Loading...
HomeMy WebLinkAbout02-12-19 Planning Commision Study Session Agenda Packet Saratoga Planning Commission Meeting Agenda – Page 1 of 1 SARATOGA PLANNING COMMISSION SPECIAL MEETING February 12, 2019 6:00 P.M. - STUDY SESSION Linda Callon Conference Room | 13777 Fruitvale Ave., Saratoga CA 95070 ROLL CALL ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS Any member of the Public will be allowed to address the Planning Commission for up to three (3) minutes on matters not on this agenda. The law generally prohibits the Planning Commission from discussing or taking action on such items. However, the Planning Commission may instruct staff accordingly regarding Oral Communications under Planning Commission direction to Staff. AGENDA ITEMS 1. Housing Legislation Presentation 2. Review of Subterranean Structures Definition ADJOURNMENT Certificate of Posting of the Agenda, Distribution of Agenda Packet, & Compliance with Americans with Disabilities Act I, Janet Costa, Executive Assistant for the City of Saratoga, declare that the foregoing agenda for the meeting of the Planning Commission was posted and available for review on February 7, 2019 at the City of Saratoga, 13777 Fruitvale Avenue, Saratoga, CA 95070 and on the City's website at www.saratoga.ca.us. Signed this 7th day of February 2019 at Saratoga, California. Janet Costa, Executive Assistant In accordance with the Ralph M. Brown Act, copies of the staff reports and other materials provided to the Planning Commission by City staff in connection with this agenda are available at City Hall at 13777 Fruitvale Avenue, Saratoga, CA 95070. Any materials distributed by staff after the posting of the agenda are made available for public review at City Hall at the time they are distributed to the City Council. In Compliance with the Americans with Disabilities Act, if you need assistance to participate in this meeting, please contact the City Clerk at 408/868-1269. Notification 24 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility to this meeting. [28 CFR 5.102- 35.104 ADA title II] You can also sign up to receive email notifications when Commission agendas and minutes have been added to the City website at: www.saratoga.ca.us/subscribeNOTE: To view previous Planning Commission meetings anytime, go the City Video Archives at www.saratoga.ca.us CITY OF SARATOGA Memorandum To: Planning Commission From: Debbie Pedro, Community Development Director Date: February 12, 2019 Subject: Housing Legislation An overview of past and upcoming efforts related to housing, including recently adopted housing legislation, will be presented at the Study Session meeting on February 12, 2019. This is the same presentation that the City Council received at their retreat on February 1, 2019. Topics of discussion included: 1. Review of Saratoga’s Housing Element implementation. 2. Review and update on the 2017 housing bills. 3. Anticipated new housing legislation that would affect Saratoga. Study Session: Subterranean Structure Definition February 12, 2019 Page 1 of 6 CITY OF SARATOGA Memorandum To: Planning Commission From: Debbie Pedro, Community Development Director Date: February 12, 2019 Subject: Study Session for Subterranean Structure Definition BACKGROUND: In recent years, the City has received subterranean structure design proposals which may have represented a departure from the designs which were envisioned during the drafting of the regulations in 2013. Staff has researched the City’s permit records and will provide the list of subterranean structures approved in the past several years at the study session. According to Commission Walia, the original intent of the subterranean structure regulations was to provide for stand-alone accessory structures which do not have an exposed surface except for the minimum required ingress/egress, lighting, and ventilation. However, the current regulations, as written, do not specify that a subterranean structure must be detached, nor does it limit the exposed surface of the structure to the “minimum” required ingress/egress, etc. Therefore, the City Code may have to be amended to better articulate and clarify the original intent of the regulations. On September 19, 2018, the City Council reviewed the proposed cleanup amendments to the City Code for the 2018 Annual Code Update and in addition to the items proposed, directed staff to clarify the definition of subterranean structure by adding appropriate references to the regulations applicable to basements and adding a requirement that subterranean structures not be visible from the public right of way. (Attachment 1) On November 14, 2018, the Planning Commission reviewed the proposed Annual Zoning Code Amendments and unanimously voted to remove the subterranean structure definition from the Code Update for future discussion. (Attachment 2) On December 11, 2018, the Planning Commission held a Work Plan Study Session and included review of the subterranean structure definition in the Commission’s 2019 Work Plan. (Attachment 3) At the January 9, 2019 meeting, the Planning Commission expressed concerns regarding confusion over subterranean structure regulations. To address pending and future Study Session: Subterranean Structure Definition February 12, 2019 Page 2 of 6 development projects that may include subterranean structures, the Commission requested that staff bring forth the item for review and discussion as soon as possible. DISCUSSION: Neither basements nor subterranean structures (located outside a building’s footprint) are considered as part of the floor area. The primary area of complexity arises in determining when a portion of a structure should be considered a basement (not included in floor area) or a story (included in floor area). In general, if the finished floor above a below-grade space in a structure is less than 42 inches above grade, the space is considered a basement (and therefore not included in the floor area). If the finished floor above the below-grade space is more than 42 inches above grade then the space is considered a story and not a basement and is included in the floor area. Slightly different rules apply to hillside lots. The calculations depend on a number of factors, however, as set forth in the definition in the Code. The City’s Basement Ordinance was last updated in 2002 (Ord.# 209). In the 2013 Annual Code Update, the City Council added the definition of Subterranean Structure because the City Code did not include a definition or development standards for subterranean structures when they are located outside the footprint of an existing structure. The definitions of floor area, basement, and subterranean structure are presented below. 15-06.280 - Floor area. "Floor area" means the total enclosed, habitable or accessible floor space of all floors of a building where the interior height of the area is equal to or greater than five feet. The term "enclosed," as used in this Section, means a structure or area with a roof and with three or more walls, or an equivalent percentage of enclosure. The term "roof," as used in this Section, means a covering of any solid material over at least seventy-five percent of the area. Floor area is measured to the outside surfaces of exterior walls. In the case of a sloped ceiling or ground surface, the floor area shall be measured to the point at which the interior height is less than five feet. Pursuant to the foregoing, floor area may include halls, stairways, elevator shafts, ducts, service and mechanical equipment rooms, underfloor areas, porches, verandas and similar building elements, garages, attics, crawl spaces and accessory structures. Floor area does not include interior courts, which are areas surrounded on all sides by habitable space but which do not have a roof, as defined in this Section. (Ord. 71-177 § 2, 1998; Ord. 223 § 2 (part), 2003; Ord. 245 § 2 (Att. A) (part), 2006) Study Session: Subterranean Structure Definition February 12, 2019 Page 3 of 6 15-06.090 - Basement. "Basement" means a space in a structure that is partly or wholly below grade and where the vertical distance from grade to a finished floor directly above such space is less than or equal to forty-two inches. (See Figure 1a) If the finished floor directly above the space is more than forty-two inches above grade at any point along the perimeter, such space shall be considered a story, and the entire space shall be included in the calculation of floor area. This requirement applies to all lots, with the exception of hillside lots. On hillside lots, as defined in Section 15-06.420(e) 1, only the portion of space where the vertical distance of the finished floor directly above such space is more than forty- two inches above grade shall be counted as floor area and considered a story. The number of stories measured vertically at any given point shall not exceed the maximum number of stories allowed in each zoning district. (See Figure 1b) However, if the vertical distance of the finished floor above the space is not more than forty-two inches above grade for at least eighty percent of area of such space, then the entire space is a basement that shall not be included in the calculation of gross floor area and shall not be considered a story. (See Figure 1c.) 1 15-06.420 – Lot. (e) Hillside lot means a lot having an average slope of ten percent or greater. Study Session: Subterranean Structure Definition February 12, 2019 Page 4 of 6 As used herein, the term "grade" shall mean either the natural grade or finished grade immediately adjacent to the exterior walls of the structure, whichever is lower. The Community Development Director shall make the determination for sites where it is unclear as to which is the natural and which is the finished grade. Basements are subject to the requirements of Section 15-80.035. (Amended by Ord. 209 § 2 (part), 2002; Ord. 223 § 2 (part) 2003; Ord. 245 § 2 (Att. A) (part), 2006) (Ord. No. 284, § 1(Att. A), 5-18-2011) 15-06.685 - Subterranean Structure. "Subterranean Structure" includes a cellar, bunker, or other structure that (a) is not located beneath the building footprint of a structure; (b) does not encroach into setback areas; and (c) is located wholly underground except for required ingress/egress, lighting and ventilation. The floor area of subterranean structures is not counted against a property's maximum floor area and only fifty percent of the floor area is counted against a property's maximum site coverage. (Ord. No. 307, § 1.C.9, 10-16-2013) 15-06.670 - Structure. "Structure" means that which is built or constructed which requires a location on the ground, an edifice or building of any kind, or any piece of work artificially built up or composed of parts joined together in some definite manner. "Structure" includes retaining walls, decks, patios, swimming pools, and recreational courts but does not include a fence not exceeding six feet in height. (a) Main structure means a structure housing the principal use of a site or functioning as the principal use. (b) Accessory structure is as defined in this Chapter. (Amended by Ord. 223 § 2 (part), 2003; Ord. 245 § 2 (Att. A) (part), 2006) 15-06.022 - Accessory structure. "Accessory structure" means a structure which is: (a) detached from any other structure such that the distance between any part of the two structures is thirty-six inches or more; and (b) incidental and subordinate to, and customarily associated with, the main structure or principal use on the lot. Notwithstanding the foregoing, an accessory dwelling unit is not an accessory structure as that term is used in this Code. No accessory structure is permitted in any zone district in the absence of an existing or concurrently established main structure or principal use on the lot. (Ord. 223 § 2 (part), 2003; Amended by Ord. 245 § 2 (Att. A) (part), 2006) (Ord. No. 272, § 2(exh. A), 9-16-2009; Ord. No. 348, § 1(Att. A, § 6), 1-18-2017) Study Session: Subterranean Structure Definition February 12, 2019 Page 5 of 6 In addition to the definitions above, the following section of the City Code has additional requirements for basements and lightwells. 15-80.035 - Requirements for basements and lightwells. The following requirements shall apply to basements in any A, R-1, HR, R-OS or R- M district, with the exception of requirements in subsections (d) and (e) of this Section, which shall apply to all districts: (a) A basement shall be located beneath the building footprint of an enclosed structure and shall not be located, with the exception of lightwells, within any required setback area. The building footprint is the floor area from the exterior surface of the exterior walls of the ground floor of all main or accessory structures on a lot. (b) A lightwell may not extend into a required side setback area more than three feet and into a required rear setback area more than four feet. (c) A basement shall be a one level structure with a maximum floor to ceiling height of twelve feet. Floor, in this case, means finished floor, and ceiling means the bottom level of the ceiling framing members. (d) All proposed basements and additions to basements identified on the City's Ground Movement Potential Map as being located in an area with significant potential for ground movement shall obtain geotechnical clearance. The applicant shall submit to the Planning Department a geotechnical report prepared by a registered geotechnical engineer or registered civil engineer with competence in geotechnical investigation and design. This report shall include an analysis of seasonal groundwater conditions potentially impacting the project and design recommendations for any appropriate measures to address subsurface water. The geotechnical consultant shall address the potential need for substantial sump pump operation requirements where groundwater is anticipated to rise above the basement floor. Incorporation of subdrain systems beneath basement floors and appropriate waterproofing measures shall be considered during preparation of geotechnical design criteria for basements. (e) Applicant shall submit to the Planning Department a grading and drainage plan stamped and signed by a registered civil engineer. Water collected from a basement shall either be transported to a nearby City storm drain inlet or to another drainage facility. The method of drainage shall be reviewed and approved by the Community Development Director. Disposition and treatment of on-site storm water shall be consistent with the requirements of the Santa Clara Valley Urban Runoff Pollution Prevention Program (NPDES requirements). Study Session: Subterranean Structure Definition February 12, 2019 Page 6 of 6 The size of a proposed basement may be limited based on drainage issues or issues raised in the geologic and geotechnical reports. The cut and fill volumes associated with a proposed basement shall not be included in the total required cut and fill grading calculations required to be documented for the property. (Amended by Ord. No. 272, § 2(exh. A), 9-16-2009; Ord. No. 307, § 1.C.25, 10-16- 2013; Ord. No. 328, § 1(Att. A, § 21), 7-1-2015) The goal of this evening’s study session is to familiarize the Commission with the City’s current regulations for basements and subterranean structures, discuss the Commission’s identified issues and concerns, and provide staff with direction on any modifications needed to clarify the intent of the ordinance. For comparison, basement and subterranean structure regulations in other jurisdictions are included in Attachment 4. ATTACHMENTS: 1. City Council Meeting Minutes dated September 19, 2018 2. Planning Commission Meeting Minutes dated November 4, 2018 3. Planning Commission 2019 Work Plan Staff Report dated December 11, 2018 4. Basement and Subterranean Structure Regulations in Other Jurisdictions –5 8 . 3.3. RIGHT OF WAY . , Attachment 1 –2 3 . 1.2 0001 . City Code. The changes include clarifying the definition of “Subterranean Structures”, on for “Wineries” to Article 15 1235 . . . 1.3 0002 – 1225 or . APPROVE WITH . Attachment 2 REPORT TO THE PLANNING COMMISSION Meeting Date: December 11, 2018 Subject: Planning Commission 2019 Work Plan Address/APN: Citywide Owner / Applicant: City of Saratoga From: Debbie Pedro, Community Development Director STAFF RECOMMENDATION Staff recommends that the Commission discuss its priority work plan items for the coming year, to be forwarded to City Council early in 2019 for Council input and direction. No formal action is requested or may be made at a study session, but straw polls may be appropriate to indicate priorities. BACKGROUND The Planning Commission discusses its potential Work Plan items for the coming year in November or December of each calendar year. The Council then reviews the items suggested in a joint session with the Commission or in another format, and provides input and direction regarding where the Commission should focus its efforts. Attachment 1 is a copy of the transmittal of the Commission’s 2018 Work Plan to Council on March 21, 2018. DISCUSSION The Commission’s 2018 Work Plan focused on the following core priorities: 1)General Plan Element Update (Circulation, Open Space/Conservation, and/or Land Use). 2)Implementation of the Village Policy Update, i.e. Village Parking Standards, Village Design Guidelines Staff expects that the items above will continue to be the major focus for the Commission in 2019. The following is a summary of the Work Plan items proposed for 2019. General Plan Update. Continue work on the General Plan Update. In April 2018, the City began the 18 month process to refresh and make minor policy updates to three elements of the City’s General Plan (Land Use, Circulation, and Open Space & Conservation). So far, the Commission has held five study sessions to solicit input from the public. The consultant and staff are working on incorporating Commission comments in the updated documents. The tentative timeline for Commission review of the draft documents is Spring 2019. Attachment 3 Report to the Planning Commission Work Plan Study Session December 11, 2018 Page | 2 Village Policy Update. Continue work on the implementation of the Village Policy Update. In 2017, the City Council affirmed the Planning Commission’s recommendations to update the Village Parking Standards and Village Design Guidelines. An ordinance amending the Village Parking Standards was recently completed. Staff, with the assistance of a consultant, is updating the graphics in the Design Guidelines to create a document that is organized and illustrated for optimal use by property and business owners within the Village. The updated Village Design Guidelines will be reviewed by the Planning Commission and forwarded to the City Council for final adoption. Subterranean Structure Definition. Per Council’s direction in September 2018, clarify the definition of Subterranean Structures by adding appropriate references to the regulations applicable to basements and add a requirement that subterranean structures not be visible from the public right of way. (Section 15-06.685). Tree Regulations Ordinance. The Santa Clara County Fire Department has identified blue gum eucalyptus (Eucalyptus globulus) as a “problem invasive” tree and suggests that its removal may reduce fire risks. The City arborist is recommending modification to the City’s tree regulations (Article 15-50) to allow the removal of blue gum eucalyptus with a tree removal permit. Other Items If the Commission feels that other items deserve its priority attention in 2019, they should bring those items up for discussion at the Study Session. ATTACHMENT 1.City Council Staff Report Regarding the Planning Commission 2018 Work Plan dated March 21, 2018 Hillsborough Municipal Code 17.32.020 - Total covered floor area. A.For purposes of Sections 17.32.030 and 17.32.040, the phrase "total covered floor area" shall mean the total area of all buildings on the lot (except for excluded accessory structures listed in this section) measured to the exterior wall lines thereof (i.e., the outside edge of exterior walls). This shall include all roofed areas with a level floor-to-ceiling height of at least seven feet, including basements as set forth in subsection C of this section, closets, stairwells, bay windows, turrets, and other projections bounded by two or more exterior walls, plus the additional amount of square footage, if any, specified by subsections B and D of this section. For purposes of this chapter, floor area includes finished or unfinished floor area. The foregoing notwithstanding, the following accessory structures shall be excluded from (i.e., not counted in) the floor area calculation: trellises, open gazebos, open pergolas, open decks, carports open on at least two sides, and other structures of a similar type as determined by the town's planning office. B.For rooms or areas with low sloping ceilings, such as attics, all floor areas with a level floor-to-ceiling height of at least five feet shall be counted as floor area. C.For basement areas with exterior walls less than two feet above the surrounding natural grade, thirty-three percent of all floor areas with a level floor-to-ceiling height of at least six feet shall be counted as floor area. For basement areas with exterior walls two feet or more above the surrounding natural grade, one hundred percent of all floor areas with a level floor-to-ceiling height of at least six feet shall be counted as floor area. The height of exterior basement walls shall be measured from the surrounding natural grade to the plate height of the ground-level floor above. D.For spaces with high ceilings, one hundred and fifty percent of all floor area (after the first three hundred square feet, which shall be counted at one hundred percent) with a floor-to- ceiling height greater than twelve feet shall be counted as floor area. (Ord. 657 § 4, 2005; Ord. 639 § 20 (part), 2003) Attachment 4 TOWN OF LOS ALTOS HILLS 26379 Fremont Road Los Altos Hills, CA 94022 Phone: (650) 941-7222 www.losaltoshills.ca.gov Basement Ordinance Effective Date: 11/20/2011 Sec. 10-1.202 Basement "Basement" shall mean a floor level, or portions thereof, which has: (1) all portions directly below a building; and (2) the finished floor elevation of the building level above shall not be greater than twenty- eight (28”) inches above the adjoining natural or finished grade, whichever is lower; and (3) have at least 75% of its perimeter length wholly underground; and Daylighted basements shall comply with all height and setback requirements of this ordinance. Basements including cellars and bunkers, which are not located within the footprint of the building above, may be permitted by the Planning Commission when it finds that such structures do not encroach in setbacks, are a minimum of 18 inches below natural grade, are wholly underground except for required exiting, lighting and ventilation and are counted as development area except when placed under a surface already counted as development area. Bunker area that exceeds 1,500 square feet shall be counted as Floor Area. Daylight Basement Structure Height Setback: For basement floor levels, the floor area portion and the first 20 feet of a daylighted basement shall be limited to a structure height of 27 feet as measured from the basement pad elevation to the highest portion of the roof structure above. (See Example #4) Note: Daylighted basements shall comply with the Town’s grading policy. The Grading Policy is used by staff in evaluating and making recommendations to the Planning Commission and/or City Council regarding site development applications, and as guidance for applicants. Individual sites may dictate a need to deviate from the criteria, to the extent permitted by the Planning Commission and/or City Council. Policy: Basement Ordinance Page 2 BASEMENT EXAMPLES 1st Story Basement Natural Grade Finish Grade 1st Story Natural Grade Finish Grade EL 239.52’ SECTION Floor Area PLAN Floor Area Basement Basement EL 239.52’ At least 75% of basement perimeter wholly underground Standard Basement 1 2 Daylight Basement 3 Topography line at 28” below the FF elevation Max 4 foot tall retaining walls Basement Retaining Wall and Floor Frame Detail Topography line at 28” below the FF elevation Basement 20’ 20’ Floor Area 4 Daylight Basement Structure Height Setback 28” below the 1st FF elevation Floor Area Basement ORDINANCE ORDINANCE OF THE TOWN OF LOS GATOS AMENDING CHAPTER 29 (ZONING REGULATIONS) OF THE TOWN CODE REGARDING CELLARS WHEREAS, the Town Council wishes to simplify and provide clarity with regard to below grade square footage; and WHEREAS, the proposed code amendments are consistent with the General Plan and its Elements. THE TOWN COUNCIL OF THE TOWN OF LOS GATOS DOES ORDAIN AS FOLLOWS: SECTION I Town Code Chapter 29 is hereby amended to read as follows: CURRENT DEFINITIONS: Sec. 29.10.020 -Definitions. SsseFReRt means an enclosed area that extends more than fol:.lr (4) feet above the existing or finished grade in any loeation. Basements, as defined here, shall be incll:.lded in the floor area ratio eale1:Jlation. For pl:.lrposes of this definition, whiehever grade (existing or proposed) resl:.llts in the lowest bl:Jilding profile of a bl:Jilding shall be 1:Jsed. CeJl.sr means an enclosed area that does not extend more than fol:Jr (4) feet abo•.-e the existing or finished grade in any loeation. Cellars, as defined here, shall not be incll:Jded in the floor area ratio ealel:Jlation for residential developments. That area of a eellar •Nhere the bl:Jilding height exeeeds fol:Jr (4) feet above existing or finished grade shall not be incll:Jded in this definition and shall be inell:Jded in the floor area ratio ealel:Jlation. For pl:.lrposes of this definition whiehever grade (existing or proposed) resl:Jlts in the lowest bl:Jilding profile of a bl:Jilding shall be 1:Jsed. AMENDED DEFINITIONS: Sec. 29.10.020 -Definitions. Floor Area, gross means the entire enclosed area of all floors that are more than four feet above the proposed grade at any liJOint on the elevation, incll:Jding basements and eellars, measured from CITY OF MONTE SERENO 18041 SARATOGA-LOS GATOS ROAD, MONTE SERENO, CA 95030 (408) 354-7635 • FAX (408) 395-7653 • WWW.CITYOFMONTESERENO.ORG P:\Front Counter Handouts\Building Heights & Basements.docx 7/2018 BUILDING HEIGHTS & BASEMENTS Building Height means the vertical distance measured from the natural grade or finished grade, whichever is lower, to the point of the structure above, except where a crawl space, Basement or Daylight Basement exist. In areas where a crawl space, Basement or Daylight Basement exist, building height shall be calculated from the average natural grade to the point of the structure above. Additional Information: When the structure is on a slab foundation, the building height is measured from the natural grade or finished grade, whichever is lower. Otherwise it is measured from the average natural grade. When using the average natural grade to show overall height a roof plan with elevation contours overlaid on the plan can be used to indicate the proposed height of the structure. Basement means any habitable space contained within the structure where the floor above does not exceed 48” above the finished grade at any point along the perimeter of the building footprint. A basement cannot extend beyond the footprint of the floor above. Daylight Basement means any habitable space contained within the structure where a portion of the floor above does not exceed 48” above the finished grade along the perimeter of the building footprint and a portion of the floor above exceeds 48” above the finished grade along the perimeter of the building footprint. Floor Area means the entire area of all floors, measured from the outer face of the exterior walls. Basements as defined in 10.01.020D for main dwellings shall not be counted in the floor area. Daylight Basement as defined in 10.01.020D for main dwellings shall not be counted for the portion of the floor area where the floor above does not exceed 48” above the finished grade along the perimeter of the building. Daylight Basements areas where the floor above exceeds 48” above the finished grade along the perimeter of the building shall be counted in the floor area. Additional Information: When calculating floor area for structures that have a Daylight Basement indicate on the floor plan which area is considered a basement (does not count towards the maximum floor area) and which area is consider a daylight basement (counts towards the maximum floor area. Portola Valley Municipal Code 18.04.065 - Basement. "Basement" is a floor level directly under a building which meets the following criteria: A. The ceiling height is not more than twelve feet. B. Provisions for light, ventilation and access do not exceed the minimum requirements of the building code, notwithstanding that additional provisions for light, ventilation and access may be permitted by the architectural and site control commission when it finds such additional provisions will not be visible from adjoining or nearby properties as such properties currently exist or as the architectural and site control commission believes may be used or developed in the future. Garages are not permitted under this provision. By virtue of the foregoing definition, a basement is permitted to meet the minimum requirements of the building code, including, but not limited to, light, ventilation and access, without approval of the architectural and site control commission. C. The underside of the floor joists of the floor above are not more than eighteen inches above the adjoining natural or finished grade at any point, whichever is lower. D. Where a room(s) partially meets the provisions of subsection C. of this section, that is, a portion is not more than eighteen inches above adjoining natural or finished grade, whichever is lower, and a portion is more than eighteen inches above such grade, a portion of such room(s) shall be considered as basement and a portion shall be considered as floor area. The rule for such determination shall be as follows: 1. The outside perimeter of the room(s) shall be measured and designated "A." 2. The outside perimeter of the room(s) where the underside of the floor joists of the floor above are not more than eighteen inches above adjoining natural or finished grade, whichever is lower, shall be measured and designated "B." 3. The amount of floor area of the subject room(s) that will be counted as basement is then equal to the entire floor area of the room(s) multiplied by the fraction of B/A. The balance of the floor area shall be counted as floor area. E. The basement floor area shall not exceed the floor area of the first floor of the building above. (Ord. 2017-419 § 2, 2017; Ord. 1999-323 § 1, 1999: Ord. 1995-285 § 1 Exh. A (part), 1996: Ord. 1988-242 3 (Exh. B) (part), 1988) A = The gross area in acres of the parcel or lot. Measurements along contours shall be made at contour intervals not to exceed ten feet, and a horizontal map scale of one inch equals 200 feet or larger. BACKFILL. The replacement of removed earth materials from Excavations with excavated or approved new material, such as sand, gravel, rock, or earth BASEMENT. An improved or unimproved space which is fully or partially below the Existing Grade or Finished Grade, whichever is lower, so that the vertical distance from the adjoining ground to the top of the interior structural ceiling is no more than two feet above grade. This shall include below grade patios, vehicular Tunnels including the driveway approach, and egress/light wells, but does not include Crawl Space. BASEMENT, DAYLIGHTED. An improved or unimproved space which is partially below the Existing Grade or Finished Grade, whichever is lower, so that the vertical distance from the adjoining ground to the top of the interior structural ceiling is more than two feet above grade. Daylighted Basements do not include Crawl Space. Daylighted Basements count towards Total Floor Area pursuant to Section 153.055. BEDROCK. The undisturbed rock exposed or beneath the soil. BENCH. A relatively level step excavated into earth materials. BUILDING PERMIT. A permit issued by the Town for the construction, erection, or alteration of a structure or building. CERTIFICATION. A statement that required inspections and tests have been performed and that such tests comply with the applicable requirements of this chapter. CLEARING. The removal of vegetation but shall not include normal vegetation pruning. COMPACTION. The consolidation of Fill material by mechanical means. CONTOUR GRADING. Grading which minimizes abrupt changes in the contour of graded areas in order to obtain a natural appearance. CRAWL SPACE. Areas under an Above Grade Structure or adjacent to a Basement with an interior finished ceiling height of no more than four feet. CUT. Excavation and removal of soil (or other substrate material) from a Site. DRIVEWAY. A way or route for use by vehicular traffic leading from a parking area or from a house, garage, or other structure to the Road. EROSION. The wearing away of the ground surface as a result of the movement of wind or water. EXCAVATION. Any act by which earth, sand, gravel, rock, or any other similar material is Cut into, dug, quarried, removed, displaced, relocated, or bulldozed or the conditions resulting there from. Adopted 5/1016 41 P as g ORD. 2016-575 Town of Woodside Municipal Code (Excerpt) FILL. A deposit of earth, sand, gravel, or rock materials. FOUNDATION PIERS. Vertical foundation members drilled or driven into soil or Bedrock. GRADE. The elevation of the ground surface. GRADE, EXISTING. The elevation of the ground surface prior to Excavation or Filling. GRADE, FINISHED. The elevation of the ground surface after the completion of all Grading. GRADING. An Excavation or Fill, or the Stockpiling or any combination thereof, or the conditions resulting from any Excavation or Fill. All Grading quantities shall be measured in their compacted state. GRADING, BASEMENT AND DAYLIGHTED BASEMENT. Basement size is determined by the maximum allowable basement grading. Grading quantities for Basements and Daylighted Basements are calculated to the exterior of the Basement structural walls. Basement and Daylighted Basement grading does not include the area required for any over -excavation required to construct the Basement or Daylighted Basement. Basement and Daylighted Basement Grading is calculated using the formula in Section 151.22.C.1. Basement and Daylighted Basement Grading is not included in Site Grading. GRADING, SITE. The process of adjusting the slope and elevation, excluding any grading listed in Sections 151.20.A.11 and 151.20.B. IMPERVIOUS AREA. Material that is not permeable by water or other fluids. Material that functions as a barrier to water infiltration into the soil (e.g., most concrete, asphalt, tile, and plastic lining). grading. IMPORTED MATERIAL. Earth material acquired from an off-site location for use in on-site KEYWAY. A Benched area Cut into subsurface materials intended to support Fill. NATURAL STATE. Natural State is the condition of land with no Grading, terrain alteration, keeping of livestock*, or removal of natural vegetation. Natural State areas include all natural features such as stream zones, rock outcrops, ridgelines, drainage swales, and areas of significant natural vegetation. No Grading or other disturbance is permitted (except as may be required for public safety or the development of Town designated trails). *Reference WMC § 115.12, Private Stable Regulations, for further details on keeping of horses. NATURAL STATE RESTORATION AREAS: Natural State Restoration Areas are previously disturbed areas where Grading and restoration are allowed as part of the Site Development Permit, to restore a Site or portion thereof, to its natural, pre -development era condition, or to restore a Site following land movement or other disturbance and/or climate related phenomena. OWNER. The individual, firm, partnership, association, trustee, or corporation who or which: Adopted 5/1016 51 P as g ORD. 2016-575 7) b) Design. All Site Grading shall be properly contoured, result in natural appearing land forms specific to the site, and minimize abrupt grade changes; and, c) Natural State Restoration. Natural State Restoration shall be accomplished to the maximum extent practicable. Entitlement Expiration. Any approval by the Town Engineer, Planning Director or Planning Commission, given pursuant to the provisions of this Chapter 151 shall lapse and shall become null and void two years following the date on which the approval became effective, unless, prior to the expiration of two years, a site development permit has been issued. Approvals may be extended for an additional period of one year provided that, prior to the expiration of the initial two year approval period, an application for the renewal of the approval is filed with the Planning Director. The Planning Director may grant an extension for a period not exceeding one year where no change in conditions or requirements has occurred, but an application involving a change deemed to be significant by the Planning Director shall be treated as a new application, subject to all the provisions of this chapter. 8) Application Inactivity. Any Planning application which has been incomplete for six or more months shall be considered inactive. The Planning Director shall notify applicants of such status by letter and provide 60 days to bring the application to complete status. If the application has not achieved complete status to the satisfaction of the Planning Director within this 60 day period, the applicant shall be refunded fees as specified by the Town's fee schedule and the application shall be closed. 75 Code, § 7-4.10) (Ord. 1984-317, effective 4-12-84; Am. Ord. 2014-564, effective 12-1-14) C) Basement and Daylighted Basement Grading. Grading quantities for Basements and Daylighted Basements shall be calculated as the exterior of the Basement structural walls. The maximum permitted Grading for a Basement shall be as follows in Table 1 below (no Grading Exceptions are permitted to Table 1). Table 1— Maximum Grading for Basements and Daylighted Basements* Zoning District Maximum Cubic Yards of Grading R-1, SR, RR, and all SCP The maximum residence size allowed for the property without an exception multiplied by 12 and divided by 27. CC The maximum building coverage allowed for the property multiplied by 12 and divided by 27. All OS The Total Floor Area allowed for the property or 6,000 square feet, whichever is less, multiplied by 12 and divided by 27. Adopted 5/1016 111 P as g ORD. 2016-575 The maximum cubic yards of grading for basements is calculated as the square footage (the footprint) times 12 (a depth), divided by 27 (to convert cubic feet to cubic yards). This is a volume calculation, therefore basements with greater depths have smaller footprints. 1) Calculation of Basement and Daylighted Basement Grading. Basement and Daylighted Basement Grading shall be calculated to the exterior structural walls located below Existing Grade or Finished Grade, whichever is lower. When calculations of an existing Basement(s) and Daylighted Basement(s) Grading is needed to determine the remaining allowable Basement(s) and Daylighted Basement(s), or when Grading for a site and construction plans are not available, the existing Basement and Daylighted Basement Grading shall be calculated as the interior finished dimensions, plus an assumed factor of 12 inches for all structural walls. 2) Means and Methods for Basement and Daylighted Basement Grading. Over -excavation for Basement and Daylighted Basement Grading shall be minimized to the greatest extent practicable. The means and methods for over -excavation for Basement and Daylighted Basement Grading exceeding eight feet shall require the review and approval of the Town Engineer and Planning Director." 75 Code, § 7-4.10) (Ord. 1984-317, effective 4-12-84) 151.23 REVIEW CRITERIA. The following factors shall be considered by the Town in its review of any application for a Site Development Permit, as indicated in § 151.20: A) The degree of saturation of the Fill and unsupported Cuts by water, both natural and domestic; B) The runoff of surface waters which have a potential to produce Erosion, siltation, and other adverse impacts on stream corridors or flood plains; C) The subsurface conditions, such as the rock strata and faults; D) The nature and type of the soil or rock; E) The effect upon the potential for future subdivision design; F) The visual relationships with other development in the vicinity of the Site; G) The relationship of the proposed Site Development to the character of the surrounding community; H) The capability of proposed slopes to be landscaped; 1) Unnecessary scarring of the natural landscape through the proposed Grading or removal of vegetation; J) Proper contouring of Grading to result in natural appearing land forms specific to the Site and minimize abrupt grade changes; Adopted 5/1016 121 P a g ORD. 2016-575 4) Surface preparation. The ground surface shall be prepared to receive the Fill by removing vegetation, topsoil, and other unsuitable materials and shall be scarified to provide a bond with new Fill. Where slopes are steeper than five to one, and the height is greater than five feet, benching or keying into sound Bedrock or other component material as determined by the Soils Engineer may be required. 5) Compaction of Fills. All Fills intended to support buildings or structures or where otherwise required to be compacted for stability of material shall be compacted, inspected, and tested in accordance with the approved geotechnical report. Where no geotechnical report exists, the following provisions shall apply: a) Surface preparation. The natural ground surface shall be prepared by the removal of topsoil and vegetation and, if necessary, shall be graded to a series of terraces. b) Moisture control. The moisture content of the Fill material shall be controlled at the time of spreading and Compaction to obtain the required maximum density. c) Compaction density. The Fill material shall be compacted to a relative Compaction density of not less than 90%, determined by the current ASTM standard. 75 Code, § 7-4.08(c) - (e)) (Ord. 1984-317, effective 4-12-84) Penalty, see § 10.99 151.41 BASEMENTS. A) Development Standards. Basements shall meet the following development standards: 1) No more than 50% of the maximum allowable Basement Grading, pursuant to Section 151.22.C, shall take place beyond the footprint of an Above Grade Structure; 2) Any Basement not located under an Above Grade Structure or Impervious Area shall have at least two and one-half feet of soil between the Finished Grade and the top of the Basement structure; 3) Below grade patios and egress/light wells, in aggregate, shall comprise no more than 15% of the maximum allowable Basement Grading; 4) Below grade Tunnels, in aggregate, shall comprise no more than 15% of the maximum allowable Basement Grading; 5) All Basements shall meet the required setbacks, except Basements beneath nonconforming structures, which may encroach into the required setbacks so long as that portion of the newly constructed Basement located in the setback does not exceed the footprint of the nonconforming structure. Egress/light Adopted 5/1016 151 Page ORD. 2016-575 wells which encroach into setbacks shall be sized to the minimum required by the California Residential Code (CRC) and/or California Building Code (CBC), whichever is applicable; 6) All Grading for Basements, egress/light wells, and below grade Tunnels shall adhere to Section 151.40.B.2; 7) The maximum interior finished height of a Basement shall be 20 feet; and, 8) All Tunnels shall be a maximum of eight feet wide in interior finished width, and nine feet high in interior finished height. Vehicular Tunnels (Tunnels leading to above or below grade vehicular parking) shall be excluded from this requirement. B) All portions of Basements located below grade shall not count towards Total Floor Area pursuant to Section 153.055. 151.42 SPORT COURTS AND SWIMMING POOLS. Maximum Cuts and Fills. Cuts and Fills for such accessory uses as sport courts and decking or terraces around swimming pools shall not exceed a height of six feet measured vertically from the toe to the top of the slope. ('75 Code, § 7-4.08(f)) (Ord. 1984-317, effective 4-12-84) Penalty, see § 10.99 151.43 DRAINAGE. Adequate provisions shall be made to dispose of surface waters and to prevent such surface waters from damaging the face of an Excavation or any portion of a Fill in accordance with the 1978 Town Storm Drain Master Plan and any subsequent revisions, and the following: A) Subsurface drainage. Cut and Fill slopes shall be provided with subsurface drainage as necessary for stability. B) Disposal. All drainage facilities shall be designed to carry waters to the nearest practicable drainage way approved by the Town Engineer as a safe place to discharge such waters. The Erosion of ground in the area of discharge shall be prevented by the installation of downdrains, retention basins, or other devices. C) Building pads. Building pads and all finished Grading shall comply with the drainage slope gradient required by the Building Code. If it is not practical to slope the finish grade away from the building, alternative methods may be approved by the Town Engineer. Surface drainage shall be toward approved drainage facilities to the satisfaction of the Town Engineer. Building pads, if necessary, shall be protected by berms, walls, Fills, or trenches which drain to a protected outlet. D) Drainfields. The Site drainage system shall be designed and constructed so that surface drainage shall not cross septic tank drainfields. Interceptor trenches or curtain drains may be used if approved by the County Environmental Health Officer and Town Engineer. E) Driveways. To prevent Erosion and ponding on the roadside and Road surface, all Driveways shall have a minimum cross slope of 3% or as approved by the Town Adopted 5/1016 161 P a g ORD. 2016-575