HomeMy WebLinkAboutCity Council Resolution 26-058, Deny appeal 14486 Oak PlaceRESOLUTION NO. 26-058
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
SARATOGA DENYING APPEAL APCC26-0004 AND APPROVING
A TENTATIVE PARCEL MAP AT 14486 OAK PLACE (APN 397-22-
005) AND FINDING THE PROJECT TO BE STATUTORILY
EXEMPT FROM THE CALIFORNIA ENVIRONMENTAL
QUALITY ACT PURSUANT TO PUBLIC RESOURCES CODE
21080.66 (Assembly Bill 130)
WHEREAS, on March 19, 2024, Deepak Chandani (Applicant), submitted a preliminary
application (CPX24-0011) for a Development Application and a Tentative Map to subdivide into
three lots an existing 6,750 sq. ft. parcel located at 14486 Oak Place. The new lots will range in
size from 1,708 - 2,742 square feet. Each of the three lots will include a three-story single-
family residence ranging in size from 2,346 – 2,489 square feet, including a 635 square foot
attached accessory dwelling unit (ADU) within one of the dwelling units. Two protected trees
are proposed for removal; and
WHEREAS, the California Legislature adopted the Housing Accountability Act (HAA) to
“significantly increase the approval and construction of new housing for all economic segments of
California’s communities by meaningfully and effectively curbing the capability of local
governments to deny, reduce the density for, or render infeasible housing development projects…”;
and
WHEREAS, the Builder’s Remedy is a provision of the HAA that is applicable to
qualifying housing development projects when a preliminary application is submitted after the
State’s deadline for Housing Element adoption and before the City adopted a substantially
compliant Housing Element; and
WHEREAS, the preliminary application was submitted before the City adopted a
substantially compliant General Plan Housing Element, and the project qualifies as housing for
mixed-income households. Therefore, the project qualifies as a Builder’s Remedy project pursuant
to the HAA; and
WHEREAS, the Builder’s Remedy provision of the HAA prohibits the City from relying
on subjective standards or on inconsistency with zoning and General Plan standards as a basis for
denial of a qualifying project; and
WHEREAS, the applicant submitted an Assembly Bill (AB) 130 Urban Infill Housing
CEQA Exemption checklist and supporting documentation to evaluate whether the project
meets the criteria to qualify for a CEQA exemption under Public Resources Code section
21080.66. The City contracted with the environmental consulting firm Michael Baker
International (MBI) to advise City Staff and to conduct a peer review of the AB 130
exemption documentation; and it is the opinion of staff that the analysis and conclusions
contained within the application are correct, the project satisfies all the conditions of AB 130,
and that the project is eligible for a statutory CEQA exemption pursuant to section 21080.66
of the Public Resources Code.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 2
WHEREAS, on May 13, 2026, the Planning Commission opened, and then continued, the
public hearing to allow further study of the project site’s eligibility for the AB 130 exemption; and
WHEREAS, on July 8, 2026, the Planning Commission re-opened the continued public
hearing, received public comments on the project, and duly considered those comments and the
materials in the staff report; and voted to approve the project subject to conditions of approval;
and
WHEREAS, on July 17, 2026, an appeal to the City Council (APCC26-0004) of the
Planning Commission’s decision to approve the application was filed by Ram Jagadeesan
(“Appellant”)
WHEREAS, on September 16, 2026, following a duly noticed public hearing where the
City Council conducted a de novo review of the appeal, at which all interested parties were given
a full opportunity to be heard and to present evidence, the City Council considered this resolution,
the exemption, and all pertinent maps, and other materials, exhibits, and evidence presented by
City Staff, the applicant, and other interested parties; and
NOW THEREFORE, the City Council of the City of Saratoga hereby finds,
determines and resolves as follows:
1. Denies the Appellant’s appeal of the Planning Commission’s decision to approve the
project.
2. Determines that the recitals set forth above are true and correct and incorporated
herein by reference.
3. Determines that the project qualifies for an AB 130 Exemption per section 21080.66
of the Public Resources Code and is statutorily exempt from CEQA review
4. Pursuant to Saratoga City Code section 14-20.070, the City of Saratoga City Council
hereby approves the Tentative Map for CPX24-0011 based on the finding set forth in
Exhibit 1 and subject to the Conditions of Approval attached hereto as Exhibit 2
5. Pursuant to Saratoga City Code section 15-45.080, the City of Saratoga City Council
hereby grants Design Review approval of CPX24-0011 located at 14486 Oak Place
based on the Design Review findings set forth in Exhibit 1 and subject to the
Conditions of Approval attached hereto as Exhibit 2.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 3
The above and foregoing resolution was passed and adopted at a regular meeting of the Saratoga
City Council held on the 16th day of September 2026 by the following vote:
AYES: COUNCIL MEMBERS AFTAB, FITZSIMMONS, ZHAO, VICE MAYOR
WALIA, MAYOR PAGE
NOES:
ABSENT:
ABSTAIN:
______________________________
Chuck Page, Mayor
ATTEST:
____________________________
Britt Avrit, MMC, City Clerk
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 4
Exhibit 1
FINDINGS FOR APPROVAL
APPLICATION NO. CPX24-0011
14486 OAK PLACE
(APN 397-22-005)
Tentative Map Findings
The City Code provides that the City shall not approve any tentative map if it makes any of the
following ten findings [City Code Section 14-20.070(b)]. The following describes evidence in
the record supporting the City Council’s determination not to make each of the findings. The
findings are written in the negative, consistent with the Subdivision Map Act.
1. That the proposed map is not consistent with the General Plan and any applicable
specific plans. The project is consistent with some provisions of the General Plan but is not
consistent with the General Plan designation of Medium Density Residential (M-10): the
project proposes 26.7 dwelling units per acre where the M-10 designation is defined as 4.35
dwelling units per net acre. However, under the Builder’s Remedy provisions of the HAA,
such inconsistency may not be the basis for disapproving the tentative map. Based on state
law and evidence in the record, the City Council does not make this finding for denial;
thereby supporting approval of the Project.
2. That the design or improvements of the proposed subdivision are not consistent with the
General Plan and any applicable specific plan. The project is consistent with some
provisions of the General Plan. The subdivision is consistent with Land Use Element Policy
LU-1.1: Affirm that the city shall continue to be predominately a community of single-
family detached residences. The design or improvements of the proposed subdivision are
not consistent with the General Plan in that the maximum dwelling units per acre in the M-
10 designation is 4.35 dwelling units per acre while the project proposes 26.7 dwelling units
per acre. However, under the Builder’s Remedy provisions of the HAA, such inconsistency
may not be the basis for disapproving the tentative map. Based on state law and evidence in
the record, the City Council does not make this finding for denial; thereby supporting
approval of the Project.
3. That the site is not physically suitable for the type of development proposed. The site is
suitable for the type of development proposed in that the site already contains residential
development. The existing conditions are such that there are no physical features including
topography/slope, location, or surroundings that may hinder the proposed development on
the site. Based on state law and evidence in the record, the City Council does not make this
finding for denial; thereby supporting approval of the Project.
4. The site is not physically suitable for the proposed density of development. The site is
physically suitable for the proposed density of development of 26.7 dwelling units per acre
in that the site does not have any physical features including topography/slope, location, or
surroundings that would hinder the development of four units. Based on state law and
evidence in the record, the City Council does not make this finding for denial; thereby
supporting approval of the Project.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 5
5. That the design of the subdivision is likely to cause substantial environmental damage or
substantially and avoidably injure fish or wildlife or their habitat. The design of the
subdivision is not likely to cause substantial environmental damage or substantially and
avoidably injure fish or wildlife or their habitat in that the site is already developed, it is
surrounded by urban uses, and it does not contain habitat for protected fish or wildlife
habitat. Based on state law and evidence in the record, the City Council does not make this
finding for denial; thereby supporting approval of the Project.
6. That the design of the subdivision is likely to cause serious health or safety problems. The
design of the subdivision is not likely to cause serious health or safety problems in that the
proposed project has been reviewed by the Santa Clara County Fire Department, City of
Saratoga Planning Department, Public Works, and Engineering. The project site is not
within a ground movement potential zone or liquefaction zone which would pose
geotechnical risks. All structural improvements to the property will be reviewed by the
Community Development Department’s Building Division. Based on state law and evidence
in the record, the City Council does not make this finding for denial; thereby supporting
approval of the Project.
7. That the design of the subdivision will conflict with easements acquired by the public at
large for access or use. The design of the subdivision would not conflict with easements for
access or use. There are no access or other easements in the area that would be affected by
the subdivision. Based on state law and evidence in the record, the City Council does not
make this finding for denial; thereby supporting approval of the Project.
8. That a proposed subdivision of land which is subject to a contract executed pursuant to
the Williamson Act will result in the creation of parcels to sustain their agricultural use.
The project site is not subject to a Williamson Act contract. Therefore, the City Council
does not make this finding for denial; thereby supporting approval of the Project.
9. That the discharge of waste from the proposed subdivision into an existing community
sewer system would result in violation of existing requirements. The discharge of waste
from the proposed subdivision into an existing community sewer system would not result in
violation of existing requirements in that sewer system operated by the West Valley
Sanitary District would have capacity to process waste discharge associated with the
project. Based on state law and evidence in the record, the City Council does not make this
finding for denial; thereby supporting approval of the Project.
10. That the City Engineer has not found that the subdivision as proposed meets the
requirements of Section 14-20.050(b)(2) nor identified conditions or improvements that
would ensure the development of the subdivision meets the requirements of that section.
The City Engineer has found that the project meets the requirements of Section 14-
20.050(b)(2) and has provided conditions of approval. Based on state law and evidence in
the record, the City Council does not make this finding for denial; thereby supporting
approval of the Project.
Design Review Findings
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 6
The findings required for Design Review Approval pursuant to City Code Section Article 15-
45.080 are set forth below:
1. Site development follows the natural contours of the site, minimizes grading, and is
appropriate given the property’s natural constraints. This finding can be made in the
affirmative in that the site is relatively level with an average grade of 9.8% from the front of
the property to the rear. The development of the site with three single-family structures and
attached ADU would follow this natural grade such that minimal grading would be involved.
The development is appropriate to the property’s natural constraints.
2. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If
constraints exist on the property, the number of protected trees, heritage trees, and native
trees approved for removal shall be reduced to an absolute minimum. Removal of any
smaller oak trees deemed to be in good health by the City Arborist shall be minimized
using the criteria set forth in Section 15-50.080. This finding can be made in the
affirmative. The project arborist inventoried a total of four trees on the site which are
protected by the City’s tree regulations. The City Arborist must make specific findings
according to the tree regulations contained in City Code Section 15-50.080 whenever a
protected tree is proposed for removal as part of a project. The City Arborist determined that
two protected trees would conflict with the project and meet the City’s criteria allowing them
to be removed and replaced. Replacement trees equaling $11,530 in value are to be planted
prior to final inspection. An Arborist Report and Tree Protection Plan have been approved
for the retained protected trees, and tree protection fencing will be required to be installed
prior to construction.
3. The height of the structure, its location on the site, and its architectural elements are
designed to avoid unreasonable impacts to the privacy of adjoining properties and to
community viewsheds. There are no identified community viewsheds in the vicinity of the
project. The project may impact the privacy of the existing homes located adjacent to the
development, due to potential views from second and third story windows and balconies,
facilitated by the height and setbacks of the structures, which do not comply with the
standards of the R-1-10,000 zoning district. The project design does follow several of the
City’s single-family design standards for privacy including proposing a 6-foot fence along
the property line, no floor to ceiling windows, and a sill height of 42 inches or greater for the
majority of second and third story windows. The California Building Code requires all
bedrooms on upper floors to have a minimum window opening size of 5.7 square feet for
emergency egress. As many of the privacy impacts and design standard conformance issues
are related to the height, setbacks, and small lot size, which precludes shifting the building
footprint, it would not be possible to remedy privacy issues without reducing the project’s
overall proposed density or size, and thus its feasibility. Under the Builder’s Remedy
provisions of the HAA, such inconsistency may not be the basis for denying Design Review
for the project, or for imposing conditions that reduce the project’s feasibility; therefore, staff
recommends approval.
4. The overall mass and height of the structure, and its architectural elements are in scale
with the structure itself and with the neighborhood. The proposed project is not consistent
with neighborhood massing, height, and scale. Each of the three single-family homes have
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 7
similar first, second and third story setbacks with little articulation to break up the
appearance of massing, which reinforces the vertical appearance of each structure. While
several of the City’s single-family design standards for massing and scale are met including
regulations on multi-story plate height and roof forms, many other standards are not met
including stepped back second stories and vertical plans. Furthermore, the height and story
count of the homes exceed what is allowed in the zoning district and what is found in the
neighborhood. However, due to the small lot size, these height and mass impacts would not
be possible to be remedied without reducing the project’s overall proposed density or size,
and thus its feasibility. Under the Builder’s Remedy provisions of the HAA, such
inconsistency may not be the basis for denying Design Review for the project, or for
reducing the project’s feasibility; therefore, staff recommends approval.
5. The landscape design minimizes hardscape in the front setback area and contains
elements that are complementary to the neighborhood streetscape. The landscape design
would meet a majority of the City’s single-family design standards for site design including
fence design, visibility of solar panels and utilities, paving, and landscaping. However, the
proposed home on the front lot encroaches into the R-1-10,000 front setback area. This
encroachment and the driveway together surpass the 50% maximum impervious coverage
allowed by the City Code in the front setback area. The reduced setback of the front home
and the greater height also pose a discrepancy with the neighborhood streetscape. Reducing
these impacts would require lowering the proposed height or increasing the proposed
setbacks which would reduce the project’s overall size and density given the small lot size
and the lack of alternative layouts. Thus, modifications to address this finding would reduce
the project’s feasibility. Under the Builder’s Remedy provisions of the HAA, such
inconsistency may not be the basis for denying Design Review for the project, or for
reducing the project’s feasibility; therefore, staff recommends approval.
6. The design of the structure and the site development plan is consistent with the Residential
Design Handbook, pursuant to Section 15-45.055. The proposed project is not consistent
with several applicable design policies and techniques from the Residential Design
Handbook regarding building massing, height, and scale as well as those pertaining to
privacy and setbacks. However, under the Builder’s Remedy provisions of the HAA, such
inconsistency may not be the basis for denying Design Review for the project; therefore, staff
recommends approval.
7. On hillside lots, the location and the design of the structure avoid unreasonable impacts to
ridgelines, significant hillside features, community viewsheds, and is in compliance
with Section 15-13.100. This finding is not applicable to the project because the average
slope of the site is less than 10% therefore the site is not classified as a hillside lot nor is it
located within the Hillside Residential Zoning District.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 8
Exhibit 2
CONDITIONS OF APPROVAL
APPLICATION NO. CPX24-0011
14486 OAK PLACE
(APN 397-22-005)
A. GENERAL
1. Conformance with Approved Plans. The approval for CPX24-0011/ENV25-0018 is
granted to subdivide into three lots and construct three single-family homes and one
accessory dwelling unit and associated site improvements on an existing 6,750-square foot
parcel located on Oak Place, Saratoga, California, Assessor Parcel No. 397-22-005, as shown
on Project Plans dated September 12, 2024 prepared by Openscope Studio, Inc and Sterling
Consultants for Deepak Chandani and approved by the Planning Commission on July 8, 2026
consisting of 13 sheets (the “Approved Plans”).
Build-out of the project shall conform to the approved plans, except as otherwise specified in
these conditions. Prior to Building Permit submittal, the applicant shall notify the Planning
Division in writing of any proposed adjustment or modification to the plans, and shall
include a clouded set of the approved plans highlighting the changes, which shall be
considered by the Community Development Director or designee, may require separate
discretionary approval, and shall conform to all City, State, and Federal requirements,
including subsequent City Code requirements or policies adopted by the City Council. No
proposed adjustment or modification shall take effect unless approved.
2. Where there are differences between these Conditions of Approval and the 2040 General
Plan EIR Mitigation Measures, the stricter requirement shall be applicable.
3. Amounts Due. The Applicant will be electronically mailed a statement after this approval is
duly executed, containing a statement of all current amounts due to the City in connection
with this application, including all consultant fees (collectively “processing fees”). This
approval or permit shall expire sixty (60) days after the date said notice is electronically
mailed if all processing fees contained in the notice have not been paid in full. No Zoning
Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies
that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of
$500 is maintained, to account for invoices received from external agencies and consultants,
post entitlement).
4. Permit Expiration. Except for subdivisions, this approval shall expire 24 months from the
date on which the approval became effective, unless prior to such expiration date a building
permit is issued for the improvements constituting the subject of this approval and
construction thereof commenced and progressed diligently toward completion by
maintaining an active Building Permit with ongoing inspections, or a certificate of occupancy
issued for such improvements. This approval may be extended for a single period of time not
exceeding twelve months. The application for extension shall be filed at least 60 days prior to
the expiration date and shall be accompanied by the payment of a fee in accordance with the
City’s adopted Fee Schedule. A public hearing shall be conducted on the application for
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 9
extension in accordance with City Code Section 15-46.050. For subdivisions, the tentative
map shall expire in accordance with State law.
5. Regulatory Compliance. The Project shall comply with all applicable regulations of the
State, County, City and/or other governmental agencies having jurisdiction.
6. Revocation/Enforcement. If Applicant, property owner, or tenant fails to comply with any
of the conditions of this permit, the Applicant and property owner shall be subject to permit
revocation or enforcement actions pursuant to the City Code. All costs associated with any
such actions shall be the responsibility of the property owner / Applicant.
7. Indemnification. Applicant shall sign the “Indemnification Agreement” attached herein as
Exhibit 4.
B. COMMUNITY DEVELOPMENT
A. Community Development
When
Required/Time
for Compliance
Condition of Approval
Ongoing CD-1. The development shall be located and constructed to include those
features, and only those features as shown on the plans approved by the Planning
Commission and on file with the Community Development Department (Exhibit
“A”). All proposed changes to the approved plans must be submitted in writing
with plans showing the changes, including a clouded set of plans highlighting the
changes. Such changes shall be subject to approval in accordance with City Code.
At the time of
first building
permit submittal
CD-2. Building Submittal. Complete construction plans shall be submitted to the
Building Division. These plans shall be subject to review and approval by the
City. The construction plans (“the Building Submittal”) shall, at a minimum
include the following:
a) Architectural drawings and other plan sheets consistent with Exhibit A
b) Arborist report dated September 24, 2024.
c) The signed and dated Resolution approving the Project, printed onto separate
construction plan pages.
d) Additional plan pages identified in these Conditions of Approval.
e) All additional drawings, plans, maps, reports, notes, and/or materials required
by the Building Division, including those listed on a building permit submittal
building division checklist, website, or as applicable.
At the time of
first building
permit submittal
CD-3. Lighting Plan. The Building Submittal shall include a Lighting Plan for
the exterior and landscaped areas. This plan should include photometric contours,
manufacturer’s specifications on the fixtures, and mounting heights. Proposed
exterior lighting shall be limited to full-cut-off & shielded fixtures with
downward directed illumination so as not to shine on adjacent properties or public
right-of-way. All proposed exterior lighting shall be designed to limit illumination
to the site and avoid creating glare impacts to surrounding properties. Such
lighting shall not conflict with drainage plans, landscape plans, tree locations,
parking spaces, or any other such land use concerns.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 10
At the time of
first building
permit submittal
CD-4. Landscaping and Irrigation Plan. The Building Submittal shall include a
final landscaping and irrigation plan, that implements City Arborist and
stormwater requirements and demonstrates how the project complies with the
State Water Efficient Landscape Ordinance and shall take into account the
following:
a) To the extent feasible, landscaping shall be designed and operated to treat
stormwater runoff by incorporating elements that collect, detain and infiltrate
runoff. In areas that provide detention of water, plants that are tolerant of
saturated soil conditions and prolong exposure to water shall be specified.
b) To the extent feasible, pest resistant landscaping plants shall be used
throughout the landscaped area, especially along any hardscape area.
c) Plant materials selected shall be appropriate to site specific characteristics
such as soil type, topography, climate, amount and timing of sunlight,
prevailing winds, rainfall, air movement, patterns of land use, ecological
consistency and plant interactions to ensure successful establishment.
At the time of
first building
permit submittal
CD-5. Fencing and Walls. The Building Submittal shall include all proposed
fencing and walls, including their height and materials, and all such fencing and
walls shall comply with City Code.
At the time of
first building
permit submittal
CD-6. Certification of Building Permit Plans. The Building Submittal shall
include a letter from the project architect, certifying that the architectural design
shown in the building permit plans match, Exhibit A. Any changes must be
clearly noted and shall be subject to Condition CD-1 above. The project architect
shall also certify that the structural plans are consistent with the architectural
plans. In the event of a discrepancy between the structural plans` and the
architectural plans, the architectural plans shall take precedence, and revised
structural drawings shall be submitted to the Building Division.
At the time of
first building
permit submittal
CD-7. Conditions of Approval Plan Sheet. The Building Submittal shall include
a plan sheet(s) that includes a reproduction of all mitigation measures and
conditions of approval, as adopted by the Planning Commission.
Prior to issuance
of any grading
or building
permit
CD-8. Existing Violations. Prior to issuance of grading or building permits,
Applicant/owner shall correct all violations of the City Code, if any, existing on
the project property.
Prior to issuance
of first building
or grading
permit
CD-9. Construction Management Plan. The Building Submittal shall include a
final Construction Management Plan for the project which includes, but is not
limited to, the following:
a) Proposed construction worker parking area.
b) Proposed construction hours that are consistent with City Code.
c) Proposed construction/delivery vehicle staging or parking areas.
d) Proposed traffic control plan with traffic control measures, any street closure,
hours for delivery/earth moving or hauling, etc. The traffic control plan
should prevent congestion, traffic conflicts, and potential safety issues by
scheduling any deliveries, earth moving or hauling activities to avoid peak
commute hours, to the extent feasible.
e) Proposed construction material staging/storage areas.
f) Location of project construction sign outlining permitted construction work
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 11
hours, name of project contractor and the contact information for both
homeowner and contractor. The project construction sign should be designed
to be readable from 5 feet away.
All parking, storage, and staging areas shall be located on the Project site and
shall be sited in a manner that minimizes adverse effects on traffic circulation and
adjoining properties.
Prior to
commencement
of any
earthwork or
grading
activities
CD-10. Pre-Construction Meeting. Applicant shall arrange a pre-construction
meeting, attended by all individuals needed to ensure building division processes,
conditions of approval, and mitigation measures are understood and met. The
pre-construction meeting shall be held at least two full City business days prior to
the start of any earthwork activities.
Upon
completion of
rough grading
work and at the
final completion
of the project
CD-11. Final Grading Reports. Upon completion of the rough grading work and
at the final completion of the project, the final grading reports are to be submitted
to the City per section 16-17.150 of the City Code.
Ongoing during
construction
CD-12. Construction Air Quality Controls. To minimize potential construction-
related impacts to air quality, Applicant shall require all construction contractors
to implement the basic construction mitigation measures recommended by the
Bay Area Air Quality Management District (BAAQMD) and shall include the
following language on any grading, site work, and construction plans issued for
the project site. “During earth-moving, grading, and construction activities,
Applicant shall implement the following basic control measures at the
construction site:
a. All exposed surfaces (e.g. parking areas, staging areas, soil piles, graded
areas, and unpaved access roads) shall be watered two times per day;
b. All haul trucks transporting soil, sand, or other loose material onsite or offsite
shall be covered;
c. All visible mud or dirt tracked out onto adjacent public roads shall be
removed using wet power vacuum street sweepers at least once per day. The
use of dry power sweeping is prohibited;
d. All vehicle speeds on unpaved roads or pathways shall be limited to 15 miles
per hour;
e. All roadways, driveways, and sidewalks to be paved shall be completed as
soon as possible. Building pads shall be laid as soon as possible after grading
unless seeding or soil binders are used;
f. Idling times shall be minimized either by shutting equipment off when not in
use or reducing the maximum idling time to 5 minutes (as required by the
California airborne toxics control measure Title 13, Section 2485 of California
Code of Regulations [CCR]). Clear signage shall be provided for construction
workers at all access points;
g. All construction equipment shall be maintained and properly tuned in
accordance with manufacturer’s specifications. All equipment shall be
checked by a certified visible emissions evaluator; and
h. Post a publicly visible sign with the telephone number and person to contact at
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 12
the lead agency regarding dust complaints. This person shall respond and take
corrective action within 48 hours. The Air District’s phone number shall also
be visible to ensure compliance with applicable regulations.
Ongoing during
construction
CD-13. Unknown Well. If a previously unknown well is encountered during
project implementation, it shall be properly destroyed under a permit obtained
from the Santa Clara Valley Water District (Valley Water) or registered with
Valley Water and protected from damage.
Ongoing during
construction
CD-14. Discarded Materials Containers and Disposal. All collection of
discarded materials and construction and demolition debris shall be in accordance
with City Code section 7-05.080. West Valley Collection & Recycling is the
exclusive roll-off and debris box provider for the City of Saratoga.
Prior to first
foundation
inspection
CD-15. Setback Certification. A Licensed Land Surveyor shall provide a written
certification that all building setbacks are per the approved plans.
Prior to final
inspection
CD-16. Underground Utilities. All new/upgraded utilities shall be installed
underground per section 15-80.040 of the City Code. Tree preservation measures
shall be implemented in conformance with Arborist conditions of approval, as
applicable.
Prior to final
inspection
CD-17. Building Height Certification. All proposed buildings shall have the
building height certified by a licensed architect.
Prior to final
inspection
CD-18. Landscaping Installation / Bond. All landscaping shall be installed or a
bond satisfactory to the Community Development Department valued at 150% of
the estimated cost of the installation of such landscaping shall be provided to the
City.
Prior to final
inspection
CD-19. Water Efficient Landscape Certificate of Completion. A certificate of
completion, on such forms as may be prescribed, shall be filed with the
Community Development Department prior to final building permit approval,
demonstrating compliance with the Water Efficient Landscape Ordinance.
Prior to final
inspection
CD-20. Locking Mailbox. A locking mailbox approved for use by the U.S.
Postal service shall be installed and in compliance with City Code section 6-
25.030.
Project Specific
At the time of
first building
permit
submittal.
CP-1. MMRP Project Manager. The Applicant shall identify a Project Manager
responsible for ensuring compliance with the Mitigation Monitoring and
Reporting Program (MMRP) for the Project. The MMRP Project Manager shall
attend the pre-construction meeting and shall coordinate any mitigation
monitoring with the Community Development Director, or designee, prior to
issuance of a Zoning Clearance, Grading Permit, or Building Permit, whichever
comes first. The MMRP Project Manager shall ensure that mitigation measures
that must be implemented prior to submittal of building plans, have been
completed and reviewed by the Planning Division.
Prior to
commencement
of site work,
grading, or
CP-2. Project Website. Applicant shall establish and maintain a website that
outlines construction activities and expected schedule, project construction
updates, and provides phone numbers of the person responsible to answer
questions to residents. An emergency 24-hour phone number shall be included on
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 13
construction. the website as well as the number for a point of contact available on site at all
times during construction activities. This website shall be updated from time to
time to inform residents of upcoming project activities to the satisfaction of the
Project Planner.
Prior to
recordation of
the Final Map or
issuance of
building/grading
permits,
whichever
comes first
CP-3. Covenants, Conditions, and Restrictions: If any Conditions of Approval
imposed by the City on the Project will be implemented by a Homeowner’s
Association (“HOA”) or through a maintenance agreement among lot owner’s
within the subdivision, then the CC&Rs or maintenance agreement shall
demonstrate the HOA’s or parties’ authority and duty to implement those
conditions. A copy of the CC&Rs or agreement shall be provided to the City
Attorney for approval as to this requirement and may only be recorded after such
approval is granted.
Prior to
recordation of
the Final Map
CP-4. Park and Recreation Dedication and Fees. A fee in-lieu of parkland
dedication pursuant to City Code Section 14-25.080 or 15-58.020(h) shall be paid,
as established by the City's Adopted Fee Schedule.
Prior to issuance
of permits
CP-5. A Phase 1 ESA shall be completed by the applicant and submitted to the
City. If a recognized environmental condition is found to exist on-site, a
preliminary endangerment assessment must be taken to identify any risks
associated with (1) any on-site releases and (2) the potential for exposure of future
occupants to significant health hazards from any nearby property or activity. If an
on-site release is discovered, the release shall be removed or any significant
effects mitigated consistent with state and federal requirements before a certificate
of occupancy may be issued. If a potential for exposure to significant hazards
from surrounding properties or activities is found to exist, the effects of the
potential exposure shall be mitigated to levels required by current federal and
state statutory and regulatory standards before a certificate of occupancy may be
issued.
Prior to any
ground
disturbance
TCR-1. Tribal Cultural Resources Sensitivity Training: Prior to the beginning of
any ground disturbance, the applicant shall conduct a cultural resources sensitivity
and awareness training program for all construction personnel according to the
requirement below:
The training shall use the retained services of a qualified Ohlone Native American
representative and/or a qualified archaeological consultant
The training shall be received by all work crews, contractors, subcontractors, and
any personnel involved in ground-disturbing activities.
The training shall include:
Identification of potential tribal cultural resources (TCRs) and artifacts.
A review of the "Stop Work" protocol and legal requirements for resource
protection and notification.
Throughout the
construction
process
TCR-2. Native American and Archaeological Monitoring: The applicant shall
retain and compensate qualified monitors for all earth-moving and ground-
disturbing activities (including grading, trenching, and landscaping excavations).
Throughout the
construction
process
TCR-3. Inadvertent Discovery and Stop Work Protocol: Should any suspected
tribal cultural resources or human remains be encountered, the following protocol
shall be strictly enforced:
The project sponsor shall immediately notify tribe and shall immediately suspend
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 14
any soils-disturbing activities in the vicinity of the discovery until the Cultural
Monitor and a qualified archeological consultant from the Qualified
Archeological Consultants List have assessed the find and the respective parties
have determined whether and what additional measures should be undertaken
Throughout the
construction
process
TCR-4. Preservation in Place and Treatment of Resources: In accordance with
PRC Section 21080.66(b)(4)(B)(ii), tribal cultural resources shall be avoided and
preserved in place where feasible.
If it is determined in consult by the project sponsor, the archeological consultant,
and tribal representative that the preservation-in-place of the resource would be
both feasible and effective, the archeological consultant shall prepare a Resource
Preservation Plan in consultation with the tribal representative for implementation
during construction.
If it is determined in consult by the project sponsor, the archeological consultant,
and tribal representative that the preservation-in-place of the resource would not
be feasible then the archeological consultant in coordination with the tribal
representative shall conduct an archeological assessment to determine the
significance of the findings and determine whether it retains sufficient integrity to
warrant treatment. If it is determined to be a significant archeological resource,
the archeological consultant in coordination with the tribal representative shall
recommend archeological treatment to preserve data and values of the resource. If
an archeological interpretive, monitoring, and/or testing program is required, it
shall be consistent with standard guidelines for such programs and shall be
implemented immediately.
Interpretive Program: If it is determined, in consultation with the tribal
representative and the project sponsor, that preservation-in-place of the tribal
cultural resource is not a sufficient or feasible option, the project sponsor, in
consultation with local Native American representatives, shall prepare a Cultural
Resources Public Interpretation Plan (CRPIP) to guide the interpretive program.
The CRPIP shall be submitted for review and approval prior to implementation of
the program.
Upon approval of the CRPIP and prior to project occupancy, the interpretive
program shall be implemented by the project sponsor.
The project sponsor shall work with the tribal representative to identify the scope
of work by the tribal representative to fulfill the requirements of this mitigation
measure, which may include participation in preparation and review of
deliverables (e.g., plans, interpretive materials, artwork). Tribal representatives
shall be compensated for their work as identified in the agreed upon scope of
work.
Throughout the
construction
process
TCR-5. Discovery of Human Remains: In the event that human remains are
discovered, the Project Sponsor shall comply with State Health and Safety Code
Section 7050.5 and Public Resources Code Section 5097.98:
All work shall immediately stop within a 50-foot radius of the find and protection
shall be arranged until the remains until appropriate treatment and disposition
have been agreed upon and implemented in accordance with this section.
The project sponsor shall notify the Medical Examiner of the County in which the
job resides and the Tribe of the find.
If the remains are determined to be Native American, the Coroner shall notify the
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 15
Native American Heritage Commission (NAHC) within 24 hours and all
provisions of Public Resources Code 5097.98 will be followed.
Throughout the
construction
process
TCR-6. Cultural Resources Best Management Practices To demonstrate
compliance with General Plan Policy LU-12.8, LU-12.9, LU-12.d, and LU-12.e
and existing regulatory requirements as identified below, the following
construction practices and protocols shall be implemented:
A qualified Architectural Historian shall conduct a built environment assessment
of building, structures or objects that are 50 years of age or older based on the
criterion set forth in the National Register of Historic Places (NRHP), California
Register of Historic Resources (CRHR), and local designations criteria.
Continue to ensure that if construction or grading activities result in the discovery
of unique archaeological, prehistoric and/or paleontological resources, including
individual resources, fossils or assemblages of resources and/or fossils, all work
within 100 feet of the discovery shall cease and the Planning Department shall be
notified. The resources shall be examined by a qualified Archaeologist or
Paleontologist, and work may only resume when appropriate protections are in
place and are approved by the Planning Department.
B. City Arborist
When
Required/Time
for Compliance
Condition of Approval
Prior to and
during site
development
AR-1 All City Arborist requirements, dated September 24, 2024 and included
as Exhibit 3, are hereby adopted as conditions of approval and shall be
implemented as part of the approved plans.
C Engineering
When
Required/Time
for Compliance
Condition of Approval
At the time of
first building
permit submittal
ENG-1 Stormwater Information. The Building Submittal shall include a
current C3-Data-Form that calculates the amount of impervious surface
created by the development, including the existing impervious area, proposed
impervious area, and proposed pervious area. If the City determines that
the development is subject to the current National Pollutant Discharge
Elimination System Permit (“NPDES Permit”) issued to the City, the City
shall require the owner (applicant) to provide a stormwater treatment plan, as
described below.
Prior to issuance
of a Grading or
Building Permit
ENG-2 A final Stormwater Management Plan shall be submitted for review
and approval demonstrating how all storm water will be retained on-site and in
compliance with the NPDES Permit Standards. If not all stormwater can be
retained on-site due to topographic, soils or other constraints, and if complete
retention is not otherwise required by the NPDES Permit Standards, the
Project shall be designed to retain on-site the maximum reasonably feasible
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 16
amount of stormwater and to direct all excess stormwater away from adjoining
property and toward stormwater drains, drainageways, streets or road right-of-
ways and otherwise comply with the NPDES Permit Standards and applicable
City Codes.
During site
development
ENG-3 Disposition and treatment of stormwater shall comply with the
applicable requirements of the National Pollution Discharge Elimination
System ("NPDES") Permit issued to the City of Saratoga and the
implementation standards established by the Santa Clara Valley Urban Runoff
Pollution Prevention Program (collectively the "NPDES Permit Standards")
Prior to issuance
of a Grading or
Building Permit
ENG-4 For single-family home projects that create and/or replace between
2,500 SF and 10,000 SF of impervious surface, Owner / Applicant shall
provide the Small Projects Worksheet and implement at least one the (1) Low
Impact Development (LID) Site Design Measures listed on the form. The
Worksheet is available on the City’s Stormwater Pollution Prevention
webpage.
Prior to issuance
of a Grading or
Building Permit
ENG-5 Applicant / Owner shall obtain an encroachment permit for all
improvements in any City right-of-way or City easement including all new
utilities prior to commencement of the work to implement this Design Review.
Prior to and
during site
development.
ENG-6 All new/upgraded utilities shall be installed underground.
Prior to and
during site
development.
ENG-7 All building and construction related activities shall adhere to New
Development and Construction – Best Management Practices (BMPs) as
adopted by the City for the purpose of preventing storm water pollution. Prior
to issuance of any grading or building permits, Owner / Applicant shall
prepare an Erosion Control Plan implementing the following:
• Construction site inspection and control to prevent construction site
discharges of pollutants into the storm drains per approved.
• Year-round effective erosion control, run-on and run-off control,
sediment control, good site management, and non-storm water management
through all phases of construction (including, but not limited to, site grading,
building, and site finishing) until the site is fully stabilized by landscaping or
the installation of permanent erosion control measures is complete.
• Details for all erosion control measures.
Prior to and
during site
development.
ENG-8 City will conduct inspections to determine compliance and determine
the effectiveness of the BMPs in preventing the discharge of construction
pollutants into the storm drain. The owner shall be required to timely correct
all actual and potential discharges observed.
Prior to issuance
of any grading or
building permits
ENG-9 Owner / Applicant shall prepare a Grading and Drainage Plan. The
Grading and Drainage Plans shall conform to the Approved Development
Plans, as modified per these conditions of approval. The Grading and
Drainage Plans shall clearly indicate and/or implement the following:
a. On-site stormwater retention and pollution control, in compliance with
the Low Impact Development (LID) Site Design Measures listed on
the Small Project Worksheet.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 17
b. Show all drainage facilities, locations of downspouts and area drains,
path and direction of drainage swales and other surface or
underground drainage feature.
c. All hardscape and landscape features (labeled and detailed as needed).
d. Detailed grading information, including but not limited to pad and
finish floor elevations, trenching locations, accurate tree
canopy/dripline, and any other necessary details.
e. Positive drainage away from structures in conformance with the
current California Building Code and the City’s Municipal Code; and
away from property lines. Sufficient spot elevations shall be
provided. Slopes and direction of flow shall be clearly indicated.
f. A breakdown of new and replaced impervious areas for NPDES
requirements.
Prior to issuance
of any grading or
building permits
ENG-10 The Project soils engineer shall review and approve the design and
details of all drainage features infiltrating into the soils, such as, but not
limited to, the infiltration basin and pervious concrete/pavers.
Prior to issuance
of any grading or
building permits
ENG-11 Owner / Applicant shall prepare a Demolition Plan. The Demolition
Plan shall conform to the Approved Development Plans, as modified per these
conditions of approval.
Prior to issuance
of any grading or
building permits
ENG-12 Owner / Applicant shall prepare a Utility Plan showing utilities
serving the residential structures. Show existing and proposed mains/pipelines
and all connection points (sewer, water, power, etc.). If utilities are to remain,
and will not be capped or replaced, please add a note to that effect on the
plans. All new/upgraded utilities shall be installed underground. Utility
information may be combined with Grading and Drainage plan in a clear and
legible manner.
Prior to issuance
of a Grading or
Building Permit
ENG-13 Applicant / Owner shall secure all necessary permits from the City
and any other public agency, including utility providers, prior to
commencement of construction. Copies of permits other than those issued by
the City shall be provided to the City Engineer.
Prior to and
during site
development.
ENG-14 Applicant / Owner shall comply with all conditions regarding on-site
or off-site improvements as may be requested by other Agencies or Utility
Companies having jurisdiction over the Project site. Prior to issuance of City
permits, the applicant must present evidence of permit approval by any such
agencies, as required for any activities within jurisdictional areas of said
agencies.
Prior to issuance
of a Grading or
Building Permit
ENG-15 Applicant / Owner shall provide two hard copies and an electronic
copy of a Preliminary Title Report, dated within 90 days, to the City Engineer.
The electronic copy shall include hyperlinks to all listed encumbrances.
Prior to
foundation
ENG-16 The LLS of record shall provide a written certification that all
building setbacks are per the approved plans.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 18
inspection by the
City
Prior to issuance
of a Grading or
Building Permit
ENG-17 As a condition of this Approval, Owner and Applicant hereby agree
to defend, indemnify, and hold the City and its officers, officials, boards,
commissions, employees, agents, and volunteers harmless from and against:
a. any and all claims, actions, or proceedings to attack, set aside, void or
annul any action on the subject application, or any of the proceedings,
acts or determinations taken, done, or made prior to said action; and
b. any and all claims, demands, actions, expenses, or liabilities arising
from or in any manner relating to the performance of such construction,
installation, alteration or grading work by the Owner and/or Applicant,
their successors, or by any person acting on their behalf.
In addition, prior to any Zoning Clearance from the Community Development
Director. Owner and Applicant shall execute a separate agreement containing
the details of this required Agreement to Indemnify, Hold Harmless and
Defend, which shall be subject to prior approval as to form and content by the
City Attorney
D. Public Works
When
Required/ Time
for Compliance
Condition of Approval
Prior to Final
Inspection
PWDR-1. Damages to driveway approach, curb and gutter, public streets, or
other public improvements during construction shall be repaired prior to final
inspection.
During site
development
PWDR-2. Applicant / Owner shall maintain the streets, sidewalks and other
right-of-way as well as adjacent properties, both public and private, in a clean,
safe and usable condition. All spills of soil, rock or construction debris shall be
removed immediately.
Prior to Final
Map Approval
PWDR-3. The owner (applicant) shall provide Irrevocable Offers of
Dedication for all required easements and/or rights-of-way on the Final Map,
in substantial conformance with the approved Tentative Map, prior to Final
Map approval. Additional easements for storm water drainage and treatment
facilities shall be dedicated on the Final Map as needed.
At Final Map
Submittal
PWDR-4. The owner (applicant) shall submit engineered improvement plans
to the City Engineer in conformance with the approved Tentative Map and in
accordance with the design and improvement requirements of Chapter 14 of
the Municipal Code. The improvement plans shall be reviewed and approved
by the City Engineer and the appropriate officials from other public agencies
having jurisdictional authority, including public and private utility providers,
prior to approval of the Final Map. Improvement requirements shall include,
but not necessarily be limited to:
a.Replace existing asphalt swale with new concrete swale.
b.Install a new conforming driveway approach that meets the width
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 19
requirements in City Standard Details 205 and 206 and meets the quantity and
spacing requirements set forth in Section 14-25.030(r) of the Municipal Code.
Prior to Final
Map Approval
PWDR-5. The owner (applicant) shall pay the Subdivision Improvement Plan
Checking and Inspection fees, determined by the current Saratoga Fee
Schedule, at the time Improvement Plans are submitted for review.
Prior to Final
Map Approval
PWDR-6. The owner (applicant) shall enter into a Subdivision Improvement
Agreement with the City in accordance with Section 14-60.010 of the
Municipal Code prior to Final Map approval.
Prior to Final
Map Approval
PWDR-7. The owner (applicant) shall furnish security in accordance with
Section 14-60.020 of the Municipal Code prior to Final Map approval.
Prior to Final
Map Approval
PWDR-8. The owner (applicant) shall furnish proof of insurance coverage, in
accordance with Section 14-05.055 of the Municipal Code, prior to Final Map
approval.
Prior to Final
Map Approval
PWDR-9. The owner (applicant) shall pay the applicable Park Development
fee prior to Final Map approval.
Prior to Final
Map Approval
PWDR-10. The owner (applicant) shall secure all necessary permits from the
City and any other public agencies, including public and private utility
providers, prior to commencement of subdivision improvement construction.
Copies of permits other than those issued by the City shall be provided to the
City Engineer.
E. Fire Department
When
Required/Time
for Compliance
Condition of Approval
Prior to
commencement
of site work,
grading, or
construction.
FIRE-1. Fire Sprinklers Required: (As Noted on Sheet G000) Approved
automatic sprinkler systems in new and existing buildings and structures shall be
provided in the locations described in this Section or in Sections 903.2.1 through
903.2.12 whichever is the more restrictive and Sections 903.2.14 through
903.2.21. For the purposes of this section, firewalls and fire barriers used to
separate building areas shall be constructed in accordance with the California
Building Code and shall be without openings or penetrations.
Prior to
commencement
of site work,
grading, or
construction.
FIRE-2. Ground Ladder / Emergency Rescue Openings Required: (As Noted
on Sheet A300) Ground-ladder rescue from second and third floor rooms shall be
made possible for fire department operations. Climbing angle of seventy five
degrees shall be demonstrated on the plans and maintained. Landscaping shall not
be allowed to interfere with the required access (CFC Sec. 503 and 1031 NFPA
1932 Sec. 5.1.8 through 5.1.9.2).
Prior to
commencement
of site work,
grading, or
construction.
FIRE-3. Required Fire Flow: (Letter Received) The minimum require fireflow
for this project is 500 Gallons Per Minute (GPM) at 20 psi residual pressure. This
fireflow assumes installation of automatic fire sprinklers per CFC [903.3.1.3]
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 20
Prior to
commencement
of site work,
grading, or
construction.
FIRE-4. Water Supply Requirements: Potable water supplies shall be protected
from contamination caused by fire protection water supplies. It is the
responsibility of the applicant and any contractors and subcontractors to contact
the water purveyor supplying the site of such project, and to comply with the
requirements of that purveyor. Such requirements shall be incorporated into the
design of any water-based fire protection systems, and/or fire suppression water
supply systems or storage containers that may be physically connected in any
manner to an appliance capable of causing contamination of the potable water
supply of the purveyor of record. Final approval of the system(s) under
consideration will not be granted by this office until compliance with the
requirements of the water purveyor of record are documented by that purveyor as
having been met by the applicant(s). 2022 CFC Sec. 903.3.5 and Health and
Safety Code 13114.7.
Prior to
commencement
of site work,
grading, or
construction.
FIRE-5. Address identification: New and existing buildings shall have
approved address numbers, building numbers or approved building identification
placed in a position that is plainly legible and visible from the street or road
fronting the property. These numbers shall contrast with their background. Where
required by the fire code official, address numbers shall be provided in additional
approved locations to facilitate emergency response. Address numbers shall be
Arabic numbers or alphabetical letters. Numbers shall be a minimum of 6 inches
high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by
means of a private road and the building cannot be viewed from the public way, a
monument, pole or other sign or means shall be used to identify the structure.
Address numbers shall be maintained. CFC Sec. 505.1.
Prior to
commencement
of site work,
grading, or
construction.
FIRE-6. Construction Site Fire Safety: All construction sites must comply with
applicable provisions of the CFC Chapter 33 and our Standard Detail and
Specification S1-7. Provide appropriate notations on subsequent plan submittals,
as appropriate to the project. CFC Chp. 33.
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Resolution 26-058
Page 21
F. Surveyor
When
Required/Time
for Compliance
Condition of Approval
Prior to building
permit submittal
SUR 1 - Tract (Final) Map. The applicant shall submit a Tract Map and all
related requirements in a format acceptable to the City for recordation to the
satisfaction of the City Surveyor and approval by the City Engineer and pay all
related fees/deposits. The executed Tract (Final) Map shall be recorded prior to
building permit submittal.
Ongoing SUR 2 The development shall be located and constructed to include those
features, and only those features, as shown on the Tentative Subdivision Map.
A final map shall be prepared substantially in accord with the tentative map as
approved. Any substantial change to the tentative may require additional
review by the Planning Commission. All proposed changes to the Tentative
Subdivision Map must be submitted in writing with plans showing the
changes, including a clouded set of plans highlighting the changes.
At Final Map
Submittal
SUR 3 The owner (applicant) shall submit a Final Map in substantial
conformance with the approved Tentative Map, along with the additional
documents required by Section 14-40.020 of the Municipal Code, to the City
Engineer for examination. The Final Map shall contain all of the information
required in Section 14-40.030 of the Municipal Code and shall be
accompanied by the following items:
A. Two copies of map checking calculations.
B. Preliminary Title Report for the property dated within ninety (90) days
of the date of submittal for the Final Map.
C. Two copies of each map referenced on the Final Map.
D. Two copies of each document/deed referenced on the Final Map.
Two copies of any other map, document, deed, easement or other resource that
will facilitate the examination process as requested by the City Engineer
Prior to Final
Map approval
SUR 4 Interior monuments shall be set at each lot corner either prior to
recordation of the Final Map or some later date to be specified on the Final
Map. If the owner (applicant) chooses to defer the setting of interior
monuments to a specified later date, then sufficient security as determined by
the City Engineer shall be furnished prior to Final Map approval, to guarantee
the setting of interior monuments.
2121550.1
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Community Development
Department
13777 Fruitvale Avenue
Saratoga, CA 95070
www.saratoga.ca.us/171/trees
408.868.1276
CITY OF SARATOGA ARBORIST APPROVAL
Conditions of Approval and Tree Protection Plan
Prepared by Christina Fusco, City Arborist Application No.
Phone: (408) 868-1276 Address: 14486 Oak Place
Email: cfusco@saratoga.ca.us Owner: Deepak Chandani
APN: 397-22-005
Date: September 24, 2024
PROJECT SCOPE:
The applicant has submitted plans to demolish the existing home subdivide the lot and build three
townhomes. Two trees are requested for removal to construct the project.
PROJECT DATA IN BRIEF:
Tree security deposit – Required - $39,800
Tree protection – Required – See Conditions of Approval and attached map.
Tree removals – Trees #1 and 2 meet the criteria for removal and may be
removed once building division permits have been issued.
Replacement trees – Required = $11,530
ATTACHMENTS:
1 – Findings and Tree Information
2 – Tree Removal Criteria
3 – Conditions of Approval
4 – Map Showing Tree Protection
1 of 8
Resolution 26-058 Page 22Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
14486 Oak Place Attachment 1
FINDINGS:
Tree Removals
According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part
of a project, certain findings must be made and specific tree removal criteria met. Two
liquidambar trees are in conflict with the project, and meet the City’s criteria allowing them to be
removed and replaced as part of the project, once building division permits have been obtained.
Attachment 2 contains the tree removal criteria for reference.
Table 1: Summary of Tree Removal Criteria that are met
Tree No. Species Criteria met Comments
3 Liquidambar
Liquidambar styraciflua 6, 7, 9 In conflict with proposed
driveway
4 Liquidambar
Liquidambar styraciflua 6, 7, 9 In conflict with proposed
driveway
New Construction
Based on the information provided, and as conditioned, this project complies with the
requirements for the setback of new construction from existing trees under Section 15-50.120 of
the City Code.
Tree Preservation Plan
Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy
this requirement the following shall be copied onto a plan sheet and included in the final sets of
plans:
1)The tree information, recommendations, and the map showing tree protection from the
submitted arborist report dated September 12, 2024;
2)The Project Data in Brief and the Conditions of Approval from this report dated September 24,
2024.
TREE INFORMATION:
Project Arborist: Kailtyn Meyer
Date of Report: September 12, 2024
Number of protected trees inventoried: 4
Number of protected trees requested for removal: 2
A table summarizing information about each tree is below.
Table 2: Tree information from submitted arborist report dated September 12, 2024.
2 of 8
Resolution 26-058 Page 23Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
Ch
a
n
d
a
n
i
R
e
s
i
d
e
n
c
e
0
9
/
1
2
/
2
0
2
4
Nu
m
b
e
r
Co
m
m
o
n
N
a
m
e
Bo
t
a
n
i
c
a
l
N
a
m
e
DB
H
(i
n
c
h
e
s
)
m
a
t
h
.
DB
H
(i
n
c
h
e
s
)
He
i
g
h
t
(f
e
e
t
)
Sp
r
e
a
d
(f
e
e
t
)
Co
n
d
i
t
i
o
n
Ag
e
Sp
e
c
i
e
s
To
l
e
r
a
n
c
e
6X
D
S
H
*
(f
e
e
t
)
TP
Z
m
u
l
t
.
Fa
c
t
o
r
Id
e
a
l
T
P
Z
Ra
d
i
u
s
(
f
t
)
Im
p
a
c
t
Le
v
e
l
*
*
Su
i
t
a
b
i
l
i
t
y
Ra
t
i
n
g
Re
m
o
v
e
/
Pr
e
s
e
r
v
e
Ap
p
r
a
i
s
a
l
Re
s
u
l
t
1
Sw
e
e
t
g
u
m
Li
q
u
i
d
a
m
b
a
r
s
t
y
r
a
c
i
f
l
u
a
21
.
5
21
.
5
50
20
FA
I
R
MA
T
U
R
E
MO
D
E
R
A
T
E
11
12
22
SE
V
E
R
E
LO
W
RE
M
O
V
E
(
X
)
$7
,
1
0
0
2
Sw
e
e
t
g
u
m
Li
q
u
i
d
a
m
b
a
r
s
t
y
r
a
c
i
f
l
u
a
17
17
45
15
FA
I
R
MA
T
U
R
E
MO
D
E
R
A
T
E
9
12
17
SE
V
E
R
E
LO
W
RE
M
O
V
E
(
X
)
$4
,
4
3
0
3
Sw
e
e
t
g
u
m
Li
q
u
i
d
a
m
b
a
r
s
t
y
r
a
c
i
f
l
u
a
14
14
30
15
PO
O
R
MA
T
U
R
E
MO
D
E
R
A
T
E
7
12
14
MO
D
E
R
A
T
E
MO
D
E
R
A
T
E
PR
E
S
E
R
V
E
$1
,
5
0
0
4
Va
l
l
e
y
O
a
k
Qu
e
r
c
u
s
l
o
b
a
t
a
es
t
.
3
6
36
60
50
GO
O
D
MA
T
U
R
E
MO
D
E
R
A
T
E
18
12
36
MO
D
E
R
A
T
E
HI
G
H
PR
E
S
E
R
V
E
$3
8
,
3
0
0
KE
Y
:
TO
T
A
L
A
P
P
R
A
I
S
E
D
V
A
L
U
E
*
*
*
$5
1
,
3
3
0
#
Ne
i
g
h
b
o
r
i
n
g
/
C
i
t
y
S
t
r
e
e
t
T
r
e
e
VA
L
U
E
O
F
T
R
E
E
S
T
O
R
E
M
A
I
N
$3
9
,
8
0
0
Re
m
o
v
a
l
R
e
q
u
e
s
t
RE
P
L
A
C
E
M
E
N
T
V
A
L
U
E
$1
1
,
5
3
0
SE
C
U
R
I
T
Y
D
E
P
O
S
I
T
(
1
0
0
%
)
$3
9
,
8
0
0
SE
E
G
L
O
S
S
A
R
Y
F
O
R
D
E
F
I
N
I
T
I
O
N
O
F
T
E
R
M
S
TR
E
E
I
N
V
E
N
T
O
R
Y
-
1
4
4
8
6
O
a
k
P
l
a
c
e
,
S
a
r
a
t
o
g
a
,
C
A
pg
.
1
9
TR
E
E
I
M
P
A
C
T
A
S
S
E
S
S
M
E
N
T
*
6
X
D
S
H
i
s
t
h
e
d
i
s
t
a
n
c
e
f
r
o
m
t
r
u
n
k
f
a
c
e
t
o
t
r
a
n
s
v
e
r
s
e
r
o
o
t
c
u
t
(
i
.
e
.
t
r
e
n
c
h
i
n
g
p
a
s
t
a
t
r
e
e
)
,
t
h
a
t
re
s
u
l
t
s
i
n
a
p
p
r
o
x
i
m
a
t
e
l
y
2
5
%
r
o
o
t
l
o
s
s
.
M
o
r
e
t
h
a
n
2
5
%
r
o
o
t
l
o
s
s
i
s
l
i
k
e
l
y
t
o
r
e
s
u
l
t
i
n
t
h
e
d
e
c
l
i
n
e
an
d
/
o
r
i
n
s
t
a
b
i
l
t
y
o
f
a
t
r
e
e
.
T
h
e
C
i
t
y
A
r
b
o
r
i
s
t
c
o
m
m
o
n
l
y
u
s
e
s
t
h
i
s
n
u
m
b
e
r
a
s
t
h
e
s
e
t
b
a
c
k
t
h
e
y
re
q
u
i
r
e
f
r
o
m
e
x
c
a
v
a
t
i
o
n
w
o
r
k
t
o
a
t
r
e
e
t
o
b
e
p
r
e
s
e
r
v
e
d
.
**
A
S
S
U
M
E
S
S
T
A
N
D
A
R
D
A
N
D
S
P
E
C
I
A
L
T
R
E
E
P
R
O
T
E
C
T
I
O
N
M
E
A
S
U
R
E
S
A
R
E
F
O
L
L
O
W
E
D
.
**
*
I
d
i
d
n
o
t
i
n
c
l
u
d
e
t
r
e
e
s
i
n
t
h
e
p
a
t
h
o
f
i
n
g
r
e
s
s
a
n
d
e
g
r
e
s
s
(
m
a
r
k
e
d
a
s
"
v
e
r
y
l
o
w
"
)
i
n
t
h
e
ap
p
r
a
i
s
a
l
t
o
t
a
l
,
b
a
s
e
d
o
n
g
u
i
d
a
n
c
e
f
r
o
m
t
h
e
C
i
t
y
A
r
b
o
r
i
s
t
t
h
a
t
t
h
e
s
e
t
y
p
i
c
a
l
l
y
d
o
n
o
t
c
o
u
n
t
to
w
a
r
d
s
t
h
e
d
e
p
o
s
i
t
.
Pr
e
p
a
r
e
d
b
y
B
u
s
a
r
a
F
i
r
e
s
t
o
n
e
IS
A
C
e
r
t
i
f
i
e
d
A
r
b
o
r
i
s
t
#
W
E
-
8
5
2
5
A
3
o
f
8
14
4
8
6
Oa
k
P
la
c
e
At
t
a
c
h
m
e
n
t
1
Resolution 26-058 Page 24Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
14486 Oak Place Attachment 2
TREE REMOVAL CRITERIA
Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-
50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are
made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during
construction.
(1)The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or
proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen
tree.
(2)The necessity to remove the tree because of physical damage or threatened damage to improvements or
impervious surfaces on the property.
(3)The topography of the land and the effect of the tree removal upon erosion, soil retention and the
diversion or increased flow of surface waters, particularly on steep slopes.
(4)The number, species, size and location of existing trees in the area and the effect the removal would have
upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of
residents in the area.
(5)The age and number of healthy trees the property is able to support according to good forestry practices.
(6)Whether or not there are any alternatives that would allow for retaining or not encroaching on the
protected tree.
(7)Whether the approval of the request would be contrary to or in conflict with the general purpose and
intent of this Article.
(8)Any other information relevant to the public health, safety, or general welfare and the purposes of this
ordinance as set forth in Section 15-50.010
(9)The necessity to remove the tree for economic or other enjoyment of the property when there is no other
feasible alternative to the removal.
(10)The necessity to remove the tree for installation and efficient operation of solar panels, subject to the
requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed
and replacement trees planted in conformance with the City Arborist's recommendation.
(11)The necessity to remove a tree following the creation of defensible space within 100 feet of a structure
located within the Wildland Urban Interface, in accordance with defensible space standards established
by CAL FIRE or as determined by Santa Clara County Fire Department, and that risk of increased wildfire
cannot reasonably be addressed through maintenance or without tree removal.
(12)Monterey pine (Pinus radiata) or blue gum (Eucalyptus globulus) located within the Wildland Urban
Interface Area as defined in section 16-20.150 of this Code.
4 of 8
Resolution 26-058 Page 25Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
14486 Oak Place Attachment 3
CONDITIONS OF APPROVAL
1)Owner, Architect, Contractor: It is the responsibility of the owner, architect, and contractor to
be familiar with the information in this report and implement the required conditions.
2)Permit:
a)Receipt of a Planning or Building permit does not relieve the applicant of their
responsibilities for protecting trees per City Code Article 15-50 on all construction
work.
b)No protected tree authorized for removal or encroachment pursuant to this project
may be removed or encroached upon until the issuance of the applicable permit from
the building division for the approved project.
3)Final Plan Sets:
a)Shall include the tree information, protection recommendations, and map showing
tree protection from the arborist report by Kailtyn Meyer dated September 12, 2024
copied onto a plan sheet.
b)Shall include the Project Data in Brief and Conditions of Approval sections of the City
Arborist report dated September 24, 2024.
4)Tree Protection Security Deposit:
a)Is required per City Ordinance 15-50.080.
b)Shall be $39,800 for trees #3 and 4.
c)Shall be obtained by the owner and filed with the Community Development
Department before obtaining Building Division permits.
d)May be in the form of cash, check, or a bond.
e)Shall remain in place for the duration of construction of the project.
f)May be released once the project has been completed, inspected and approved by the
City Arborist.
5)Tree Protection Fencing:
a)Shall be installed as shown on the attached map.
b)Shall be shown on the Site Plan.
c)Shall be established prior to the arrival of construction equipment or materials on site.
d)Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter
galvanized posts, driven into the ground and spaced no more than 10 feet apart.
e)Shall be posted with signs saying, “TREE PROTECTION FENCE - DO NOT MOVE OR
REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, CHRISTINA FUSCO (408) 868-
1276”.
f)A letter/email shall be provided to the City from the project arborist confirming the
correct installation of the tree protection fencing once it has been installed, including
photos. This is required prior to obtaining building division permits.
g)Tree protection fencing shall remain undisturbed throughout the construction until
final inspection.
5 of 8
Resolution 26-058 Page 26Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
14486 Oak Place Attachment 3
6)Construction: All construction activities shall be conducted outside tree protection fencing
unless permitted as conditioned below. These activities include, but are not necessarily
limited to, the following: demolition, grading, trenching for utility installation, equipment
cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle
operation and parking.
7)Work inside fenced areas:
a)Requires a field meeting and approval from City Arborist before performing work.
b)Requires Project Arborist on site to monitor work.
8)Project Arborist:
a)Shall be Kailtyn Meyer unless otherwise approved by the City Arborist.
b)Shall visit the site every two weeks during grading, trenching or digging activities and
every six weeks thereafter. A letter/email shall be provided to the City after each
inspection which documents the work performed around trees, includes photos of the
work in progress, and provides information on tree condition during construction.
c)Shall supervise any permitted pruning or root pruning of trees on site. Roots of
protected trees measuring two inches in diameter or more shall not be cut without
prior approval of the Project Arborist.
d)The Project Arborist shall be on site to monitor all work within 20 feet of tree #4.
e)The recommendations from the submitted arborist report dated September 12, 2024
are conditions of approval for the project.
9)Tree removal: Trees #1 and 2 meet the criteria for removal and may be removed once building
division permits have been obtained.
10)New trees:
a)New trees equal to $11,530 shall be planted as part of the project before final
inspection and occupancy of the new home. New trees may be of any species and
planted anywhere on the property as long as they do not encroach on retained trees.
Replacement values for new trees are listed below.
15 gallon = $350 24 inch box = $500 36 inch box = $1,500
48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000
b)Trees shall be replaced on or off site according to good forestry practices and shall
provide equivalent value in terms of aesthetic and environmental quality, size, height,
location, appearance, and other significant beneficial characteristics of the removed
trees.
11)Damage to protected trees that will be retained: Should any protected tree be damaged
beyond repair:
a)New trees shall be required to replace the tree(s) equal to the assessed value of the
damaged/removed tree(s). Replacement values for new trees are listed above.
6 of 8
Resolution 26-058 Page 27Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
14486 Oak Place Attachment 3
b)A payment shall be made to the City Tree Fund equal to the assessed value of the
damaged/removed trees.
c)These remedies are cumulative and not exclusive.
12)Final inspection: At the end of the project, when the contractor wants to remove tree
protection fencing and have the tree protection security deposit released by the city, call City
Arborist for a final inspection. Before scheduling a final inspection from the City Arborist, have
the project arborist do an inspection, prepare a letter with their findings, and provide that
letter to the city for the project file.
7 of 8
Resolution 26-058 Page 28Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
DA
T
E
:
09
/
1
2
/
2
4
TP
Z
E
L
E
M
E
N
T
S
D
R
A
W
N
:
K.
M
E
Y
E
R
IS
A
-
C
E
R
T
I
F
I
E
D
A
R
B
O
R
I
S
T
#W
E
-
1
4
9
9
2
A
BA
S
E
M
A
P
:
S
I
T
E
P
L
A
N
T
P
M
-
4
by
S
T
E
R
L
I
N
G
C
O
N
S
U
L
T
A
N
T
S
(0
9
/
0
2
/
2
0
2
4
)
AR
B
O
R
I
S
T
R
E
P
O
R
T
pg
.
2
0
TREE PROTECTION ZONE MAP
14486 OAK PLACE, SARATOGA, CA
NP
(
7
”
C
I
T
R
U
S
)
TP
Z
M
A
P
L
E
G
E
N
D
:
NE
I
G
H
B
O
R
I
N
G
/
C
I
T
Y
S
T
R
E
E
T
T
R
E
E
TR
E
E
P
R
O
T
E
C
T
I
O
N
F
E
N
C
I
N
G
(
S
E
E
S
P
E
C
.
)
NP
-
“
N
O
T
P
R
O
T
E
C
T
E
D
”
B
Y
C
I
T
Y
C
O
D
E
n
PR
O
T
E
C
T
E
D
T
R
E
E
T
O
R
E
M
O
V
E
n
1
4
.
TP
Z
N
O
T
E
:
E
R
E
C
T
T
P
Z
F
E
N
C
I
N
G
PR
O
M
P
T
L
Y
A
F
T
E
R
D
E
O
M
L
I
T
I
O
N
O
F
EX
I
S
T
I
N
G
G
A
R
A
G
E
,
W
H
I
C
H
W
A
S
I
N
DI
R
E
C
T
C
O
N
T
A
C
T
W
I
T
H
T
R
E
E
#
4
.
Tr
e
e
p
r
o
t
e
c
t
i
o
n
f
e
n
c
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
a
s
r
e
q
u
i
r
e
d
b
y
t
h
e
C
i
t
y
o
f
S
a
r
a
t
o
g
a
:
1.
Si
x
-
f
o
o
t
h
i
g
h
c
h
a
i
n
l
i
n
k
f
e
n
c
i
n
g
m
o
u
n
t
e
d
o
n
e
i
g
h
t
-
f
o
o
t
t
a
l
l
,
2
-
i
n
c
h
d
i
a
m
e
t
e
r
g
a
l
v
a
n
i
z
e
d
p
o
s
t
s
,
d
r
i
v
e
n
24
i
n
c
h
e
s
i
n
t
o
t
h
e
g
r
o
u
n
d
a
n
d
s
p
a
c
e
d
n
o
m
o
r
e
t
h
a
n
1
0
f
e
e
t
a
p
a
r
t
.
2.
Fe
n
c
e
s
m
u
s
t
b
e
p
o
s
t
e
d
w
i
t
h
s
i
g
n
s
s
a
y
i
n
g
:
“T
R
E
E
P
R
O
T
E
C
T
I
O
N
F
E
N
C
E
–
D
O
N
O
T
M
O
V
E
O
R
R
E
M
O
V
E
W
I
T
H
O
U
T
A
P
P
R
O
V
A
L
F
R
O
M
CI
T
Y
A
R
B
O
R
I
S
T
,
C
H
R
I
S
T
I
N
A
F
U
S
C
O
–
4
0
8
8
6
8
-
1
2
7
6
.
”
3.
Th
e
C
i
t
y
r
e
q
u
i
r
e
s
t
h
a
t
t
r
e
e
p
r
ot
e
c
t
i
o
n
f
e
n
c
i
n
g
b
e
i
n
s
t
a
l
l
e
d
b
e
f
o
r
e
a
n
y
e
q
u
i
p
m
e
n
t
c
o
m
e
s
o
n
s
i
t
e
an
d
i
n
s
p
e
c
t
e
d
b
y
t
h
e
C
i
t
y
A
r
b
o
r
i
s
t
b
e
f
o
r
e
i
s
s
u
a
n
c
e
o
f
p
e
r
m
i
t
s
.
4.
Tr
e
e
p
r
o
t
e
c
t
i
o
n
f
e
n
c
i
n
g
i
s
r
e
q
u
i
r
e
d
t
o
r
e
m
a
i
n
i
n
p
l
a
c
e
t
h
r
o
u
g
h
o
u
t
c
o
n
s
t
r
u
c
t
i
o
n
.
5.
Th
e
T
R
E
E
P
R
O
T
E
C
T
I
O
N
Z
O
N
E
i
s
t
h
e
d
i
s
t
a
n
c
e
f
r
o
m
t
h
e
t
r
u
n
k
t
o
a
p
o
i
n
t
t
h
a
t
i
s
f
i
v
e
f
e
e
t
b
e
-
yo
n
d
t
h
e
c
a
n
o
p
y
o
f
a
t
r
e
e
p
r
o
t
e
c
t
e
d
b
y
C
i
t
y
c
o
d
e
.
T
r
e
e
p
r
o
t
e
c
t
i
o
n
f
e
n
c
i
n
g
s
h
a
l
l
b
e
l
o
c
a
t
e
d
a
s
c
l
o
s
e
t
o
th
i
s
l
o
c
a
t
i
o
n
a
s
p
o
s
s
i
b
l
e
w
h
i
l
e
s
t
i
l
l
a
l
l
o
w
i
n
g
r
o
o
m
f
o
r
c
o
n
s
t
r
u
c
t
i
o
n
t
o
o
c
c
u
r
.
2
3
8
o
f
8
At
t
a
c
h
m
e
n
t
4
Resolution 26-058 Page 29
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
-Page 1 of 3-
Saratoga Indemnity Agreement
AGREEMENT TO HOLD HARMLESS, INDEMNIFY, AND DEFEND THE
CITY OF SARATOGA
This agreement pertains to the project located at 14486 Oak Place in the City of Saratoga (the
“Property”) pursuant to CPX24-0011/ ENV25-0018 and such subsequent requests for approvals
as may be submitted by the undersigned or its agents (e.g., building, grading, and other permits or
clearances). These applications and requests for approval are referred to below as the “Approvals.”
All references to “City” mean the City of Saratoga which includes, but is not limited to, the City
as a municipal corporation, its City Council, officers, boards, commissions, employees, agents,
volunteers and consultants.
In consideration of the fulfillment of a condition of the Approvals, the sufficiency of which is
hereby acknowledged, the undersigned hereby:
1. Agrees to defend, indemnify and hold harmless City from and against any and all claims,
cross-claims, demands, actions, suits, proceedings, expenses, damages, or liabilities arising
out of, or in any manner related to, actions taken in processing or acting on the Approvals
or from performance of work authorized by the Approvals.
2.Agrees that if defense of the City is required, the City shall have the right to approve the
choice of defense counsel, which approval shall not be unreasonably withheld or delayed.
If City and the undersigned are unable to agree on counsel within ten (10) days of a written
request for defense, City may select counsel of its choice and the undersigned shall be
responsible for all reasonable fees and costs. In the event that City and the undersigned
have conflicting interests in the proceedings, City and the undersigned shall each retain
separate, independent counsel at the undersigned’s expense. If a defense is requested by
City, such defense shall include all stages of litigation, including, but not limited to, any
and all appeals or petitions related to lower court judgments or appellate decisions.
3.Agrees that the indemnification obligations arising from this agreement include, but are
not limited to, damages, costs, expenses, attorneys’ fees and expert witness costs incurred
by the City, as well as damages, costs, expenses (including, but not limited to, preparation
and certification of an administrative record to the extent not paid for, or recovered as costs,
by the challenging party), attorneys’ fees (including, but not limited to, private attorney
general fees recovered by a challenging party) or expert witness costs claimed by, or
awarded to, any person or entity, including the undersigned, against the City. To the extent
that the City is required to use any of its own resources to respond to any claim, cross-
claim, action, suit or proceeding, the undersigned shall reimburse the City upon demand
and upon presentation of an invoice describing the work done, the time spent on such work,
and the hourly rate for such work by the employee, consultant, or agent of the City,
including, but not limited to, all costs and fees incurred in additional investigation or study.
The hourly rates charged shall not exceed the rates set forth in City’s then-current adopted
fee schedule, or, for tasks not performed by City staff, the actual cost billed to the City.
Resolution 26-058 Page 30
Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
-Page 2 of 3-
4.Agrees that this agreement shall survive the expiration, termination, withdrawal, or
revocation of any Approval, the completion of all construction, and the sale or transfer of
the Property.
5. Agrees to the following general matters.
A.This instrument sets forth the entire agreement of the parties with respect to this
agreement for indemnification required by the Saratoga City Code, and supersedes
all prior understandings, discussions, negotiations, or agreements relating to the
Agreement, all of which are merged herein. No alteration or variation of this
instrument shall be valid or binding unless the undersigned and City jointly amend
this agreement in writing. In the event of any inconsistency between this
Agreement and any Approval this Agreement shall prevail.
B.This Agreement shall be construed and interpreted in accordance with the laws of
the State of California. In any action initiated to enforce the terms hereof or declare
rights hereunder, venue thereof shall be the County of Santa Clara, State of
California.
C.The undersigned acknowledges its right to obtain independent legal advice prior to
entering into this Agreement. The undersigned has either obtained the advice of
legal counsel prior to entering this Agreement or voluntarily waives the right to do
so by signing it.
6.Agrees that if the person or entity submitting an application for any of the Approvals (an
“Applicant”) is different from the owner of the Property then this Agreement shall be
signed by the owner of the property and each Applicant and each signatory shall be jointly
and severally liable for all obligations hereunder.
Accepted and agreed.
OWNER
Signature:
_____________________________________
Signature:
_____________________________________
Printed Name:
_____________________________________
Printed Name:
_____________________________________
Title (if entity):
_____________________________________
Title (if entity):
___________________________________
Address for Notices:
Resolution 26-058 Page 31Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7
-Page 3 of 3-
APPLICANT
Signature:
_____________________________________
Signature:
_____________________________________
Printed Name:
_____________________________________
Printed Name:
_____________________________________
Title (if entity):
_____________________________________
Title (if entity):
___________________________________
Address for Notices:
2076158.3
Resolution 26-058 Page 32Docusign Envelope ID: 4646D25F-5F02-8E58-81C9-C1D5BB3D31C7