Loading...
HomeMy WebLinkAbout10-12-2022 Planning Commission Meeting Agenda PacketSaratoga Planning Commission Agenda – Page 1 of 3 SARATOGA PLANNING COMMISSION REGULAR MEETING OCTOBER 12, 2022 10/12/22 AMENDED AGENDA ITEM 2.1 – APPLICANT REQUESTED ITEM BE POSTPONED TO A DATE UNCERTAIN. 7:00 P.M. - PLANNING COMMISSION REGULAR MEETING This meeting will be entirely by teleconference and will be conducted in compliance with Government Code section 54953(e) of the Ralph M. Brown Act allowing teleconferencing during a proclaimed state of emergency when state or local officials have imposed or recommended measures to promote social distancing. The public will not be able to participate in the meeting in person. During the meeting the Chair will explain the process for members of the public to be recognized to offer public comment. Members of the public view and participate in the meeting by: 1. Using the Zoom website https://us02web.zoom.us/j/82652375945 App (Webinar ID 826 5237 5945) and using the tool to raise their hand in the Zoom platform when directed by the Chair to speak on an agenda item; OR 2. Calling 1.669.900.6833 or 1.408.638.0968 and pressing *9 to raise their hand to speak on an agenda item when directed by the Chair; OR 3. Viewing the meeting on Saratoga Community Access Television Channel 15 (Comcast Channel 15, AT&T UVerse Channel 99) and calling 1.669.900.6833 or 1.408.638.0968 and pressing *9 to raise their hand to speak on an agenda item when directed by the Chair; OR 4. Viewing online at http://saratoga.granicus.com/MediaPlayer.php?publish_id=2 and calling 1.669.900.6833 or 1.408.638.0968 and pressing *9 to raise their hand to speak on an agenda item when directed by the Chair. Members of the public can send written comments to the Commission prior to the meeting by commenting online at www.saratoga.ca.us/pc prior to the start of the meeting. These emails will be provided to the members of the Commission and will become part of the official record of the meeting. ROLL CALL 1. APPROVAL OF MINUTES Action Minutes from the Planning Commission Meeting of September 14, 2022. Recommended Action: Approve Minutes of September 14, 2022 Planning Commission Meeting. 09142022 Draft Minutes ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS Any member of the public will be allowed to address the Planning Commission for up to three (3) minutes on matters not on this agenda. This law generally prohibits the Planning Commission Saratoga Planning Commission Agenda – Page 2 of 3 from discussing or taking action on such items. However, the Planning Commission may instruct staff accordingly regarding Oral Communications. REPORT ON APPEAL RIGHTS If you wish to appeal any decision on this Agenda, you may file an Appeal Application with the City Clerk within fifteen (15) calendar days of the date of the decision. 2. PUBLIC HEARING 2.1 (Continued from September 14, 2022) Application PDR21-0032/ARB21-0120; 20538 Lynde Court (503-52-012); Rajesh & Sunita Lalwani – The applicant is requesting Design Review approval for a new 3,369 square foot two-story single-family home (maximum height 25’- 11”) with a 752 square foot attached accessory dwelling unit. Three protected trees are proposed for removal. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). Staff Contact: Victoria Banfield (408) 868-1212 or vbanfield@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-020 approving the project subject to conditions of approval included in Attachment 1. Staff Report Attachment 1 - Resolution 22-020 Attachment 2 - Arborist Report Attachment 3 - Neighborhood Notification Forms Attachment 4 - Story Pole Certification Attachment 5 - Material Board Attachment 6 - Revised Project Plans Supplemental Memo No. 1 Supplemental Memo No. 2 2.2 Application APTR22-0001; 20196 Franklin Ave (393-39-009); Jiabin Zhao. - The applicant is appealing the denial of permit application TRP22-0227 for the removal of one (1) redwood (Sequoia sempervirens) tree with a trunk diameter of 48 inches which grows in the front yard of the property, Staff contact: Christina Fusco (408) 868-1276 or cfusco@saratoga.ca.us. Recommended Action: Adopt Resolution No. 22-022 denying the appeal. Staff Report Attachment 1 - Resolution No. 22-022 Attachment 3 - Appeal Application APTR22-0001 Attachment 2 - Tree Removal Application TRP22-0227 2.3 Application PDR21- 0023/ARB21-0084; 19518 Glen Una Drive; (510-06-066); Cherine Bassal (Applicant) / Sanjay Banerjee and Anuja Sehgal (Property Owners) – The applicant is requesting Design Review approval for a first and second story addition to an existing 4,241 square foot two story residence for a total floor area of 6,870 square feet. The project will include a detached 430 square foot pool cabana. An existing 501 square foot detached garage will be removed. Four protected trees are proposed for removal which include a Deodar cedar, coast live oak, camphor, and a Ficus. The site is zoned R-1-40,000 with a General Plan Designation of Residential Very Low Density (RVLD. Staff Contact: Christopher Riordan (408) 868-1235 or criordan@saratoga.ca.us. Saratoga Planning Commission Agenda – Page 3 of 3 Recommended Action: Adopt Resolution No. 22-019 approving the project subject to conditions of approval included in Attachment 1. Staff Report Attachment 1 - Resolution No. 22-019 Attachment 2 - Arborist Report dated July 21, 2022 Attachment 3 - Neighbor Comments Attachment 4 - Story Pole Certification Attachment 5 - Materials Board Attachment 6 - ADU Plans Attachment 7 - Project Plans 3. DIRECTOR ITEMS 4. COMMISSION ITEMS 5. ADJOURNMENT CERTIFICATE OF POSTING OF THE AGENDA, DISTRIBUTION OF THE AGENDA PACKET, COMPLIANCE WITH AMERICANS WITH DISABILITIES ACT I, Frances Reed, Administrative Analyst for the City of Saratoga, declare that the foregoing agenda for the meeting of the Planning Commission was posted and available for review on October 7, 2022 at the City of Saratoga, 13777 Fruitvale Avenue, Saratoga, California and on the City's website at www.saratoga.ca.us. Signed this 7th day of October 2022 at Saratoga, California. Frances Reed, Administrative Analyst. In accordance with the Ralph M. Brown Act, copies of the staff reports and other materials provided to the Planning Commission by City staff in connection with this agenda, copies of materials distributed to the Planning Commission concurrently with the posting of the agenda, and materials distributed to the Planning Commission by staff after the posting of the agenda are available on the City Website at www.saratoga.ca.us or available at 13777 Fruitvale Avenue, Saratoga, CA 95070. In Compliance with the Americans with Disabilities Act, if you need assistance to participate in this meeting, please contact the City Clerk at bavrit@saratoga.ca.us or calling 408.868.1216 as soon as possible before the meeting. The City will use its best efforts to provide reasonable accommodations to provide as much accessibility as possible while also maintaining public safety. [28 CFR 35.102-35.104 ADA title II] Saratoga Planning Commission Draft Minutes – Page 1 of 2 DRAFT MINUTES WEDNESDAY SEPTEMBER 14, 2022 SARATOGA PLANNING COMMISSION REGULAR MEETING Chair Zheng called the virtual Regular Meeting to order at 7:00 p.m. via teleconferencing through Zoom. Prior to Roll Call, the Chair and Community Development Director explained that the Planning Commission meeting was conducted pursuant to Government Code section 54953(e) of the Ralph M. Brown Act allowing teleconferencing during a proclaimed state of emergency when state or local officials have imposed or recommended measures to promote social distancing. The Planning Commission met all the applicable notice requirements and the public is welcome to participate in this meeting. Information on how the public can observe the meeting and provide public comment was also shared. Additionally, the Chair explained that votes would be taken through roll call. ROLL CALL PRESENT: Chair Herman Zheng, Vice Chair Clinton Brownley, Commissioners Jojo Choi, Anjali Kausar, Ping Li, Razi Mohiuddin ABSENT: Commissioner Sunil Ahuja ALSO PRESENT: Debbie Pedro, Community Development Director Victoria Banfield, Associate Planner Nicole Johnson, Senior Planner 1.APPROVAL OF MINUTES Action Minutes from the Regular Planning Commission Meeting of August 10, 2022. Recommended Action: Approve Minutes of Regular Planning Commission Meeting of August 10, 2022. KAUSAR/LI MOVED TO APPROVE THE MINUTES OF THE AUGUST 10, 2022 MEETING. MOTION PASSED. AYES: BROWNLEY, CHOI, KAUSAR, LI, ZHENG. NOES: NONE. ABSENT: AHUJA. ABSTAIN: MOHIUDDIN. ORAL COMMUNICATIONS ON NON-AGENDIZED ITEMS: NONE REPORT ON APPEAL RIGHTS 2.PUBLIC HEARING 2.1 Application PDR21-0032/ARB21-012020538 Lynde Court (503-52-012); Rajesh & Sunita Lalwani (Continued from September 14, 2022) – The applicant is Recommended Action: Adopt Resolution No. 22-020 approving the project subject to conditions of approval included in Attachment 1. KAUSAR/LI MOVED TO CONTINUE ITEM TO OCTOBER 12, 2022 PLANNING COMMISSION MEETING. MOTION PASSED. AYES: BROWNLEY, CHOI, KAUSAR, LI, MOHIUDDIN, ZHENG. NOES: NONE. ABSENT: AHUJA. ABSTAIN: NONE. 4 Saratoga Planning Commission Draft Minutes – Page 2 of 2 2.2 Application PDR21-0028/ARB20-0068; 14680 Sobey Road (397-04-037); Liberty Mor – The applicant is Recommended Action: Adopt Resolution No. 22-021 approving the project subject to conditions of approval included in Attachment 1. KAUSAR/LI MOVED TO ADOPT RESOLUTION NO. 22-021, SUBJECT TO CONDITIONS. MOTION PASSED. AYES: BROWNLEY, CHOI, KAUSAR, LI, MOHIUDDIN, ZHENG. NOES: NONE. ABSENT: AHUJA. ABSTAIN: NONE. 3. DIRECTOR ITEMS: NONE 4. COMMISSION ITEMS: NONE 5. ADJOURNMENT Commissioners Kausar/Zheng moved to adjourn the meeting at 9:10 PM. Minutes respectfully submitted: Frances Reed, Administrative Analyst City of Saratoga 5 REPORT TO THE PLANNING COMMISSION Meeting Date: October 12, 2022 (Continued from September 14, 2022) Application: PDR21-0032/ARB21-0120 Address/APN: 20538 Lynde Court/503-52-012 Property Owner: Rajesh & Sunita Lalwani From: Debbie Pedro, Community Development Director Report Prepared By: Victoria Banfield, Associate Planner 6 Report to the Planning Commission 20538 Lynde Court – Application # PDR21-0032/ARB21-0120 October 12, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a new 3,403 square foot two-story residence with a 752 square foot attached accessory dwelling unit. Three protected trees are proposed for removal. STAFF RECOMMENDATION Adopt Resolution No. 22-020 approving the project subject to conditions of approval included in Attachment 1. Pursuant to City Code Section 15-45.060(a)(1), approval by the Planning Commission is required as the project includes new multi-story main structure. PROJECT DATA Gross/Net Site Area: 11,066 sq. ft. (0.25 acres) Average Site Slope: Less than 10% General Plan Designation: Medium Density Residential (M-10) Zoning: R-1-10,000 (Single Family Residential) Proposed Allowed/Required Site Coverage Residence w/Garage ADU Driveway/Walkways Patios/Porches Total Proposed 1,972 sq. ft. 752 sq. ft 598 sq. ft. 1,383 sq. ft. 4,705 sq. ft. (42.5%) 7,439.6 sq. ft. (60%) Floor Area Residence w/Garage ADU Total Floor Area 3,403 sq. ft. 752 sq. ft. 4,155 sq. ft.* 4,340 sq. ft.* Height 25’11” 26’ Setbacks Front: Left Side: Right Side Rear: 1st Floor 2nd Floor 30’11” 33’8” 8’5” 21’7” 8’6” 13’3” 28’6” 35’ 1st Floor 2nd Floor 25’ 25’ 8’ 3” 13’ 3” 8’ 3” 13’ 3” 25’ 35’ Grading Cut = 60 CY Fill = 10 CY Export = 50 CY No grading limit in the R-1-10,000 zoning district * Includes one-time 800 sq.ft. allowance for ADU per City code Section 15-56.025(5)(b). Background The Planning Commission previously reviewed the project at their meeting of September 14, 2022. The Commission continued the item with the recommendation that the second story balcony on the front elevation be removed and the windows on the front elevation be reduced in height to reduce privacy impacts to the neighboring property across the street located at 20579 Lynde Court. 7 Report to the Planning Commission 20538 Lynde Court – Application # PDR21-0032/ARB21-0120 October 12, 2022 Page | 3 The applicant has revised the project plans which include the following modifications: • The second story balcony has been reduced in length by 6’-9” from 27’-1” to 20’-4.” The reduction of the balcony length has been accomplished by enclosing the right side of the balcony to create a closet for the master bedroom. The balcony depth remains the same at 4’-4.” • The second story sliding glass doors on the front elevation have been reduced in length by 6’-6 ½” from 23’ to 16’-5 ½.” The reduction in the length of the sliding glass doors has been accomplished by removing one of the glass doors to accommodate the closet on the right side of the balcony. The height of the sliding glass doors remains the same. SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The project site is located at 20538 Lynde Court in the R-1-10,000 (Single Family Residential) zoning district. The 11,066 square foot property has an average slope of 1.4% and is currently developed with a single-story residence. The site is surrounded by single-family homes to the north, south and west. Saratoga High School is located to the east of the site, across Saratoga- Sunnyvale Road. Project Description The proposed lower floor of the residence is 1,972 square feet and includes a living room, dining room, kitchen, office and attached two-car garage. The lower floor also contains an additional 752 square foot attached ADU which has one bedroom, one bathroom, living room, and kitchen. The proposed upper floor is 1,431 square foot and includes three bedrooms. The applicant has provided a color and materials board (Attachment 5). Below is a list of the proposed exterior materials. Detail Colors/Materials Exterior White Stucco and Brown Wood Siding Windows/Trim Black Metal Window Frames Front door/Garage door Brown Wood Roof White (flat roof) Trees The project Arborist inventoried eight (8) protected trees on the site. Three (3) protected tree are proposed for removal. The City Arborist has approved the removal of one Liquidambar, one Silver Maple, and one Modesto Ash which are in poor condition due to disease and decay. Replacement trees are required to be planted on the site (Attachment 2). Landscaping The installation of front yard landscaping is required prior to building permit final inspection. The project includes a condition of approval that landscaping is to be installed per City Code Section 15- 12.095. 8 Report to the Planning Commission 20538 Lynde Court – Application # PDR21-0032/ARB21-0120 October 12, 2022 Page | 4 FINDINGS Design Review The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be limited to the location of the new residence, as well as contouring the site as necessary to direct water to landscaped areas. The site development is appropriate to the site’s natural constraints with single family homes around it. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that three protected trees are requested for removal which are in poor condition. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the second story has a proposed height that does not exceed the maximum allowable height for a single-family residence and proposed setbacks that are in compliance the minimum required by the zoning district. The second story windows on the side elevations will have bottom sill heights of 6’-6” and both balconies will have 6’ tall privacy walls on the sides of the balcony to avoid impacts to the privacy of adjoining properties. A row of 24” box evergreen trees will also be planted along the northern side property line to help mitigate privacy impacts. No community viewsheds are located in the vicinity of the project. d. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the building has varying exterior materials and architectural forms. The brown wood siding combined with the white smooth stucco help break up the appearance of mass. The varying roof forms and recessed second story also reduce the overall mass of the structure. 9 Report to the Planning Commission 20538 Lynde Court – Application # PDR21-0032/ARB21-0120 October 12, 2022 Page | 5 e. The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood and streetscape. This finding may be made in the affirmative in that the project includes a condition of approval that front yard landscaping is to be installed prior to building department final inspection. The City Code requires that at least 50% of the front setback area be landscaped. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the project complies with required setbacks. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk and avoiding unreasonable interference with privacy and views as detailed in the findings above. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable as the project is not on a hillside lot. The project is not located on a ridgeline, and will not affect any significant hillside features or community viewsheds. Neighbor Notification and Correspondence The Community Development Department mailed public notices to property owners within 500 feet of the site. The public hearing notice and description of the project was also published in the Saratoga News. The City received five (5) completed neighbor notification forms, two of which had no comments. Three neighbor notification forms contained comments which expressed concerns with the architectural style of the home being out of place in the neighborhood, potential privacy impacts from the second story windows and balconies, and potential impacts to sunlight. The City also received two (2) letters of support from two (2) neighbors residing on Lynde Court and seven (7) comment letters from four (4) neighbors further detailing concerns with shadows and potential privacy impacts from the second story windows and balconies. The letters include photos of the neighborhood and story poles, as well as additional diagrams (Attachment 3). The proposed second story windows on the side elevations will have sill heights 6’-6” and the balconies will have 10 Report to the Planning Commission 20538 Lynde Court – Application # PDR21-0032/ARB21-0120 October 12, 2022 Page | 6 6’ tall privacy walls on the sides to avoid impacts to the privacy of adjoining properties. A row of 10’ tall evergreen trees will also be planted along the northern side property line for privacy. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single-family residence and small structures in a residential area. The project, as proposed, is for the construction of a new residence replacing an existing residence. ATTACHMENTS 1. Resolution No. 22-020 2. Arborist Report 3. Neighbor Notification Forms 4. Story Pole Certification 5. Material Board 6. Revised Project Plans 11 RESOLUTION NO: 22-020 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0032 AND ARBORIST REVIEW ARB21-0120 20538 LYNDE COURT (APN 503-52-012) WHEREAS, on December 8, 2021 an application was submitted by Rajesh & Sunita Lalwani requesting Design Review approval for a 3,369 square foot two-story residence with a 752 square foot attached accessory dwelling unit. Three protected trees are proposed for removal. The site is zoned R-1-10,000 with a General Plan Designation of Medium Density Residential (M-10). WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA) and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on October 12, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed manner. 12 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 2 Section 5: The City of Saratoga Planning Commission hereby approves PDR21-0032 and ARB21-0120 for 20538 Lynde Court (APN 503-52-012), subject to the Findings and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 12th day of October 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ________________________________________ Herman Zheng Chair, Planning Commission 13 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0032 / ARB21-0120 20538 LYNDE COURT (APN 503-52-012) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. 14 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 4 COMMUNITY DEVELOPMENT DEPARTMENT 5. The development shall be located and constructed to include those features, and only those features, as shown on the Approved Development Plans. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 6. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut-off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 7. In order to comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 8. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 9. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 10. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. 15 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 5 c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency, and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall consider potential damage to roots of protected trees 11. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 12. Privacy screening shall be planted along the northern side property lines as depicted in the approved Landscape Plans. The screening trees will be of an evergreen species, such as Swan Hill Olive or Carolina Cherry Laurel trees, or similar, with a yearly growth rate of approximately 2 - 3 feet per year and shall be at least 10 feet in height at the time of planting. 13. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 14. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. FIRE DEPARTMENT 15. The owner/applicant shall comply with all Fire Department requirements. ARBORIST 16. All requirements in the City Arborist Approval Letter dated June 1, 2022 are hereby adopted as conditions of approval and shall be implemented as part of the approved plans. PUBLIC WORKS/ENGINEERING 17. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 18. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any 16 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 6 City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 19. Applicant / Owner shall make the following improvements in the City right-of-way: a. Remove existing driveway approach and replace with new driveway approach per City Standard Detail 205 & 206. See City of Saratoga Standard Details for removal and new installation. New flow line shall conform to existing flow lines and grade. 20. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 21. All new/upgraded utilities shall be installed underground. 22. Applicant / Owner shall maintain the streets, sidewalks and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 23. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g. landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay-Friendly Landscaping). 24. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing storm water pollution: a. Owner shall implement construction site inspection and control to prevent construction site discharges of pollutants into the storm drains per approved Erosion Control Plan. b. The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non-storm water management through all phases of construction (including, but not limited to, site grading, building, and finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. c. City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 25. Prior to the commencement of any earthwork/grading activities, the permittee shall arrange a pre-construction meeting. The meeting shall include the City of Saratoga Grading Inspector (408-868-1201), the grading contractor, and the project Soils Engineer. The permittee or representative shall arrange the pre-construction meeting at least 48 hours prior to the start of any earthwork activities. 17 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 7 26. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. 27. Prior to the Building final, all Public Works conditions shall be completed per approved plans. 28. Upon the completion of this project the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the City's building inspector to be properly elevated. Such certification and verification shall be provided to the City’s Floodplain Administrator. 18 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 8 DESIGN REVIEW FINDINGS PDR21-0032 / ARB21-0120 20538 LYNDE COURT (APN 503-52-012) The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be limited to the location of the new residence, as well as contouring the site as necessary to direct water to landscaped areas. The site development is appropriate to the site’s natural constraints with single family homes around it. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that three protected trees are requested for removal which are in poor condition. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the second story has a proposed height that does not exceed the maximum allowable height for a single-family residence and proposed setbacks that are in compliance the minimum required by the zoning district. The second story windows on the side elevations will have bottom sill heights of 6’-6” and both balconies will have 6’ tall privacy walls on the sides of the balcony to avoid impacts to the privacy of adjoining properties. A row of 24” box evergreen trees will also be planted along the northern side property line to help mitigate privacy impacts. No community viewsheds are located in the vicinity of the project. d. The overall mass and the height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the building has varying exterior materials and architectural forms. The brown wood siding combined with the white smooth stucco help break up the appearance of mass. The varying roof forms and recessed second story also reduce the overall mass of the structure. 19 20538 Lynde Court Application # PDR21-0032 / ARB21-0120 October 12, 2022 Resolution #22-020 Page | 9 e. The landscape design minimizes hardscape in the front setback area and contains elements that are complimentary to the neighborhood and streetscape. This finding may be made in the affirmative in that the project includes a condition of approval that front yard landscaping is to be installed prior to building department final inspection. The City Code requires that at least 50% of the front setback area be landscaped. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the project complies with required setbacks. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding may be made in the affirmative in that the proposed project conforms to the applicable design policies and techniques in the Residential Design Handbook in terms of compatible bulk and avoiding unreasonable interference with privacy and views as detailed in the findings above. h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. This finding is not applicable as the project is not on a hillside lot. The project is not located on a ridgeline, and will not affect any significant hillside features or community viewsheds. 20 Community Development Department 13777 Fruitvale Avenue Saratoga, CA 95070 www.saratoga.ca.us/171/trees 408.868.1276 CITY OF SARATOGA ARBORIST APPROVAL Conditions of Approval and Tree Protection Plan Prepared by Christina Fusco, City Arborist Application No. ARB21-0120 Phone: (408) 868-1276 Address: 20538 Lynde Ct Email: cfusco@saratoga.ca.us Owner: Rajesh Lalwani & Sunita Lalwani APN: 503-52-012 Date: June 1, 2022 PROJECT SCOPE: The applicant has submitted plans to demolish the existing residence and build a new two-story residence. Three trees are requested for removal to construct the project. PROJECT DATA IN BRIEF: Tree security deposit – Required - $4,750 Tree protection – Required – See Conditions of Approval and attached map. Tree removals – Trees 7, 11, and 13 are approved for removal once building permits have been issued. Replacement trees – Required = $2,840 ATTACHMENTS: 1 – Findings and Tree Information 2 – Tree Removal Criteria 3 – Conditions of Approval 4 – Map Showing Tree Protection 1 of 9 21 205387 Lynde Court Attachment 1 FINDINGS: Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. One tree is in conflict with the new house, and two trees re dying. These trees meet the City’s criteria allowing them to be removed and replaced as part of the project, once building division permits have been obtained. Attachment 2 contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No. Species Criteria met Comments 7 Liquidambar styraciflua 1, 2, 6, 9 Decay present 12 Silver maple Acer saccharinum 1, 6 Dying from ganoderma 13 Modesto Ash Fraxinus velutina ‘Modesto’ 1, 6 Dying New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15- 50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1)The tree information and recommendations from the submitted arborist report dated March 15, 2022; 2)The Project Data in Brief, the Conditions of Approval, and map showing tree protection from this report dated June 1, 2022. TREE INFORMATION: Project Arborist: David Beckham Date of Report: March 15, 2022 Number of protected trees inventoried: 8 Number of protected trees requested for removal: 3 A table summarizing information about each tree is below. 2 of 9 22 205387 Lynde Court Attachment 1 Table 2: Tree information from submitted arborist report dated March 15, 2022. 3 of 9 23 205387 Lynde Court Attachment 1 4 of 9 24 20538 Lynde Court Attachment 2 TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1)The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2)The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. (3)The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. (4)The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. (5)The age and number of healthy trees the property is able to support according to good forestry practices. (6)Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7)Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8)Any other information relevant to the public health, safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9)The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. (10)The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. (11)The necessity to remove a tree following the creation of defensible space within 100 feet of a structure located within the Wildland Urban Interface, in accordance with defensible space standards established by CAL FIRE or as determined by Santa Clara County Fire Department, and that risk of increased wildfire cannot reasonably be addressed through maintenance or without tree removal. 5 of 9 25 20538 Lynde Court Attachment 3 CONDITIONS OF APPROVAL 1.Owner, Architect, Contractor: It is the responsibility of the owner, architect, and contractor to be familiar with the information in this report and implement the required conditions. 2.Permit: a.Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. b.No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 3.Final Plan Sets: a.The tree information and recommendations from the submitted arborist report dated March 15, 2022; b.The Project Data in Brief, the Conditions of Approval, and map showing tree protection from this report dated June 1, 2022. 4.Tree Protection Security Deposit: a.Is required per City Ordinance 15-50.080. b.Shall be $4,750 for tree(s) 1, 10, 11, 14, 15. c.Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d.May be in the form of cash, check, or a bond. e.Shall remain in place for the duration of construction of the project. f.May be released once the project has been completed, inspected, and approved by the City Arborist. 5.Tree Protection Fencing: a.Shall be installed as shown on the attached map. b.Shall be shown on the Site Plan. c.Shall be established prior to the arrival of construction equipment or materials on site. d.Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. e.Shall be posted with signs saying, “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, CHRISTINA FUSCO (408) 868- 1276”. f.Call City Arborist, Christina Fusco at (408) 868-1276 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. g.Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 6 of 9 26 20538 Lynde Court Attachment 3 6.Construction: All construction activities shall be conducted outside tree protection fencing unless permitted as conditioned below. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching for utility installation, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 7.Work inside fenced areas: a.Requires a field meeting and approval from City Arborist before performing work. b.Requires Project Arborist on site to monitor work. 8.Project Arborist: a.Shall be David Beckham unless otherwise approved by the City Arborist. b.Shall visit the site every two weeks during grading, trenching, or digging activities and every six weeks thereafter. A letter/email shall be provided to the City after each inspection which documents the work performed around trees, includes photos of the work in progress, and provides information on tree condition during construction. c.Shall supervise any permitted pruning or root pruning of trees on site. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. 9.Tree removal: Trees 7, 12, and 13 meet the criteria for removal and may be removed building division permits have been obtained. 10.New trees: a.New trees equal to $2,840 shall be planted as part of the project before final inspection and occupancy of the new home. New trees may be of any species and planted anywhere on the property as long as they do not encroach on retained trees. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b.Trees shall be replaced on or off site according to good forestry practices and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance, and other significant beneficial characteristics of the removed trees. 11.Damage to protected trees that will be retained: a.Should any protected tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessary number of new trees, some of the value for trees may be paid into the City’s Tree Fund. b.Water loving plants and lawns are not permitted under oak tree canopies. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 7 of 9 27 20538 Lynde Court Attachment 3 12.Final inspection: At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the city, call City Arborist for a final inspection. Before scheduling a final inspection from the City Arborist, have the project arborist do an inspection, prepare a letter with their findings, and provide that letter to the city for the project file. 8 of 9 28 AƩachment 4 20538 Lynde Court 9 of 929 30 31 From:Jerry Han To:V c oria Banf eld Cc:Li Penny Subject:Re: Privacy Concerns of 20538 Lynde Court Project Date:Wednesday September 14 2022 11:23:27 AM Attachments:image004 ng image.png image.png image.png image.png image.png Hi Victoria, Thank you and other mission members' visit yesterday. Here I just want to add one more thing about the rear side balcony since some members thought there is a wall extended outside. For the yellow frame portion, actually there is no wall there but it's miss leading with the tall poles there. The contractor finally admitted that they can see a lot of our backyard although they made a mistake in the beginning as a professional contractor. Please find the following email exchange. They claimed to plant the 20-30 feet trees to address my privacy concern caused by their backyard balcony, but it comes with the cost of losing my backyard sunshine. Based on measurements, it will block over 2000 sq ft of sunshine in the morning. That explains why they don't plan to plant trees near the border of the other neighborhood since those trees on the east will block 20538's front balcony sunshine, for their own benefits. I don't think this shows respect to the neighbourhood. Not to mention in the beginning they put the side windows which face our two bathrooms at a height of 4 feet and 6 inches high, which totally does not respect the neighbourhood. Could you please update these latest information to the members before the hearing if possible? Sorry for bothering you many times, but this project concerns us a lot. Thank you very much for your help! Appreciate it! 32 33 34 From:Joyce To:Victoria Banfield Subject:Re: Planning Commission September 2022 Meetings Date:Friday, September 9, 2022 5:41:39 PM Attachments:09132022 Site Visit Agenda.pdf 09142022 Meeting Agenda web.pdf Thank you so much for the information. Unfortunately, I am 11 hour time difference away from home, won’t to be able to attend the meeting. However, I expressed my concern to the homeowner, wished him good luck at the same time about two weeks ago. Didn’t hear from from them. 1.The proposed two story home would lower the value of my home. Because I, so are the potential buyers I would assume, love the fact that mine is the only two story home in the cul de sac, thus the privacy and the bragging right are worth some. 2. At the moment, I can enjoy a nice tree top and roof top view from my study window , the proposed modernistic two story home would impose me a light sharp edged block arising out of from the suburban residential sight. I am imagining an eye sore looking out. Since rhe homeowber didn’t respond to my message, thought to write to you directly. I don’t mind you forwarding this email to them. They are great neighbors and I wish them the best. I just hope that I don’t became the collateral damage during the process. Thank you Victoria ! Joyce Sent from my iPhone 35 City of Saratoga Neighbor Notification Form RECEIVED ;fl,, Project Address: 20538 Lynde Ct, Saratoga, CA 95070 CITY OF SARATOGA A project is proposed at the above address. The City asks that you sign this form to indicate you have had an opportunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to viewthe plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-868-1222 if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name: H�h 7 'p Ly cl'?\ Neighbor Address: _i O f: / f j 'j � ri£. (0t lJ Date: Ct fl It? D) )_ 7 n .9 D ? Neighbor Contact Info: (phone or email): ____..l,,..-<../-__ G------,,·_,�--0--+{--�-----,/-1--\) _______ _ -This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 A �Jr 1Y' lsl/LAj I h bvvr &-ffl 1J1Ufn �I i My signature be1,bw certifies that I am aware of the prol(psal. NEIGHBOR SIGNATURE:--�-+------===-��---------------====----- Revised February 2014 36 City of 5aratoga Neighbor Notification Form Project Address: 20538 Lynde Ct, Saratoga, CA 95070 RECEIVED fr ., f ? ')1 �(;;J,-.�M™5A A project is proposed at the above address. The City asks that you sign this form to indicate you have had an opportunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment .. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant shoul d allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-868-1222 lfyou have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name: ___ ___.....8'-'.�--'-�-"--"--�--------Date: / .J/ S /],Al),/ Neighbor Address: --"'2-Jb�-_Y>_..__=-i-j--1---'Js-:c_ ... '-----"C,t-"'---'--';'--=-'5��----..'-----""c.Jt-'---> -1f--=-)0----+-Q-� __ _ Neighbor Contact InfO: (phone or email): - This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 oJ!aJRJ, My signature below certifies Revised February 2014 37 38 39 .. --, . City of Saratoga Neighbor Notification Form Project Address: 20538 Lynde Ct, Saratoga, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an opportunity to review and comment on the proposal. Your signature is not an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-868-1222 if you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name: l<'J,-1 � Chtl:, CH I /\}Y'\Date: ]ecuh:t b,;;) 1l 2( Neighbor Address: d,0'5l}Q L1,fldK Ct. 5dCAo1---? CA 9S:d7o Neighbor Contact Info: (phone or email): Cb:is kCV\1�@) JW\.CA \ I " Co W\ -This enables the City to contact you if they have any questions Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 �far 1/ I Ri/4 -Rt utYckO:e, kt � kw� �4, $1\'.u �<'.'.if, \ill.. � ,;er\ ui« UJ\,\Cf!'� s k = Ii 1.U t/[ 1 '/\'J,;L all'I:: yti Ya ct a,,..A_ M 14.u:1 ea,L rurf&4 �P1(!Jul \¥. '"\)luw,_ MR.c ,J(lld.J_ Ll/):\{t:fu S.�> ,rr WtJJYe.__ <\6tl\�S. My signature below certifies that I am aware of the proposal. NEIGHBOR SIGNATURE: k�§. � c� 17 Revised February 2014 40 . -� City of Saratoga Neighbor Notification Form Project Address: 20538 Lynde Ct. Saratoga, CA 95070 After viewing the architecture plans of this project, we ha ve serious concerns because it will invade o ur privacy and greatly impact our current personal life. Please see the following concerns and questions. Concern #1: To avoid in vading neighbors' privacy, almost all existing 2-story houses in the near neighborhood (13869, 13877, 13885, 13893, 13901, & 13909 Lynde Ave. and 20553, & 20557 Dea rpark Ct.) have front an d back windows only on the 2nd floor. They DO NOT ha ve side windows on the 2 nd floor. Howe ver, this project proposed n ot only front and back windows but also left and right side windows on the 2n d floor. Activities in our backyard will be clearly visible through three right side windows on the 2nd floor of this proposed h ouse. Concern #2: These existing 2-story houses DO NOT have a balcony on the second floor. However, the project proposed two balconies on the 2nd floor: one in the front and the other in the back. Activities in our backyard are all exposed to people standing on these two balconies. Because of the geographical location and setback, peopl e standing in the front balcony of this proposed house can clearly see part of our backya rd. Concern #3: On ce again to minimize neighbors' privacy, front and back windows of these existing 2- story houses are �3 feet in height, some are �4 or 5 feet. However, both front and back windows/sliding doors of this project are �8 feet in height. Activities in our backyard are easily visible by the people inside the 2nd floor of this proposed ho u se through these big open windows/sliding doors. Concern #4: The design style of this proposed project is totally different from all existing ranch style houses in this neighbor. It will break the harmony of structure appearance of this area . Question: Based on the zoning compliance, the allowed/required right side setback of the main house (l51 floor) is 8' 3". However, this project proposed a 5' 4" right side setback. The main house (l 51 Floor) rear setback (proposed 24' 6" vs. allowed/required 26' 8") also has the similar incompliance. Will the city of Saratoga Planning Department approve this kind of proposal? If yes, what is the rational explanation of this decision? Neighbor Address: 20540 Lynde Ct. Saratoga, CA 95070 Neighbor Name: Koh-Shyan Chris Chiang Neighbor Signat u re: ��¢<=? � Date: December 6, 2021 C'_d' 7 Neighbor Name: -=Li-'--'n=g--=,� =u -=L��'--'-ne=--=C-'--'h=ia'-'-"i '-0,-. _________ Date: December 6, 2021 Neighbor Signature: � l6J4c--R L� 41 City of Saratoga Neighbor Notification Form Project Address: 20538 Lynde Ct, Saratoga, CA 95070 A project is proposed at the above address. The City asks that you sign this form to indicate you have had an opportunity to review and comment on the proposal. Your signature is nQt an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to viewthe plans but is not required to give you a physical copy. Once the application Is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please contact the City at 408-868-1222 If you have any questions. This notice is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. NeighborName: l.�·�,JR� �� SeJ�A Neighbor Address: 2.05S: k-�£7\R (t • Neighbor Contact Info: (phone or email): -This enables the City to contact you if they have any questions Date: \2-{ 06/ 2-I ' Please address any initial concerns below (attach additional sheets if necessary): Feel free to mail this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 My signature below certifi�� �m aware of the proposal. NEIGHBOR SIGNAlURE: cu� Revised February 2014 42 City of Saratoga Neighbor Notfflc:ation Form A project Is proposed at the above address. The City asks that you sign this form to Indicate you have had an opportunity to review and comment on the proposal. Your signature Is nm; an acceptance of the plans, only an acknowledgement that you have had an opportunity to comment. IMPORTANT NOTE FROM CITY: These plans are PRELIMINARY ONLY and may change as the project moves forward. Architectural Plans are protected under copyright law. The applicant should allow you to view the plans but is not required to give you a physical copy. Once the application is submitted, you may review a full sized set of plans at City Hall during normal business hours. The applicant should inform you when the plans will be submitted. Please cont.act the Oty at 408-868-1222 If you have any questions. This notice Is being provided to all of the adjoining property owners and the property owner(s) across the street from the project address. The City will send an additional notice to adjacent neighbors prior to a decision being made on the project. Neighbor Name: [\e 'a_(l le, Q 0l\ fu (\ 0 v DN2..k.:\Q Date: Neighbor Address: 8' OSti> '-\ LI oc\ e. Ck . ) 8Jr0Ju13 °'­CA ttBllo Neighbor Contact Info: (phone or email): _-4..;..:0"-'0'-·-�-1....;..;;...d-_-...::::Oi];..;;,,._-'-'Q._"--'---------- -This enables the City to contact you If they have any questions Please address any lnltlal concerns below (attach addltlonal sheets If necessary): Feel free to mall this form directly to the City: City of Saratoga Planning Department; 13777 Fruitvale Avenue; Saratoga CA 95070 My signature below certifies that I am aware of the proposal. NEIGHB0RSIG�1 � Revised February 2014 43 From:Jerry Han To:Victoria Banfield; Li Penny Subject:Privacy Concerns of 20538 Lynde Court Project Date:Monday, August 15, 2022 1:42:48 PM Attachments:Backyard Privacy Concern - 20538 Lynde Ct.pdf Hi Victoria, I reviewed the updated project design of 20538 Lynde Court. house with you on Aug 12, 2022. As my privacy concern of this project was not fully addressed in the updated design, here I would like to reiterate it again. We have strong concerns about the planned balcony and the French windows in the back of the project. First, there is no single house in this area which has a balcony in the front or back side. Secondly and most importantly, the balcony is 24.6 feet wide with two 8 feet French window sliding doors facing to the backyard. When standing on the right corner of the balcony, the neighbor can either intentionally or unintentionally see almost half of our backyard, around 3100 sq ft. It feels like we are on exhibit at the zoo and hurts our privacy a lot. Please find the attached drawing estimation based on project plan’s page 2. Even if there is no balcony, near the French windows the neighbor can see around 1500 sq ft of our backyard, which also hurts our privacy. I would appreciate your assistance to pass this information to the commission. I will also stop by City Hall this week to give you a copy of this letter with my and my wife's signatures. Thank you! Best regards,Jerry Han 44 121.80 0 45 August 12, 2022 Saratoga Planning Commission Attn.: Victoria Banfield 13777 Fruitvale Ave. Saratoga, CA 95070 Subject: Project Application of 20538 Lynde Court, Dear Chair Zheng, Vice Chair Brwonley, and Planning Commission members, Our names are Koh-Shyan Chris Chiang and Ling-Ju Lynne Chiang. We are the owners of our house at 20540 Lynde Court and have been living here peacefully and happily since 1988. Last December we were informed by the applicant of 20538 Lynde Court project. Consequently, we sent our privacy concerns regarding this proposed project to the Planning Commission by the way of the City of Saratoga Neighbor Notification Form on December 6, 2021. As I stated in the form, the majority (more than 90%) of two-story houses in our Reid/Lynde/Deerpark neighborhood have no balconies and no side windows. In addition, most of the front and back windows of these houses have a maximum height of 3 feet. Please see the attached “Reid/Lynde/DeerPark 2-Story Houses Summary” document for more details. In contrast, the new 20538 Lynde Court proposed house design has side windows, front and back balconies, and 7 feet tall sliding doors. A south side window facing our backyard, the front and the back balconies, and 7 feet tall sliding doors in the front and back will definitely be major privacy issues for us. Because majority of our backyard will be visible from the above mentioned locations. Since we are retired seniors spending most of our time in our yard, with this new design we will be living under the constant pressure of worrying that our neighbors will be looking into our backyard either intentionally or unintentionally. A recent review of this project plan at City Hall on July 20, 2022 showed that the project applicants simply ignored our privacy concerns and moved forward with their original design without any communication with us. Therefore, we would like to bring our unaddressed privacy issues regarding 20538 Lynde Court project to your attention. 46 We respect that our neighbors have the right to pursue and build their new dream house. However, if this project comes at the cost of our anxiety and impacts our existing daily activities in our home and backyard, someone’s new dream house then becomes a nightmare for us living in our existing house. Furthermore we are conscious about not disrupting the peace and harmony of this neighborhood. We worry that this will be broken if the project proceeds. In our country, established with rules and laws, all citizens have the right to build, defense and preserve their dream homes, either new ones or existing ones, with all their heart, all their soul, all their mind, and all their strength. So I am requesting your assistance to resolve these unaddressed privacy issues. Sincerely, Koh-Shyan Chris Chiang & Ling-Ju Lynne Chiang Enclosures: As stated 47 2-Story Houses in Reid/Lynde/Deerpark Neighborhood 48 20538 12 3 4 5 6 7 8 9 10 11 20540 49 # Address Balcony Side Window Front Window Back Window 1 20575 Reid Lane No No 3’ tall windows Unknown 2 20587 Reid Lane No No 3’ tall windows Unknown 3 13909 LyndeAve. No No 3’ tall windows 3’ tall windows 4 13901 LyndeAve. No No 3’ tall windows 3’ tall windows 5 13893 LyndeAve. No No 3’ tall windows 3’ tall windows 6 13885 LyndeAve. No No 3’ tall windows 4’ tall windows 7 13877 LyndeAve. No No 3’ tall windows 3’ & 3.5’ tall windows 8 13869 LyndeAve. No One 3’ tall octagon window 3’ tall windows 3’ tall windows 9 20557 Deerpark Ct. No No 3’ tall windows Unknown 10 20531 Deerpark Ct. No No 3’ tall windows Unknown 11 20576 Lynde Ct. No 2’ & 4’ tall windows One 4’ tall window Unkown 50 House #1 20575 Reid Lane 51 House #2 20587 Reid Lane 52 House #3 13909 LyndeAve. 53 House #4 13901 LyndeAve. 54 House #5 13893 LyndeAve. 55 House #6 13885 LyndeAve. 56 House #7 13877 LyndeAve. 57 House #8 13869 LyndeAve. 58 House #9 20557 Deerpark Ct. 59 House #10 20531 Deerpark Ct. 60 House #11 20576 Lynde Ct. 61 August 15, 2022 Saratoga Planning Commission Attn.: Victoria Banfield 13777 Fruitvale Ave. Saratoga, CA 95070 Subject: Project Application of 20538 Lynde Court, Dear Chair Zheng, Vice Chair Brownley, and Planning Commission members, To give you a better understanding of how this proposed project will seriously impact our daily life because of privacy concerns, Ms. Banfield suggested sending you pictures of our backyard facing this project. Attached are 3 sets of pictures taken after the applicant installed “story poles” on the site. 1.The first set of pictures shows what we can see from the ground level of our backyard to the front balcony of this project. 2.The second set of pictures shows the south side windows on the 2 nd floor of this project. These pictures were taken at various locations in our backyard, one of them was about 100 feet away from the fence. 3.The third set of pictures shows the back balcony. In addition, we are sending you the fourth set of pictures taken at the top of a fence separating our backyard and the applicant’s property. We raised a question about side setback compliance in last December. Based on the zoning compliance, the allowed/required right side setback of the main house (1st floor) is 8’ 3”. However, this project proposed a 5’ 4” right side setback. During my last visit to City Hall on July 20, 2022, Ms. Banfield told me the applicant has corrected his design to meet the compliance. The pictures shows that the current right side setback of the main house (1 st floor) is still 5’ 4”. There is one more issue regarding the applicant’s plan to mitigate our privacy concerns. This plan will actually create more problems for us than solving our privacy concerns. First, various tree species will take 10 – 20 years to reach enough height to block my neighbor’s view to our backyard. Second, there are grapevines in our backyard near the 62 fence. These new tree canopies will block sunshine and hinder growth of our existing grapevines. Third, since these trees will be planted so close to our backyard, we will be then forced to clean up falling leaves and trim branches regularly. Thank you for taking our privacy concerns and right side setback compliance issue into your consideration of this project development. We really hope that this project can reach a mutually acceptable solution for the applicants and all neighbors, so that the peace and harmony of our neighborhood will be preserved and grow stronger. Sincerely, Koh-Shyan Chris Chiang & Ling-Ju Lynne Chiang Enclosures: As stated 63 Privacy Concerns and Side Setback Issue of 20538 Lynde Ct. 64 Picture #1-1 Front Balcony 65 Picture #1-2 Front Balcony 66 Picture #1-3 Front Balcony 67 Picture #2-1 Right Side Windows 68 Picture #2-2 Right Side Windows 69 Picture #2-3 Right Side Windows 70 Picture #2-4 Right Side Windows 71 Picture #3-1 Back Balcony 72 Picture #3-2 Back Balcony 73 Picture #4-1 Right Side Setback 74 Picture #4-2 Right Side Setback 75 Picture #4-3 Right Side Setback 76 September 7, 2022 Saratoga Planning Commission Attn.: Victoria Banfield 13777 Fruitvale Ave. Saratoga, CA 95070 Subject: Project Application of 20538 Lynde Court, Dear Chair Zheng, Vice Chair Brownley, and Planning Commission members, Our names are Bi Jerry Han and Yanping Penny Li . We are the owners of our house at 20526 Lynde Court and just moved to this neighborhood in June last year. Last December we were informed by the applicant of the 20538 Lynde Court project. Consequently, we sent our privacy concerns regarding this proposed project to the Planning Commission in December 2021 and Aug 2022. As we stated, the balcony is 24.6 feet wide with two 8 feet French window sliding doors facing to the backyard. When standing on the boundary of the balcony, the neighbor can either intentionally or unintentionally see almost half of our backyard. It feels like we are on exhibit at the zoo and hurts our privacy a lot. Please find the estimation and the vision from our backyard side (with the mutual vision the neighbor can see our backyard as well) based on the balcony pillar location. Please see the attached document page 1&2 for more details. The new 20538 Lynde Court proposed house design with 10 ft box trees. Based on the measurement from our backyard, 10 ft trees won’t solve the privacy issue. If the trees are too tall, that will block the morning sunshine from the east to our backyard, hurt our trees and vegetables, and prevent drying clothes. Basically, trying to plant the tree on our east side to prevent the privacy issue caused by the balcony & 8 feet French window sliding doors is creating a new problem when trying to solve the old problem. Please see the attached document page 3 for more details. We noticed that the shadow analysis was done for Dec, but the sun locations are different in June and Dec and only having data for Dec is not convincing. So, we hope this issue can be addressed as well. Please see the attached document page 4 for more details. During the recent open house, we noticed that the pillar which is set by the builder to specify the boundary of the house is 8 feet close to the existing fence. According to the recent boundary survey, our front yard boundary will be moved to our side a little while most of our backyard boundary will be moved to 20538 Lynde Court side a little, which gets the setback between the pillar and the new boundary smaller than 8 feet. This issue should be addressed. Please see the attached document page 5 for more details. 77 We also noticed that the 2nd floor bathroom’s window will face our two bathrooms’ windows directly, which concerns us a lot since this is extremely private. Please see the attached document page 6 for more details. Saratoga is a community where the common good prevails and neighborhoods are peaceful. We respect our neighbors’ right to build their new houses. However, the projects should not be built at the expense of our anxiety and privacy. Furthermore, we have concerns that it might disrupt the peace and harmony of this neighborhood. So, we are requesting your assistance to resolve these privacy issues and concerns. Sincerely, Bi Jerry Han & Yanping Penny Li Enclosures: As attached 78 Possible Vision View from Balcony Toward 20526 with DASH line. The solid line provided by builder wa s based on the condition that people stand in the room, not on the balcony. Plus, this is based on the balcony location provided by builder’s graph. Not based on real design. No extended wall to block view and protect our privacy. Vision triangles 79 My estimation for possible Vision View from Balcony Toward 20526. The view is based on the builder’s schematic drawing, and this ALIGNs with the real view based on the pillar location. See pictures. Real view from balcony toward 20526. This view is based on the balcony corner white pillar. 80 The proposed 10 feet tall tree won’t help on the privacy concern. See the following graph with 10 feet rod. This picture is taken near the fence. If the tree is too tall, that will hurt the morning sunshine to our backyard. Basically, planting the tree on our east side to prevent the privacy issue caused by the balcony & 8 feet French window sliding doors facing our backyard is creating a new problem when trying to solve th e old problem. Face the south Face the north 81 Sun locations are different in June and Dec. Only Dec data is not convincing. 82 Pillar distance to existing fence is only 8 feet. Not to mention the backyard fence(boundary) will be moved toward 20538 side further. 83 The 2nd story bathroom window faces our two bathrooms’ window directly. Proposed to use fixed opaque window for privacy concern. 84 85 EXTERIOR COLOR / MATERIAL SCHEDULE MATERIAL / APPLICATION CODE COLOR MANUFACTURE FLAT ROOF METAL WINDOW FRAMES WOODEN GARAGE DOOR SLIDING GLASS DOOR METAL GUARDRAIL M1 M3 M4 M5ROOFWALL MISC.* NOTES: EXACT COLORS TO BE VERIFIED WITH OWNER & ARCHITECT M8 M6 WHITE BLACK BLACK SMOOTH STUCCO WITH PAINT WHITE WOODEN SIDING M2 CONCRETE WALKWAY M7 C.H.I OR EQ JELWEN OR EQ. JELWEN OR EQ. GAF OR EQ. - - BLACK GREY - - WOODEN BROWN WOODEN BROWN ACCORDION GLASS DOOR M9 LA CANTINA OR EQ.BLACK NOTES: NOTES: • ALL DIMENSIONS ARE IN FEET AND INCHES. • DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED. • ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS--UNLESS OTHERWISE MENTIONED. • IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION. • THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION. • ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS. • THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.) REVISIONS : REV.DESCRIPTION DATE REVISED BY DATE: DRAWN BY: CHECKED BY: SHEET NO: SCALE: ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022 CONTACT : EMAIL :team@golivio.com PROJECT : THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA 650-209-6500 REVISED AS PER COMMENTS SAGAR126-APR-2022 REVISED AS PER COMMENTS SAGAR229-JUNE-2022 12" = 1'-0" A7.001 MATERIAL BOARD 20538, Lynde ct 29-JUNE-22 SAGAR SUBHENDU M1 M3 M4M2FLAT ROOF SMOOTH STUCCO WITH PAINT SLIDING GLASS DOORMETAL WINDOW FRAME WOODEN SIDING CONCRETE WALKWAYM5M6 M7 M8METAL GUARDRAIL WOODEN GARAGE DOOR M9ACCORDION GLASS DOOR 86 1. HERS VERIFICATION REQUIRED FOR THE HVAC COOLING, HVAC DISTRIBUTION SYSTEM FAN SYSTEMS, AND IAQ (INDOOR AIR QUALITY). PROVIDE EVIDENCE OF THIRD PARTY VERIFICATION (HERS) TO PROJECT BUILDING INSPECTOR, PRIOR TO FINAL INSPECTION. 2. AT FINAL INSPECTION, A MANUAL, COMPACT DISC, WEB-BASED REFERENCE, OR OTHER ACCEPTABLE MEDIA INCLUDING ITEMS 1 THROUGH 10 IN ACCORDANCE WITH CGBSC SECTION 4.410.1 SHALL BE PLACED IN THE BUILDING.3. ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINT CONTAINERS MUST REMAIN ON THE SITE FOR FIELD VERIFICATION BY THE BUILDING INSPECTOR.4. PRIOR TO ENCLOSING THE WALL AND FLOOR FRAMING, CONFIRMATION MUST BE PROVIDED TO THE BUILDING INSPECTOR SHOWING THE FRAMING MEMBERS DO NOT EXCEED 19% MOISTURE CONTENT.5. PRIOR TO OCCUPANCY OF THE BUILDING, PROVIDE A LETTER FROM THE CERTIFIED GREENPOINT RATER THAT VERIFIES COMPLIANCE WITH THE CHECKLIST AND THE MINIMUM REQUIRED POINTS WERE ACHIEVED. 6. PROPERTY LINE SURVEY WILL BE COMPLETED BY LICENSED SURVEYOR AND PROVIDED TO THE BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION7. BUILDING HEIGHT VERIFICATION WILL BE COMPLETED BY LICENSED SURVEYOR AND PROVIDED TO THE BUILDING INSPECTOR PRIOR TO FRAMING INSPECTION8. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE BUILDING INSPECTOR AT ROUGH INSPECTION9. EWAS SYSTEM WILL BE INSTALLEDNOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20221/4" = 1'-0"A1.001TITLE SHEET20538, Lynde ct22-SEPT-2022SAGARSUBHENDUNEW SINGLE FAMILY HOUSE20538 Lynde Ct, Saratoga, CA95070-5312ZONING COMPLIANCESQUARE FOOTAGE BREAKDOWNLOT CALCULATIONSVICINITY MAP N.T.SGENERAL NOTESCONTACT INFOSCOPE OF WORKSHEET INDEXDEFERRED SUBMITTALS ZONING COMPLIANCEEXISTINGPROPOSEDAllowed/RequiredLOT COVERAGEFLOOR AREASETBACKS (MAIN HOUSE)EXISTINGCHANGE INTOTAL PROPOSEDHABITABLE LIVING AREANON-HABITABLE AREANET LOT AREALANDSCAPE BREAKDOWN OVERALL:VICINITY MAP N.T.S2,494 SF3,953 (1,972 + 384+ 1,597) SF6639.6 SFFIRST LEVEL = 1,972 Sq.ft.COVERED PORCH = 384 Sq.ft.REMAINING IMPERVIOUS AREA =1,597 Sq.ft.3,403 (1,972 + 1,431) SF3,540 SFDEMOLITION OF 2,494 SF OF EXISTING RESIDENCE STRUCTURE, NEW CONSTRUCTION OF 3,403 SF MAIN HOUSE AND 752 SF ADU SINGLE FAMILY RESIDENCE OVER GROSS LOT AREA OF 11,066 SF.2,494SF(22.53 %)(35.7 %)(60 %)(22.53 %)(30.75 %)( 32 %)ADU=752 SF (6.80%)ADU=800 SF (7.22%)FIRST LEVEL= 1,972 Sq.ft, SECOND LEVEL= 1,431 Sq.ft44' 4" 78' 8" 9' 6" 8' 3" 30' 11" / 33' 8" 28' 6" / 35' 0"8' 5" / 21' 7" 8' 6" / 13' 3"FRONT (1st / 2nd)REAR (1st / 2nd)RIGHT SIDE (1st / 2nd)LEFT SIDE (1st / 2nd)464' 7" 25' 0" / 25' 0" 25' 0" / 35' 0" 8' 3" / 13' 3" 8' 3" / 13' 3" OWNER : RAJESH LALWANI & SUNITA LALWANI+1 (408) 621-9305 & +1 (408) 621-9342ARCHITECT: LIVIO BUILDING SYSTEMS CIVIL ENGINEER: RW ENGINEERING 408-262-1899LAND SURVEYOR: GREGLEWIS 831-359-0960 SITEFIRE SPRINKLERS IN ACCORDANCE WITH NFPA 13D AND STATE AND LOCAL REQUIREMENTS NOTE THAT PER CRC 313.3.7, A SIGN OR VALVE TAG SHALL BE INSTALLED AT THE MAIN SHUTOFF VALVE TO THE WATER DISTRIBUTION SYSTEM STATING THE FOLLOWING: WARNING, THE WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND PRESSURES TO FIGHT A FIRE. DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. DO NOT REMOVE THIS SIGN.LALWANI'S RESIDENCETHE PROJECT SHALL COMPLY WITH2019 CALIFORNIA BUILDING CODE (CBC)2019 CALIFORNIA RESIDENTIAL CODE2019 CALIFORNIA MECHANICAL CODE2019 CALIFORNIA PLUMBING CODE2019 CALIFORNIA ELECTRICAL CODE2019 CALIFORNIA ENERGY CODE2019 CALIFORNIA GREEN BUILDING STANDARDS CODECITY OF SARATOGA ORDINANCETYPE OF CONSTRUCTION : V-BZONE DISTRICT : R-1-10LOT AREA: 11,066 SFHISTORICAL: NONEW STRUCTURECALCULATION FOR ALLOWABLE FAR AS PER CITY CODE 15-12.0853,200 + 170(2) = 3,540 SFADU = 800SFNEW TWO STORY ALLOWABLE FAR 4340 Sq.ft. MAXTOTAL FLOOR AREA MAIN HOUSE LIVING AREA 3,403 SFADU LIVING AREA 748 SFTOTAL COUNTABLE AREA 4,151 SFGROSS LOT AREA = 11066 SFNET LOT AREA = GROSS LOTNET LOT AREA = 11,066IMPERVIOUS AREADRIVEWAY 505 SFWALKWAY 93 SFBACK SIDE PORCH 1100 SFFRONT PORCH 283 SFFIRST FLOOR 1972 SFADU 752 SFTOTAL 4705 SFAVERAGE SLOPE:S= 100(I)(L) or 0.0029(I)(L) 43560A AAVERAGE SLOPE = 0.00229(1)(160.7)/(11,067/43,560) = 1.4%FRONT YARD SETBACK CALCULATION:HARDSCAPE AREA 598 SFSOFTSCAPE AREA 997 SFFRONT YARD AREA 1595 SFSOFTSCAPE AREA (PERCENTGE) = 62.50 %SITEADU=752 SFADU=800 SFLOWEST ELEVATION POINT AT THE BUILDING EDGE FROM NATURAL GRADEHEIGHEST ELEVATION POINT AT THE BUILDING EDGE FROM NATURAL GRADEAVERAGE ELEVATION POINTTOP MOST ELEVATION POINT -MEASURED FROM AVERAGE POINT (ABOVE) TO THE TOP MOST POINT OF THE ROOF (INCLUDE SEPARATE CALCULATIONS FOR CHIMNEY, ETC.)HEIGHT CALCULATIONS464' 1" 465' 3" 25' 10.75" 26' 1,955SF3,724SF431SF3,724SF431SF502 SFTOTAL HARDSCAPE AREA (EXISTING AND PROPOSED): 4,705 Sq. ft.EXISTING SOFTSCAPE (UNDISTURBED): 0 Sq. ft.NEW SOFTSCAPE (NEW OR REPLACED LANDSCAPING)AREA: 6,361 Sq. ft.SUM OF ALL THREE SHOULD EQUAL THE SITE'S NET LOT AREA11,066 Sq.ft (Net Lot Area)LANDSCAPE BREAKDOWNFRONT YARD:DRIVEWAY 505 SFWALKWAY 93 SFTOTAL 598 SFFRONT SETBACK AREA = 1595 SFSITETOTAL IMPERVIOUS = 3953 + 752TOTAL IMPERVIOUS = 4,705 SFDRG NUMBER DARWING NAME DATEA1.001 TITLE SHEET 22-SEPT-22A1.002 NEIGHBOURHOOD SITE LAYOUT 22-SEPT-22A1.003 NEIGHBOURHOOD CONTEXT MAP 22-SEPT-22A1.004 SITE LAYOUT 22-SEPT-22A1.005 SITE DEMOLITION 22-SEPT-22A1.006 SHADOW ANALYSIS DIAGRAM 22-SEPT-22A1.007 PRIVACY DIAGRAM 22-SEPT-22A2.001 FIRST FLOOR PLAN 22-SEPT-22A2.002 SECOND FLOOR PLAN 22-SEPT-22A2.003 ROOF PLAN 22-SEPT-22A3.001 REAR AND LEFT ELEVATION 22-SEPT-22A3.002 FRONT AND RIGHT ELEVATION 22-SEPT-22A4.001 SECTION A-A & B-B 22-SEPT-22A5.001 DOOR SCHEDULE 22-SEPT-22A5.002 WINDOW SCHEDULE 22-SEPT-22A6.001 AREA CALCULATION 22-SEPT-22A7.001 MATERIAL BOARD 22-SEPT-22C-1 GRADING AND DRAINAGE PLAN 22-SEPT-22C-2 EROSION CONTROL PLAN 22-SEPT-22C-3 BEST CONSTRUCTION MANAGEMENT PRACTICE 22-SEPT-22L-1 LANDSCAPE PLAN 22-SEPT-22SU-1 TOPOGRAPHIC MAP 22-SEPT-22T-1 TREE PROTECTION INSTRUCTION 22-SEPT-22T-2 TREE PROTECTION INSTRUCTION 22-SEPT-22T-3 TREE PROTECTION PLAN 22-SEPT-22U-1 UTILITY PLAN 22-SEPT-22HARDSCAPE = 37.50%87 N 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'5' P.U.E.5' W .C. E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SI T E B E N C HM A RKM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.17464.50464.24464.46464.90464.20464.16464.22464.20464.31464.27464.55464.40464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.48464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.87464.32463.87463.82463.74463.98464.37464.30464.05464.28CBWMMBCONC D/WWOOD DECKEL=465.7SPACONC PATIOCONC WALKEXISTING GARAGEFF=464.4GMTR EE #19.3" /5.6"TRE E #712.3"TRE E #23"/3"TRE E #36.5"TRE E #45.8"TRE E #65.1"TRE E #87.4"TRE E #1 014"TRE E #95.8"TRE E #1 128.8"TRE E #1 223"TRE E #1 316.1"TRE E #1 418.8"TREE #1521.2"YNDE CO205382054020552205642057620588205261390420579139171390913901138931388513888 13896LYNDE CTLYNDE AVE111.93 126.59129.2779.0080.0085.00126.7478.2839.2272.09 48.9525.6758.0260.0060.0024.6213.9725.9660.0025.50 34.50 87.00 87.00 87.00 87.00 115.00 74.38 63.97143.00121.8086.4950.8737.59104.4831.42178.01115.61 137.48130.51115.00115.00115.0096.6285.0085.0085.0085.0096.6285.0085.0085.0085.00120.00120.00120.00120.00120.0023.6164.54 29.48156.30NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedA1.002NEIGHBOURHOOD SITE LAYOUT20538, Lynde ct22-SEPT-2022SAGARSUBHENDULynde Ct2055220540205382052613904Lynde Ave20579139091390113893205382052620538205401" = 20'-0"11NEIGHBOURHOOD SITE LAYOUT88 NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedA1.003NEIGHBOURHOOD CONTEXT MAP20538, Lynde ct22-SEPT-2022SAGARSUBHENDU20526ONE STORY, HIP AND GABLE ROOF,WIDE SIDINGCONTEXT MAP20579ONE STORY, HIP AND GABLE ROOF,WIDE HORIZONTAL SIDING20540ONE STORY, HIP AND GABLE ROOF,WIDE BOARD AND BATTEN SIDING20552ONE STORY, HIP AND GABLE ROOF,STUCCO FINISH20538TWO STORY, TPO ROOF,WIDE SIDING13909TWO STORY, HIP AND GABLE ROOF,STUCCO FINISH13901TWO STORY, HIP AND GABLE ROOF,WIDE SIDING13893TWO STORY, HIP AND GABLE ROOF,WIDE SIDING13904ONE STORY, HIP AND GABLE ROOF,WIDE SIDING89 N 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'N0°24'00"W 35.00'BASIS OF BEARINGS5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARK465.91465.60465.51SSMH RIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.17464.50464.24464.46464.90464.20464.16464.22464.20464.31464.27464.55464.40464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.32463.87463.82463.74463.98464.30464.28LYNDE COURTN 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'N0°24'00"W 35.00'BASIS OF BEARINGS5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARK465.91465.60465.51SSMH RIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.17464.50464.24464.46464.90464.20464.16464.22464.20464.31464.27464.55464.40464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.32463.87463.82463.74463.98464.30464.28LYNDE COURTPROPERTY LINELEVEL 2 SETBACK LINE93' - 11 1/2"OHOHOHOHOHSECOND LEVELBUILDING OUTLINECONCRETE DRIVEWAYPROPERTY LINEENTRYCONCRETE OR TILES ON CONCRETECONCRETE OR TILES ON CONCRETEUPNTR-1TR-11TR-1542' - 0"34' - 1 3/4"GMEMJTJTJTJTJTJTSSSSSSSSSSSSSSSSSSSSCO (N)WWWWCONCRETE WALKWAY83' - 10 1/2"NEW WATER METEROPEN PATIOCOVERED PORCHOPEN PORCH4' - 11 3/4"ADJCENT HOUSEADJCENT HOUSEFENCINGAC / HEAT PUMPAC / HEAT PUMPADU1ST LVL PROPSED SETBACK8' - 5"46' - 2 1/4 " 44' - 4 1/ 2 " 25' - 0 3/ 4 "20' - 0"GARAGE115' - 7 1/ 4 "177' - 10"122' - 0 3/4"2ND LVL ALLOWED SETBACK35' - 0"LOT WIDTH82' - 5 3/4"2ND LEVEL PROPOSED SETBACK21' - 6 3/4"2ND LVL PROPOSED SETBACK35' - 0"TREE PROTECTION FENCE20' - 0"1ST LVL PROPOSED ETBACK30' - 10 3/4"2ND LVL PROPOSED SETBACK33' - 7 3/4"DRIVEWAY OPENING21' - 3 1/2"1ST LVL ALLOWED SETBACK8' - 3"2ND LVL PROPOSED SETBACK13' - 3"2ND LVL ALLOWED SETBACK13' - 3"1ST LVL ALLOWED SETBACK25' - 0"1ST & 2ND LVL ALL O WE D SETBACK25' - 0"TR-1TR-3-RTR-7-R12"TR-8-R7.4"TR-9-R5.8"TR-1129"TR-12-R23"TR-13-R16"TR-1419"TR-16-R5"CHERRY LAURELCHERRY LAURELLIQUIDAMABARPEARPLUMOTDEODAR CEDARMODESTO ASHMODESTO ASHMODESTO ASH7"6.5"BLACKACACIATR-4-R6"LEMONMODESTO ASHDOGWOODTR-2-R3"CHERRYLAURELTR-6-R5"TR-5-R 6"BLACKACACIATR-1521"2ND LVL ALLOWED SETBACK13' - 3"1ST LVL PROPSED SETBACK28' - 6"1ST LVL PROPSED SETBACK8' - 5 3/4"1ST LVL ALLOWED SETBACK8' - 3"LOT DE P T H134' - 1 1/4"3' - 0"3' - 0"3' - 0"OUTDOORKITCHENTREE PROTECTIONFENCESECOND STORY FOOTPRINTSETBACK LINESITE LEGENDS :TREE TO BE REMOVEJOINT TRENCHSANITORY SEWERWATER LINEJTJTJTSSSSSSWWW1/8" = 1'-0"1SITE PLANNOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedA1.004SITE LAYOUT20538, Lynde ct22-SEPT-2022SAGARSUBHENDU90 N 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'N0°24'00"W 35.00'BASIS OF BEARINGS5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARK465.91465.60465.51SSMH RIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.76464.17464.50464.24464.46464.90464.20464.27464.31464.44464.16464.20464.25464.12464.19464.77464.35464.30464.31464.31464.08464.55464.40464.41464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.48464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.61464.87464.32463.87463.82463.74463.98464.42464.37464.30464.05464.03464.26464.28NEIGHBORING HOUSECBWMMBCONC D/WWOOD DECKEL=465.7SPACONC PATIOCONC WALKCHIMNEYCONC WALKNEIGHBORING HOUSETREE #19.3"/5.6"TREE #712.3"TREE #23"/3"TREE #36.5"TREE #45.8"TREE #56"TREE #65.1"TREE #87.4"TREE #1014"TREE #95.8"TREE #1128.8"TREE #1223"TREE #1316.1"TREE #1418.8"TREE #1521.2"TREE #176"LYNDE COURTN 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'N0°24'00"W 35.00'BASIS OF BEARINGS5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARK465.91465.60465.51SSMH RIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.76464.17464.50464.24464.46464.90464.20464.27464.31464.44464.16464.20464.25464.12464.19464.77464.35464.30464.31464.31464.08464.55464.40464.41464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.48464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.61464.87464.32463.87463.82463.74463.98464.42464.37464.30464.05464.03464.26464.28NEIGHBORING HOUSECBWMMBCONC D/WWOOD DECKEL=465.7SPACONC PATIOCONC WALKCHIMNEYCONC WALKNEIGHBORING HOUSETREE #19.3"/5.6"TREE #712.3"TREE #23"/3"TREE #36.5"TREE #45.8"TREE #56"TREE #65.1"TREE #87.4"TREE #1014"TREE #95.8"TREE #1128.8"TREE #1223"TREE #1316.1"TREE #1418.8"TREE #1521.2"TREE #176"LYNDE COURTN 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'N0°24'00"W 35.00'BASIS OF BEARINGS5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARK465.91465.60465.51SSMH RIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.76464.17464.50464.24464.46464.90464.20464.27464.31464.44464.16464.20464.25464.12464.19464.77464.35464.30464.31464.31464.08464.55464.40464.41464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.48464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.61464.87464.32463.87463.82463.74463.98464.42464.37464.30464.05464.03464.26464.28NEIGHBORING HOUSECBWMMBCONC D/WWOOD DECKEL=465.7SPACONC PATIOCONC WALKCHIMNEYCONC WALKNEIGHBORING HOUSETREE #19.3"/5.6"TREE #712.3"TREE #23"/3"TREE #36.5"TREE #45.8"TREE #56"TREE #65.1"TREE #87.4"TREE #1014"TREE #95.8"TREE #1128.8"TREE #1223"TREE #1316.1"TREE #1418.8"TREE #1521.2"TREE #176"LYNDE COURTHATCHED AREA TO BE DEMOLISHEDNOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20221/8" = 1'-0"A1.005SITE DEMOLITION20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/8" = 1'-0"1SITE DEMOLITION91 NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20223/64" = 1'-0"A1.006SHADOW ANALYSIS DIAGRAM20538, Lynde ct22-SEPT-2022SHRADHA M.SUBHENDU3/64" = 1'-0"1DECEMBER 21 AT 3.00 PM3/64" = 1'-0"2DECEMBER 21 AT 9.00 AMSHADOW ANALYSIS AT 09:00 AM ON 21ST DECEMBERNNShadow at 09:00 AM falls behind the proposed building.West neighbouring houseLot Area : 11631 sq.ft. Shadow percentage on lot : 7.52 % Shadow Area : 874.88 sq.ft Roof area : 2607 sq.ft. Shadow percentage on roof : 3.20 % Shadow Area : 83.44 sq.ft.SITESHADOW ANALYSIS AT 03:00 PM ON 21ST DECEMBERShadow at 03:00 PM falls on the East side neighbouring house.East neighbouring houseLot Area : 11404 sq.ft. Shadow percentage on lot : 0 % Shadow Area : 0 sq.ft.Roof area : 3036 sq.ft. Shadow percentage on roof : 0 % Shadow Area : 0 sq.ft.EAST NEIGHBOURING HOUSEWEST NEIGHBOURING HOUSEEAST NEIGHBOURING HOUSEWEST NEIGHBOURING HOUSE20538 LYNDE CT 20538 LYNDE CT 92 N 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARKIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.17464.50464.24464.46464.90464.20464.16464.22464.20464.31464.27464.55464.40464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.32463.87463.82463.74463.98464.30464.28LYNDE COURTN 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARKIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.17464.50464.24464.46464.90464.20464.16464.22464.20464.31464.27464.55464.40464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.32463.87463.82463.74463.98464.30464.28LYNDE COURTN 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'5' P.U.E.5' W.C.E.LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27464.33464.70464.86464.73SITE BENCHMARKIM465.46TC465.26TC464.51TC464.42TC464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.17464.50464.24464.46464.90464.20464.16464.22464.20464.31464.27464.55464.40464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.32463.87463.82463.74463.98464.30464.28LYNDE COURTADJCENT HOUSE2A1.007GREAT RO O M BELOW3A1.0078' - 6"2' - 0"20526205388' - 3"1' - 9"2054020538NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedA1.007PRIVACY DIAGRAM20538, Lynde ct22-SEPT-2022SAGARSUBHENDU3/32" = 1'-0"1PRIVACY DIAGRAM - LEVEL 23/16" = 1'-0"2PRIVACY SECTION 13/16" = 1'-0"3PRIVACY SECTION 2ON THE LEFT AND RIGHT SIDE OF THE HOUSE, ALL ARE THE CLERESTORY WINDOWS.FRONT AND REAR SIDE OF THE LOT IS HAVING ROAD VIEWS.NOTE93 ?FOYER8'-9" X 6'-5"PANTRY10'-3" X 10'-0"MUD/LAUNDRY21'-3" X 18'-10"GARAGE11'-10" X 10'-3"OFFICE16'-0" X 13'-6"ADU BEDROOM9'-7" X 4'-3"ADUWALK INCLOSET8'-9" X 5'-6"POWDERROOM4'-0" X 4'-0"ELE13'-7" X 13'-0"ADU LIVINGAREA19'-9" X 17'-5"KITCHEN13'-4" X 11'-3"DINING8'-6" X 5'-2"ADUTOILETUP22'-0" X 13'-4"GREAT ROOM24'-11" X 4'-5"HALLWAY4'-7" X 3'-1"ADU WCOUTDOORKITCHENW01W01W04W01W01W04W02W02W01W02W01W02W02W02W02W01W02W03W01W04RISER -19 NOSTRADE DEPTH -11"RISER HEIGHT -7"FLIGHT WIDTH -3'9"W0115'-7" X 8'-9"ADU KITCHEN43' - 10 1/4"63' - 2 3/4"56' - 9"ENTRYD1D2D2D2D4SLD1SLD3D7SLD4SLD4SLD5D7GDSLD7W1W1SK7SK7AA4.001BA4.001W3W4ADU4'-0" X 2'-3"CLOSET4'-11" X 3'-2"ADU SHR61' - 2 3/4"D2EMGMD6W02W02W03W7W70' - 7" 10' - 0" 1' - 4 1/4" 6' - 0" 0' - 6"0' - 10 1/2"4' - 4 3/4" 1' - 10 1/2" 4' - 4 3/4" 4' - 1 3/4" 11' - 6" 3' - 1" 12' - 0" 2' - 6"20' - 0"20' - 0"0' - 6" 13' - 6"29' - 4 1/4" 0' - 6"COVERED PORCHCONCRETEOR TILES ON CONCRETE PORCHMICROWAVE AND OVENCOLUMN REFRIGERATORCOLUMN FREEZERUNIT WITH BUILT-INCOFFEE MACHINECROKERY UNITDRYERWASHERFULL HEIGHTSTORAGEBENCH WITHDRAWERS BELOW APPLIANCE GARAGEOVER COUNTERTOPUNDER COUNTERREFRIGERATORICE DRAWERSCABINETS3' - 0"3' - 0"D8SLD20' - 6"16' - 0"0' - 4"15' - 6 3/4"0' - 4"5' - 6"0' - 4"6' - 2 3/4"0' - 6"17' - 5 1/4"0' - 6"0' - 6" 4' - 4" 4' - 8" 4' - 4" 10' - 0 1/4" 2' - 6" 17' - 6"0' - 6"6' - 8"0' - 6"20' - 0"0' - 6"10' - 2 1/2"0' - 4"22' - 0 1/4"0' - 6"9' - 7"16' - 2"3' - 2 1/4"8' - 0"1' - 9 1/4"2' - 4 1/2"4' - 0 3/4"2' - 3"2' - 6 1/2"9' - 1"2' - 2 1/2"0' - 10" 14' - 0" 13' - 5" 6' - 3" 12' - 0" 6' - 3" 1' - 3" 2' - 9"0' - 6"53' - 0"0' - 6"2' - 3"0' - 6"W2W2W12W01W133' - 0"TYPICAL 2X6 EXTEROIR WALL @ 16" O.C.TYPICAL 2X4 INTERIOR WALL @ 16" O.C.W01W02W03TYPICAL 2X4 INTERIOR CONCRETE WALL @ 16" O.C.NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedA2.001FIRST FLOOR PLAN20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/4" = 1'-0"1FIRST FLOOR PLANWALL LEGENDSA. ALL PLANS TO BE CONSTRUCTED TO ALL APPLICABLE BUILDING CODES, INCLUDING THE 2019 CBC AND THE CRC.B. THE BUILDING ADDRESS SHALL COMPLY WITH SECTION R319 CRC.C. WALL FRAMING SHALL BE 2x6 AT 16" O.C. WITH 1/2" EXTERIOR SHEATHING AT EXTERIOR WALLS AND 2x4 AT 16" O.C. WITH 5/8" GYP. BOARD AT INTERIOR WALLS. SHEAR WALL PANELS AND SPECIAL FRAMING CONDITIONS WILL BE NOTED IN THE STRUCTURAL DRAWINGS.D. PROVIDE 1/2" GYP. BOARD AT WALLS AND CEILING UNDER STAIR USABLE ENCLOSED SPACES.E. STANDARD DOOR FRAMING SHALL OCCUR 4" FROM RETURN WALL UNLESS OTHERWISE NOTED. HARDWARE PER OWNER.F. ALL EXTERIOR DOORS SHALL HAVE A LANDING WITH A MAXIMUM 7.75" STEP.G. ALL BEDROOMS SHALL HAVE A WINDOW THAT MEETS EGRESS REQUIREMENTS. THIS WINDOW SHALL BE DESIGNATE BY AN (E) AFTER THE WINDOW SIZE AND STYLE. EGRESS WINDOWS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQ FT. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL NOT BE LESS THAN 20 INCHES. GRADE FLOOR AND BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5 SQ FT. EGRESS WINDOWS SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. WINDOWS BELOW GRADE SHALL BE PROVIDED WITH A WINDOW WELL. CRC R310.2H. ALL OTHER WINDOWS SHALL BE OPERABLE UNLESS OTHERWISE SPECIFIED.I. ALL GLAZING IN SLIDING GLASS DOORS, SHOWER ENCLOSURES, AND OTHER REQUIRED SAFETY LOCATIONS SHALL HAVE SAFETY TEMPERED GLASS. CRC R308.4J. BALCONY FLOOR SHALL BE 2" BELOW FINISH FLOOR AND SLOPED 1/4" PER FOOT AWAY FROM DOORS. DOOR OPENINGS SHALL BE PROPERLY FLASHED. DRAINAGE PIPE WILL GO THROUGH FASCIA TO GUTTER.K. EXTERIOR A/C UNITS ARE ANCHORED TO 3" CONCRETE SLABS SHOWN ON PLANS.GENERAL NOTES94 18'-5" X 12'-6"MASTERBEDROOM10'-7" X 9'-6"M. BATH9'-6" X 7'-7"M. WALKINWARDROBE16'-2" X 10'-8"GUESTBEDROOM 220'-4" X 4'-4"TERRACE16'-4" X 8'-3"HALLWAY BELOW4'-0" X 4'-0"ELE16'-3" X 3'-7"PASSAGE9'-0" X 5'-0"BATH 224'-2" X 4'-0"TERRACE6'-6" X 5'-0"CLOSET13'-0" X 12'-0"GUESTBEDROOM 16'-8" X 5'-7"CLOSET9'-0" X 5'-7"BATHDN17'-10" X 7'-6"FAMILY ROOMW03W03W01W01W04W02W02W02W01W02W02W02W02W02W02W01W01W01W02W01TPO ROOFD2D2D2D3D3D3D3D5D5D5D5D6SLD1SLD1SLD7W4W6W6AA4.001BA4.001RISER -19 NOSTRADE DEPTH -11"RISER HEIGHT -7"FLIGHT WIDTH -3'9"4' - 0"W7DOWN SPOUTOVER FLOWSLOPE1/4" PER FT.SLOPE1/4" PER FT.W0224' - 2 1/4"OVERHANGSLOPE - 2" / 1'-0"1' - 6"2' - 0"1' - 6"1' - 6"FIRST LEVEL ROOFW02W03W032' - 0"2' - 0"2' - 8" DOWN SPOUTOVER FLOWCRICKETCRICKE T DOWN SPOUTOVER FLOWCRICKETCRICKET36' - 7 1/2"0' - 6"5' - 0"0' - 4"11' - 0"0' - 4"12' - 10 1/4"0' - 6"5' - 7 1/4"0' - 6"7' - 4"8' - 0"4' - 1 1/4"8' - 0"9' - 2 1/2"43' - 9 3/4"0' - 6" 21' - 10" 0' - 6" 3' - 4" 0' - 4"35' - 11 3/4"0' - 6" 6' - 0" 3' - 6 1/2" 5' - 11 1/2" 2' - 1" 10' - 6" 7' - 5 1/4"10' - 6"0' - 6"20' - 0"0' - 4"9' - 0"0' - 4"6' - 8"0' - 6"11' - 0 1/4"10' - 0"11' - 0 1/4"4' - 6"11' - 3 1/4"5'-5" X 4'-0"CLOSET0' - 6"5' - 4 1/2"0' - 6"12' - 6 3/4"0' - 4"7' - 5 3/4"0' - 6"8' - 3 1/4"0' - 6"SLD3SLD6TYPICAL 2X6 EXTEROIR WALL @ 16" O.C.TYPICAL 2X4 INTERIOR WALL @ 16" O.C.W01W02W03TYPICAL 2X4 INTERIOR CONCRETE WALL @ 16" O.C.NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedA2.002SECOND FLOOR PLAN20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/4" = 1'-0"1SECOND FLOOR PLANWALL LEGENDSA. ALL PLANS TO BE CONSTRUCTED TO ALL APPLICABLE BUILDING CODES, INCLUDING THE 2019 CBC AND THE CRC.B. THE BUILDING ADDRESS SHALL COMPLY WITH SECTION R319 CRC.C. WALL FRAMING SHALL BE 2x6 AT 16" O.C. WITH 1/2" EXTERIOR SHEATHING AT EXTERIOR WALLS AND 2x4 AT 16" O.C. WITH 5/8" GYP. BOARD AT INTERIOR WALLS. SHEAR WALL PANELS AND SPECIAL FRAMING CONDITIONS WILL BE NOTED IN THE STRUCTURAL DRAWINGS.D. PROVIDE 1/2" GYP. BOARD AT WALLS AND CEILING UNDER STAIR USABLE ENCLOSED SPACES.E. STANDARD DOOR FRAMING SHALL OCCUR 4" FROM RETURN WALL UNLESS OTHERWISE NOTED. HARDWARE PER OWNER.F. ALL EXTERIOR DOORS SHALL HAVE A LANDING WITH A MAXIMUM 7.75" STEP.G. ALL BEDROOMS SHALL HAVE A WINDOW THAT MEETS EGRESS REQUIREMENTS. THIS WINDOW SHALL BE DESIGNATE BY AN (E) AFTER THE WINDOW SIZE AND STYLE. EGRESS WINDOWS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQ FT. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL NOT BE LESS THAN 20 INCHES. GRADE FLOOR AND BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5 SQ FT. EGRESS WINDOWS SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. WINDOWS BELOW GRADE SHALL BE PROVIDED WITH A WINDOW WELL. CRC R310.2H. ALL OTHER WINDOWS SHALL BE OPERABLE UNLESS OTHERWISE SPECIFIED.I. ALL GLAZING IN SLIDING GLASS DOORS, SHOWER ENCLOSURES, AND OTHER REQUIRED SAFETY LOCATIONS SHALL HAVE SAFETY TEMPERED GLASS. CRC R308.4J. BALCONY FLOOR SHALL BE 2" BELOW FINISH FLOOR AND SLOPED 1/4" PER FOOT AWAY FROM DOORS. DOOR OPENINGS SHALL BE PROPERLY FLASHED. DRAINAGE PIPE WILL GO THROUGH FASCIA TO GUTTER.K. EXTERIOR A/C UNITS ARE ANCHORED TO 3" CONCRETE SLABS SHOWN ON PLANS.GENERAL NOTES95 AA4.001BA4.001SECOND LEVEL TERRACESECOND LEVELTERRACE BELOWOVERHANGOVERHANGBELOW ROOFDOWN SPOUTOVER FLOWDOWN SPOUTOVER FLOWDOWN SPOUTOVER FLOWSLOPE1/4" PER FT.SLOPE1/4" PER FT.SLOPE1/4" PER FT.SK2SK3SK2OVERHANGCRICKETCRICKET SLOPE - 2" / 1'-0"OVERHANGSLOPE - 2" / 1'-0"1' - 6"TPOTPOGUTTEROVERHANGGUTTER1' - 6"1' - 6"1' - 6"1' - 6 1/4"1' - 6"FIRST LEVEL ROOFSECOND LEVEL ROOFFIRST LEVEL ROOFDOWN SPOUTOVER FLOWCRICKETCRICKE T DOWN SPOUTOVER FLOWCRICKETCRICKET1' - 6"CRICKETCRICKET0' - 6"1' - 6"42' - 6"28' - 1"18' - 6"21' - 0"10' - 6 1/2"24' - 0 1/4"22' - 3 1/2"17' - 4 1/4"57' - 0"5' - 8"41' - 4"21' - 5 1/2"13' - 1 1/2"20' - 2 1/2"19' - 11"5' - 0"12' - 4 3/4"3' - 2"9' - 0"2' - 0"2' - 0"1' - 6"2' - 1 1/4"2' - 0"2' - 0"2' - 8" 1' - 6"NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20221/4" = 1'-0"A2.003ROOF PLAN20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/4" = 1'-0"1ROOF LEVEL PLAN96 LEVEL 1466' -2 1/2"GRADE LEVEL465' -2 1/2"LEVEL 2477' -2 1/2"SLD4SLD5SLD1SLD1SLD3W43' - 0"METAL GUARD RAILSMOOTH STUCCOWITH PAINTSMOOTH STUCCOWITH PAINTSMOOTH STUCCOWITH PAINT1' - 0"10' - 0"1' - 0"464' - 6"464' - 3 3/4"464' - 1"LOWESTEX-GRADEEX-GRADEHIGHESTEX-GRADEEX-GRADE463' - 8 1/2"PROPOSEDGRADE464' - 6"PROPOSEDGRADE464' - 7"AVERAGEEX-GRADEROOF LEVEL487' -8 1/2"TOP OF THE ROOF490' -5 3/4"2' - 9 1/4"10' - 6"HEIGHT OF THE BUILDING25' - 10 3/4"1' - 6"OVERHANGSK2SK31' - 6"OVERHANG1' - 6"OVERHANGW7W7SLOPE - 2" / 1'-0"SLOPE - 2" / 1'-0"477' - 0 1/2"487' - 8 1/2"SK2WOOD FINISHSMOOTH STUCCOWITH PAINTSECOND LEVEL ROOFSECOND LEVEL ROOFFIRST LEVEL ROOFGUTTERGUTTERFIRST LEVEL ROOFW8464' - 2"465' 2 1/2"466' 2 1/2"477' 2 1/2"487' 8 1/2"490' 5 3/4" 0' 0" 1' 0" 12' 0" 22' 6" 25' 4"1' - 6"LEVEL 1466' -2 1/2"GRADE LEVEL465' -2 1/2"LEVEL 2477' -2 1/2"W3W71' - 0"10' - 0"1' - 0"6' - 6"SMOOTH STUCCOWITH PAINTSMOOTH STUCCOWITH PAINTSMOOTH STUCCOWITH PAINT464' - 7 1/4"464' - 6 1/4"464' - 1"EX-GRADEEX-GRADEEX-GRADEEX-GRADE464' - 8 1/2"PROPOSEDGRADE463' - 8 1/2"PROPOSEDGRADE464' - 7"AVERAGEEX-GRADE477' - 2 1/2"ROOF LEVEL487' -8 1/2"TOP OF THE ROOF490' -5 3/4"2' - 9 1/4"10' - 6"HEIGHT OF THE BUILDING25' - 10 3/4"SK2479' - 9"487' - 8 1/2"WOOD FINISHSLOPE - 2" / 1'-0"SECOND LEVEL ROOF490' - 5"490' - 0"SECOND LEVEL ROOFFIRST LEVEL ROOFGUTTERW2W2464' - 1 1/2"465' 2 1/2"466' 2 1/2"477' 2 1/2"487' 8 1/2"490' 5 3/4" 0' 0" 1' 0" 12' 0" 22' 6" 25' 4"1' - 6"2' - 0"2' - 0"OVERHANGOVERHANGW11NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20223/16" = 1'-0"A3.001REAR AND LEFT ELEVATION20538, Lynde ct22-SEPT-2022SAGARSUBHENDU3/16" = 1'-0"1REAR ELEVATION3/16" = 1'-0"2LEFT ELEVATION97 LEVEL 1466' -2 1/2"GRADE LEVEL465' -2 1/2"LEVEL 2477' -2 1/2"1' - 0"9' - 10"1' - 0"GDSK7SK7D1SLD1GMEMMETAL GUARD RAILWOOD FINISHSMOOTH STUCCOWITH PAINT464' - 2 1/2"464' - 1 1/4"464' - 7 1/4"464' - 7 1/4"EX-GRADEEX-GRADEEX-GRADEEX-GRADE464' - 6"464' - 8 1/2"PROPOSEDGRADEPROPOSEDGRADE464' - 8 1/2"PROPOSEDGRADE464' - 8 1/2"PROPOSEDGRADE464' - 4"PROPOSEDGRADE464' - 7"AVERAGE EX-GRADE477' - 2 1/2"ROOF LEVEL487' -8 1/2"SK3SK225' - 10 3/4"2' - 9 1/4"10' - 6"TOP OF THE ROOF490' -5 3/4"SK23' - 0"6' - 3"487' - 8 1/2"SLOPE - 2" / 1'-0"SLOPE - 2" / 1'-0"1' - 6"OVERHANGOVERHANG3' - 6"GUTTERFIRST LEVEL ROOFGUTTERSECOND LEVEL ROOFSECOND LEVEL ROOFW81' - 6"OVERHANGW9W10SLD2465' 2 1/2"466' 2 1/2"477' 2 1/2"487' 8 1/2"490' 5 3/4" 0' 0" 1' 0" 12' 0" 22' 6" 25' 4"1' - 6 1/4"OVERHANG2' - 0"OVERHANGW12SLD3SLD6SMOOTH STUCCOWITH PAINTLEVEL 1466' -2 1/2"GRADE LEVEL465' -2 1/2"LEVEL 2477' -2 1/2"W4W6W6W1W1SLD46' - 6"6' - 6"6' - 6"EMGMSMOOTH STUCCOWITH PAINTSMOOTH STUCCOWITH PAINT1' - 0"10' - 0"1' - 0"464' - 2 1/2"465' - 3"464' - 6"463' - 9"EX-GRADEEX-GRADEEX-GRADEHEIGHESTEX-GRADE464' - 6"PROPOSEDGRADE464' - 8 1/2"PROPOSEDGRADE464' - 6"PROPOSEDGRADE464' - 2 1/2"EX-GRADE464' - 7"AVERAGEEX-GRADE3' - 0"6' - 3"3' - 2"D4480' - 9 1/2"ROOF LEVEL487' -8 1/2"HEIGHT OF THE BUILDING25' - 10 3/4"TOP OF THE ROOF490' -5 3/4"490' - 0"SK3SK2490' - 5"WOOD FINISHSLOPE - 2" / 1'-0"SECOND LEVEL ROOF1' - 6"OVERHANGFIRST LEVEL ROOF2' - 9 1/4"10' - 6"465' 2 1/2"466' 2 1/2"477' 2 1/2"487' 8 1/2"490' 5 3/4" 0' 0" 1' 0"W13NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20223/16" = 1'-0"A3.002FRONT AND RIGHT ELEVATION20538, Lynde ct22-SEPT-2022SAGARSUBHENDU3/16" = 1'-0"1FRONT ELEVATION3/16" = 1'-0"2RIGHT ELEVATION98 LEVEL 1466' -2 1/2"GRADE LEVEL465' -2 1/2"LEVEL 2477' -2 1/2"SLD4D6D3D1PANTRYGUESTBEDROOM 1TERRACEPASSAGEHALLWAY BELOWOFFICE3' - 0"METAL GUARD RAILMETAL GUARD RAIL463' - 8 1/2"PADW02W02W01RISER -19 NOSTRADE DEPTH -11"RISER HEIGHT -7"FLIGHT WIDTH -3'9"464' - 4 1/2"464' - 4 3/4"464' - 2 1/2"464' - 2"LOWEST EX-GRADEEX-GRADEEX-GRADEEX-GRADE464' - 3 1/2"GLASSRAILING466' - 2 1/2"ROOF LEVEL487' -8 1/2"SK2W7TOP OF THE ROOF490' -5 3/4"2' - 9 1/4"1' - 0"2' - 9 1/4"10' - 6"1' - 0"10' - 0"SECOND LEVEL ROOFFIRST LEVEL ROOFFIRST LEVEL ROOFSECOND LEVEL ROOF1' - 6"OVERHANGW10D8D7465' 2 1/2"466' 2 1/2"477' 2 1/2"487' 8 1/2"490' 5 3/4" 0' 0" 1' 0" 12' 0" 22' 6" 25' 4"W11HEIGHT OF THE BUILDING25' - 10 3/4"464' - 7"AVERAGE EX-GRADELEVEL 1466' -2 1/2"GRADE LEVEL465' -2 1/2"LEVEL 2477' -2 1/2"RISER -19 NOSTRADE DEPTH -11"RISER HEIGHT -7"FLIGHT WIDTH -3'9"GREAT ROOMHALLWAYMUD/LAUNDRYADU LIVINGAREAADUWALK INCLOSETADUTOILETHALLWAY BELOWFAMILY ROOMM. WALKINWARDROBEM. BATHD2D5W02W02W02W01W02W02W01W012' - 9 1/4"10' - 6"1' - 0"10' - 0"1' - 0"463' - 8 1/2"464' - 5 1/4"464' - 4 3/4"464' - 4 3/4"PAD464' - 5 1/4"LOWESTEX-GRADELOWESTEX-GRADEEX-GRADEEX-GRADE464' - 7"ROOF LEVEL487' -8 1/2"SK3SECOND LEVEL ROOFFIRST LEVEL ROOF2" 1'-0"2" 1'-0"FIRST LEVEL ROOFSECOND LEVEL ROOF1' - 6"1' - 6"OVERHANGOVERHANGTOP OF THE ROOF490' -5 3/4"1' - 6"OVERHANGD7GUTTER465' 2 1/2"466' 2 1/2"477' 2 1/2"487' 8 1/2"490' 5 3/4" 0' 0" 1' 0" 12' 0" 22' 6" 25' 4"D6HEIGHT OF THE BUILIDING25' - 10 3/4"AVERAGEEX-GRADEW02NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20221/4" = 1'-0"A4.001SECTION A-A & B-B20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/4" = 1'-0"ASECTION A-A1/4" = 1'-0"BSECTION B-B99 4' - 3"D18' - 0"3' - 0"D28' - 0"2' - 8"D39' - 0"3' - 0"D46' - 0"2' - 6"D58' - 0"2' - 6"D6D88' - 0"3' - 8"SLD18' - 0"9' - 1"SLD28' - 0"6' - 0"SLD3 SLD411' - 6"8' - 0"SLD58' - 0"12' - 0"SLD68' - 0"3' - 0"D7SLD79' - 0"16' - 0"GD8' - 0"2' - 6"8' - 0"10' - 6"8' - 0"8' - 0"8' - 0"8' - 0"2' - 8"D96' - 6"3' - 3"D108' - 0"3' - 0"D11NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20223/8" = 1'-0"A5.001DOOR SCHEDULE20538, Lynde ct22-SEPT-2022SAGARSUBHENDUDOOR SCHEDULEMark Count Width Height Head HeightD1 1 4' - 3" 8' - 0" 8' - 0"D2 7 3' - 0" 8' - 0" 8' - 0"D3 4 2' - 8" 8' - 0" 8' - 0"D4 1 3' - 0" 9' - 0" 9' - 0"D5 5 2' - 6" 6' - 0" 6' - 0"D6 3 2' - 6" 8' - 0" 8' - 0"D7 2 3' - 0" 8' - 0" 8' - 0"D8 1 3' - 8" 8' - 0" 8' - 0"D9 1 2' - 8" 8' - 0" 8' - 0"D10 1 3' - 3" 6' - 6"D11 1 3' - 0" 8' - 0" 8' - 0"GD 1 16' - 0" 9' - 0" 9' - 0"SLD1 3 8' - 0" 8' - 0" 8' - 0"SLD2 1 9' - 1" 8' - 0" 8' - 0"SLD3 2 6' - 0" 8' - 0" 8' - 0"SLD4 2 11' - 6" 8' - 0" 8' - 0"SLD5 1 12' - 0" 8' - 0" 8' - 0"SLD6 1 10' - 6" 8' - 0" 8' - 0"SLD7 2 2' - 6" 8' - 0" 8' - 0"6' - 6" 100 W18' - 0"4' - 4"7' - 0"1' - 0"W25' - 4 1/2"14' - 0"1' - 9"3' - 7 1/2"W38' - 6"10' - 0"1' - 9"6' - 9"W4W58' - 6"5' - 0"2' - 0"6' - 6"W6 W78' - 6"4' - 6"2' - 0"6' - 6"3' - 1"3' - 1"SK2SK13' - 1"6' - 1"8' - 0"2' - 3"10' - 0"0' - 3 3/4"4' - 0"22' - 0 1/4"9' - 0 3/4"16' - 0"0' - 4 3/4"3' - 0"W8W91' - 0" 7' - 0"6' - 3"8' - 0"6' - 0"2' - 0"6' - 0"W106' - 6" 2' - 0"10' - 0"8' - 6"W118' - 0"3' - 0"3' - 6"4' - 6"W123' - 0" 5' - 0"8' - 0"4' - 0"W13NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20223/8" = 1'-0"A5.002WINDOW SCHEDULE20538, Lynde ct22-SEPT-2022SAGARSUBHENDUWINDOW SCHEDULEMark Count Width HeightSK1 1 6' - 0" 3' - 0"SK2 2 3' - 0" 3' - 0"W1 3W2 2 6' - 3" 7' - 0"W3 1 14' - 0" 1' - 9"W4 2 10' - 0" 1' - 9"W5 2 2' - 3" 8' - 0"W6 2 5' - 0" 2' - 0"W7 3 4' - 6" 2' - 0"W8 2 16' - 0" 3' - 0"W9 1 22' - 0 1/4" 4' - 0"W10 1 6' - 0" 2' - 0"W11 1 10' - 0" 2' - 0"W12 1 3' - 0" 3' - 6"W13 1 4' - 0" 5' - 0" 101 167 SFH499 SFI431 SFG1283 SFB238 SFA138 SFC132 SFD47 SFJ10 SFK239 SFF177 SFP1207 SFP26' - 8 3/4" 22' - 10 1/4" 21' - 0"9' - 2"21' - 0"2' - 6 3/4"12' - 0 3/4"18' - 5 1/4"12' - 10 3/4" 9' - 3 1/4" 4' - 10" 4' - 4" 22' - 2" 4' - 0"22' - 6 1/4" 10' - 6 1/2" 21' - 0" 7' - 2"511 SFE29 SFL26 SFA470 SFB739 SFC168 SFD4' - 4"6' - 2"20' - 6"12' - 10"4' - 0"30' - 0 1/4"OPEN THROUGHOUT6' - 7 1/4"8' - 9 1/4" 7' - 11 3/4" 12' - 10 3/4" 6' - 4 1/2"4' - 0" 12' - 10" 20' - 6" 10' - 6"28 SFENOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-20221/8" = 1'-0"A6.001AREA CALCULATION20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/8" = 1'-0"1LEVEL 11/8" = 1'-0"2LEVEL 2FIRST LEVEL AREA + SECOND LEVEL AREA = TOTAL FLOOR AREAFIRST LEVEL AREA + PORCH + ADU = TOTAL LOT COVERAGE AREA1,972 + 1431 = 3,403 SF1972 + 384 + 752 = 3,108 SFAREA CALCULATION FOR SECOND FLOORMARK AREA LENGTH AREA WIDTH AREAA 4' - 0" 6' - 7 1/4" 26 SFB 12' - 10" 36' - 7 3/4" 470 SFC 20' - 6" 36' - 0 1/4" 739 SFD 6' - 2" 27' - 3" 168 SFE 4' - 4" 6' - 4 1/2" 28 SFGrand total: 5 1431 SFAREA CALCULATION FOR PORCHMARK AREA LENGTH AREA WIDTH AREAP1 6' - 8 3/4" 26' - 3 1/2" 177 SFP2 6' - 2 1/2" 33' - 4 1/4" 207 SFGrand total: 2 384 SFFLOOR AREA FOR ADU = 752 SFAREA CALCULATION FOR FIRST FLOORMARK AREA LENGTH AREA WIDTH AREAA 12' - 10 3/4" 18' - 5 1/4" 238 SFB 9' - 3 1/4" 30' - 6" 283 SFC 4' - 10" 28' - 6" 138 SFD 4' - 4" 30' - 6" 132 SFE511 SFF 10' - 6 1/2" 22' - 8" 239 SFG1 20' - 6" 21' - 0" 431 SFGrand total: 7 1971 SFAREA CALCULATION FOR ADUMARK AREA LENGTH AREA WIDTH AREAH 7' - 2" 23' - 4 1/4" 167 SFI 21' - 0" 23' - 9 1/4" 499 SFJ 2' - 6 3/4" 18' - 5 1/4" 47 SFK 2' - 0" 4' - 10" 10 SFL 2' - 0" 14' - 6" 29 SFGrand total: 5 753 SF197222' -2"22' -6"752102 EXTERIOR COLOR / MATERIAL SCHEDULEMATERIAL / APPLICATIONCODECOLORMANUFACTUREFLAT ROOFMETAL WINDOW FRAMESWOODEN GARAGE DOORSLIDING GLASS DOORMETAL GUARDRAILM1M3M4M5ROOFWALLMISC.* NOTES: EXACT COLORS TO BE VERIFIED WITH OWNER & ARCHITECTM8M6WHITEBLACKBLACKSMOOTH STUCCO WITH PAINTWHITEWOODEN SIDINGM2CONCRETE WALKWAYM7C.H.I OR EQJELWEN OR EQ.JELWEN OR EQ.GAF OR EQ.--BLACKGREY--WOODEN BROWNWOODEN BROWNACCORDION GLASS DOORM9LA CANTINA OR EQ.BLACKNOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-202212" = 1'-0"A7.001MATERIAL BOARD20538, Lynde ct22-SEPT-2022SAGARSUBHENDUM1M3M4M2FLAT ROOFSMOOTH STUCCO WITH PAINTSLIDING GLASS DOORMETAL WINDOW FRAMEWOODEN SIDINGCONCRETE WALKWAYM5 M6 M7 M8METAL GUARDRAILWOODEN GARAGE DOORM9ACCORDION GLASS DOOR103 GRADING ANDDRAINAGE PLANC-1DATE:SHEET NO.SCALE:DRAWN BY:DESIGNED BY:RW ENGINEERING, INC.DATEBYREVISIONNO.RWSANTA CLARA COUNTY20538 LYNDE COURTSARATOGA, CAAPN: 503-52-012BASIS OF BEARINGS:SITE BENCHMARK:LEGENDABBREVIATIONC-1SWALE2TYPICAL GRADING AROUND FOUNDATIONC-111C-1BUBBLERGMEM.;0&'%1746NPervious PavingConc.or Tiles on Conc.SpaBenchBenchFountainPervious PavingGravelConc.or Tiles on Conc.LawnConcreteDrivewayConc.PathFountainStepsWood Bench104 (TO BE MAINTAINED)STABILIZED CONSTRUCTION ENTRANCEFIBER ROLLEROSIONCONTROL PLANLEGENDHYDROSEEDING:GENERAL EROSION AND SEDIMENT CONTROL NOTES:ADDITONAL NOTES:C-2DATE:SHEET NO.SCALE:DRAWN BY:DESIGNED BY:RW ENGINEERING, INC.DATEBYREVISIONNO.RWSANTA CLARA COUNTY20538 LYNDE COURTSARATOGA, CAAPN: 503-52-012.;0&'%1746NINLET SEDIMENTATION BARRIER105 NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022C-3BEST CONSTRUCTION MANAGEMENT PRACTICE20538, Lynde ct22-SEPT-2022SAGARSUBHENDU106 OHOHOHOHOH25'-0"LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27LYNDE COURTof#2176GREGORY LEWIS LANDSCAPE ARCHITECT736 Park Way Santa Cruz, CA 95065 (831) 359-09601 Driveway - Concrete, color, pattern, and finish to be determined byowner2 Front walkways -Concrete pads, color, pattern, and finishto be determined by owner - Install gray gravel in spaces betweenthem3 Pondless Fountain with 3'x3' underground reservoir in front and4'x4' underground reservoir in rear and gravel on top of grill withadditional splash zone with pond liner sloped back to reservoir.Install GFIC outlet for pump that can be turned on inside houseand also with outside switch on house4 Conc. paving - finish and color to be determined by owner5 Portable spa to be selected by owner with custom concrete or wood skirt on 3 sides6 Custom IPE bench - owner will provide photo7 Conc. or non-slip Tile on Conc. base8 Fountain - similar to #3 above9 Tall narrow square ceramic planters - set on stable concrete orgravel base so they don't tip and lean over time10 Pervious paving - Pervious paver system - pavers to be selectedby owners11 IPE Bench - owner to provide photo12 Lawn sprinklers are min. 24 inches from impervious paving13 3 foot tall horizontal wood fence14 6 foot tall horizontal wood fence15 3' wide x 6' tall horizontal wood gate16 Motorized awning can be extended just when needed17 Outdoor kitchen with grill, sink, burner, fridge, under counter storage, granite counter top, stainless steel storage doors18 Tree protection fence as required in arborist report - 6' high chainlink with 2 inch dia. steel posts driven min. 24 inches into groundand spaced no more than 10 feet apart - see most recent versionof Arborist Report by Kielty Arborist Services LLC kkarbor0476@yahoo.comlewislandscape@sbcglobal.net"I have complied with the criteria of the Water Conservation in Landscaping Ordinance and appliedthem for the efficient use of water in the landscape design plan"Gregory Lewis - Landscape Architect Lic. #2176 6/24/22Hydrozone Table3/30/22Tree ProtectionFencing4/25/22Setbacks, housemoved on my planHydroz numbersfysb numbers6/24/22House plan, paving107 .;0&'%1746 20538 LYNDE COURTSARATOGA, CATOPOGRAPHIC& BOUNDARYSURVEYSANTA CLARA COUNTYDATE:SHEET NO.SCALE:DRAWN BY:DESIGNED BY:RW ENGINEERING, INC.DATEBYREVISIONNO.OF SHEETSRWAPN: 503-52-012SU-1BASIS OF BEARINGS:SITE BENCHMARK:NOTES:ABBREVIATIONLEGENDSITE DATA:N108 NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022T-1TREE PROTECTION INSTRUCTION20538, Lynde ct22-SEPT-2022SAGARSUBHENDU109 NOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500NREVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022T-2TREE PROTECTION INSTRUCTION20538, Lynde ct22-SEPT-2022SAGARSUBHENDU110 LOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27LYNDE COURTLOT 11TRACT 3259151 MAPS 27LOT 13TRACT 3259151 MAPS 27LYNDE COURTPROPERTY LINELEVEL 2 SETBACK LINE93' - 11 1/2"SECOND LEVELBUILDING OUTLINECONCRETE DRIVEWAYPROPERTY LINEENTRYCONCRETE OR TILES ON CONCRETECONCRETE OR TILES ON CONCRETENTR-1TR-3-RTR-7-R12"TR-8-R7.4"TR-9-R5.8"TR-1129"TR-12-R23"TR-13-R16"TR-1419"TR-16-R5"CHERRY LAURELCHERRY LAURELLIQUIDAMABARPEARPLUMOTDEODAR CEDARMODESTO ASHMODESTO ASHMODESTO ASH25' - 0"GMEMSSSSSSWWWWCONCRETE WALKWAY83' - 10 1/2"PROPOSED MAIN HOUSE7"6.5"BLACKACACIATR-4-R6"LEMONTREE PROTECTION AREATREE PROTECTION AREACOVERED PATIOOPEN PATIOCOVERED PORCHOPEN PORCHMODESTO ASHDOGWOODTR-2-R3"CHERRYLAURELTR-6-R5"TR-5-R 6"BLACKACACIATR-1521"AC / HEAT PUMPAC / HEAT PUMPOUTDOORKITCHENTABLETREESIZENOTETR1TR2TR3TR4TR5TOTAL NUMBER OF TREES EXISTED AT SITE - 17 NOSTR6NAME OF TREECHERRY LAURELDOGWOODLIQUIDAMBARPEARPLUMOTDEODAR CEDARSILVER MAPLETR7TR8TR9TR10TR11TR12HOLLY OAKSTO BE REMOVEDBLACK ACACIATO BE REMOVEDTO BE REMOVEDTO BE REMOVEDTO BE REMOVEDPROTECTEDOUT OF THE LOTPROTECTEDTREE PORTECTION NOTE:TREE PROTECTION FENCING AROUNDTREE NOS. 1,2,11,12,13,14,15CHERRY LAURELCHERRY LAURELBLACK ACACIAMODESTO ASHLEMONPERSIMMONTR13TR14TR15TR16TR17PROTECTEDPROTECTEDMODESTO ASHMODESTO ASHTO BE REMOVEDTO BE REMOVEDOUT OF THE LOTTO BE REMOVED9.3"3"6.5"5.8"6"5.1"12.3"7.4"5.8"14"28.8"23"16.1"18.8"21.2"4.2"6"TO BE REMOVEDTO BE REMOVEDTO BE REMOVEDSECOND STORY FOOTPRINTSETBACK LINESITE LEGENDS :TREE TO BE REMOVEJOINT TRENCHSANITORY SEWERWATER LINEJTJTJTSSSSSSWWWNOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedT-3TREE PROTECTION PLAN20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/8" = 1'-0"1TREE PROTECTION PLAN111 N 49°47'51" E 178.01'N 69°38'22" E 115.61'N0°24'00"W 121.80'Δ=81D51'04"L=60.00'R=42.00'5' P.U.E.5' W.C.E.464.33464.7086464.73SITE BENCHMARK465.46TC465.26TC464.51TC4.42464.91TC465.14465.00464.88464.84464.84464.60464.89464.53464.76464.17464.50464.24464.46464.90464.20464.27464.44464.16464.22464.20464.25464.12464.19464.77464.35464.30464.31464.31464.08464.27464.55464.40464.41464.65464.68464.49464.38464.40464.17464.50464.12464.21464.10464.12464.63464.55464.57464.48464.02464.27464.37464.39464.40464.37464.32464.25464.24464.22463.66463.13463.49463.74463.55463.28462.91463.13462.64462.41462.84463.83464.66464.48464.59464.61464.87464.32463.87463.82463.74463.98464.42464.37464.30464.05464.03464.26464.28DE COURTPROPERTY LINELEVEL 1 SETBACK LINELEVEL 2 SETBACK LINE93' - 11 1/2"OHOHOHOHOHSECOND LEVELBUILDING OUTLINECONCRETE DRIVEWAYPROPERTY LINEENTRYCONCRETE OR TILES ON CONCRETECONCRETE OR TILES ON CONCRETEUPNGMEMJTJTJTJTJTJTSSSSSSSSSSSSSSSSSSSSCO (N)WWWWCONCRETE WALKWAY83' - 10 1/2"JTCOVERED PATIOOPEN PATIOCOVERED PORCHOPEN PORCH122' - 0 1/2"115' - 7 1/ 4 "AC / HEAT PUMPAC / HEAT PUMPOUTDOORKITCHENSECOND STORY FOOTPRINTSETBACK LINESITE LEGENDS :TREE TO BE REMOVEJOINT TRENCHSANITORY SEWERWATER LINEJTJTJTSSSSSSWWWNOTES:NOTES:• ALL DIMENSIONS ARE IN FEET AND INCHES.• DRAWING SHALL NOT BE SCALED AND ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.• ALL CENTERLINES ARE FROM THE CENTER OF COLUMN/ WALL AND THE DIMENSIONS GIVEN ARE CENTERLINE DIMENSIONS- -UNLESS OTHERWISE MENTIONED.• IN CASE OF ANY DISCREPANCY FOUND IN DRAWINGS AND DETAILS, IT SHALL BE BROUGHT TO THE NOTICE OF THE ARCHITECT, AND RECTIFIED, PRIOR TO ITS EXECUTION.• THIS DRAWING IS ISSUED STRICTLY WITH AN UNDERSTANDING THAT IT WILL BE USED ONLY FOR THE PURPOSE MENTIONED AND SHALL BE RETURNED AFTER COMPLETION.• ·LARGER SCALE DRAWINGS AND DETAILS SUPERCEDE THE SMALLER SCALE DRAWINGS AND DETAILS.• THIS DRAWING SHALL BE REFERRED ONLY FOR THE PURPOSE MENTIONED IN ITS TITLE (FLOORING PATTERN, FALSE CEILING, SHUTTERING PATTERN, ELECTRICAL, PLUMBING, ETC.)REVISIONS :REV.DESCRIPTIONDATE REVISED BYDATE:DRAWN BY:CHECKED BY:SHEET NO:SCALE:ADDRESS :329 S San Antonio Road Suite #4, Los Altos, CA 94022CONTACT :EMAIL :team@golivio.comPROJECT :THIS DOCUMENT IS THE PROPERTY OF LIVIO BUILDING SYSTEMS AND SHALL NOT BE REFERRED, REPRODUCED, COPIED, ETC, WITHOUT EXPLICIT WRITTEN PERMISSION FROM LIVIO BUILDING SYSTEMS, LOS ALTOS, CA USA650-209-6500REVISED AS PER COMMENTSSAGAR126-APR-2022REVISED AS PER COMMENTSSAGAR229-JUNE-2022REVISED AS PER COMMENTSSAGAR303-AUGUST-2022As indicatedU-1UTILITY PLAN20538, Lynde ct22-SEPT-2022SAGARSUBHENDU1/8" = 1'-0"1UTILITY PLAN112 REPORT TO THE PLANNING COMMISSION 20196 Franklin Avenue Meeting Date: October 12, 2022 Application: APTR22-0001; TRP22-0227 Address/APN: 20196 Franklin Ave / APN 393-39-009 Property Owner/Appellants: Jiabin Zhao From: Debbie Pedro, Community Development Director Report Prepared By: Christina Fusco, City Arborist 113 Report to the Planning Commission 20196 Franklin Avenue – Application APTR22-0001; TRP22-0227 October 12, 2022 Page | 2 PROJECT DESCRIPTION The property owner of 20196 Franklin Avenue has appealed an administrative decision to deny an application for the removal of a 48” coast redwood (Sequoia sempervirens) in the front yard. STAFF RECOMMENDATION Adopt Resolution No.22-022 denying the appeal. Pursuant to City Code Section 15-50.100(a), review by the Planning Commission is required for an appeal of an administrative decision. SITE CHARACTERISTICS AND APPEAL DESCRIPTION Site Description The property is a single-story house in a residential neighborhood at the end of Franklin Avenue. The subject tree is in a central and prominent location in the front yard. Background and Reason for Appeal On July 6, 2022, property owner Jiabin Zhao applied for a permit (TRP22-0227) to remove one coast redwood growing in the front yard. The reason for the requested removal of the redwood was that it is lifting the driveway and the tree roots may be too close to the foundation of the home. (Attachment 1) On August 2, 2022, staff conducted a site visit to inspect the tree requested for removal. The 48” trunk diameter redwood tree, approximately 60’-70’ tall, was determined to be in fair health. If the redwood is maintained, it can be expected to live another fifty or more years. The tree currently has three leaders originating from a limb failure that took place 10-15 years ago. The tree has had vigorous growth since then and appears to be recovering well. The tree is located approximately 18.5’ from the front of the house and 9.5’ from the existing driveway. There is no evidence of damage or threatened damage to the home foundation. The driveway is aging asphalt with cracks throughout the length of the driveway, most of which do not appear related to the tree. One root appears to be causing lifting of the driveway at a location approximately 10 feet from the tree. This root could be cut 8 feet from the tree without compromising the health or stability of the tree. On August 23, 2022, the application was denied because the tree removal criteria in City Code Section 15-50.080 could not be met, and staff had a subsequent meeting with the owner to explain the reasons for permit denial. It was recommended to the homeowner to have an ISA Certified Arborist with a Tree Risk Assessment Qualification evaluate the tree leaders if there are concerns about future tree failure. On September 7, 2022, an application to appeal the administrative determination denying the application for tree removal was filed with the Community Development Department. (Attachment 2) 114 Report to the Planning Commission 20196 Franklin Avenue – Application APTR22-0001; TRP22-0227 October 12, 2022 Page | 3 FINDINGS The findings required for tree removal pursuant to City Code Section 15-50.080 are set forth below. The Appellant has not met the burden of proof to support making one or more of those required findings: (1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. This finding cannot be made. The redwood tree was determined to be in fair to good health. (2) The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. This finding cannot be made. The tree is located approximately 18.5’ from the front of the house and 9.5’ from the existing driveway. There was no evidence of damage or threatened damage to the home. The area of the driveway being lifted by a tree root can be mitigated without removing the tree. (3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. This finding is not applicable because the property is considered flat and erosion control is not a concern. (4) The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. This finding cannot be made. The redwood is a central and large tree in the front yard and is prominently visible from Franklin Avenue and surrounding streets. It contributes to shade, privacy, and the aesthetic appearance of the property. (5) The age and number of healthy trees the property is able to support according to good forestry practices. This finding cannot be made. The redwood is not crowded by other trees and the property can accommodate this tree. (6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. This finding cannot be made because there are alternatives to the removal of the tree. The portion of the driveway closest to the tree can be protected through root pruning or modifications to the driveway during repair or replacement. 115 Report to the Planning Commission 20196 Franklin Avenue – Application APTR22-0001; TRP22-0227 October 12, 2022 Page | 4 (7) Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. This finding cannot be made. The general purpose of the Article is to preserve mature trees in good condition. (8) Any other information relevant to the public health, safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010. This finding cannot be made as the tree does not affect public safety. (9) The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. This finding cannot be made as there are no current applications for property improvements. (10) The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. This finding is not applicable as solar panels are not proposed. ATTACHMENTS 1. Resolution No. 22-022 denying the appeal 2. Tree removal permit application TRP22-0227 3. Appeal application APTR22-0001 116 RESOLUTION NO: 22-022 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION DENYING APPEAL APTR22-0001 AND TREE REMOVAL PERMIT APPLICATION TRP22-0227 AT 20196 FRANKLIN AVENUE WHEREAS, the City of Saratoga Planning Commission has received an appeal of an Administrative Decision denying a request to remove one coast redwood at 20196 Franklin Avenue; and WHEREAS, the Planning Commission held a duly noticed public hearing at which time all interested parties were given a full opportunity to be heard and present evidence; and WHEREAS, the goal of the City is to balance the rights and privileges of property owners for the use of their land with criteria for establishing and sustaining an urban forest, including the establishment of basic standards and criteria for the removal and replacement of trees; and WHEREAS, after considering all of the criteria for the application of a Tree Removal Permit set forth in Section 15-50.080, the Planning Commission finds that overall the applicant has not met the burden of proof required to support said application for the Tree Removal Permit for one coast redwood. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The administrative decision is consistent with the General Plan, Open Space and Conservation Element Policy: General Open Space, OSC2: To preserve the City’s existing character which includes small town residential, rural/semi-rural areas and open spaces. The mature redwood on the property adds to the small town residential semi-rural appeal of the community. Arbor Resources Element, OSC12: Support appropriate management for sustaining the health and increasing the extent of arbor resources in the City. The specific vision is to increase overall tree cover, tree health and consequent tree benefits in an equitable, cost beneficial and sustainable manner. To further protect and enhance the City’s arbor resources built on the City’s Tree Regulations, the City should continue its support of tree protection programs. 117 20196 Franklin Avenue Application #: APTR22-0001/TRP22-0227 Resolution No. 22-022 Page | 2 The coast redwood was requested for removal through the City’s process to remove protected trees as set forth in the Tree Regulations. The Planning Commission has reviewed the application for tree removal and the appeal and found that the request to remove the coast redwood does not meet the criteria in the City Code, overall. Section 3: The administrative decision is consistent with the Saratoga City Code Section 15-50.080 in that the tree appears healthy, stable and does not appear to be damaging structures on the property on which it grows or the neighbor’s property. Criteria 1, 2, 4, 5, 6, 7, 8 and 9 have not been met. Criteria 3 and 10 do not apply. How each criterion has or has not been met is detailed below. (1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. This finding cannot be made. The redwood tree was determined to be in fair to good health. (2) The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. This finding cannot be made. The tree is located approximately 18.5’ from the front of the house and 9.5’ from the existing driveway. There was no evidence of damage or threatened damage to the home. The area of the driveway being lifted by a tree root can be mitigated without removing the tree. (3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. This finding is not applicable because the property is considered flat and erosion control is not a concern. (4) The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. This finding cannot be made. The redwood is a central and large tree in the front yard and is prominently visible from Franklin Avenue and surrounding streets. It contributes to shade, privacy, and the aesthetic appearance of the property. (5) The age and number of healthy trees the property is able to support according to good forestry practices. This finding could not be made. The coast redwood is not crowded by other trees and the property can accommodate this tree. (6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. This finding cannot be made because there are alternatives to the removal of the tree. The portion of the driveway closest to the tree can be protected through root pruning or modifications to the driveway during repair or replacement. (7) Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. This finding cannot be made. The general purpose of the Article is to preserve mature trees in Saratoga. 118 20196 Franklin Avenue Application #: APTR22-0001/TRP22-0227 Resolution No. 22-022 Page | 3 (8) Any other information relevant to the public health, safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010. This finding cannot be made as the tree does not affect public safety. (9) The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. This finding cannot be made as there are no current applications for property improvements. (10) The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. This finding is not applicable as solar panels are not proposed. Section 4: Unless appealed to the City Council pursuant to the requirements of Article 15-90 of the Saratoga City Code, this Resolution shall become effective fifteen (15) days from the date of adoption. The City of Saratoga Planning Commission hereby denies APTR22-0001, denying TRP22-0227 for the removal and replacement of one coast redwood, located at 20196 Franklin Avenue. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 12th day of October 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Herman Zheng Chair, Planning Commission 119 120 121 122 123 124 125 126 127 128 REPORT TO THE PLANNING COMMISSION 19518 Glen Una Drive Meeting Date: October 12, 2022 Application: PDR21-0023/ARB21-0084 Address/APN: 19518 Glen Una Drive / 510-06-066 Applicant / Property Owner: Cherine Bassal / Sanjay Banerjee and Anuja Sehgal From: Debbie Pedro, Community Development Director Report Prepared By: Christopher Riordan, Senior Planner 129 Report to the Planning Commission 19518 Glen Una Drive– Application # PDR21-0023/ARB21-0084 October 12, 2022 Page | 2 PROJECT DESCRIPTION The applicant is requesting Design Review approval for a first and second story addition to an existing 4,241 square foot two story residence for a total floor area of 6,870 square feet. The project will include a detached 430 square foot pool cabana and a swimming pool. An existing 501 square foot detached garage will be removed. Four protected trees are proposed for removal which include a Deodar Cedar, Coast Live Oak, Camphor, and a Ficus. STAFF RECOMMENDATION Adopt Resolution No. 22-019 approving the project subject to conditions of approval included in Attachment 1. Pursuant to City Code Section 15-45.060(a)(6), Design Review Approval by the Planning Commission is required as the project will increase the cumulative floor area of all structures on the site to more than 6,000 square feet. PROJECT DATA Gross/Net Site Area: 118,660 sq. ft. gross (2.74 acres) / 117,310 sq. ft (2.69 acres) Average Site Slope: 13% General Plan Designation: RVLD (Residential Very Low Density) Zoning: R-1-40,000 Proposed Allowed/Required Site Coverage House and Garage Cabana Porches/Decks/Walks Driveway Pool and pool deck Permeable Walkway Total Proposed 4,780 sq. ft. 430 sq. ft. 2,230 sq. ft. 8,132 sq. ft. 1,515 sq. ft. 1,564 sq. ft. 18,651 sq. ft. (15.8%) 41,531 sq. ft. (35%) Floor Area First Floor Second Floor Attached Garage Cabana ADU Total Floor Area 4,155 sq. ft. 2,090 sq. ft. 625 sq. ft. 430 sq. ft. 1,200 sq. ft 8,500 sq. ft. 8,500 sq. ft.* Height 26’-0” 26’ Setbacks Front: Left Side: Right Side Rear: 1st Floor 58’4” 29’0” 45’6” 380’0” 2nd Floor 28’8” 16’6” 32’7” 39’2” 1st Floor 30’ 20’ 20’ 50’ 2nd Floor 25’ 25’ 25’ 60’ Grading Cut 104 CY Fill 145 CY Export 41 CY No grading limit in the R-1-40,000 zoning district * Includes one-time 800 square foot allowance for ADU per City code Section 15-56.025(5)(b) and 10% floor area bonus for deed restricted ADU. 130 Report to the Planning Commission 19518 Glen Una Drive– Application # PDR21-0023/ARB21-0084 October 12, 2022 Page | 3 SITE CHARACTERISTICS AND PROJECT DESCRIPTION Site Description The 2.74-acre project site is located at 19518 Glen Una Drive and is approximately 500 feet south of the intersection of Saratoga-Los Gatos Road and Glen Una Drive. Land uses surrounding the project site include a combination of both one- and two-story single-family homes on similar sized parcels. The site contains an existing two-story residence with a Monterey architectural style and a detached two car garage. The average slope of the site is 13%. A total of 29 protected trees are located in the vicinity of the project site which include Coast Live Oaks, Camphor’s, and Coast Redwoods. Project Description The project will consist of an interior remodel and both a first and second story addition which will include adding 2,439 sq. ft. to the first story and 190 sq. ft. to the second story for a total square footage of 6,870 square feet. A roof terrace at the rear of the structure will be located above the first story addition. A 430 square foot, 15 feet tall, detached cabana and a swimming pool will be located in the southerly portion of the site in an area that is currently not developed with any structures. The existing 490 square feet detached garage will be removed. The Building Department is reviewing development plans under a separate permit for the construction of a 1,200 square foot one-story accessory dwelling unit (ADU) to be located in approximately the same location as the existing detached garage that is to be removed. Permits for the construction of ADUs are processed ministerially by the Building Department. All structures including the ADU, cabana, and the main residence will have a unifying architectural theme. For reference, a copy of the site plan and elevations for the ADU are included as Attachment #6. As mentioned previously, the existing residence has a Monterey architectural style. The project will modify the architectural style so that the remodeled residence has an architectural style that can best be described as Spanish Revival. The projects architectural features to support the architectural style include a low-pitched roof, little or no eave overhang, a red tile roof covering, a prominent arch placed above the entrance door, a stucco exterior, and an asymmetrical façade. The 430 square foot cabana will have the same architectural style and architectural detailing as the main residence. The applicant has provided a color and materials board (Attachment #5). Below is a list of the proposed exterior materials. Detail Colors and Materials Exterior Tan Colored Stucco Windows Charcoal Colored Double Hung Wood Windows Doors Wood Patio Doors with Transom Metal and Glass Entrance Door Roof Red and Brown Colored Mission Tiles 131 Report to the Planning Commission 19518 Glen Una Drive– Application # PDR21-0023/ARB21-0084 October 12, 2022 Page | 4 Trees The project arborist inventoried a total of 58 trees on site. As determined by the City Arborist, four (4) protected trees that are in either deceased or conflict with location of the required fire truck turnaround are recommended for removal. These trees include a Deodar Cedar, a Coast Live Oak, a Camphor, and a Ficus. All remaining protected trees will be fenced and preserved prior to building permit issuance and throughout the duration of the project. Tree protection fencing is required to be installed prior to the issuance of building permits. Details of the arborist’s findings and description of the trees to be removed and those trees to be preserved are included in the Arborist Report. (Attachment 2) Landscaping The front yard landscaping is dominated by existing mature trees that are to be retained including Coast Live Oaks, Camphor, Japanese Maples, and Privet. Existing areas of ornamental landscaping and turf are to remain. The existing asphalt driveway will be replaced with permeable pavers. FINDINGS The findings required for issuance of a Design Review Approval pursuant to City Code Section Article 15-45.080 are set forth below and the Applicant has met the burden of proof to support making all of those required findings: a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be primarily limited to expanding the size of the existing building pad to accommodate the first story addition and creating level areas for the detached cabana, pool, and related decking and walkways. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the number of trees to be removed is limited to three trees which were evaluated by the City Arborist to be deceased or conflict with the location of the fire truck turnaround area. Tree protection fencing is required to be installed prior to the issuance of building permits and shall remain in place for project duration. c. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. 132 Report to the Planning Commission 19518 Glen Una Drive– Application # PDR21-0023/ARB21-0084 October 12, 2022 Page | 5 This finding can be made in the affirmative in that the second story windows facing the neighboring property owners are relatively few in number and smaller in size. Privacy impacts of the roof terraces are mitigated by the views being directed toward Glen Una Drive and the rear yard with the distance to nearest rear residence being greater than 350 feet. Existing landscaping along the perimeter of the site offers additional privacy screening. No community view sheds are in the vicinity of the project. d. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the second story has a proposed height that does not exceed the maximum allowable height for a single-family residence and proposed setbacks that are greater than the minimum required by the zoning district. The second story windows on the second floor and relatively few in number, small in size, and the distance from both the adjacent residences and existing landscaping along the property lines will help mitigate privacy impacts. No community viewsheds are located in the vicinity of the project. to reduce the perception of mass. The architectural elements of the structure are true to the Spanish Revival style with architectural forms and detailing to reduce the perception of mass. e. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the hardscape within the 30-foot front setback area containing existing trees and ornamental landscaping that complement the neighborhood streetscape. The existing asphalt driveway will be removed and replaced with permeable pavers. f. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing, the project meets or exceeds required setbacks, and the orientation of the sun with respect to the location of the site will not cast shadows on adjoining properties. g. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative because the proposed project incorporates applicable design policies and techniques from the Residential Design Handbook. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. 133 Report to the Planning Commission 19518 Glen Una Drive– Application # PDR21-0023/ARB21-0084 October 12, 2022 Page | 6 h. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. The lot is not zoned Hillside Residential but does have an average slope in excess of 10% so it is classified as a hillside lot. There are no ridgelines, community viewsheds, or significant hillside features in the vicinity of the project. The project is also compliant with the residential structure height limits contained within Section 15-13.100. Neighbor Notification and Correspondence The applicant contacted adjacent neighbors regarding the project and was able to obtain three (3) completed neighborhood review forms (Attachment #3). None of the submitted form contained project related comments. The Community Development Department mailed public notices to property owners within 500 feet of the site. In addition, the public hearing notice and description of the project was published in the Saratoga News. ENVIRONMENTAL DETERMINATION The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3 (a) of the Public Resources Code (CEQA). This exemption allows for the construction of three single-family residences in a residential area. The project, as proposed, is for the construction of a new residence in a suburban, residential area. ATTACHMENTS 1. Resolution No. 22-019 2. Arborist Report dated July 21, 2022 3. Neighbor Comments and Project Notification Forms 4. Story Pole Certification 5. Materials Board 6. ADU plans for reference 7. Project Plans 134 RESOLUTION NO: 22-019 A RESOLUTION OF THE CITY OF SARATOGA PLANNING COMMISSION APPROVING DESIGN REVIEW PDR21-0023 AND ARBORIST REPORT ARB21-0084 19518 GLEN UNA DRIVE (APN 510-06-066) WHEREAS, on August 11, 2021, an application was submitted by Cherine Bassal AIA (Applicant) on behalf of Sanjay Banerjee and Anuja Sehgal (Owners) requesting Design Review approval for a first and second story addition to an existing 4,241 square foot two story residence for a total floor area of 6,870 square feet. The project will include a detached 430 square foot pool cabana and a swimming pool. The existing 501 square foot detached garage will be removed. Four protected trees are proposed for removal which include a Deodar Cedar, Coast Live Oak, Camphor, and a Ficus. The site is located in the R-1-40,000 zoning district. WHEREAS, the Community Development Department completed an environmental assessment for the project in accordance with the California Environmental Quality Act (CEQA) and recommends that the Planning Commission determine this project Categorically Exempt. WHEREAS, on October 12, 2022 the Planning Commission held a duly noticed public hearing on the subject application, and considered evidence presented by City Staff, the applicant, and other interested parties. NOW THEREFORE, the Planning Commission of the City of Saratoga hereby finds, determines, and resolves as follows: Section 1: The recitals set forth above are true and correct and incorporated herein by reference. Section 2: The project is Categorically Exempt from the Environmental Quality Act (CEQA) pursuant Section 15303, “New Construction or Conversion of Small Structures”, Class 3(a) of the Public Resources Code (CEQA). This exemption allows for the construction of a single- family residence and small structures in a residential area. Section 3: The proposed residence is consistent with the following Saratoga General Plan Policies: Land Use Goal 13 which provides that the City shall use the Design Review process to assure that the new construction and major additions thereto are compatible with the site and the adjacent surroundings; Safety Element Site and Drainage Policy 3 which provides that the City shall require that landscaping and site drainage plans be submitted and approved during Design Review for a residence prior to issuance of permits; and Conservation Element Policy 6.0 which provides that the City shall protect the existing rural atmosphere of Saratoga by carefully considering the visual impact of new development. Section 4: The proposed residence is consistent with the Saratoga City Code in that the design and improvements are consistent with the design review findings. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints; the porch and entry are in scale with other structures in the 135 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 2 neighborhood. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. Section 5: The City of Saratoga Planning Commission hereby approves PDR21- 0023/ARB21-0084, 19518 Glen Una Drive (APN 510-06-066), subject to the Findings, and Conditions of Approval attached hereto as Exhibit 1. PASSED AND ADOPTED by the City of Saratoga Planning Commission on this 12th day of October 2022 by the following vote: AYES: NOES: ABSENT: ABSTAIN: ____________________________ Herman Zheng Chair, Planning Commission 136 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 3 Exhibit 1 CONDITIONS OF APPROVAL PDR21-0023 / ARB21-0084 19518 GLEN UNA DRIVE (APN 510-06-066) GENERAL 1. All conditions below which are identified as permanent or for which an alternative period of time for applicability is specified shall run with the land and apply to the landowner’s successors in interest for such time period. No zoning clearance, or demolition, grading for this project shall be issued until proof is filed with the city that a certificate of approval documenting all applicable permanent or other term-specified conditions has been recorded by the applicant with the Santa Clara County Recorder’s office in form and content to the Community Development Director. If a condition is not “Permanent” or does not have a term specified, it shall remain in effect until the issuance by the City of Saratoga of a Certificate of Occupancy or its equivalent. 2. The Owner and Applicant will be mailed a statement after the time the Resolution granting this approval is duly executed, containing a statement of all amounts due to the City in connection with this application, including all consultant fees (collectively “processing fees”). This approval or permit shall expire sixty (60) days after the date said notice is mailed if all processing fees contained in the notice have not been paid in full. No Zoning Clearance or Demolition, Grading, or Building Permit may be issued until the City certifies that all processing fees have been paid in full (and, for deposit accounts, a surplus balance of $500 is maintained). 3. The Project shall maintain compliance with all applicable regulations of the State, County, City and/or other governmental agencies having jurisdiction including, without limitation, the requirements of the Saratoga City Code incorporated herein by this reference. 4. As a condition of this Approval, Owner and Applicant hereby agree to defend, indemnify, and hold the City and its officers, officials, boards, commissions, employees, agents and volunteers harmless from and against: a. any and all claims, actions or proceedings to attack, set aside, void or annul any action on the subject application, or any of the proceedings, acts or determinations taken, done or made prior to said action; and b. any and all claims, demands, actions, expenses or liabilities arising from or in any manner relating to the performance of such construction, installation, alteration or grading work by the Owner and/or Applicant, their successors, or by any person acting on their behalf. 137 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 4 In addition, prior to any Zoning Clearance, Owner and Applicant shall execute a separate agreement containing the details of this required Agreement to Indemnify, Hold Harmless and Defend, which shall be subject to prior approval as to form and content by the City Attorney. COMMUNITY DEVELOPMENT DEPARTMENT 5. PERMANENT CONDITION - The owner shall restrict the rental of the accessory dwelling unit to only households that qualify as low, very-low, or extremely-low income households as those terms are defined in the most recent Santa Clara County Housing and Urban Development Program Income Limits or, in the event that the most recent such report is more than five years old, in accordance with the definitions set forth in Health and Safety Code section 50079.5, 50105, and 50106 as those sections exist as of the effective date of this restriction. “Rental” means any agreement whereby the occupant(s) of the accessory dwelling unit make any payment in consideration of said occupancy. The Deed Restriction document shall be notarized and recorded with the County of Santa Clara Clerks Office, prior to issuance of building permit. 6. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 7. The development shall be located and constructed to include those features, and only those features as shown on the plans approved by the Planning Commission. All proposed changes to the approved plans must be submitted in writing with plans showing the changes, including a clouded set of plans highlighting the changes. Such changes shall be subject to approval in accordance with City Code. 8. Prior to issuance of Building Permits, the applicant shall submit for staff approval, a Lighting Plan for the home’s exterior and landscaped areas. Proposed exterior lighting shall be limited to full cut off & shielded fixtures with downward directed illumination so as not to shine on adjacent properties or public right-of-way. All proposed exterior lighting shall be designed to limit illumination to the site and avoid creating glare impacts to surrounding properties. 9. To comply with standards that minimize impacts to the neighborhood during site preparation and construction, the applicant shall comply with City Code Sections 7-30.060 and 16-75.050, with respect to noise, construction hours, maintenance of the construction site and other requirements stated in these sections. 10. Prior to issuance of Building Permits, the applicant shall prepare for review and approval by City staff a Construction Management Plan for the project which includes but is not limited to the following: a. Proposed construction worker parking area. b. Proposed construction hours that are consistent with City Code. 138 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 5 c. Proposed construction/delivery vehicle staging or parking areas. d. Proposed traffic control plan with traffic control measures, any street closure, hours for delivery/earth moving or hauling, etc. To the extent possible, any deliveries, earth moving or hauling activities will be scheduled to avoid peak commute hours. e. Proposed construction material staging/storage areas. f. Location of project construction sign outlining permitted construction work hours, name of project contractor and the contact information for both homeowner and contractor. 11. All fences, walls and hedges shall conform to height requirements provided in City Code Section 15-29. 12. The final landscaping and irrigation plan submitted for Building Permit approval shall demonstrate how the project complies with the State Water Efficient Landscape Ordinance and shall consider the following: a. To the extent feasible, landscaping shall be designed and operated to treat storm water runoff by incorporating elements that collect, detain and infiltrate runoff. In areas that provide detention of water, plants that are tolerant of saturated soil conditions and prolong exposure to water shall be specified. b. To the extent feasible, pest resistant landscaping plants shall be used throughout the landscaped area, especially along any hardscape area. c. Plant materials selected shall be appropriate to site specific characteristics such as soil type, topography, climate, amount and timing of sunlight, prevailing winds, rainfall, air movement, patterns of land use, ecological consistency, and plant interactions to ensure successful establishment. d. Pest resistant landscaping plants shall be considered for use throughout the landscaped area, especially along any hardscape area. e. Any proposed or required under grounding of utilities shall consider potential damage to roots of protected trees 13. Front yard landscaping shall be installed prior to final inspection or a bond satisfactory to the Community Development Department valued at 150% of the estimated cost of the installation of such landscaping shall be provided to the City. 14. A locking mailbox approved for use by the U.S. Postal service shall be installed and in compliance with Saratoga Municipal Code section 6-25.030. The mailbox shall be installed prior to final inspection. 15. A Building Permit must be issued, and construction commenced within 36 months from the date of adoption of this Resolution or the Design Review Approval will expire unless extended in accordance with the City Code. 16. The pool equipment is not to be located in a side setback area. Pools and pool equipment are subject to the regulations contained in City Code Section 15-80.030(b). 139 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 6 17. West Valley Collection & Recycling is the exclusive roll-off and debris box provider for the City of Saratoga. To schedule delivery of a debris box, contact West Valley Collection & Recycling at 408-283-9250 or customerservice@westvalleyrecycles.com FIRE DEPARTMENT 18. The owner/applicant shall comply with all Fire Department requirements. ARBORIST 19. All requirements in the City Arborist Report dated July 21, 2022 are hereby adopted as conditions of approval and shall be implemented as part of the approved plans. Payment of the Tree Protection Security Deposit and installation and inspection by the City Arborist of the tree protection fencing shall be completed prior to issuance of a demolition or building permit. ENGINEERING 20. The owner/applicant shall comply with all City requirements regarding drainage, including but not limited to complying with the city approved Stormwater management plan. The project shall retain and/or detain any increase in design flow from the site, that is created by the proposed construction and grading project, such that adjacent down slope properties will not be negatively impacted by any increase in flow. Design must follow the current Santa Clara County Drainage Manual method criteria, as required by the building department. Retention/detention element design must follow the Drainage Manual guidelines, as required by the building department. 21. Applicant / Owner shall obtain an encroachment permit for any and all improvements in any City right-of-way or City easement including all new utilities prior to commencement of the work to implement this Design Review. 22. Per Design Review PDR21-0023, no improvements in the public right-of-way are required. 23. Damages to driveway approach, curb and gutter, public streets, or other public improvements during construction shall be repaired prior to final inspection. 24. All new/upgraded utilities shall be installed underground. 25. Applicant / Owner shall maintain the streets, sidewalks and other right of way as well as adjacent properties, both public and private, in a clean, safe and usable condition. All spills of soil, rock or construction debris shall be removed immediately. 26. The Owner/Applicant shall incorporate adequate source control measures to limit pollutant generation, discharge, and runoff (e.g., landscaping that minimizes irrigation and runoff, promotes surface infiltration where possible, minimizes the use of pesticides and fertilizers, and incorporates appropriate sustainable landscaping practices and programs, such as Bay-Friendly Landscaping). 27. All building and construction related activities shall adhere to New Development and Construction – Best Management Practices as adopted by the City for the purpose of preventing 140 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 7 storm water pollution: • Owner shall implement construction site inspection and control to prevent construction site discharges of pollutants into the storm drains per approved Erosion Control Plan. • The City requires the construction sites to maintain year-round effective erosion control, run-on and run-off control, sediment control, good site management, and non-storm water management through all phases of construction (including, but not limited to, site grading, building, and finishing of lots) until the site is fully stabilized by landscaping or the installation of permanent erosion control measures. • City will conduct inspections to determine compliance and determine the effectiveness of the BMPs in preventing the discharge of construction pollutants into the storm drain. Owner shall be required to timely correct all actual and potential discharges observed. 28. Prior to the commencement of any earthwork/grading activities, the permittee shall arrange a pre-construction meeting. The meeting shall include the City of Saratoga Grading Inspector (408-868-1201), the grading contractor, and the project Soils Engineer. The permittee or representative shall arrange the pre-construction meeting at least 48 hours prior to the start of any earthwork activities. 29. Prior to foundation inspection by the City, the LLS of record shall provide a written certification that all building setbacks are per the approved plans. 30. Prior to the Building final, all Public Works conditions shall be completed per approved plans. 31. Upon the completion of this project the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the City's building inspector to be properly elevated. Such certification and verification shall be provided to the City’s Floodplain Administrator. 32. Geotechnical Plan Review- The Project Geotechnical Consultant shall review and approve all geotechnical aspects of the final development plans (i.e., site preparation and grading, site surface and subsurface drainage improvements and design parameters for retaining walls, and foundations including the recommended deepened footings, etc.,) to ensure that the plans, specifications and details accurately reflect the consultants’ recommendations. The results of the plan review shall be summarized by the Project Geotechnical Consultant in a letter and submitted to the City Engineer for review prior to issuance of building permits. 33. Geotechnical Construction Inspection - The Project Geotechnical Engineer shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections shall include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, foundation construction, prior to placement of steel and concrete. The Consultant should inspect the retaining wall and foundation excavations for conformance with their recommendations and anticipated site conditions 141 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 8 The results of these inspections and the as-built conditions of the project shall be described by the Project Geotechnical Engineer in a letter(s) and submitted to the City Engineer for review and approval prior to Final (as-built) Project Approval. 34. The owner (applicant) shall pay any outstanding fees associated with the City Geotechnical Consultant’s review of the project prior to Zone Clearance. 35. The owner (applicant) shall enter into an Indemnity Agreement holding the City of Saratoga harmless from any claims or liabilities caused by or arising out of soil or slope instability, slides, slope failure or other soil related and/or erosion related conditions. BUILDING DEPARTMENT SUBMITTAL 36. Complete construction plans shall be submitted to the Building Division. These plans shall be subject to review and approval by the City prior to issuance of Zoning Clearance. The construction plans shall, at a minimum include the following: a. Architectural drawings and other plan sheets consistent with those identified as Exhibit “A” on file with the Community Development Department. b. All additional drawings, plans, maps, reports, notes, and/or materials required by the Building Division. c. This signed and dated Resolution printed onto separate construction plan pages. 142 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 9 Exhibit 2 DESIGN REVIEW FINDINGS PDR21-0023 / ARB21-0084 19518 GLEN UNA DRIVE (APN 510-06-066) The findings required for issuance of Design Review approval pursuant to City Code Section 15- 45.080 are set forth below. a. Site development follows the natural contours of the site, minimizes grading, and is appropriate given the property’s natural constraints. This finding can be made in the affirmative in that the project minimizes changes to the contours of the site. Grading will be primarily limited to expanding the size of the existing building pad to accommodate the first story addition and creating level areas for the detached cabana, pool, and related decking and walkways. b. All protected trees shall be preserved, as provided in Article 15-50 (Tree Regulations). If constraints exist on the property, the number of protected trees, heritage trees, and native trees approved for removal shall be reduced to an absolute minimum. Removal of any smaller oak trees deemed to be in good health by the City Arborist shall be minimized using the criteria set forth in Section 15-50.080. This finding can be made in the affirmative in that the number of trees to be removed is limited to three trees which were evaluated by the City Arborist to be deceased or conflict with the location of the fire truck turnaround area. Tree protection fencing is required to be installed prior to the issuance of building permits and shall remain in place for project duration. The height of the structure, its location on the site, and its architectural elements are designed to avoid unreasonable impacts to the privacy of adjoining properties and to community viewsheds. This finding can be made in the affirmative in that the second story windows facing the neighboring property owners are relatively few in number and smaller in size. Privacy impacts of the roof terraces are mitigated by the views being directed toward Glen Una Drive and the rear yard with the distance to nearest rear residence being greater than 350 feet. Existing landscaping along the perimeter of the site offers additional privacy screening. No community view sheds are in the vicinity of the project. The overall mass and height of the structure, and its architectural elements are in scale with the structure itself and with the neighborhood. This finding can be made in the affirmative in that the second story has a proposed height that does not exceed the maximum allowable height for a single-family residence and proposed setbacks that are greater than the minimum required by the zoning district. The second story windows on the second floor and relatively few in number, small in size, and the distance from both the adjacent residences and existing landscaping along the property lines will help mitigate privacy impacts. No community viewsheds are located in the vicinity of the project. to reduce the perception of mass. The architectural elements of the structure are true to the Spanish Revival style with architectural forms and detailing to reduce the perception of mass. c. 143 19518 Glen Una Drive– Application # PDR21-0023 / ARB22-019 October 12, 2022 Page | 10 d. The landscape design minimizes hardscape in the front setback area and contains elements that are complementary to the neighborhood streetscape. This finding can be made in the affirmative in that the hardscape within the 30-foot front setback area containing existing trees and ornamental landscaping that complement the neighborhood streetscape. The existing asphalt driveway will be removed and replaced with permeable pavers. e. Development of the site does not unreasonably impair the ability of adjoining properties to utilize solar energy. This finding can be made in the affirmative in that the development will not unreasonably impair the ability of adjoining properties to utilize solar energy as the tallest elements of the structure are located at the center of the site to minimize shadowing, the project meets or exceeds required setbacks, and the orientation of the sun with respect to the location of the site will not cast shadows on adjoining properties. f. The design of the structure and the site development plan is consistent with the Residential Design Handbook, pursuant to Section 15-45.055. This finding can be made in the affirmative because the proposed project incorporates applicable design policies and techniques from the Residential Design Handbook. The overall mass and height of the structure are in scale with the neighborhood; the structure is set back in proportion to the size and shape of the lot; site development follows contours and is appropriate given the property’s natural constraints. In addition, the proposed materials, colors, and details enhance the architecture in a well-composed, understated manner. g. On hillside lots, the location and the design of the structure avoid unreasonable impacts to ridgelines, significant hillside features, community viewsheds, and is in compliance with Section 15-13.100. The lot is not zoned Hillside Residential but does have an average slope in excess of 10% so it is classified as a hillside lot. There are no ridgelines, community viewsheds, or significant hillside features in the vicinity of the project. The project is also compliant with the residential structure height limits contained within Section 15-13.100. 144 Community Development Department 13777 Fruitvale Avenue Saratoga, CA 95070 www.saratoga.ca.us/171/trees 408.868.1276 CITY OF SARATOGA ARBORIST APPROVAL Conditions of Approval and Tree Protection Plan Prepared by Christina Fusco, City Arborist Application No. ARB21-0084 Phone: (408) 868-1276 Address: 19518 Glen Una Drive Email: cfusco@saratoga.ca.us Owner: Sanjay & Anuja Banerjee APN: 510-06-066 Date: July 21, 2022 PROJECT SCOPE: The applicant has submitted plans to add on to the existing home and construct a pool and cabana. Four trees are requested for removal to construct the project. PROJECT DATA IN BRIEF: Tree security deposit – Required - $131,060 Tree protection – Required – See Conditions of Approval and attached map. Tree removals – Trees #1, 14, 57, and 58 are approved for removal once building permits have been issued. Replacement trees – Required = $4,400 ATTACHMENTS: 1 – Findings and Tree Information 2 – Tree Removal Criteria 3 – Conditions of Approval 4 – Map Showing Tree Protection 1 of 12 145 19518 Glen Una Drive Attachment 1 FINDINGS: Tree Removals According to Section 15-50.080 of the City Code, whenever a tree is requested for removal as part of a project, certain findings must be made and specific tree removal criteria met. Four trees are in conflict with the project, and meet the City’s criteria allowing them to be removed and replaced as part of the project, once building division permits have been obtained. Attachment 2 contains the tree removal criteria for reference. Table 1: Summary of Tree Removal Criteria that are met Tree No. Species Criteria met Comments 1 Deodar cedar Cedrus deodara 1, 4, 6 Dead 14 Coast live oak Quercus agrifolia 4, 6, 9 In conflict with fire truck turnaround 57 Camphor Cinnamomum camphora 2, 4, 6, 8, 9, 11 In conflict with fire truck turnaround 58 Ficus Ficus Spp. 2, 4, 6, 8, 9, 11 In conflict with fire truck turnaround New Construction Based on the information provided, and as conditioned, this project complies with the requirements for the setback of new construction from existing trees under Section 15- 50.120 of the City Code. Tree Preservation Plan Section 15-50.140 of the City Code requires a Tree Preservation Plan for this project. To satisfy this requirement the following shall be copied onto a plan sheet and included in the final sets of plans: 1)The tree information, recommendations, and map showing tree protection from the submitted arborist report dated May 22, 2022. 2)The Project Data in Brief and the Conditions of Approval from this report dated July 21, 2022. TREE INFORMATION: Project Arborist: David Laczko Date of Report: May 22, 2022 Number of protected trees inventoried: 29 Number of protected trees requested for removal: 4 A table summarizing information about each tree is below. 2 of 12 146 Tree #Common Name Species DBH (in.)Spread (ft.) Condition (0-5)Suitability Impacts Disposition TPZ Radius (ft.) 1 Deodar Cedar Cedrus deodara 42 50 DEAD Low NA Remove NA 2 Camphor Cinnamomum camphora 9, 12.8, 12.6 25 3 Moderate Negligible Retain Planting bed. 5 Coast Live Oak Quercus agrifolia 10.3 25 4 High Negligible Retain Planting bed. 6 Coast Live Oak Quercus agrifolia 8.7 20 4 High Negligible Retain Planting bed. 7 Coast Live Oak Quercus agrifolia 17 35 4 High Negligible Retain Planting bed. 8 Coast Live Oak Quercus agrifolia 9.5 15 4 High Negligible Retain Planting bed. 11 Coast Live Oak Quercus agrifolia 13.8 25 4 High Negligible Retain Planting bed. 12 Coast Live Oak Quercus agrifolia 8.7 25 4 High Negligible Retain Planting bed. 13 Camphor Cinnamomum camphora 13.3, 17.3, 11.6, 20.2, 8, 15.5, 18.8 60 3 High Negligible Retain Planting bed. 14 Coast Live Oak Quercus agrifolia 8.2 15 4 High Impedes Fire Dept.Remove NA 15 Coast Live Oak Quercus agrifolia 14.7 35 4 High Negligible Retain Planting bed. 15a Southern Magnolia Magnolia grandiflora 21, 9, 9 25 4 High Root loss Retain Monitor 16 Coast Live Oak Quercus agrifolia 16 30 4 High Direct impacts, root loss Retain Type III TPZ 17 Coast Live Oak Quercus agrifolia 14.2 30 4 High Direct impacts, root loss Retain Type III TPZ 18 Coast Live Oak Quercus agrifolia 20.2 35 4 High Direct impacts, root loss Retain Type III TPZ 19 Coast Live Oak Quercus agrifolia 39 @ 24 60 4 High Direct impacts, root loss Retain 30 20 Coast Redwood Sequoia sempervirens 8 10 4 High Negligible Retain Drip-line 21 Coast Redwood Sequoia sempervirens 7.5 10 4 High Negligible Retain Drip-line 27 Coast Live Oak Quercus agrifolia 42.8 @ 36 75 4 High Direct impacts, root loss Retain 15, 20 28 Sycamore Platanus racemosa 28.5, 25.8, 22.4, 10.7, 12, 26.5, 12, 33.3, 30.6 100 3 Moderate Direct impacts, root loss Retain 20, Dripline 45 Coast Live Oak Quercus agrifolia 33.4 @ 36 80 4 High Direct impacts, root loss Retain 25 46 Coast Live Oak Quercus agrifolia 43.6 @ grade 100 4 High Direct impacts, root loss Retain 25 52 Coast Live Oak Quercus agrifolia 37.6 70 4 High Direct impacts, root loss Retain 27.25 53 Privet Ligustrum lucidum 20.2 25 3 Low Direct impacts, root loss Retain Drip-line Appendix A: Tree Table Prepared by Dave Laczko for Anuja Banerjee 3 of 12 147 Tree #Common Name Species DBH (in.)Spread (ft.) Condition (0-5)Suitability Impacts Disposition TPZ Radius (ft.) 54 Privet Ligustrum lucidum 11 15 3 Low Direct impacts, root loss Retain Drip-line 55 Deodar Cedar Cedrus deodara 41.1 50 4 High Direct impacts, root loss Retain 25 56 Japanese Maple Acer palmatum 11.2, 11.3, 9.1 35 3 High Direct impacts, root loss Retain 4, 10 57 Camphor Cinnamomum camphora 11.2, 7.5 30 3 Moderate Direct impacts, root loss Remove NA 58 Ficus Ficus spp.25.5 @ grade 30 4 Moderate Direct impacts, root loss Remove NA Prepared by Dave Laczko for Anuja Banerjee 4 of 12 148 Tree #Common Name DBH (in.)Species Rating % Condition Rating % Functional Limit % External Limit % Appraised Value 1 Deodar Cedar 42 90 DEAD 50 65 $0 2 Camphor 9, 12.8, 12.6 70 50 50 65 $3,000.00 5 Coast Live Oak 10.3 90 50 50 65 $640.00 6 Coast Live Oak 8.7 90 50 50 65 $480.00 7 Coast Live Oak 17 90 65 50 65 $2,100.00 8 Coast Live Oak 9.5 90 65 50 65 $720.00 11 Coast Live Oak 13.8 90 65 50 65 $1,400.00 12 Coast Live Oak 8.7 90 65 50 65 $620.00 13 Camphor 13.3, 17.3, 11.6, 20.2, 8, 15.5, 18.8 70 40 40 65 $7,700.00 14 Coast Live Oak 8.2 90 50 50 65 $440.00 15 Coast Live Oak 14.7 90 65 50 65 $1,600.00 15a Southern Magnolia 21, 9, 9 90 75 65 65 $6,600.00 16 Coast Live Oak 16 90 65 50 65 $1,800.00 17 Coast Live Oak 14.2 90 75 50 65 $1,700.00 18 Coast Live Oak 20.2 90 65 50 65 $2,900.00 19 Coast Live Oak 39 @ 24 90 70 60 65 $12,500.00 20 Coast Redwood 8 90 75 65 65 $680.00 21 Coast Redwood 7.5 90 75 65 65 $620.00 27 Coast Live Oak 42.8 @ 36 90 60 65 65 $13,300.00 28 Sycamore 28.5, 25.8, 22.4, 10.7, 12, 26.5, 12, 33.3, 30.6 70 41 45 65 $15,700.00 45 Coast Live Oak 33.4 @ 36 90 70 65 65 $10,200.00 46 Coast Live Oak 43.6 @ grade 90 70 65 65 $16,000.00 52 Coast Live Oak 37.6 90 65 65 65 $12,100.00 Appendix B: Tree Appraisals Prepared by Dave Laczko for Anuja Banerjee 5 of 12 149 Tree #Common Name DBH (in.)Species Rating % Condition Rating % Functional Limit % External Limit % Appraised Value 53 Privet 20.2 30 65 65 65 $1,200.00 54 Privet 11 30 65 65 65 $400.00 55 Deodar Cedar 41.1 90 65 61 65 $13,000.00 56 Japanese Maple 11.2, 11.3, 9.1 70 65 65 65 $4,100.00 57 Camphor 11.2, 7.5 70 65 55 65 $2,000.00 58 Ficus 25.5 @ grade 30 65 65 65 $1,960.00 $135,460 $4,400.00 $131,060.00 Total Combined Tree Appraised Values: Total Tree Replacment Value: Total Required Tree Security Deposit: Prepared by Dave Laczko for Anuja Banerjee 6 of 12 150 19518 Glen Una Drive Attachment 2 TREE REMOVAL CRITERIA Criteria that permit the removal of a protected tree are listed below. This information is from Article 15-50.080 of the City Code and is applied to any tree requested for removal as part of the project. If findings are made that meet the criteria listed below, the tree(s) may be approved for removal and replacement during construction. (1) The condition of the tree with respect to disease, imminent danger of falling, proximity to existing or proposed structures and interference with utility services, and whether the tree is a Dead tree or a Fallen tree. (2) The necessity to remove the tree because of physical damage or threatened damage to improvements or impervious surfaces on the property. (3) The topography of the land and the effect of the tree removal upon erosion, soil retention and the diversion or increased flow of surface waters, particularly on steep slopes. (4) The number, species, size and location of existing trees in the area and the effect the removal would have upon shade, privacy impact, scenic beauty, property values, erosion control, and the general welfare of residents in the area. (5) The age and number of healthy trees the property is able to support according to good forestry practices. (6) Whether or not there are any alternatives that would allow for retaining or not encroaching on the protected tree. (7) Whether the approval of the request would be contrary to or in conflict with the general purpose and intent of this Article. (8) Any other information relevant to the public health, safety, or general welfare and the purposes of this ordinance as set forth in Section 15-50.010 (9) The necessity to remove the tree for economic or other enjoyment of the property when there is no other feasible alternative to the removal. (10) The necessity to remove the tree for installation and efficient operation of solar panels, subject to the requirements that the tree(s) to be removed, shall not be removed until solar panels have been installed and replacement trees planted in conformance with the City Arborist's recommendation. (11) The necessity to remove a tree following the creation of defensible space within 100 feet of a structure located within the Wildland Urban Interface, in accordance with defensible space standards established by CAL FIRE or as determined by Santa Clara County Fire Department, and that risk of increased wildfire cannot reasonably be addressed through maintenance or without tree removal. 7 of 12 151 19518 Glen Una Drive Attachment 3 CONDITIONS OF APPROVAL 1. Owner, Architect, Contractor: It is the responsibility of the owner, architect, and contractor to be familiar with the information in this report and implement the required conditions. 2. Permit: a. Receipt of a Planning or Building permit does not relieve applicant of his responsibilities for protecting trees per City Code Article 15-50 on all construction work. b. No protected tree authorized for removal or encroachment pursuant to this project may be removed or encroached upon until the issuance of the applicable permit from the building division for the approved project. 3. Final Plan Sets: a. Shall include the tree information, protection recommendations, and the map showing tree protection from the arborist report by David Laczko dated May 22, 2022 copied onto a plan sheet. b. Shall include the Project Data in Brief and the Conditions of Approval sections of the City Arborist report dated July 21, 2022. 4. Tree Protection Security Deposit: a. Is required per City Ordinance 15-50.080. b. Shall be $131,160 for tree(s) 2, 5-8, 11-13, 15-21, 27, 28, 45, 46, 52-56. c. Shall be obtained by the owner and filed with the Community Development Department before obtaining Building Division permits. d. May be in the form of cash, check, or a bond. e. Shall remain in place for the duration of construction of the project. f. May be released once the project has been completed, inspected and approved by the City Arborist. 5. Tree Protection Fencing: a. Shall be installed as shown on the attached map. b. Shall be shown on the Site Plan. c. Shall be established prior to the arrival of construction equipment or materials on site. d. Shall be comprised of six-foot high chain link fencing mounted on 2-inch diameter galvanized posts, driven into the ground and spaced no more than 10 feet apart. e. Shall be posted with signs saying, “TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT APPROVAL FROM CITY ARBORIST, CHRISTINA FUSCO (408) 868- 1276”. f. Call City Arborist, Christina Fusco at (408) 868-1276 for an inspection of tree protection fencing once it has been installed. This is required prior to obtaining building division permits. g. Tree protection fencing shall remain undisturbed throughout the construction until final inspection. 8 of 12 152 19518 Glen Una Drive Attachment 3 6. Construction: All construction activities shall be conducted outside tree protection fencing unless permitted as conditioned below. These activities include, but are not necessarily limited to, the following: demolition, grading, trenching for utility installation, equipment cleaning, stockpiling and dumping materials (including soil fill), and equipment/vehicle operation and parking. 7. Work inside fenced areas: a. Requires a field meeting and approval from City Arborist before performing work. b. Requires Project Arborist on site to monitor work. 8. Project Arborist: a. Shall be David Laczko unless otherwise approved by the City Arborist. b. Shall visit the site every two weeks during grading, trenching or digging activities and every six weeks thereafter. A letter/email shall be provided to the City after each inspection which documents the work performed around trees, includes photos of the work in progress, and provides information on tree condition during construction. c. Shall supervise any permitted pruning or root pruning of trees on site. Roots of protected trees measuring two inches in diameter or more shall not be cut without prior approval of the Project Arborist. 9. Tree removal: Trees #1, 14, 57, and 58 meet the criteria for removal and may be removed once building division permits have been obtained. 10. New trees: a. New trees equal to $4,400 shall be planted as part of the project before final inspection and occupancy of the new home. New trees may be of any species and planted anywhere on the property as long as they do not encroach on retained trees. Replacement values for new trees are listed below. 15 gallon = $350 24 inch box = $500 36 inch box = $1,500 48 inch box = $5,000 60 inch box = 7,000 72 inch box = $15,000 b. Trees shall be replaced on or off site according to good forestry practices and shall provide equivalent value in terms of aesthetic and environmental quality, size, height, location, appearance and other significant beneficial characteristics of the removed trees. 11. Damage to protected trees that will be retained: a. Should any protected tree be damaged beyond repair, new trees shall be required to replace the tree. If there is insufficient room to plant the necessary number of new trees, some of the value for trees may be paid into the City’s Tree Fund. b. Water loving plants and lawns are not permitted under oak tree canopies. Only drought tolerant plants that are compatible with oaks are permitted under the outer half of the canopy of oak trees on site. 9 of 12 153 19518 Glen Una Drive Attachment 3 12. Final inspection: At the end of the project, when the contractor wants to remove tree protection fencing and have the tree protection security deposit released by the city, call City Arborist for a final inspection. Before scheduling a final inspection from the City Arborist, have the project arborist do an inspection, prepare a letter with their findings, and provide that letter to the city for the project file. 10 of 12 154 N E S WTPZ MAP - NORTH 19518 Glen Una Drive Saratoga, CA 95070 #19 #6 #7 #15 #20 #52 #55 #56 #15A #1 #2 #5 #8 #11 #12 #13 #57 #58 #21#22 #53 #54 #16#17 #18 #14 After the demolition of the existing garage, create a path used for movement of materials and equipment related to the construction of the pool and cabana. TPZ MAP LEGEND Prepared by Dave Laczko for Anuja Banerjee 19 Appendix C: TPZ Map - North 1911 of 12155 TPZ MAP LEGEND N E S W TPZ MAP - SOUTH 19518 Glen Una Drive Saratoga, CA 95070 Appendix D: TPZ Map - South Prepared by Dave Laczko for Anuja Banerjee2012 of 12156 157 158 159 160 RESIDENTIAL PROJECT AT: 19518 GLEN UNA DR. SARATOGA, CA 95070 MATERIAL BOARD TRIM COLOR: Swiss Coffee KM23 COLOR By: “Kelly Moore” ROOF Mission Tiles by: MCA or simila COLOR: B330 - Old Santa Barbara Bassal Architecture, 4912 Bradford Place, Rocklin, CA 95765 (916) 435-0605 / (408) 674-2077 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 LOCATION MAP LEGEND SHEET INDEX: SITE CONSTRUCTION MANAGEMENT NOTES: UNDERGROUND UTILITIES: GEOTECHNICAL ENGINEER FIELD REPORT: UTILITY NOTES: GENERAL PROJECT NOTES: STANDARD GRADING NOTES:WORK IN PUBLIC RIGHT OF WAY: GEOTECHNICAL REVIEW: NOTE: BASIS OF ELEVATIONS BASIS OF BEARINGS: SMP ENGINEERS SURVEY MAP DISCLAIMER NOTE: EARTHWORK TABLE 186 187 188 SMP ENGINEERS ROOF DOWNSPOUT/SPLASH BLOCK SUBDRAIN TRENCH DETAIL X PLAN Y X Y SECTION Y-YSECTION X-X STORM DRAIN INLET ELEVATION VIEW STORM DRAIN CLEANOUT DETAIL STORM DRAIN AREA DRAIN SECTION W-W W PLAN Z W SECTION Z-Z EARTH SWALE DETAIL Z V-DITCH ON-SITE VERTICAL CURB ROOF DOWN-SPOUT CONNECTION INLET/ DRYWELL/ DETAIL 189 SMP ENGINEERS 190 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx x x x xx xxxxxxxx 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 28 4526 27 25 24 12 4 10 11 12 131415 15 16 16 5556 54 53 5657 58 17 18 52 51 5049 48 47 19 20 21 22 23 46 5 6 7 89 A A A PLAN VIEW SECTION A - A STORM INLET SEDIMENT TRAP-FIBER ROLLS CONCRETE WASHOUT AREA EROSION AND SEDIMENT CONTROL NOTES AND MEASURES EXISTING DRAINAGE INLET PROTECTION PLAN FIBER ROLL NOTES FIBER ROLL SECTION B-B TEMPORARY COVER ON STOCK PILE PERSPECTIVE STABILIZED CONSTRUCTION ENTRANCE (TO BE MAINTAINED) Maintenance PLAN PROFILE SMP ENGINEERS 191 SMP ENGINEERS 192 SMP ENGINEERS 193