 0 Via Alto 7
Att 1 Resolution 13
Att 2 Front Fence Rendering 18
Att 3 Neighbor Notification 19
Att 4 Landscape Rendering 21
Att 5 Plans Exhibit A 27
Application PDR14-0022 - FER14-0003; 0 Pierce Road (503-18-
002); Hong / Tang - The applicant is proposing a new 24.3 foot
tall single-story 4,711 square foot home that would include a two
-car garage and second dwelling unit. The project also includes
a fence exception to allow an seven foot wood fence acting as a
soundwall in the front along Saratoga-Sunnyvale Road and
portion of exterior side setback along Pierce Road. Planning
Commission design review is required because the project
consists of a new single-story residence over 18 feet in height
and a fence taller than three feet within the required exterior
side setback. Nine protected trees are being proposed for
removal. Staff Contact: Michael Fossati, (408)868-1212
Staff Report - 0 Pierce Road 38
Att 1 Resolution 46
Att 2 Arborist Report 53
Att 3 Neighbor Notification 61
Att 4 Additional Comments 67
Att 5 Story Pole Certification 69
Att 6 Color Front Elevation 70
Att 7 Plans Exhibit A 71
Application PDR14-0016 / CUP14-0004 / SUB14-0002; 12260
Saratoga-Sunnyvale Road / 386-30-035; West Valley Muslim
Association; The applicant is requesting Design Review,
Conditional Use Permit, and Subdivision approval for the
construction of one 2,297 square feet commercial / retail
building that is 20 feet in height and twelve residential
townhomes, each approximately 2,400 square feet in size and
27 feet in height, totaling approximately 34,000 square feet. The
project is in conformance with City standards for height,
setbacks, floor area, and site coverage. The site is1.20 acres in
size and is zoned CV. Staff Contact: Christopher Riordan
(408)868-1235.
Staff Report 77
1
Attachment 1 - Resolution 78
Attachment 2 - Gateway Guidelines Conformance Table 85
Attachment 3 - Story Pole Certification 91
Attachment 4 - CalGreen Checklist 92
Attachment 5 - Neighbor Comments 98
Attachment 6 - Notice of Public Hearing 102
Attachment 7 - Project Plans 109
2
AGENDA
REGULAR MEETING
SARATOGA PLANNING COMMISSION
Wednesday, February 11, 2015
REGULAR MEETING – 7:00 P.M. – CIVIC THEATER/COUNCIL CHAMBERS AT 13777
FRUITVALE AVENUE
PLEDGE OF ALLEGIANCE
ROLL CALL
APPROVAL OF MINUTES
Action Minutes from the Regular Planning Commission Meeting of January 14, 2015
COMMUNICATIONS FROM COMMISSION & PUBLIC
Oral Communications on Non-Agendized Items
Any member of the Public will be allowed to address the Planning Commission for up to three (3) minutes on matters
not on this agenda. The law generally prohibits the Planning Commission from discussing or taking action on such
items. However, the Planning Commission may instruct staff accordingly regarding Oral Communications under
Planning Commission direction to Staff.
REPORT OF APPEAL RIGHTS
If you wish to appeal any decision on this Agenda, you may file an “Appeal Application” with the City Clerk
within fifteen (15) calendar days of the date of the decision.
NEW BUSINESS
PUBLIC HEARING
All interested persons may appear and be heard at the above time and place. Applicants and their representatives
have a total of ten minutes maximum for opening statements. Members of the Public may comment on any item for
up to three minutes. Applicants and their representatives have a total of five minutes maximum for closing
statements.
1. Application PDR14-0023; 0 Via Alto Ct (389-27-045); Sakai / Shimizu - The applicant is proposing a
single-story 3,638 square foot residence that would include a two-car garage and second dwelling unit. The
project would be no taller than 19.5 feet. There are no protected trees are being proposed for removal. The
net site is 16,146 sq. ft. and the property is zoned for R-1-12,500. Staff Contact: Michael Fossati (408)
868-1212.
Recommended action:
Adopt Resolution No. 15-002 approving the project subject to conditions of approval.
2. Application PDR14-0022 - FER14-0003; 0 Pierce Road (503-18-002); Hong / Tang - The applicant is
proposing a new 24.3 foot tall single-story 4,711 square foot home that would include a two-car garage and
second dwelling unit. The project also includes a fence exception to allow an seven foot wood fence acting
as a soundwall in the front along Saratoga-Sunnyvale Road and portion of exterior side setback along
Pierce Road. Planning Commission design review is required because the project consists of a new single-
story residence over 18 feet in height and a fence taller than three feet within the required exterior side
3
setback. Nine protected trees are being proposed for removal. Staff Contact: Michael Fossati, (408)868-
1212.
Recommended action:
Adopt Resolution No. 15-001 approving the project subject to conditions of approval.
3. Application PDR14-0016 / CUP14-0004 / SUB14-0002; 12260 Saratoga-Sunnyvale Road / 386-30-035;
West Valley Muslim Association; The applicant is requesting Design Review, Conditional Use Permit, and
Subdivision approval for the construction of one 2,297 square feet commercial / retail building that is 20
feet in height and twelve residential townhomes, each approximately 2,400 square feet in size and 27 feet in
height, totaling approximately 34,000 square feet. The project is in conformance with City standards for
height, setbacks, floor area, and site coverage. The site is1.20 acres in size and is zoned CV. Staff Contact:
Christopher Riordan (408)868-1235.
Recommended action:
Approve Resolution No. 15-004 approving the project subject to conditions of approval.
PLANNING STAFF/COMMISSION COMMUNICATION
ADJOURNMENT
CERTIFICATE OF POSTING OF AGENDA
I, Abby Ayende, Office Specialist III for the City of Saratoga, declare that the foregoing agenda for the meeting of
the Planning Commission was posted and available for public review on February 5, 2015 at the City of Saratoga,
13777 Fruitvale Ave., Saratoga, CA 95070 and on the City’s website at www.saratoga.ca.us.
You can also sign up to receive email notifications when Commission agendas and minutes have been added
to the City at website http://www.saratoga.ca.us/contact/email_subscriptions.asp.
NOTE: To view previous Planning Commission meetings anytime, go the City Video Archives at
www.saratoga.ca.us
4
ACTION MINUTES
REGULAR MEETING
SARATOGA PLANNING COMMISSION
Wednesday, January 14, 2015
REGULAR MEETING – 7:00 P.M. – CIVIC THEATER/COUNCIL CHAMBERS AT 13777
FRUITVALE AVENUE
ROLL CALL
PRESENT Commissioners Leonard Almalech, Wendy Chang, Kookie Fitzsimmons, Tina
Walia, Acting Chair Pragati Grover
ABSENT Dede Smullen
ALSO PRESENT Kate Bear, Arborist
Christopher Riordan, Senior Planner
Curtis Williams, Interim Community Development Director
COMMUNICATIONS FROM COMMISSION & PUBLIC
APPROVAL OF MINUTES
Approve Action Minutes from the Regular Planning Commission Meeting of December 10, 2014
Action:
WALIA/ALMALECH MOVED TO APPROVE THE DECEMBER 10, 2014 MINUTES. MOTION
PASSED. AYES: ALMALECH, CHANG, FITZSIMMONS, GROVER, WALIA. NOES: NONE.
ABSENT: SMULLEN. ABSTAIN: NONE.
PUBLIC HEARINGS
1. Application CUP13-0002 - 19127 Cox Avenue (386-22-009) Brookside Club of Saratoga - The applicant is
requesting a new use permit to replace their existing use permit, last amended in 1996. The current use
permit includes conditions regarding parking space requirements and hours of operation, for example.
Details of the application can be reviewed at City Hall during normal business hours. The City of Saratoga
will be closed for the Holidays and staff furlough between December 24 2014 and January 4, 2015. The
application can be reviewed during normal business hours beginning January 5, 2015. Staff Contact:
Cynthia McCormick (408)868-1230.
Action:
ALMALECH/WALIA MOVED TO CANCEL THE PUBLIC HEARING FOR THIS
PROJECT. MOTION PASSED. AYES: ALMALECH, CHANG, FITZSIMMONS, GROVER,
WALIA. NOES: NONE. ABSENT: SMULLEN. ABSTAIN: NONE.
2. Application PDR11-0003 & VAR11-0001; 21794 Heber Way (503-31-067); Eric Keng / Steve Sheng –
The project is a Design Review and Variance to construct a new two-story residence with a three-car
garage on a hillside lot. The height will be no taller than 26 feet from average grade. The variance is
required because the applicant is proposing a 97 foot front setback (when 131 foot setback is required) and
a 20 foot and 30 foot side setback (when a 45 foot side setback is required). No protected trees are being
proposed for removal. This meeting is continued from the September 24, 2014 Planning Commission
Meeting. Staff Contact: Michael Fossati (408) 868-1212.
5
Action:
CHANG/ALMALECH MOVED TO CONTINUE THE HEARING TO A DATE
UNCERTAIN. MOTION PASSED. AYES: ALMALECH, CHANG, FITZSIMMONS,
GROVER, WALIA. NOES: NONE. ABSENT: SMULLEN. ABSTAIN: NONE.
3. Application PDR14-0022 - FER14-0003; 0 Pierce Road (503-18-002); Hong / Tang - The applicant is
proposing a new 25 foot tall single-story 4,711 square foot home that would include a two-car garage and
second dwelling unit. The project also includes a fence exception to allow an eight foot soundwall in the
front along Saratoga-Sunnyvale Road and portion of exterior side setback along Pierce Road. Planning
Commission design review is required because the project consists of a new single-story residence over 18
feet in height and a wall taller than three feet within the required exterior side setback. Nine protected trees
are being proposed for removal. Staff Contact: Michael Fossati, (408)868-1212
Action:
ALMALECH/WALIA MOVED TO CONTINUE THE HEARING TO FEBRUARY 11, 2015.
MOTION PASSED. AYES: ALMALECH, CHANG, FITZSIMMONS, GROVER, WALIA.
NOES: NONE. ABSENT: SMULLEN. ABSTAIN: NONE.
4. Application APTR14-0002 – 21901 Mt. Eden Road (503-13-133); Bawa – The owner of the property is
appealing the partial denial of a tree removal permit application (TRP14-0378). The owner applied to
remove 14 oaks on their property. Following inspection, two coast live oaks were approved for removal,
and the remaining twelve oaks were denied based on an inspection by the City Arborist and the
determination that they did not meet the criteria requiring their removal. Staff contact: Kate Bear (408)
868-1276.
Action:
ALMALECH/CHANG MOVED TO ADOPT RESOLUTION 15-0002 DENYING THE
APPEAL. MOTION PASSED. AYES: ALMALECH, CHANG, FITZSIMMONS, GROVER,
WALIA. NOES: NONE. ABSENT: SMULLEN. ABSTAIN: NONE.
DIRECTOR/COMMISSION COMMUNICATION
Senior Planner Christopher Riordan announced the new Community Development Director Erwin
Ordoñez will start January 20, 2015.
The Commission cancelled the January 28, 2015 meeting.
Commissioner Grover invited the Commission to attend the City Council Annual retreat on January 23,
2015.
ADJOURNMENT
WALIA/ALMALECH MOVED TO ADJOURN AT 7:34 PM. MOTION PASSED. AYES:
ALMALECH, CHANG, FITZSIMMONS, GROVER, WALIA. NOES: NONE. ABSENT: SMULLEN.
ABSTAIN: NONE.
6
REPORT TO
THE PLANNING COMMISSION
Meeting Date: February 11, 2015
Application: PDR14-0023
Location / APN: Vacant Lot behind 18771 Allendale Ave. / 389-27-045
Owner/Applicant: Shimizu / Sakai
Staff Planner: Michael Fossati, Planner
0 Via Alto Ct. (APN 389-027-045)
Page 1 of 6
7
Summary
PROJECT DESCRIPTION: The applicant is proposing a one-story, 3,638 sq. ft. residence located on a
vacant lot behind 18771 Allendale Avenue and along Via Alto Court. The residence includes a 671
sq. ft. garage and 650 sq. ft. second dwelling unit, which are both attached to the main residence.
The height of the main residence will be no taller than 19.5 feet. No protected trees are proposed
for removal.
STAFF RECOMMENDATION: Adopt Resolution No. 15-002 approving the project subject to
conditions of approval.
Design review approval is required pursuant to City Code Section 15-45.060.
PROJECT DATA:
Site Area: 16,146 gross / net
Average Slope: +/- 2%
Grading: +/- 20 cy of cut and fill
General Plan Designation: Medium Density Residential (M-12.5)
Zoning: Single-Family Residential (R1-12,500)
Proposed Allowed/Required
Site Coverage
Main House / Garage
Walkways / Decks
Swimming Pool
Paver Driveway
Paver Walkway/Patio
Total Site Coverage
Front Yard Impervious
5,634.7 sf
211.8 sf
995.2 sf
718.7 sf (50% of 1,437.3)
581.2 sf (50% of 1,162.3)
8,151.6 sf (50.5%)
981.5 sf (39.0%)
8,880.3 sf (55%)
1,256 sf (50% of 2,513 sf )
Floor Area
Main House, Garage
& 2nd Dwelling Unit
Total Floor Area
3,638 sf
3,638 sf
4,206 sf
Height
Lowest Elevation Point:
Highest Elevation Point:
Average Elevation Point:
Proposed Topmost Point:
304.2’
306.2’
305.2’
324.7’(19’ 6”)
26 feet Maximum
Application PDR14-0023 0 Via Alto /389-27-045 Page 2 of 6
8
Proposed Allowed/Required
Setbacks
Front:
Left Side:
Right Side:
Rear:
1st Story
25.2’
15.2’
10.3’
25.3’
1st Story
25’
10’
10’
25’
PROJECT DESCRIPTION/DISCUSSION
DESIGN REVIEW
Site and Neighborhood Description: The 16,164 sq. ft. vacant property is located on Via Alto
Court, behind 18771 Allendale Avenue, which is located on the corner of Allendale Avenue and
Via Alto Court. The property is referred to as “0 Via Alto Court” because it has no existing
structure on-site. Properties without structures do not have addresses. The parcel was created from
a subdivision that occurred in 2013. The residential neighborhood includes both single-story ranch
style homes and residences.
Architectural Design: The single story home follows an Japanese influence architectural theme.
The low profile residence includes a mixture of exteriors that include steel troweled cement
plaster and cement fiber shiplap siding. The columns are made of wood with the bottom portion
wrapped in lightweight Eldorado stone veneer. The side facing garage would be a bronze
anodized aluminum garage door with tempered glazing picture windows. The proposed roof is
asphalt comp shingle with painted metal gutters underneath. The proposed colors are as follows:
Front Yard Fence: The applicant has proposed a stain grade wood privacy fence in western cedar
at the front of the property. The design of the fence is four feet, two and half inches of solid fence
and one foot, nine inches of open wood lattice. This fence would be 25 feet from the front property
line, which is parallel to Via Alto Court. The fence would attach to the side of the garage and
provide access to a small front yard through a pedestrian gate. The fence location and height would
not require a fence exception and is permitted per City Code. A rendering of the fence details can
be found as Attachment 2.
Automobile Gate: The applicant has also proposed folding-garage gate that would allow vehicular
access to the main residence and garage. The gate, also located 25 feet away from the property line,
would be constructed with a steel frame and composite infill with a design identical to the wooden
fence.
Detail Colors and Materials
Exterior Stucco Toffee Cream (Benjamin Moore) Stucco
Exterior Siding Beige (Hardieplank) Lap Siding
Stone Veneer Yukon Mountain Ledge (Eldorado Stone) Veneer
Garage Door Bronze (Clopay Avante TM Collection)
Roof Shadow Gray (Certainteed Presidential TL) Shingle
Application PDR14-0023 0 Via Alto /389-27-045 Page 3 of 6
9
Landscaping: The landscape theme is “Japanese Garden”. The largest tree to be planted would
be a Blenhiem apricot tree, as a reminder of the old orchard that once covered the three acres of
property his parents once owned along Allendale Avenue and Via Alto Court. The front
landscaping includes Japanese Black Pine and Maple trees, azalea shrubs, Mondo grass. A
major feature of the front landscape is a dry river of gravel that ties the trees, shrubs and
perennials together. A rendering of the front landscape can be seen as Attachment 3.
Trees: Although an arborist report was included by the applicant, there are no protected trees
being proposed for removal. All trees being proposed for removal are not considered protected
trees per the City Code.
CalGreen Standards/Sustainable Features: The project would comply with the required
Calgreen standards. Additionally, the home would include numerous sustainable features,
including but not limited to, reusing of existing material, orientation of building to optimize solar
energy, installation of an electric vehicle charging station, radiant floor heating, and ENERGY
STAR appliances.
Second Dwelling Unit: The applicant has proposed an attached second dwelling unit at the front of
the residence. The unit is in compliance with all the development standards of City Code, such as
unit size, zoning regulations, parking and access.
Neighbor Notification and Correspondence: The applicant has submitted one neighbor
notification form (Attachment 4). The neighbor demonstrated concerns regarding the height,
direction the home is facing, and the proposed fence.
Staff spoke directly with the neighbor regarding their concerns and informed them the proposed
height is allowed per City Code, and due to orientation and location of the site, does not seem to
unreasonably impact views or privacy of adjacent properties, therefore meeting one of the
findings for approval.
Staff reassured the neighbor that the front door is facing Via Alto, not Allendale Drive as they
stated. Furthermore, Staff informed the neighbor that the proposed fence would be setback 25
feet from the front property line, allowing the front landscaping and proposed trees to buffer the
impact from the public right-of-way.
A public notice was sent to property owners within 500 feet of the site. Staff has spoken with
various property owners from Via Alto Court regarding the proposal, but no additional letters or e-
mails have been received regarding the project.
Application PDR14-0023 0 Via Alto /389-27-045 Page 4 of 6
10
FINDINGS
Design Review Findings:
The Planning Commission may grant Design Review approval pursuant to City Code Article 15-45,
if the Planning Commission makes all of the following findings:
(a) Site development follows the natural contours of the site, minimizes grading, and is
appropriate given the property’s natural constraints. The project meets this finding because
the residence has been proposed within the center of the site. The site will need minimal
grading to develop since the property has a natural level grade.
(b) All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If
constraints exist on the property, the number of protected trees, heritage trees, and native
trees approved for removal shall be reduced to an absolute minimum. Removal of any
smaller oak trees deemed to be in good health by the City Arborist shall be minimized
using the criteria set forth in Section 15-50.080. The project meets this finding because no
protected trees are being removed.
(c) The height of the structure, its location on the site, and its architectural elements are
designed to avoid unreasonable impacts to the privacy of adjoining properties and to
community viewsheds. The project meets this finding because the home has been designed as
a single-story structure. The applicant has exceeded setback requirements of City Code and
maintained a reasonable amount of open area on the property. Both techniques assist in
creating lesser impacts to privacy of adjoining neighbors.
(d) The overall mass and the height of the structure, and its architectural elements are in scale
with the structure itself and with the neighborhood. The project meets this finding because
the even though the height is taller than the majority of homes along Via Alto, the roof plan,
hip design and similar roof lines in the area. The mass of the structure has been lessened by
the proposed exterior finishes, earth tone colors, and increased setbacks from side properties.
(e) The landscape design minimizes hardscape in the front setback area and contains
elements that are complementary to the neighborhood streetscape. The project meets this
finding because the landscape plan will include trees, shrubs, and ground cover that is
complimentary to the properties along Via Alto Court. Even though the front landscaping
isn’t traditional, it is still complimentary to the surroundings due to its simplicity and natural
elements.
(f) Development of the site does not unreasonably impair the ability of adjoining properties to
utilize solar energy. The project meets this finding because the project has chosen a site
location that exceeds the required setback and a roof form that is low in profile. Both of
these factors assist in not impairing the ability of adjoining properties to utilize solar energy.
(g) The design of the structure and the site development plan is consistent with the Residential
Design Handbook, pursuant to Section 15-45.055. The project meets this finding because
Application PDR14-0023 0 Via Alto /389-27-045 Page 5 of 6
11
the building design and site plan incorporate several techniques from the Residential Design
Handbook, including that the height of the structure, its location on the site, and its
architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining
properties and to community viewsheds, the project design is simple with well-proportioned
massing, the project deemphasizes the garage presence from the street, and the project will
maintain the generally established front yard setbacks along the street.
(h) On hillside lots, the location and the design of the structure avoid unreasonable impacts to
ridgelines, significant hillside features, community viewsheds, and is in compliance with
Section 15-13.100. The finding is not applicable as the site is not a hillside lot.
Environmental Determination: The project is categorically exempt from the California
Environmental Quality Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New
Construction or Conversion of Small Structures,” of the Public Resources Code (CEQA). This
exemption allows for the construction of up to three single-family residences and no exception to
that exemption applies.
ATTACHMENTS:
1. Resolution of Approval
2. Front Fence Rendering
3. Front Landscaping Rendering
4. Neighbor Notification Forms
5. Development Plans (Exhibit "A")
Application PDR14-0023 0 Via Alto /389-27-045 Page 6 of 6
12
RESOLUTION NO. 15-003
A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION
FOR DESIGN REVIEW NO. PDR14-0023 APPROVING A NEW ONE-STORY
RESIDENCE LOCATED AT 0 VIA ALTO (APN 389-27-045)
WHEREAS, an application was submitted by Eiko and Bruce Shimuzu, in order to build
a new 3,638 sq. ft., 19.5 foot tall, one-story residence located on a vacant lot on Via Alto Court,
behind 18771 Allendale Avenue. Design Review approval is required because the proposed
project is new single-story structure over eighteen feet in height. The foregoing work is
described as the “Project” in this Resolution.
WHEREAS, the Community Development Department completed an environmental
assessment for the project in accordance with the California Environmental Quality Act (CEQA),
and recommends that the Planning Commission determine this project exempt.
WHEREAS, on February 11, 2015, the Planning Commission held a duly noticed public
hearing on the subject application, and considered evidence presented by City staff, the
applicant, and other interested parties.
NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds,
determines and resolves as follows:
Section 1: The recitals set forth above are true and correct and incorporated herein by
reference.
Section 2: The project is categorically exempt from the California Environmental Quality
Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New Construction or Conversion of
Small Structures”, of the Public Resources Code (CEQA). This exemption allows for the
construction of up to three single-family residences and no exception to that exemption applies.
Section 3: The project is consistent with the following Saratoga General Plan Policies:
Land Use Goal 13 which provides that the City shall use the Design Review process to assure
that the new construction and major additions thereto are compatible with the site and the
adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City
shall require that landscaping and site drainage plans be submitted and approved during Design
Review for a residence prior to issuance of permits; Land Use Element Goal 10 which minimizes
the impact of development proposals in hillside areas by requiring visual analyses and
imposition of conditions to prevent or reduce significant visual impacts; and Conservation
Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of
Saratoga by carefully considering the visual impact of new development.
Section 4: The project is consistent with the Saratoga City Code in that the design and
improvements are consistent with the design review findings in that the project’s site
development follows the natural contours of the site, minimizes grading, and is appropriate given
13
Resolution No. 15-003 Page 2
the property's natural constraints; all protected trees shall be preserved, as provided in Article 15-
50 (Tree Regulations) and if constraints exist on the property, the number of protected trees,
heritage trees and native trees approved for removal shall be reduced to an absolute minimum
(there are no protected trees onsite); and the height of the structure, its location on the site, and
its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining
properties and to community view sheds; and the overall mass and the height of the structure,
and its architectural elements are in scale with the structure itself and with the neighborhood; and
the landscape design minimizes hardscape in the front setback area and contains elements that
are complementary to the neighborhood streetscape; and the development of the site does not
unreasonably impair the ability of adjoining properties to utilize solar energy; and the design of
the structure and the site development plan is consistent with the Residential Design Handbook,
pursuant to Section 15-45.055; and that if the project is a hillside lot, that the location and the
design of the structure avoid unreasonable impacts to ridgelines, significant hillside features,
community view sheds, and is in compliance with Section 15-13.100 of the City Code (the site is
not a hillside lot).
Section 5: The project is consistent with the Saratoga City Code in that no protected
trees that meet the criteria established in Section 15-50.080(a) are being removed.
Section 6: The City of Saratoga Planning Commission hereby approves PDR14-0023
located at 0 Via Alto (APN 389-27-045), subject to the above Findings and Conditions of
Approval attached hereto as Exhibit 1.
PASSED AND ADOPTED by the City of Saratoga Planning Commission this 11th day of
February 2015 by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
___________________________________
Pragati Grover
Acting Chair, Planning Commission
14
Resolution No. 15-003 Page 3
EXHIBIT 1
CONDITIONS OF APPROVAL
PDR14-0023
0 VIA ALTO (APN: 389-27-045)
1. All conditions below which are identified as permanent or for which an alternative period of
time for applicability is specified shall run with the land and apply to the landowner’s
successors in interest for such time period. No zoning clearance, or demolition, or grading
permit for this project shall be issued until proof is filed with the city that a certificate of
approval documenting all applicable permanent or other term-specified conditions has been
recorded by the applicant with the Santa Clara County Recorder’s office in form and content
to the satisfaction of the Community Development Director. If a condition is not
“Permanent” or does not have a term specified, it shall remain in effect until the issuance by
the City of Saratoga of a Certificate of Occupancy or its equivalent.
2. The Owner and Applicant will be mailed a statement after the time the Resolution granting
this approval is duly executed, containing a statement of all amounts due to the City in
connection with this application, including all consultant fees (collectively “processing
fees”). THIS APPROVAL OR PERMIT SHALL EXPIRE SIXTY (60) DAYS AFTER
THE DATE SAID NOTICE IS MAILED IF ALL PROCESSING FEES CONTAINED
IN THE NOTICE HAVE NOT BEEN PAID IN FULL. No Zoning Clearance or
Demolition, Grading, or Building Permit may be issued until the City certifies that all
processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is
maintained).
3. The Project shall maintain compliance with all applicable regulations of the State, County,
City and/or other governmental agencies having jurisdiction including, without limitation, the
requirements of the Saratoga Zoning Regulations incorporated herein by this reference.
4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and
hold the City and its officers, officials, boards, commissions, employees, agents and
volunteers harmless from and against:
a. any and all claims, actions or proceedings to attack, set aside, void or annul any
action on the subject application, or any of the proceedings, acts or determinations
taken, done or made prior to said action; and
b. any and all claims, demands, actions, expenses or liabilities arising from or in any
manner relating to the performance of such construction, installation, alteration or
grading work by the Owner and/or Applicant, their successors, or by any person
acting on their behalf.
In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate
agreement containing the details of this required Agreement to Indemnify, Hold harmless and
Defend, which shall be subject to prior approval as to form and content by the City Attorney.
15
Resolution No. 15-003 Page 4
COMMUNITY DEVELOPMENT
5. Compliance with Plans. The development shall be located and constructed to include those
features, and only those features, as shown on the Approved Plans dated January 29, 2015
denominated Exhibit "A". All proposed changes to the Approved Plans must be submitted in
writing with plans showing the changes, including a clouded set of plans highlighting the
changes. Such changes shall be subject to approval in accordance with Condition 3, above.
6. Building Division Submittal. Four (4) sets of complete construction plans shall be
submitted to the Building Division. These plans shall be subject to review and approval by
the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum
include the following:
a. Architectural drawings and other plan sheets consistent with those identified as Exhibit
“A” on file with the Community Development Department and referenced in Condition
No. 5 above;
b. A note shall be included on the site plan stating that no construction equipment or
private vehicles shall be parked or stored within the root zone of any Ordinance-
protected tree on the site;
c. This Resolution printed onto separate construction plan pages; d. A final utility plan that shows location of HVAC mechanical equipment outside of required setback areas; e. A final Drainage and Grading Plan stamped by a registered Civil Engineer combined with the Stormwater Detention Plan; f. A final Landscape and Irrigation Plan; and
g. All additional drawings, plans, maps, reports, and/or materials required by the Building
Division.
7. Lighting. Exterior lighting shall be shielded so as not to shine on adjacent properties or
public right-of-way.
8. Maintenance of Construction Project Sites. Because this Design Review Approval
authorizes a project which requires a Building Permit, compliance with City Code Section
16-75.050 governing maintenance of construction project sites is required.
9. Fences, Walls and Hedges. All fences, walls and hedges not in connection with the
proposed fence exception shall conform to height requirements provided in City Code
Section 15-29.
10. Final Landscaping and Irrigation Plan. The final landscaping and irrigation plan shall
take into account the following:
a. To the extent feasible, landscaping shall be designed and operated to treat storm water
runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that
16
Resolution No. 15-003 Page 5
provide detention of water, plants that are tolerant of saturated soil conditions and
prolong exposure to water shall be specified.
b. To the extent feasible, pest resistant landscaping plants shall be used throughout the
landscaped area, especially along any hardscape area.
c. Plant materials selected shall be appropriate to site specific characteristics such as soil
type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall,
air movement, patterns of land use, ecological consistency and plant interactions to
ensure successful establishment.
d. Pest resistant landscaping plants shall be considered for use throughout the
landscaped area, especially along any hardscape area.
e. Any proposed or required under grounding of utilities shall take into account potential
damage to roots of protected trees
11. Fire Department Requirements. Owner/applicant shall comply with all Fire Department
requirements.
12. Noise and Construction Hours. In order to comply with standards that minimize impacts to
the neighborhood during site preparation and construction, the applicant shall comply with
City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours,
maintenance of the construction site and other requirements stated in these sections.
13. Front yard landscaping. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department. 150% of the estimated cost of the installation of such landscaping shall be provided to the City.
PUBLIC WORKS
14. Encroachment Permit. The applicant (owner) shall obtain an encroachment permit for any
and all improvements in any City right-of-way or City easement prior to commencement of
the work to implement this Design Review.
17
O Via Alto CourtFront Fence Rendering18
19
20
21
22
23
24
25
26
27
28
29
30
PROJECT NO.13-003 REVISION DATE DESCRIPTION2014.07.09DESIGN REVIEW SUBMITTAL2013.10.07OWNER REVISIONS2015.01.26DESIGN REVIEW SUBMITTALSTUDIO S SQUARED ARCHITECTURE, INC.C19 N. 2nd St., Ste. 205San Jose, CA 95113P : (408) 998 - 0983F : (408) 998 - 0982SHIMIZU RESIDENCENEW SINGLE FAMILY RESIDENCE0 VIA ALTO CT., SARATOGA, CABRUCE SHIMIZU"FOR PLANNING APPROVAL ONLY--NOT FOR CONSTRUCTION"EXTERIOR ELEVATIONSA3.031/4"SOUTH ELEVATION (LEFT)21/4"EAST ELEVATION (FENCE REMOVED FOR CLARITY)11/4"EAST ELEVATION (FRONT)--KEYNOTES= NUMBER OF KEYNOTE BELOW#-1/16"KEYPLAN1/A3.02/A3.11/A3.13/A3.02/A3.01 ASPHALT COMP SHINGLE ROOFING, INSTALL PER MANUF. INSTRUCTIONS--MANUF.: CERTAINTEED; STYLE: PRESIDENTIAL TL; COLOR: SHADOW GRAY www.certainteed.com2 LIGHTWEIGHT STONE VENEER (<15 LBS/SF), INSTALL PER MANUF. INSTRUCTIONS--MANUF.: ELDORADO STONE; STYLE: MOUNTAIN LEDGE; COLOR: YUKON www.eldoradostone.com3SKYLIGHT4 FOLDING GARAGE GATE STEEL FRAME WITH COMPOSITE INFILL--SEE LANDSCAPE PLANS5 CLAD (DARK BRONZE) WOOD FRONT DOOR WITH TEMPERED GLAZING6 DARK BRONZE ANODIZED ALUMINUM WINDOW/DOOR 7 PAINTED METAL GUTTER 8 1"X8" STAIN GRADE WOOD TRIM, CLEAR WESTERN RED CEDAR9 WOOD COLUMN, 12" SQUARE SHAFT, 7'-2" OVERALL HEIGHT, STAIN GRADE CORNERBOARD10 STAIN GRADE WOOD SIDING--WESTERN RED CEDAR (CLEAR) WITH CLEAR MATTE SEALER11 STEEL TROWELED IGNITION RESISTANT CEMENT PLASTER SYSTEM (SMOOTH FINISH) - 7/8" CEMENT PLASTER O/ METAL LATH O/ 2 LAYERS GRADE 'D' OR BETTER BUILDING PAPER, 3 COAT SYSTEM 12 BRONZE ANODIZED ALUMINUM GARAGE DOOR WITH TEMPERED GLAZING PICTURE WINDOWS13 EXTERIOR LIGHT, INSTALL PER MANUF. INSTRUCTIONS--MANUF.: HINKLEY LIGHTING; STYLE: ATLANTIS 2 LIGHT OUTDOOR WALL LANTERN 1649TT; COLOR: TITANIUM www.hinkleylighting.com14 SHAPED WOOD BRACKET PAINTED15 STAIN GRADE WOOD FENCE, CLEAR WESTERN RED CEDAR16 OUTDOOR KITCHEN17 WOOD CLAD BI-FOLD/SLIDING DOORS18 PARALLEL LINE 18' ABOVE AVERAGE GRADE AS REQUIRED BY CITY OF SARATOGA19 PARALLEL LINE 26' ABOVE AVERAGE GRADE AS REQUIRED BY CITY OF SARATOGA20 CEMENT FIBER SHIPLAP SIDING JW HARDIE "ARTISAN" SERIES, PAINTED21 STAIN GRADE WOOD WINDOW TRIM, CLEAR WESTERN RED CEDAR19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)+/- 1'-10"9'-0"12'-0"+/- 3'-6"9'-0"5'-7"1'-8"123456781191213141518192082131
PROJECT NO.13-003 REVISION DATE DESCRIPTION2014.07.09DESIGN REVIEW SUBMITTAL2013.10.07OWNER REVISIONS2015.01.26DESIGN REVIEW SUBMITTALSTUDIO S SQUARED ARCHITECTURE, INC.C19 N. 2nd St., Ste. 205San Jose, CA 95113P : (408) 998 - 0983F : (408) 998 - 0982SHIMIZU RESIDENCENEW SINGLE FAMILY RESIDENCE0 VIA ALTO CT., SARATOGA, CABRUCE SHIMIZU"FOR PLANNING APPROVAL ONLY--NOT FOR CONSTRUCTION"EXTERIOR ELEVATIONSA3.121/4"NORTH ELEVATION (RIGHT)11/4"WEST ELEVATION (REAR)--KEYNOTES= NUMBER OF KEYNOTE BELOW#1/A3.02/A3.11/A3.13/A3.02/A3.0-1/16"KEYPLAN1016171 ASPHALT COMP SHINGLE ROOFING, INSTALL PER MANUF. INSTRUCTIONS--MANUF.: CERTAINTEED; STYLE: PRESIDENTIAL TL; COLOR: SHADOW GRAY www.certainteed.com2 LIGHTWEIGHT STONE VENEER (<15 LBS/SF), INSTALL PER MANUF. INSTRUCTIONS--MANUF.: ELDORADO STONE; STYLE: MOUNTAIN LEDGE; COLOR: YUKON www.eldoradostone.com3SKYLIGHT4 FOLDING GARAGE GATE STEEL FRAME WITH COMPOSITE INFILL--SEE LANDSCAPE PLANS5 CLAD (DARK BRONZE) WOOD FRONT DOOR WITH TEMPERED GLAZING6 DARK BRONZE ANODIZED ALUMINUM WINDOW/DOOR 7 PAINTED METAL GUTTER 8 1"X8" STAIN GRADE WOOD TRIM, CLEAR WESTERN RED CEDAR9 WOOD COLUMN, 12" SQUARE SHAFT, 7'-2" OVERALL HEIGHT, STAIN GRADE CORNERBOARD10 STAIN GRADE WOOD SIDING--WESTERN RED CEDAR (CLEAR) WITH CLEAR MATTE SEALER11 STEEL TROWELED IGNITION RESISTANT CEMENT PLASTER SYSTEM (SMOOTH FINISH) - 7/8" CEMENT PLASTER O/ METAL LATH O/ 2 LAYERS GRADE 'D' OR BETTER BUILDING PAPER, 3 COAT SYSTEM 12 BRONZE ANODIZED ALUMINUM GARAGE DOOR WITH TEMPERED GLAZING PICTURE WINDOWS13 EXTERIOR LIGHT, INSTALL PER MANUF. INSTRUCTIONS--MANUF.: HINKLEY LIGHTING; STYLE: ATLANTIS 2 LIGHT OUTDOOR WALL LANTERN 1649TT; COLOR: TITANIUM www.hinkleylighting.com14 SHAPED WOOD BRACKET PAINTED15 STAIN GRADE WOOD FENCE, CLEAR WESTERN RED CEDAR16 OUTDOOR KITCHEN17 WOOD CLAD BI-FOLD/SLIDING DOORS18 PARALLEL LINE 18' ABOVE AVERAGE GRADE AS REQUIRED BY CITY OF SARATOGA19 PARALLEL LINE 26' ABOVE AVERAGE GRADE AS REQUIRED BY CITY OF SARATOGA20 CEMENT FIBER SHIPLAP SIDING JW HARDIE "ARTISAN" SERIES, PAINTED21 STAIN GRADE WOOD WINDOW TRIM, CLEAR WESTERN RED CEDAR19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)32
PROJECT NO.13-003 REVISION DATE DESCRIPTION2014.07.09DESIGN REVIEW SUBMITTAL2013.10.07OWNER REVISIONS2015.01.26DESIGN REVIEW SUBMITTALSTUDIO S SQUARED ARCHITECTURE, INC.C19 N. 2nd St., Ste. 205San Jose, CA 95113P : (408) 998 - 0983F : (408) 998 - 0982SHIMIZU RESIDENCENEW SINGLE FAMILY RESIDENCE0 VIA ALTO CT., SARATOGA, CABRUCE SHIMIZU"FOR PLANNING APPROVAL ONLY--NOT FOR CONSTRUCTION"SECTIONSA5.021/4"SECTION11/4"SECTION--KEYNOTES1/A5.11/A5.02/A5.0= NUMBER OF KEYNOTE BELOW#-1/16"KEYPLAN1/A5.11/A5.02/A5.019'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)GREATROOMDININGGENKANBEDROOM#3BEDROOM#2MASTER BEDROOMDININGPANTRY19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)+/- 1'-10"9'-0"12'-0"+/- 3'-6"9'-0"5'-7"1'-8"12'-0"33
PROJECT NO.13-003 REVISION DATE DESCRIPTION2014.07.09DESIGN REVIEW SUBMITTAL2013.10.07OWNER REVISIONS2015.01.26DESIGN REVIEW SUBMITTALSTUDIO S SQUARED ARCHITECTURE, INC.C19 N. 2nd St., Ste. 205San Jose, CA 95113P : (408) 998 - 0983F : (408) 998 - 0982SHIMIZU RESIDENCENEW SINGLE FAMILY RESIDENCE0 VIA ALTO CT., SARATOGA, CABRUCE SHIMIZU"FOR PLANNING APPROVAL ONLY--NOT FOR CONSTRUCTION"SECTIONSA5.121/4"SECTION11/4"SECTION--KEYNOTES= NUMBER OF KEYNOTE BELOW#-1/16"KEYPLAN1/A5.11/A5.02/A5.0POOLLIVING19'-5" MAX. BUILDING HEIGHT(N) FINISH GRADE(N) FLOOR BOTTOM PLATE (GUEST HOUSE AND GARAGE(N) FLOOR BOTTOM PLATE (MAIN HOUSE)(N) FLOOR TOP PLATE (GUEST HOUSE AND GARAGE)(N) FLOOR TOP PLATE (MAIN HOUSE GREAT ROOM)(N) FLOOR TOP PLATE (MAIN HOUSE BEDROOMS)34
35
36
0 VIA ALTO CT. SARATOGA, CA
SHIMIZU RESIDENCE
849 Jeffry Drive
PLEASANT HILL CA 94523
phone: 925 822 3085
www.thnorton.com
l a n d s c a p e a r c h i t e c t u r e
LANDSCAPE CONCEPT
1/8" = 1'-0"
SHEET 1 of 1
02-21-14
SALTWATER POOL
W/ JACUZZI & BAJA SHELF
MAIN HOUSE
GARAGE
GUEST
HOUSE
ENGAWA
OUTDOOR
KITCHEN RAISED PLANTER
FF: 100.00
STONE WALL, TYPICAL
FIRE PIT
GOOD NEIGHBOR GATE
12:1 RAMP
ENTRY WALK
PRIVACY FENCING
TRI-FOLD VEHICULAR
ENTRY GATE W/ PEDESTRIAN
ACCESS GATE
ENTRY WALK
DRIVEWAY
"CHIP SEAL" AUTO COURT
STONE BANDING
STONES - TO BE PLACED
IN FIELD, TYPICAL
STONES - TO BE PLACED
IN FIELD, TYPICAL
STONE STEPPERS
LAWN AREA
STONE STEPPERS
ENTRY STEPSVIA ALTO COURTREMOVABLE
BATTING CAGE
P.A.
P.A.P.A.
P.A.
P.A.
P.A.
P.A.P.A.P.A.P.A.
FF: 98.00
KOI POND
POOL DECK
P.A.
P.A.
P.A.
P.A.
GRAVEL ACCENT
JAPANESE BLACK PINE
JAPANESE BLACK PINE
JAPANESE BLACK PINE
37
REPORT TO
THE PLANNING COMMISSION
Meeting Date: February 11, 2015
Application: PDR14-0022 / FER14-0003
Location / APN: 0 Pierce Road / 503-18-002
Owner/Applicant: Nina Tang / Tri Hong
Staff Planner: Michael Fossati, Planner
0 Pierce Road
Page 1 of 8
38
Summary
PROJECT DESCRIPTION: The applicant is proposing a new 24 foot tall single-story 4,711 square
foot home that would include a two-car garage and attached second dwelling unit on a vacant lot
located at the intersection of Saratoga-Sunnyvale Road and Pierce Road. The applicant has also
requested a fence exception to allow seven foot high and six foot high wood fencing in front and
along a portion of the exterior side setback. The fence exception is only required for the portion of
the property facing Pierce Road since a fence acting as a soundwall is allowed within the front
setback adjacent to Saratoga-Sunnyvale Road. Nine of the existing 27 trees on the site have been
approved by the City Arborist to be removed, as they are either in conflict with the design or are in
poor health and structure.
STAFF RECOMMENDATION: Adopt Resolution No. 15-001 approving the project subject to
conditions of approval.
Design review approval is required pursuant to City Code Section 15-45.060. Fence Exception
approval is required pursuant to City Code Section 15-29.090.
PROJECT DATA:
Site Area: 22,239 sf gross / 17,132 sf net
Average Slope: 4%
Grading: 90 cy of cut and 90 cy of fill
General Plan Designation: Medium Density Residential (M-12.5)
Zoning: Single-Family Residential (R1-12,500)
Proposed Allowed/Required
Site Coverage
Main House & Garage
Front Porch Area
Front Walkway
Sidewalk & Patios
Paver Driveway
Total Site Coverage
Front Yard Impervious
4,711 sf
119 sf
631 sf
514 sf
830 sf (50% of 1,660)
7,099 sf (41.4%)
2,291 sf (40%)
9,423 sf (55%)
2,638 sf (50% of 5,726 sf )
Floor Area
Main House & Garage
Total Floor Area
4,711 sf
4,711 sf
4,712 sf (4,284 sf + 428 sf for deed
restricted 2nd dwelling unit)
Height
Lowest Elevation Point:
Highest Elevation Point:
Average Elevation Point:
Proposed Topmost Point:
83.4’
87.2’
85.3’
109.55’ (24’3”)
26 feet Maximum
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 2 of 8
39
Proposed Allowed/Required
Setbacks
Front:
Left Side:
Right Side:
Rear:
1st Story
38’
25’
13’
10’
1st Story
25’
25’
10’
10’
PROJECT DESCRIPTION/DISCUSSION
DESIGN REVIEW
Site and Neighborhood Description: The 22,000 sf vacant corner property is located at the
intersection of Saratoga-Sunnyvale Road and Pierce Road. The property is referred to as “0 Pierce
Road” because it has no existing structure on-site. Properties without structures do not have
addresses. The residential neighborhood includes both single-story and two-story homes with
various architectural styles . Across the street from Saratoga-Sunnyvale Road are Argonaut
Shopping Center and Saratoga Oaks Professional and Commercial Office Center.
Architectural Design: The single story home does not follow a specific architectural theme, but
is similar to many new residences within the City. The residence would be 24.25 feet in height.
The exterior materials would include stucco exterior, stucco columns and trim, steel carriage
garage door, wood entry door, and a concrete tile roof. The design includes accents such as a
decorative metal chimney cap, faux vent louvers, and keystones above the windows.
Landscaping: The landscape design includes a drought-tolerant landscape design that includes
Daylilies, Rhododendron, Azaleas, Japanese Anemone, and Pink Muhly. Permeable pavers from
CalStone Paving would be installed for the driveway and walkway areas.
Trees: Nine trees protected by City Code are requested for removal (Attachment 2). The City
Arborist has approved the removal of those trees (eight “Trees of Heaven” and one “Coast Live
Oak). Reasons for removal include, but are not limited to, the condition of the trees with respect
to disease, imminent danger of falling, proximity to existing or proposed structures and
interference with utility services and the necessity to remove the trees because of physical
damage or threatened damage to improvements or impervious surfaces on the property. Staff
Detail Colors and Materials
Exterior & Trim Siesta Tan (Behr) Stucco
Windows Seista Tan (Anderson)
Front Door Rich Brown Stain (Wood)
Garage Door Sandstone (Amarr Oak Summit Collection)
Roof Village Blend (Eagle Bel Air) Concrete Flat Tile
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 3 of 8
40
notes that 17 trees were recommended for removal by the applicant’s arborist, but the applicant
has only applied for nine of those trees to be removed. The applicant will be required to install
tree fencing and place a monetary deposit of $11,400 for the remaining trees, and plant
replacement trees valuing $12,170 for the trees that are proposed to be removed, prior to building
occupancy.
CalGreen Standards/Sustainable Features: The project would comply with the required
Calgreen standards. Additionally, the home would include elective sustainable features,
including but not limited to, incorporating existing mature landscaping with new landscaping,
installation of a radiant barrier within the roof sheathing, insulation that exceeds building standards,
double-pane windows and doors, and energy star appliances.
Second Dwelling Unit: The applicant has proposed an attached second dwelling unit at the rear of
the residence. The unit is in compliance with all the development standards of City Code, with the
exception of the garage requirement. The applicant has proposed to deed restrict the second
dwelling unit to rent to below market rate households. By deed restricting the unit, the garage
requirement may be waived, pursuant to zoning code provisions. The applicant has demonstrated
an off-street parking pad in order to comply with City Code for deed restricted units.
Fence Exception: The applicant has also applied for a fence exception. The proposed fence would
act as a soundwall and would start on the northern portion of the property (adjacent to Saratoga-
Sunnyvale Road) and would run parallel with the property line heading south, around the corner
between Saratoga-Sunnyvale Road and Pierce Road. The fence would then head west parallel to
Pierce Road for an approximately 54 foot run The proposed fence would be setback ten feet from
the right-of-way line adjacent to Saratoga-Sunnyvale Road and setback approximately one foot
from the right-of-way line adjacent to Pierce Road. The fence would be seven feet in height, with an
additional foot of lattice, along Saratoga-Sunnyvale Road and a portion of Pierce Road. As the
grade increases along Pierce Road, the fence height would eventually drop to six feet, with an
additional foot of lattice. The fence would be constructed of wood in a board and batten pattern.
The tall fence would terminate by connecting to a shorter three foot wood fence which would
continue to run parallel with the property line until it stops at the proposed driveway.
Properties along Saratoga-Sunnyvale Road are allowed to install a fence soundwall without a fence
exception. The City required the fence exception because a portion of the fence would run along
Pierce Road and encroach within the exterior side setback. Staff recommends approval of the fence
exception per the findings below, particularly since it serves to reduce sound from the busy street
and would be generally well screened by existing and proposed plantings.
Neighbor Notification and Correspondence: The applicant has submitted six neighbor
notification forms (Attachment 3). On one of those forms, a neighbor had concerns about the
driveway location. Staff has concluded that the location of the proposed driveway is the best
option since it is as far from the intersection of Pierce Road and Saratoga-Sunnyvale Road as
possible. A driveway approach along Saratoga-Sunnyvale Road would be unsafe, due to the
amount of traffic on the main thoroughfare and the proximity to the signalized intersection.
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 4 of 8
41
A public notice was sent to property owners within 500 feet of the site. Staff received two additional
comment letters (Attachment 4) from the property owners at 12848 Pierce Road and 12881 Pierce
Road. The neighbors took issue with the following:
• Building height
• Second Dwelling Unit
• Setback from Pierce Road
• Soundwall height and location
• Tree removal
Staff has summarized the concerns of the neighbors and provided responses below:
Building Height – The applicant had previously applied for a 25 foot tall residence. The
neighbors’ disagree with any height exception for a single-story residence. Staff informed the
neighbors’ that the applicant had not applied for a height exception, because 26 feet is allowed
per code. Yet, in order to address the concerns of the neighbors the applicant revised their design
and lowered the overall height nine inches.
The height was decreased by lowering the wall plate height from 10 feet (previously) to 9 feet, 7
inches in certain areas of the building. This method was used instead of flattening the top of the
roof, which is inconsistent with the policies of the City’s Residential Design Handbook. The
project proposes a hip roof without any flattened areas. Furthermore, only approximately 5% of
the total roof structure is over 22 feet in height.
Second Dwelling Unit - The second dwelling unit being proposed is within the building
envelope, appearing as a single home, as suggested by one neighbor’s comment letter.
Setback from Pierce Road - The residence would be setback from the curb of Pierce Road
between 32 and 65 feet, which allows sufficient turnaround access for the project. Staff spoke
with Public Works on reviewing the potential access of the property via Saratoga-Sunnyvale
Road. Due to the higher traffic volume and location of the traffic signal, the safer option is to
have the residence accessed via Pierce Road, as currently proposed, at an adequate distance from
the intersection.
Soundwall height and location – The applicant had previously submitted a request for an eight
foot stucco soundwall within the front and exterior side setback. Due to the neighbors’ concerns,
the applicant has modified their plans. The applicant has now proposed a seven foot wood fence
with one foot of lattice to act as a soundwall to run parallel to the Saratoga-Sunnyvale Road and
a portion of Pierce Road. It’s the hope of the applicant that the modification addresses the
concerns of the neighbor while provides the applicant with a sound buffer, but with a softer
appearance of the wood fence in lieu of concrete. Furthermore, the applicant has included
drought-tolerant shrubs and plants along the outer portion of the fence, to break up the mass of
the fence from the public right-of-way view. Staff has included a conditional of approval that
requires the property owner file a Landscape Maintenance Agreement with the City to maintain
the proposed landscaping.
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 5 of 8
42
Tree Removals - No trees in the public right-of-way are proposed for removal. The site
contains over 27 trees. Nine of those trees are to be removed because they are either directly
within the building footprint or are in poor health and structure, as demonstrated in the arborist
report. This information has been discussed with the neighbors after their letters were received.
It should be noted that the comments received were based on the first design. To date, Staff has
not received any additional comments regarding the resubmitted project.
FINDINGS
Design Review Findings:
The Planning Commission may grant Design Review approval pursuant to City Code Article 15-45,
if the Planning Commission makes all of the following findings:
(a) Site development follows the natural contours of the site, minimizes grading, and is
appropriate given the property’s natural constraints. The project meets this finding because
the residence has been proposed on the western portion of the lot, which is the flattest area of
the site. The eastern area, closest to Saratoga-Sunnyvale Road, has a steeper slope, and
therefore is not appropriate in order to minimize grading and visibility.
(b) All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If
constraints exist on the property, the number of protected trees, heritage trees, and native
trees approved for removal shall be reduced to an absolute minimum. Removal of any
smaller oak trees deemed to be in good health by the City Arborist shall be minimized
using the criteria set forth in Section 15-50.080. The project meets this finding in that the
applicant has designed the project to retain the maximum amount of trees possible while
utilizing and enjoying the property for development when there is no other feasible
alternative to the removal. Although the project arborist determined 17 trees met the criteria
for removal, per Saratoga City Code, the applicant has only proposed to remove 9 trees that
are either in direct conflict with the project location or in poor health and structure. Eight of
the 9 trees are “trees of heaven,” not considered a highly desirable species.
(c) The height of the structure, its location on the site, and its architectural elements are
designed to avoid unreasonable impacts to the privacy of adjoining properties and to
community viewsheds. The project meets this finding because the home has been designed as
a single story structure to minimize privacy and viewshed impacts. The proposed residence
has been setback from both the front and exterior side property lines to decrease the impacts
on community viewsheds from the public right-of-way. The structure height is generally less
than 22 feet, but about 5% of the area is up to 24 feet, 3 inches in height.
(d) The overall mass and the height of the structure, and its architectural elements are in scale
with the structure itself and with the neighborhood. The project meets this finding because
the single-story home has been designed with varying roof lines, the incorporation of eaves
and rooflines that are in scale with the residences along Pierce Road, and the design of
appurtenances that are in proportion to the overall building form and neighborhood.
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 6 of 8
43
(e) The landscape design minimizes hardscape in the front setback area and contains
elements that are complementary to the neighborhood streetscape. The project meets this
finding. The proposed driveway and walkways are permeable to maximize natural drainage.
Existing native landscape would remain in the front setback while new drought-tolerant
landscaping would be introduced within the exterior side setback. A soundwall has been
proposed along a portion of the exterior lot lines that is complementary with other residences
along Saratoga-Sunnyvale and Pierce road.
(f) Development of the site does not unreasonably impair the ability of adjoining properties to
utilize solar energy. The project meets this finding because the proposed location and hip
roof design would not impact solar access for adjacent property located west. All other
properties located north, east and south are substantially setback from the project location
and will be unaffected in regards to solar access.
(g) The design of the structure and the site development plan is consistent with the Residential
Design Handbook, pursuant to Section 15-45.055. The project meets this finding because
the building design and site plan incorporate several techniques from the Residential Design
Handbook, including the avoidance of flattening the top of a sloped roof to accommodate
height limitations, designing wall plane heights and eave heights that are in scale with
adjacent residences, using exterior materials that complement the streetscape, managing the
bulk and mass of a structure to minimize interference of views from the street, and selecting
materials, colors, and details that enhance the architecture in a well-composed, understated
manner.
(h) On hillside lots, the location and the design of the structure avoid unreasonable impacts to
ridgelines, significant hillside features, community viewsheds, and is in compliance with
Section 15-13.100. The finding is not applicable as the site is not a hillside lot.
Fence Exception Findings:
The Planning Commission may grant a fence exception as applied for or in modified form,
pursuant to City Code Article 15-29.090, if the Planning Commission makes all of the following
findings:
(a) The subject fence will be compatible with other similar structures in the neighborhood.
The project meets this finding as the majority of properties along either Saratoga-Sunnyvale
Road or Pierce Road have sound walls or front yard fences that buffer noise and sound from
the adjacent street.
(b) The entirety of the subject fence will be constructed of materials that are of high quality,
exhibit superior craftsmanship, and that are durable. The project meets this finding in that
the requested fence would be constructed of wood in a board and batten design, similar to
fences along Saratoga-Sunnyvale Road.
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 7 of 8
44
(c) The modification will not impair the integrity and character of the neighborhood in which
the fence is located. The project meets this finding in that the wall would continue a theme
currently in effect along Saratoga-Sunnyvale Road. The sound wall would not impair the
integrity or character of the neighborhood because it would be made of high quality materials
that are consistent with the main residence and properties along the main thoroughfare of
Saratoga-Sunnyvale Road. The portion of wall that would continue along Pierce Road would
be significantly setback from the street and would be buffered by existing and proposed
landscaping within the public right-of-way.
(d) The granting of the exception will not be detrimental or injurious to the property, adjacent
neighbors, or improvements in the general vicinity and district in which the property is
located. The project meets this finding because the proposed sound wall is well designed and
located in a manner that is not overbearing or insensitive to the neighboring properties.
(e) The granting of the exception will not create a safety hazard for vehicular, pedestrian or
bicycle traffic and does not obstruct the safe access to and from adjacent properties. The
project meets this finding because the wall is substantially setback from both Saratoga-
Sunnyvale and Pierce Road, allowing the unobstructed access of vehicle, pedestrian or
bicycle traffic currently afforded to the property.
Environmental Determination: The project is categorically exempt from the California
Environmental Quality Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New
Construction or Conversion of Small Structures,” of the Public Resources Code (CEQA). This
exemption allows for the construction of up to three single-family residences and no exception to
that exemption applies.
ATTACHMENTS:
1. Resolution of Approval
2. Arborist Report
3. Neighbor Notification Forms
4. Letters from Neighbors
5. Storypole Certification Letter – 0 Pierce Road
6. Color Elevation
7. Development Plans (Exhibit "A")
Application PDR14-0022/FER14-0003; 0 Pierce Road /503-18-002 Page 8 of 8
45
RESOLUTION NO. 15-001
A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION
FOR DESIGN REVIEW NO. PDR14-0022 AND FER14-0003 APPROVING A NEW ONE-
STORY RESIDENCE AND FENCE EXCEPTION LOCATED AT
0 PIERCE ROAD (APN 503-18-002)
WHEREAS, an application was submitted by Nina Tang and Wei Li, in order to build a
new 4,711 sq. ft., 24.3 foot tall, one-story residence and seven foot wood fence along Saratoga-
Sunnyvale Road and a portion of Pierce Road. Design Review approval is required because the
proposed project is new single-story structure over eighteen feet in height. Fence Exception
approval is required because the application includes a wall over six feet in height in an exterior
side setback area. The foregoing work is described as the “Project” in this Resolution.
WHEREAS, the Community Development Department completed an environmental
assessment for the project in accordance with the California Environmental Quality Act (CEQA),
and recommends that the Planning Commission determine this project exempt.
WHEREAS, on January 14, 2015 & February 11, 2015, the Planning Commission held a
duly noticed public hearing on the subject application, and considered evidence presented by
City staff, the applicant, and other interested parties.
NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds,
determines and resolves as follows:
Section 1: The recitals set forth above are true and correct and incorporated herein by
reference.
Section 2: The project is categorically exempt from the California Environmental Quality
Act (CEQA) pursuant to 14 C.C.R. Section 15303, Class 3 “New Construction or Conversion of
Small Structures” of the Public Resources Code (CEQA). This exemption allows for the
construction of up to three single-family residences and no exception to that exemption applies.
Section 3: The project is consistent with the following Saratoga General Plan Policies:
Land Use Goal 13 which provides that the City shall use the Design Review process to assure
that the new construction and major additions thereto are compatible with the site and the
adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City
shall require that landscaping and site drainage plans be submitted and approved during Design
Review for a residence prior to issuance of permits; Land Use Element Goal 10 which minimizes
the impact of development proposals in hillside areas by requiring visual analyses and
imposition of conditions to prevent or reduce significant visual impacts; and Conservation
Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of
Saratoga by carefully considering the visual impact of new development.
46
Resolution No. 15-001 Page 2
Section 4: The project is consistent with the Saratoga City Code in that the design and
improvements are consistent with the design review findings in that the project’s site
development follows the natural contours of the site, minimizes grading, and is appropriate given
the property's natural constraints; all protected trees shall be preserved, as provided in Article 15-
50 (Tree Regulations) and if constraints exist on the property, the number of protected trees,
heritage trees, and native trees approved for removal shall be reduced to an absolute minimum.
Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be
minimized using the criteria set forth in Section 15-50.080; and the height of the structure, its
location on the site, and its architectural elements are designed to avoid unreasonable impacts to
the privacy of adjoining properties and to community view sheds; and the overall mass and the
height of the structure, and its architectural elements are in scale with the structure itself and with
the neighborhood; and the landscape design minimizes hardscape in the front setback area and
contains elements that are complementary to the neighborhood streetscape; and the development
of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy;
and the design of the structure and the site development plan is consistent with the Residential
Design Handbook, pursuant to Section 15-45.055; and that if the project is a hillside lot, that the
location and the design of the structure avoid unreasonable impacts to ridgelines, significant
hillside features, community view sheds, and is in compliance with Section 15-13.100 of the City
Code (not applicable as this is not a hillside lot).
Section 5: The project is consistent with the Saratoga City Code in that the Planning
Commission may grant an exception to the regulations regarding fences as long as the following
findings can be made, which includes that the subject fence will be compatible with other similar
structures in the neighborhood; the entirety of the subject fence will be constructed of materials
that are of high-quality, exhibit superior craftsmanship, and that are durable; the modification
will not impair the integrity and character of the neighborhood in which the fence is located; that
granting of the exception will not be detrimental or injurious to the property or adjacent
neighbors, or improvements in the general vicinity and district which the property is located; and
the granting of the exception will not create a safety hazard for vehicular, pedestrian or bicycle
traffic and does not obstruct the safe access to and from adjacent properties.
Section 6: The project is consistent with the Saratoga City Code in that nine protected
trees that meet the criteria established in Section 15-50.080(a) are being removed, as determined
by the City Arborist.
Section 7: The City of Saratoga Planning Commission hereby approves PDR14-0022 and
FER14-0003, located at 0 Pierce Road (APN 503-18-002), subject to the above Findings, and
Conditions of Approval attached hereto as Exhibit 1.
PASSED AND ADOPTED by the City of Saratoga Planning Commission this 11th day of
February 2015 by the following vote:
AYES:
NOES:
ABSENT:
47
Resolution No. 15-001 Page 3
ABSTAIN:
___________________________________
Pragati Grover
Acting Chair, Planning Commission
48
Resolution No. 15-001 Page 4
EXHIBIT 1
CONDITIONS OF APPROVAL
PDR14-0022 / FER14-0003
0 PIERCE ROAD (APN: 503-18-002)
1. All conditions below which are identified as permanent or for which an alternative period of
time for applicability is specified shall run with the land and apply to the landowner’s
successors in interest for such time period. No zoning clearance, or demolition, or grading
permit for this project shall be issued until proof is filed with the city that a certificate of
approval documenting all applicable permanent or other term-specified conditions has been
recorded by the applicant with the Santa Clara County Recorder’s office in form and content
to the satisfaction of the Community Development Director. If a condition is not
“Permanent” or does not have a term specified, it shall remain in effect until the issuance by
the City of Saratoga of a Certificate of Occupancy or its equivalent.
2. The Owner and Applicant will be mailed a statement after the time the Resolution granting
this approval is duly executed, containing a statement of all amounts due to the City in
connection with this application, including all consultant fees (collectively “processing
fees”). THIS APPROVAL OR PERMIT SHALL EXPIRE SIXTY (60) DAYS AFTER
THE DATE SAID NOTICE IS MAILED IF ALL PROCESSING FEES CONTAINED
IN THE NOTICE HAVE NOT BEEN PAID IN FULL. No Zoning Clearance or
Demolition, Grading, or Building Permit may be issued until the City certifies that all
processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is
maintained).
3. The Project shall maintain compliance with all applicable regulations of the State, County,
City and/or other governmental agencies having jurisdiction including, without limitation, the
requirements of the Saratoga Zoning Regulations incorporated herein by this reference.
4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and
hold the City and its officers, officials, boards, commissions, employees, agents and
volunteers harmless from and against:
a. any and all claims, actions or proceedings to attack, set aside, void or annul any
action on the subject application, or any of the proceedings, acts or determinations
taken, done or made prior to said action; and
b. any and all claims, demands, actions, expenses or liabilities arising from or in any
manner relating to the performance of such construction, installation, alteration or
grading work by the Owner and/or Applicant, their successors, or by any person
acting on their behalf.
In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate
agreement containing the details of this required Agreement to Indemnify, Hold harmless and
Defend, which shall be subject to prior approval as to form and content by the City Attorney.
49
Resolution No. 15-001 Page 5
COMMUNITY DEVELOPMENT
5. Compliance with Plans. The development shall be located and constructed to include those
features, and only those features, as shown on the Approved Plans dated January 22, 2015
denominated Exhibit "A". All proposed changes to the Approved Plans must be submitted in
writing with plans showing the changes, including a clouded set of plans highlighting the
changes. Such changes shall be subject to approval in accordance with Condition 3, above.
6. Building Division Submittal. Four (4) sets of complete construction plans shall be
submitted to the Building Division. These plans shall be subject to review and approval by
the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum
include the following:
a. Architectural drawings and other plan sheets consistent with those identified as Exhibit
“A” on file with the Community Development Department and referenced in Condition
No. 5 above;
b. A note shall be included on the site plan stating that no construction equipment or
private vehicles shall be parked or stored within the root zone of any Ordinance-
protected tree on the site;
c. This Resolution printed onto separate construction plan pages; d. A final utility plan that shows location of HVAC mechanical equipment outside of required setback areas; e. A final Drainage and Grading Plan stamped by a registered Civil Engineer combined with the above-required Stormwater Detention Plan; f. A final Landscape and Irrigation Plan; and
g. All additional drawings, plans, maps, reports, and/or materials required by the Building
Division.
7. Lighting. Exterior lighting shall be shielded so as not to shine on adjacent properties or
public right-of-way.
8. Maintenance of Construction Project Sites. Because this Design Review Approval
authorizes a project which requires a Building Permit, compliance with City Code Section
16-75.050 governing maintenance of construction project sites is required.
9. Fences, Walls and Hedges. All fences, walls and hedges not in connection with the
proposed fence exception shall conform to height requirements provided in City Code
Section 15-29.
10. Final Landscaping and Irrigation Plan. The final landscaping and irrigation plan shall
take into account the following:
a. To the extent feasible, landscaping shall be designed and operated to treat storm water
runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that
50
Resolution No. 15-001 Page 6
provide detention of water, plants that are tolerant of saturated soil conditions and
prolong exposure to water shall be specified.
b. To the extent feasible, pest resistant landscaping plants shall be used throughout the
landscaped area, especially along any hardscape area.
c. Plant materials selected shall be appropriate to site specific characteristics such as soil
type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall,
air movement, patterns of land use, ecological consistency and plant interactions to
ensure successful establishment.
d. Pest resistant landscaping plants shall be considered for use throughout the
landscaped area, especially along any hardscape area.
e. Any proposed or required under grounding of utilities shall take into account potential
damage to roots of protected trees
11. Fire Department Requirements. Owner/applicant shall comply with all Fire Department
requirements.
12. Noise and Construction Hours. In order to comply with standards that minimize impacts to
the neighborhood during site preparation and construction, the applicant shall comply with
City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours,
maintenance of the construction site and other requirements stated in these sections.
13. Front yard landscaping. Front yard landscaping shall be installed prior to final inspection
or a bond satisfactory to the Community Development Department valued at 150% of the
estimated cost of the installation of such landscaping shall be provided to the City.
14. Second Dwelling Unit - Deed Restricted. The owner shall restrict the rental of the second
unit to only households that qualify as lower, very-low, or extremely-low income households
as those terms are defined in the move recent Santa Clara County Housing and Urban
Development Program Income Limits or, in the event that the most recent such report is more
than five years old, in accordance with the definitions set forth in Health and Safety Code
sections 50079.5,50105, and 50106 as those sections exist as of the effective date of this
restriction. "Rental" means any agreement whereby the occupant(s) of the second unit make
any payment in consideration of said occupancy. THIS CONDITION IS PERMANENT.
15. Landscape Maintenance. The applicant shall landscape and permanently maintain an area
parallel to and along the entire exterior side of the wall facing both Saratoga-Sunnyvale Road
and Pierce Road. Prior to issuance of the building permit, a landscape maintenance
agreement shall be executed by the applicant and recorded in the office of the County
Recorder, which agreement shall constitute a covenant running with the land. THIS
CONDITION IS PERMANENT.
CITY ARBORIST
16. Arborist Report. All recommendations of the Arborist Report dated September 30, 2014
and all other future updated reports, and incorporated herein by this reference shall be
followed and incorporated (in its entirety) into the plans.
51
Resolution No. 15-001 Page 7
PUBLIC WORKS
17. Encroachment Permit. The applicant (owner) shall obtain an encroachment permit for any
and all improvements in any City right-of-way or City easement prior to commencement of
the work to implement this Design Review.
52
Community Development Department
City of Saratoga
13777 Fruitvale Avenue
Saratoga, California 95070
ARBORIST REPORT
Application No. ARB14-0040
Prepared by Kate Bear, City Arborist Site: 0 Pierce Road
Phone: (408) 868-1276 Owner: Nina Tang
Email: kbear@saratoga.ca.us APN: 503-18-002
Email:ninatang@yahoo.com
Report History:
Report 1
Date:
Plans received August 26, 2014
Report completed September 30, 2014
PROJECT SCOPE:
The applicant has submitted plans to the City to build a new single story house with attached garage
on a vacant lot.
Nine trees protected by City Code are requested for removal. All meet the criteria allowing their
removal and replacement as part of the project.
STATUS: Approved by City Arborist to proceed with planning and building review, with
attached conditions.
PROJECT DATA IN BRIEF:
Tree bond – Required - $11,400
For trees 1 – 3, 6, 17, 18 and 21 – 23.
Tree fencing – Required – See Conditions of Approval and attached map.
Tree removals – Trees 4, 5, 14, 19, 20, and 24 – 27 are permitted for removal
with building division permit.
Replacement trees – Required = $12,170.
For trees 4, 5, 14, 19, 20, and 24 – 27.
FINDINGS:
Tree Removals
Whenever a tree is requested for removal as part of a project, certain findings must be made and
specific tree removal criteria met. Nine trees protected by City Code (4, 5, 14, 19, 20, and 24 – 27)
are recommended for removal due to their poor health or structure. They meet the City’s criteria
allowing them to be removed and replaced as part of the project, once building division permits have
been obtained. Attachment 2 contains the tree removal criteria for reference.
1
53
0 Pierce Road
Table 1: Summary of Tree Removal Criteria that are met
Tree No. Criteria met Criteria not met
4, 5, 14, 19, 20,
and 24 – 27 1, 2, 4, 6, 7, 9 3, 5, 8
Replacement Trees:
The total appraised value of trees 4, 5, 14, 19, 20, and 24 – 27 is $12,170. New trees equal to this
appraised value will be required as a condition of the project. Replacement trees may be planted
anywhere on the property. Replacement values for new trees are listed below.
New Construction
Based on the information provided, and as conditioned, this project complies with the requirements
for the setback of new construction from existing trees under Section 15-50.120 of the City Code.
Tree Preservation Plan
The arborist report submitted by David Babby and dated May 14, 2014, once included in the final set
of plans, satisfies the requirement for a Tree Preservation Plan under Section 15-50.140 of the City
Code. This report shall also be included in the final set of plans on the Tree Preservation sheet.
ATTACHMENTS:
1 – Plans Reviewed
2 – Tree Removal Criteria
3 – Conditions of Approval
4 – Map of Site showing tree locations and protective fencing
Replacement Tree Values:
15 gallon = $150 24 inch box = $500 36 inch box = $1,500
48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000
IMPORTANT
This entire report, including attachments, shall be copied onto a plan
sheet, titled “Tree Preservation”, and included in the final set of plans.
2
54
0 Pierce Road Attachment 1
PLAN REVIEW:
Architectural Plans reviewed:
Preparer: TDH Design
Date of Plans: July 2014
Sheet A-1 Cover Sheet and Site Plan
Sheet L Landscape Plan
Sheet A-2 Floor Plan
Sheet A-4 Elevations and Sections
Civil Plans reviewed:
Preparer: RW Engineering, Inc.
Date of Plans: July 16, 2014
Sheet C-1 Grading and Drainage Plan
TREE DATA:
Preparer: David Babby, Arbor Resources
Date of Arborist Report: May 14, 2014
An arborist report was submitted for this project which inventoried 24 trees protected by
Saratoga City Code. Although 17 trees are recommended for removal in the report, the
applicant has requested the removal of nine. All nine trees were found to have a low
suitability for retention due to poor health, poor structure, or because they are an
undesirable, short-lived, weedy species. Tree protection recommendations were provided
and monetary values of trees were appraised.
The designated Project Arborist for this project will be David Babby, unless otherwise
approved by the City Arborist.
3
55
0 Pierce Road Attachment 2
TREE REMOVAL CRITERIA
Criteria that permit the removal of a protected tree are listed below. This information is from Article
15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If
findings are made that meet the criteria listed below, the tree(s) may be approved for removal and
replacement during construction.
(1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or
proposed structures and interference with utility services, and whether the tree is a Dead tree or a
Fallen tree.
(2) The necessity to remove the tree because of physical damage or threatened damage to improvements
or impervious surfaces on the property.
(3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the
diversion or increased flow of surface waters, particularly on steep slopes.
(4) The number, species, size and location of existing trees in the area and the effect the removal would
have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general
welfare of residents in the area.
(5) The age and number of healthy trees the property is able to support according to good forestry
practices.
(6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the
protected tree.
(7) Whether the approval of the request would be contrary to or in conflict with the general purpose and
intent of this Article.
(8) Any other information relevant to the public health, safety, or general welfare and the purposes of this
ordinance as set forth in Section 15-50.010
(9) The necessity to remove the tree for economic or other enjoyment of the property when there is no
other feasible alternative to the removal.
(10) The necessity to remove the tree for installation and efficient operation of solar panels, subject to the
requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed
and replacement trees planted in conformance with the City Arborist's recommendation.
4
56
0 Pierce Road Attachment 3
CONDITIONS OF APPROVAL
1. It is the responsibility of the owner, architect and contractor to be familiar with the
information in this report and implement the required conditions.
2. The arborist report submitted by David Babby of Arbor Resources and dated May 14, 2014,
shall be copied onto a plan sheet, titled “Tree Preservation” and included in the final set of
plans.
3. All recommendations in the submitted arborist report shall be conditions of approval for the
project.
4. This arborist report shall also be copied on to a plan sheet and included in the final job copy
set of plans.
5. Tree Protection Security Deposit
a. Is required per City Ordinance 15-50.080.
b. Shall be in the amount of $11,400 for tree(s) 1 – 3, 6, 17, 18 and 21 – 23.
c. Shall be obtained by the owner and filed with the Community Development Department
before obtaining Building Division permits.
d. May be in the form of cash, check, credit card payment or a bond.
e. Shall remain in place for the duration of construction of the project.
f. May be released once the project has been completed, inspected and approved by the City
Arborist.
6. Tree Protection Fencing:
a. Shall be installed as shown on the attached map.
b. Shall be established prior to the arrival of construction equipment or materials on site.
c. Shall be comprised of six-foot high chain link fencing mounted on eight-foot tall, 2-inch
diameter galvanized posts, driven 24 inches into the ground and spaced no more than 10
feet apart.
d. Shall be posted with signs saying “TREE PROTECTION FENCE - DO NOT MOVE OR
REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, KATE BEAR (408)
868-1276”.
e. Call City Arborist, Kate Bear at (408) 868-1276 for an inspection of tree protection
fencing once it has been installed. This is required prior to obtaining building division
permits.
f. Tree protection fencing shall remain undisturbed throughout the construction until final
inspection.
g. If contractor feels that work must be done inside the fenced area, call City Arborist to
arrange a field meeting.
7. The designated Project Arborist for this project shall be David Babby, of Arbor Resources
unless otherwise approved by the City Arborist.
8. The Project Arborist shall visit the site every two weeks during grading activities and
monthly thereafter.
5
57
0 Pierce Road Attachment 3
9. The Project Arborist shall be on site to monitor all work within:
a. 7 feet of trees 1 and 6
b. 10 feet of trees 21, 22 and 23
c. 14 feet of trees 17 and 18
10. The Project Arborist shall be on site to monitor installation of the:
a. Gas line at tree 1
b. Stucco wall at trees 1, 17, 18, 21 and 23, specifically placement of piers and beams.
11. Following completion of the work around trees, and before a final inspection of the project,
the applicant shall provide a letter to the City from the Project Arborist. That letter shall
document the work performed around trees, include photos of the work in progress, and
provide information on the condition of the trees.
12. No protected tree authorized for removal or encroachment pursuant to this project may be
removed or encroached upon until the issuance of the applicable permit from the building
division for the approved project.
13. Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for
protecting trees per City Code Article 15-50 on all construction work.
14. All construction activities shall be conducted outside tree protection fencing. These activities
include, but are not necessarily limited to, the following: demolition, grading, trenching,
equipment cleaning, stockpiling and dumping materials (including soil fill), and
equipment/vehicle operation and parking.
15. Any permitted pruning or root pruning of trees on site shall be performed under the
supervision of the Project Arborist and according to ISA standards.
16. Trees 4, 5, 14, 19, 20, and 24 – 27 meet the criteria for removal and may be removed and
replaced once Building Division permits have been obtained.
17. Trees permitted for removal shall be replaced on or off site according to good forestry practices,
and shall provide equivalent value in terms of aesthetic and environmental quality, size, height,
location, appearance and other significant beneficial characteristics of the removed trees. The
value of the removed trees shall be calculated in accordance with the ISA Guide for Plant
Appraisal.
18. New trees equal to $12,170 shall be planted as part of the project before final inspection and
occupancy of the new home.
19. Replacement values for new trees are listed below.
15 gallon = $150 24 inch box = $500 36 inch box = $1,500
48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000
20. At least two new trees shall be from 24 inch box containers and reach a height at maturity of 35
feet or more.
6
58
0 Pierce Road Attachment 3
21. The rest of the replacement trees may be of any species and planted anywhere on the
property, as long as they do not encroach on retained trees.
22. Only drought tolerant plants that are compatible with oaks are permitted under the outer half
of the canopy of oak trees on site.
23. Water loving plants and lawns are not permitted under oak tree canopies.
24. At the end of the project, when the contractor wants to remove tree protection fencing and
have the tree protection security deposit released by the City, call City Arborist for a final
inspection.
7
59
1
Attachment 4
Legend
Tree Canopy
Tree Protection
Fencing
0 Pierce Road
2 3
4 5
6
7 8
9
10
11
13
Tree 12 off the bottom left corner
of the map on adjacent property.
14
15
16
17
18
19
20
21
22
23
24
25
26 27
8
60
61
62
63
64
65
66
Please find attached my comments regarding proposed development project PDR14-0022 & FER14-0003 / 0
Pierce Road; APN 503-18-002.
The owner/applicants came by my house in late summer, showed me the initial plans for the house and asked for
my initial comments. At the time, I was not able to review the plans in as much detail as I would have liked but in
general approved of the façade of the house. Since then, the proposed plans appear to have changed, in some
ways substantially.
Building height: The initial proposal presented was for one single-story residence that was within the City’s
height limitations for a single family residence. Given the location of the property and existing residences
surrounding the property, I do not feel that the 25 foot tall exception should be granted. This is a residence
not a commercial building and which sits on a slight rise and is surrounded by single story houses and one
historic house.
Second Dwelling Unit: The initial proposal did not include a second dwelling unit, and I was assured that there
was to be one house not two on the property. I would oppose the construction of a second dwelling unit and
find that a single residence, perhaps with a slightly larger footprint would be more appropriate for the site.
Setback from Pierce Road: The architectural poles recently erected show the residence being much closer to
Pierce Road than the previously proposed plans which showed the structures set further back. I mentioned to
the applicants that access to the property from Pierce Road would be difficult. They said that the plans were
to set the building far enough back to allow for vehicles to turn around within the driveway so that they could
exit facing Pierce rather than backing out. However, the architectural poles seem to have the structure so
close to Pierce as to not allow adequate space for turn-around. For this reason, and because of increased
potential impacts to pedestrians, bicyclists and other drivers, I have strong reservations about the closeness of
the building to Pierce Road.
Sound walls: The property grade at the corner of Pierce and Saratoga-Sunnyvale Road is approximately 4 feet
higher than the road grade. For this reason, I feel that a 7’ sound wall along Saratoga-Sunnyvale Road would
suffice. An 8’ wall coupled with the removal of trees would result in sound bouncing over the proposed
property thus increasing the noise to neighboring properties. As it is, Pierce Road is a very noisy street and
anything adding to the noise is of concern to us.
Sound wall along Pierce Road. I do not agree with the exception to allow an 8’ sound wall along Pierce Road,
however, would not be opposed to a 6’ wall along a portion of the exterior side setback along Pierce from the
intersection with Saratoga-Sunnyvale Road. Installing trees along the perimeter of the property will buffer
the noise and suggest requiring adequate setback and installation of trees or other tall landscaping inside the
walls.
Tree removal: I assume that no trees within the City’s property fronting the site are proposed for removal
and I would be opposed to any removal of the landscaping in the City’s ROW. The owner/applicant mentioned
the removal of only one large Oak tree and I told them of my concerns and that I would not agree with this
tree’s removal suggesting that it may only need to be trimmed and/or cabled. I would like to see this option
explored further. I would also be opposed to the removal of any established oak or redwood trees unless
they are directly within in the building’s footprint. I would like to know the species and location of the other
trees proposed for removal and reserve my comment until I can view the site plans.
I may not be able to attend the public hearing scheduled for January 6th, however, I would like my
comments/concerns entered into the public record for the meeting. Thank you.
Sincerely
Antoinette Romeo
12848 Pierce Road
Saratoga, CA 95070
67
68
RW ENGINEERING, INC.
Civil Engineers · Land Surveyors
505 Altamont Drive, Milpitas, CA 95035
Tel: (408) 262-1899 Fax: (408) 824-5556
Email: rwengineering@gmail.com
January 23, 2015
City of Saratoga – Planning Division
13777 Fruitvale Ave., Saratoga, CA 95070
Re: Story Pole Certification
Project Site: 0 Pierce Road, Saratoga, California
APN: 503-18-002
Dear Sir:
We have surveyed the story poles located at 0 Pierce Road. Based on our survey, I certify that
story poles located on the above-referenced site are in substantial conformance with the design,
height and location shown on the plans submitted for Planning Application.
For additional information, please contact me at (408) 262-1899.
Feel free to contact me if you have any questions.
Sincerely Yours,
Robert Wang, PE, PLS
69
70
71
72
73
74
75
76
REPORT TO THE
PLANNING COMMISSION
Meeting Date: February 11, 2015
Application: Design Review PDR14-0016 / Use Permit
CUP14-0004 / Tentative Map SUB14-0002
Location / APN: 12260 Saratoga-Sunnyvale Road
386-30-035
Owner / Applicant: Anwar Awad / West Valley Muslim Association
Staff Planner: Christopher Riordan
SITE
12260 Saratoga-Sunnyvale Rd.
SUMMARY
ZONING GENERAL PLAN DESIGNATION
Commercial Visitor (CV) Commercial Retail (CR)
PARCEL SIZE
52,311 square feet
PROJECT DESCRIPTION:
The proposed project includes the construction of the following:
• One commercial / retail building, approximately 2,297 sq. ft. in size and 20 feet in height.
• Twelve attached townhomes, each approximately 26 feet in height, with square footages
ranging in size from approximately 2,833 – 2,856 square feet.
The applicant is requesting design review approval for the commercial and residential
buildings, conditional use permit approval for mixed-use development, and tentative map
approval for a subdivision.
STAFF RECOMMENDATION:
Approve Resolution No. 15-004 approving the project subject to conditions of approval.
PROJECT DATA:
The following project data table separates the project into two categories: Category 1 applies
to the commercial building and how it conforms to the prescribed C-V zoning standards and
Category 2 applies to the residential townhouses and how they conform to the prescribed
Residential Multi-Family (R-M) zoning standards.
C-V Zoning (Category 1) Site
Area: 10,230 sq. ft.
Proposed Allowable / Required
Structure Coverage
Building Footprint
TOTAL Site Coverage
2,297 sq. ft.
2,297 sq. ft. (22.4%)
Maximum Allowable
6,138 sq. ft. (60%)
Setbacks
Front (West): 76-0’ 10’
Rear (East): 380-0’ 36’
Left Side (South): 16’-4” 15’-8”
Right Side (North): 16’-1” 15’-8”
2
C-V Zoning (Category 1) Site
Area: 10,230 sq. ft.
Proposed Allowable / Required
Height
99.95’
Maximum Allowable Lowest Elevation Point:
Highest Elevation Point: 99.13’ 119.54’ (20 feet)
Average Elevation Point: 99.54’
Proposed Topmost Point: 119.21’(19’-8”)
R-M Zoning (Category 2) Site
Area: 42,081 sq. ft.
Proposed Allowable / Required
Structure Coverage
Building Footprint
TOTAL Site Coverage
16,713 sq. ft.
16,713 sq. ft. (39.72%)
Maximum Allowable =
16,832 sq. ft. (40%)
Setbacks
Front (West)
Rear (East)
Left (South)
Right (North)
1st Floor
117’-0”
38’-10”
17’-0”
27’-0”
2nd Floor
117’-0”
38’10”
17’-0”
27’-0”
1st Floor
25’-0”
25’-0”
16’-10.5”
16’-10.5”
2nd Floor
25’-0”
25’-0”
16’-10.5”
16’-10.5”
Height (Units 1 – 4)
97.35’
Maximum Height = Lowest Elevation Point:
Highest Elevation Point: 99.06’ 128.205’ (30’)
Average Elevation Point: 98.205
Proposed Topmost Point: 124.625 (26.42’)
Height (Units 5 – 8)
96.75’
Maximum Height = Lowest Elevation Point:
Highest Elevation Point: 97.76’ 127.225’ (30’)
Average Elevation Point: 97.225
Proposed Topmost Point: 123.645’(26.42’)
Height (Units 9 – 12)
96.09’
Maximum Height = Lowest Elevation Point:
Highest Elevation Point: 96.66’ 126.375’ (30’)
Average Elevation Point: 96.375
Proposed Topmost Point: 122.795’ (26.42’)
Per the table above, the proposed project conforms to the building coverage, setback, and
height requirements for the C-V and R-M zoning districts, as required per the Mixed-Use
Development standards.
3
PROJECT APPROVALS
This project includes applications for the following approvals:
Design Review
Pursuant to City Code Section 15-46.020(a)(1), any new structure or structures within a
commercial zoning district requires design review approval from the Planning
Commission. This includes the multi-family residential portion of the project.
Conditional Use Permit
Pursuant to City Code Section 15-19.040(b)(2), any project that includes mixed-use
development requires conditional use permit approval. The applicant has not identified
tenants for the proposed commercial spaces at this time.
Tentative Map
Pursuant to City Code Section 14-20.060, the Planning Commission shall conduct a
public hearing on an application for tentative subdivision approval. The applicant is
requesting a 13-lot residential and commercial subdivision (one parcel for commercial
use and 12 for residential townhomes).
SITE AND PROJECT CHARACTERISTICS
Existing Site Description
Previous uses of the site included light industrial and commercial. All buildings on the site
have been removed with the exception of the concrete foundations. Adjacent uses include
a commercial/residential project which is under construction on the adjacent property to
the north at 12250 Saratoga-Sunnyvale Road. That project is similar to the proposed
project and includes 12 townhomes that are 25’-10” in height and a commercial building at
the front that is 19’-10” in height and was approved by the Planning Commission in
December 2013. The Commission’s approval was appealed by an adjacent neighbor and
the City Council denied the appeal and approved the project in March 2014. Additional
adjacent uses include single family homes to the east and a two story office condominium
building on the property to the south. Commercial businesses are located on the opposite
side of Saratoga-Sunnyvale Road. The site is zoned Commercial - Visitor (C-V) and the
net lot size is approximately 1.20 acres.
Building Design- Commercial Building
The proposed commercial building has been designed to complement existing commercial
structures, and the adjacent commercial building under construction at 12250 Saratoga-
Sunnyvale Road, with respect to building height and architectural features. The front of the
building would include two 17 feet tall entry elements with stone cladding, a stucco exterior
with a 4.5 foot tall stone wainscot and double arched windows at the front and side
elevations. The rear elevation will be stucco and the mansard roof will be covered with
terracotta barrel tiles.
4
Building Design- Residential Building
The exterior of the proposed townhomes would include a stone wainscot and horizontal
fiber-cement siding for the first floor and stucco for the second floor. Architectural projections
would include balconies with wrought iron railings. Additional architectural details would
include wood shutters, exposed wood beams, wood trellises, both square and
arched windows, and low-pitched gabled roofs. The mass of the buildings would be
broken up with varying rooflines, second story architectural projections, and a variety of
exterior materials and colors.
The back elevation of the rear most unit (Unit 12) [sheet A-14 of the development plans)
has been modified to respect the privacy concerns of the adjacent residential neighbors. This
includes both clerestory windows and windows with their lower half obscured. The
balconies on both the north and south elevations include solid walls to minimize casual
views into the adjacent residential properties.
Planning Commission Study Session
The Planning Commission previously reviewed the project during an October 2014 study
session. The Planning Commission was generally supportive of the project and provided the
following project related comments:
• Provide a view study which illustrates the sight lines from the rear townhouse unit to the
adjacent residences;
• The architectural style for the commercial building could be more creative;
• A wall should be constructed along the rear property line which is consistent with the wall that
was required for the adjacent project under construction;
• Consider landscaping to address the privacy impacts on the adjacent residential properties;
• Project lighting should be minimized;
• Landscaping at rear property line should be planted prior to project completion to maximize
opportunity for growth and screening.
During City Council’s review of the adjacent mixed-use project on appeal, the City
Council required that the rear most residential townhome have an increased rear second
story setback to reduce the privacy impact on the adjacent single-family residential
properties. The Planning Commission discussed this during the Study Session and there
was lack of consensus to require this for the subject project because the proposed 38’-10”
second story rear setback for the proposed project exceeds the 30 feet rear second story
setback of the adjacent project prior to City Council review. An exhibit indicating the
sight lines from the proposed project into the rear yards of the adjacent residential
properties is included as Sheet A17 of the Development Plans (Attachment 7).
5
Exterior Materials
Detail Colors and Materials
Building Ext. Commercial
Tan colored stucco
Brown colored “ledgestone”
Residential
Bldgs. 1 & 3 – Dark Tan colored stucco and white colored trim and
windows.
Bldgs. 2 & 4 – Light Tan colored stucco and white colored trim and
windows.
Additional colors include red colored trellises and exposed beams
and black colored wrought iron railings
Windows Commercial
Aluminum storefront windows with black trim
Residential
Vinyl windows with white trim
Roofing Commercial
Terracotta barrel tiles - brown
Residential
Terracotta barrel tiles – blend of brown, red, and tan
Accents /Entry Brown “Eldorado” stone veneer (both buildings)
Saratoga Gateway Design Guidelines
The proposed project is consistent with the objectives and the principles of the Saratoga-
Sunnyvale Road Gateway Design Guidelines (Gateway Guidelines), such as allowing the
incorporation of residential uses to increase diversity in Saratoga’s housing stock (Goal D),
preserving and protecting Saratoga’s pedestrian-friendly environment and enhancing the
quality of life by encouraging Commercial activity in the Gateway districts (Goal A, B), and
promoting and encouraging housing provisions consistent with the General Plan for resident
employees of the City of Saratoga businesses and service providers (Goal D). A table
documenting conformance with the Gateway Guidelines is included as Attachment 2.
Landscaping
A landscape plan for the common areas is included as Sheet L1 of the Development Plans and
represents 4,467 square feet or 8.5% of the project overall site area. This plan indicates that the
three existing Chinese Pistache trees near the front property line between the sidewalk and the
parking lot are to remain. Additional plants in this area would include bushes and flowering
groundcovers.
Landscaping between the buildings would include bushes and trees including Crape Myrtles
and Laurel trees.
6
New landscaping along the rear property line would include the one Yew pine and numerous
shrubs and hedges including Carolina laurel and Pittosporum to enhance the privacy of the
adjacent residential properties. Yew Pines can grow up to 50’ in height and 25’ in width,
while Carolina Laurel and Pittosporum can grow 15 – 20’ in height and 6 – 8’ in width. The
proposed landscape plan does not indicate the existing pine trees located along the rear
property line; however, the applicant intends to maintain these trees and incorporate them into
the project’s overall landscaping. Items which influence placement and variety of the tree
and shrubs include the proposed bio-retention area as well as the utility easements (i.e. power
lines) located across the rear of the site. A condition of approval (#17) has been added to
require coordination of tree protection and an arborist’s report with the City Arborist prior to
building permit submittal.
The applicant has agreed to coordinate with the adjacent property owners located on the
opposite side of the rear property line regarding alternative species of landscaping to satisfy the
privacy request of these neighbors. The applicant has also agreed to install the landscaping in
this area at the earliest possible time prior to project completion. A condition requiring this
coordination with neighboring property owners has been added as a condition of approval.
Parking and Vehicular Access
Access to the site would be from a shared driveway with the adjacent mixed-use project at
12250 Saratoga-Sunnyvale Road that is currently under construction. This driveway is 22
feet wide and would be located along the entire length of the northern property line
separating the two projects. This driveway would provide vehicular access to the proposed
parking spaces for both retail buildings as well as to all the residential parking on both sites
including the enclosed garages. The access easement between the two properties was
recorded prior to the building permit being issued for the adjacent mixed-use project.
The project would require a total of 42 parking spaces. The commercial and residential uses
have separate parking requirements. Parking ratios per City Code are shown below:
• Commercial- One space for each two hundred square feet of floor area.
• Multi-Family Residential - One covered space within a garage for each dwelling unit,
plus one and one-half additional spaces on the site for each dwelling unit.
The retail use requires that the project include 12 parking spaces which would be included in
a parking lot located in front of the retail building adjacent to Saratoga-Sunnyvale Road.
The residential use requires that 30 spaces be provided. This includes 12 spaces within
enclosed garages and an additional 18 spaces on site for residents and guests.
A total of 45 parking spaces are provided on site which includes 12 spaces within enclosed
garages for the residential uses.
The project was reviewed by the City’s Traffic Engineer. The project is estimated to generate
11 a.m. peak hour trips and 15 p.m. peak hour trips which is less than the 25 peak hour trips
necessary to require a Traffic Impact Analysis. The traffic engineer further evaluated the
traffic circulation pattern associated with the proposed project and the cumulative traffic
7
associated with the mixed use project under construction at 12250 Saratoga-Sunnyvale Road
and the existing Saratoga Star Aquatics Swim Center located at 12230 Saratoga-Sunnyvale
Road, and determined that no traffic operational issues or safety concerns associated with the
project are anticipated.
The Traffic Engineer did make the following project related onsite recommendations which
have been incorporated into the conditions of approval.
• The project should include one Class 2 bicycle parking space (Class 2 parking facilities
include bicycle racks to which the frame and at least one wheel can be secured with a
user-provided lock).
• Stop signs should be installed from the parking lot to the shared driveway.
• Include a double yellow center line on the shared driveway from the sidewalk for about
20-25 feet to the parking lot entrances.
Energy Efficiency
Per City Code Section 16-47, all new commercial buildings are required to incorporate
energy efficient or “green” measures into their design. The energy efficient measures
included in the project would include:
• Permeable paving;
• Exceeding California Energy Code requirements by 15%;
• Electric vehicle charging stations for each residential building;
• Energy Star certification for at least 90% of building lighting.
The completed CalGreen Checklist is included as Attachment 4.
Outdoor Open Space
The applicant would include private rear yards for each of the residential uses, which
meets the requirement of private, usable space, per the Mixed-Use Development Standards
within the City Code. The total amount of the site set aside for private open space is 8,336
square feet. Furthermore, the owner shall be required to pay a fee to the City in lieu of
dedicating land for park use. This fee is referred to as a “Park In-Lieu Fee,” and has been
calculated as $20,700 per residential unit.
Neighbor Notification
Public notices for this project were sent to all property owners within 500 feet of the site for
last October’s Planning Commission Study Session and again for the subject public hearing.
Adjacent neighboring property owners attended the October 2014 Study Session and had an
opportunity to review the project and ask questions of the applicant. Staff has exchanged
emails and met with adjacent neighboring property owners on more than one occasion to
discuss the project and to review proposed plans. The public hearing notice and description
of the project was published in the Saratoga News.
Staff did receive project related written comments from tenants of the adjacent two-story office
building located to the south at 12280 Saratoga-Sunnyvale Road which have been included as
Attachment #5. Their concerns are related to the project’s potential impacts on privacy to
8
individual offices and possible loss of sunlight due to shadowing. The comments also included
requested design modifications such as:
- Increased side setback;
- Reduced building mass facing the office building;
- Additional landscaping to provide privacy screening;
- Reduction in the number of windows facing the office building; and
- Modification of the roof design to reduce mass.
Staff believes that the proposed setbacks are consistent with similar adjacencies with office
uses on other properties.
Mixed-Use Development Standards
All mixed-used developments must meet the following standards contained in Article 15-58
of the City Code:
a) The proposed density does not exceed 20 dwelling units per net acre.
b) Only commercial uses may be located on the ground floor abutting a street.
Dwelling units may be located in all other portions of the structure or site.
c) The additional findings can be made for projects where the residential floor area
exceeds 50% of the total floor area of the project. These additional findings can be
found within the Design Review Findings below.
d) The project meets the parking requirement established by City Code.
e) Proposed fencing complies with the maximum height standards.
f) Each dwelling unit has a private, usable outdoor space.
g) The maximum height of a mixed-use structure shall be as it is stated in the
underlying zoning district. There are not mixed-use structures in the project.
h) The overall site coverage is within the coverage limits of the applicable zoning
district.
i) A concrete block wall along the rear property line is proposed which would match
the 8 foot wall that will be constructed as part of the adjacent project at 12250
Saratoga-Sunnyvale Road and new landscape screening that includes trees and
hedges to help protect the privacy of abutting single-family residential land uses.
j) The project is multi-story and has been designed to provide adequate privacy
protection to the adjacent neighbors. Design features include partially obscure glass,
clerestory windows, and screened balconies on the left (rear) elevation of Unit #12.
k) The project applicant will be required to pay a park-in-lieu fee, established pursuant
to Section 14-25.080 of the City Code.
The project applicant has met all of the above requirements.
9
DESIGN REVIEW FINDINGS
The findings required for issuance of a Design Review Approval pursuant to City Code
Section 15-46.040 are set forth below and staff believes that the Applicant has met the
burden of proof to support making all of those required findings:
(a) Where more than one building or structure will be constructed, the architectural
features and landscaping thereof shall be harmonious. Such features include height,
elevations, roofs, material, color and appurtenances. The proposed project includes
structures with similar architectural features such as barrel tile terracotta roofing, wrought
iron railing, wood trellises, and consistent exterior façade finishes such as stucco and stone
details with earth tone colors. The project includes varying roof forms, new landscaping, and
a similar building footprint and height as nearby commercial and residential buildings, both
existing and under construction, located along Saratoga-Sunnyvale Road. These factors help to
create a harmonious affect along the Saratoga Gateway. This finding can be made in the
affirmative.
(b) Where more than one sign will be erected or displayed on the site, the signs shall have
a common or compatible design and locational positions and shall be harmonious in
appearance. The proposal does not include any signage. Future signage will be required to
meet the City sign code requirements and the Saratoga-Sunnyvale Gateway Design
Guidelines. This finding can be made in the affirmative.
(c) Landscaping shall integrate and accommodate existing trees and vegetation to be
preserved; it shall make use of water-conserving plants, materials and irrigation systems
to the maximum extent feasible; and, to the maximum extent feasible, it shall be clustered
in natural appearing groups, as opposed to being placed in rows or regularly spaced.
The proposed landscaping includes a variety of drought tolerant plants, trees and bio
retention turf. Plants have been selected for their variety of color, texture and aesthetics
as illustrated in the proposed landscape plan. This finding can be made in the affirmative.
(d) Colors of wall and roofing materials shall blend with the natural landscape and be
nonreflective. The wall colors and roofing materials would blend with the natural
landscape because the proposed color tones are different shades of browns, beiges and
grays, which are within a similar color spectrum as nearby commercial and residential
properties, both existing and under construction, along Saratoga-Sunnyvale Road. This
finding can be made in the affirmative.
(e) Roofing materials shall be wood shingles, wood shakes, tile, or other materials
such as composition as approved by the Planning Commission. No mechanical
equipment shall be located upon a roof unless it is appropriately screened. The proposed
project would include a barrel tile terracotta roof. The proposed roof is non-reflective and
is a blend of brown and red tones. No rooftop mechanical equipment is proposed that
would be visible from offsite. This finding can be made in the affirmative.
(f) The proposed development shall be compatible in terms of height, bulk and design with
other structures in the immediate area. The proposed project would be compatible
with other developments along Saratoga-Sunnyvale Road. The nearby area is comprised of
two-story commercial and residential structures with similar heights. The adjacent project
10
under construction at 12250 Saratoga Sunnyvale Road is similar to the proposed project in that
it too has a front facing commercial building and twelve two story townhomes at its rear. The
height of the adjacent project is 25’-10” and the proposed project is 26’-5”. This finding can be
made in the affirmative.
Furthermore, the Planning Commission must make the following findings because the
residential floor area exceeds 50 percent of the total floor area of all buildings onsite. The
findings are as follows:
(1) That the proposed location of the mixed-use is in accord with the objectives of the
Zoning Regulations and the purposes of the district in which the site is located. The
proposed location is within a commercial district that allows mixed-use development as a
conditionally permitted use. Furthermore, mixed-use residential development in
commercial zoning districts is consistent with implementation of the General Plan and
Housing Element. This finding can be made in the affirmative.
(2) That the proposed location of the mixed-use and the conditions under which it
would be operated or maintained will not be detrimental to the public health, safety or
welfare, or materially injurious to properties or improvements in the vicinity. The
project includes commercial and residential dwelling units within a commercial zoned
district. The project is similar to mixed-use projects within the immediate area. The
operation and maintenance of either use would not be detrimental to the public health,
safety and welfare of the properties in the vicinity in that both uses are already
established in existing commercial districts.
(3) That the proposed mixed-use will comply with each of the applicable provisions of
this Chapter. This finding can be made because appropriate conditions have been placed
on the proposed conditional use to ensure compliance to City Code requirements. This
finding can be made in the affirmative.
(4) That the proposed mixed-use will not adversely affect existing or anticipated uses in
the immediate neighborhood, and will not adversely affect surrounding properties or
the occupants thereof. This finding can be made because the City currently has multiple
commercial/residential developments within the immediate neighborhood. The project
proposes density and uses similar to nearby properties, most specifically, the property
located across Saratoga-Sunnyvale Road as well as the adjacent project at 12250 Saratoga-
Sunnyvale Road.
CONDITIONAL USE PERMIT FINDINGS
The findings required for issuance of a Conditional Use Permit Approval pursuant to City
Code Section 15-55.070 are set forth below and staff believes that the Applicant has met the
burden of proof to support making all of those required findings:
(a) That the proposed location of the conditional use is in accord with the objectives of
the Zoning Ordinance and the purposes of the district in which the site is located.
This finding can be met because the proposed commercial use and mixed-use residential
11
are both already are existing within the Commercial-Visitor (CV) zoning districts. Both uses
have been evaluated and it has been determined that adequate off-street parking and loading
areas are sufficient. This finding can be made in the affirmative.
(b) That the proposed location of the conditional use and the conditions under which it
would be operated or maintained will not be detrimental to the public health, safety or
welfare, or materially injurious to properties or improvements in the vicinity. This
finding can be met because the project has been reviewed and conditioned by the
required agencies and departments. The proposed development would not be detrimental
to public safety, as it will comply with all applicable local and state regulations. This
finding can be made in the affirmative.
(c) That the proposed conditional use will comply with each of the applicable provisions
of this Chapter. This finding can be made because appropriate conditions have been
placed on the proposed conditional use permit to ensure compliance to City Code
requirements. Any intensification of the proposed conditional use would require an amended
Conditional Use Permit application. This finding can be made in the affirmative.
(d) That the proposed conditional use will not adversely affect existing or anticipated uses
in the immediate neighborhood, and will not adversely affect surrounding properties or
the occupants thereof. This finding can be made because the project has been analyzed for
adverse effects and it has been determined that the project can provide sufficient off-street
parking and will not result in additional traffic impacts, or any additional adverse effects on
existing or anticipated uses. This finding can be made in the affirmative.
ALTERNATIVE STANDARDS FOR MULTI-FAMILY DWELLINGS
When multi-family dwellings are proposed to be located upon a site within the CV
zoning district, the Planning Commission must apply for such dwellings the development
standards set forth in Article 15-19 of the City Code. The density of development shall be
as determined in each case by the Planning Commission, based upon its finding that:
(1) The project will not constitute overbuilding of the site. This finding can be made
because the project has met all zoning requirements associated with the site, such as
setbacks, building height, site coverage, and required off-street parking. This finding can
be made in the affirmative.
(2) The project is compatible with the structures and density of development on
adjacent properties. This finding can be made because the project is consistent with
structures and the development of adjacent properties. For example, the adjacent project
under construction at 12250 Saratoga-Sunnyvale Road has 12 units per acre and is 25’-10”
in height. The project, as proposed, is 12 dwelling units per acre with structures no taller
than 26’-5” in height. This finding can be made in the affirmative.
(3) The project will preserve a sufficient amount of open space on the site. This finding
can be made because the project, as proposed, would dedicate approximately 11% of the
site to landscaping. Furthermore, per City Code Section 14.25.080, the applicant shall pay
12
a fee to the City in lieu of dedicating open space land in the amount of $20,700 per
dwelling unit. This finding can be made in the affirmative.
(4) The project will provide sufficient light and air for the residents of the site and the
occupants of adjacent properties. This finding can be made in the affirmative as the
project, as designed, includes private rear yards for all of the dwelling units. These open
areas would allow the residents of the site sufficient access to light and air.
Furthermore, the applicant has met the setback requirements established by City Code,
which will provide sufficient light and air for occupants of adjacent properties. This
finding can be made in the affirmative.
TENTATIVE MAP FINDINGS
The findings required for issuance of a Tentative Map Approval pursuant to City Code
Section 14-20.070 are set forth below. The Planning Commission shall not approve any
tentative map or building site if the applicant is unable to meet any of the following specific
conditions:
(1) That the proposed map or building site is not consistent with the General Plan and any
applicable specific plan. The proposed map and building site are consistent with the
General Plan and Saratoga-Sunnyvale Road Gateway Guidelines, as the project would
provide the opportunity for offices and service establishments to concentrate for the
convenience of the public and in mutually beneficial relationship to each other while
promoting a stable, attractive mixed use commercial and residential development.
(2) That the design or improvement of the proposed subdivision or building site is not
consistent with the General Plan and any applicable specific plan. The proposed
subdivision has been designed to meet the requirements of Chapter 14 and Chapter 15 of the
City Code, which reflects the policies of the General Plan and Saratoga. The project design
includes commercial and residential uses within a commercial district, which can be
conditionally approved per the City Code.
(3) That the site is not physically suitable for the type of development proposed. The
proposed site is physically suitable for commercial and residential development because the
lot is located within a commercial district and accessible to all required utilities.
(4) That the site is not physically suitable for the proposed density of development. The
proposed site is physically suitable for the proposed density because, per City Code, mixed-
use developments are allowed to have up to 20 units per acre. The adjacent project at
12250 Saratoga-Sunnyvale Road has 12 units per acre.
(5) That the design of the subdivision or building site or the proposed improvements are
likely to cause substantial environmental damage or substantially and avoidably injure
fish or wildlife or their habitat. The proposed project would not cause substantial
environmental damage or substantially and avoidably injure fish or wildlife or their habitat
because the project site is within an urban area and not located near wildlife habitat.
(6) That the design of the subdivision or building site or type of improvements is likely to 13
cause serious public health or safety problems. The design of the subdivision meets all
local requirements and standards and would not cause public health or safety problems.
(7) That the design of the subdivision or building site or type or improvements will conflict
with easements, acquired by the public at large, for access through or use of property
within the proposed subdivision or building site. In this connection, the advisory agency
may grant tentative approval if it finds that alternate easements, for access or for use, will
be provided, and that these will be substantially equivalent to ones previously acquired by
the public. This subsection shall apply only to easements of record or to easements
established by judgment of a court of competent jurisdiction and no authority is hereby
granted to the advisory agency to determine that the public at large has acquired
easements for access through or use of property within the proposed subdivision or
building site. The design of the subdivision would not conflict with existing easements, but
rather, will result in the continuation and beautification of a pedestrian path along
Saratoga-Sunnyvale Road.
(8) That a proposed subdivision of land which is subject to a contract executed pursuant
to the California Land Conservation Act of 1965 (The "Williamson Act") will result in
the creation of parcels of insufficient size to sustain their agricultural use, except as
otherwise provided in Government Code Section 66474.4. The property within the
proposed project is not agricultural land and is not in contract pursuant to the California
Land Conservation Act of 1965, also known as the “Williamson Act”.
(9) That the discharge of waste from the proposed subdivision or building site into an
existing community sewer system would result in violation of existing requirements
prescribed by a State regional water quality control board pursuant to Division 7
(commencing with Section 13000) of the State Water Code. The project includes a
Stormwater Pollution Prevention Plan (SWPPP) that incorporates microdetention in
landscaping, appropriate maintenance and storm drain labeling, and bioretention areas to be
constructed onsite. These site design and source control measures will assist in proper
disposal of waste; therefore the project would not violate the existing requirements
prescribed by the State Regional Water Quality Control Board regarding discharge.
ENVIRONMENTAL DETERMINATION: The project is Categorically Exempt from the
Environmental Quality Act (CEQA) pursuant to Section 15332 of the Public Resources
Code. Section 15332 exempts from environmental review “projects characterized as in-
fill development meeting conditions, such as, conformance with the applicable general
plan designation and all general plan policies, zoning designation, and regulations.” The
project is proposing new construction of one commercial building and twelve residential
buildings (a total of thirteen buildings) all within an urbanized area, consistent with the
general plan, zoning policies and regulations. The project applicant has not requested any
variances or exceptions for the proposed approvals.
ATTACHMENTS:
1. Resolution of Approval – 12260 Saratoga-Sunnyvale Road
2. Gateway Guidelines Consistency Table
3. Story Pole Certification Letter
4. CalGreen Checklist 14
5. Comments from adjacent neighbors
6. Public hearing notice, mailing addresses, and map for project notification
7. Reduced Plans, Exhibit "A”
15
Attachment 1
RESOLUTION NO. 15-004
A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION
APPROVING DESIGN REVIEW (PDR14-0016), CONDITIONAL USE PERMIT (CUP14-
0004), AND TENTATIVE MAP (SUB14-0002) LOCATED AT
12260 SARATOGA-SUNNYVALE ROAD
WHEREAS, an application was submitted by West Valley Muslim Association, which
requests Design Review approval to construct one commercial building and 12 residential
townhomes, Conditional Use Permit approval for mixed-use development within the Commercial-
Visitor (CV) zoning district, and a Tentative Subdivision Map approval to create 12 residential
townhomes. The foregoing work is described as the “Project” in this Resolution; and
WHEREAS, the limits of ownership, whether residential or commercial space, will be
defined on the condominium plan (a part of Covenants, Conditions and Restrictions (CC&R)) that
will be prepared together with the tract map and recorded concurrently for the twelve residential
townhomes; and
WHEREAS, a Maintenance Association will be formed to maintain both land and the
buildings; and
WHEREAS, on February 11, 2015, the Planning Commission held a duly noticed public
hearing on the subject application, and considered evidence presented by City Staff, the applicant,
and other interested parties.
NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds,
determines and resolves as follows:
Section 1: The recitals set forth above are true and correct and incorporated herein by
reference.
Section 2: The project is Categorically Exempt from the Environmental Quality Act
(CEQA) pursuant Section 15332 of the Public Resources Code. Section 15332 allows “projects
characterized as in-fill development meeting conditions, such as, conformance with the applicable
general plan designation and all general plan policies, zoning designation, and regulations”. The
project is proposing new construction of one commercial building and twelve residential buildings
(a total of thirteen buildings), all within an urbanized area, consistent with general plan, zoning
policies and regulations. The project applicant has not requested any variance or exception for the
proposed entitlements.
Section 3: The project is consistent with the Saratoga General Plan Goals LU 2 in that the
City shall encourage the economic viability of Saratoga’s existing commercial and office areas and
their accessibility by residents, taking into account the impact on surrounding residential areas.
Section 4: The project is consistent with the Saratoga City Code regarding Design Review
findings in that the project will incorporate architectural features and landscaping that are
harmonious to the existing commercial neighborhood, in that the landscaping shall integrate water-
78
Resolution No. 15-004
conserving plants, materials and irrigation systems to the maximum extent feasible, in that the
project will incorporate colors of wall and roofing materials to blend with the natural landscape and
be non-reflective, and that the proposed development shall be compatible in terms of height, bulk
and design with other structures in the immediate area.
Section 5: The project is consistent with the Saratoga City Code regarding Conditional Use
Permit findings in that the project location of the conditional use is in accord with the objectives of
the Zoning Ordinance and the purposes of the district in which the site is located, the proposed
location of the conditional use and the conditions under which it would be operated or maintained
will not be detrimental to the public health, safety or welfare, or materially injurious to properties or
improvements in the vicinity, the proposed conditional use will comply with each of the applicable
provisions of Chapter 15 of the Saratoga City Code, and that the proposed conditional use will not
adversely affect existing or anticipated uses in the immediate neighborhood, and will not adversely
affect surrounding properties or the occupants thereof.
Section 6: The City of Saratoga Planning Commission hereby approves applications
PDR14-0016, CUP14-0004, and SUB14-0002, for the project located at 12260 Saratoga-Sunnyvale
Road, subject to the Conditions of Approval attached hereto as Exhibit 1.
PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 11th day of
February 2015 by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
____________________________
Pragati Grover
Chair, Planning Commission
79
Resolution No. 15-004
Exhibit 1
CONDITIONS OF APPROVAL
12260 SARATOGA-SUNNYVALE RD
CONDITIONS OF APPROVAL
A. GENERAL
1. All conditions below which are identified as permanent or for which an alternative period of
time for applicability is specified shall run with the land and apply to the landowner’s
successors in interest for such time period. No zoning clearance, or demolition, or grading for
this project shall be issued until proof is filed with the city that a certificate of approval
documenting all applicable permanent or other term-specified conditions has been recorded by
the applicant with the Santa Clara County Recorder’s office in form and content to the
Community Development Director.
2. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until
the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent.
3. The Owner and Applicant will be mailed a statement, after the time the Resolution granting this
approval is duly executed, containing a statement of all amounts due to the City in connection
with this application, including all consultant fees (collectively “processing fees”). This
approval or permit shall expire sixty (60) days after the date said notice is mailed if all
processing fees contained in the notice have not been paid in full. No Zoning Clearance or
Demolition, Grading, or Building Permit may be issued until the processing fees have been paid
in full (and, for deposit accounts, a surplus balance of $500 is maintained).
4. The Project shall maintain compliance with all applicable regulations of the State, County, City
and/or other governmental agencies having jurisdiction including, without limitation, the
requirements of the Saratoga Zoning Regulations incorporated herein by this reference.
5. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and
hold the City and its officers, officials, boards, commissions, employees, agents and volunteers
harmless from and against:
a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on
the subject application, or any of the proceedings, acts or determinations taken, done or
made prior to said action; and
b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner
relating to the performance of such construction, installation, alteration or grading work by
the Owner and/or Applicant, their successors, or by any person acting on their behalf.
In addition, prior to any Zoning Clearance from the Community Development Director, Owner
and Applicant shall execute a separate agreement containing the details of this required
Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval
as to form and content by the City Attorney.
80
Resolution No. 15-004
COMMUNITY DEVELOPMENT
6. Compliance with Plans. The development shall be located and constructed to include those
features, and only those features, as shown on the Approved Plans dated January 23, 2015
denominated Exhibit "A". All proposed changes to the Approved Plans must be submitted in
writing with plans showing the changes, including a clouded set of plans highlighting the
changes. Such changes shall be subject to approval in accordance with Condition No. 4, above.
7. Building Division Submittal. Four (4) sets of complete construction plans shall be submitted
to the Building Division. These plans shall be subject to review and approval by the City prior to
issuance of Zoning Clearance. The construction plans shall, at a minimum include the
following:
a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A”
on file with the Community Development Department and referenced in Condition No. 6
above;
b. A note shall be included on the site plan stating that no construction equipment or private
vehicles shall be parked or stored within the root zone of any Ordinance-protected tree on
the site;
c. This signed and dated Resolution printed onto separate construction plan pages;
d. All additional drawings, plans, maps, reports, and/or materials required by the Building
Division.
8. Lighting. Exterior lighting shall be shielded so as not to shine on adjacent properties or public
right-of-way.
9. Maintenance of Construction Project Sites. Because this Design Review Approval
authorizes a project which requires a Building Permit, compliance with City Code Section 16-
75.050 governing maintenance of construction project sites is required.
10. Intensification of Medical Use. Any expansion of the conditional uses shall require approval
of an amended Conditional Use Permit.
11. Noise Levels. All noise levels will comply with Saratoga Municipal Code (SMC) Section 7-
30.040 regarding noise standards and SMC Section 7-30.060 regarding exceptions to special
activities.
12. Home Owner’s Association. Prior to Final Map approval, the owner/applicant shall be
required to create and establish an owner’s association or other entity which will be in charge of
operation and maintenance of the project, including the commercial and residential portion, in
perpetuity which would include both the commercial. Furthermore, the owner/applicant will be
required to submit proof, acceptable to the City of Saratoga, that such entity has been
established.
13. Bike Racks. The project should include one Class 2 bicycle parking space (Class 2 parking
facilities include bicycle racks to which the frame and at least one wheel can be secured with
a user-provided lock).
81
Resolution No. 15-004
14. Fencing. A concrete wall shall be installed along the rear property line which is consistent
with the existing concrete wall at 12280 Saratoga-Sunnyvale Road.
15. Site Circulation: Stop signs are to be installed from the parking lot to the shared driveway.
A double yellow line shall be installed at the shared driveway from the sidewalk to the
parking lot entrances.
16. Landscaping: The applicant shall coordinate with the adjacent residential neighbors
regarding the specific selection of shrubs and trees to be planted adjacent to the rear (eastern)
property line for the purpose of enhancing privacy. The agreed upon list of shrubs and trees
shall be approved by the City Arborist and is to be included on the landscape plan submitted
for building permit. The landscaping adjacent the rear property line shall be planted at the
earliest possible time prior to project completion.
17. Final Map: The final map shall be approved and recorded prior to building permit issuance.
CITY ARBORIST
18. Existing Trees. The applicant intends to maintain the existing Chinese Pistache street trees and
the pine trees along the rear (eastern) property line as part of the project. A tree protection plan
and arborist report for these trees shall be reviewed by the City Arborist prior to issuance of
building permits. Any conditions of the Arborist approval related to fees or deposits for tree
protection or replacement shall be met prior to submittal of a building permit or during
construction, as required.
PUBLIC WORKS
19. Property Survey. Prior to submittal of the Final Map to the Public Works Department for
examination, the owner (applicant) shall cause the property to be surveyed by a Licensed
Land Surveyor or an authorized Civil Engineer. The submitted map shall show the existence
of a monument at all external property corner locations, either found or set. The submitted
map shall also show monuments set at each new corner location, angle point, or as directed
by the Public Works Department, all in conformity with the Subdivision Map Act and the
Professional Land Surveyors Act.
20. Submittal Requirements. The owner (applicant) shall submit four (4) copies of a Final Map
in substantial conformance with the approved Tentative Map, along with the additional
documents required by Section 14-40.020 of the Municipal Code, to the Public Works
Department for examination. The Final Map shall contain all of the information required in
Section 14-40.030 of the Municipal Code and shall be accompanied by the following items:
a. One copy of map checking calculations.
b. Preliminary Title Report for the property dated within ninety (90) days of the date of
submittal for the Final Map.
c. One copy of each map referenced on the Final Map.
d. One copy of each document/deed referenced on the Final Map.
82
Resolution No. 15-004
e. One copy of any other map, document, deed, easement or other resource that will
facilitate the examination process as requested by the Public Works Department.
21. Map Checking Fees. The owner (applicant) shall pay a Map Checking fee, as determined
by the Public Works Director, at the time of submittal of the Final Map for examination.
22. Monuments. Interior monuments shall be set at each lot corner either prior to recordation of
the Final Map or some later date to be specified on the Final Map. If the owner (applicant)
chooses to defer the setting of interior monuments to a specified later date, then sufficient
security as determined by the Public Works Director shall be furnished prior to Final Map
approval, to guarantee the setting of interior monuments.
23. Encroachment Permit Requirement. The owner (applicant) shall obtain an Encroachment
Permit from the City of Saratoga for any and all improvements in the City right-of-way or
City easement prior to commencement of the work. The owner (applicant) shall replace
sections of sidewalk and/or curb and gutter as determined during the Encroachment Permit
issuance.
24. Dedication. The owner (applicant) shall provide Irrevocable Offers of Dedication for all
required easements and/or rights-of-way on the Final Map, in substantial conformance with
the approved Tentative Map, prior to Final Map approval. Private Storm Drain Easement(s)
shall be shown on the Final Map for areas with proposed storm drain system(s). 10-foot wide
Public Service Easement shall be shown on the Final Map along Saratoga-Sunnyvale Road
property frontage.
25. Utilities. Prior to Final Map approval, the owner (applicant) shall furnish the Public Works
Department with satisfactory written commitments from all public and private utility
providers serving the subdivision guaranteeing the completion of all required utility
improvements to serve the subdivision.
26. Permits. The owner (applicant) shall secure all necessary permits from the City and any
other public agencies, including public and private utility providers, prior to commencement
of subdivision improvement construction. Copies of permits other than those issued by the
City shall be provided to the Public Works Department.
27. Park and Recreation Fee. The owner (applicant) shall pay the applicable Park and
Recreation Development fees prior to Final Map approval.
28. Best Management Practices. All building and construction related activities shall adhere to
New Development and Construction - Best Management Practices as adopted by the City for
the purpose of preventing storm water pollution.
29. Engineered Improvement Plan. The owner (applicant) shall submit engineered
improvement plans to the City Engineer in conformance with the approved Tentative Map
and in accordance with the design and improvement requirements of Chapter 14 of the
Municipal Code. The improvement plans shall be reviewed and approved by the City
Engineer and the appropriate officials from other public agencies having jurisdictional
83
Resolution No. 15-004
authority, including public and private utility providers, prior to approval of the Final Map.
30. Subdivision Improvement Plan Fee. The owner (applicant) shall pay a Subdivision
Improvement Plan Checking fee, as determined by the Public Works Director, at the time
Improvement Plans are submitted for review.
31. Improvement Agreement. The owner (applicant) shall enter into an Improvement
Agreement with the City in accordance with Section 14-60.010 of the Municipal Code prior
to Final Map approval.
32. Improvement Securities. The owner (applicant) shall furnish Improvement Securities in
accordance with Section 14-60.020 of the Municipal Code in the manner and amounts
determined by the Public Works Director prior to Final Map approval.
33. Indemnification. The owner (applicant) shall furnish a written indemnity agreement and
proof of insurance coverage, in accordance with Section 14-05.050 of the Municipal Code,
prior to Final Map approval.
34. Stormwater Treatment. The owner/applicant shall provide the Director of Public Works
with a plan describing how owner/applicant will implement all Best Management Practices
(BMPs) and other measures required to reduce the stormwater runoff impacts of the project,
as described in and required by the City's NPDES Municipal Regional Stormwater Permit,
Order R2-2009-0074 (as amended by Order R2-2011-0083) (“NPDES Permit”). The
measures included in this plan shall include, but are not limited to, construction site control
measures, plans for storm drain stenciling, and landscaping measures. This plan must be
approved by the Director of Public Works prior to final map approval. The owner/applicant
shall enter into a Stormwater Maintenance Agreement, which shall contain all of the
provisions required by the NPDES Permit and provide a funding mechanism(s), satisfactory
in form and content to the Director of Public Works, to ensure permanent funding for the
maintenance of the stormwater treatment systems or hydro modification controls developed
on the property as well as inspection and reporting. Upon owner/applicant's request, the City
will initiate proceedings to create an assessment district, which, if approved, shall be a
satisfactory funding mechanism for this maintenance, inspection, and reporting.
35. Landscape/Lighting District. The Property is included in existing Landscape and Lighting
Assessment District No. 1. Landscape and Irrigation plans for the property frontage along
Saratoga-Sunnyvale Road shall be submitted as part of the Improvement Plans.
36. NPDES Permit. Prior to beginning of construction, the applicant shall file a Notice of Intent
(NOI) with the Regional Water Quality Control Board, if required, to obtain coverage under
the State General Construction Activity NPDES Permit. Satisfactory evidence of the filing of
the NOI shall be furnished to the City. The applicant shall comply with all provisions and
conditions of the State Permit, including preparation and implementation of a Storm Water
Pollution Prevention Plan (SWPPP), if required. Copies of the SWPPP shall be submitted to
the City prior to beginning of construction and maintained on site at all times during
construction.
84
Attachment 2
1
Project Consistency with Applicable Saratoga-Sunnyvale Road Design Guidelines
12260 Saratoga-Sunnyvale Road (PDR14-0016 / Use Permit CUP14-0004 / SUB14-0002)
Design Guidelines Consistent with Project?
Architecture and Materials
1. Encourage smaller-scale building
floorplates with an appropriate scale and
architectural style, consistent with early
Californian architectural styles, (including,
but not limited to, Craftsman, Queen Anne,
Stick, and Mission) that conform to the look
of the general area. (Goal B,C)
Consistent. The proposed buildings would
be consistent with the look and feel of other
commercial and residential structures in the
area. The proposed architecture references a
traditional architectural style, with a mixture
of stucco and stone siding and terracotta tile
roofs.
2. Buildings should relate specifically to
Saratoga's residential areas and illustrate
residential massing with low-pitched gable
or hip roofs, dormer windows, etc. (Goal C)
Consistent. The roof portion visible from
the Saratoga-Sunnyvale Road would be of
mansard and similar to other commercial
structures. The townhomes would have a
similar appearance to residential roofs in the
neighborhood.
3. In order to reduce the perceived scale of
buildings, building masses shall be broken
into smaller components. Large “boxes”
with no articulation will not be allowed.
(Goal C)
Consistent. The facade of the building
visible from Saratoga-Sunnyvale Road
would be articulated and broken into
smaller components with the use of stone
veneer and stucco, and architectural
projections.
4. Building walls and rooflines should
include articulation, with a change in
surface materials, color or surface plane. All
primary building entrances must be
identified with architectural details such as
towers, projections, varied roofs, trellis
work, pergolas or covered entry ways. (Goal
B,C)
Consistent. A variety of materials would be
incorporated into the main façade of the
building, and the main entryways would be
emphasized using materials such as stone
veneer and aluminum-framed doors.
5. Buildings should be designed with
vertical breaks to create differentiation
along the front facade. This can be done
with indented balconies or/and articulation
of massing or/and changes in material,
texture, and color. (Goal C)
Consistent. The design of the project
features a covered entryway for the
commercial and residential buildings. The
residential buildings also incorporate second
floor balconies, architectural projections,
and a variety of exterior materials and
colors.
6. Corners of buildings should be
highlighted with special design features to
increase visual interest where appropriate.
Entrances or display windows to the retail
shops are encouraged at building corners
that face street corner locations. (Goal B)
Consistent. Display windows and stone
elements would be placed at the corners of
the commercial building, which would be
visible from Saratoga-Sunnyvale Road.
85
Attachment 2
2
Design Guidelines Consistent with Project?
7. Rooflines should be varied in style and
size to create interest. All buildings should
include roof features such as pitched roofs,
detailed parapets, or entry features. Rooftop
mechanical equipment shall be screened on
all sides. (Goal B,C)
Consistent. Covered entryways would
create a varied roofline on the buildings and
create interest. Rooftop equipment is not
proposed for the project.
8. Rooftop mechanical units, vents, and
flues shall be screened. Screening rooftop
mechanical equipment by means of pitched
roof forms or penthouses is encouraged.
(Goal B,C)
Consistent. See #7.
9. Service and loading areas should not be
located immediately adjacent to residential
uses or Saratoga Sunnyvale Road. (Goal
B,C)
Consistent. Loading would be located on
the northern portion of the site, adjacent to
commercial uses.
10. A specific color palette, list of materials,
and common architectural features will be
required for all development in the Saratoga
Gateway District. This is intended to
establish a common theme or style of
architectural design for all buildings within
the District. All buildings shall incorporate
360 degree (i.e., all building faces) use of
materials and color. (Goals B,C)
Consistent. Colors include tans, creams,
beiges, browns, grays, and reds. Specific
list of materials include cultured stone
veneer, terracotta roof tiles, wood siding
and exterior plaster. Common architectural
features second story balconies with
wrought iron railing, similar architectural
projections, and metal doors and frames.
11. Colors for all buildings should be earth
tones, neutrals and soft muted colors. The
predominant color should be in the range of
grays, beige through dark brown, terra cotta
and sandstone, dark greens, or muted red.
Bright intense colors are not allowed. Stark
white or black is discouraged for use other
than as trim. Un-muted primary colors are
not allowed. (Goals B,C)
Consistent. See #10.
12. Finish materials for walls should be
predominantly natural materials such as
brick, textured block, stone, slate, stucco,
wood, clap board siding or textured and
colored concrete that closely resembles such
materials. Accent materials may include
canvas for awnings, metal trim, ceramic
tiles, concrete castings, terra cotta, or
stucco. Window and door trim should be
bronzed or baked enamel colored finish that
is complimentary to the color of the wall.
Materials such as galvanized metal, glossy
Consistent. The facades of the project
would include natural-looking materials
such as stucco, and stone veneer. Window
and door trim would generally be of muted
aluminum construction with black color,
and would be complementary to other
design materials and consistent with other
commercial uses in the area.
86
Attachment 2
3
Design Guidelines Consistent with Project?
aluminum, smooth concrete, metal siding,
vinyl, and reflective glass are not allowed.
(Goals B,C)
13. Encourage canopies/awnings/arcades to
define entrances and provide shelter along
buildings. (Goal B)
Consistent. Covered entryways would be
provided for the commercial units.
14. Building entrances should be set back
from drive curblines to achieve public
safety and entry articulation. (Goal B)
Consistent. The building would be set back
from the curb line of the parking lot. A
landscape strip would buffer the curblines
with the parking area to achieve public
safety.
15. Building entrances should be
identifiable from parking areas. (Goal A, B)
Consistent. The building entryway would be
identifiable from front parking areas due to
the use of distinctive building materials and
prominent entryways.
16. Building materials should include
appropriate materials to achieve city council
goals. Such materials should establish a
single, recognizable style, consistent with
early California, for all adjacent commercial
areas. The rural residential character of the
City should be maintained through low
residential densities, extensive landscaping
along streets and the relatively low profile
and height of structures. In commercial
areas this can be achieved by the use of
architectural features, materials and color to
reduce bulk and mass. The use of traditional
residential architectural design themes that
can be transformed into effective
commercial functions can be an effective
method in which to achieve this goal. (Goal
B)
Consistent. The project would include a
landscape buffer along Saratoga-Sunnyvale
Road and traditional architectural themes,
including mansard roof forms and the use of
natural-looking materials such as stone
veneer and tan colored stucco. The use of
traditional residential architectural design
themes incorporated into the residential
townhomes (such as earth tone exterior
colors and natural materials) have been
incorporated into the commercial building,
which assists in keeping the rural residential
character of the City.
17. A predominance of masonry, wood and
brick shall be used on ground levels of all
buildings. (Goal B)
Consistent. The building would utilize
stucco and stone veneer on both the
commercial and residential structures.
18. Reflective materials such as bright
aluminum and glass are not allowed as the
primary building material on exteriors.
(Goal B)
Consistent. The colors and materials of the
project include earth tone browns, grays,
and reds with siding and stone.
19. Pedestrian amenities, such as benches,
trash receptacles, outdoor dining and vendor
carts on private property, are encouraged to
Not Yet Determined. The design of such
pedestrian amenities has not yet been
finalized by the project sponsors.
87
Attachment 2
4
Design Guidelines Consistent with Project?
be consistent with the theme established by
Saratoga-Sunnyvale Road Gateway. (Goal
B)
Landscaping and Buffering
1. Landscape islands should be provided in
parking lots to interrupt consecutive runs of
parking spaces. Landscape islands shall
incorporate a mix of shade tree and shrub
plant material to visually buffer internal site
views from both ground and to provide
shade. (Goal B,C)
Consistent. Landscape buffers would be
provided in the surface parking lot.
2 Parking areas should incorporate low
landscaping buffers to screen parked cars
from adjacent streets. All head in parking
adjacent to public right of way or residential
areas shall be screened by one of the
following: masonry wall, earthen berm,
and/or dense shrub planting. (Goal B,C)
Consistent. Landscape buffers would screen
the surface parking lots proposed adjacent
to Saratoga-Sunnyvale Road. Landscape
buffers and shrubs would be used to screen
the surface parking area to the east, and
existing wall would be left in-place.
3. Landscaped parking islands and medians
should constitute a substantial portion of the
overall parking area to achieve an attractive
commercial environment consistent with the
Saratoga environment. (Goal B,C)
Consistent. Landscaped areas would be
included in the parking lot.
4 The use of landscaping should be
encouraged to distinguish access points,
break up parking and define pedestrian
access and spaces. (Goal B,C)
Consistent. Landscaping would be utilized
throughout the site to identify access points
and walkways.
5 Landscape layout and design should orient
the pedestrian environment. (Goal B)
Consistent. Landscaping would be used to
connect the pedestrian realm adjacent to
Saratoga-Sunnyvale Road to the pedestrian
walkways on the site.
6. Street tree plantings shall be required
where none exist along Saratoga-Sunnyvale
Road to promote a consistent tree canopy,
reduce perceived building heights and
provide shade. Street trees shall be pruned
and otherwise maintained to provide
visibility of businesses and to encourage
proper growth and height. (Goal B,C)
Consistent. Trees are being proposed along
the front setback of the project and adjacent
to Saratoga-Sunnyvale Road.
7 Private drives serving the internal
circulation needs of proposed development
shall require street tree plantings. (Goal
B,C)
Consistent. The landscape plan identifies an
existing tree adjacent to the private drive.
8 Shrubs, groundcovers and perennial Consistent. Groundcovers and other low-
88
Attachment 2
5
Design Guidelines Consistent with Project?
plantings are encouraged between detached
pedestrian walks and buildings. (Goal B,C)
growing plant species would be planted
adjacent to the proposed buildings.
9 Trellises with flowering vines and
hanging flower baskets are encouraged at
building entries to make the entry more
easily identifiable, provide pedestrian scale
and add visual interest. (Goal B,C)
Not Yet Determined. Hanging flower
baskets would be decision of the tenant as it
is a temporary measure.
10. Buffering between commercial or mixed
use projects and adjacent residential uses
shall incorporate the following: (Goal B,C)
• Solid (decorative) masonry wall.
• Exclusive landscape buffer area reserved
for buffering purposes - no private outdoor
use or other programmed activities are
allowed within the buffer area.
• Trees shall be 24” boxed size minimum.
• Privacy issues shall be addressed through
the citing of balconies and windows above
ground floor level adjacent to residential
properties to protect the privacy of
residential neighbors.
• Rear or side parking lots adjacent to
residential uses shall be designed to
address after hour security.
Consistent. A concrete wall would be
constructed between the project and the
adjacent residential uses. Trees proposed
would meet the 24-inch box minimum
requirement. Privacy and security issues
would be addressed through the setback of
the buildings from the eastern property line
of the sites (and adjacent residential uses).
The project does not have a rear parking lot,
but rather a small parking area for a single
vehicle.
11. Buffering between commercial or mixed
use development and other similar uses
shall consist of a landscape area planted
with trees, shrubs and groundcovers. (Goal
B,C)
Consistent. A landscaped buffer would be
planted along the eastern boundary of the
site, adjacent to residential uses.
12. The following list of trees shall be
considered for incorporation into the design
of commercial parking lots. (Goal B,C)
Consistent. Pistacia chinensis (Chinese
pistache) are listed in the “considered tree
species” within the Design Guidelines and
are proposed to be remain within the front
parking lot area. A Posocarpus gracilior
(Yew Pine) is proposed to the rear of the
site, in order to accommodate privacy
concerns of the residential uses.
Fencing and Screening Walls
3. Fencing is discouraged between
properties of similar use. (Goal A,B,C)
Consistent. Fences would not be proposed
between similar uses, yet a fencing of the
rear yard and patio would be placed
between the residential uses and
commercial uses located to the south.
5. Trash, service and loading areas should Consistent. Trash and loading areas would
89
Attachment 2
6
Design Guidelines Consistent with Project?
not be located adjacent to street frontages or
adjacent to existing residential uses and will
be screened from view from public streets.
(Goal B,C)
occur adjacent to the northern area of the
site, separated from residential uses to the
west of the site by a parking area and
driveway. The garbage and recycle bins will
be kept in the enclosed garages as depicted
on the floor plans.
Note: Policies related to Commercial Retail Signage and Lighting and Furnishings are not included in this Attachment because
the project sponsors have not yet submitted detailed signage, lighting, and furnishing plans.
90
RW ENGINEERING, INC.
Civil Engineers · Land Surveyors
505 Altamont Drive, Milpitas, CA 95035
Tel: (408) 262-1899 Fax: (408) 824-5556
Email: rwengineering@gmail.com
January 23, 2015
City of Saratoga – Planning Division
13777 Fruitvale Ave., Saratoga, CA 95070
Re: Story Pole Certification
Project Site: 12260 Saratoga-Sunnyvale Road, Saratoga, California
Project Number: PDR14-0016
Dear Sir:
We have surveyed the story poles located at 12260 Saratoga-Sunnyvale Road. Based on our
survey, I certify that story poles located on the above-referenced site are in substantial
conformance with the design, height and location shown on the plans submitted for Planning
Application PDR14-0016.
For additional information, please contact me at (408) 262-1899.
Feel free to contact me if you have any questions.
Sincerely Yours,
Robert Wang, PE, PLS
91
92
93
94
95
96
97
98
99
100
101
CITY OF SARATOGA
Community Development Department
13777 Fruitvale Avenue
Saratoga, CA 95070
(408) 868-1222
NOTICE OF PUBLIC HEARING
The City of Saratoga’s Planning Commission announces the following public hearing on:
Wednesday, the 11th day of February, 2015, at 7:00 p.m.
The public hearing will be held in the City Hall Theater located at 13777 Fruitvale Avenue. The
public hearing agenda item is stated below. Details of this item are available at the Saratoga
Community Development Department, Monday through Friday 7:30 a.m. – 5:00 p.m. Please
consult the City website at www.saratoga.ca.us regarding Friday office closures.
APPLICATION/ADDRESS: PDR14-0016, CUP14-0004, & SUB14-0002 / 12260
Saratoga-Sunnyvale Road
APPLICANT/OWNER: Anwar Awad / West Valley Muslim Association
APN: 386-30-035
DESCRIPTION: The applicant is requesting Design Review, Conditional Use Permit, and
Subdivision approval for the construction of one 2,297 square feet commercial / retail building
that is 20 feet in height and twelve residential townhomes, each approximately 2,400 square feet
in size and 27 feet in height, totaling approximately 34,000 square feet. The project is in
conformance with City standards for height, setbacks, floor area, and site coverage. The site is
1.20 acres in size and is zoned CV.
All interested persons may appear and be heard at the above time and place. If you challenge a
decision of the Planning Commission pursuant to a Public Hearing in court, you may be limited to
raising only those issues you or someone else raised at the Public Hearing. In order for information
to be included in the Planning Commission’s information packets, written communications should
be filed on or before Tuesday, February 3, 2015
This notice has been sent to all owners of property within 500 feet of the project that is the subject
of this notice. The City uses the official roll produced by the County Assessor’s office annually, in
preparing its notice mailing lists. In some cases, out-of-date information or difficulties with the U.S.
Postal Service may result in notices not being delivered to all residents potentially affected by a
project. If you believe that your neighbors would be interested in the project described in this
notice, we encourage you to provide them with a copy of this notice. This will ensure that everyone
in your Community has as much information as possible concerning this project.
Christopher Riordan
Senior Planner
(408) 868-1235
102
103
104
105
106
107
108
109
110
LEGEND
ABBREVIATION
12260 SARATOGA SUNNYVALE ROAD
SARATOGA, CALIFORNIA
TENTATIVE MAP
FOR 13-LOT RESIDENTIAL & COMMERCIAL SUBDIVISION
IN THE CITY OF SARATOGA, SANTA CLARA COUNTY
CALIFORNIA
N
GENERAL NOTES:SITE PLANAS NOTED
RW
6/21/14
RW
TM-1
DATE:
SHEET NO.
SCALE:
DRAWN BY:
DESIGNED BY:RWRW ENGINEERING, INC.DATEBYREVISIONNO.1 OF 3 SHEETS
DESCRIPTION
SHEET INDEX
NO.
TYPICAL PRIVATE STREET SECTION
111
EARTHWORK TABLE
CUT (CY)FILL (CY)IMPORT
(CY)LOCATION
AS NOTED
RW
6/21/14
RW
TM-2
DATE:
SHEET NO.
SCALE:
DRAWN BY:
DESIGNED BY:RWRW ENGINEERING, INC.DATEBYREVISIONNO.2 OF 3 SHEETS
BENCHMARK: PRELIMINARYGRADING &DRAINAGE112
•
•
•
•
•
•STORMWATERCONTROL PLANTYPICAL BIO-RETENTION BASIN
#
TABLE 2: IMPERVIOUS AREA AND TREATMENT DEVICE
AS NOTED
RW
6/21/14
RW
TM-3
DATE:
SHEET NO.
SCALE:
DRAWN BY:
DESIGNED BY:RWRW ENGINEERING, INC.DATEBYREVISIONNO.3 OF 3 SHEETS
#
#
#
#
#
#
#
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140