Loading...
HomeMy WebLinkAbout02092022 Planning Commission Meeting PacketSaratoga Planning Commission Agenda – Page 1 of 4 SARATOGA PLANNING COMMISSION REGULAR MEETING FEBRUARY 9, 2022 7:00 P.M. - PLANNING COMMISSION REGULAR MEETING This meeting will be entirely by teleconference and will be conducted in compliance with Government Code section 54953(e) of the Ralph M. Brown Act allowing teleconferencing during a proclaimed state of emergency when state or local officials have imposed or recommended measures to promote social distancing. The public will not be able to participate in the meeting in person. During the meeting the Chair will explain the process for members of the public to be recognized to offer public comment. Members of the public view and participate in the meeting by: 1. Using the Zoom website https://us02web.zoom.us/j/82652375945 App (Webinar ID 826 5237 5945) and using the tool to raise their hand in the Zoom platform when directed by the Chair to speak on an agenda item; OR 2. Calling 1.669.900.6833 or 1.408.638.0968 and pressing *9 to raise their hand to speak on an agenda item when directed by the Chair; OR 3. Viewing the meeting on Saratoga Community Access Television Channel 15 (Comcast Channel 15, AT&T UVerse Channel 99) and calling 1.669.900.6833 or 1.408.638.0968 and pressing *9 to raise their hand to speak on an agenda item when directed by the Chair; OR 4. Viewing online at http://saratoga.granicus.com/MediaPlayer.php?publish_id=2 and calling 1.669.900.6833 or 1.408.638.0968 and pressing *9 to raise their hand to speak on an agenda item when directed by the Chair. Members of the public can send written comments to the Commission prior to the meeting by commenting online at www.saratoga.ca.us/pc prior to the start of the meeting. These emails will be provided to the members of the Commission and will become part of the official record of the meeting. ROLL CALL APPROVAL OF MINUTES Action Minutes from the Planning Commission Meeting of January 12, 2022. Recommended Action: Approve Minutes of January 12, 2022 Planning Commission Meeting. ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS Any member of the public will be allowed to address the Planning Commission for up to three (3) minutes on matters not on this agenda. This law generally prohibits the Planning Commission from discussing or taking action on such items. However, the Planning Commission may instruct staff accordingly regarding Oral Communications. Saratoga Planning Commission Agenda – Page 2 of 4 REPORT ON APPEAL RIGHTS If you wish to appeal any decision on this Agenda, you may file an Appeal Application with the City Clerk within fifteen (15) calendar days of the date of the decision. 1. NEW BUSINESS 2. PUBLIC HEARING Applicants and/or their representatives have a total of ten (10) minutes maximum for opening statements. All interested persons may appear and be heard during this meeting regarding the items on this agenda. If items on this agenda are challenged in court, members of the public may be limited to raising only issues raised at the Public Hearing or in written correspondence delivered to the Planning Commission at, or prior to the close of the Public Hearing. Members of the public may comment on any item for up to three (3) minutes. Applicants and/or their representatives have a total of five (5) minutes maximum for closing statements. 2.1 (Continued from December 8, 2021) Application PDR21-0015/ARB21-0082; 12470 Paseo Cerro (386-46-015); Anat Shmariahu (Applicant) – The applicant is requesting Design Review approval for an addition to an existing 1,584 square foot one-story single-family residence. The project will include a 1,197 square foot first floor addition and a 239 square foot second story addition for a total project square footage of 3,379 square feet. No protected trees are proposed for removal. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-007 approving the application for Design Review as staff is able to make all the required design review findings to recommend approval. 2.2 (Continued from January 12, 2022) - Application PDR21-0008/ARB21-0034; 13514 Hammons Avenue (393-34-009; Tom Sloan, AIA (Applicant) – The applicant is requesting Design Review approval for a project which would include removal of an existing 3,972 square foot one story single-family residence and the construction of a new 4,206 square foot one story single-family residence with an overall height of 23’-9”. Two protected trees are proposed for removal which include an apple tree and a Japanese maple. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-001 approving the project subject to conditions of approval included in Attachment 1. 2.3 Application PDR21-0018/ARB21-0067; 14780 Montalvo Road (517-20-033); Fan Yang and Zhifen Xu (Applicant) – The applicant is requesting Design Review approval for a 223 square foot single story addition and a 1,404 square foot second story addition (maximum height 26’) which includes an ADU, to an existing single-story residence. Two protected trees are proposed for removal. The site is zoned R-1-20,000 with a General Plan Designation of Residential Low Density (RLD). Staff Contact: Nicole Johnson (408) 868- 1209 or njohnson@saratoga.ca.us. Saratoga Planning Commission Agenda – Page 3 of 4 Recommended Action: Adopt Resolution No. 22-004 approving the project subject to conditions of approval included in Attachment 1. 2.4 Application PDR21-0020; 13251 Quito Road (389-18-049); Jawwad Sultan Khan (Applicant) – The applicant is requesting Design Review approval for a new 3,370 square foot one-story single-family residence with an attached 800 square foot accessory dwelling unit. The total square footage of the project will be 4,170 square feet and the height will be 22’-3”. No protected trees are proposed for removal. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-006 approving the project subject to conditions of approval included in Attachment 1. 2.5 Application PDR21-0016/ARB21-0069; 19701 Via Grande (393-19-019); Rajesh Chaganti and Sirisha Uppaluri Sirisha (Applicant) – The applicant is requesting Design Review approval for a new 4,707.8 square foot two story residence with an ADU (maximum height 25’6”). Six protected trees are proposed for removal. The site is zoned R-1-12,500 with a General Plan Designation of Medium Density Residential Low Density (M-12.5). Staff Contact: Nicole Johnson (408) 868-1209 or njohnson@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-005 approving the project subject to conditions of approval included in Attachment 1. 3. DIRECTOR ITEMS 4. COMMISSION ITEMS 5. ADJOURNMENT CERTIFICATE OF POSTING OF THE AGENDA, DISTRIBUTION OF THE AGENDA PACKET, COMPLIANCE WITH AMERICANS WITH DISABILITIES ACT I, Frances Reed, Administrative Analyst for the City of Saratoga, declare that the foregoing agenda for the meeting of the Planning Commission was posted and available for review on February 3, 2022 at the City of Saratoga, 13777 Fruitvale Avenue, Saratoga, California and on the City's website at www.saratoga.ca.us. Signed this 3rd day of February 2022 at Saratoga, California. Frances Reed, Administrative Analyst. In accordance with the Ralph M. Brown Act, copies of the staff reports and other materials provided to the Planning Commission by City staff in connection with this agenda, copies of materials distributed to the Planning Commission concurrently with the posting of the agenda, and materials distributed to the Planning Commission by staff after the posting of the agenda are available on the City Website at www.saratoga.ca.us or available at 13777 Fruitvale Avenue, Saratoga, CA 95070. In Compliance with the Americans with Disabilities Act, if you need assistance to participate in this meeting, please contact the City Clerk at bavrit@saratoga.ca.us or calling 408.868.1216 as Saratoga Planning Commission Agenda – Page 4 of 4 soon as possible before the meeting. The City will use its best efforts to provide reasonable accommodations to provide as much accessibility as possible while also maintaining public safety. [28 CFR 35.102-35.104 ADA title II] Saratoga Planning Commission Draft Minutes – Page 1 of 3 DRAFT MINUTES WEDNESDAY JANUARY 12, 2021 SARATOGA PLANNING COMMISSION REGULAR MEETING Vice Chair Zheng called the virtual Regular Meeting to order at 7:00 p.m. via teleconferencing through Zoom. Prior to Roll Call, the Vice Chair and Community Development Director explained that the Planning Commission meeting was conducted pursuant to Government Code section 54953(e) of the Ralph M. Brown Act allowing teleconferencing during a proclaimed state of emergency when state or local officials have imposed or recommended measures to promote social distancing. The Planning Commission met all the applicable notice requirements and the public is welcome to participate in this meeting. Information on how the public can observe the meeting and provide public comment was also shared. Additionally, the Chair explained that votes would be taken through roll call. ROLL CALL PRESENT: Vice Chair Herman Zheng, Commissioners Clinton Brownley, Jojo Choi and Razi Mohiuddin ABSENT: Chair Anjali Kausar, Commissioner Sunil Ahuja ALSO PRESENT: Debbie Pedro, Community Development Director Christopher Riordan, Senior Planner APPROVAL OF MINUTES Action Minutes from the Regular Planning Commission Meeting of December 8, 2021. Recommended Action: Approve Minutes of Regular Planning Commission Meeting of December 8, 2021. CHOI/BROWNLEY MOVED TO APPROVE THE MINUTES OF THE DECEMBER 8, 2021 MEETING. MOTION PASSED. AYES: BROWNLEY, CHOI, MOHIUDDIN, ZHENG. NOES: NONE. ABSENT: AHUJA, KAUSAR. ABSTAIN: NONE. ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS: NONE REPORT ON APPEAL RIGHTS 1. NEW BUSINESS - NONE 2. PUBLIC HEARING 2.1 Application PDR21-0014; 20896 Fourth Street (503-26-004); Jason Mundy (Applicant) – The applicant is requesting Design Review approval to remodel an existing 2,442 square foot one story single-family residence. The project would include remodeling the first floor for a total square footage of 2,804 square feet and the addition of a new 553 square foot second story for a total project square footage of 3,358 square feet. No protected trees are proposed for removal. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. 5 Saratoga Planning Commission Draft Minutes – Page 2 of 3 Recommended Action: Adopt Resolution No. 22-003 approving the project subject to conditions of approval included in Attachment 1. MOHIUDDIN/BROWNLEY MOVED TO APPROVE RESOLUTION NO. 22-003. MOTION PASSED. AYES: BROWNLEY, CHOI, MOHIUDDIN, ZHENG. NOES: NONE. ABSENT: AHUJA, KAUSAR. ABSTAIN: NONE. 2.2 Application PDR21-0008/ARB21-0034; 13514 Hammons Avenue (393-34-009; Tom Sloan, AIA (Applicant) – The applicant is requesting Design Review approval for a project which would include removal of an existing 3,972 square foot one story single- family residence and the construction of a new 4,206 square foot one story single-family residence with an overall height of 25’-10”. Two protected trees are proposed for removal which include an apple tree and a Japanese maple. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-001 approving the project subject to conditions of approval included in Attachment 1. MOHIUDDIN/ZHENG MOVED TO CONTINUE THE ITEM TO FEBRUARY 9, 2022 TO PROVIDE THE APPLICANT THE OPPORTUNITY TO MAKE MODIFICATIONS TO THE DESIGN. MOTION PASSED. AYES: BROWNLEY, CHOI, MOHIUDDIN, ZHENG. NOES: NONE. ABSENT: AHUJA, KAUSAR. ABSTAIN: NONE. 2.3 Application PDR21-0033; 12531 Paseo Cerro (386-11-031; Thanh Truong (Applicant) – The applicant is requesting Planning Commission Design Review approval to modify a previously approved Administrative Design Review application (ADR19-0011) to construct a new 3,162 square foot one story single-family residence with an overall height of 17’-11”. The proposed modifications would increase the overall height of the residence to 22’-11”. The project also includes the conversion of an existing 375 square feet nonconforming detached garage to an accessory dwelling unit without an increase in the nonconformity of the structure. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-002 approving the project subject to conditions of approval included in Attachment 1. MOHIUDDIN/CHOI MOVED TO APPROVE RESOLUTION NO. 22-002 WITH ADDITIONAL CONDITIONS AS DETAILED IN THE RESOLUTION ATTACHMENT. MOTION PASSED. AYES: BROWNLEY, CHOI, MOHIUDDIN, ZHENG. NOES: NONE. ABSENT: AHUJA, KAUSAR. ABSTAIN: NONE. 3. DIRECTOR ITEMS Director Pedro reported that City Council held a special meeting on January 10, 2022 to discuss the Planning Commissions’ recommendation for the Housing Element during which, 6 Saratoga Planning Commission Draft Minutes – Page 3 of 3 they did not make decisions on site opportunities but did approve many of the policy recommendations. Council will continue the discussion on January 19, 2022. 4. COMMISSION ITEMS Commissioner Mohiuddin asked staff to evaluate the plan-check process and identify ways to help lessen chances for errors such as a checklist. 5. ADJOURNMENT CHOI/ZHENG Moved to adjourn the meeting at 9:35 PM. Minutes respectfully submitted: Frances Reed, Administrative Analyst City of Saratoga 7 REPORT TO THE PLANNING COMMISSION 12470 Paseo Cerro Meeting Date: February 9, 2022 Application: PDR21-0015/ARB21-0082 Address/APN: 12470 Paseo Cerro / 386-46-015 Applicant / Property Owner: Anat Shmariahu / Sunitha & Stephen Ayers From: Debbie Pedro, Community Development Director Report Prepared By: Christopher Riordan, Senior Planner 8 Report to the Planning Commission 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a 1,555 square foot single story addition and a 239 square foot second story addition to an existing 1,584 square foot one-story single-family residence with a total project height of 21.63 feet. No protected trees are proposed for removal. STAFF RECOMMENDATION Adopt Resolution No. 22-007 approving the application for Design Review as staff is able to make all the required design review findings to recommend approval. Pursuant to City Code Section 15-45.060(a)(2), Design Review approval by the Planning Commission is required as the project is a conversion of a single-story structure to a multi-story structure. PROJECT DATA Gross/Net Site Area: 11,281 sq. ft. gross/net (.26 acres) Average Site Slope: Level Site General Plan Designation: M-10 (Medium Density Residential) Zoning: R-1-10,000 (Single Family Residential) Proposed Allowed/Required Site Coverage Residence Driveway Concrete Paving Total Proposed 3,544 sq. ft. 421 sq. ft. 1,430 sq. ft. 5,395 sq. ft. (47%) 6,768.6 sq. ft. (60 %) Floor Area First Story Area > 15’ in height Second Story Garage Total Floor Area 2,525.41 sq. ft. 256.7 sq. ft. 239.01 sq. ft. 358.80 sq. ft. 3,379.92 sq. ft. 3,540 sq. ft. Height 21.63’ 26’ Setbacks Front: Left Side: Right Side Rear First Floor 25.33’ 9.53’* 9.91’* 52.50’ Second Floor 56.08’ 35.62’ 35.90’ 63.17’ First Floor 25’ 10’ 10’ 25’ Second Floor 25’ 15’ 15’ 35’ Grading No Grading Proposed No grading limit in the R-1-10,000 zoning district * Existing nonconforming setbacks 9 Report to the Planning Commission 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 3 SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The project site is located at 12470 Paseo Cerro in the R-1-10,000 (Single Family Residential) zoning district. The 11,281 square foot site is relatively level with less than a one-foot change in elevation from the rear of the site to the front. Surrounding uses on all sides include one-story single-family homes on similar sized parcels. Existing structures on site include a one-story single-family residence with an attached garage. Two protected trees are located on site and include a 52” coast redwood and a 36 Douglas fir. Background The Planning Commission previously reviewed the project at their meeting of December 8, 2021. After receiving public testimony from the applicant, the Commission discussed the project and expressed concern that the height and mass of the project were inconsistent with the Design Review Findings. The Commission continued the project to a date uncertain to provide an opportunity for the applicant to make modifications to the design and return to the Commission with revised plans. To respond to the Commission’s concerns, the applicant submitted revised plans which included a modification to the pitch of the roof which reduced the height of the residence from 23’-10.5” to 21’-7.5”, for a total height reduction of 2’-1.5”. Additional modifications included adding a horizontal glass panel to the front elevation to help break up the mass of the flat surface and proposing one color (Boston white) for the color of the exterior stucco. Project Description The architectural style of the project can best be described as “modern”. The project will include both a 1,555 square foot single story addition and a 239 square foot addition for a total floor area of 3,379 square feet. The front and side elevations will maintain their existing architectural elements and general appearance with the exception that the front door will be relocated, and windows will be either added and/or removed. New second story windows will include roof skylights, a second story clerestory window on the south elevation, and second story windows and doors facing the rear yard. The project will include a new peaked roof that rises from the sides with its highest point at the center. The second story element will be located at the rear of residence and will be incorporated into the roof. The second story will have a roof pitch and exterior materials that are not consistent with the remainder of the structure so that it appears to rise above the roof as viewed primarily from street. The second story will contain a loft space and is more visible from the rear elevation. A glass door from the second story will provide access to a balcony. A colors and materials board prepared by the applicant is included as Attachment #5. Below is a list of the proposed exterior materials. 10 Report to the Planning Commission 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 4 Detail Colors and Materials Exterior White Colored Stucco / Cedar Siding Windows / Trim Black Colored Vinyl Windows Doors Cedar Wood Entrance Door Glass Garage Door and Exterior Doors with Black Colored Frames Roof Grey Colored Composition Shingles / Grey Colored TPO Membrane Trees The project arborist inventoried a total of two trees on the site which include a 52” coast redwood on the left side of the site and a 36” Douglas fir on the right side of the site. Neither of these trees are proposed for removal. A description of the trees to be preserved and the tree protection plan are included in the Arborist Report. (Attachment 2) Landscaping Proposed front yard landscaping will include a lawn, flowering shrubs, and a concrete entrance path, patio, and driveway. The existing coast redwood and the Douglas fir are incorporated into the landscape design. FINDINGS Design Review The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the site is relatively level. Minimal grading is proposed which would include construction of the driveway, entrance path, foundation for the first story addition, and contouring the site for drainage purposes. The site development is appropriate to the site’s natural constraints including one story single-family residences on adjacent sites. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that two protected trees are located on site and both trees are to be preserved and protected throughout the duration of the project. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. 11 Report to the Planning Commission 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 5 This finding can be made in the affirmative in that although the project will be taller than the adjacent single-story residences on either side and to the rear, privacy impacts because of windows above ground level that face the side adjacent neighbors are minimized using skylights that will bring light into the project’s interior without offering views out to the sides. In addition, the second story which projects above the roof has one clerestory window facing the side property to the south to minimize views toward the adjacent neighbor with no second story windows facing the side property to the north. A second story balcony is located at the rear of the structure and in the center of the building footprint. The balcony is accessed by a sliding glass door from the second story. Rear facing views are minimized by a rear setback of at least 80 feet and side facing views toward the adjacent neighbors are minimized by locating the balcony at the center of the building footprint to maximize the distance from neighboring properties and using building forms to block views and direct them toward the rear yard. There are no identified community viewsheds in the vicinity. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that although the project is a two-story residence, and is taller than adjacent structures, the project has been designed with architectural elements such as a reduced overall building height and maintaining the existing roof form and eve heights of the first story to improve the consistency and compatibility with the existing one-story residences on both sides and the predominant one-story neighborhood. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that 67 percent of the front setback area will include new landscaping including a lawn area, a concrete entrance path, patio, and driveway, and flowering shrubs. Existing protected trees including a coast redwood and a Douglas fir will be incorporated into the landscaping. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing and the orientation of the sun with respect to the location of the site will not cast shadows on adjoining properties. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative in that the design of the structure and site development plans are consistent with the Residential Design Review Handbook which contain 12 Report to the Planning Commission 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 6 informative statements, policies, and design techniques to assist property owners to comply with Saratoga’s Design Review Findings. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project in that it is not located in Hillside Residential zoning District and the average slope of the site does not exceed 10%. Neighbor Notification and Correspondence The applicant contacted adjacent neighbors regarding the project and was able to obtain seven (7) completed neighborhood review forms (Attachment #3) which included no negative project related comments. The Community Development Department mailed public notices to property owners within 500 feet of the site. In addition, the public hearing notice and description of the project was published in the Saratoga News. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single-family residence and small structures in a residential area. The project, as proposed, is for the construction of a new residence in a suburban, residential area. ATTACHMENTS 1. Resolution No. 22-007 2. Arborist Report dated September 23, 2001. 3. Neighbor Review Letters 4. Story Pole Certification 5. Materials Board 6. Project Plans 13 RESOLUTION NO: 22-007 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0015 AND ARBORIST REPORT ARB21-0082 12470 PASEO CERRO (APN 386-46-015) WHEREAS, on June 6, 2021, a Design Review application was submitted to the City of Saratoga by Anat Shmariahu for Design Review approval and City Arborist Clearance for a 1,555 square foot single story addition and a 239 square foot second story addition to an existing 1,584 square foot one-story single-family residence. The height of the project will be 21.63 feet. No protected trees are proposed for removal. WHEREAS, on December 8, 2021 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. The Planning Commission provided comments regarding the height and mass of the project with Design Review Guidelines and continued the application to date uncertain to provide an opportunity for the applicant to revise the project. WHEREAS, on February 9, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines, and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the 14 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 2 property’s natural constraints; the porch and entry are in scale with other structures in the neighborhood. Section 5: The City of Saratoga Planning Commission hereby approves PDR21-0015 and ARB21-0034, 12470 Paseo Cerro (APN 393-34-009), subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. Section 6: Unless appealed pursuant to the requirements of Article 15-90 of the Saratoga City Code, this Resolution shall become effective fifteen (15) days from the date of its adoption. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 9th day of February 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Anjali Kausar Chair, Planning Commission 15 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0015 / ARB21-0082 12470 PASEO CERRO (APN 386-46-015) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify, and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions, or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses, or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. 16 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 4 In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. COMMUNITY DEVELOPMENT DEPARTMENT 5. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 6. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Plans dated January 12, 2022. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 7. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 8. To comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 9. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 17 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 5 10. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 11. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall take into account potential damage to roots of protected trees 12. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 13. A locking mailbox approved for use by the U.S. Postal service shall be installed and in compliance with Saratoga Municipal Code section 6-25.030. The mailbox shall be installed prior to final inspection. 14. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 15. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. Contact West Valley Collection & Recycling (408-283-9250 or customerservice@westvalleyrecycles.com) to schedule delivery of a debris box. FIRE DEPARTMENT 16. The owner/applicant shall comply with all Fire Department requirements. 18 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 6 ARBORIST 17. All requirements in the City Arborist Report (ARB21-0082) dated September 23, 2021 are hereby adopted as conditions of approval and shall be implemented as part of the approved plans. ENGINEERING 18. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 19. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 20. Per Design Review PDR21-0015, no improvements in the public right-of-way are required. 21. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 22. All new/upgraded utilities shall be installed underground. 23. Applicant / Owner shall maintain the streets, sidewalks and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 24. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g. landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay-Friendly Landscaping). 25. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing storm water pollution: • Owner shall implement construction site inspection and control to prevent construction site discharges of pollutants into the storm drains per approved Erosion Control Plan. • The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non-storm water management through all phases of construction (including, but not limited to, site grading, building, and 19 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 7 finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. • City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 26. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. 27. Prior to the Building final, all Public Works conditions shall be completed per approved plans. 28. Upon the completion of this project the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the City's building inspector to be properly elevated. Such certification and verification shall be provided to the City’s Floodplain Administrator. BUILDING DEPARTMENT SUBMITTAL 29. Four (4) sets of complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. 20 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 8 DESIGN REVIEW FINDINGS PDR21-0015 / ARB21-0082 12470 PASEO CERRO (APN 386-46-015) The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the site is relatively level. Minimal grading is proposed which would include construction of the driveway, entrance path, foundation for the first story addition, and contouring the site for drainage purposes. The site development is appropriate to the site’s natural constraints including one story single-family residences on adjacent sites. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that two protected trees are located on site and both trees are to be preserved and protected throughout the duration of the project. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that although the project will be taller than the adjacent single-story residences on either side and to the rear, privacy impacts because of windows above ground level that face the side adjacent neighbors are minimized using skylights that will bring light into the project’s interior without offering views out to the sides. In addition, the second story which projects above the roof has one clerestory window facing the side property to the south to minimize views toward the adjacent neighbor with no second story windows facing the side property to the north. A second story balcony is located at the rear of the structure and in the center of the building footprint. The balcony is accessed by a sliding glass door from the second story. Rear facing views are minimized by a rear setback of at least 80 feet and side facing views toward the adjacent neighbors are minimized by locating the balcony at the center of the building footprint to maximize the distance from neighboring properties and using building forms to block views and direct them toward the rear yard. There are no identified community viewsheds in the vicinity. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. 21 12470 Paseo Cerro– Application # PDR21-0015/ARB21-0082 February 9, 2022 Page | 9 This finding can be made in the affirmative in that although the project is a two-story residence, and is taller than adjacent structures, the project has been designed with architectural elements such as a reduced overall building height and maintaining the existing roof form and eve heights of the first story to improve the consistency and compatibility with the existing one-story residences on both sides and the predominant one-story neighborhood. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that 67 percent of the front setback area will include new landscaping including a lawn area, a concrete entrance path, patio, and driveway, and flowering shrubs. Existing protected trees including a coast redwood and a Douglas fir will be incorporated into the landscaping. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing and the orientation of the sun with respect to the location of the site will not cast shadows on adjoining properties. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative in that the design of the structure and site development plans are consistent with the Residential Design Review Handbook which contain informative statements, policies, and design techniques to assist property owners to comply with Saratoga’s Design Review Findings. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project in that it is not located in Hillside Residential zoning District and the average slope of the site does not exceed 10%. 22 Community Development Department 13777 Fruitvale Avenue Saratoga, CA 95070 www.saratoga.ca.us/171/trees 831.291.1344 CITY OF SARATOGA ARBORIST APPROVAL Conditions of Approval and Tree Protection Plan Prepared by Katelyn Obana, Contract Arborist Application No.PDR21-0015/ARB21-0082 Phone: (831) 291-1344 Address:12470 Paseo Cerro Email: Katelyn.Obana@Davey.com Owner:Sunitha & Steve Ayers APN:386-46-015 Date:September 23, 2021 PROJECT SCOPE: The applicant has submitted plans to construct new first and second story additions and covered porch. No trees protected by City Code are requested for removal to construct the project. PROJECT DATA IN BRIEF: Tree security deposit –Required - $11,425 Tree protection –Required – See Conditions of Approval and attached map. Tree removals –No trees that are protected by City Code are requested or approved for removal in order to complete this project. Replacement trees –N/A ATTACHMENTS: 1 – Findings and Tree Information 2 – Conditions of Approval 3 – Map Showing Tree Protection 1 Attachment 2 23 Attachment 1: FINDINGS Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. No trees that are protected by City Code are requested for removal to construct the project. New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15-50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1.Shall include the Tree Protection Zone and Construction Impacts to Subject Trees from the arborist report by Kurt Fouts from the report dated May 16,2021; 1)The Project Data in Brief, the Conditions of Approval,and the Map showing tree protection from this report dated September 23, 2021. 2 24 Attachment 1 Continued: TREE INFORMATION Project Arborist:Kurt Fouts Date of Report:May 16, 2021 Number of protected trees inventoried:2 Number of protected trees requested for removal: 0 A table summarizing information about each tree is below. Table 1: Tree information and appraisal values from submitted arborist report dated May 16, 2021. Total Value of Appraised Trees (including neighbor trees):$45,700 Appraised Value of Removals (to be replaced):N/A Required Security Deposit (25% of tree appraisal):$11,425 3 25 Attachment 3: CONDITIONS OF APPROVAL 1.Owner, Architect, Contractor:It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2.Permit: a.Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. b.No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 3.Final Plan Sets: a.Shall include the Tree Protection Zone and Construction Impacts to Subject Trees from the arborist report by Kurt Fouts from the report dated May 16, 2021; b.Shall include the Project Data in Brief, the Conditions of Approval, and the Map showing tree protection sections of the City Contract Arborist report dated September 23, 2021. 4.Tree Protection Security Deposit: a.Is required per City Ordinance 15-50.080. b.Shall be $11,425 for tree(s)#1-2. c.Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d.May be in the form of cash, check, credit card payment or a bond. e.Shall remain in place for the duration of construction of the project. f.May be released once the project has been completed, inspected and approved by the City Arborist. 5.Tree Protection Fencing: a.Shall be installed as shown on the attached map. b.Shall be shown on the Site Plan. c.Shall be established prior to the arrival of construction equipment or materials on site. d.Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. e.Shall be posted with signs saying “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CONTRACT CITY ARBORIST, KATELYN OBANA (831) 291-1344”. f.Wherever protection is needed outside of fences, unprocessed wood chips, or approved equivalent, shall be placed to the edge of the tree’s canopy and to a depth of 6 inches. g.Call the Contract City Arborist, Katelyn Obana at (831) 291-1344 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. h.Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 6.Construction:All construction activities shall be conducted outside tree protection fencing unless permitted as conditioned below. These activities include, but are not necessarily limited to, the 4 26 following: demolition, grading, trenching for utility installation, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 7.Work inside fenced areas: a.Requires a field meeting and approval from the Contract City Arborist before performing work. b.Requires Project Arborist on site to monitor work. 8.Project Arborist: a.Shall be Kurt Fouts unless otherwise approved by the City Arborist. b.Shall visit the site every two weeks during grading, trenching or digging activities and every six weeks thereafter. A letter/email shall be provided to the City after each inspection which documents the work performed around trees, includes photos of the work in progress, and provides information on tree condition during construction. c.Shall supervise any permitted pruning or root pruning of trees on site. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. 9.Damage to protected trees that will be retained: a.Should any protected tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessary number of new trees, some of the value for trees may be paid into the City ’s Tree Fund. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b.Water loving plants and lawns are not permitted under oak tree canopies. 10.Final inspection: At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call the Contract City Arborist for a final inspection. Before scheduling a final inspection from the Contract City Arborist, have the project arborist do an inspection, prepare a letter with their findings and provide that letter to the City for the project file. 5 27 Attachment 4:Tree Protection Zone Map: 6 28 Attachment 3 29 30 31 32 33 34 35 Attachment 4 36 1/11/2022 2:35:18 PMMATERIAL12470 PASEO CERRO SARATOGA595 BOSTONSAND GLASS GARGAE DOOR BALCK FRAMEBLACK FRAMED WINDOWWOOD ENTRANCE DOOR37 1/11/2022 2:35:18 PMMATERIAL12470 PASEO CERRO SARATOGA595 BOSTONSAND GLASS GARGAE DOOR BALCK FRAMEBLACK FRAMED WINDOWWOOD ENTRANCE DOOR54 REPORT TO THE PLANNING COMMISSION 13514 Hammons Avenue Meeting Date: February 9, 2022 Application: PDR21-0008 / ARB21-0034 Address/APN: 13514 Hammons Avenue / 393-34-009 Applicant / Property Owner: Tom Sloan AIA / Kyung Mo Shin & Mi Sun Kang From: Debbie Pedro, Community Development Director Report Prepared By: Christopher Riordan, Senior Planner 55 Report to the Planning Commission 13514 Hammons Avenue– Application #s PDR21-0008 / ARB21-0034 February 9, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a project which includes removal of an existing 3,972 square foot one story single-family residence and the construction of a new 4,206 square foot one story single-family residence with an overall height of 23’-9”. A protected apple tree and a Japanese maple tree are proposed for removal. STAFF RECOMMENDATION Adopt Resolution No. 22-001 approving the project subject to conditions of approval included in Attachment 1. Pursuant to City Code Section 15-45.060(a)(3), Design Review Approval by the Planning Commission is required as the project includes a new structure over eighteen feet in height. PROJECT DATA Gross/Net Site Area: 16,691 sq. ft. gross/net (.302 acres) Average Site Slope: Level Site General Plan Designation: M-10 (Medium Density Residential) Zoning: R-1-10,000 Proposed Allowed/Required Site Coverage Residence/Garage Walkways, Decks, Steps Permeable Surfaces Total Proposed (structures) 4,206 sq. ft. 1,737 sq. ft. 993 sq. ft. 6,936 sq. ft. (41%) 10,014 sq. ft. (60%) Floor Area Main Residence Living Area Attached Garage Total Floor Area 3,467 sq. ft. 739 sq. ft. 4,206 sq. ft. 4,206 sq. ft. Height 23’-9” 26’ Setbacks Front: Interior Side: Exterior Side: Rear: 25’-7.5” 11’-8” 25’-1” 10’-3” 25’ 10’ 25’ 10’ Grading Cut 1 CY Fill 1 CY Export 0 CY No grading limit in the R-1-10,000 zoning district. SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The project site is a corner lot located at the intersection of Hammons and Thelma Avenues in the R-1-10,000 zoning district. The site contains an existing 3,972 square feet one-story single- family residence. A total of five (5) protected trees were inventoried by the project arborist including one coast live oak, one apple, and three Japanese maples. The coast live oak is located 56 Report to the Planning Commission 13514 Hammons Avenue– Application #s PDR21-0008 / ARB21-0034 February 9, 2022 Page | 3 on the adjacent site at 20221 Thelma Avenue and a potion of its canopy overhangs the project site. The site is not located in a geologic unstable area as depicted on the City’s Ground Movement Potential Map. Surrounding uses in the immediate vicinity include predominantly one-story single-family residences with two-story single-family homes located on adjacent streets. Background The Planning Commission previously reviewed the project at their meeting of January 12, 2022. After receiving public testimony from both the applicant and neighboring property owners, the Commission discussed the project and expressed concern that the height of the residence and the size of the roof contributed to the project’s overall mass that was not in character with the neighborhood. The Commission continued the project to their meeting of February 9, 2022 to provide an opportunity for the applicant to make modifications to the design and return to the Commission with revised plans. To respond to the Commissions concerns, the applicant modified the slope of the primary hipped roof form from 12:12 to 10:12 which had the effect of reducing the mass of the roof. The two front facing gables and the rear facing gable maintain their 12:12 roof forms however, these elements are shorter architectural elements that don’t contribute significantly to the project’s overall mass. In addition, the finished floor height was reduced from 409’ to 408.58’. The effect of modifying the slope of the roof and lowering the height of the finished floor reduced the height of the proposed residence from 25’-10.5” to 23’-9”, for a total height reduction of 2’-1.5”. The exterior elevations on pages A-4.0 and A-4.1 of the project plans (Attachment 6) include the outline of the previous roof design to illustrate how the design modifications reduced the height and mass of the project. Project Description The architectural style of the proposed residence can best be described as “French Eclectic”. Identifying features of this architectural style include a tall, steeply pitched hipped roof without a dominant front-facing cross gable, arched windows and doors, and the use of brick, stone, or stucco wall cladding. The elements of the project which best support the French Eclectic design include a steeply pitched (10:12 slope) symmetrical hipped roof, a horizontal building footprint, a combination of both arched and square doors and windows, and exterior materials including both stucco and stone. Exterior materials include grey colored asphalt roof shingles, tan colored stucco, the use of stone on the entry element and an architectural projection of the front façade, wood shutters, aluminum clad windows, walnut-stained front entrance door, and carriage style wood garage doors. Vehicular access would be from Hammons Avenue. A three-foot-tall garden wall with a stucco exterior to match the color of the residence would be located adjacent to both streets. A colors and materials board prepared by the applicant is included as Attachment #5. Below is a list of the proposed exterior materials. 57 Report to the Planning Commission 13514 Hammons Avenue– Application #s PDR21-0008 / ARB21-0034 February 9, 2022 Page | 4 Detail Colors and Materials Exterior Tan Color Smooth Plaster Windows / Trim Grey Colored Aluminum Clad Windows Doors Walnut Stained Wood Entrance Door Brown-Stained Wood Carriage Garage Doors Roofing Dark Grey Asphalt Composite Roof Shingles Railings Dark Bronze Colored Wrought Iron Trees The project arborist inventoried a total of five trees on site. As determined by the City Arborist, two (2) protected trees including an apple tree and a Japanese maple are either in poor condition or conflict with the location of the proposed driveway and are recommended for removal. All remaining protected trees would be fenced and preserved prior to building permit issuance and throughout the duration of the project. Tree protection fencing is required to be installed prior to the issuance of building permits. Details of the arborist’s findings and description of the trees to be removed and those to be preserved are included in the Arborist Report (Attachment 2). Landscaping Proposed front yard landscaping would feature predominantly drought tolerant ground covers, flowering annuals, and native shrubs. Trees to be planted include eight Italian cypress, four crepe myrtles, three coast redwoods, three madrone, two magnolias, and a variety of fruit trees including lemon, mandarin, persimmon, and date. FINDINGS The findings required for issuance of a Design Review Approval pursuant to City Code Section Article 15-45.080 are set forth below and the Applicant has met the burden of proof to support making all of those required findings: a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be limited to leveling the site to increase the size of the existing building pad and contouring the site to direct stormwater to landscaping and retention areas. Grading is minimized as the site is relatively level and the new structure will be located in approximately the same location as the existing structure to be removed. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the number of protected trees to be removed is limited to one apple tree and one Japanese maple tree which were evaluated by 58 Report to the Planning Commission 13514 Hammons Avenue– Application #s PDR21-0008 / ARB21-0034 February 9, 2022 Page | 5 the City Arborist as being in poor condition or conflict with the project. Tree protection fencing is required to be installed to protect the remaining three protected trees prior to the issuance of building permits and will remain in place for project duration. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the project is a single-story structure with no second story windows or elevated decks or balconies to impact the privacy of adjoining properties. Views of adjacent properties will be minimized by the location of existing and proposed trees and shrubs adjacent to both interior property lines. No community view sheds are in the vicinity of the project. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that even though the project will be a single- story structure, the proposed roof height of 23’-9” is taller than the existing homes on adjacent properties. The difference in building height and the perception of mass and height of the structure is reduced by concentrating the building height towards the center of the lot with reduced height roof forms for both the left and rear architectural elements to smooth the height transition to the adjacent homes with lower roof and plate heights. The architectural elements of the structure are true to the French Eclectic style with steeply pitched roof forms and projections to reduce the perception of mass. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the landscape design minimizes the percentage of hardscape in the front and exterior side setback areas. Proposed landscaping in the front setback area will include madrone trees, crepe myrtles, Japanese maple, and three coast redwoods and shrubs and flowers such as photinia and purple Chinese fringe flowers. Landscaping in the street side yard setback area will include delta blue grass, roses, lemon trees, magnolia, and numerous flowering plants and shrubs. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing and the project meets or exceeds required setbacks. 59 Report to the Planning Commission 13514 Hammons Avenue– Application #s PDR21-0008 / ARB21-0034 February 9, 2022 Page | 6 g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative in that the proposed project incorporates applicable design policies and techniques from the Residential Design Handbook. The overall mass and height of the structure are mitigated by the design and its architectural elements; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well- composed, understated manner. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. Neighbor Notification and Correspondence 20269 Thelma Neighborhood notification forms and project related comments are included as Attachment 3. An adjacent property owner at 20269 Thelma Avenue provided comments regarding the square footage and height of the project. The neighbor asserts that 1) the square footage of the project exceeds the allowable floor area for the site, 2) that the height of the project is too tall, 3) that a two-story project could be constructed on the site in the future, and 4) that the project may not provide the minimum 10-foot interior setback. The square footage of the site is 16,691 square feet with an allowable floor area of 4,206 square feet. The proposed square footage is 4,206 square feet. The attic space is not habitable or accessible and is not included in the projects total floor area. The allowable building height is 26 feet and the proposed height of 23’-9” is under the maximum allowable height. The project is taller than adjacent residences and staff is able to make the findings due to the design of the project to support the proposed height. The required side and rear setback for a corner lot in the R-1-10,000 zoning district are both 10 feet and the projects rear, and side setbacks exceed 10 feet. The project could be converted into a two-story residence in the future and such a project would require design review approval by the Planning Commission. The public hearing notice for the January 12, 2022 Planning Commission meeting and description of the project was published in the Saratoga News and notices were mailed to all property owners within 500 feet of the project site. The project was continued to a date certain (February 9, 2022) and no additional public notices were provided. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources 60 Report to the Planning Commission 13514 Hammons Avenue– Application #s PDR21-0008 / ARB21-0034 February 9, 2022 Page | 7 Code (CEQA). This exemption allows for the construction of three single-family residences in a residential area. The project, as proposed, is for the construction of a new residence in a suburban, residential area. ATTACHMENTS 1. Resolution No. 22-001 2. Arborist Report dated November 23, 2021 3. Neighbor Comments and Project Notification Forms 4. Story Pole Certification 5. Materials Board 6. Project Plans 61 RESOLUTION NO: 22-001 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0008 AND ARBORIST REPORT ARB21-0034 13514 HAMMONS AVENUE (APN 393-34-009) WHEREAS, on March 24, 2021 an application was submitted by Tom Sloan (Applicant) on behalf of Kyung Mo Shin and Mi Sun Kang (Owners) requesting Design Review and Arborist Report approval to construct a new 4,206 square foot one-story single-family residence. Two protected trees are proposed for removal. The site is located within the R-1-10,000 zoning district. WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA) and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on January 12, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. The Planning Commission provided comments regarding the height and mass of the project with respect to the character of the existing neighborhood and continued the application to their meeting of February 9, 2022 to provide an opportunity for the applicant to revise the project. WHEREAS, on February 9, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. 62 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 2 Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints; the porch and entry are in scale with other structures in the neighborhood. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. Section 5: The City of Saratoga Planning Commission hereby approves PDR21-0008 and ARB21-0034, 13514 Hammons Avenue (APN 393-34-009), subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 9th day of February 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Anjali Kausar Chair, Planning Commission 63 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0008 / ARB21-0034 13514 HAMMONS AVENUE (APN 393-34-009) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify, and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions, or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses, or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. 64 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 4 In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. COMMUNITY DEVELOPMENT DEPARTMENT ** Permanent Condition 5. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 6. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Plans dated January 28, 2022. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 7. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 8. To comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 9. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 65 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 5 10. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 11. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall take into account potential damage to roots of protected trees 12. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 13. ** This condition is permanent. The attic area shall not be made accessible or improved in any manner that would cause the space to be considered “habitable” per Section 15-06.280 of the Saratoga City Code. 14. A locking mailbox approved for use by the U.S. Postal service shall be installed and in compliance with Saratoga Municipal Code section 6-25.030. The mailbox shall be installed prior to final inspection. 15. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 16. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. Contact West Valley Collection & Recycling (408-283-9250 or customerservice@westvalleyrecycles.com) to schedule delivery of a debris box. FIRE DEPARTMENT 17. The owner/applicant shall comply with all Fire Department requirements. 66 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 6 ARBORIST 18. All requirements in the City Arborist Report (ARB21-0037) dated November 23, 2021 are hereby adopted as conditions of approval and shall be implemented as part of the approved plans. ENGINEERING 19. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 20. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 21. Applicant / Owner shall make the following improvements in the City right-of-way: a. Install a new driveway approach per City Standard Detail 205 & 206 for the new driveway. b. Remove existing unused driveway approach and replace with new vertical curb and gutter per City Standard Detail 203. Removal of existing rolled curb concrete shall be from joint to joint within the property line. Curb and gutter shall be placed over a minimum of six inches (6”) of base. It shall be compacted to 95% relative compaction before placing concrete. See City of Saratoga Standard details. See City of Saratoga Standard Details for removal and new installation. New flow line shall conform to existing flow lines and grade. 22. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 23. All new/upgraded utilities shall be installed underground. 24. Applicant / Owner shall maintain the streets, sidewalks, and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 25. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g., landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay-Friendly Landscaping). 67 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 7 26. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing storm water pollution: • Owner shall implement construction site inspection and control to prevent construction site discharges of pollutants into the storm drains per approved Erosion Control Plan. • The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non-storm water management through all phases of construction (including, but not limited to, site grading, building, and finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. • City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 27. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. 28. Prior to the Building final, all Public Works conditions shall be completed per approved plans. 29. Upon the completion of this project the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the City's building inspector to be properly elevated. Such certification and verification shall be provided to the City’s Floodplain Administrator. BUILDING DEPARTMENT SUBMITTAL 30. Four (4) sets of complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. 68 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 8 DESIGN REVIEW FINDINGS PDR21-0008/ARB21-0034 13514 HAMMONDS AVENUE (393-34-009) The findings required for issuance of a Design Review Approval pursuant to City Code Section Article 15-45.080 are set forth below: a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be limited to leveling the site to increase the size of the existing building pad and contouring the site to direct stormwater to landscaping and retention areas. Grading is minimized as the site is relatively level and the new structure will be located in approximately the same location as the existing structure to be removed. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the number of protected trees to be removed is limited to one apple tree and one Japanese maple tree which were evaluated by the City Arborist as being in poor condition or conflict with the project. Tree protection fencing is required to be installed to protect the remaining three protected trees prior to the issuance of building permits and will remain in place for project duration. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the project is a single-story structure with no second story windows or elevated decks or balconies to impact the privacy of adjoining properties. Views of adjacent properties will be minimized by the location of existing and proposed trees and shrubs adjacent to both interior property lines. No community view sheds are in the vicinity of the project. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that even though the project will be a single- story structure, the proposed roof height of 23’-9” is taller than the existing homes on adjacent properties. The difference in building height and the perception of mass and height of the structure is reduced by concentrating the building height towards the center of the lot 69 13514 Hammons Avenue– Application # PDR21-0008/ ARB21-0034 February 9, 2022 Page | 9 with reduced height roof forms for both the left and rear architectural elements to smooth the height transition to the adjacent homes with lower roof and plate heights. The architectural elements of the structure are true to the French Eclectic style with steeply pitched roof forms and projections to reduce the perception of mass. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the landscape design minimizes the percentage of hardscape in the front and exterior side setback areas. Proposed landscaping in the front setback area will include madrone trees, crepe myrtles, Japanese maple, and three coast redwoods and shrubs and flowers such as photinia and purple Chinese fringe flowers. Landscaping in the street side yard setback area will include delta blue grass, roses, lemon trees, magnolia, and numerous flowering plants and shrubs. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing and the project meets or exceeds required setbacks. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative in that the proposed project incorporates applicable design policies and techniques from the Residential Design Handbook. The overall mass and height of the structure are mitigated by the design and its architectural elements; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well- composed, understated manner. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. 70 Community Development Department 13777 Fruitvale Avenue Saratoga, CA 95070 www.saratoga.ca.us/171/trees 408.868.1276 CITY OF SARATOGA ARBORIST APPROVAL Conditions of Approval and Tree Protection Plan Prepared by Christina Fusco, City Arborist Application No. ARB21-0037 Phone: (408) 868-1276 Address: 13514 Hammons Ave Email: cfusco@saratoga.ca.us Owner: SHIN KYUNG MO AND KANG MI SUN APN: 393-34-009 Date: November 23, 2021 PROJECT SCOPE: The applicant has submitted plans to demolish the existing home and construct a new one-story home. Two trees are requested for removal to construct the project. PROJECT DATA IN BRIEF: Tree security deposit – Required - $3,820 Tree protection – Required – See Conditions of Approval and attached map. Tree removals – Trees # 2 and #3 are approved for removal once building permits have been issued. Replacement trees – Required = $3,250 ATTACHMENTS: 1 – Findings 2 – Tree Removal Criteria 3 – Tree Information 4 – Conditions of Approval 5 – Map Showing Tree Protection 1 of 8 Attachment 2 71 13514 Hammons Ave Attachment 1 FINDINGS: Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. One apple and one Japanese maple are in conflict with the project and meet the City’s criteria allowing them to be removed and replaced as part of the project, once building division permits have been obtained. Attachment 2 contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No. Species Criteria met Comments 2 Malus domestica apple 1, 6, 9 3 Acer palmatum Japanese maple 1, 6, 9 New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15- 50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1)The tree information and recommendations, and the map showing tree protection from the submitted arborist report dated December 9, 2021 and revised October 25, 2021; 2)The Project Data in Brief and the Conditions of Approval from this report dated November 23, 2021. 2 of 8 72 13514 Hammons Ave Attachment 2 TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1)The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2)The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. (3)The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. (4)The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. (5)The age and number of healthy trees the property is able to support according to good forestry practices. (6)Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7)Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8)Any other information relevant to the public health, safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9)The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. (10)The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. (11)The necessity to remove a tree following the creation of defensible space within 100 feet of a structure located within the Wildland Urban Interface, in accordance with defensible space standards established by CAL FIRE or as determined by Santa Clara County Fire Department, and that risk of increased wildfire cannot reasonably be addressed through maintenance or without tree removal. 3 of 8 73 13514 Hammons Ave Attachment 3 TREE INFORMATION: Project Arborist: Richard Gessner Date of Report: December 9, 2021 and revised October 25, 2021; Number of protected trees inventoried: 5 Number of protected trees requested for removal: 2 A table summarizing information about each tree is below. Table 2: Tree information from submitted arborist report dated December 9, 2021, and revised October 25, 2021. 4 of 8 74 13514 Hammons Ave Attachment 4 CONDITIONS OF APPROVAL 1.Owner, Architect, Contractor: It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2.Permit: a.Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. b.No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 3.Final Plan Sets: a.Shall include the tree information and protection recommendations from the arborist report by Richard Gessner dated December 9, 2021, and revised October 25, 2021copied onto a plan sheet. b.Shall include the Project Data in Brief, the Conditions of Approval, and the map showing tree protection sections of the City Arborist report dated November 23, 2021. 4.Tree Protection Security Deposit: a.Is required per City Ordinance 15-50.080. b.Shall be $3,820 for tree(s) 1, 4, and 5. c.Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d.May be in the form of cash, check, or a bond. e.Shall remain in place for the duration of construction of the project. f.May be released once the project has been completed, inspected, and approved by the City Arborist. 5.Tree Protection Fencing: a.Shall be installed as shown on the attached map. b.Shall be shown on the Site Plan. c.Shall be established prior to the arrival of construction equipment or materials on site. d.Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. e.Shall be posted with signs saying, “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, CHRISTINA FUSCO (408) 868- 1276”. f.Call City Arborist, Christina Fusco at (408) 868-1276 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. g.Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 5 of 8 75 13514 Hammons Ave Attachment 4 6.Construction: All construction activities shall be conducted outside tree protection fencing unless permitted as conditioned below. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching for utility installation, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 7.Work inside fenced areas: a. Requires a field meeting and approval from City Arborist before performing work. b.Requires Project Arborist on site to monitor work. 8.Project Arborist: a.Shall be Richard Gessner unless otherwise approved by the City Arborist. b.Shall visit the site every two weeks during grading, trenching or digging activities and every six weeks thereafter. A letter/email shall be provided to the City after each inspection which documents the work performed around trees, includes photos of the work in progress, and provides information on tree condition during construction. c.Shall supervise any permitted pruning or root pruning of trees on site. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. 9.Tree removal: Trees 2 and 3 meet the criteria for removal and may be removed once building division permits have been obtained. 10.New trees: a.New trees equal to $3,250 shall be planted as part of the project before final inspection and occupancy of the new home. New trees may be of any species and planted anywhere on the property as long as they do not encroach on retained trees. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b.Trees shall be replaced on or off site according to good forestry practices and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. 11.Damage to protected trees that will be retained: a.Should any protected tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessary number of new trees, some of the value for trees may be paid into the City’s Tree Fund. Replacement values for new trees are listed below. b.Water loving plants and lawns are not permitted under oak tree canopies. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 6 of 8 76 13514 Hammons Ave Attachment 4 12.Final inspection: At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call City Arborist for a final inspection. Before scheduling a final inspection from the City Arborist, have the project arborist do an inspection, prepare a letter with their findings and provide that letter to the City for the project file. 7 of 8 77  AƩachment 5  13514 Hammons Ave 8 of 878 City of Saratoga Neighbbr Notiflcation Form Project Address: 13514 Hammons Avenue, Saratoqa, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an oppoftunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law, The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name: Neighbor Address: Neighbor Contact Info: (phone or email): - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 b/>0fr My signature below certifies that I am aware of the proposal. NEIGHBOR SIGNATURE: Revised February 2Ot4 Attachment 3 79 City of Saratoga Neighbbr Notifl cation Form Project Address: 13514 Hammons Avenue, Saratoqa, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an oppoftunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Ptease contact the City at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining propefty owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. NelshborName: NeishborContactlnfo:(phoneoremait) - This enables the City to contact you if they have any questtons Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 My signature below certifies that I am aware of loposal. NEIGHBOR SIGNATURE: Revised February 20L4 80 City of Sarctoga Neighbor Notiflcation Form Project Address: 13514 Hammons Avenue, Saratoqa, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an oppoftunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law, The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Pf ease contact the City at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neishbor Name: 'ttl-n *Lhr,c, C hr' ctn'f Date: Neighbor Address: -Th€ /r"nn Ate Si.v ,..fa' ),Lt C A cl 5 c 7 D Neishbor contact Info: (phone or emait): - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; t3777 Fruitvale Avenue; Saratoga CA 95070 My signature below certifies that I am aware of the proposal. NEIGHBOR SIGNATURE: Revised February 2Ot4 81 City of Sarctoga Neighbor Notifl cation Form Project Address: 13514 Hammons Avenue, Saratoqa, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an oppoftunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Pfease contact the City at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name:cLr Neighbor Address: 4Li Neighbor Contact Info: (phone or email): - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 proposal. Revised February 2OI4 82 City of Sarctoga Neighbor Notifi cation Form Project Address: 13514 Hammons Avenue, saratoqa, cA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an oppoftunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves fonvard. Architectural Plans are protected under copyright law. The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the city at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name: Neishbor Address: h\ der C-l Nelshborcontactlnfo: ( - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Depaftment; 13777 Fruitvale Avenue; Saratoga CA 95070 My signature below certifies that I am aware of the proposal. NEIGHBOR SIGNATURE: Revised February 2OI4 83 City of Sar:atoga Neighbor Notification Form Project Address: 13514 Hammons Avenue, Saratoqa, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an oppoftunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves fonryard. Architectural Plans are protected under copyright law, The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining property owners and the propefty across the street from the project address. The City will send an additional notice to neighbors prior to a decision being made on the project. Neighbor Name: owner(s) adjacent >t Neighbor Address: -fl€L/ttA Neighbor Contact Info: (phone or email): - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Depaftment; 13777 Fruitvale Avenue; Saratoga CA 95070 My signature below ceftifies that I am awa proposal. NEIGHBOR SIGNATURE: Revised February 2OL4 84 City of Sarctoga Neighbor Notification Form Project Address: 13514 Hammons Avenue, Saratoqa, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an opportunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an oppoftunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to view the plans but is not required to give you a physical copy. Once the apptication is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-8 68-L222if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name:C J oN Gj filfitr' Neighbor Address:rAELtqA AVr, 5fit2A1/)44,il lep7o Neighbor Contact Info: (phone or email): - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 My signature below certifies that I am aware of the proposal. NEIGHBOR SIGNATURE: Revised Februa ry 2OL4 85 Planning Commission Comments Form Your Name Philip Fries Phone Number Comments Application PDR21-0008/ARB21-0034 re: 13514 Hammons Avenue (393-34-009) Dear Gentlepersons: I write to you in response to a notice of hearing before the City of Saratoga planning commission that I just received for the design of the subject property. I am sending this response to express concerns on the new proposed design, since I will not be able to join the City of Saratoga meeting that has been scheduled for January 12, 2022. I believe the proposed design of the home for the property is not desirable to the area or surrounding properties. The proposed design also does not appear to conform with the City of Saratoga’s current design requirements. For these reasons, I believe an approval should not be granted by the City of Saratoga to the proposed design. First, the design of the new house seems to be way too large for the property lot. According the City of Saratoga’s current planning department rules, the maximum permitted living floor allowance for the property is 3,540 sq feet (3,200 sq feet plus 340 sq feet), assuming this is a 12,000 sq foot lot with a R-1- 10,000 designation. Further, the use of the 25 foot, 10 inch height may not take into consideration the City of Saratoga’s planning commission rules that require living space with an interior floor to ceiling height of 15 feet or greater be double counted. If double counting of such space occurs (if there are heights of 15 feet or greater), then the square footage would be much more. Based on the foregoing, it appears that the planned living floor allowance may substantially exceed the permitted living floor allowance that exists under the City of Saratoga’s planning 86 department rules. Second and more importantly, the height of the planned new home is way too tall. A height of 25 feet, 10 inches exceeds substantially the height of adjacent and surrounding homes, and will create viewing obstructions of trees, skies, etc. in a manner that will affect detrimentally the aesthetic appearance of the area. This proposed new home will stand out as being way too tall for the property lot and will cause major viewing obstructions to property owners. Third, the design plans indicate that the home will be a one- story home. If construction occurs with a 25 foot, 10 inch height, there is nothing that may prevent such house from being converted at a later time to a two story house through an internal renovation that would not change the exterior of the house or otherwise be visible to property owners. Lastly, I understand that there is a required 10 foot interior side setback that must occur. From a brief look at the poles and flags placed on the site, it’s not clear that that this setback requirement is met. The plan should have a minimum 10 foot interior side setback, if it doesn’t already have that setback. 87 Attachment 4 88 EXTERIOR WALL FINISH STUCCO PLASTER- BEACHSIDE VILLA COLOR EXTERIOR WALL FINISH : -MCGREGOR LAKE STONE -STONE VENEER WINDOWS & EXTERIOR DOORS: ALUMINUM CLAD - 'CLAY' ANODIZED ALUMINUM CONCRETE AT PATIOS, STEPS, WALKS : GREY POURED IN PLACE CONCRETE 3-05-21 ROOFING ASPHALT COMPOSITION ROOFING- CERTAINTEED PRESIDENTIAL TL - COUNTRY GRAY EXTERIOR FRONT DOOR WOOD - WALNUT DARK STAINED DRIVEWAY, WALKWAYS, PATIOS PERMEABLE PAVERS ECO-FRIENDLY 'PERMEABLE MISSION PAVEMENT' - PREMIUM GRANITE BAY COLOR BY 'BASALITE'PATTERNCOLORSTEEL RAILING -DARK BRONZE COLORGARAGE DOORS WOOD 'CARRIAGE' STYLE DOORS - 'HAMPTON SAGE' COLORSTYLECOLOR 1475 S BASCOM AVE SUITE 208 • CAMPBELL, CA 95008 • (408) 871-1071 PH METRO GROUP DESIGN 13514 Hammons ave. Saratoga, CA 95070 SHIN RESIDENCE Attachment 3 89 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-0.0 Shin Residence 1-12-22.pln1/28/20224:30 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 A-0.0 C-1.0 C-2.0 C-2.1 C-3.0 A-1.0 A-1.1 A-1.2 A-1.3 A-2.0 A-3.0 A-4.0 A-4.1 A-5.0 COVER SHEET BEST MANAGEMENT PRACTICES GRADING AND DRAINAGE PLAN DETAILS TOPOGRAPHIC SURVEY STREET PROFILES STREETSCAPE ELEVATIONS PROPOSED SITE PLAN DEMOLITION SITE PLAN PROPOSED FLOOR PLAN PROPOSED ROOF PLAN EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS SECTIONS PROJECT SITE GENERAL NOTES VICINITY MAPPROJECT INFORMATION AS-NOTED COVER SHEET AREA TABULATIONS GENERAL NOTES PROJECT INFORMATION AREA TABULATIONS PROJECT DESCRIPTION VICINITY MAP SHEET INDEX CONSULTANT DIRECTORY CONSULTANT DIRECTORY PROJECT DESCRIPTION ARCHITECT METRO DESIGN GROUP CONTACT :TOM SLOAN A.I.A. 1475 S. BASCOM AVE. # 208 CAMPBELL, CALIFORNIA 95008 (408)871-1071 PHONE PROPERTY OWNERS PHONE MAILING ADDRESS PROJECT ADDRESS A.P.N. ZONING LOCATED WITHIN DESIGNATED WILDLAND URBAN INTERFACE FIRE AREA AGE OF HOME SETBACK REQUIREMENTS MAX HEIGHT ALLOWABLE / PROPOSED STORIES CONSTRUCTION TYPE OCCUPANCY FIRE SPRINKLERS EXISTING USE KYUNG SHIN (408)489-5017 13514 HAMMONS AVENUE SARATOGA, CA 95070 13514 HAMMONS AVENUE SARATOGA, CA 95070 393-34-009 R - 1-10,000 NO 1956 REQUIRED SIDE EXTERIOR: 25'-0" FRONT: 25'-0" SIDE INTERIOR: 10'-0" REAR: 10'-0" PROPOSED SIDE EXTERIOR: 25'-1" FRONT: 25'-7 1/2" SIDE INTERIOR: 11'-8" REAR: 10'-3" ALLOWED PROPOSED 26'-0" 23'-9" 2 1 V-B R-3/U REQUIRED (NFPA-13D) EXISTING 1 STORY RESIDENCE SHEET INDEX ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING CODES, AS WELL AS ALL APPLICABLE STATE CODES & LOCAL CITY ORDINANCES, 2019 CALIFORNIA BUILDING CODE (C.B.C.) 2019 CALIFORNIA RESIDENTIAL CODE (C.R.C.) 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) 2019 CALIFORNIA PLUMBING CODE (C.P.C.) 2019 CALIFORNIA MECHANICAL CODE (C.M.C.) 2019 CALIFORNIA FIRE CODE (C.F.C.) 2019 CALIFORNIA ENERGY CODE (C.E.C.) 2019 CALIFORNIA GREEN CODE (C.G.C.) NOTHING ON THE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES & REGULATIONS. GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL EXAMINE THOROUGHLY THE SITE AND SATISFY THEMSELVES AS TO THE CONDITIONS TO WHICH THE WORK IS TO BE PERFORMED. THE CONTRACTOR SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING HIS WORK, AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. NO EXTRA COST TO THE OWNER WILL BE ALLOWED RESULTING FROM HIS NEGLIGENCE TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS AFFECTING HIS WORK. CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN ON THE DRAWINGS BY TAKING FIELD MEASUREMENTS; FOR PROPER FIT AND ATTACHMENT OF ALL PARTS IS REQUIRED. SHOULD THERE BE ANY DISCREPANCIES, IMMEDIATELY REPORT TO THE ARCHITECT IN WRITING PRIOR TO COMMENCEMENT OF ANY RELATED WORK. IN THE EVENT OF THE CONTRACTOR'S FAILURE TO DO SO, THE CONTRACTOR SHALL BE FULLY AND SOLELY RESPONSIBLE FOR THE CORRECTION OR ADJUSTMENT OF ANY SUCH RELATED WORK OR ERRORS. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DRAWINGS. MINOR DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS ARE TO BE EXPECTED. CONDITIONS REQUIRING CLARIFICATION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. CONTRACTOR AND ALL SUBCONTRACTORS SHALL INSTALL OR APPLY, AND PROTECT ALL PRODUCTS, MATERIALS, PROCESSES, METHODS, COATINGS, EQUIPMENT, APPLIANCES, HARDWARE, SOFTWARE, ETC. IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, DETAILS & INSTRUCTIONS, TYPICAL. ALL MANUALS OR INSTRUCTIONS PROVIDED BY THESE MANUFACTURER'S FOR PROPER OPERATION AND MAINTENANCE OF THE ABOVE ARE TO BE DELIVERED TO THE OWNER AT THE COMPLETION AND FINAL INSPECTION OF THE PROJECT. CONTRACTOR SHALL VERIFY THE QUANTITY, ROUGH OPENINGS AND TYPES OF DOORS AND WINDOW AND DOOR SCHEDULES IN RELATION TO FRAMING PER FIELD PRIOR TO ORDERING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINT CONTAINERS MUST REMAIN ON THE SITE FOR FIELD VERIFICATION BY THE BUILDING INSPECTOR. PER CGBSC SEC. 4.504.2.4 PRIOR TO FINAL INSPECTION, A LETTER SIGNED BY THE GENERAL CONTRACTOR OR THE OWNER/BUILDER (FOR ANY OWNER/BUILDER) PROJECTS MUST BE PROVIDED TO THE CITY OF SARATOGA BUILDING OFFICIAL CERTIFYING THAT ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AEROSOL PAINTS, AEROSOL COATINGS, CARPET SYSTEMS (INCLUDING CARPETING, CUSHION AND ADHESIVE), RESILIENT FLOORING SYSTEMS, AND COMPOSITE WOOD PRODUCTS INSTALLED ON THIS PROJECT ARE WITHIN THE EMISSION LIMITS SPECIFIED IN CGBSC SECTION 4.504. 1.CODES AND REGULATIONS 2.SITE VERIFICATION 3.MEASUREMENTS 4.DIMENSIONS 5.DISCREPANCIES 6.MANUFACTURER'S SPECIFICATIONS 7.WINDOWS AND DOORS 8.CALGREEN STANDARDS DEMOLITION OF EXISTING SINGLE FAMILY RESIDENCE AND HARDSCAPE WITH REMOVAL OF 9 TREES. CONSTRUCTION OF A NEW SINGLE FAMILY RESIDENCE WITH HARDSCAPE AND LANDSCAPE FEATURES. EG 2% MIN, AWAY FROM THE STRUCTURESLOPE AT LANDSCAPE AREAS: SLOPE AT PAVED AREAS:2% MIN, AWAY FROM THE STRUCTURE 1% MIN, AWAY FROM THE STRUCTURESLOPE AT LANDING AREAS: 2.FLOOR AREA PROPOSED FLOOR AREA MAIN FLOOR 3,467 SF GARAGE 739 SF TOTAL AREA 4,206 SF 3.SITE COVERAGE IMPERVIOUS SURFACES BUILDING COVERAGE WALKWAYS, DECKS, STEPS TOTAL AREA PERVIOUS SURFACES PERMEABLE PAVER DRIVEWAY PERMEABLE WALKWAY/PATIO TOTAL AREA SITE COVERAGE TOTAL 4.PARKING SPACE PROPOSED EXISTING 3 COVERED AT GARAGE 2 COVERED AT GARAGE FLOOR AREA OF EXISTING BUILDINGS TO BE REMOVED MAIN FLOOR GARAGE TOTAL AREA 3,566 SF 406 SF 3,972 SF 4,206 SF 1,737 SF 5943 SF 3,972 SF 3,276 SF 7,248 SF EXISTING PROPOSED 1.SITE AREA GROSS AREA:16,691 SF NET AREA : 16,691 SF MAXIMUM SITE COVERAGE FOR R-1-10,000 = 60% MAX SITE COVERAGE: 10,015 SF ALLOWABLE FLOOR AREA:4,206 SF AVERAGE SLOPE OF ENTIRE SITE = 2% 5.HEIGHT LOWEST ELEVATION PT. AT THE BUILDING'S EDGE FROM NATURAL GRADE = 405.90' HIGHEST ELEVATION PT. AT THE BUILDING'S EDGE FROM NATURAL GRADE = 407.80' AVERAGE ELEVATION PT. (BASED ON HIGHEST AND LOWEST POINTS) = 406.85' TOP MOST ELEVATION PT. = 432.73' 0 SF 0 SF 0 SF 7,248 SF 1,173 X 50% = 586 SF 815 X 50% = 407 SF 993 SF 6936 SF S = .00229(I)(L) A 2% = .00229(1)(3.3) .383 TOPO SURVEY & BOUNDARIES ALPHA LAND SURVEYS, INC. JEAN-PAUL HAPPEE, PLS 8807 4444 SCOTTS VALLEY DR. #7 SCOTTS VALLEY, CA 95066 (831)438-4453 GEOTECHNICAL ENGINEERING POLLAK ENGINEERING, INC. ROBERT POLLAK, P.E. 61 EAST MAIN ST.,SUITE D LOS GATOS, CA 95030 (408)499-5589 LANDSCAPE ARCHITECT AMBIENCE GARDEN DESIGN TINA JAUREGUI 530 LAWRENCE EXPWY MAILBOX #377 SUNNYVALE, CA 94085 (408)990-6999 Submitted to CDD on 1.28.22 90 Construction Best Management Practices (BMPs) Construction projects are required to implement year-round stormwater BMPs. Non-Hazardous Materials Berm and cover stockpiles of sand, dirt or other construction material ‰ with tarps when rain is forecast or when they are not in use. Use (but don’t overuse) reclaimed water for dust control. ‰ Ensure dust control water doesn’t leave site or discharge to storm ‰ drains. Hazardous Materials Label all hazardous materials and hazardous wastes (such as ‰ pesticides, paints, thinners, solvents, fuel, oil, and antifreeze) in accordance with City, County, State and Federal regulations. Store hazardous materials and wastes in water tight containers, store ‰ in appropriate secondary containment, and cover them at the end of every work day or during wet weather or when rain is forecast. Follow manufacturer’s application instructions for hazardous ‰ materials and do not use more than necessary. Do not apply chemicals outdoors when rain is forecast within 24 hours. Arrange for appropriate disposal of all hazardous wastes. ‰ Waste Management Cover and maintain dumpsters. Check frequently for leaks. Place ‰ dumpsters under roofs or cover with tarps or plastic sheeting secured around the outside of the dumpster. A plastic liner is recommended to prevent leaks. Never clean out a dumpster by hosing it down on the construction site. Place portable toilets away from storm drains. Make sure they are in ‰ good working order. Check frequently for leaks. Dispose of all wastes and demolition debris properly. Recycle ‰ materials and wastes that can be recycled, including solvents, water- based paints, vehicle fluids, broken asphalt and concrete, wood, and cleared vegetation. Dispose of liquid residues from paints, thinners, solvents, glues, and ‰ cleaning fluids as hazardous waste. Keep site free of litter (e.g. lunch items, cigarette butts). ‰ Prevent litter from uncovered loads by covering loads that are being ‰ transported to and from site. Construction Entrances and Perimeter Establish and maintain effective perimeter controls and stabilize all ‰ construction entrances and exits to sufficiently control erosion and sediment discharges from site and tracking off site. Sweep or vacuum any street tracking immediately and secure ‰ sediment source to prevent further tracking. Never hose down streets to clean up tracking. Materials & Waste Management Equipment Management & Spill Control Maintenance and Parking Designate an area of the construction site, well away ‰ from streams or storm drain inlets and fitted with appropriate BMPs, for auto and equipment parking, and storage. Perform major maintenance, repair jobs, and vehicle ‰ and equipment washing off site. If refueling or vehicle maintenance must be done ‰ onsite, work in a bermed area away from storm drains and over a drip pan or drop cloths big enough to collect fluids. Recycle or dispose of fluids as hazardous waste. If vehicle or equipment cleaning must be done onsite, ‰ clean with water only in a bermed area that will not allow rinse water to run into gutters, streets, storm drains, or surface waters. Do not clean vehicle or equipment onsite using soaps, ‰ solvents, degreasers, or steam cleaning equipment, and do not use diesel oil to lubricate equipment or parts onsite. Spill Prevention and Control Keep spill cleanup materials (e.g., rags, absorbents and ‰ cat litter) available at the construction site at all times. Maintain all vehicles and heavy equipment. Inspect ‰ frequently for and repair leaks. Use drip pans to catch leaks until repairs are made. Clean up leaks, drips and other spills immediately and ‰ dispose of cleanup materials properly. Use dry cleanup methods whenever possible ‰ (absorbent materials, cat litter and/or rags). Sweep up spilled dry materials immediately. Never ‰ attempt to “wash them away” with water, or bury them. Clean up spills on dirt areas by digging up and ‰ properly disposing of contaminated soil. Report significant spills to the appropriate local spill ‰ response agencies immediately. If the spill poses a significant hazrd to human health and safety, property or the environment, you must report it to the State Office of Emergency Services. (800) 852-7550 (24 hours). Earthmoving Grading and Earthwork Schedule grading and excavation work ‰ during dry weather. Stabilize all denuded areas, install and ‰ maintain temporary erosion controls (such as erosion control fabric or bonded fiber matrix) until vegetation is established. Remove existing vegetation only when ‰ absolutely necessary, plant temporary vegetation for erosion control on slopes or where construction is not immediately planned. Prevent sediment from migrating offsite ‰ and protect storm drain inlets, drainage courses and streams by installing and maintaining appropriate BMPs (i.e. silt fences, gravel bags, fiber rolls, temporary swales, etc.). Keep excavated soil on site and transfer it ‰ to dump trucks on site, not in the streets. Contaminated Soils If any of the following conditions are ‰ observed, test for contamination and contact the Regional Water Quality Control Board: Unusual soil conditions, discoloration, - or odor. Abandoned underground tanks. - Abandoned wells - Buried barrels, debris, or trash. - If the above conditions are observed, ‰ document any signs of potential contamination and clearly mark them so they are not distrurbed by construction activities. Landscaping Protect stockpiled landscaping materials ‰ from wind and rain by storing them under tarps all year-round. Stack bagged material on pallets and ‰ under cover. Discontinue application of any erodible ‰ landscape material within 2 days before a forecast rain event or during wet weather. Paving Avoid paving and seal coating in wet ‰ weather or when rain is forecast, to prevent materials that have not cured from contacting stormwater runoff. Cover storm drain inlets and manholes ‰ when applying seal coat, slurry seal, fog seal, or similar materials. Collect and recycle or properly dispose of ‰ excess abrasive gravel or sand. Do NOT sweep or wash it into gutters. Sawcutting & Asphalt/Concrete Removal Protect storm drain inlets during saw ‰ cutting. If saw cut slurry enters a catch basin, ‰ clean it up immediately. Shovel or vacuum saw cut slurry deposits ‰ and remove from the site. When making saw cuts, use as little water as possible. Sweep up, and properly dispose of all residues. Concrete Management Store both dry and wet materials under ‰ cover, protected from rainfall and runoff and away from storm drains or waterways. Store materials off the ground, on pallets. Protect dry materials from wind. Wash down exposed aggregate concrete ‰ only when the wash water can (1) flow onto a dirt area; (2) drain onto a bermed surface from which it can be pumped and disposed of properly; or (3) block any storm drain inlets and vacuum washwater from the gutter. If possible, sweep first. Wash out concrete equipment/trucks offsite ‰ or in a designated washout area onsite, where the water will flow into a temporary waste pit, and make sure wash water does not leach into the underlying soil. (See CASQA Construction BMP Handbook for properly designed concrete washouts.) Dewatering Discharges of groundwater or captured ‰ runoff from dewatering operations must be properly managed and disposed. When possible, send dewatering discharge to landscaped area or sanitary sewer. If discharging to the sanitary sewer, call your local wastewater treatment plant. Divert run-on water from offsite away from ‰ all disturbed areas. When dewatering, notify and obtain ‰ approval from the local municipality before discharging water to a street gutter or storm drain. Filtration or diversion through a basin, tank, or sediment trap may be required. In areas of known or suspected ‰ contamination, call your local agency to determine whether the ground water must be tested. Pumped groundwater may need to be collected and hauled off-site for treatment and proper disposal. Painting Cleanup and Removal Never clean brushes or rinse paint ‰ containers into a street, gutter, storm drain, or stream. For water-based paints, paint out brushes ‰ to the extent possible, and rinse into a drain that goes to the sanitary sewer. Never pour paint down a storm drain. For oil-based paints, paint out brushes to ‰ the extent possible and clean with thinner or solvent in a proper container. Filter and reuse thinners and solvents. Dispose of excess liquids as hazardous waste. Sweep up or collect paint chips and dust ‰ from non-hazardous dry stripping and sand blasting into plastic drop cloths and dispose of as trash. Chemical paint stripping residue and chips ‰ and dust from marine paints or paints containing lead, mercury, or tributyltin must be disposed of as hazardous waste. Lead based paint removal requires a state- certified contractor. Painting & Paint RemovalConcrete Management and Dewatering Paving/Asphalt Work Storm drain polluters may be liable for fines of up to $10,000 per day! 91 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-2.0 Shin Residence 1-12-22.pln1/28/20224:30 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 1 N.T.S. VEGETATED SWALE Scale 1/2'' = 1' - 0'' PERMEABLE PAVER EDGE DETAIL 3 N.T.S. FIBER ROLL DETAIL 4 N.T.S. 2'-0"6"1'-6"12"12"2" min.ROOT ZONE HARDENED SIDES W/ RIVER ROCK NATURAL GRASSES W/ ROCK & PEA GRAVEL NATIVE UNDISTURBED SOIL (H) # 4 T&B 80 mm THICK 'ECO-DUBLIN' BY BELGRAD®- PERMEABLE PAVERS FOR VEHICLE TRAFFIC PER MANUFACTURER'S SPEC & ICPI-49 (V) #4 @ 18" O.C. MORTAR SET PAVER BASE LAYER No 57 AGGREGARE 3/4" CRUSHED ROCK -THICKNESS PER SOIL ENGINEER'S RECOMMENDATIONJOINT (NO 8 AGGREGATE) 1"-2" BEDDING (NO 8 AGGREGATE - CRUSHED ROCK 1/4" TO 3/8" SIZE) NO SAND SUB-BASE LAYER No 2 AGGREGARE 2 1/2" CRUSHED ROCK -THICKNESS PER SOIL ENGINEER'S RECOMMENDATION NATURAL GRADE COMPACTED TO 95 % COMPACTION PROTECTIVE TREE FENCING SHALL BE SIX (6) FOOT HIGH CHAIN LINK FENCE MOUNTED ON EIGHT FOOT TALL, TWO (2) INCH DIA. GALV. POSTS, DRIVEN 24 INCHES INTO THE GROUND AND SPACED NO MORE THAN 10 FEET APART NATURAL GRADE TREE DRIPLINE DRIVEWAY WHERE OCCURS PER PLAN IF WITHIN FIVE FEET OF EDGE OF TREE,THE DRIVEWAY SHALL BE CON- STRUCTED ON TOP OF GRADE PROTECTIVE TREE FENCING 2 SEE PLAN FOR LENGTH OF GRASSY SWALE. 60" mm THICK PAVERS MAY BE USED AT PEDESTRIAN LOCATIONS NOTE: NOTE: 3/4" X 3/4" WOOD STAKES (24" MIN. LENGTH) AT 48" O.C. (TYP) SET WATTLES INTO SLOPE 2" MIN. / 4" MAX. RICE STRAW WATTLES (FIBER ROLL) 8" MIN SLOPE BANK VARIES PROVIDE 2'-0" MIN. LAP AT FIBER ROLL SPLICES PROVIDE WEEKLY INSPECTION & REINSTALL IF NECESSARY REPLACE EVERY 3 MONTHS. ACCUMULATED SILT SHALL BE REMOVED WHEN IT REACHES A DEPTH OF (6") SIX INCHES 4" max.SPACING ALONG SLOPES: 4:1 OR FLATTER = 20'-0" MAX. 4:1 - 2:1 15'-0" MAX. 2:1 OR GREATER = 10'-0" MAX Slope Varies Min.MANAGEMENT OF ACTIVITIES IN THE ROOT ZONE NOTES: 1.TREE PROTECTIVE FENCING SHALL BE INSPECTED AND APPROVED BY CITY ARBORIST PRIOR TO OBTAINING BUILDING DIVISION PERMITS. 2. NO EXCAVATION SHALL OCCUR UNDER THE TREE CANOPIES FOR INSTALLATION OF UTILITIES OR DRIVEWAY. 3. NO FILL SOIL SHALL BE PLACED ANY CLOSER THAN FIVE FEET OUTSIDE THE EDGE OF THE CANOPY OF ANY TREE ON PROPERTY. 4. UNLESS OTHERWISE APPROVED, ALL CONSTRUCTION ACTIVITIES SHALL BE CONDUCTED OUTSIDE THE DESGINATED FENCED AREA (EVEN AFTER FENCING IS REMOVED). THESE ACTIVITIES INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, THE FOLLOWING: DEMOLITION, GRADING, TRENCHING, EQUIPMENT CLENAING, STOCKPILING AND DUMPING MATERIALS (INCLUDING SOIL FILL), AND EQUIPMENT/VEHICLE OPERATION AND PARKING. 5. THE DISPOSAL OF HARMFUL PRODUCTS, INCLUDING BUT NOT LIMITED TO CHEMICALS, PAINT RINSE WATER, FUEL, CEMENT WATER RINSE, HERBICIDES, OR OTHER MATERIALS IS PROHIBITED BENEATH TREE CANOPIES OR ANYWHERE ON SITE THAT ALLOWS DRAINAGE BENEATH TREE CANOPIES. 6. THE FOLLOWING SIGNS WILL BE REQUIRED ON THE TREE PROTECTION FENCES: "TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT PRIOR APPROVAL OF CITY ARBORIST.4"SNAGESHRUBSSSCOEEEEEICVGALV.RISERE/TE/TE/TE/TE/TE/TT V E/TE/TT V T V E/TE/TT V (S 89°36'45" E 105.39')(A)(N 89°36'45" W 85.39')(A)(N 00°23'15" E 159.19')(A)MOWBANDSSSSN 00°23'15" E 139.19' WM ICVCNC WALK9"JAPANESE MAPLE 12"JAPANESE MAPLE 12"JAPANESEMAPLE11"APPLE3"PERSIMMONSNAG (PLUM)8"PLUM3"APRICOTSHRUB36"OAKFLUSHCURBSTOP SIGNCURB & GUTTER DECKC1FENCELINEPROJECT BENCHMARK MAG NAIL IN ASPHALT EL=406.34'407.56CNC407.80CNC407.61FW-RK409.17409.00MH408.24STRIPE408.01RK PTH409.04STRIPE409.07RK409.34RK407.27FC407.71CNC407.71CNC407.83FC407.38FC407.80STRIPE408.23G407.91RK PTH408.68G408.81G408.90G408.97RK408.99RK409.37RK409.07 4 TREE 408.10FC409.20STRIPE408.44G407.93G407.92G408.48WM409.17SHRUB407.58G408.49G408.49FC409.78AC409.72MH407.73FW-RK408.61RK408.61RK407.67FW-RK409.72SHRUB407.52BRK407.57FW-RK408.92FC405.83G407.18BRICK407.12CNC406.93CNC407.18BRICK407.38STRIPE406.94AC406.80AC407.16DOOR407.05BLD407.72G407.70CNC407.86DL407.71G407.76CNC407.54CNC407.09FC408.03G407.97DL407.23G407.88EO408.299 J-MPL408.536 MPL406.69FC407.78RK PTH407.49CNC-FS407.67BLD407.23CNC407.21CNC407.52FS-CNC407.58CNC407.58CNC407.91CNC407.87CNC407.38CNC406.53DWY406.86FL406.52FC406.51FC406.95EO407.6812 J-MPL406.31FC406.29FC408.04G406.49G406.24FC406.84DWY407.18DWY/EC407.40DWY/EC407.20CNC407.48CNC407.34HB407.03FL407.39BLD407.76G408.11THRESH407.17CNC407.78SILL407.56GALV RSR408.04SILL407.27DWY/BLD407.16BLD407.30DWY407.75G407.17BLD LN406.92G406.84G407.14LANDING407.30BLD407.33SILL406.32HDR406.46HDR406.37HDR406.96G407.38G406.04FC406.54DWY406.21HDR406.08HDR406.98WLK/3W405.84G406.94DWY/405.953"PERSIMMON407.10WLK/3W407.23WLK/3W406.50HB406.28BLD406.031" TREE407.06FNC406.95BRICK407.33BRICK407.07BRICK407.03BRICK407.29BRICK407.12HB407.10BLD/CNC407.44CNC407.10BLD407.05BRICK407.16BRICK407.37G407.98G408.05G408.28G407.20FNC406.33BLD406.83BRICK406.92BRICK406.22BLD407.34SILL406.46AD406.76FNC406.44HB406.17BLD406.02G405.582" TREE/5DL405.93FNC ANG406.00SNAG(PLUM)406.152" TREE405.59FNC406.34G405.40FNC405.426" TREE/5DL405.31FNC406406406 4064064064064 0 6 4 0 7 407407407407407407 40740740840840840840840840840940940940940940940940940740 7 407407407407407 6"MAPLE 5' SDE10' PUE 5' WCE 25'-71/2" 25'-0"11'-8"10'-0"10'-3" 10'-0"25'-0"25'-1"REMOVE (E) TREES HATCHED AREA INDICATES GARAGE INDICATES EXISTING RESIDENCE TO BE DEMOLISHED (N) CONCRETE SIDEWALK REMOVE (E) TREES REMOVE (E) TREE REMOVE (E) TREE REMOVE (E) TREE PROPOSED RAISED VEGGIE BOXES 5% SLOPE TO SWALE- TYP. STRAW WADDLE (TYP.) SEE DETAIL 3 / C-2.0 VEGITATED SWALE SEE DETAIL 1 / C-2.0 PROPOSED ELECTRIC METER VEGITATED SWALE SEE DETAIL 1 / C-2.0 IRREGULAR STEPPING STONES (TYP.)(E) ELECTRIC METER SERVICE ENTRANCE (N) GAS METER (E) POWER POLE (E) CURB & GUTTER TO REMAIN INDICATES (N) FENCE (N) CURB & GUTTER REMOVE UNUSED DRIVEWAY APPROACH AND REPLACE WITH VERTICAL CURB PER CITY OF SARATOGA STANDARDS INSTALL FLOWLINE TO CONCORM TO EXISTING FLOWLINE AND GRADE INSTALL NEW CURB AND GUTTER PER CITY OF SARATOGA STANDARD DETAILS SHOWN ON SHEET C-2.1(N) CURB & GUTTER REMOVE UNUSED DRIVEWAY APPROACH AND REPLACE WITH VERTICAL CURB PER CITY OF SARATOGA STANDARDS INSTALL FLOWLINE TO CONCORM TO EXISTING FLOWLINE AND GRADE INSTALL NEW CURB AND GUTTER PER CITY OF SARATOGA STANDARD DETAILS SHOWN ON SHEET C-2.1 REMOVE (E) TREE (E) GAS METER TO BE ABANDONED (E) GAS LINE TO BE ABANDONED EDGE OF PAVER DRIVEWAY SEE DETAIL 2 / C-2.0 H A M M O N S A V E N U E T H E L M A A V E N U EPORCH FF = 408.88 BALCONY 36" (E) OAK PORCH FF = 408.88 DW 407.67 BS 407.71 TS 408.88 FG 407.25 FG 407.25 TS 408.88 BS 407.71 BS 407.71 TS 408.88 PORCH FF = 408.88 FG 407.25 FG 407.25 2% FG 407.25 FG 407.25 FG 407.25 FG 407.25 FG 407.25 1% 2% GRAPHIC SCALE 2% FS = 408.00 2% FG = 407.63 E 2% 2% 2% 2% 2% 2% 2% 2% G FL∑∑RETAIN EXISTING CONCRETE DRIVEWAY DURING CONSTRUCTION FOR CONSTRUCTION ENTRANCE INSTALL NEW CONCRETE CURB & GUTTER PER CITY OF SARATOGA STANDARDS. INSTALL NEW DRIVEWAY ENTRANCE. AN ENCROACHMENT PERMIT SHALL BE SECURED AND OBTAINED FOR ALL WORK WITHIN THE RIGHT OF WAY DENOTES EXISTING DRIVEWAY TO BE REMOVED DENOTES EXISTING DRIVEWAY TO BE REMOVED∑∑∑∑∑∑ TREE #2 TREE #3 TREE #4 TREE #5 TREE #1 14 FEETRADIUS4 C-2.0 4 C-2.0 A A-6.0 A A-6.0BA-6.0BA-6.0PROPOSED AIR CONDITIONER CONDENSER LOCATION INDICATES TRASH AND RECYCLING LOCATION PROPOSED AIR CONDITIONER LOCATION DENOTES TREE PROTECTION FENCING PER DETAIL DENOTES TREE PROTECTION FENCING PER DETAIL PROPOSED ONE-STORY RESIDENCE FF = 409.00 PAD = 406.83 REQUIRED FRONT SETBACK PROPOSED FRONT SETBACK PROPOSEDINTERIOR SETBACKREQUIREDINTERIOR SETBACKREQUIRED EXTERIOR SETBACKPROPOSED EXTERIOR SETBACKPROPOSED REAR SETBACK REQUIRED REAR SETBACK GARAGE PAD = 406.67 FG 407.25 FG = 407.83'FG = 407.83' A 240 240 DESCRIPTION PROPOSED PROPERTY LINE CENTER LINE SECTION LINE EDGE OF PAVEMENT CURB AND GUTTER DRAINAGE FLOW DIRECTION FENCE (TYPE) FLOW LINE SPLASH BLOCK/ ENERGY DISSIPATOR STORM DRAIN LINE SANITARY MANHOLE STORM MANHOLE STANDARD HOODED INLET LARGE HOODED INLET FLAT GRATE INLET GRADE ELEVATION EXISTING TREE TO BE REMOVED NEW UNDERGROUND GAS LINE NEW UNDERGROUND WATER LINE NEW UNDERGROUND ELECTRIC LINE JOINT TRENCH - UNDERGROUND NEW UNDERGROUND SANITARY SEWER LINE TREE PROTECTION FENCE NEW EXISTING D.S. OVER NATURAL SURFACEOVER PAVED SURFACE FL (N) (E) TREE PROTECTION FENCING GENERAL CONSTRUCTION, GRADING AND DRAINAGE NOTES 1. PRIOR TO COMMENCEMENT OF ANY EARTHWORK/GRADING ACTIVITIES. THE PERMITEE SHALL CONTACT THE SARATOGA BUILDING DEPARTMENT AND ARRANGE A PRE-CONSTRUCTION MEETING. THE MEETING SHALL INCLLUDE THE CITY OF SARATOGA, BUILDING INSPECTOR (408) 866-1201 THE GRADING SUBCONTRACOR, GEOTECNICAL ENGINEER, AND THE GENERAL CONTRACTOR. THE PERMITEE OR A REPRESENTATIVE SHALL ARRANGE THE PRE- CONSTRUCTION MEETING AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHWORK / GRADING ACTIVITES. 2. CONTRACTOR SHALL LEAVE AN EMERGENCY PHONE NUMBER WITH THE CITY OF SARATOGA POLICE AND FIRE DEPARTMENTS. 3. CONTRACTOR SHALL POST ON THE SITE, EMERGENCY PNE NUMBERS FOR PUBLIC WORKS, ABULANCE, POLICE AND FIREDEPARTMENT. 4. CONTRACTOR SHALL NOTIFY ALL PUBLIC OR PRIVATE UTULITY OWNERS 48 HOURS PRIOR TO COMMENCEMENT OF WOTK ADJACENT TO THE UTILITY LINES, ETC. 5. THE CONTRACTOR SHALL HIRE A STREET LEANING CONTRACTOR TO CLEAN UP EXCESS SOIL AND DEBRIS FROM THE SURROUNDING STREES THAT ARE THE RESULT ON ALL GRADING OPERATIONS AND CONSTRUCTION ACTIVITIES. 6. ALL GRADING SHALL BE PERFORMED IN SUCH A MANNER AS TO COMPLY WITH THE STANDARDS ESTABLICHED BY BAAQMD. 7. ALL GRADING SHALL CONFORM TO APPROVED SPECIFICATIONS PRESENTED HEREIN OR ATTAHED HEREIN. ALL GRDING WORK SHALL BE OBSERVED AND APPROVED BY THE PROJECT’S GEOTECNICAL ENGINEER HEREIN INCLUDED IN THE CONSULTANT DIRECTORY. THE GEOTECHNICAL CONSULTANT SHALL BE APRISED OF THE START OF ALL GRADING AND EXCAVATION ACTIVITIES A MINIMUM OF 48 HOURS PRIOR TO COMMENCING WORK. 8. ALL MATERIALSREQUIRED FOR THE COMPLETE EXECUTION OF THE PROJECT SHALL BE FURNISHEDAND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED. 9. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE ANY EXISTING IMPROVEMENTS OF UNDERGROUND FACILITIES DAMAGED DURING CONSTRUCTION PERIOD. 10. THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES, FLAGMEN OR OTHER DEVICES NESSASARY TO PROVIDE FOR PUBLIC SAFTEY DURING THE CONSRUCTION PERIOD. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL ENCROACHMENT PERMITS REQUIRED TO INSTALL UTIITIES OR PERFORM ANY WORK WITHIN THE PUBLIC RIGHT OF WAY. 12. THE CONTRCTOR SHALL HAVE A SUPERINTENDANT OR REPRESENTATIVE SHALL BE ON SITE DURING ALL TIME WHEN CONSTRUCTION IS BEING PERFORMED ON SITE. 13. STORAGE OF CONSTRUCTION MATERIAL ON ANY PUBLIC STREET SHALL NOT BE PERMITTED. 14. ALL CONSTRUCTION EQUIPMENT REQUIREDE TO PERFORM GRADING OPERATIONS SHALL HAVE PROPER SOUND CONTROL MEASURES AND LIMIT UNNECESSARY IDELING. 15. CONSTRUCTION EQUIPMENT, TOOLS, ETC. SHALL NOT BE CLEANED OR RINSED INTO A STREET, GUTTER OR STORM DRAIN. SEE CONSTRUCTION OPERATION PLAN FOR LOCATION OF CLEANING FACILITY. 16. A COVERED AND CONTAINED SHALL BE POSITIONED ON SITE TO PROVIDE STORAGE OF ALL MONSTRUCTION MATERIALS THAT HAVE THE POTENTIAL OF BEING DISCHARGED INTO THE STORM DRAIN SYSTEM OR ON SITE IN ANY WAY. 17. ALL CONSTRUCTION DEBRIS SHALL BE ATHERED ON A REGULAR BASIS AND PLACED INTO A DUMPSTER WITH IS REGULARLY EMPTIED OR REMOVED ON A WEEKLY BASIS WHEN FEASIBLE. 18. CONCRETE TRUCKS AND CONCRETE FINISHING OPERATIONS SHALL NOT DISCHARGE WAH WATER INTO THE STREET GUYTTERS OR DRAINS. 19. ALL OFF-SITE CONSTRUCTION MATERIAL AND METHODS SHALL COMPLY WITH THE LATEST EXITION OF THE CITY OF SARATOGA AND THE LATEST CALTRANS STANDARD PLANS AND SPECIFICATIONS. 20. APPROVAL OF THIS PLAN APPIES OPNLY TO THE EXCAVATION, PLACEMENT AND CONPACTION OF NATURAL EARTH MATERIALS. THE APPROVAL OF THIS PLAN DOES NOT CONFER ANY RIGHTS OF ENTRY ONTO EITHER PUBLIC PROPERTY OR THE PRIVATE PROPERTY OF OTHERS. APPROVAL OF THIS PLAN DOES NOT CONSTITUE ANY APPROVAL OF EXISITNG OR PROPOSED IMPROVEMENTS THAT WOULD BE SUBJECT TO REVIEW AND APPROVAL BY THE REWPOSIBLE GOVERNING AUTHOURITY. 21. THIS PLAN DOES NOT APPROVE THE REMOVAL OR PRUNING OF ANY TREES ON OR OFF THE PROJECT’S SITE. A TREE REMOVAL PERMIT FROM THE CITY OF SARATOGA SHALL BE OPBTAINED FOR THE REMOVAL OF ANY TREE. 22. TREE PROTECTION MEASURES AS SHOWN ON THIS PLAN SHALL BE IMPLEMENTED AND INSPECTED BY THE CITY OF SARATOGA’S ARBORIST PRIOR TO COMENCEMENT OF ALL GRADING / EARTH MOVING ACTIVITIES. 23. THE CONSTRUCTION SITE SHALL BE WINTERIZED AND BEST MANAGEMENT PRACTICES SHOWN ON THE EROSION CONTROL PLAN SHALL BE IMPLEMENTED PRIOR TO COMENCEMENT OF ALL GRADING / EARTH MOVING ACTIVITIES. 24. ALL CONSTRUCTION AND GRADING ACTIVITIES SHALL BE ALLOWED DURING THE FOLLOWING HOURS: MONDAY THROUGH FRIDAY 7:30 a.m. UNTIL 6:00 p.m. SATURDAY 9:00 a.m. UNTIL 5:00 p.m. 25. THE PROJECT’S GEOTECHNICAL ENGINEER SHALL BE RETAINED TO REVIEW AND PROVIDE A LETTER OF INSPECTION AT THE COMPLETION OF ALL GRADING AND CONSTRUCTION ACTIVITIES IN ACCORDANCE TO THE PROJECT’S GEOTECHNICAL REPORT. THIS INCLUDES BUT IS NOT LIMITED TO EARTHWORK, MAT SLAB AND FOOTING EXCAVATION, RETAINING WALL EXCAVATION AND DRAINAGE, SLAB ON GRADE AND FLEXIBLE PAVING, SURFACE DRAINAGE SYSTEMS, SWIMMING POOL EXCAVATION AND SUBDRAINS. 26. THE GEOTECHNICAL ENGINEER SHALL BE GIVEN AT LEAST 7 DAYS NOTICE TO REVIEW THE PLANS AND PREPARE THE REVIEW LETTER 27. THE GEOTECHNICAL ENGINEER SHALL BE GIVEN NOTICE AT LEAST TWO WEEKS NOTICE OF THE ATICIPATED START UP DATE AND A MINIMUM OF 2 DAYS NOTICE PRIOR TO START OF ANY ASPECTS OF CONSTRUCTION THAT ARE TO BE OBSERVED. CONSTRUCTION FENCING 1. CONTRACTOR SHALL PROVIDE A CONSTRUCTION FENCE AROUND THE ENTIRE AREA OF CONSTRUCTION DISTURBANCE, INCLUDING AREAS FOR STAGING, STOPRAGE OF MATERIAL AND CONSTRUCTION OFFICE. 2. A CONSTRUCTION FENCE SHALL BE A 6 FEET TALL CHAIN LINKED WITH GREEN WIND SCREEN ON THE OUTSIDE OF THE FENCE. 3. CONSTRUCTION FENCE ADDRESSED IN THESE NOTES IS ONLY FOR VISUAL CONCORMANCE OF THE CONSTRUCTION SITE TO THE CITY OF SARATOGA STANDARDS. CONTRACTOR MAY BE REQUIRED TO PROVIDE ADDITIONAL FENCING, BARRICADES OR OTHER SAFTEY DEVICES TO KEEP THE SITE SECURE AND SAFE. GENERAL UTILITY NOTES 1. ALL TRENCHES SHALL BE BACK FILLED PER THE GEOTECHNICL REPORT OR UTILITY OWNERS STANDARDS. 2. CONTRACTOR SHALL STAKE THE LOCATIONS OF ALL ABOVE GROUND UTILITY EQUIPMENT (GAS METER, TRANSFORMER, ETC.) PLANNING DEPARTMENT MUST SPECIFICALLY AGREE WITH THE LOCATION PRIOR TO PROCEEDING WITH ANY REVISIONS TO APPROVED LOCATIONS. 3. CATHODIC PREVENTION SHALL BE REQUIRED ON ALL METALIC FITINGS AND ASSEMBLIES THAT ARE IN CONTACT WITH THE SOIL, UNLESS SPECIFICALLY DEEMED UNNECESSARY BY THE GEOOTECHNICAL ENGINEERING REPORT. CONTRACTOR SHALL BE RESPONSIBLE TO FULLY ENGINEER AND INSTALL THE SYSTEM AND COORDINATE ANODE AND TEST STATION LOCATIONS WITH THE UTILITY OWNER. 4. ALL UTILITY SYSTEMS ARE SIMPLY ILLUSTRATED IN A SCHEMATIC MANNER ON THESE PLANS. CONTRACTOR IS TO PROVIDE ALL FITTINGS, ACCESSORIES AND WORK NECESSARY TO COMPLETE THE UTILITY SYSTEM SO THAT IT IS FULLY OPERATIONAL AND FUNCTIONING FOR THE PURPOSE INTENDED. 5. UNDERGRAUND UTILITIES OR STRUCTURES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS AND EXTENT BASED UPON RECORD INFOMRATION. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE TO THE ACCURACY AND OR COMPLETENESS OF THE INFORMATION. 6. CONTRACTOR SHALL OBTAIN A PERMIT FROM WEST VALLEY SANITATION DEPARTMENT PRIOR TO OBTAINING GRADING PERMIT. CONTRACTOR SHALL VERIFY EXISTING SEWER AND STORM DRAIN INVERT ELEVATIONS PRIOR TO COMMENCEMNT OF ANY WORK. 7. EXISITNG UTILITY SHOWN ACCORDING TO THE BEST AVAILABLE INFORMATION. GAS, WATER AND SEWER SERVICE LATERALS ARE SHOWN ACCORDING TO THE BEST AVAILABLE INFORMATION. THE CONTRACTOR SHALL BERIFY THE TYPE, SIZE, LOCATION AND DEPTH OF ALL UTILITIY CROSSING (MAIN & LATERAL) ARE CORRECT AS SHOWN. CONTRACTOR SHALL EXERCIS CAUTION WHEN EXCAVATING AND SHALL PROTECT ALL EXISTING UTILITIES FROM DAMAGE DUE TO HIS OPERATION. 8. VERTICAL SEPARATION REQUIREMENTS U.N.O. SHALL BE AS NOTED BELOW: A.) A MIN. OF 6 INCHES VERTICAL CLEARANCE AS MESURED FROM OUTSIDE EDGE OF PIPE SHALL BE PROVIDED BETWEEN CROSSING UTILITY PIPES, EXCEPT A THAT THE MINIMUM VERTICAL CLEARANCE BETWEEN WATER AND SANITARY SEWER LINES SHALL BE 12 INCHES AND ALL NEW WATER PIPES SHALL BE TYPICALLY INSTALLED TO CROSS ABOVE THE SANITARY SEWER LINES. B.) WHERE NEW WATER LINES ARE REQUIRED TO CROSS UNDER EXISTING AND OR NEW SANITARY SEWER LINES, THE MIN. VERTICAL SEPARATION SHALL BE 12 INCHES. WATER LINE PIPE ENDS SHALL BE INSTALLED NO CLOSER THAN 10 FEET HORIZONTAL DISTANCE FROM CENTERLINE OF UTILITY CROSSINGS WHERE FEASIBLE. 9. HORIZONTAL SEPATATION REQUIREMENTS U.N.O. SHALL BE AS NOTED BELOW: A.) A MIN. HORIZONTAL SEPARATION DISTANCE BETWEEN NEW PIPLINES AND ANY EXISTING UTILITIES SHALL BE 5 FEET, EXCEPT THAT THE MIN. HORIZONTAL SEPARATION FOR WATER AND SANITATY SEWER MAIN LINES SHALL BE 10 FEET MIN. B.) A MIN. HORIZONTAL SEPARATION DISTANCE BETWEEN NEW PIPLINES AND JOINT TRENCE SHALL BE 5 FEET. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING APPROPRIATE UTILITIES AND REQUESTING VERIFICATION OF SERVICE POINTS, FIELD VERIFICATION OF LOCATION, SIZE, DEPTH, ETC FOR ALL THEIR FACILITIES AND TO COORDINATE WORK SCHEDULES. 11. ANY EXISTING UNDEGROUND UTILITY LINES TO BE ABANDONED SHALL BE REMOVED FROM WITHIN THE PROPOSED BUILDING ENVELOPE AND THEIR NDS CAPPED OUTSIDE OF THE BUILDING ENVELOPE 12. ANY UNDERGROUND PIPING TO BE ABANDONED IN PLACE SHALL BE FILLED WITH SOLID GROUT AND CAPPED. 13. 6 PAVEMENT SECTIONS 1. SEE GEOTECHNICAL REPORT FOR ALL FLATWORK AND VEHICULAR PAVEMENT SECTIONS AND BASE REQUIREMENTS DUST CONTROL 1. ALL EXPOSED OR DISTURBED SOILS SURFACES SHALL BE WATERED AS NECESSARYAND AS OFTEN AS DEEMED NECESSARY BY THE CLIENT/INSPECTOR OIN ORDER TO INSURE PROPER CONTROL OF BLOWING DUST FOR THE DURATION OF THE GRADING/EARTH MOVING ACTIVITIES. 2. AREA OF DIGGING AND GRADING OPERATIONS SHALL BE CONSISTENTLY WATERED TO CONTROL DUIST 3. GRADING OR OTHER DUST-PRODUCING ACTIVITIES SHALL BE SUSPENDED DURING PERIODS OF HIGH WIND WHEN DUST IS READILY VISIBLE IN THE AIR. 4. STOCKPILES OF SOIL, DEBRIS. SAND OR OTHER DUST PRODUCING MATERIALS SHALL BE WATERED OR COVERED. 5. ALL TRUCKS HAULING SOIL AND OTHER LOOSE MATERIALS SHALL BE COVERED WITH TARPAULINS OR OTHER EFFECTIVE DEVICES. 6. GRADING AND OTHER OPERATIONS THAT CRETES DUST SHALL BE STOPPED IMMEDIATELY IF DUST AFFECTS ADJACENT PROERTIES. THE CONTRCTORS SHALL PROVIDE SUFFICIENT DUST CONTROL FOR THE ENTIRE PROJECT SITE IN ACCORDANCE WITH THE PROJECT SWPPP (IF ONE EXISTS) OR AS APPLICABLE PER CITY OF SARATOGA REGULATIONS AT ALL TIMES, THE SITE SHALL BE SPRINKLERED AS NECESSARY TO PREVENT DUST NUSANCE. IN THE EVENT THAT THE CONTRCTOR NEGLECTS TO USE ADAQUATE MEASURES TO CONTROL DUST, THE CLIENT RESERVES THE RIGHT TO TAKE WHATEVER MEASURES ARE NECESSARY TO CONTROL THE DUST AND CHARGE SUCH COST TO THE CONTRACTOR. EARTHWORK QUANTITIES CUT = ______0___C.Y. MAX CUT DEPTH = ___1______FT. FILL = ______0___C.Y. MAX FILL DEPTH = ___1______FT. IMPORT ________C.Y. EXPORT ________ C.Y.∑ EARTHWORK QUANTITIES AS SHOWN ON THE PLAN IS FOR INFORMATION ONLY. GENERAL CONTRACTOR TO CALCULATE HIS/HER OWN EARTHWORK QUANTITIES FOR BIDDING PURPOSES∑ EARTHWORK REQUIRED FOR EXCATION OF FOUNDATION NOT INCLUDED PROJECT SITE GRADING & DRAINAGE PLAN 1/8" = 1'- 0" EG LEGEND 3 4 PRIOR TO THE COMMENCEMENT OF ANY EARTHWORK/ GRADING ACTIVITIES, THE PERMITEE SHALL ARRANGE A PRE-CONSTRUCTION MEETING. THE MEETING SHALL INCLUDE THE CITY OF SARATOGA GRADING INSPECTOR THE GRADING CONTRACTOR AND THE PROJECT SOILS ENGINEER. THE PERMITEE OR REPREZENTATIVE SHALL ARRANGE THE PRE-CONSTRUCTION MEETING AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHWORK/ GRADING ACTIVITIES. APPROVAL OF THIS PLAN APPLIES ONLY TO THE EXCAVATION, PLACEMENT AND COMPACTION OF NATURAL EARTH. THIS APPROVAL DOES NOT CONFER ANY RIGHT OF ENTRY TO EITHER PUBLIC PROPERTY OR THE PRIVATE PROPERTY OF OTHERS. APPROVAL OF THIS PLAN DOES NOT CONSTITUTE APPROVAL OF ANY IMPROVEMENTS. ANY PROPOSED IMPROVEMENTES ARE SUBJECT TO REVIEW AND APPROVAL BY THE RESPONSIBLE AUTHORITIES AND ALL OTHER PERMITS/ APPROVALS SHALL BE OBTAINED. IT SHALL BE THE REPONSABILITY OF THE PERMITEE TO IDENTIFY, LOCATE AND PROTECT ALL UNDERGROUND FACILITIES. THE PERMITEE SHALL MAINTAIN ALL STREETS, SIDEWALKS AND OTHER PUBLIC RIGHT OS WAYS IN A CLEAN, SAFE AND USABLE CONDITION. ALL SPILLS OF SOIL, ROCK OR CONSTRUCTION DEBRIS SHALL BE REMOVED FROM PUBLIC PROPERTY. ALL ADJACENT PROPERTY, BOTH PUBLIC AND PRIVATE, SHALL BE MAINTAINED IN A CLEAN SAFE AND USABLE CONDITION. STANDARD GRADING PLAN NOTES THIS PLAN SHALL NOT APPROVE THE REMOVAL OF ANY TREES. APPROPRIATE TREE REMOVAL PERMITS SHALL BE OBTAINED FROM THE COMMUNITY DEVELOPMENT DEPARTMENT. ANY REQUIRED TREE PROTECTION MEASURES SHALL BE MAINTAINED THROUGHOUT CONSTRUCTION. ALL GRADING AND EARTHWORK ACTIVITIES SHALL CONFORM TO THE APPROVED PLANS AND SPECIFICATIONS. ALL GRADING AND EARTHWORK ACTIVITIES SHALL BE OBSERVED AND APPROVED BY THE SOILS ENGINEER. THE SOILS ENGINEER SHALL BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY GRADING OR EARTHWORK ACTIVITIES. UNOBSERVED OR UNAPPROVED WORK SHALL BE REMOVED AND REPLACED UNDER OBSERVATION OF THE PROJECT SOILS ENGINEER. EROSION CONTROL MEASURES & BEST MANAGEMENT PRACTICES SHALL BE INSTALLED AND MANAGED FOR THE ENTIRE SITE AND REQUIRED YEAR-ROUND. 8 7 6 NOTES ALL GRADING AND EARTHWORK ACTIVITIES SHALL BE PERFORMED IN SUCH A MANNER AS TO COMPLY WITH STANDARDS STABLISHED BY THE BAY AREA QUALITY MANAGEMENT DISTRICT FOR AIRBORNE PARTICULES. 5 ALL ROOF RAINWATER LEADERS ARE TO BE DISCHARGED ONTO SPLASH BLOCKS, WHICH ARE DESIGNED TO SPREAD OUT THE RAIN WATER SO THAT IT ENTERS THE LANDSCAPED AREAS AS SHEET FLOW. BEYOND 3 FEET FROM THE EDGE OF THE PROPOSED FOUNDATION VICINITY MAPDETAILS 1 2 EROSION CONTROL NOTES∑ALL COMPACTED & FINISHED GRADES SHOULD BE SLOPED AT A MINIMUM OF 2% GRADIENT AWAY FROM EXTERIOR FOUNDATIONS FOR A DISTANCE OF 3 FEET.∑∑STORM WATER RETENTION NOTE: DISPOSTION AND TREATMENT OF STORM WATER WILL COMPLY WITH THE NATIONAL POLLUTION DISCHARDE ELIMINATION SYSTEM STANDARDS AND IMPLEMENTATION STANDARDS ESABLISHED BY THE SANTA CLARA VALLEY URBAN RUNOFF POLLUTION PREVENTION PROGRAM. A TRASH CONTAINER SHALL BE MAINTAINED ON SITE AT ALL TIMES AND DEBRIS ON SITE WHICH SCOULD OTHERWISE BLOW AWAY, SHALL BE REGULARLY COLLECTED AND PLACED IN CONTAINER ALL NEW/ UPGRADED UTILITIES SHALL BE INSTALLED UNDERGROUND ALL CONSTRUCTION DEBRIS (WOOOD SCRAPS AND OTHER DEBRIS, WHICH CANNOT BLOW AWAY) SHALL BE PILED WITHIN THE PROPERTY LINE OF THE PROJECT IN A NEAT AND SAFE MANNER.∑THE PROJECT SHALL HAVE SIGNAGE VIEWABLE FROM THE PUBLIC STREET THAT INDICATES THE HOURS OF CONSTRUCTION AS MON - FRI FROM 7:30 AM TO 6 PM, SATURDAYS FROM 9 AM TO 5 PM∑APPLICANT OWNER SHALL MAINTAIN THE STREETS, SIDEWALKS AND OTHER PUBLIC RIGHT OF WAY IN A CLEAN, SAE AND USEABLE CONDITION. ALL SPILLS OF SOIL, ROCK OR CONSTRUCTION DEBRIS SHALL BE REMOVED FROM THE PUBLIC PROPETY. ALL ADJACENT PROPERTY, BOTH PUBLIC AND PRIVATE, SHALL BE MAINTAINED IN A CLEAN, SAFE AND USABLE CONDITION.∑PRIOR TO FOUNDATION INSPECTION BY THE CITY, THE LICENSED LAND SURVEYOR OF RECORD SHALL PROVIDE A WRITTEN CERTIFICATION THAT ALL BUILDING SETBACKS ARE PER THE APPROVED PLANS.∑DAMAGES TO DRIVEWAY APPROACH, CURB AND GUTTER, PUBLIC STREETS, OR OTHER PUBLIC IMPROVEMENTS DURNING CONSTRUCTION SHALL BE REPAIRED PRIOR TO FINAL INSPECTION.∑PRIOR TO BUILDING DEPARTMENT FINAL, ALL DRAINAGE, GRADING AND LANDSCAPING OF THE SITE SHALL BE COMPLETED.∑N1 1 EXCAVATION WITHIN BUILDING FOOTPRINT REQUIRED FOR BUILDING CRAWLSPACE IS EXCLUDED FROM EARTHWORK QUANTITIES∑92 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-2.1 Shin Residence 1-12-22.pln1/28/20224:30 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 DETAILS 93 94 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.0 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 THELMA AVE. 2026220280 20298 20261 2026920297 13499 13368 13379 20240 20220 20202 13514 20221 20201 13496 1349 5 HAMMONS AVE.THELMA AVE.HAMMONS AVE.NTS STREET PROFILES STREET PROFILE 'A' STREET PROFILE 'B' 13496 HAMMONS AVE. 13499 HAMMONS AVE. 20240 THELMA AVE. 20220 THELMA AVE. 20202 THELMA AVE. 20201 THELMA AVE. 20221 THELMA AVE. 20261 THELMA AVE. 20269 THELMA AVE. 20262 THELMA AVE. 20280 THELMA AVE. EG NEIGHBORHOOD PROFILE: MANY OF THE HOMES IN THIS NEIGHBORHOOD CAN BE CHARACTERISED AS RECENTLY REMOVATED OR CONTEMPORARY. MOST OF THE HOMES USE STUCCO AS AN EXTERIOR FINISH AND HAVE 10' HIGH EXTERIOR WALLS. THE PROPOSED HOUSE FEATURES THESE DESIGN ELEMENTS AS WELL. 95 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.1 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 20221 THELMA AVE.13514 HAMMONS AVE. HAMMONS AVENUE 13514 HAMMONS AVE.13496 HAMMONS AVE. THELMA AVENUE STREETSCAPE ELEVATONS NTS CTS STREET PROFILE 'A' SCALE: 1/16" = 1'-0" STREET PROFILE 'B' SCALE: 1/16" = 1'-0" 96 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.2 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 206914"SNAGEESHRUBSSSCOEEEEEICVGALV.RISERE/TE/TE/TE/TE/TE/TT V E/TE/TT V T V E/TE/TT V (S 89°36'45" E 105.39')(A)(N 89°36'45" W 85.39')(A)(N 00°23'15" E 159.19')(A)MOWBANDSSSSN 00°23'15" E 139.19'ICVCNC WALK4"TREE9"JAPANESE MAPLE 6"MAPLE12"JAPANESEMAPLE12"JAPANESEMAPLE11"APPLE3"PERSIMMONSNAG (PLUM)8"PLUM3"APRICOTSHRUB36"OAKFLUSHCURBSTOP SIGNCURB &GUTTERDECKJOINTPOLEC1FENCELINEPROJECTBENCHMARKMAG NAIL INASPHALTEL=406.34'407.56CNC407.80CNC407.61FW-RK409.17MH409.00MH408.24STRIPE408.01RK PTH409.04STRIPE409.07RK409.34RK407.27FC407.71CNC407.71CNC407.83FC407.38FC407.80STRIPE408.23G407.91RK PTH408.68G408.81G408.90G408.97RK408.99RK409.37RK409.074 TREE408.10FC409.20STRIPE408.44G407.93G407.92G408.48WM409.17SHRUB407.58G408.49G408.49FC409.78AC409.72MH407.73FW-RK408.61RK408.61RK407.67FW-RK409.72SHRUB407.52BRK407.57FW-RK408.92FC405.83G407.18BRICK407.12CNC406.93CNC407.18BRICK407.38STRIPE406.94AC406.80AC407.16DOOR407.05BLD407.72G407.70CNC407.86DL407.71G407.54CNC407.09FC408.03G407.97DL407.23G407.88EO408.299 J-MPL408.536 MPL406.69FC407.78RK PTH407.49CNC-FS407.67BLD407.23CNC407.21CNC407.52FS-CNC407.58CNC407.58CNC407.91CNC407.87CNC407.38CNC406.53DWY406.86FL406.52FC406.51FC406.95EO407.6812 J-MPL406.31FC406.29FC408.04G406.49G406.24FC406.84DWY407.18DWY/EC407.20CNC407.34HB407.03FL407.39BLD407.76G408.11THRESH407.17CNC407.78SILL407.56GALV RSR408.04SILL407.27DWY/BLD407.16BLD407.30DWY407.75G407.17BLD LN406.92G406.84G407.14LANDING407.30BLD407.33SILL406.32HDR406.46HDR406.37HDR406.96G407.38G406.04FC406.54DWY406.21HDR406.08HDR406.98WLK/3W405.84G406.94DWY/405.953"PERSIMMON407.10WLK/3W407.23WLK/3W406.50HB406.28BLD406.031" TREE407.06FNC406.95BRICK407.33BRICK407.07BRICK407.03BRICK407.29BRICK407.12HB407.10BLD/CNC407.44CNC407.10BLD407.16BRICK407.37G407.98G408.05G408.28G407.20FNC406.33BLD406.83BRICK406.92BRICK406.22BLD407.34SILL406.46AD406.76FNC406.44HB406.17BLD406.02G405.582" TREE/5DL405.93FNC ANG406.00SNAG(PLUM)406.152" TREE405.59FNC406.34G405.40FNC405.426" TREE/5DL405.31FNC405406406406 4064064064064 0 6 4 0 7 407407407407407 4074074084084084084084084094094094094094 0 9 40940940940740 7 407407407407407 WM 25'-0" 24'-41/2"11'-8"10'-0"10'-3" 10'-0"25'-0"25'-1"5'-0" 10'-0"5'-0"3'-0"REMOVE (E) TREES HATCHED AREA INDICATES GARAGE INDICATES EXISTING RESIDENCE TO BE DEMOLISHED (N) CONCRETE SIDEWALK REMOVE (E) TREE REMOVE (E) TREES REMOVE (E) 6" MAPLE TREE REMOVE (E) TREE REMOVE (E) TREES INDICATES TRASH AND RECYCLING LOCATION PROPOSED RAISED VEGGIE BOXES INDICATES (E) LOWEST ELEVATION POINT @ BUILDING'S EDGE: 405.90' INDICATES (E) HIGHEST ELEVATION POINT @ BUILDING'S EDGE: 407.80' INDICATES PROPOSED 6' HIGH WOOD FENCE INDICATES EXISTING FENCE TO BE REMOVED 10' P.U.E. 5' W.C.E 5' S.D.E INDICATES PORTION OF PROPOSED 6' HIGH WOOD FENCE W/ GATE INDICATES PORTION OF PROPOSED 6' HIGH WOOD FENCE W/ GATE (E) GAS METER TO BE ABANDONED (N) GAS METER (E) GAS LINE TO BE ABANDONED EXISTING NATURAL GRADE (TO BE UNDISTURBED 8" x 8" x 16" C.M.U. WALL WITH STUCCO FINISH (TYP.) 12" DIAMETER CONCRETE PIERS SPACED AT 6 FEET O.C. FOR SUPPORT OF WALL (TYP.) H A M M O N S A V E N U E T H E L M A A V E N U EPORCH FF = 408.88 BALCONY 36" (E) NEIGHBOR OAK PORCH FF = 408.88 PORCH FF = 408.88 1% 40 GRAPHIC SCALE 10 50 2010 ( IN FEET ) 1 inch = 8 ft. NEIGHBORING RESIDENCE 13496 NEIGHBORING RESIDENCE 20221 E G TREE #2 TREE #3 TREE #4 TREE #5 TREE #1 4 C-2.0 4 C-2.0 GARDEN WALL DETAIL1 A-1.2 1 A-1.2 Just-Us Department A A-5.0 A A-5.0BA-5.0BA-5.0PROPOSED AIR CONDITIONER CONDENSER UNITS (2) DENOTES TREE PROTECTION FENCING PER DETAIL DENOTES TREE PROTECTION FENCING PER DETAIL407.76CNC407.40DWY/EC407.48CNC407.05BRICK407408409REQUIRED FRONT SETBACK PROPOSED FRONT SETBACK PROPOSEDINTERIOR SETBACKREQUIREDINTERIOR SETBACKREQUIRED EXTERIOR SETBACKPROPOSED EXTERIOR SETBACKPROPOSED REAR SETBACK REQUIRED REAR SETBACK GARAGE FF = 408.42 FF = 406.67 PROPOSED ONE-STORY RESIDENCE FF = 409.00 PAD = 406.83 407 SITE PLAN LEGEND PROPERTY LINE SETBACK LINE (E) GRADE MINOR CONTOUR LINE (E) GRADE MAJOR CONTOUR LINE EXISTING FENCE TO REMAIN EXISTING FENCE TO BE REMOVED NEW GAS LINE NEW WATER LINE EXISTING OVERHEAD LINE NEW JOINT TRENCH INDICATES MAILBOX INDICATES JOINT SERVICES POLE INDICATES FINISH FLOOR INDICATES MANHOLE INDICATES WATER METER INDICATES GAS METER INDICATES ELECTRIC METER PROPOSED RESIDENCE PROPOSED LANDSCAPED AREAS FF MB JP WM GM EM MH EXISTING TREE TO REMAIN EXISTING TREE TO BE REMOVED TREE PROTECTION FENCING 151 PROPOSED SITE PLAN 1/8" = 1'- 0" TJS SITE NOTES STORM WATER RETENTION NOTE- DISPOSITION AND TREATMENT OF STORM WATER WILL COMPLY WITH THE NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM ("NPDES") STANDARDS AND IMPLEMENTATION STANDARDS ESTABLISHED BY THE SANTA CLARA VALLEY URBAN RUNOFF POLLUTION PREVENTION PROGRAM. SETBACK VERIFICATION NOTE- PRIOR TO FOUNDATION INSPECTION BY THE CITY, THE LLS OF RECORD SHALL PROVIDE A WRITTEN CERTIFICATION THAT ALL BUILDING SETBACKS ARE PER THE APPROVED PLANS.EGN 97 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.3 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691N10'-0" 5'-0"5'-0"REMOVE (E) TREES REMOVE (E) TREE REMOVE (E) TREES REMOVE (E) TREE REMOVE (E) TREE REMOVE (E) TREE REMOVE (E) BRICK (E) LANDING TO BE REMOVED (E) LANDING TO BE REMOVED (E) HARDSCAPE TO BE REMOVED (E) DECK TO BE REMOVED (E) FENCE TO BE REMOVED (E) HARDSCAPE TO BE REMOVED (E) NEIGHBOR'S TREE TO REMAIN (TYP.) EXISTING BUILDING OUTLINE ON ADJACENT LOT, TYP. EXISTING BUILDING OUTLINE ON ADJACENT LOT, TYP. 10' P.U.E. 5' W.C.E 5' S.D.E (E) CURBCUT AND DRIVEWAY APPROACH TO BE REMOVED (E) CURBCUT AND DRIVEWAY APPROACH TO BE REMOVED (E) GAS METER TO BE REMOVED EEEEEEEE/TE/TE/TE/TE/TE/TT V E/TE/TT V T V E/TE/TT V OHOHOHOHOHOHOHOHOHOHOHOHOHOHOHOHOH (S 89°36'45" E 105.39')(A)(N 89°36'45" W 85.39')(A)(N 00°23'15" E 159.19')(A)SSSSN 00°23'15" E 139.19' 4"TREE 9"JAPANESE MAPLE 12" JAPANESE MAPLE DECK LANDING 405406406406 4064064064064 0 6 4 0 7 407407407407407407 4074074084084084084084084084094094094094094 0 9 40940940940940740 7 407407407407407 LANDING NEIGHBORING RESIDENCE 13496 NEIGHBORING RESIDENCE 20221 12" JAPANESE MAPLE H A M M O N S A V E N U E T H E L M A A V E N U E40 GRAPHIC SCALE 10 50 2010 ( IN FEET ) 1 inch = 8 ft. EXISTING RESIDENCE TO BE REMOVED 8" PLUM 3" APRICOT SNAG (PLUM) 3" PERSIMMON 11" APPLE CONCRETE CONCRETE CONCRETE 1/8" = 1'- 0" EG DEMOLITION SITE PLAN 98 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-2.0 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 16'-5"10'-0"11'-1/2"5'-11"18'-1"15'-11"32'-61/2"13'-5" 123'-4"68'-8"123'-4"68'-8"2'-0"2'-0"33'-31/2"1'-11"24'-0"2'-6"2'-111/2"12'-6"2'-51/2"5'-11"7'-0"7'-61/2"EQ.EQ.EQ.EQ.EQ.EQ.5'-4"EQ.5'-4"EQ. 4'-8"EQ.4'-8"EQ.8'-21/2"EQ.EQ. 16'-6"2'-7"3'-6"3'-41/2"9'-61/2"EQ.EQ.3'-11"8'-21/2"12'-0"3'-11"1'-1/2"9'-0"1'-6"9'-0"1'-6"9'-0"1'-6"2'-0"6'-0"2'-0"54'-8"12'-21/2"1'-91/2"10'-71/2"11'-101/2"2'-51/2"13'-5"16'-31/2"31'-101/2"7'-111/2" 12'-111/2"18'-11"5'-0"8'-0"33'-0" 11'-1/2"5'-51/2"21'-0"46'-0" 20'-1/2"16'-5"27'-101/2"4'-0"5'-91/2"11'-21/2"EQ.EQ.5'-51/2"2'-0"14'-8"3'-0"9'-111/2"2'-51/2"5'-0"7'-11"12'-3"4'-3"6'-0"14'-11"5'-10"4'-8"3'-111/2"10'-1/2"6'-6"7'-51/2"11'-111/2"4'-51/2"12'-0"2'-111/2"6'-51/2"15'-11"19'-41/2"5'-0"2'-61/2"7'-61/2"8'-8" A 5.0 A 5.0 B 5.0 B 5.0 LIVING ROOM CEILING HEIGHT 14'-10" MAX. FOYER DINING ROOM FAMILY ROOM KITCHEN MUD ROOM BATH 3 GUEST BEDROOM DINING NOOK OFFICE BEDROOM 3 BEDROOM 2 BATH 2 WALK-IN CLOSET MASTER BATH MASTER BEDROOM COVERED PORCH COVERED VERANDA GARAGE STORAGELIN. LIN. PDR. RM. LAUNDRY FP BUTLER'S PANTRY SHOWER UTILITIES PANTRY PORCH BALCONY REF. CL CLCLCL 26562656265648303056305648604060 76910 1926 4060 4060 4060 3056604026462646 6056 4056 HEAT & GLOW - TRUE 42" DIRECT VENT GAS FIREPLACE 24306056Main Floor Plan = 4,206 sf NPROPOSED FLOOR PLAN 1/4" = 1'- 0" EG 99 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-3.0 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 20691 NA 5.0 A 5.0 B 5.0 B 5.0 DENOTES P.V. SOLAR PANELS DS DS DS DS DS DS DSDS DS 10':12' SLOPE 10':12'SLOPE10':12' SLOPE 10':12'SLOPE10':12'SLOPE10':12'SLOPE12':12' SLOPE 12':12' SLOPE 12':12' SLOPE 12':12' SLOPE 10':12'SLOPE10':12'SLOPE10':12'SLOPE12':12' SLOPE 12':12' SLOPE12':12' SLOPE 12':12' SLOPE 10':12'SLOPE10':12'SLOPE10':12' SLOPE DSDS DS DS10':12' SLOPE PROPOSED ROOF PLAN 1/4" = 1'-0" EG 100 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-4.0 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 2069118'-0"26'-0"T.P. = 417.33' (+8'-9") F.F. = 407.33' (-1'-3") F.F. = 408.58' (±0'-0") T.P. = 418.58' (+10'-0") MAX HEIGHT LIMIT = 432.85' AVERAGE HEIGHT = 406.85' INDICATES PROPOSED GRADE INDICATES NATURAL GRADE AVERAGE HEIGHT 406.85' DENOTES ROOF HEIGHT FROM PREVIOUS PLANS'MAXIMUM PROPOSED HEIGHT18' ABOVE AVERAGE GRADE LINE4'-11"2'-11" 1 1 2 3 6 6 1 23'-3"3'-10"2'-3"26'-0"18'-0"F.F. = 408.58' (±0'-0") T.P. = 418.58' (+10'-0") AVERAGE HEIGHT = 406.85' MAX HEIGHT LIMIT = 432.85' (+23'-10") INDICATES PROPOSED GRADEINDICATES NATURAL GRADE DENOTES ROOF HEIGHT FROM PREVIOUS PLANS'MAXIMUM PROPOSED HEIGHT18' ABOVE AVERAGE GRADE LINE5'-1"3'-10" 1 2 6 3 WOOD - WALNUT DARK STAIN4 2 5 3 1 6 ALUMINUM CLAD,'HAMPTON SAGE' ANODIZED ALUMINUM EXTERIOR FINISHES ASPHALT COMPOSITION ROOFING - CERTAINTEED PRESIDENTIAL TL - COUNTY GREY STUCCO PLASTER - 'BEACHSIDE VILLA' COLOR LRV47 ROOF: EXTERIOR WALLS: EXTERIOR WALLS: DOOR: GARAGE DOOR: WINDOWS & EXTERIOR DOORS: STONE VENEER - MCGREGOR LAKE TUMBLED - MONTANA ROCKWORKS WOOD 'CARRIAGE' DOOR -'HAMPTON SAGE' COLOR EXTERIOR ELEVATIONS 1/4" = 1'-0" SOUTH ELEVATION EAST ELEVATION EAST ELEVATION SOUTH ELEVATION EG TS 101 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-4.1 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 2069118'-0"26'-0"INDICATES PROPOSED GRADE INDICATES NATURAL GRADE F.F. = 408.58' (±0'-0") T.P. = 418.58' (+10'-0") AVERAGE HEIGHT = 406.85' MAX HEIGHT LIMIT = 432.85' F.F. = 407.33' (-1'-3") T.P. = 417.33' (+8'-9") DENOTES ROOF HEIGHT FROM PREVIOUS PLANS'MAXIMUM PROPOSED HEIGHT18' ABOVE AVERAGE GRADE LINE3'-10"4'-3" 1 2 3 6 1 WOOD - WALNUT DARK STAIN4 2 5 3 1 6 ALUMINUM CLAD,'HAMPTON SAGE' ANODIZED ALUMINUM EXTERIOR FINISHES ASPHALT COMPOSITION ROOFING - CERTAINTEED PRESIDENTIAL TL - COUNTY GREY STUCCO PLASTER - 'BEACHSIDE VILLA' COLOR LRV47 ROOF: EXTERIOR WALLS: EXTERIOR WALLS: DOOR: GARAGE DOOR: WINDOWS & EXTERIOR DOORS: STONE VENEER - MCGREGOR LAKE TUMBLED - MONTANA ROCKWORKS WOOD 'CARRIAGE' DOOR -'HAMPTON SAGE' COLOR17'-7"26'-0"T.P. = 417.33' (+8'-9") F.F. = 408.58' (±0'-0") F.F. = 407.33' (-1'-3") F.F. = 408.58' (±0'-0") T.P. = 418.58' (+10'-0") MAX HEIGHT = 432.85' AVERAGE HEIGHT = 406.85' INDICATES PROPOSED GRADEINDICATES NATURAL GRADEAVERAGE HEIGHT 406.85' DENOTES ROOF HEIGHT FROM PREVIOUS PLANS'MAXIMUM ALLOWED HEIGHT18' ABOVE AVERAGE GRADE LINE4'-11"2'-11"3'-3"3'-10"2'-3" 1 1 1 2 3 4 5 6 1/4" = 1'-0" WEST ELEVATION NORTH ELEVATION NORTH ELEVATION EXTERIOR ELEVATIONS WEST ELEVATION EG TS 102 13514 HAMMONS AVE. SARATOGA, CA 95070 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-5.0 Shin Residence 1-12-22.pln1/28/20224:31 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone www.metroarchitects.com SHEET NUMBER SHIN RESIDENCE CHECKED BY : ARCHITECT :TOM SLOAN PROJECT NAME 1/28/2022 2069110'-6"10'-0"26'-0"9'-10"2'-0"T.P. = 417.08' (+8'-6") F.F. = 408.58' (±0'-0") F.F. = 407.67' (-1'-4") T.P. = 418.58' (+10'-0") F.F. = 408.58' (±0'-0") T.P. = 418.58' (+10'-0") HIGHEST ELEVATION POINT AT BUILDING FOOTPRINT 407.80'LOWEST ELEVATION POINT AT BUILDING FOOTPRINT 405.90' INDICATES PROPOSED GRADE INDICATES NATURAL GRADEAVERAGE HEIGHT 406.85' MAX HEIGHT LIMIT = 432.85' AVERAGE HEIGHT = 406.85' (E) 406.25 (P) 406.25(E) 407.66 (P) 406.80 MAXIMUM PROPOSED HEIGHTOFFICE HALLWAY FOYER DINING ROOM FAMILY ROOM GUEST BEDROOM STORAGE GARAGE ATTIC ATTIC ATTIC ATTIC C B2'-0"10'-0"26'-0"F.F. = 408.58' (±0'-0") T.P. = 418.58' (+10'-0") AVERAGE HEIGHT = 406.85' MAX HEIGHT LIMIT = 432.85' INDICATES PROPOSED GRADE INDICATES NATURAL GRADE (E) 407.30 (P) 407.30 (E) 407.25 (P) 407.25 MAXIMUM PROPOSED HEIGHTGUEST BEDROOMHALLBATHROOM 3 ATTIC 1/4" = 1'-0" PROPOSED SECTIONS SECTION 'A' SECTION 'B' SECTION 'C' SECTION B-B SECTION A-A EG TS A-A B-B 103 104 105 106 107 REPORT TO THE PLANNING COMMISSION Meeting Date: February 9, 2022 Application: PDR21-0018/ARB21-0067 Address/APN: 14780 Montalvo Road/517-20-033 Property Owner: Fan Yang & Zhifen Xu From: Debbie Pedro, Community Development Director Report Prepared By: Nicole Johnson, Senior Planner 108 Report to the Planning Commission 14780 Montalvo Road– Application # PDR21-0018/ARB21-0067 February 9, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a 223 square foot single story addition and a 1,404 square foot second story addition (maximum height 26’) which includes an ADU, to an existing single-story residence. Two protected trees are proposed for removal. STAFF RECOMMENDATION Adopt Resolution No. 22-004 approving the project subject to conditions of approval included in Attachment 1. Pursuant to City Code Section 15-45.060(a)(2), approval by the Planning Commission is required as the project includes the conversion of a single story structure to a multi-story structure. PROJECT DATA Gross/Net Site Area: 20,172 sq. ft. gross/net (.46 acres) Average Site Slope: 7.5% General Plan Designation: RLD (Residential Low Density) Zoning: R-1-20,000 (Single Family Residential) Existing Proposed Allowed/Required Site Coverage Residence w/Garage Driveway Walkways/Patios/Pond/Gazebo Total Proposed 4,052 sq. ft. 513 sq. ft. 2,649 sq. ft. 7,214 sq. ft. (36%) 4,940 sq. ft. 513 sq. ft. 2,872 sq. ft. 8,325 sq. ft. (41%) 9,984 sq. ft. (49%) * Floor Area Residence Garage ADU Total Floor Area 3,587 sq. ft. 465 sq. ft. 0 sq. ft. 4,052 sq. ft. 4,046 sq. ft. 465 sq. ft. 1,199 sq. ft. 5,710 sq. ft.** 4,970 sq. ft.* plus up to 800 sq. ft. over allowable for ADU** Height 19’10” 26’ 26’ Setbacks Front: Left Side: Right Side Rear: 1st Floor 30’ 30’3”’ 14’3”*** 36’9” 1st Floor 2nd Floor 30’ 39’9” 16’10” 61’1” 14’3” *** 21’10”’ 36’9” 46’10” 1st Floor 2nd Floor 30’ 30’ 15’ 20’ 15’ 20’ 35’ 45’ Grading - No Grading Proposed No grading limit in the R-1-20,000 zoning district *Includes onetime 10% for deed restricted ADU Per City Code Section 15-56.025 (2) ** Includes onetime 800 sq.ft. allowance for ADU Per City code Section 15-56.025 (5) (b) ***Existing legal non-conforming setback 109 Report to the Planning Commission 14780 Montalvo Road– Application # PDR21-0018/ARB21-0067 February 9, 2022 Page | 3 SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The project site is located at 14780 Montalvo Road in the R-1-20,000 (Single Family Residential) zoning district. The 20,172 square foot site is relatively level. Surrounding uses on all sides include one-story single-family homes on similar sized parcels. Project Description The architectural style of the project can best be described as modern. The existing single story residence consists of 3,587 square feet with a 465 square foot garage. The project consists of a 223 square foot addition adjacent to the existing living room for a new bedroom as well as a 1,404 square foot new second floor that includes a deed restricted two bedroom ADU and loft area. The project also includes an interior remodel and exterior renovation. The new ADU will have access from exterior stairs in the rear yard as well as interior stairs in the foyer of the house. A new uncovered second story deck is proposed which is accessed from the loft area. The deck is located above the front porch facing the right of way. The applicant has provided a color and materials board. (Attachment 5). Below is a list of the proposed exterior materials. Detail Colors/Materials Exterior Alabaster/Stucco Windows / Trim Bronze/Vinyl Front door/Garage door Bronze Roof Gray Black/Slate Tile Trees The project arborist inventoried a total of six protected trees on the property. The City Arborist has made the findings to remove two protected trees along the front of the residence, a 10” persimmon and 10” Saratoga sweet bay, as they are in conflict with the design of the project. A description of the trees to be preserved and the tree protection plan are included in the Arborist Report. (Attachment 2) Landscaping The installation of front yard landscaping is required prior to building permit final inspection. The project includes a condition of approval that landscaping is to be installed per City Code Section 15- 12.095. FINDINGS Design Review The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. 110 Report to the Planning Commission 14780 Montalvo Road– Application # PDR21-0018/ARB21-0067 February 9, 2022 Page | 4 a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the building site is relatively level and no grading is required to construct the project. The site development is appropriate to the site’s natural constraints with single family homes around it. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the City Arborist has made the findings to remove two protected trees. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that no community view sheds are in the vicinity of the project. d. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the proposed second story addition complies with the maximum height limitation of 26 feet allowable for residential structures; the building has varying architectural forms and exterior materials to break up the appearance of mass, the building setbacks comply with those required for the R-1-20,000 zoning district. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood and streetscape. This finding may be made in the affirmative in that the project includes a condition of approval that front yard landscaping is to be installed prior to building department final inspection. Staff will ensure that this landscaping is complimentary to the neighborhood and streetscape. The City Code requires that at least 50% of the front setback area be landscaped. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding may be made in the affirmative in that the home is similar in mass and height with the homes in the neighborhood and will not cast shadows on the adjacent properties which could impair the adjacent property owner’s opportunity to utilize solar energy. 111 Report to the Planning Commission 14780 Montalvo Road– Application # PDR21-0018/ARB21-0067 February 9, 2022 Page | 5 g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk and avoiding unreasonable interference with privacy and views as detailed in the findings above. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. Neighbor Notification and Correspondence The Community Development Department mailed public notices to property owners within 500 feet of the site. In addition, the public hearing notice and description of the project was published in the Saratoga News. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single-family residence and small structures in a residential area. The project, as proposed, is for the construction of a new addition to an existing residence in a suburban, residential area. ATTACHMENTS 1. Resolution No. 22-004 2. Arborist Report dated 09/02/2021 3. Neighbor Notification Forms 4. Story Pole Certification 5. Materials Board 6. Project Plans 112 RESOLUTION NO: 22-004 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0018 AND ARBORIST REVIEW ARB21-0067 14780 MONTALVO ROAD (APN 517-20-033) WHEREAS, on June 15, 2021 an application was submitted by Fan Yang & Zhifen Xu requesting Design Review approval to construct a 223 square foot single story addition and a 1,404 square foot second story addition (maximum height 26’) which includes an ADU, to an existing single-story residence. Two protected trees are proposed for removal. The site is located within the R-1-20,000 zoning district. WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA) and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on February 9, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints; the porch and entry are in scale with other structures in the neighborhood. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. 113 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 2 Section 5: The City of Saratoga Planning Commission hereby approves PDR21- 0018/ARB21-0067 for 14780 Montalvo Road (APN 517-20-033), subject to the Findings and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 9th day of February 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Anjali Kausar Chair, Planning Commission 114 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0018/ARB21-0067 14780 MONTALVO ROAD (517-20-033) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. 115 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 4 In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. COMMUNITY DEVELOPMENT DEPARTMENT 5. PERMANENT CONDITION OF APPROVAL (Deed Restriction) The owner shall record a deed restriction satisfactory to the Community Development Director restricting the rental of the accessory dwelling unit to only households that qualify as low, very-low, or extremely-low income households as those terms are defined in the most recent Santa Clara County Housing and Urban Development Program Income Limits. In the event that the most recent such report is more than five years old, the rental income limits of the accessory dwelling unit shall be in accordance with the definitions set forth in Health and Safety Code section 50079.5, 50105, and 50106 as those sections exist as of the effective date of this restriction. “Rental” means any agreement whereby the occupant(s) of the accessory dwelling unit make any payment in consideration of said occupancy. 6. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Development Plans. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 7. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut-off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 8. In order to comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 9. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. 116 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 5 f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 10. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 11. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency, and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall consider potential damage to roots of protected trees 12. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 13. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 14. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. FIRE DEPARTMENT 15. The owner/applicant shall comply with all Fire Department requirements. ARBORIST 16. The owner/applicant shall comply with all City Arborist requirements. 117 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 6 PUBLIC WORKS/ENGINEERING 17. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 18. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 19. Per Design Review PDR21-0018, no improvements in the public right-of-way are required. 20. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 21. Applicant / Owner shall maintain the streets, sidewalks and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 22. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g. landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay-Friendly Landscaping). 23. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing storm water pollution: • Owner shall implement construction site inspection and control to prevent construction site discharges of pollutants into the storm drains per approved Erosion Control Plan. • The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non-storm water management through all phases of construction (including, but not limited to, site grading, building, and finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. • City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 118 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 7 24. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. BUILDING DEPARTMENT SUBMITTAL 25. Complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. Arborist report dated September 2, 2021. c. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. d. This signed and dated Resolution printed onto separate construction plan pages. 119 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 8 DESIGN REVIEW FINDINGS PDR21-0018/ARB21-0067 14780 MONTALVO ROAD (517-20-033) The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the building site is relatively level and no grading is required to construct the project. The site development is appropriate to the site’s natural constraints with single family homes around it. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the City Arborist has made the findings to remove two protected trees. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that no community view sheds are in the vicinity of the project. d. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the proposed second story addition complies with the maximum height limitation of 26 feet allowable for residential structures; the building has varying architectural forms and exterior materials to break up the appearance of mass, the building setbacks comply with those required for the R-1-20,000 zoning district. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood and streetscape. This finding may be made in the affirmative in that the project includes a condition of approval that front yard landscaping is to be installed prior to building department final 120 14780 Montalvo Road Application # PDR21-0018/ARB21-0067 February 9, 2022 Resolution #22-004 Page | 9 inspection. Staff will ensure that this landscaping is complimentary to the neighborhood and streetscape. The City Code requires that at least 50% of the front setback area be landscaped. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding may be made in the affirmative in that the home is similar in mass and height with the homes in the neighborhood and will not cast shadows on the adjacent properties which could impair the adjacent property owner’s opportunity to utilize solar energy. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk and avoiding unreasonable interference with privacy and views as detailed in the findings above. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. 121 Community Development Department 13777 Fruitvale Avenue Saratoga, CA 95070 www.saratoga.ca.us/171/trees 831.291.1344 CITY OF SARATOGA ARBORIST APPROVAL Conditions of Approval and Tree Protection Plan Prepared by Katelyn Obana, Contract Arborist Application No.ADR21-0023/ARB21-0067 Phone: (831) 291-1344 Address:14780 Montalvo Rd. Email: Katelyn.Obana@Davey.com Owner:Fan Yang APN:517-20-033 Date:September 2, 2021 PROJECT SCOPE: The applicant has submitted plans to expand the 1st and 2nd floor, and revamp the porch and foyer leading to the 2nd floor ADU. Two (2) trees that are protected by City Code are requested for removal to construct the project. PROJECT DATA IN BRIEF: Tree security deposit –Required - $22,350 Tree protection –Required – See Conditions of Approval and attached map. Tree removals –Two trees (Tree #1 & #3) are approved for removal once building permits have been issued. Replacement trees –$8,740 ATTACHMENTS: 1 – Findings and Tree Information 2 – Tree Removal Criteria 3 – Conditions of Approval 4 – Map Showing Tree Protection 1 122 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 Attachment 1: FINDINGS Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. One persimmon (tree #1) and one Saratoga sweet bay (tree #3) have been deemed necessary for removal by the project arborist in order to construct this project. These trees meet the City ’s criteria allowing them to be removed and replaced as part of the project, once building division permits have been obtained. The table below contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No.Species Criteria met Comments T1 Persimmon 6,9 In conflict with design. T3 Saratoga sweet bay 6,9 In conflict with design. New Construction Based on the information provided, and as conditioned,this project complies with the requirements for the setback of new construction from existing trees under Section 15-50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1.Shall include the sections Impacts on Protected Trees and Tree Protection Recommendations from the arborist report by Bo Firestone dated June 25,2021; 2.Shall include the Project Data in Brief, the Conditions of Approval, and the Map Showing Tree Protection sections of the Contract City Arborist report dated September 2, 2021. 2 123 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 Attachment 1: TREE INFORMATION Project Arborist:Bo Firestone Date of Amended Report:June 25, 2021 Number of protected trees inventoried:6 Number of protected trees requested for removal:2 A table summarizing information about each tree is below. Table 1: Tree information & appraisal values from submitted arborist report dated 6/25/2021. Total Value of Appraised Trees to Remain:$44,700 Appraised Value of Removals:$8,740 Required Security Deposit (50%):$22,350 3 124 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 Attachment 2: TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below,the tree(s) may be approved for removal and replacement during construction. (1)The condition of the tree with respect to disease,imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2)The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. (3)The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. (4)The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. (5)The age and number of healthy trees the property is able to support according to good forestry practices. (6)Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7)Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8)Any other information relevant to the public health,safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9)The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. (10)The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. 4 125 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 Attachment 3: CONDITIONS OF APPROVAL 1.Owner, Architect, Contractor:It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2.Permit: a.Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. b.No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 3.Final Plan Sets: a.Shall include the Impacts on Protected Trees and Tree Protection Recommendations from the arborist report by Bo Firestone dated June 25, 2021 copied onto a plan sheet. b.Shall include the Project Data in Brief, the Conditions of Approval, and the Tree Protection Map showing tree protection sections of the City Arborist report dated September 2, 2021. 4.Tree Protection Security Deposit: a.Is required per City Ordinance 15-50.080. b.Shall be $22,350 for tree(s)#2, #4-6. c.Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d.May be in the form of cash, check, or a bond. e.Shall remain in place for the duration of construction of the project. f.May be released once the project has been completed,inspected and approved by the City Arborist. 5.Tree Protection Fencing: a.Shall be installed as shown on the attached map. b.Shall be shown on the Site Plan. c.Shall be established prior to the arrival of construction equipment or materials on site. d.Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. e.Shall be posted with signs saying, “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CONTRACT CITY ARBORIST, KATELYN OBANA (831) 291-1344”. f.Wherever protection is needed outside of fences, unprocessed wood chips, or approved equivalent, shall be placed to the edge of the tree’s canopy and to a depth of 6 inches. g.Call Contract City Arborist, Katelyn Obana at (831)291-1344 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. h.Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 6.Construction:All construction activities shall be conducted outside tree protection fencing unless permitted as conditioned below. These activities include, but are not necessarily limited to, the 5 126 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 following: demolition, grading, trenching for utility installation, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 7.Work inside fenced areas: a.Requires a field meeting and approval from City Arborist before performing work. b.Requires Project Arborist on site to monitor work. 8.Project Arborist: a.Shall be Bo Firestone unless otherwise approved by the City Arborist. b.Shall visit the site every two weeks during grading,trenching or digging activities and every six weeks thereafter. A letter/email shall be provided to the City after each inspection which documents the work performed around trees, includes photos of the work in progress, and provides information on tree condition during construction. c.Shall supervise any permitted pruning or root pruning of trees on site. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. 9.Tree removal: Trees #1 & #3 meet the criteria for removal and may be removed once building division permits have been obtained. 10.New trees: a.New trees equal to $8,740 shall be planted as part of the project before final inspection and occupancy of the new home. New trees may be of any species and planted anywhere on the property as long as they do not encroach on retained trees. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b.Trees shall be replaced on or off site according to good forestry practices, and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. 11.Damage to protected trees that will be retained: a.Should any protected tree be damaged beyond repair,new trees shall be required to replace the tree. If there is insufficient room to plant the necessary number of new trees, some of the value for trees may be paid into the City ’s Tree Fund.Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 Water loving plants and lawns are not permitted under oak tree canopies. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 6 127 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 12.Final inspection: At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call City Arborist for a final inspection. Before scheduling a final inspection from the City Arborist, have the project arborist do an inspection, prepare a letter with their findings and provide that letter to the City for the project file. 7 128 14780 Montalvo Rd.City of Saratoga Arborist Review September 2, 2021 Attachment 4:Map Showing Tree Protection: From submitted arborist report dated 6/25/2021 8 129 130 131 132 133 134 135 136 CHRISTENSEN & PLOUFF LAND SURVEYING 101 Church Street, Suite 29, Los Gatos. Ca 95030 TEL # (408) 755-9784 info@cplandsurveying.com www.cplandsurveying.com December 12, 2021 To: City of Saratoga Re: 14780 Montalvo Rd, Saratoga I, Kacie A. Plouff, hereby certify that I am a Professional Surveyor in the State of California holding license no. 9013. I further certify that a survey was performed on the subject property to measure the existing grades and the location and height of the story poles placed on the property to represent the proposed roof line. We certify that the location and height of the story poles matched the data as shown on the approved plans. _________________________________________ Kacie A. Plouff PLS#9013 137 1 | Page Story poles shall be constructed of wood or metal which delineate the height, area, and approximate shape and massing of a proposed structure. Story poles must be installed in the manner set forth below: 1) On each building elevation of the proposed structure at least one story pole shall show graduated five-foot interval height measurement markings in either paint or tape. 2) At least one building elevation of the proposed structure must show the proposed finished grade and finished floor elevation markings in either paint or tape. 3) The story poles shall be erected so that orange netting (or other materials approved by the Community Development Director) will be used to approximate the mass, shape and roofline (e.g., roof pitch/slope, ridge, and volume, including covered porches) of the proposed structure as shown below. For complex roof forms, the Community Development Director may also require that ridge flags be installed to delineate a main roof ridge or high point. Community Development Department City of Saratoga 13777 Fruitvale Avenue Saratoga, California 95070 Story Pole Requirements 138 139 140 N.T.S.PROJECT DIRECTORYOwner : Fan YangAdress; 14780 Montalvo Rd..Saratoga, CA 95070Email: fan8ge@gmail.comPhone #: 408 666 3436Architect: LNX Architecture inc.Address: 6710 Corte Snata Maria,Pleasanton, CA 94566Responsible Person: Yuan Lin, ArchitectPhone#: 925 357 5801Email: yuanlinco@163.comStructural Engineer:AQX Engineering Inc.6525 Crown Blvd. #41068San Jose, ca 95168Responsible Person: Joe Chyou,Email: chyou88@gmail.comDRAWING DIRECTORY& SITE PLANPROJECT INFO.LOCATION: 14780 MONTALVO RD. SARATOGA, CA 95070 CODE COMPLIANCE:2019 CBC,CMC,CPC,CEC, CRC2019 CAL GREEN STANDARDS2019 CALIFORNIA ENERGY CODELOCAL CITY CODES AND ORDINANCESSCOPE OF WORK:1.Add 428sf to the main house--223sf on 1st floor+ 205sf loft on 2nd floor;2.Modify foyer area , add stairs, lower floor level for easyaccess to the existing living room3.Remodel and re-arrange kitchen, add sliding doors to thebackyard4.Remodel and partially re-arrange Master Bath5.0RGLI\JDUDJHWRDOORZIRUWZR¶[¶GRRUV6. Add a 2B2B ADU on the 2nd floor with stairs to theexterior7. Add 100 amp new panel and new furnace for ADU.8. Extend and reroute ducts to serve new additionand modified space.9. All existing utility lines and water heater shall remain in use for the main house.VICINITY MAP NSCALE: 1"=10'-0"14780 MONTALVO RD. SARATOGA, CA 95070PLAN NORTHTOTAL CONDITIONED BUILDING AREA: LOT SIZE:20,172 SFCONSTRUCTION TYPE: TYPE V,BCOVER SHEETSITE PLANFRONT ELEVATIONSITE PLAN NOTES1. SEE GENERAL NOTES ON A2.1 FOR ADDITIONAL INFORMATION2. THE SITE PLAN IS NOT A SURVEY. IT IS PROVIDED FOR BUILDING AND LIMITED SITE PLANLAYOUT ONLY. THE CONTRACTOR SHALL VERIFY IN FIELD ALL GRADES, EXISTINGIMPROVEMENTS, PROPERTY LINES AND SETBACKS, EASEMENTS, UTILITIES ANDSUBSTRUCTURES. SITE SPECIFIC SOILS REPORTS AND CIVIL DRAWINGS SHALL TAKEPRECEDENCE OVER NOTES AND DETAILS ON THIS SET OF DOCUMENTS.3.THIS PLAN IS NOT A GRADING AND DRAINAGE OR EROSION CONTROL PLAN. CONSULT A CIVILENGINEER FOR SUCH INFORMATION.4. VEGETATION CLEARANCE SHALL COMPLY WITH CBC 701A.3.2.45. ALL GRADING, SITE PREPARATION, PLACEMENT AND COMPACTION OF FILL IS TO BE DONE INACCORDANCE WITH THE CITY OF SARATOGA GRADING ORDINANCE6. AT A MINIMUM, THE PAD GRADE UNDER BUILDING SHALL HAVE POSITIVE SLOPE TO A MINIMUMOF ONE AREA DRAIN WHICH SHALL BE PIPED TO STREET(OR OTHER SUITABLE DISCHARGEPOINT DETERMINED BY THE CIVIL ENGINEER AND/OR LOCAL GOVERNING AUTHORITY ), VIA ANON-CORROSIVE DEVICE.7. ALL FOUNDATION PERIMETER AND ROOF DRAINAGE SHALL BE PIPED TO STREET ORAPPROVED DISCHARGE SYSTEM.8. IRRIGATION SYSTEM SHALL BE DESIGNED TO PREVENT SATURATION OF SOIL ADJACENT TOTHE BUILDING, STRUCTURES, OR UTILITY BOXES.9.NOT USED10. WATER SHOULD BE PREVENTED FROM PONDING ANYWHERE ON THE LOT PARTICULARLYNEAR THE HOUSE. WATER FROM DOWN SPOUTS AND YARD DRAINS SHOULD BE DIRECTEDTOWARD FRONT, BACK AND SIDE LANDSCAPED AREA.11.CRAWL SPACES SHOULD BE GRADED IN SUCH A WAY THAT WATER WHICH MAY STILL ENTERTHE CRAWL SPACE FLOWS TO A LOW POINT WHERE IT CAN BE PIPED BENEATH THE PERIMETERFOUNDATION (GRADE BEAM OR "T" FOOTING ) AND DISCHARGED.12.AT ALL RETAINING WALLS, LANDSCAPE WALLS OR CLOSE PROXIMITY TO STRUCTURES,PROTECTIVE SUB DRAINAGE SHALL BE INSTALLED BENEATH THE FILLS IN THE SWALE AREAS.THE SUB DRAINS SHOULD CONSIST OF A BLANKET OR TRENCH FILLED WITH CLASS TWOPERMEABLE MATERIAL AND HAVING A WIDTH OF AT LEAST 18 INCHES. THE SUB DRAINS SHOULDHAVE A VERTICAL HEIGHT OF 4 FEET AND SHOULD BE INSTALED AT THE BACK OF THE LOWESTELEVATION POSSIBLE TO PERMIT DAYLIGHT DRAINAGE ON THE PROPERTY(OR TO ANAPPROVED DISCHARGE SYSTEM). ENDS OF PIPES SHALL BE RIP RAPPED SO THEY WILL NOTBECOME BLOCKED IN THE FUTURE. SLD. AND SEE CIVIL AND LANDSCAPE PLUS SEE DETAILSFOR ANY REQUIRED WATERPROOFING ALONG THE VERTICAL FACE OF ANY BURIED WALLS.(N) ADDITIONSHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADU -- A REMODEL/ADDITION & ADU PROJECTEXISTING WALL TO REMAINNEW WALLEXISTING TO BE REMOVEDFLOOR PLAN LEGENDNEW CONSTRUCTION AREALOWEST PT.FROM NATURAL GRADEHEIGHT TABLEFRONTSETBACK TABLELEFTRIGHTREARREQ'DACTUAL HIGHEST PT.FROM NATURAL GRADEAVE. ELEV. PT.FROM NATURAL GRADETOP MOST ELEV. POINT --MEASUREDFROM AVE. ELEV.PT.TO TOP OF ROOFHOUSE FOOTPRINT +PORCHSITE COVERAGEDRIVEWAY(PERMEABLE)WALKWAYS+ PATIOACCESSORY STRUCT.(GAZEBO)% OF LOTSITE COVERAGE TOTAL 30'15'15'35'39'-9"(N)61'-1"(N)21'-10"(N)46'-10"(N)A-1.1FLOOR AREAFLOOR AREA TABLE1ST FLOOREXISTING PROPOSED TOTALPORCH3587 SF 223 SF 3810 SF31TOTAL DESIGNED4511 SF<4518 SF4052 SF 459 SF24.5%2.54%12.18%0.62%529.16526.60527.88HEIGHT ELEVATIONOCCUPANCY TYPE: R-3BUILDING STORIES:2 STORYIT IS IN THE WILDLAND-URBAN INTERFACE FIRE AREA BUTNOT IN THE FLOOD ZONE.NOTE:1. PRIOR TO ANY GRADING, SCRAPING, OR TRENCHINGWITHIN/UNDER THE CANOPY OF A PROTECTED TREE, A CERTIFIEDARBORIST SHALL BE RETAINED TO PROVIDE SUPERVISION ANDRECOMMENDATIONS TO MINIMIZE POSSIBLE DAMAGE TO THE TREE.PROPOSED TRENCHING SHALL BE APPROVED BY THE CITY OFSARATOGA PLANNING DEPT. PRIOR TO ANY DIGGING. THE CITY OFSARATOGA ARBORIST IS: KATE BEAR 408 868 127641%<55%+GARAGE+EAVE OVERHANGSQ. FT.1025/2=5131258274 TOTAL CONDITIONED AREA3810+205=4015 SFGARAGE 465 SFN/A465 SFPROJECT SITEAPN:517-20-033A-1.1 COVER SHEET AND SITE PLANA-1.2 DEMOLITION FLOOR PLAN/(E) ELEVATIONSA-1.3 NEIGHBORHOOD IMAGESA-2.1a PROPOSED 1F FLOOR PLAN & GENERAL NOTESA-2.1b PROPOSED 2F FLOOR PLANA-2.2 PROPOSED ROOF PLANA-3.1 BUILDING ELEVATIONSA-3.2 BUILDING ELEVATIONSA-3.3 BUILDING SECTIONSA-4 DETAILSA-5.1 CAL GREEN CHECKLISTA-5.2 CAL GREEN CHECKLISTA-6 BEST MANAGEMENT PRACTICE (BMP)T-24.1 T24 REPORTT-24.2 T24 REPORTT-24.3 T24 REPORTSTRUCTURAL:S1 STRUCTURAL NOTESS2 STRUCTURAL DETAILSS3 FOUNDATION PLANS4 ROOF FRAMING PLANGAS METERWATER METERCOMM.UTILITYMAILBOXREMOVE(E) 12" TREEREMOVE(E) 6" TREE1ST FLOOR ADDITION2ND FLOOR ADDITION2ND FLOOR ADU1199 SFADU1F SETBACK LINEPROPERTY LINEREMOVE(E) 12" TREESPRINKLER SYSTEM:YES2ND FLOOR N/A205 SF 205 SFALL (E) BACKYARDLANDSCAPING TO REMAIN, U.N.O.ALL (E) SIDEYARDLANDSCAPING TO REMAIN, TYP.ALL (E) SIDEYARDLANDSCAPING TO REMAIN, TYP.(E) HOUSE1F ROOF(E) HOUSE1F ROOF(E) HOUSE1F ROOF(E)PERMEABLEPAVING(E) PERMEABLE PAVING(E) WALKWAY TO REMAIN1F SETBACK LINE2F SETBACK LINE1F SETBACK LINE2F SETBACK LINE1FACTUAL 30'(E)16'-10"(N)14'-3"(E)36'-9"(E)1FREQ'D35'20'20'45'2FMAIN HOUSE: 4015 SFADU:1199 SFFRONT PATIOREMOVE PAVING2284(e)+172(n)NEW CONSTRUCTION AREA(E) CONC.PAVINGPERGOLA(E)FISH POND 1.2%240N/A31ZONING:R-1 20000AVE. SITE SLOPE:7.5%(E)PONDGAS MTR.ACACALLOWABLE FLOOR AREA4050+6x78=4518 SFNOTE:1). THE SITE IS GREATER THAN 10,000SF. THE ADU IS DEED RESTRICTED. DECK12354635PROTECTED TREE TO REMOVEPROTECTED TREE TO REMAINTREE PROTECTION LEGENDTREE PROTECTION FENCINGNOTE: SEE ARBORIST REPORT FOR MORETREE PROTECTION FENCING TREE PROTECTION FENCING (E) DRIVEWAYTO REMAIN2. ALL UTILITY LINES AND CONNECTION POINTS WILL REMAIN ASEXISTING AND WILL NOT BE CAPPED OR REPLACED.3. ALL WALKWAYS TO BE OF PERMEABLE PAVING(SEE ARBORIST REPORT FOR MORE DETAILS)(SEE ARBORIST REPORT FOR MORE DETAILS)OF PERMEABLE PAVINGNEW WALKWAY TO BETHE ADU IS DEED RESTRICTED . THERE IS A 10% SITE COVERAGE INCREASE APPLY (E) FIRE DEPT.KEY BOX553.77 (25.89')FIRE HYDRANT LOCATION MAP N.T.S.DETAILSA FIRE HYDRANT IS WITHIN 400 FT OF THE PROJECT SITE TO REMAINADU FLOOR AREA PERMITTED ADU TO USE THE 10% AREA BONUS399 SF <452 SFADU 2). FRONT PORCH IS OPEN ON 2 SIDES AND IS NOT CALCULATED INTO TOTAL FLOOR AREA. A 10% FLOOR AREA AND SITE COVERAGE INCREASE APPLY.800 SF2MAIN HOUSE REMOVE(E) 8" TREEADU DESIGNED AREA:800+ 399=1199 SF10% FLOOR AREA INCREASE10%X4518=452 SF1TREEDEAD4052(e)+339(n) =4940=245638.5%7,214(e)141 DEMOLITIONEXISTING WALL TO REMAINEXISTING WALL/WINDOW TO BE REMOVEDFLOOR PLAN LEGENDFLOOR PLAN/EXISTING RIGHT SIDE ELEVATION (EAST)SCALE: 1/8"=1'-0"4EXISTING LEFT SIDE ELEVATION (WEST)SCALE: 1/8"=1'-0"5EXISTING FRONT ELEVATION (SOUTHEAST)SCALE: 1/8"=1'-0"6SHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADU(E) ELECATIONS/DEMOLITION FLOOR PLANSCALE: 3/16"=1'-0"2EXISTING DOOR TO BE REMOVEDPLAN NORTHA-1.2EXISTING ROOF EAVE TO BE REMOVEDEXISTING REAR ELEVATION (NORTH)SCALE: 1/8"=1'-0"3(E) SLATE ROOF, TYP.(E) STICCO WALL, TYP.(E) CHIMNEYFLOOR AREA CALCULATIONSCALE: 1/16"=1'-0"1A(E) SLATE ROOF, TYP.(E) STICCO WALL, TYP.(E) CHIMNEY(E) DUAL PANE WINDOWROOF AREA CALCULATIONSCALE: 1/16"=1'-0"1BEXISTING EXT. WALL TO REMAIN20EXISTING EXT. WALL TO BE REMOVED(20)OR COVERED(EXT. WALL DEMO. CALCULATION)142 A-2.1a1ST FLOOR PLAN PROPOSED 1ST FLOOR PLANSCALE: 1/4"=1'-0"EXISTING WALL TO REMAINNEW WALLCEILING HEIGHT CHANGE LINENEW LIVING SPACE1SHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADUPLAN NORTHLEGENDTTEMPERED GLAZINGOFFICEFOYERDININGKITCHENFAMILYLIVINGLIVINGCL.￿￿BEAMSAVE A SECT.BRSTUDYM. BR.W.I.C.LAUNDRYOF WALLGARAGEPATIOSLIDING DOORM. BATH- 9 SF+ 11 SF+ 224 SF+ 2.5 SF- 6 SFREMODEL KITCHENREMODEL M. BATHADD STAIRNEW FOYERCLOSE OFF(E) ENTRYPORCH(N) ADDITION(NO CHANGE)(NO CHANGE)(NO CHANGE)(NO CHANGE)(NO CHANGE)(NO CHANGE)(NO CHANGE)(NO CHANGE)(NO CHANGE)(N) METAL STAIRTO ADU @ 2FBBAABREAKFAST + 31 SF143 A-2.1b2ND FLOOR PLANPROPOSED 2ND FLOOR PLANSCALE: 1/4"=1'-0"EXISTING WALL TO REMAINNEW WALLCEILING HEIGHT CHANGE LINENEW LIVING SPACE1SHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADULEGENDTTEMPERED GLAZINGDININGLIVINGKITCHENBR1BR2BR2W.I.C.BR1LOFTMAIN HOUSEADUDECKskyltskyltFAUROOF BELOWROOF BELOWPORCHPLAN NORTH144 A-2.2SCALE: 1/4"=1'-0"ROOF PLAN1PROPOSED ROOF PLAN1. ROOF PLATE HEIGHTS ARE REFERENCED FROM TOP OF SUB FLOORAT ENTRY, U.N.O.2. CLASS A ROOF COVERING IS REQUIRED BY CITY OF SARATOGA. ROOF COVERING SHALL BE : SLATE ROOFINGMANUFACTURER: EAGLE ROOFING OR EQUALTYPE: SLATE TO MATCH (E)COLOR: MATCH (E)3. GUTTERS ON ALL ELEVATIONS SHALL BE PROFILED ALUMINUMGUTTERS BY AMERIMAX OR EQUAL4. ROOF PITCH SHALL BE AS NOTED ON ROOF PLAN5. OVERHANG DIMENSIONS ARE AS NOTED ON PLAN6. DASHED LINES INDICATE WALL(STRUCTURE) BELOW.7. LOCATE GUTTERS AND DOWNSPOUTS AS SHOWN. NOTE: LOCATEDOWNSPOUTS MIN. 8" OFF CORNER WHERE POSSIBLE (U.O.N.)8. ALL ROOF DRAINAGE SHALL BE PIPED TO STREET OR APPROVEDDRAINAGE FACILITY.9. ALL PLUMBING VENTS SHALL BE COMBINED INTO A MINIMUMAMOUNT OF ROOF PENETRATIONS. ALL ROOF PENETRATIONS SHALLOCCUR TO THE REAR OF THE MAIN RIDGE (WHERE POSSIBLE) SEEDETAIL 7/A-410. ATTIC VENTILATION SHALL BE PROVIDED PER SECTION 1505.3 OFTHE UBC. (SEE CALCULATIONS, THIS SHEET)11. LOCATE ROOF VENTS AS SHOWN.12. FLASH ALL ROOF VALLEYS (INSTALL FLASHING OVER 30# FELT)13. ALL FLASHING SHALL BE 26 GAUGE G.S.M.ROOF PLAN NOTESSHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADUPLAN NORTH(N) 2F ROOF(E)1F ROOF(E)1F ROOF(N) 1F ROOFFLAT ROOF AREA(E)1F ROOFDECK(E)1F ROOF(N) ROOF LINE(E) ROOF LINEEXT. WALL LINE BELOWROOF PLAN LEGEND(N) 2F ROOFACFIREPLACE VENT(E) CHIMNEYSKYLIGHTSKYLIGHT145 SHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADU ELECATIONSA-3.1PROPOSED LEFT SIDE ELEVATION (SOUTHWEST)SCALE: 1/4"=1'-0"1(N) SLATE ROOF TO MATCH (E)PROPOSED FRONT ELEVATION (SOUTHEAST) SCALE: 1/4"=1'-0"2(N) 3-COAT STUCCO WALL, TYP.(N) DUAL PANE WINDOWS(N) METAL GUTTER(E) SLATE ROOF TO REMAIN(N) 8'X8' INSULATED GARAGE DOORREMOVE (E) STONE, APPLY 3-COAT STUCCOREMOVE (E) STONE, APPLY 3-COAT STUCCOREPLACE (E) WINDOW W/(N) DUAL PANE WINDOW(N) METAL FRONT DOORS(N) 3-COAT STUCCO WALL, TYP.(E) WINDOW TO REMAIN(E) STUCCO FINISH, REPAINT TO MATCH (N)(N) 3-COAT STUCCO WALL, TYP.PAINT TO MATCH (N)PAINT TO MATCH (N)SHEET NOTES1. EXTERIOR STUCCO SHALL BE: (1) 3-COAT, 7/8 INCH MINIMUM THICK; (2) HAS TWO LAYERS OFGRADE D BUILDING PAPER UNDER STUCCO WHERE OCCURS OVER PLYWOOD SHEATHING; AND (3)HAS 26 GAGE GALVANIZED WEEP SCREED AT FOUNDATION PLATE LINE AT LEAST 4 INCHES ABOVEGRADE (OR 2 INCHES ABOVE CONCRETE OR PAVING). CRC R703.6.2 AND R703.6.3WINDOW LEGEND:(E) WINDOW(N) WINDOW146 SHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADU ELECATIONSA-3.2PROPOSED REAR ELEVATION (NORTHWEST)SCALE: 1/4"=1'-0"1(N) STAIRCASE LEADING PROPOSED RIGHT SIDE ELEVATION (NORTHEAST)SCALE: 1/4"=1'-0"2TO ADU @ 2FFILL IN EXT. WALL CLOSE OFF (E) WINDOWSW/3-COAT STUCCO FINISHINGSHEET NOTES1. EXTERIOR STUCCO SHALL BE: (1) 3-COAT, 7/8 INCH MINIMUM THICK; (2) HAS TWO LAYERS OFGRADE D BUILDING PAPER UNDER STUCCO WHERE OCCURS OVER PLYWOOD SHEATHING; AND (3)HAS 26 GAGE GALVANIZED WEEP SCREED AT FOUNDATION PLATE LINE AT LEAST 4 INCHES ABOVEGRADE (OR 2 INCHES ABOVE CONCRETE OR PAVING). CRC R703.6.2 AND R703.6.3WINDOW LEGEND:(E) WINDOW(N) WINDOW147 SHEET NO.SARATOGA, CA 95070 TEL:925 357 5801 PLEASANTON, CA 94566 6710 CORTE SANTA MARIAREVISIONSPROJECT NAMEDATE: 05/21/2021SCALE: AS SHOWNYUAN LINRENEWALDATEC-2799912/31/2021OWNER: Mr. Yang, Fan, TEL: 408 666 3436SHEET NAME14780 MONTALVO ROAD REMODEL, ADDITION & ADUSECTIONSA-3.3BUILDING SECTION A-ASCALE: 1/4"=1'-0"1BUILDING SECTION B-BSCALE: 1/4"=1'-0"2148 REPORT TO THE PLANNING COMMISSION 13251 Quito Road Meeting Date: February 9, 2022 Application: PDR21-0020 Address/APN: 13251 Quito Road / 389-18-049 Applicant / Property Owner: Jawwad Sultan Khan From: Debbie Pedro, Community Development Director Report Prepared By: Christopher Riordan, Senior Planner 149 Report to the Planning Commission 13251 Quito Road– Application #s PDR21-0020 February 9, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a project which includes removal of an existing 1,578 square foot one story single-family residence and the construction of a new 3,879 square foot one story single-family residence with an attached 530 square foot accessory dwelling unit. The height of the project will not exceed 22’-3”. No protected trees are proposed for removal. STAFF RECOMMENDATION Adopt Resolution No. 22-006 approving the project subject to conditions of approval included in Attachment 1. Pursuant to City Code Section 15-45.060(a)(3), Design Review Approval by the Planning Commission is required as the project includes a new structure over eighteen feet in height. PROJECT DATA Gross/Net Site Area: 10,001 sq. ft. gross/net (.230 acres) Average Site Slope: Level Site General Plan Designation: M-10 (Medium Density Residential) Zoning: R-1-10,000 Proposed Allowed/Required Site Coverage Residence/Garage Driveway Walkways/Patios/Decks Total Proposed (structures) 3,922 sq. ft. 661 sq. ft. 1,179 sq. ft. 5,762 sq. ft. (58%) 6,000 sq. ft. (60%) Floor Area Main Residence Living Area Attached Garage Total Floor Area 2,853 sq. ft. 496 sq. ft. 530 sq. ft. 3,879 sq. ft. 4,170 sq. ft.* Height 22’-3” 26’ Setbacks Front: Left Side: Right Side: Rear: 25’-3” 8’-0” 8’-0” 25’-0” 25’ 8’ 8’ 25’ Grading Cut 346 CY Fill 8 CY Export 338 CY No grading limit in the R-1-10,000 zoning district. * Includes allowance for an accessory dwelling unit of at least 800 square feet. 150 Report to the Planning Commission 13251 Quito Road– Application #s PDR21-0020 February 9, 2022 Page | 3 SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The project site is located at 13251 Quito Road in the R-1-10,000 zoning district near the intersection of McCoy Avenue and Quito Road. The site contains an existing 1,578 square feet one-story single-family residence. One redwood tree is located in the rear yard. The site is not located in a geologic unstable area. Surrounding uses in the immediate vicinity include predominantly one-story single-family residences. Project Description The architectural style of the proposed residence can best be described as “Contemporary”. Architectural features will include a taller building form in the center of the building footprint with shorter architectural elements on both sides. Exterior windows will be both square and rectangular in shape. Exterior materials include off- white colored stucco and trim with the exception of the center portion of the front elevation which will be covered with natural colored El Dorado stone. Windows will be black colored fiberglass. The roof will be a Tesla solar roof. A colors and materials board prepared by the applicant is included as Attachment 4. Below is a list of the proposed exterior materials. Detail Colors and Materials Exterior Off-White Colored Stucco and El Dorado Stone Windows / Trim Black Colored Fiberglass Windows and Off-White Colored Trim Garage Door Wood with Horizontal Glass Window Roofing Tesla Solar Roof Trees A 33-inch redwood tree is located in the rear yard. The project will be located more than five feet away from the dripline of the tree therefore City Arborist review was not required. A condition of approval has been added that tree protection fencing be installed around the dripline of the tree prior to building permit issuance. Landscaping Proposed front yard landscaping would include decorative boulders, drought tolerant shrubs, and bark. Solid surfaces would include a new concrete driveway and poured in place concrete steps leading from the sidewalk to the front entrance. FINDINGS The findings required for issuance of a Design Review Approval pursuant to City Code Section Article 15-45.080 are set forth below and the Applicant has met the burden of proof to support making all of those required findings: a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the 151 Report to the Planning Commission 13251 Quito Road– Application #s PDR21-0020 February 9, 2022 Page | 4 affirmative in that the project minimizes changes to the contours of the site. Grading will be limited to leveling the site to create a flat building pad and contouring the site to direct stormwater to landscaping and retention areas. Grading is minimized as the site is relatively level and the new structure will be located in approximately the same location as the existing structure to be removed. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that no protected trees are proposed for removal. Tree protection fencing is required to be installed to protect the redwood tree located in the rear yard prior to the issuance of building permits and will remain in place for project duration. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the project is a single-story structure with a maximum height of 22’-3” with no second story windows or elevated decks or balconies to impact the privacy of adjoining properties. No community view sheds are in the vicinity of the project. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that even though the project will be a single-story structure, the proposed roof height of 22’-3” is taller than the existing homes on either side. The difference in building height and the perception of mass and height of the structure is reduced by locating the taller portion of the project at the center of the building footprint and in the center of the site. To transition the building height to the shorter homes on either side with lower roof and plate heights, both side architectural building forms of the proposed structure are lower in height then the adjacent homes e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the landscape design minimizes the percentage of hardscape in the front and exterior side setback areas. Proposed front yard landscaping would include decorative boulders, drought tolerant shrubs, and bark. Solid surfaces would include a new concrete driveway and poured in place concrete steps leading from the sidewalk to the front entrance. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing and the project meets or exceeds required setbacks. 152 Report to the Planning Commission 13251 Quito Road– Application #s PDR21-0020 February 9, 2022 Page | 5 g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative in that the proposed project incorporates applicable design policies and techniques from the Residential Design Handbook. The overall mass and height of the structure are mitigated by the design and its architectural elements; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. Neighbor Notification The applicant provided two neighbor notification forms (Attachment 2) neither of which included project related comments. The public hearing notice and description of the project was published in the Saratoga News and notices were mailed to all property owners within 500 feet of the project site. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of three single-family residences in a residential area. The project, as proposed, is for the construction of a new residence in a suburban, residential area. ATTACHMENTS 1. Resolution No. 22-006 2. Neighbor Notification Forms 3. Story Pole Certification 4. Materials Board 5. Project Plans 153 RESOLUTION NO: 22-006 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0020 13251 QUITO ROAD (APN 389-18-049) WHEREAS, on July 25, 2021 an application was submitted by Jawwad Sultan Khan (Applicant) requesting Design Review approval to construct a new 3,879 square foot one-story single-family residence with an attached 530 square foot accessory unit. No protected trees are proposed for removal. The site is located within the R-1-10,000 zoning district. WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA) and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on February 9, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints; the porch and entry are in scale with other structures in the neighborhood. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. 154 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 2 Section 5: The City of Saratoga Planning Commission hereby approves PDR21-0020, 13251 Quito Road (APN 389-18-049), subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 9h day of February 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Anjali Kausar Chair, Planning Commission 155 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0020 13251 QUITO ROAD (APN 389-18-049) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify, and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. 156 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 4 In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. COMMUNITY DEVELOPMENT DEPARTMENT 5. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 6. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Plans dated January 12, 2022. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 7. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 8. To comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 9. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 157 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 5 10. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 11. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency, and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall consider potential damage to roots of protected trees 12. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 13. A locking mailbox approved for use by the U.S. Postal service shall be installed and in compliance with Saratoga Municipal Code section 6-25.030. The mailbox shall be installed prior to final inspection. 14. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 15. Tree protection fencing shall be installed around the dripline of the redwood tree located in the rear yard prior to building permit issuance. This fencing shall comprise of six-foot high chain link fencing mounted on two-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. This fencing shall remain undisturbed throughout the construction until final inspection. 16. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. Contact West Valley Collection & Recycling (408-283-9250 or customerservice@westvalleyrecycles.com) to schedule delivery of a debris box. 158 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 6 FIRE DEPARTMENT 17. The owner/applicant shall comply with all Fire Department requirements. ENGINEERING 18. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 19. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 20. Applicant / Owner shall make the following improvements in the City right-of-way: a. Remove existing driveway approach and replace with new driveway approach per City Standard Detail 206. See City of Saratoga Standard Details for removal and new installation. New flow line shall conform to existing flow lines and grade. 21. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 22. All new/upgraded utilities shall be installed underground. 23. Applicant / Owner shall maintain the streets, sidewalks, and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 24. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g., landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay- Friendly Landscaping). 25. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing storm water pollution: • Owner shall implement construction site inspection and control to prevent construction site discharges of pollutants into the storm drains per approved Erosion Control Plan. 159 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 7 • The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non- storm water management through all phases of construction (including, but not limited to, site grading, building, and finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. • City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 26. Prior to the commencement of any earthwork/grading activities, the permittee shall arrange a pre-construction meeting. The meeting shall include the City of Saratoga Grading Inspector (408-868-1201), the grading contractor, and the project Soils Engineer. The permittee or representative shall arrange the pre-construction meeting at least 48 hours prior to the start of any earthwork activities. 27. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. 28. Prior to the Building final, all Public Works conditions shall be completed per approved plans. 29. Upon the completion of this project the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the City's building inspector to be properly elevated. Such certification and verification shall be provided to the City’s Floodplain Administrator. BUILDING DEPARTMENT SUBMITTAL 30. Complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. 160 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 8 DESIGN REVIEW FINDINGS PDR21-0020 13251 QUITO ROAD (APN 389-18-049) The findings required for issuance of a Design Review Approval pursuant to City Code Section Article 15-45.080 are set forth below: a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be limited to leveling the site to create a flat building pad and contouring the site to direct stormwater to landscaping and retention areas. Grading is minimized as the site is relatively level and the new structure will be located in approximately the same location as the existing structure to be removed. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that no protected trees are proposed for removal. Tree protection fencing is required to be installed to protect the redwood tree located in the rear yard prior to the issuance of building permits and will remain in place for project duration. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the project is a single-story structure with a maximum height of 22’-3” with no second story windows or elevated decks or balconies to impact the privacy of adjoining properties. No community view sheds are in the vicinity of the project. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that even though the project will be a single-story structure, the proposed roof height of 22’-3” is taller than the existing homes on either side. The difference in building height and the perception of mass and height of the structure is reduced by locating the taller portion of the project at the center of the building footprint and in the center of the site. To transition the building height to the shorter homes on either side with lower roof and plate heights, both side architectural building forms of the proposed structure are lower in height then the adjacent homes e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the landscape design minimizes the percentage of hardscape in the front and exterior side setback areas. Proposed front yard landscaping would include 161 13251 Quito Road– Application # PDR21-0020 February 9, 2022 Page | 9 decorative boulders, drought tolerant shrubs, and bark. Solid surfaces would include a new concrete driveway and poured in place concrete steps leading from the sidewalk to the front entrance. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing and the project meets or exceeds required setbacks. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative in that the proposed project incorporates applicable design policies and techniques from the Residential Design Handbook. The overall mass and height of the structure are mitigated by the design and its architectural elements; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. 162 163 164 165 T.P (1) 111' -0" Ground 98' -0" E-1st F.F. 100' -0"16' - 6"11' - 0"4' - 3"2' - 6"1' - 4"12' - 3"R.R. 121' -2"2' - 0"4' - 10"5' - 5"23' - 2"Scale Project number Date Drawn by Checked by Designer :Adolfo M Martinez Address : 24301Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com 3/16" = 1'-0"11/09/2021 4:15:01 PMRDG-1 MATERIAL BOARD 022-2020 JAWWAD SULTAN KHAN KHAN FAMILY RESIDENCE Issue Date Author Checker TESLA Solar Roof Stucco finish with White Dove by B. Moore Code #f0efe6 Marvin Essential Fiber Glass windows with exterior foam trim. Emilio with Horizontal Clear glass windows 9 ft. x 8 ft. Energy Specialist Team 877.373.7652 Exterior Lights scale:3/16" = 1'-0"1 MATERIAL BOARD El Dorado "Limestone" Exterior front finish No. Description Date 166 www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 551-580-3814 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 01/31/2022 8:19:09 PMA100PROJECT INFORMATION & DATA022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070LOT MAP PROJECT LOCATION DEFERRED SUBMITTAL FIRE SPRINLER SYSTEM WILL BE PROVIDED WITH SEPARATE SUBMITTAL, PERMIT, PLAN REVIEW, INSPECTIONS AND FEES. ROOF TRUSSES DESIGN AND CALCULATIONS WITH APPROVAL LETTER FROM ENGINEER OF RECORD. FIRE DEPARTMENT NOTES: FIRE SPRINKLER SYSTEM IS REQUIRED TO INCREASE TO 600 FEET FROM HYDRANT ON A FIRE APPARATUS ACCESS ROAD. 1. Site Review: Contractor shall verify all conditions and dimensions at the job site. If any discrepancies are found, Contractor shall notify the Architect /Project Coordinator. 2. Code Compliance: The work shall comply with and conform to all laws, rules, codes, ordinances, etc., of the governing body having Jurisdiction over the work, as well as the rules and regulations of the various utility companies serving the building. Nothing In these drawings shall be construed as directions to perform work contrary to. these requirements. Applicable codes Include, but are not limited to, the following: "California Building Code" 2019 edition, State and local building codes. 3. Job Site Conditions: Contractor by accepting contract and beginning the work shall assume sole and complete responsibility for job site conditions during the course of construction including safety all persons and property. This requirement shall apply continuously and not be limited to normal working hours. Contractor shall defend, indemnify and hold the Architect, Engineer and Owner harmless from any and all liability, real or alleged, In connection With the performance or work on this Project. Contractor shall show proof of Worker's Compensation Insurance, as required prior to issuing a permit. 4. Fire Protection: Additional on Site Fire Protection during construction to be provided as required by Fire Inspector or Department. 5. Stored Materials: All materials stored on the site shall be properly stacked and protected to prevent damage and deterioration until use. Failure to protect materials may be cause for rejection of work. 6. Utilities: Contractor shall be responsible for locating, maintaining, relocating and/or removing existing utilities as required. 7. Changes, Additions and Revisions: Prior to the start of any construction work, the General Contractor shall layout the work In conformity With these drawings. Any changes and/or revisions of the structure due to relocation or addition shall be brought to the attention of the Architect prior to the commencement of said change or revisions on. Structural members or elements that require changing or relocation shall be the responsibility of the trade or trades Involved. The Architect or Owner shall not be liable for cost of the changes or revisions required. 8. Workmanship and Materials: All workmanship materials are subject to the approval of the Architect and the Owner. 9. Accessibility: All portions of the work shall be accessible to persons with disabilities as required by Chapter I I B, of the California Building Code 2019 Edition, and Federal Laws, Rules and Regulations. 10. Details: Where certain construction features are not fully shown, the construction shall repeat Similar conditions shown elsewhere. 11. Coordination: The General Contractor must coordinate all phases of the project, including work done by others, to Insure the smooth progress of the project. The General Contractor is also responsible for the receiving and safekeeping of all Items shipped to the job site for the project for his use or others. 12. Guarantee: All work is to be done In a first class workmanship manner. All work done by the General Contractor or subcontractors must be guaranteed for a minimum of one year and prompt repair or replacement of defective Items must be provided at the notice of the Owner. 13. Safety Measures: At all times, the Contractor shall be solely and completely responsible for conditions of the Job site including the safety of persons and property and for all necessary Independent engineering and/or architectural review of these conditions. The Contractor shall also provide and maintain fire extinguishers and other equipment as required by local codes for proper fire protection during construction. 14. Job Site Maintenance: The General Contractor shall maintain the premises In a clean and orderly fashion during the entire construction period, removing all trash and rubbish from the Job site. Upon completion of all construction, the General Contractor shall perform a general clean-up of the premises In order to facilitate the turnover to the Owner. 15. Mechanical: Any of the work shall be on a DESIGN/ BUILD basis. The contractor shall submit all plans and other necessary Information to the local Building Officials to their satisfactions.All work on the mechanical system shall conform to the requirements of the "California Mechanical Code", 2019 adopted edition, California's Title 24 and state and local codes. 16. Plumbing: Any of the work shall be on a DESIGN/ BUILD basis. The contractor shall submit all plans and other necessary information to the local Building Officials to their satisfactions. All work on the plumbing system shall conform to the requirements of the "California Plumbing Code", 2019 adopted edition, California's Title 24 and state and local codes. 17. Electrical: Any of th.e work shall be on a DESIGN/ BUILD basis. The contractor shall submit all plans and other necessary information to the local Building Officials to their satisfactions. All work on the electrical system shall conform to the requirements of the "California Electrical Code", 2019 adopted edition, California's Title 24 and state and local codes. GENERAL NOTES PROJECT TEAM SCOPE OF WORKAPPLICABLE CODES PROJECT DATA DRAWING INDEX VICINITY MAP REBUILD KHAN RESIDENCE + ADU APN # 389-18-049 OWNER: JAWWAD SULTAN KHAN 13251 QUITO ROAD SARATOGA, CA 95070 551-580-3184 jsk2564@gmail.com Civil Engineer: STERLING CONSULTANTS 46560 FREMONT BOULEVARD UNIT No 205.FREMONT, CA 94538 Ph: 510-344-8955 x100 1sterlingconsultants@gmail.com PROJECT DESCRIPTION: BUILDING OCCUPANCY: USE SFR " R-1-10,000 SINGLE FAMILY RESIDENCE " STORIES : PROPOSED 1 PROPERTY ADDRESS:13251 QUITO ROAD SARATOGA, CA 95070 APN: # 389-18-049 TR#:748 SAN TOMAS ORCHARDS BLK 9 LOT 64 LOT SIZE:10,001 SF (MIN. 10,000 SF) YEAR BUILT: 1952 MINIMUN LOT WIDTH 80 FT / LOT WIDTH 80.01 FT PROPOSED STRUCTURE FIRST FLOOR MAIN HOUSE 2,853 SF 2 CAR GARAGE 496 SF ADU ON GROUND FLOOR 530 SF GROSS BUILDING AREA 3,879 SF REAR PORCH 310 SF BUILDING NOTES: 1. ALL WORK CONNECTED WITH THIS PROJECT SHALL BE DONE IN A PROFESSIONAL MANNER IN ACCORDANCE WITH THE TRADITIONALLY AND LEGALLY DEFINED "BEST ACCEPTED PRACTICE" OF THE TRADE INVOLVED. ADDITIONALLY, ALL WORKSHAL COMPLY WITH APPLICABLE CODES & TRADE STANDARDS WHICH GOVERN EACH PHASE OF WORK, INCLUDING THE: CITY OF SARATOGA Local Ordinances . 2019 CALIFORNIA FIRE CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA EXISTING BUILDING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA GREEN BUILDING CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 BUILDING ENERGY EFFICENCY STANDARDS Rebuild a one-story home with 4 bedrooms and 4.5 baths measuring 2,853 square feet along with 496 square feet attached garage and attached ADU with 1 bedroom and 1 bath measuring 530 square feet at 13251 Quito Road, Saratoga,CA. AMERICAN SOIL TESTING & ENGINEERING INC 735 E. BROKAW RD SAN JOSE, CA 95112 US (408)559-6400 www.americansoiltesting.com info@americansoiltesting.com Utopian Landscapes Landscape Architecture & Design Services / Justin Ware (209) 954-9065 Office (209) 423-9424 Mobile www.utopianlandscapes.net House CAD Drafting / Adolfo M Martinez 24301 Southland Dr. Suite 605C Hayward CA 94545 Ph: (510) 828-3033 adolfo@housecadrafting.com 1,128 sf existing one story house and 450 sf two car garage to be demolished. Sheet List Sheet Number Sheet Name A100 PROJECT INFORMATION & DATA A101 EXISTING SITE PLAN A101.1 STREET SCAPE PLAN AND VIEWS A101.2 NEIGHBORHOOD PICTURES A102.0 EXISTING HOUSE / DEMOLITION PLAN A102.1 PROPOSED FLOOR LAYOUT A102.2 PROPOSED ROOF PLAN A103 PROPOSED ELEVATIONS A103.1 PROPOSED ELEVATIONS AND BUILDING SECTIONS A105 BUILDING SECTIONS C1 EXISTING CONDITIONS MAP & DEMOLITION PLAN C1.1 BOUNDARY AND TOPOGRAPHIC SURVEY C2 PRELIMINARY GRADING, DRAINAGE & UTILITY PLAN RDG-1 MATERIAL BOARD X1.1 FLOOR OVERALL scale:1 3D VIEW NORTH EAST 3-Side Existing 6'-0" Solid Fence -Pressure Treated plus 2' Lattice on top of solid fence. Not shown by clarity 1 “Disposition and treatment of storm water will comply with the National Pollution Discharge Elimination System (“NPDES”) Standards and implementation standards established by the Santa Clara Valley Urban Runoff Pollution Prevention Program”1 All new/upgraded utilities shall be installed underground. a. Contractor / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement these plans.” b. Construction site shall be enclosed by 6’opaque fence at all times during construction. c. No Construction material, equipment, portable toilets, trash containers, or debris shall be placed in the public right-of-way. d. A trash container shall be maintained on site at all times and debris on site which could otherwise blow away, shall be regularly collected and placed in container. e. All construction debris (wood scraps and other debris, which cannot blow away) shall be piled within the property lines of the project in a neat and safe manner. f. The project shall have a signage viewable from the public street that indicates the hours of construction as: Mon-Fri from 7:30 am to 6 pm, Saturdays from 9am to 5 pm. g. Prior to the commencement of any earthwork/grading activities, the applicant / owner shall arrange a pre-construction meeting. The meeting shall include the City of Saratoga Grading Inspector, the grading contractor and the project soils engineer. The applicant / owner shall arrange the pre-construction meeting at least 48 hours prior to the start of any earthwork/grading activities. h. Applicant / Owner shall maintain the streets, sidewalks and other public right of way in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed from the public property. All adjacent property, both public and private, shall be maintained in a clean, safe and usable condition. i. All grading and earthwork activities shall conform to the approved plans and specifications. All grading and earthwork activities shall be observed and approved by the soils engineer. The soils engineer shall be notified at least 48 hours prior to any grading or earthwork activities. Unobserved or unapproved work shall be removed and replaced under observation of the project soil engineer. j. Prior to final inspection for any building or structure, the Geotechnical Engineer or Civil Engineer who prepared the soil investigation shall issue a final report stating the completed pad, foundation, finish grading, and associated site work substantially conform to the approved plans, specifications, and investigation. k. The geotechnical engineer of record shall provide observation during grading and drainage operations. l. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. m. Prior to the Building Department final, all drainage, grading, and landscaping of the site shall be completed. CONSTRUCTION NOTES No. Description Date 1Planning D.R.09-03-21 167 WH 98.21 98.50 99.14 98.04 97.66 LAWN LAWN LAWN LAWN LAWN LAWN FCE WOOD TEE LAWN GATEPOST GATEPOSTCTR DOOR 60" CTR 32"GAR FF THRESHOLD BCOR OH WIRE LAWN LAWN LAWN LAWN LAWN LAWN LAWNFCE WOOD CORFCE WOOD COR LAW N LAWNLAWN LAWN LAWN DRIPLINE DRIPLINE DWWALL DWWALL F CE WOOD E ND FCE OOD BEG FCE WOOD END FCE WOOD TEE GATEPOST CTR DOOR 36"FF STEPSTEP M A IL B O X T.33" REDWOOD 15.94'15.91' 25.91'25.81' 16.03' 16.07'17.85' 17.88' 44.72'44.93' 0.23'(to fence) 0.25'(to fence) 0.44'(to fence)TelephoneElectric 6 " W h ite St ripe 6" White S tripe PGE Vlt. WM Concrete Sidewalk Concrete Driveway Concrete Walkway Existing Building AC Unit (on wall) Concrete Patio Elec. Meter Gas Meter Concrete PorchJP 9 7 .9 8 99.81 99.62 99.17 99.04 98.38 98.08 98.26 97.60 97.99 98.0197.93 98.52 98.70 99.24 98.41 99.9299.2198.569 8 .4 8 98.5498.43 98.42 98.20 98.36 98.19 98.2098.42 98.3098.8098.87 99.84 99.79 99.08 98.86 99.43 98.74 98.53 98.93100.4810 0 .15 99.84 98.41 98.99 9 8 .8 9 98.86 99.08 98.84 98.66 97.19 96.679 6 .5 8 9 6 .5 1 96.63 9 7 .13 97.6397.67 97.91 97.94 T.16" T.14" T.17" T.9"MAGNOLIA 96.90 97.17 T.CLUSTER 96.58 96.27 9 6 .5 3 96.97 96.96 97.3097.8897.70 98.3898.43 99.83 100.00 99.72 97.9497.9697.91 98.20 98.2998.21 98.31 98.2798.5898.9598.95 98.5498.1298.14 98.0897.92 97.5898.0898.0998.1298.0498.05 97.97 98.03 9 8 .0 0 98.4599.8698.2997.98 9 7 .9 598.09 96.8797.68 97.47 96.7296.4197.29 97.16 96.33 96.01 96.3196.3797.0997.4197.75 97.8297.9 6 97.9397.8897.55 97.78 97.61 97.16 96.83 97.06 96.7796.28 95.88 N02°23'30"W 80.01'N87°36'30"E 125.00'N02°23'30"W 80.01'N87°36'30"E 125.00'WD DW A102.03 A102.0 A102.0 A102.0 5 4 2 17' - 3" 16' - 3"25' - 10"45' - 0"125.0'125.0'4" / 1'-0" 4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"NS W E (E) GAS METER (E) ELEC METER 4" / 1'-0" 4" / 1'-0"4" / 1'-0"38' - 7" 21' - 3"29' - 10"80.01 '125.0'125.0'NS W E 25' - 0"8' - 0" 8' - 0"A103 1 A1033 A103 2 A103.1 4 (E) GAS METER (E) ELEC METER RDG-1 125' - 0"19' - 5"REAR PORCH 13251 QUITO ROAD25' - 3"SIDE STBCKSIDE STBCK Minimum SetbackMinimum SetbackHVAC Condensor Garbage Bim Recycle Bim Green Bin A101.1 2 34' - 5"Bark wwwwwww.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 551-580-3814 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/8" = 1'-0"01/31/2022 8:19:12 PMA101EXISTING SITE PLAN022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070scale:1/8" = 1'-0"1 Existing Site Plan and Demolition scale:1/8" = 1'-0"2 PROPOSED SITE PLAN scale:3 SOUTH EAST VIEW scale:4 NORTH WEST VIEW scale:5 NORTH EAST VIEW PRIOR TO FOUNDATION INSPECTIONS BY THE CITY, THE LLS OF RECORD SHALL PROVIDE A WRITTEN CERTIFICATION THAT ALL BUILDING SETBACKS ARE PER THE APPROVAL PLANS. EXISTING HOUSE AND GARAGE TO BE DEMOLISHED SEE ADDITIONAL INFORMATION ON C1 EXISTING CONDITIONS MAP AND DEMOLITION PLAN ADU MAIN HOUSE TWO CAR GARAGEExisting 6'-0" Solid Fence -Pressure Treated plus 2' Lattice on top of solid fence1 No. Description Date 1Planning D.R.09-03-21 SUBMITTED TO CDD ON 1/12/22 168 WD DW 80.01'125.0'125.0'NS W E 25' - 0"8' - 0"8' - 0" 8' - 0"8' - 0"25' - 0"7' - 4"14' - 0"19' - 5"REAR PORCH 13251 QUITO ROAD25' - 3"Minimum SetbackHVAC Condensor 14' - 0" 15' - 0" 1' - 6" 12' - 0" 13265 QUITO ROAD 13237 QUITO ROAD ONE STORYONE STORY ONE STORY ONE STORY ONE STORY ONE STORY 16' - 0"16' - 0"9' - 6"11' - 6"Average Elevation 98.9'22' - 3"15' - 7"www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 551-580-3814 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x As indicated 01/31/2022 8:19:20 PMA101.1STREET SCAPE PLAN AND VIEWS022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070scale:1/16" = 1'-0"1 PROPOSED STREET SCAPE scale:1/8" = 1'-0"2 STREET SCAPE VIEW 13264 13250 13236 132231325113265 13500 McCoy Ave Southwest YMCA PIC 1PIC 9 PIC 10PIC 2 PIC 3 PIC 13 PIC 12 PIC 11 PIC 6PIC 7PIC 8 PIC 14 No. Description Date 169 www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 01/12/2022 6:56:15 PMA101.2NEIGHBORHOOD PICTURES022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070PIC 1 13251 Quito Road PIC 2 PIC 7 PIC 8 PIC 9 PIC 3 PIC 6 13236 McCullochAve 13250 McCullochAve 13264 McCullochAve 13278 McCullochAve PIC 10 PIC 11 PIC 12 PIC 13 PIC 14 No. Description Date 170 WH GATEPOSTCTR 32"GAR FF OH WIRE GATEPOST CTR DOOR 36"FF STEPSTEP 17.85' 17.88' Concrete Walkway Existing Building AC Unit (on wall)Elec. Meter Gas Meter Concrete Porch9 7 .9 898.0197.93 98.41 98.4298.20 98.2098.42 98.8098.87 98.99 9 8 .8 9 99.08 98.6698.43 99.83 100.00 99.72 97.9497.9697.91 98.20 98.2998.21 98.31 98.2798.5898.9598.95 98.1298.1498.0898.0998.1298.0498.05 98.45 98.2997.98 97.9598.0920' - 2"4' - 0" 24' - 2" 22' - 4"34' - 0"33' - 8"16' - 6"8' - 9"22' - 11"10' - 9"2' - 11"11' - 6"12' - 5"10' - 6"2' - 1"6' - 0"12' - 0"11' - 2"16' - 1"7' - 0"5' - 0" 10' - 6" 7' - 0"1' - 5" 1' - 10" 6' - 8"5' - 7"19' - 3" Bedroom 1 Bedroom 2 Closet Closet Kitchen Hall Bathroom Bedroom 3 Dining Room Living Room Foyer 11' - 7" 13' - 1"11' - 1"12' - 2"2' - 6"6' - 5"12' - 8"3' - 9"6' - 0"3' - 6"12' - 2"3' - 4"11' - 2"7' - 5"19' - 3"22' - 0" N 2 Car Garage T.P (1) 111' -0" Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" T.P (1) 111' -0" Ground 98' -0" - 112' -8"1' - 8"13' - 0"E-1st F.F. 100' -0"14' - 8"Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/4" = 1'-0"01/12/2022 6:56:16 PMA102.0EXISTING HOUSE / DEMOLITIONPLAN022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070scale:1/4" = 1'-0"1 EXISTING HOUSE TO BE DEMOLISHED Concrete Patioscale:1/4" = 1'-0"2 EXISTING EAST VIEW scale:1/4" = 1'-0"3 EXISTING NORTH VIEW scale:1/4" = 1'-0"4 EXISTING SOUTH VIEW scale:1/4" = 1'-0"5 EXISTING WEST VIEW No. Description Date 171 WD DW A1033A103.1 4 8' - 11" Bath 1 ADU Hallway 10' - 10" 8' - 0" 2 Car Garage 15' - 5"16' - 2"14' - 7" 21' - 11"25' - 4"16' - 6" 63' - 9"1' - 6"13' - 2"8' - 9"6' - 3"8' - 0"3' - 10"6' - 9"16' - 11"65' - 2"11' - 6"10' - 2" 8' - 0" Bedroom 2 Bath 2 48' - 7"26' - 0"74' - 7"9' - 6" LIVING ADU 007 12 4' - 3"Master Bedroom 5 15' - 10"5' - 6"21' - 1"3' - 7"14' - 1"Bath 4 7' - 4"4' - 5"10' - 11"4' - 3"9' - 6"12' - 6"2' - 9" 3' - 10" 5' - 4"8' - 2"6' - 1"3' - 0" 3' - 7"11' - 11" 1' - 4"9' - 2"1' - 0"9' - 2"1' - 4" 20' - 11"21' - 8"8' - 10"24' - 7"24' - 7"18' - 10"6' - 2"8' - 0"12' - 10" 8' - 10" 17' - 9"4' - 0"20' - 0"12' - 9"5' - 6"15' - 4"3' - 0"1' - 0"11" 17' - 0"8' - 0"5' - 1"5' - 2"5' - 11"6' - 9"2' - 9"7' - 3"5' - 2"2' - 11"ADU Bedroom 1 12' - 6"6' - 7"3' - 4"10' - 9"14' - 5" 25' - 4" 63' - 10" 5' - 3"10' - 6"10' - 6"1' - 4" 11' - 7"13' - 5"6' - 6"5' - 6" 002 021 004 19 010 015 014 009 26 016 003 020 17 15 16 13 14 09 006 001 05 1 A105 2 A105 3 A105 EQ EQ 4' - 1"5' - 5" 02 01 028 030 1 A103.1 025 1' - 0"3' - 4"EQEQ5' - 2" 3' - 5"6' - 6"4' - 0"4' - 1" 8' - 2"4' - 3"6' - 8"9"9"8' - 1"8' - 1"1' - 6"8" 3' - 5" AC UNIT Rcycl Grbg Green 1HR FIRE RATED WALL FNDT TO ROOF Cl. 66 64 65 70 68 054 044 045 048 047 053 032 033 0292' - 4"9' - 3"12' - 8"3' - 7"Bedroom 4 Closet Hallway Cl. W.C. Powder Cl. Entry Cntrl rm Bedroom 3 046 11' - 3"8' - 7"6' - 2"16' - 6" 8' - 2" 8"24' - 0"1' - 1"3' - 3"2' - 9"4' - 7"10' - 3"4' - 1"8' - 0" 2' - 0"5' - 7"10' - 3"3' - 10"2' - 8"5' - 4" 3' - 0"24' - 8"17' - 3"21' - 11"4' - 1"2' - 6"5' - 6"12' - 11"12' - 2"9' - 5"04320Min. Fire Rtd 2' - 11"6' - 7"27 2' - 9" 049 20 Height Ceiling 11'-0" www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/4" = 1'-0"01/12/2022 6:56:17 PMA102.1PROPOSED FLOOR LAYOUT022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070New Window Schedule Mark Width Height Family Phase Created U Value Comments 01 5' - 0" 7' - 0" Window-Fixed New Construction 02 5' - 0" 7' - 0" Window-Fixed New Construction 05 4' - 0" 4' - 0" Window-Sliding-Double New Construction 09 8' - 0" 6' - 0" Window-Sliding-Four New Construction 12 8' - 0" 6' - 0" Window-Sliding-Four New Construction 13 2' - 6" 5' - 0" Window-Single-Hung New Construction 14 2' - 6" 5' - 0" Window-Single-Hung New Construction 15 2' - 0" 5' - 0" Window-Single-Hung New Construction 16 5' - 0" 2' - 0" Window-Awning-Single New Construction 17 2' - 0" 2' - 0" Window-Awning-Single New Construction 19 2' - 0" 5' - 0" Window-Single-Hung New Construction 20 1' - 8" 5' - 0" Window-Single-Hung New Construction 23 7' - 10" 2' - 4" Window-Fixed-Arch-Top New Construction 26 1' - 8" 6' - 0" Window-Single-Hung New Construction 27 1' - 8" 6' - 0" Window-Single-Hung New Construction 29 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 30 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 31 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 32 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 34 1' - 10" 3' - 10" Window-skylight-VELUX_FS-deck_mounted-fixed (1) New Construction 35 1' - 10" 3' - 10" Window-skylight-VELUX_FS-deck_mounted-fixed (1) New Construction 36 1' - 10" 3' - 10" Window-skylight-VELUX_FS-deck_mounted-fixed (1) New Construction 39 1' - 10" 3' - 10" Window-skylight-VELUX_FS-deck_mounted-fixed (1) New Construction 47 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 48 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 50 1' - 6" Window-Louvers New Construction 51 1' - 6" Window-Louvers New Construction 57 9' - 0" 1' - 6" Window-Fixed New Construction 58 1' - 6" Window-Louvers New Construction 62 3' - 0" 2' - 0" Window-Sliding-Double New Construction 63 4' - 0" 4' - 0" Window-Sliding-Double New Construction 64 2' - 0" 5' - 0" Window-Single-Hung New Construction 65 6' - 0" 5' - 0" Window-Sliding-Double New Construction 66 3' - 6" 2' - 6" Window-Awning-Single New Construction 67 0" 0" Window-skylight-VELUX_TGR_014-tubular-daylighting-rigid New Construction 68 9' - 0" 1' - 6" Window-Fixed New Construction 69 2' - 0" 2' - 0" Window-Sliding-Double New Construction 70 5' - 0" 5' - 0" Window-Sliding-Double New Construction 71 1' - 6" Window-Louvers New Construction 72 1' - 10" 3' - 10" Window-skylight-VELUX_FS-deck_mounted-fixed (1) New Construction 73 9' - 0" 2' - 0" Window-Fixed New Construction 74 9' - 0" 2' - 0" Window-Fixed New Construction New Door Schedule Mark Width Height Family Phase Created Function Comments 001 4' - 0" 8' - 0" Door-In_Swing-Milgard-Tuscany_Series-French_S tyle-1_Panel_Dual_Sidelite New Construction Exterior 002 9' - 0" 8' - 0" Door-Garage-Flush_Panel New Construction Exterior 003 9' - 0" 8' - 0" Door-Garage-Flush_Panel New Construction Exterior 004 3' - 0" 8' - 0" Door-Exterior-Single-Entry-Half Flat Glass-Wood_Clad New Construction Exterior 006 6' - 0" 8' - 0" Door-Sliding-Milgard-Tuscany_Series-2_Panel New Construction Exterior 007 19' - 0" 8' - 0" Door-Sliding-Milgard-Tuscany_Series-4_Panel New Construction Exterior 009 2' - 6" 8' - 0" Door-Interior-Single-Pocket-2_Panel-Wood New Construction Interior 010 3' - 0" 8' - 0" Single-Flush New Construction Interior 014 2' - 6" 8' - 0" Single-Flush New Construction Interior 015 2' - 8" 8' - 0" Single-Flush New Construction Interior 016 4' - 0" 8' - 0" Bifold-4 Panel New Construction Interior 020 2' - 8" 8' - 0" Door-Interior-Single-Pocket-2_Panel-Wood New Construction Interior 021 2' - 8" 8' - 0" Single-Flush New Construction Interior 025 3' - 6" 6' - 8" Double-Flush-Double-Flush.rfa New Construction Interior 028 2' - 6" 8' - 0" Single-Flush New Construction Interior 029 5' - 0" 8' - 0" Door-Sliding-Milgard-Tuscany_Series-2_Panel New Construction Exterior 030 5' - 0" 8' - 0" Door-Interior-Double-Pocket-2_Panel-Wood New Construction Interior 032 2' - 6" 8' - 0" Single-Flush New Construction Interior 033 6' - 0" 6' - 8" Sliding-Closet New Construction Interior 034 2' - 6" 8' - 0" Track-Sliding-Krownlab-Ragnar New Construction 035 2' - 4" 8' - 0" Single-Flush New Construction Interior 039 8' - 0" 7' - 0" Door-Garage-Flush_Panel New Construction Exterior 040 3' - 0" 6' - 8" Single-Decorative 2 New Construction Exterior 041 1' - 0" 7' - 0" Door-Exterior-Side_Lite-Full Flat Glass-Wood_Clad New Construction Exterior 042 1' - 0" 7' - 0" Door-Exterior-Side_Lite-Full Flat Glass-Wood_Clad New Construction Exterior 043 3' - 0" 8' - 0" Single-Flush New Construction Interior 044 2' - 8" 8' - 0" Single-Flush New Construction Interior 045 4' - 0" 8' - 0" Sliding-Closet New Construction Interior 046 2' - 4" 8' - 0" Single-Flush New Construction Interior 047 2' - 6" 8' - 0" Single-Flush New Construction Interior 048 4' - 0" 8' - 0" Door-Interior-Double-Pocket-2_Panel-Wood New Construction Interior 049 3' - 0" 8' - 0" Door-Exterior-Single-Entry-Half Flat Glass-Wood_Clad New Construction Exterior 053 2' - 6" 8' - 0" Track-Sliding-Krownlab-Ragnar New Construction 054 2' - 8" 8' - 0" Single-Flush New Construction Interior 055 2' - 8" 8' - 0" Single-Flush New Construction Interior scale:1/4" = 1'-0"1 Proposed Floor plan No. Description Date 172 A1033A103.1 4 1 A105 2 A105 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3 A105 1 A103.1 [No Slope] 3" / 1'-0"3" / 1'-0" 3" / 1'-0" 3" / 1'-0"1' - 0"1' - 0"3' - 0" 1' - 0" DS DS DS DS DS DS DS DS DSDS DSDS 3' - 4"3' - 6" 35 36 34 30 39 29 31 47 32 482' - 4"67 72 2" / 1'-0"3" / 1'-0"1' - 6"6' - 8"www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/4" = 1'-0"01/12/2022 6:56:18 PMA102.2PROPOSED ROOF PLAN022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070scale:1/4" = 1'-0"1 Proposed Roof Plan No. Description Date 173 T.P (1) 111' -0" Ground 98' -0" E-1st F.F. 100' -0" 001 002003 16' - 6"11' - 0"1 A105 4' - 3"1' - 0"2' - 6"23 02 01 12' - 3"2' - 4" 9"9"3' - 6"R.R. 121' -2"2' - 0"10' - 2"18'0" Above average grade 26'0" Above average grade 1 1 Average Elevation 98.9'22' - 3"15' - 7"15' - 7"13251 T.P (1) 111' -0" - 112' -8" E-1st F.F. 100' -0" 12 007 09 1 A105 11' - 0"10' - 2"Porch Roof R.R. 121' -2"9' - 0"9' - 0"1' - 8"T.P (1) 111' -0" Ground 98' -0" E-1st F.F. 100' -0" 19 17 16 15 14 13 2 A105 3 A105 1 A103.1 3' - 0"9' - 0"16' - 6"3' - 6"11' - 0"2' - 0"R.R. 121' -2" 99' - 4"98' - 0" 18'0" Above average grade 26'0" Above average grade1 1 18' - 0"8' - 0"22' - 3"049 20 029 www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/4" = 1'-0"01/12/2022 6:56:33 PMA103PROPOSED ELEVATIONS022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 950703 2 1 4 5 6 7 9 8 10 scale:1/4" = 1'-0"1 NEW EAST VIEW scale:1/4" = 1'-0"2 N-West View scale:1/4" = 1'-0"3 N- North View EXTERIOR ELEVATION NOTES: 1. 7/8" Cement plaster, 3 coats o/ metal lath o/ layers of "D" building paper o/ ply sheathing (LaHabra , Pacific sand x97 base 200 ) match with existing. 2. Roofing: Tesla Solar roof . Tesla Solar Roof carries a UL 790 Class A fire rating. 3. Windows: 'Marvin Fiberglass, color blach. 4. Windows Trims: Cement plaster o/ 1x6 foam trim, color to match building. 5. Weep Screed: @+4" min above finished grade or +2" above conc. Porch. 6. Fascia Gutter: G.I. Fascia gutter painted. 7. Fascia Board painted, color same as gutter. 8. Window Sill: Cement plasters o/ foam trim, color to match building. 9. G.I. wall to roof Flashing painted. 10. Address shall be internally lit during non daylight hours . Switching shall be controlled by the clock or photo sensor. Address numbers shall read from left to right with 6" hight minimun on a contrastting background. 11. El Dorado Stone 30"wainscoat. Rustic Ledge stone, Color Sequoia. No. Description Date 1 Planning D.R. 09-03-21 Average Elevation 98.9' 174 T.P (1) 111' -0" Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" 006 004 05 2 A105 3 A105 1 A103.1 3' - 0"3' - 6"2' - 0"11' - 0"10' - 2"4' - 8"3' - 4"13' - 3"2' - 0"23' - 2"R.R. 121' -2"8' - 0"Average Elevation 98.9' T.P (1) 111' -0" Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" 1 A105 15' - 0"M. Bathroom 5Great RoomDining Room11' - 0"10' - 6"1' - 3"R.R. 121' -2" Living Room www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/4" = 1'-0"01/12/2022 6:56:45 PMA103.1PROPOSED ELEVATIONS ANDBUILDING SECTIONS022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070scale:1/4" = 1'-0"4 N- South View EXTERIOR ELEVATION NOTES: 1. 7/8" Cement plaster, 3 coats o/ metal lath o/ layers of "D" building paper o/ ply sheathing (LaHabra , Pacific sand x97 base 200 ) match with existing. 2. Roofing: Tesla Solar roof . Tesla Solar Roof carries a UL 790 Class A fire rating. 3. Windows: 'Marvin Fiberglass, color blach. 4. Windows Trims: Cement plaster o/ 1x6 foam trim, color to match building. 5. Weep Screed: @+4" min above finished grade or +2" above conc. Porch. 6. Fascia Gutter: G.I. Fascia gutter painted. 7. Fascia Board painted, color same as gutter. 8. Window Sill: Cement plasters o/ foam trim, color to match building. 9. G.I. wall to roof Flashing painted. 10. Address shall be internally lit during non daylight hours . Switching shall be controlled by the clock or photo sensor. Address numbers shall read from left to right with 6" hight minimun on a contrastting background. 11. El Dorado Stone 30"wainscoat. Rustic Ledge stone, Color Sequoia. 3 2 1 4 5 6 7 9 8 scale:1/4" = 1'-0"1 Section 5 No. Description Date 175 T.P (1) 111' -0" Ground 98' -0" E-1st F.F. 100' -0" 2 A105 11' - 0"3 A105 15' - 0"1 A103.1 Great Room 11' - 0"R.R. 121' -2"9' - 6"11' - 4" Foyer Great Room T.P (1) 111' -0" Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" 1 A105 Kitchen Bath 2 Bedroom 2Foyer 1' - 8"11' - 0"2' - 0"R.R. 121' -2"4' - 11"18' - 3"23' - 2"Laundry / Ptry4' - 9"5' - 6" T.P (1) 111' -0" Ground 98' -0" - 112' -8" E-1st F.F. 100' -0" 1 A105 1' - 3"12' - 3"3' - 3"12' - 8"11' - 0"2' - 0"1' - 8"23' - 2"8' - 6"R.R. 121' -2"10' - 6"LIVING ADU Bath2 Car Garage www.HouseCADrafting.com Scale Project number Date Drawn by Checked by Designer : Adolfo M Martinez Address : 24301 Southland Dr Suite 605D Hayward CA 94545 Phone : 510-828-3033 e-mail : adolfo@housecadrafting.com Owner: Jawwad Sultan Khan 13251 Quito Road Saratoga CA 95070 Phone: 408-398-2961 e-mail: jsk2564@gmail.com Structural Engineer: - Phone: x e-mail: x Soil Engineer: American Soil Testing and Engineering Inc. 735 E Brokaw Road San Jose, CA 95112- Phone: 408-559-6400 www.americansoiltesting.com e-mail: x 1/4" = 1'-0"01/12/2022 6:56:47 PMA105BUILDING SECTIONS022-2020JAWWAD SULTAN KHANIssue Date Author CheckerKHAN FAMILY RESIDENCE13251 QUITO ROADSARATOGA CA 95070scale:1/4" = 1'-0"1 Section 1 scale:1/4" = 1'-0"2 Section 2 scale:1/4" = 1'-0"3 Section 3 No. Description Date 176 177 REPORT TO THE PLANNING COMMISSION Meeting Date: February 9, 2022 Application: PDR21-0016/ARB21-0069 Address/APN: 19701 Via Grande Drive/393-19-019 Property Owner: Rajesh Chaganti and Sirisha Uppaluri From: Debbie Pedro, Community Development Director Report Prepared By: Nicole Johnson, Senior Planner 178 Report to the Planning Commission 19701 Via Grande Drive -Application # PDR21-0016/ARB21-0069 February 9, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a new 4,707 square foot two story residence which includes an attached ADU (maximum height 25’6”). Six protected trees are proposed for removal. STAFF RECOMMENDATION Adopt Resolution No. 22-005 approving the project subject to conditions of approval included in Attachment 1. Pursuant to City Code Section 15-45.060(a)(1) and (3), approval by the Planning Commission is required as the project is a new two story home over 18’ in height. PROJECT DATA Gross/Net Site Area: 13,054 sq. ft. gross/net (.29 acres) Average Site Slope: Less than 10% General Plan Designation: M-12.5 (Medium Density Residential) Zoning: R-1-12,500 (Single Family Residential) Proposed Allowed/Required Site Coverage Residence w/Garage ADU Driveway/Walkways/Patios/Porch Total Proposed 3,264 sq. ft. 442 sq. ft. 3,470 sq. ft. 7,176 sq. ft. (54%) 7,897 sq. ft. (60%) * Floor Area Residence Garage ADU Total Floor Area 3,603 sq. ft. 662 sq. ft. 442 sq. ft. 4,707 sq. ft.** 4,268 sq. ft.* plus 441 sq. ft. over allowable for ADU** Height 25’6” 26’ Setbacks Front: Left Side: Right Side Rear: 1st Floor 2nd Floor 25.65’ 25.69’ 10’ 27.9’ 10’ 27.9’ 35’ 35’ 1st Floor 2nd Floor 25’ 25’ 10’ 15’ 10’ 15’ 30’ 40’ Grading No Grading Proposed No grading limit in the R-1-12,500 zoning district *Includes onetime 10% for deed restricted ADU Per City Code Section 15-56.025 (2) ** Includes onetime 441 sq.ft. over allowable floor area allowance for ADU Per City code Section 15-56.025 (5) (b) SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The project site is located at 19701 Via Grande Drive in the R-1-12,500 (Single Family Residential) zoning district. The 13,054 square foot site is relatively level. Surrounding uses on all sides include one-story single-family homes on similar sized parcels. 179 Report to the Planning Commission 19701 Via Grande Drive -Application # PDR21-0016/ARB21-0069 February 9, 2022 Page | 3 Project Description The architectural style of the project can best be described as modern. The 2,572 square foot first floor consists of an entry, office, living room, bedroom suite, master suite, covered porch and kitchen and a 662 square foot three car garage. There is also a 441 square foot attached ADU which is accessed via the main residence and an exterior access. The second floor consists of 220 square feet of usable attic space greater than 5’ tall and two bedrooms and a bathroom totaling 781 square feet. The applicant has provided a color and materials board (Attachment 5). Below is a list of the proposed exterior materials. Detail Colors/Materials Exterior Distant Grey/Stucco with stone veneer and wood siding Windows / Trim Black/Composite Front door/Garage door Bronze/Metal & Glass Roof Charcoal/Standing seam metal Trees The project arborist inventoried a total of eleven protected trees on the property. The City Arborist has made the findings to remove six protected trees are proposed for removal, a Japanese maple and Carolina laurel cherry in the front yard, and four silver dollar gum trees along the west property line. A description of the trees to be preserved and the tree protection plan are included in the Arborist Report. (Attachment 2) Landscaping The installation of front yard landscaping is required prior to building permit final inspection. The project includes a condition of approval that landscaping is to be installed per City Code Section 15- 12.095. FINDINGS Design Review The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the building site is relatively level and no grading is required to construct the project. The site development is appropriate to the site’s natural constraints with single family homes around it. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees 180 Report to the Planning Commission 19701 Via Grande Drive -Application # PDR21-0016/ARB21-0069 February 9, 2022 Page | 4 approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the City Arborist has made the findings to remove six protected trees. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that no community view sheds are in the vicinity of the project. d. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the proposed residence complies with the maximum height limitation of 26 feet allowable for residential structures; the building has varying architectural forms and exterior materials to break up the appearance of mass, the building setbacks comply with those required for the R-1-12,500 zoning district. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood and streetscape. This finding may be made in the affirmative in that the project includes a condition of approval that front yard landscaping is to be installed prior to building department final inspection. Staff will ensure that this landscaping is complimentary to the neighborhood and streetscape. The City Code requires that at least 50% of the front setback area be landscaped. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding may be made in the affirmative in that the home is similar in mass and height with the homes in the neighborhood and will not cast shadows on the adjacent properties which could impair the adjacent property owner’s opportunity to utilize solar energy. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk and avoiding unreasonable interference with privacy and views as detailed in the findings above. 181 Report to the Planning Commission 19701 Via Grande Drive -Application # PDR21-0016/ARB21-0069 February 9, 2022 Page | 5 h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. Neighbor Notification and Correspondence The Community Development Department mailed public notices to property owners within 500 feet of the site. In addition, the public hearing notice and description of the project was published in the Saratoga News. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single-family residence and small structures in a residential area. The project, as proposed, is for the construction of a new residence in a suburban, residential area. ATTACHMENTS 1. Resolution No. 22-005 2. Arborist Report dated 12/22/2021 3. Neighbor Notification Forms 4. Story Pole Certification 5. Material Board 6. Project Plans 182 RESOLUTION NO: 22-005 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0016 AND ARBORIST REVIEW ARB21-0069 19701 VIA GRANDE DRIVE (APN 393-19-019) WHEREAS, on July 1, 2021 an application was submitted by Rajesh Chaganti and Sirisha Uppaluri requesting Design Review approval for a new 4,707.8 square foot two story residence with an ADU (maximum height 25’6”). Six protected trees are proposed for removal. The site is zoned R-1-12,500 with a General Plan Designation of Medium Density Residential Low Density (M- 12.5). WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA) and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on February 9, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints; the porch and entry are in scale with other structures in the neighborhood. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. 183 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 2 Section 5: The City of Saratoga Planning Commission hereby approves PDR21- 0016/ARB21-0069 for 19701 Via Grande Drive (APN 393-19-019), subject to the Findings and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 9th day of February 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Anjali Kausar Chair, Planning Commission 184 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0016/ARB21-0069 19701 VIA GRANDE DRIVE (393-19-019) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. 185 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 4 In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. COMMUNITY DEVELOPMENT DEPARTMENT 5. PERMANENT CONDITION OF APPROVAL (Deed Restriction) The owner shall record a deed restriction satisfactory to the Community Development Director restricting the rental of the accessory dwelling unit to only households that qualify as low, very-low, or extremely-low income households as those terms are defined in the most recent Santa Clara County Housing and Urban Development Program Income Limits. In the event that the most recent such report is more than five years old, the rental income limits of the accessory dwelling unit shall be in accordance with the definitions set forth in Health and Safety Code section 50079.5, 50105, and 50106 as those sections exist as of the effective date of this restriction. “Rental” means any agreement whereby the occupant(s) of the accessory dwelling unit make any payment in consideration of said occupancy. 6. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Development Plans. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 7. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut-off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 8. In order to comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 9. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. 186 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 5 f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 10. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 11. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency, and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall consider potential damage to roots of protected trees 11. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 12. A locking mailbox approved for use by the U.S. Postal service shall be installed and in compliance with Saratoga Municipal Code section 6-25.030. The mailbox shall be installed prior to final inspection. 13. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 14. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. FIRE DEPARTMENT 15. The owner/applicant shall comply with all Fire Department requirements. 187 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 6 ARBORIST 16. The owner/applicant shall comply with all City Arborist requirements. PUBLIC WORKS/ENGINEERING 17. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 18. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 19. Applicant / Owner shall make the following improvements in the City right-of-way: 20. Remove existing driveway approach and replace with new driveway approach per City Standard Detail 205 & 206. 21. See City of Saratoga Standard Details for removal and new installation. New flow line shall conform to existing flow lines and grade. 22. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 23. All new/upgraded utilities shall be installed underground. 24. Applicant / Owner shall maintain the streets, sidewalks and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 25. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g. landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay-Friendly Landscaping). 26. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing storm water pollution: • Owner shall implement construction site inspection and control to prevent construction site 188 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 7 discharges of pollutants into the storm drains per approved Erosion Control Plan. • The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non-storm water management through all phases of construction (including, but not limited to, site grading, building, and finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. • City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 27. Prior to the commencement of any earthwork/grading activities, the permittee shall arrange a pre-construction meeting. The meeting shall include the City of Saratoga Grading Inspector (408-868-1201), the grading contractor, and the project Soils Engineer. The permittee or representative shall arrange the pre-construction meeting at least 48 hours prior to the start of any earthwork activities. 28. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. 29. Prior to the Building final, all Public Works conditions shall be completed per approved plans. 30. Upon the completion of this project the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the City's building inspector to be properly elevated. Such certification and verification shall be provided to the City’s Floodplain Administrator. 31. Upon completion of the rough grading work and at the final completion of the project the final grading reports are to be submitted to the City per section 16-17.150 of the City Municipal Code. BUILDING DEPARTMENT SUBMITTAL 32. Complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. Arborist report dated December 22, 2021. c. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. d. This signed and dated Resolution printed onto separate construction plan pages. 189 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 8 DESIGN REVIEW FINDINGS PDR21-0016/ARB21-0069 19701 VIA GRANDE DRIVE (393-19-019) The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the building site is relatively level and no grading is required to construct the project. The site development is appropriate to the site’s natural constraints with single family homes around it. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the City Arborist has made the findings to remove six protected trees. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that no community view sheds are in the vicinity of the project. d. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the proposed residence complies with the maximum height limitation of 26 feet allowable for residential structures; the building has varying architectural forms and exterior materials to break up the appearance of mass, the building setbacks comply with those required for the R-1-12,500 zoning district. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood and streetscape. This finding may be made in the affirmative in that the project includes a condition of approval that front yard landscaping is to be installed prior to building department final inspection. Staff 190 19701 Via Grande Drive Application # PDR21-0016/ARB21-0069 February 9, 2022 Resolution #22-005 Page | 9 will ensure that this landscaping is complimentary to the neighborhood and streetscape. The City Code requires that at least 50% of the front setback area be landscaped. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding may be made in the affirmative in that the home is similar in mass and height with the homes in the neighborhood and will not cast shadows on the adjacent properties which could impair the adjacent property owner’s opportunity to utilize solar energy. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk and avoiding unreasonable interference with privacy and views as detailed in the findings above. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable to the project as the site is not considered a hillside lot as the average slope is less than 10% nor will it affect any significant hillside feature or community viewshed. 191 Community Development Department 13777 Fruitvale Avenue Saratoga, CA 95070 www.saratoga.ca.us/171/trees 831.291.1344 CITY OF SARATOGA ARBORIST APPROVAL Conditions of Approval and Tree Protection Plan Prepared by Katelyn Obana, Contract Arborist Application No.PDR21-0016/ARB21-0069 Phone: (831) 291-1344 Address:19701 Via Grande Email: Katelyn.Obana@Davey.com Owner:Rajesh Chaganti & Sirisha Uppaluri APN:393-19-019 Date:December 22, 2021 PROJECT SCOPE: The applicant has submitted plans to demolish an existing house and construct a new 2 story home. Six trees that are protected by City Code are requested for removal to construct the project. PROJECT DATA IN BRIEF: Tree security deposit –Required - $10,700 Tree protection –Required – See Conditions of Approval and attached map. Tree removals –Six trees (Tree #2, #5, #17-20) are approved for removal once building permits and a tree removal permit have been issued. Replacement trees –$14,870 ATTACHMENTS: 1 – Findings and Tree Information 2 – Tree Removal Criteria 3 – Conditions of Approval 4 – Map Showing Tree Protection 1 192 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 Attachment 1: FINDINGS Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. Six tree (#2, #5, & #17-20) has been deemed necessary for removal by the project arborist in order to construct this project. These trees meet the City’s criteria allowing them to be removed and replaced as part of the project, once building division permits and a tree removal permit have been obtained. The table below contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No.Common Name Criteria met Comments 2 Japanese maple 6 & 9 In conflict with design. 5 Carolina laurel cherry 1 Extensive cavities & decay. In decline. 17 Silver dollar gum 6 & 9 In conflict with design. 18 Silver dollar gum 6 & 9 In conflict with design. 19 Silver dollar gum 6 & 9 In conflict with design. 20 Silver dollar gum 6 & 9 In conflict with design. New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15-50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1.Shall include the sections Construction Impacts to Subject Trees, and Tree Protection Specifications & recommendations Sequence from the arborist report by Kurt Fouts revised November 17, 2021; 2.Shall include the Project Data in Brief, the Conditions of Approval, and the Map Showing Tree Protection sections of the Contract City Arborist report dated December 22, 2021. 2 193 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 Attachment 1: TREE INFORMATION Project Arborist:Kurt Fouts Date of Amended Report:November 17, 2021 Number of protected trees inventoried:11 Number of protected trees requested for removal: 6 A table summarizing information about each tree is below. Table 1: Tree information & appraisal values from submitted arborist report revised 11/17/2021. Total Value of Appraised Trees to Remain:$42,800 Appraised Value of Removals:$14,870 Required Security Deposit (25%):$10,700 *Trees #3, #4, #6, #9-16 are outside the limits of disturbance or not protected by the City of Saratoga. 3 194 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 Attachment 2: TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1)The condition of the tree with respect to disease,imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2)The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. (3)The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. (4)The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. (5)The age and number of healthy trees the property is able to support according to good forestry practices. (6)Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7)Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8)Any other information relevant to the public health,safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9)The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. (10)The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. 4 195 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 Attachment 3: CONDITIONS OF APPROVAL 1.Owner, Architect, Contractor:It is the responsibility of the owner, architect and contractor to be familiar with the information in this report and implement the required conditions. 2.Permit: a.Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. b.No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 3.Final Plan Sets: a.Shall include the Construction Impacts to Subject Trees, and Tree Protection Specifications & recommendations Sequence from the arborist report by Kurt Fouts revised November 17, 2021 copied onto a plan sheet. b.Shall include the Project Data in Brief, the Conditions of Approval, and the map showing tree protection sections of the City Arborist report dated December 22, 2021. 4.Tree Protection Security Deposit: a.Is required per City Ordinance 15-50.080. b.Shall be $10,700 for tree(s)#1, #7, & #8. c.Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d.May be in the form of cash, check, or a bond. e.Shall remain in place for the duration of construction of the project. f.May be released once the project has been completed, inspected and approved by the City Arborist. 5.Tree Protection Fencing: a.Shall be installed as shown on the attached map. b.Shall be shown on the Site Plan. c.Tree Protection Fencing shall be installed 10 feet out from the fence along the length of the overhanging canopy. d.Shall be established prior to the arrival of construction equipment or materials on site. e.Shall be established prior to the arrival of construction equipment or materials on site. f.Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. g.Shall be posted with signs saying, “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CONTRACT CITY ARBORIST, KATELYN OBANA (831) 291-1344”. h.Wherever protection is needed outside of fences, unprocessed wood chips, or approved equivalent, shall be placed to the edge of the tree’s canopy and to a depth of 6 inches. i.Call Contract City Arborist, Katelyn Obana at (831) 291-1344 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. j.Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 5 196 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 6.Construction:All construction activities shall be conducted outside tree protection fencing unless permitted as conditioned below. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching for utility installation, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 7.Work inside fenced areas: a.Requires a field meeting and approval from City Arborist before performing work. b.Requires Project Arborist on site to monitor work. 8.Project Arborist: a.Shall be Kurt Fouts unless otherwise approved by the City Arborist. b.Shall visit the site every two weeks during grading, trenching or digging activities and every six weeks thereafter. A letter/email shall be provided to the City after each inspection which documents the work performed around trees, includes photos of the work in progress, and provides information on tree condition during construction. c.Shall supervise any permitted pruning or root pruning of trees on site. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. 9.Tree removal: Trees #2, #5, & #17-20 meet the criteria for removal and may be removed once BOTH a tree permit and building division permits have been obtained. 10.New trees: a.New trees equal to $14,870 shall be planted as part of the project before final inspection and occupancy of the new home. New trees may be of any species and planted anywhere on the property as long as they do not encroach on retained trees. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b.Trees shall be replaced on or off site according to good forestry practices, and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. 11.Damage to protected trees that will be retained: a.Should any protected tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessary number of new trees, some of the value for trees may be paid into the City ’s Tree Fund. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b.Water loving plants and lawns are not permitted under oak tree canopies. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 6 197 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 12.Final inspection: At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the City, call City Arborist for a final inspection. Before scheduling a final inspection from the City Arborist, have the project arborist do an inspection, prepare a letter with their findings and provide that letter to the City for the project file. 7 198 19701 Via Grande City of Saratoga Arborist Review December 22, 2021 Attachment 4:Map Showing Tree Protection: From submitted arborist report revised 11/17/2021 8 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226